Home/Catalog/Wellfleet-DS3-MIB

Wellfleet-DS3-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

66
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

66 total
Object Name
RFC1155-SMIThe DS3 Configuration table
SEQUENCE OF WfDs3ConfigEntry
.1.3.6.1.4.1.18.3.4.13.1
wfDs3ConfigEntryper circuit DS3 configuration objects; wfDs3LineIndex corresponds to Wellfleet circuit number
WfDs3ConfigEntry
.1.3.6.1.4.1.18.3.4.13.1.1
wfDs3LineIndexthis corresponds to the Wellfleet circuit numberro
INTEGER
.1.3.6.1.4.1.18.3.4.13.1.1.1
wfDs3TimeElapsed1..900 seconds within the current 15-minute intervalro
INTEGER
.1.3.6.1.4.1.18.3.4.13.1.1.2
wfDs3ValidIntervals0..96 previous intervals that valid data were collected. This is 96 unless the CSU device was brought on line within the last 24 hours.ro
INTEGER
.1.3.6.1.4.1.18.3.4.13.1.1.3
wfDs3LineTypethe variety of DS3 implementing this circuitro
Enumeration
.1.3.6.1.4.1.18.3.4.13.1.1.4
wfDs3ZeroCodingthe variety of Zero Code Suppression used on the linkro
Enumeration
.1.3.6.1.4.1.18.3.4.13.1.1.5
wfDs3SendCodethe type of code being sent across the DS3 circuit by the CSUro
Enumeration
.1.3.6.1.4.1.18.3.4.13.1.1.6
wfDs3CircuitIdentifierthe transmission vendor's circuit identifierro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18.3.4.13.1.1.7
wfDs3LoopbackConfigthe loopback state of the CSUro
Enumeration
.1.3.6.1.4.1.18.3.4.13.1.1.8
wfDs3LineStatusthe state of the DS3 linero
Enumeration
.1.3.6.1.4.1.18.3.4.13.1.1.9
wfDs3CurrentThe DS3 Current table
SEQUENCE OF WfDs3CurrentEntry
.1.3.6.1.4.1.18.3.4.13.2
wfDs3CurrentEntryper circuit DS3 current objects - wfDs3CurrentIndex corresponds to Wellfleet circuit number
WfDs3CurrentEntry
.1.3.6.1.4.1.18.3.4.13.2.1
wfDs3CurrentIndexthis corresponds to the Wellfleet circuit numberro
INTEGER
.1.3.6.1.4.1.18.3.4.13.2.1.1
wfDs3CurrentESsthe count of errored seconds in the current intervalro
Counter
.1.3.6.1.4.1.18.3.4.13.2.1.2
wfDs3CurrentSESsthe count of severely errored seconds in the current intervalro
Counter
.1.3.6.1.4.1.18.3.4.13.2.1.3
wfDs3CurrentSEFsthe count of severely errored framing seconds in the current intervalro
Counter
.1.3.6.1.4.1.18.3.4.13.2.1.4
wfDs3CurrentUASsthe number of unavailable seconds in the current intervalro
Counter
.1.3.6.1.4.1.18.3.4.13.2.1.5
wfDs3CurrentBPVsthe count of bipolar violations in the current intervalro
Counter
.1.3.6.1.4.1.18.3.4.13.2.1.6
wfDs3CurrentCVsthe count of code violation error events in the current intervalro
Counter
.1.3.6.1.4.1.18.3.4.13.2.1.7
wfDs3IntervalThe DS3 Interval table
SEQUENCE OF WfDs3IntervalEntry
.1.3.6.1.4.1.18.3.4.13.3
wfDs3IntervalEntryper circuit DS3 interval objects - wfDs3IntervalIndex corresponds to Wellfleet circuit number, wfDs3IntervalNumber is the numbered previous 15-minute interval
WfDs3IntervalEntry
.1.3.6.1.4.1.18.3.4.13.3.1
wfDs3IntervalIndexthis corresponds to the Wellfleet circuit numberro
INTEGER
.1.3.6.1.4.1.18.3.4.13.3.1.1
wfDs3IntervalNumber1..96 where 1 is the most recent 15-minute interval and 96 is the leastro
INTEGER
.1.3.6.1.4.1.18.3.4.13.3.1.2
wfDs3IntervalESsthe count of errored seconds in the specified intervalro
Gauge
.1.3.6.1.4.1.18.3.4.13.3.1.3
wfDs3IntervalSESsthe count of severely errored seconds in the specified intervalro
Gauge
.1.3.6.1.4.1.18.3.4.13.3.1.4
wfDs3IntervalSEFsthe count of severely errored framing seconds in the specified intervalro
Gauge
.1.3.6.1.4.1.18.3.4.13.3.1.5
wfDs3IntervalUASsthe number of unavailable seconds in the specified intervalro
Gauge
.1.3.6.1.4.1.18.3.4.13.3.1.6
wfDs3IntervalBPVsthe count of bipolar violations in the specified intervalro
Gauge
.1.3.6.1.4.1.18.3.4.13.3.1.7
wfDs3IntervalCVsthe count of code violation error events in the specified intervalro
Gauge
.1.3.6.1.4.1.18.3.4.13.3.1.8
wfDs3TotalThe DS3 Total table
SEQUENCE OF WfDs3TotalEntry
.1.3.6.1.4.1.18.3.4.13.4
wfDs3TotalEntryper circuit DS3 total objects - wfDs3TotalIndex corresponds to Wellfleet circuit number
WfDs3TotalEntry
