Home/Catalog/Wellfleet-SWSMDS-MIB

Wellfleet-SWSMDS-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

158
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

158 total
Object Name
RFC1155-SMIThe Wellfleet SMDS Switch Circuit (SNI, subscriber) Record. This record holds information on a per circuit (SSI, SNI, subscriber) basis.
SEQUENCE OF WfSmdsSwSubEntry
.1.3.6.1.4.1.18.3.5.9.7.1
wfSmdsSwEndpTableThe Parameters for the Endpoint table. An Endpoint is defined as an IP address, SMDS E.164 address pair. Endpoint ranges should never overlap.
SEQUENCE OF WfSmdsSwEndpEntry
.1.3.6.1.4.1.18.3.5.9.7.2
wfSmdsSwEndpEntryThe parameters for a particular Endpoint.
WfSmdsSwEndpEntry
.1.3.6.1.4.1.18.3.5.9.7.2.1
wfSmdsSwEndpDeleteIndication to delete this endpoint entry.rw
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.2.1.1
wfSmdsSwEndpE164AddrHighThe High end of the E.164 address range for this endpoint information.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.2.1.2
wfSmdsSwEndpE164AddrDeltaThe difference between wfSmdsSwEndpE164AddrHigh to the beginning of the endpoint information.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.2.1.3
wfSmdsSwEndpInterfaceIndexThis number indicates which SNI the endpoint information refers to.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.2.1.4
wfSmdsSwInterfaceTableThis is the Interface Table. This table also holds the Maximum Information Rate (MIR) information.
SEQUENCE OF WfSmdsSwInterfaceEntry
.1.3.6.1.4.1.18.3.5.9.7.3
wfSmdsSwInterfaceEntryThis table defines the IP addresses and what interfaces they are associated with.
WfSmdsSwInterfaceEntry
.1.3.6.1.4.1.18.3.5.9.7.3.1
wfSmdsSwInterfaceDeleteIndication to delete this interface entry.rw
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.3.1.1
wfSmdsSwInterfaceTypeThis number determines whether the interface information refers to an SNI, SSI, or ICI.ro
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.3.1.2
wfSmdsSwInterfaceIndexThis number indicates which SNI, SSI, or ICI the interface information refers to.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.3.1.3
wfSmdsSwInterfaceIpAddrIP Address associated with the interface.rw
IpAddress
.1.3.6.1.4.1.18.3.5.9.7.3.1.4
wfSmdsSwInterfaceMIRThis number represents the MIR in octets per second.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.3.1.5
wfSmdsSwInterfaceCurrentRateThis number indicates the current rate of traffic flow to the interface. The software updates this counter. When this attribute exceeds wfSmdsSwInterfaceMIR traffic to the interface is dropped. Periodically the sofware resets this counter to zero.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.3.1.6
wfSmdsSwAssocScrnTableThis list identifies the associated SNI addresses per individualand group address screen. Different addresses on an SNI may be associated with different individual and group address screens (one individual address screen per associated address on an SNI, and one group address screen per associated address on an SNI ).
SEQUENCE OF WfSmdsSwAssocScrnEntry
.1.3.6.1.4.1.18.3.5.9.7.4
wfSmdsSwAssocScrnEntryAn SNI index, group and individual screening list index, and the associated addresses for the SNI for the address screens.
