Home/Catalog/Wellfleet-DSUCSU-MIB

Wellfleet-DSUCSU-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

25
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

25 total
Object Name
wfDsuCsuIfTrapIndicates a change in the status of the line. The value returned in the trap will indicate the current state as defined in wfDsuCsuServiceStatus.
TRAP-TYPE
.1.3.6.1.4.1.18.3.4.30.0.1
RFC1155-SMIDSU CSU line record.
SEQUENCE OF WfDsuCsuIfEntry
.1.3.6.1.4.1.18.3.4.30.1
wfDsuCsuIfEntryAn entry in the DSU CSU IF table
WfDsuCsuIfEntry
.wfDsuCsuIfTable.1
wfDsuCsuIfDeleteCreate/Delete parameterrw
Enumeration
.wfDsuCsuIfTable.1.1
wfDsuCsuIfSlotInstance ID Slot, filled in by driverro
INTEGER
.wfDsuCsuIfTable.1.2
wfDsuCsuIfConnectorInstance ID Connector, filled in by the driver.ro
INTEGER
.wfDsuCsuIfTable.1.3
wfDsuCsuSoftRevDisplays the Software Revision of the DSU CSU card.ro
DisplayString
.wfDsuCsuIfTable.1.4
wfDsuCsuHardRevDisplays the Hardware Revision of the DSU CSU card.ro
DisplayString
.wfDsuCsuIfTable.1.5
wfDsuCsuOpModeIdentifies the type of telco service that the DSU CSU is connected to. Opmode should be set to dds1-56kbps (1) when connected to a DDS1 56 Kbps line. Opmode should be set to cc-64kbps (2) when connected to a Clear Channel 64Kbps line.rw
Enumeration
.wfDsuCsuIfTable.1.6
wfDsuCsuTxClkSelectDefault timing, or clock, source for transmiting data to the network. There must be only one source on a DDS line. Timing should always be slave (1) when connected to a network. Timing should be set to master (2) on either end of a private-wire configuration, with the other end being set to slave (1).rw
Enumeration
.wfDsuCsuIfTable.1.7
wfDsuCsuUnitResetEnables the operator to remotely reset the unit. Using this command will cause the unit to terminate all its connections and drop data.rw
Enumeration
.wfDsuCsuIfTable.1.8
wfDsuCsu64KTxMonitorThis signal is used in 64K Clear Channel mode to suppress customer data in the event that the data duplicates a network control code. A setting of enabled(1) suppresses customer data. A setting of disabled(2) allows all customer data through, which could potentially put the other end into a loop if the data duplicates a network control code.rw
Enumeration
.wfDsuCsuIfTable.1.9
wfDsuCsuOpStateIndicates the current operating state of the DSU CSU card.ro
Enumeration
.wfDsuCsuIfTable.1.10
wfDsuCsuServiceStatusThe Current status of the physical interface. Your network carrier can send Out-of-Service or Maintenance Mode codes.ro
Enumeration
.wfDsuCsuIfTable.1.11
wfDsuCsuV54LpbkEnables the operator to control, and examine the state of, V.54 loopbacks within the DSU CSU.rw
Enumeration
.wfDsuCsuIfTable.1.12
wfDsuCsuV54TimerDuration in seconds that a test specified in wfDsuCsuTestLpbk is to execute.rw
INTEGER
.wfDsuCsuIfTable.1.13
wfDsuCsuV54ErrorsIndicates the number of errors reported during the last loopback test. This count will only be updated for loopbacks with test pattern.ro
Counter
.wfDsuCsuIfTable.1.14
wfDsuCsuCqmsLaWindowIndicates the number of minutes within the window in which the availability of the line (network) is to be calculated. The availability of the line is an indication of the percentage of time the line has been in service. It is calculated as follows: (((wfDsuCsuCqmsLaWindow*60) - (wfDsuCsuCqmsLaErrCnt*wfDsuCsuCqmsLaPollRate))/ wfDsuCsuCqmsLaWindow*60)rw
INTEGER
.wfDsuCsuIfTable.1.15
wfDsuCsuCqmsLaErrorsIndicates the total number of seconds that the line was not in service in the last window of size wfDsuCsuCqmsLaWindow.ro
Counter
.wfDsuCsuIfTable.1.16
wfDsuCsuCqmsLaPollRateIndicates the number of seconds between polls for line status from the DsuCsu. A value of 1 forces polling every second. A value of 60 forces polling every minute.rw
INTEGER
.wfDsuCsuIfTable.1.17
wfDsuCsuCqmsResetResets the CQMS counters to their default values. For Line Availability, wfDsuCsuCqmsLaErrCnt is reset.rw
Enumeration
.wfDsuCsuIfTable.1.18
wfDsuCsuOOSErrorsThe number of seconds in which Out of Service control codes were received from the Telco. The counter is incremented whenever a sample within a second indicated the unit received an out of service control code.ro
Counter
.wfDsuCsuIfTable.1.19
wfDsuCsuFrameErrorsThe number of seconds in which the unit was out of frame with the Telco. This is only applicable in 64K mode. The counter is incremented whenever a sample within a second indicated the unit was out of frame.ro
Counter
.wfDsuCsuIfTable.1.20
wfDsuCsuLOLErrorsThe number of seconds in which the unit has detected that no signal is present on the line, and/or no line is present.ro
Counter
.wfDsuCsuIfTable.1.21
wfDsuCsuInitStateIndictes the state of the DSU/CSU initialization sequence. The state will indicate if the DSU/CSU has been initialized and is in the *monitor* state polling the card for line condition, or in the *loopback state running a user-initiated loopbackro
Enumeration
.wfDsuCsuIfTable.1.22