.1.3.6.1.4.1.18.3.4.13.4.1
wfDs3TotalIndexthis corresponds to the Wellfleet circuit numberro
INTEGER
.1.3.6.1.4.1.18.3.4.13.4.1.1
wfDs3TotalESstotal count of errored secondsro
Gauge
.1.3.6.1.4.1.18.3.4.13.4.1.2
wfDs3TotalSESstotal count of severely errored secondsro
Gauge
.1.3.6.1.4.1.18.3.4.13.4.1.3
wfDs3TotalSEFstotal count of severely errored framing secondsro
Gauge
.1.3.6.1.4.1.18.3.4.13.4.1.4
wfDs3TotalUASstotal number of unavailable secondsro
Gauge
.1.3.6.1.4.1.18.3.4.13.4.1.5
wfDs3TotalBPVstotal count of bipolar violationsro
Gauge
.1.3.6.1.4.1.18.3.4.13.4.1.6
wfDs3TotalCVstotal count of code violation error eventsro
Gauge
.1.3.6.1.4.1.18.3.4.13.4.1.7
wfDs3FeConfigThe DS3 Far End Configuration table
SEQUENCE OF WfDs3FeConfigEntry
.1.3.6.1.4.1.18.3.4.13.5
wfDs3FeConfigEntryper circuit DS3 far end config objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number
WfDs3FeConfigEntry
.1.3.6.1.4.1.18.3.4.13.5.1
wfDs3FeConfigIndexthis corresponds to the Wellfleet circuit numberro
INTEGER
.1.3.6.1.4.1.18.3.4.13.5.1.1
wfDs3FarEndEquipCodeequipment description code - C-bit parity onlyrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18.3.4.13.5.1.2
wfDs3FarEndLocationIDCodeequipment location code - C-bit parity onlyrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18.3.4.13.5.1.3
wfDs3FarEndFrameIDCodecode for the equipment location within a buildingrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18.3.4.13.5.1.4
wfDs3FarEndUnitCodecode for the equipment location within a bayrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18.3.4.13.5.1.5
wfDs3FarEndFacilityIDCodepath identification coderw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18.3.4.13.5.1.6
wfDs3FeCurrentThe DS3 Far End Current table
SEQUENCE OF WfDs3FeCurrentEntry
.1.3.6.1.4.1.18.3.4.13.6
wfDs3FeCurrentEntryper circuit DS3 far end current objects wfDs3FeCurrentIndex corresponds to Wellfleet circuit number
WfDs3FeCurrentEntry
.1.3.6.1.4.1.18.3.4.13.6.1
wfDs3FeCurrentIndexthis corresponds to the Wellfleet circuit numberro
INTEGER
.1.3.6.1.4.1.18.3.4.13.6.1.1
wfDs3FeCurrentESsthe count of errored seconds in the current intervalro
Counter
.1.3.6.1.4.1.18.3.4.13.6.1.2
wfDs3FeCurrentSESsthe count of severely errored seconds in the current intervalro
Counter
.1.3.6.1.4.1.18.3.4.13.6.1.3
wfDs3FeCurrentCVsthe count of code violation error events in the current intervalro
Counter
.1.3.6.1.4.1.18.3.4.13.6.1.4
wfDs3FeIntervalThe DS3 Far End Interval table
SEQUENCE OF WfDs3FeIntervalEntry
.1.3.6.1.4.1.18.3.4.13.7
wfDs3FeIntervalEntryper circuit DS3 far end interval objects - wfDs3FeIntervalIndex corresponds to Wellfleet circuit number, wfDs3FeIntervalNumber is the numbered previous 15-minute interval
WfDs3FeIntervalEntry
.1.3.6.1.4.1.18.3.4.13.7.1
wfDs3FeIntervalIndexthis corresponds to the Wellfleet circuit numberro
INTEGER
.1.3.6.1.4.1.18.3.4.13.7.1.1
wfDs3FeIntervalNumber1..96 where 1 is the most recent 15-minute interval and 96 is the leastro
INTEGER
.1.3.6.1.4.1.18.3.4.13.7.1.2
wfDs3FeIntervalESsthe count of errored seconds in the specified intervalro
Gauge
.1.3.6.1.4.1.18.3.4.13.7.1.3
wfDs3FeIntervalSESsthe count of severely errored seconds in the specified intervalro
Gauge
.1.3.6.1.4.1.18.3.4.13.7.1.4
wfDs3FeIntervalCVsthe count of code violation error events in the specified intervalro
Gauge
.1.3.6.1.4.1.18.3.4.13.7.1.5
wfDs3FeTotalThe DS3 Far End Total table
SEQUENCE OF WfDs3FeTotalEntry
.1.3.6.1.4.1.18.3.4.13.8
wfDs3FeTotalEntryper circuit far end DS3 total objects - wfDs3FeTotalIndex corresponds to Wellfleet circuit number
WfDs3FeTotalEntry
.1.3.6.1.4.1.18.3.4.13.8.1
wfDs3FeTotalIndexthis corresponds to the Wellfleet circuit numberro
INTEGER
.1.3.6.1.4.1.18.3.4.13.8.1.1
wfDs3FeTotalESstotal count of errored secondsro
Gauge
.1.3.6.1.4.1.18.3.4.13.8.1.2
wfDs3FeTotalSESstotal count of severely errored secondsro
Gauge
.1.3.6.1.4.1.18.3.4.13.8.1.3
wfDs3FeTotalCVstotal count of code violation error eventsro
Gauge
.1.3.6.1.4.1.18.3.4.13.8.1.4