WfSmdsSwAssocScrnEntry
.1.3.6.1.4.1.18.3.5.9.7.4.1
wfSmdsSwAssocScrnDeleteIndication to delete this associated screen entry.rw
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.4.1.1
wfSmdsSwAssocScrnSniIndexThe value of this object identifies the SIP Port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex, defined in RFC1213, for the same interface.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.4.1.2
wfSmdsSwAssocScrnAddrIndThe value of this object identifies one of the SMDS addresses for the SNI, identified by the wfSmdsSwAssocScrnSniIndex that belongs to this individual (or group) address screen (wfSmdsSwAssocScrnAddrInd). This list will contain both individual and group addresses, because this list is used for both Destination Address Screening and Source Address Screening; the destination address in the L3_PDU that is undergoing Source Address Screening may be either a group or individual address that is assigned to that SNI. One screen will have a maximum of 64 associated addresses; up to a maximum of 16 individual addresses identifying an SNI and up to a maximum of 48 group addresses identifying an SNI.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.4.1.3
wfSmdsSwAssocScrnIndivIndexThe value of this object identifies the individual address screening list. There is at least one individual address screen and at most s individual address screens per SNI. The initial value of s is defined to be 4. In the future more screening lists per SNI may be allowed. The values of this object correspond to the values of wfSmdsSwIAScrnIndex in the wfSmdsSwIAScrnTable.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.4.1.4
wfSmdsSwAssocScrnGrpIndexThe value of this object identifies the group address screening list. There is at least one group address screen and at most s group address screens per SNI. The initial value of s is defined to be 4. In the future more screening lists per SNI may be allowed. The values of this object correspond to the values of wfSmdsSwGAScrnIndex in the wfSmdsSwGAScrnTable. This field applies only to individual addresses on the SNI because it applies only to destination address screening of group addresses.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.4.1.5
wfSmdsSwIAScrnTableThis list identifies the individual addresses that will be screened per individual address screen table. The are up to s (s is equal to 4) individual address screens per SNI and at least one individual address screen per SNI. The Individual Address Screens and the Group Address Screens together consist of up to n addresses. The initial value of n is defined as 128. In the future a value of n up to 2048 may be supported. The Individual Address Screen is used to perform Destination Address Screening for individually addressed data units and Source Address Screening for all data units. The Group Address Screen is used to perform Destination Address Screening for group addressed data units.
SEQUENCE OF WfSmdsSwIAScrnEntry
.1.3.6.1.4.1.18.3.5.9.7.5
wfSmdsSwIAScrnEntryAn SNI index, a screening list index, the individual addresses to be screened for the individual address screen, and whether the screened address is valid or invalid.
WfSmdsSwIAScrnEntry
.1.3.6.1.4.1.18.3.5.9.7.5.1
wfSmdsSwIAScrnDeleteIndication to delete this IA screen entry.rw
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.5.1.1
wfSmdsSwIAScrnSniIndexThe value of this object identifies the SIP Port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex, defined in RFC1213, for the same interface.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.5.1.2
wfSmdsSwIAScrnIndexThe value of this object identifies the individual address screening list. There are at least one individual address screen and at most s individual address screens per SNI. The initial value of s is defined to be 4. In the future more screening lists per SNI may be allowed. The values of this object correspond to the values of wfSmdsSwScrnIndex in the wfSmdsSwScrnTable.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.5.1.3
wfSmdsSwIAScrnAddrThe value of this object identifies one of the individual addresses to be screened for source and destination address screening for the SNI identified by the wfSmdsSwIAScrnSniIndex and for the particular individual address screen (wfSmdsSwIAScrnIndex).ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.5.1.4
wfSmdsSwGAScrnTableThis list identifies the group addresses that will be screened per group address screen table. The are up to s (s is equal to 4) group address screens per SNI and at least one group address screen per SNI. The Individual Address Screen and the Group Address Screen together consist of up to n addresses. The initial value of n is defined as 128. In the future a value of n up to 2048 may be supported. The Individual Address Screen is used to perform Destination Address Screening for individually addressed data units and Source Address Screening for all data units. The Group Address Screen is used to perform Destination Address Screening for group addressed data units.
SEQUENCE OF WfSmdsSwGAScrnEntry
.1.3.6.1.4.1.18.3.5.9.7.6
wfSmdsSwGAScrnEntryAn SNI index, a screening list index, the group addresses to be screened for the group address screen, and whether the screened address is valid or invalid.
WfSmdsSwGAScrnEntry
.1.3.6.1.4.1.18.3.5.9.7.6.1
wfSmdsSwGAScrnDeleteIndication to delete this GA screen entry.rw
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.6.1.1
wfSmdsSwGAScrnSniIndexThe value of this object identifies the SIP Port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex, defined in RFC1213, for the same interface.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.6.1.2
wfSmdsSwGAScrnIndexThe value of this object identifies the group address screening list. There is at least one group address screen and at most s group address screens per SNI. The initial value of s is defined to be 4. In the future more screening lists per SNI may be allowed. The values of this object correspond to the values of wfSmdsSwScrnIndex in the wfSmdsSwSmdsScrnTable.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.6.1.3
wfSmdsSwGAScrnAddrThe value of this object identifies one of the group addresses to be screened for destination address screening for the SNI identified by the wfSmdsSwGAScrnSniIndex and for the particular group address screen (wfSmdsSwGAScrnIndex).ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.6.1.4
wfSmdsSwGATableA table of all group addresses in the network and the associated individual addresses identified by each group address. A group address identifies up to m individual addresses. An SMDS SS supports up to n group addresses. A group address can be identified by up to p individual addresses. A particular SNI is identified by up to 48 group addresses. The initial values of m, n, and p are defined as 128, 1024, and 32, respectively. In the future values of m and n of 2048 and 8192, respectively, may be supported.
SEQUENCE OF WfSmdsSwGAEntry
.1.3.6.1.4.1.18.3.5.9.7.7
wfSmdsSwGAEntryA Group Address and an address in that group and whether that association is valid or invalid.
WfSmdsSwGAEntry
.1.3.6.1.4.1.18.3.5.9.7.7.1
wfSmdsSwGADeleteIndication to delete this group address entry.rw
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.7.1.1
wfSmdsSwGASSIThe SSI associated with this Group Address. An SSI of 0 is used to indicate that all interfaces can use the group address. An SSI other than 0 indicates that only the SSI, or an SNI associated with the SSI should use the group.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.7.1.2
wfSmdsSwGAGroupAddressA Group Address.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.7.1.3
wfSmdsSwGAGroupMemberAn individual SMDS address that belongs to this Group Address.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.7.1.4
wfSmdsSwCurUsageTableThis table contains the Current Usage Data. This is the interface between Billing and Switching. The Switch gates create these records. The Billing gates collect them to create billing data.
SEQUENCE OF WfSmdsSwCurUsageEntry
.1.3.6.1.4.1.18.3.5.9.7.8
wfSmdsSwCurUsageEntryThe usage data for the current usage period indexed by destination,source address.
WfSmdsSwCurUsageEntry
.1.3.6.1.4.1.18.3.5.9.7.8.1
wfSmdsSwCurUsageDeleteIndication to delete this current usage entry.rwobsolete
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.8.1.1
wfSmdsSwCurUsageSniThe SNI number of the interface generating the usage informationro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.8.1.2
wfSmdsSwCurUsageDestAddrThe destination address of a SMDS group or individual E.164 address.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.8.1.3
wfSmdsSwCurUsageSrcAddrThe source address of a SMDS individual E.164 address.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.8.1.4
wfSmdsSwCurUsageGrpIndAddrWhen the destination address of an L3_PDU is a group address, this attribute is set to one of the E.164 individual addresses that is in the group address and on the destination SNI.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.8.1.5
wfSmdsSwCurUsageNumL3PduThis number represents the number of billable L3_PDUs counted by the circuit during the most recent collection interval.ro
Counter
.1.3.6.1.4.1.18.3.5.9.7.8.1.6
wfSmdsSwCurUsageNumOctetThis number represents the number of billable octets counted by the circuit during the most recent collection interval.ro
Counter
.1.3.6.1.4.1.18.3.5.9.7.8.1.7
wfSmdsSwCurUsageToBeDeletedIndication to billing to delete this current usage entry.ro
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.8.1.8
wfSmdsSwUsage
OBJECT IDENTIFIER
.1.3.6.1.4.1.18.3.5.9.7.9
wfSmdsSwUsageEnableEnable/Disable SMDS_SW billing.rw
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.9.1
wfSmdsSwUsageVolumeIndicates the file system volume number to which the billing usage data files will be written. The volume number corresponds to the slot number on which the volume resides. Note: Value 0 has the special meaning that no 'Store' and 'Flush' operations will take place. This translates to no Billing data will be written to the local file system. 'Update' operations will still be performed on each local slot. Full Billing statistics will still be available in the wfSmdsSwUsageTable MIB.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.2
wfSmdsSwUsageVolumeBackupIndicates the backup volume if wfSmdsSwUsageVolume becomes inoperative. Note: This feature is not implemented in this release.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.3
wfSmdsSwUsageDirectoryThe name of the directory where the billing usage data files are stored.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18.3.5.9.7.9.4
wfSmdsSwUsageFilePrefixThe base name of billing usage data files.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18.3.5.9.7.9.5
wfSmdsSwUsageTimerIntervalThis number determines the timer interval (number of seconds) unit for the Billing process to perform its various timer driven tasks. i.e. updating billing usage data, writing billing usage data to file system and file system management activities.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.6
wfSmdsSwUsageUpdateIntervalThis number specifies the interval (number of minutes) for the Billing process to collect and update billing usage data in the wfSmdsSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfSmdsSwUsageTimerInterval.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.7
wfSmdsSwUsageStoreIntervalThis number specifies the interval (number of minutes) for the Billing process to write billing usage data on to the file system from the wfSmdsSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfSmdsSwUsageTimerInterval.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.8
wfSmdsSwUsageFlushIntervalThis number specifies the interval (number of minutes) for the Billing process to write billing usage data on to the file system from the wfSmdsSwUsage MIB followed by zeroing the wfSmdsSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfSmdsSwUsageTimerInterval.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.9
wfSmdsSwUsageCleanupIntervalThis is the interval (number of minutes) for the Billing process to check and delete old billing usage data files. Note: When converted to seconds, this must be a multilple of wfSmdsSwUsageTimerInterval.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.10
wfSmdsSwUsageLocalTimeZoneIndicates local time zone of the switchro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.11
wfSmdsSwUsageUpdateTimeStampTime stamp of last wfSmdsSwUsageUpdateInterval timer expiration or the starting time of the current wfSmdsSwUsageUpdateInterval. This value is number of seconds since midnight Jan 1, 1976 (GMT).ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.18.3.5.9.7.9.12
wfSmdsSwUsageStoreTimeStampTime stamp of last wfSmdsSwUsageStoreInterval timer expiration or the starting time of the current wfSmdsSwUsageStoreInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT).ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.18.3.5.9.7.9.13
wfSmdsSwUsageFlushTimeStampTime stamp of last wfSmdsSwUsageFlushInterval timer expiration or the starting time of the current wfSmdsSwUsageFlushInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT).ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.18.3.5.9.7.9.14
wfSmdsSwUsageCleanupTimeStampTime stamp of last wfSmdsSwUsageCleanupInterval timer expiration or the starting time of the current wfSmdsSwUsageCleanupInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT).ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.18.3.5.9.7.9.15
wfSmdsSwUsageUpdateDataSetting this attribute to a non-zero value will cause an immediate updating of the billing usage data. Once activated, this attribute should be reset to zero to allow subsequent activations.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.16
wfSmdsSwUsageStoreDataSetting this attribute to a non-zero value will cause an immediate updating and writing of the billing usage data. Once activated, this attribute should be reset to zero to allow subsequent activations.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.17
wfSmdsSwUsageFlushDataSetting this attribute to a non-zero value will cause an immediate updating and writing of the billing usage data and followed by zeroing the wfSmdsSwBillingUsage MIB. Once activated, this attribute should be reset to zero to allow subsequent activations.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.18
wfSmdsSwUsageFileCleanupSetting this attribute to a non-zero value will cause an immediate checking and deleting old billing usage data files. Once activated, this attribute should be reset to zero to allow subsequent activations.rw
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.19
wfSmdsSwUsageStatecurrent state of SMDS_SW billing.ro
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.9.20
wfSmdsSwUsageCurVolumecurrent file system volume number used. This number is the same as wfSmdsSwUsageVolume except when the user sets wfSmdsSwUsageVolume to an invalid number.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.21
wfSmdsSwUsageCurVolumeBackupcurent backup file system volume number used. This number is the same as wfSmdsSwUsageVolumeBackUp except when the user sets wfSmdsSwUsageVolume to an invalid number. Note: This feature is not implemented in this release.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.22
wfSmdsSwUsageCurDirectorycurrent directory name used. This number is the same as wfSmdsSwUsageDirectory except when the user sets wfSmdsSwUsageDirectory to an invalid name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18.3.5.9.7.9.23
wfSmdsSwUsageCurFilePrefixcurrent base file name used. This number is the same as wfSmdsSwUsageFilePrefix except when the user sets wfSmdsSwUsageFilePrefix to an invalid name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18.3.5.9.7.9.24
wfSmdsSwUsageCurTimerIntervalcurrent timer interval number used. This number is the same as wfSmdsSwUsageTimerInterval except when the user sets wfSmdsSwUsageTimerInterval to an invalid value.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.25
wfSmdsSwUsageCurUpdateIntervalcurrent update interval number used. This number is the same as wfSmdsSwUsageUpdateInterval except when the user sets wfSmdsSwUsageUpdateInterval to an invalid value.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.26
wfSmdsSwUsageCurStoreIntervalcurrent store timer interval number used. This number is the same as wfSmdsSwUsageStoreInterval except when the user sets wfSmdsSwUsageStoreInterval to an invalid value.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.27
wfSmdsSwUsageCurFlushIntervalcurrent flush timer interval number used. This number is the same as wfSmdsSwUsageFlushInterval except when the user sets wfSmdsSwUsageFlushInterval to an invalid value.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.28
wfSmdsSwUsageCurCleanupIntervalcurrent file cleanup timer interval number used. This number is the same as wfSmdsSwUsageCleanupInterval except when the user sets wfSmdsSwUsageCleanupInterval to an invalid value.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.29
wfSmdsSwUsageDebugEnable/Disable printing of debug edl (trap) messages. NOTE: Do not enable this attribute in operational enviornment as it will likely flood the logging facility. This attribute is reserved for specialized debugging in a controlled lab enviornment.rw
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.9.30
wfSmdsSwUsageCurDebugcurrent debug value used. This value is the same as wfSmdsSwUsageDebug except when the user sets wfSmdsSwUsageDeubg to an invalid value.ro
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.9.31
wfSmdsSwUsageSwitchIdswitch id used in the billing usage data file.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.32
wfSmdsSwUsageNumEntriesnumber of entries in wfSmdsSwUsageTablero
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.9.33
wfSmdsSwUsageTableThe Billing Usage Table.
SEQUENCE OF WfSmdsSwUsageEntry
.1.3.6.1.4.1.18.3.5.9.7.10
wfSmdsSwUsageEntryThe parameters for Billing Usage.
WfSmdsSwUsageEntry
.1.3.6.1.4.1.18.3.5.9.7.10.1
wfSmdsSwUsageDeleteIndicates status of this entry. SMDS_SW_USAGE_CREATED is the normal case. SMDS_SW_USAGE_DELETED means this billing instance will be deleted at the end of the next wfSmdsSwUsageFlush period after this billing record is written out to the file system.ro
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.10.1.1
wfSmdsSwUsageSniThe circuit number of the interface generating the usage informationro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.2
wfSmdsSwUsageDestAddrInstance identifier; the destination address of an L3_PDU. The SMDS Switch collects usage data based on the destination/source address pair.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.10.1.3
wfSmdsSwUsageSrcAddrInstance identifier; the source address of an L3_PDU. The SMDS Switch collects usage data based on the destination/source address pair.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.10.1.4
wfSmdsSwUsageStartTimeStampHighTime stamp of the starting time (the high 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT).ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.5
wfSmdsSwUsageStartTimeStampLowTime stamp of the starting time (the low 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT).ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.6
wfSmdsSwUsageEndTimeStampHighTime stamp of the ending time (the high 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT).ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.7
wfSmdsSwUsageEndTimeStampLowTime stamp of the ending time (the low 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT).ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.8
wfSmdsSwUsageSentL3PduHighNumber (the high 32 bits) of L3_PDUs sent to the CPE between wfSmdsSwUsageStartTimeStamp and wfSmdsSwUsageEndTimeStamp.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.9
wfSmdsSwUsageSentL3PduLowNumber (the low 32 bits) of L3_PDUs sent to the CPE between wfSmdsSwUsageStartTimeStamp and wfSmdsSwUsageEndTimeStamp.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.10
wfSmdsSwUsageSentOctetHighNumber (the high 32 bits) of octets sent to the CPE between wfSmdsSwUsageStartTimeStamp and wfSmdsSwUsageEndTimeStamp.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.11
wfSmdsSwUsageSentOctetLowNumber (the low 32 bits) of octets sent to the CPE between wfSmdsSwUsageStartTimeStamp and wfSmdsSwUsageEndTimeStamp.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.12
wfSmdsSwUsageLastL3PduHighThe (high 32 bits) value of wfSmdsSwCurUsageNumL3Pdu value at wfSmdsSwUsageEndTimeStamp. Note: Since wfSmdsSwCurUsageNumL3Pdu is a 32-bit COUNTER, this is really a counter keeping track of number of times wfSmdsSwCurUsageNumL3Pdu has wrapped around.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.13
wfSmdsSwUsageLastL3PduLowThe (low 32 bits) value of wfSmdsSwCurUsageNumL3Pdu value at wfSmdsSwUsageEndTimeStamp.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.14
wfSmdsSwUsageLastOctetHighThe (high 32 bits) value of wfSmdsSwCurUsageNumOctets value at wfSmdsSwUsageEndTimeStamp. Note: Since wfSmdsSwCurUsageNumOctets is a 32-bit COUNTER, this is really a counter keeping track of number of times wfSmdsSwCurUsageNumOctets has wrapped around.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.15
wfSmdsSwUsageLastOctetLowThe (low 32 bits) value of wfSmdsSwCurUsageNumOctets value at wfSmdsSwUsageEndTimeStamp.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.10.1.16
wfSmdsSwUsageGrpIndAddrWhen the destination address of an L3_PDU is a group address, this attribute is set to one of the E.164 individual addresses that is in the group address and on the destination SNI.ro
OCTET STRING
.1.3.6.1.4.1.18.3.5.9.7.10.1.17
wfSmdsSwSsiSniTableThe Parameters for the SSI/SNI Object. This object associates SNI's with SSI's for Bellcore TR-TSV-001239 compliance.
SEQUENCE OF WfSmdsSwSsiSniEntry
.1.3.6.1.4.1.18.3.5.9.7.11
wfSmdsSwSsiSniEntryThe parameters for a particular SSI/SNI.
WfSmdsSwSsiSniEntry
.1.3.6.1.4.1.18.3.5.9.7.11.1
wfSmdsSwSsiSniDeleteIndication to delete this SSI/SNI entry.rw
Enumeration
.1.3.6.1.4.1.18.3.5.9.7.11.1.1
wfSmdsSwSsiSniSSIAn SSI.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.11.1.2
wfSmdsSwSsiSniSNIAn SNI.ro
INTEGER
.1.3.6.1.4.1.18.3.5.9.7.11.1.3
wfSmdsSwSubEntryPer Wellfleet circuit SMDS Switch configuration parameters and counters. This table contains Subscriber-Network Interface (SNI) parameters and state variables, one entry per SIP port.
WfSmdsSwSubEntry
.wfSmdsSwSubTable.1
wfSmdsSwSubDeletecreate/delete parameter, dflt = createdrw
Enumeration
.wfSmdsSwSubTable.1.1
wfSmdsSwSubDisableenable/disable parameter, dflt = enabledrw
Enumeration
.wfSmdsSwSubTable.1.2
wfSmdsSwSubStateSMDS Switch state variable, Up, Down Init, Not Presentro
Enumeration
.wfSmdsSwSubTable.1.3
wfSmdsSwSubCctcct number for this instancero
INTEGER
.wfSmdsSwSubTable.1.4
wfSmdsSwSubDisableHrtbtPolldetermine use of DXI heartbeat pollrw
Enumeration
.wfSmdsSwSubTable.1.5
wfSmdsSwSubHrtbtPollAddrdetermine if heartbeat poll messages are sent as as CPE or network (CSU/DSU) messages.rw
Enumeration
.wfSmdsSwSubTable.1.6
wfSmdsSwSubHrtbtPollIntervalheartbeat polling messages get sent every this many seconds - we don't want the polling interval to be less than or equal to the no-acknowledgment timer.rw
INTEGER
.wfSmdsSwSubTable.1.7
wfSmdsSwSubHrtbtPollDownCountif this many consecutive heartbeat polling messages go unacknowledged, log an event declaring the line downrw
INTEGER
.wfSmdsSwSubTable.1.8
wfSmdsSwSubDisableNetMgmtdetermine use of LMI network managementrw
Enumeration
.wfSmdsSwSubTable.1.9
wfSmdsSwSubInterfaceTypedefines whether this interface is a SNI or SSI.rw
Enumeration
.wfSmdsSwSubTable.1.10
wfSmdsSwSubInterfaceIndexThe index number for the SSI/SNI. Each SNI in the network has a unique id. The value of this object identifies the SIP port interface for which this entry contains management information.rw
INTEGER
.wfSmdsSwSubTable.1.11
wfSmdsSwSubDisableL3PduChecksEnable/Disable L3_PDU verification. Default is disabled.rw
Enumeration
.wfSmdsSwSubTable.1.12
wfSmdsSwSubDisableUsageGenerationenable/disable usage data generation. Default is disabled.rw
Enumeration
.wfSmdsSwSubTable.1.13
wfSmdsSwSubDisableMIRenable/disable MIR enforcement, default is disabled.rw
Enumeration
.wfSmdsSwSubTable.1.14
wfSmdsSwSubUnassignedSAsThe total number of SIP Level 3 PDUs discarded by the SMDS Switch because the Source Address was not assigned to the SNI.ro
Counter
.wfSmdsSwSubTable.1.15
wfSmdsSwSubSAScreenViolationsThe number of SIP L3_PDUs that violated the address screen based on source address screening for an SNI.ro
Counter
.wfSmdsSwSubTable.1.16
wfSmdsSwSubDAScreenViolationsThe total number of SIP Level 3 PDUs that violated the Destination Address Screening using either an Individual Address Screen or a Group Address Screen for the SNI.ro
Counter
.wfSmdsSwSubTable.1.17
wfSmdsSwSubNumPDUExceededMIRThe total number of SIP L3_PDUs that exceeded the MIR on this interface.ro
Counter
.wfSmdsSwSubTable.1.18
wfSmdsSwSubSipL3ReceivedIAsThe total number of individually addressed SIP Level 3 PDUs received by the SMDS Switch from the CPE. The total includes only unerrored L3PDUs.ro
Counter
.wfSmdsSwSubTable.1.19
wfSmdsSwSubSipL3ReceivedGAsThe total number of group addressed SIP Level 3 PDUs received by the SMDS Switch from the CPE. The total includes only unerrored L3PDUs.ro
Counter
.wfSmdsSwSubTable.1.20
wfSmdsSwSubSipL3UnrecIAsThe number of SIP Level 3 PDUs received by the SMDS Switch from the CPE that have an unknown, valid, individual SMDS Destination Address.ro
Counter
.wfSmdsSwSubTable.1.21
wfSmdsSwSubSipL3UnrecGAsThe number of SIP Level 3 PDUs received by the SMDS Switch from the CPE that have an unknown, valid, group SMDS Destination Address.ro
Counter
.wfSmdsSwSubTable.1.22
wfSmdsSwSubSipL3SentIAsThe number of individually addressed SIP Level 3 PDUs that have been sent by this SMDS Switch to the CPE.ro
Counter
.wfSmdsSwSubTable.1.23
wfSmdsSwSubSipL3SentGAsThe number of group addressed SIP L3PDUs that have been sent by this SMDS Switch to the CPE.ro
Counter
.wfSmdsSwSubTable.1.24
wfSmdsSwSubSipL3ErrorsThe total number of SIP Level 3 PDUs received by the SMDS Switch from the CPE that were discovered to have protocol errors.ro
Counter
.wfSmdsSwSubTable.1.25
wfSmdsSwSubSipL3InvAddrTypesThe total number of SIP Level 3 PDUs received by the SMDS Switch from the CPE that had a value in the Source or Destination Address type subfield other than group or individual. Or if the Source Address type subfield value indicates a group address.ro
Counter
.wfSmdsSwSubTable.1.26
wfSmdsSwSubSipL3VersionSupportA value which indicates the version(s) of SIP that this SNI supports. The value is a sum. This sum initially takes the value zero. For each version, V, that this interface supports, 2 raised to (V - 1) is added to the sum. For example, a port supporting versions 1 and 2 would have a value of (2^(1-1)+2^(2-1))=3. The SipL3VersionSupport is effectively a bit mask with Version 1 equal to the least significant bit (LSB).ro
Enumeration
.wfSmdsSwSubTable.1.27
wfSmdsSwSubSAScrnViolationOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded as a result of a Source Address violation.ro
OCTET STRING
.wfSmdsSwSubTable.1.28
wfSmdsSwSubDAScrnViolationOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded as a result of a Destination Address violation.ro
OCTET STRING
.wfSmdsSwSubTable.1.29
wfSmdsSwSubUnassignedSAOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded as a result of a unassigned Source Address.ro
OCTET STRING
.wfSmdsSwSubTable.1.30
wfSmdsSwSubSAErrorOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of a Source Address Field Format error.ro
OCTET STRING
.wfSmdsSwSubTable.1.31
wfSmdsSwSubDAErrorOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of a Destination Address Field Format error.ro
OCTET STRING
.wfSmdsSwSubTable.1.32
wfSmdsSwSubInvalidBASizeOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an invalid BASize field value.ro
OCTET STRING
.wfSmdsSwSubTable.1.33
wfSmdsSwSubInvalidHELenOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an invalid Header Extension Length Field value.ro
OCTET STRING
.wfSmdsSwSubTable.1.34
wfSmdsSwSubInvalidHEVerOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an invalid Header Extension Version element.ro
OCTET STRING
.wfSmdsSwSubTable.1.35
wfSmdsSwSubInvalidHECarOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an invalid Header Extension Carrier element.ro
OCTET STRING
.wfSmdsSwSubTable.1.36
wfSmdsSwSubInvalidHEPadOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an invalid Header Extension Pad element.ro
OCTET STRING
.wfSmdsSwSubTable.1.37
wfSmdsSwSubBEtagOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of a Beginning-End Tag mismatch.ro
OCTET STRING
.wfSmdsSwSubTable.1.38
wfSmdsSwSubBAsizeNELenOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because the BAsize and Length fields are not equal.ro
OCTET STRING
.wfSmdsSwSubTable.1.39
wfSmdsSwSubIncorrectLenOccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an incorrect length.ro
OCTET STRING
.wfSmdsSwSubTable.1.40
wfSmdsSwSubExceededMIROccurA string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because it exceeded the MIR.ro
OCTET STRING
.wfSmdsSwSubTable.1.41
wfSmdsSwSubInBandMgmtDisableIn-Band Management enable/disable parameter. This attribute indicates whether the local WSNI (only) is enabled to run IP in Host mode, for in-band management purposes, in additional to being a switch interface. The default is disabledrw
Enumeration
.wfSmdsSwSubTable.1.42
wfSmdsSwSubInBandMgmtLocalAddrSpecial SMDS E.164 Individual address that identifies this local circuit. This attribute is only used when the wfSmdsSwSubInBandMgmtDisable attribute is set to ENABLEDrw
OCTET STRING
.wfSmdsSwSubTable.1.43
wfSmdsSwSubInBandMgmtReceivedPDUsThe total number of individually addressed In-Band Management PDUs received by the SMDS Switch from the CPE. The total includes only unerrored PDUs.ro
Counter
.wfSmdsSwSubTable.1.44
wfSmdsSwSubInBandMgmtSentPDUsThe number of individually addressed In-Band Management PDUs that have been sent by this SMDS Switch to the CPE.ro
Counter
.wfSmdsSwSubTable.1.45
wfSmdsSwSubInBandMgmtMaxLenErrorsThe number of In-Band Management PDUs that have exceeded the MTU size configured for the linero
Counter
.wfSmdsSwSubTable.1.46
wfSmdsSwSubInBandMgmtEncapsErrorsThe number of In-Band Management PDUs that have invalid encapsulation schemesro
Counter
.wfSmdsSwSubTable.1.47
wfSmdsSwSubGAPartialResolveThe number of times group addressed L3_PDU's could not be resolved due to congestion.ro
Counter
.wfSmdsSwSubTable.1.48
wfSmdsSwSubDANotOnSniThe number of times a L3_PDU was discarded at the egress because the destination address was not assigned to the SNI.ro
Counter
.wfSmdsSwSubTable.1.49
Wellfleet-SWSMDS-MIB - SNMP MIB Reference | MIBs Explorer