Wellfleet-DS3-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
66
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
66 total| Object Name |
|---|
RFC1155-SMIThe DS3 Configuration table SEQUENCE OF WfDs3ConfigEntry .1.3.6.1.4.1.18.3.4.13.1 |
wfDs3ConfigEntryper circuit DS3 configuration objects; wfDs3LineIndex
corresponds to Wellfleet circuit number WfDs3ConfigEntry .1.3.6.1.4.1.18.3.4.13.1.1 |
wfDs3LineIndexthis corresponds to the Wellfleet circuit numberro INTEGER .1.3.6.1.4.1.18.3.4.13.1.1.1 |
wfDs3TimeElapsed1..900 seconds within the current 15-minute intervalro INTEGER .1.3.6.1.4.1.18.3.4.13.1.1.2 |
wfDs3ValidIntervals0..96 previous intervals that valid data
were collected. This is 96 unless the CSU
device was brought on line within the last 24
hours.ro INTEGER .1.3.6.1.4.1.18.3.4.13.1.1.3 |
wfDs3LineTypethe variety of DS3 implementing this circuitro Enumeration .1.3.6.1.4.1.18.3.4.13.1.1.4 |
wfDs3ZeroCodingthe variety of Zero Code Suppression used on the linkro Enumeration .1.3.6.1.4.1.18.3.4.13.1.1.5 |
wfDs3SendCodethe type of code being sent across the DS3 circuit by
the CSUro Enumeration .1.3.6.1.4.1.18.3.4.13.1.1.6 |
wfDs3CircuitIdentifierthe transmission vendor's circuit identifierro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.18.3.4.13.1.1.7 |
wfDs3LoopbackConfigthe loopback state of the CSUro Enumeration .1.3.6.1.4.1.18.3.4.13.1.1.8 |
wfDs3LineStatusthe state of the DS3 linero Enumeration .1.3.6.1.4.1.18.3.4.13.1.1.9 |
wfDs3CurrentThe DS3 Current table SEQUENCE OF WfDs3CurrentEntry .1.3.6.1.4.1.18.3.4.13.2 |
wfDs3CurrentEntryper circuit DS3 current objects - wfDs3CurrentIndex
corresponds to Wellfleet circuit number WfDs3CurrentEntry .1.3.6.1.4.1.18.3.4.13.2.1 |
wfDs3CurrentIndexthis corresponds to the Wellfleet circuit numberro INTEGER .1.3.6.1.4.1.18.3.4.13.2.1.1 |
wfDs3CurrentESsthe count of errored seconds in the current intervalro Counter .1.3.6.1.4.1.18.3.4.13.2.1.2 |
wfDs3CurrentSESsthe count of severely errored seconds in the
current intervalro Counter .1.3.6.1.4.1.18.3.4.13.2.1.3 |
wfDs3CurrentSEFsthe count of severely errored framing seconds in the current
intervalro Counter .1.3.6.1.4.1.18.3.4.13.2.1.4 |
wfDs3CurrentUASsthe number of unavailable seconds in the current intervalro Counter .1.3.6.1.4.1.18.3.4.13.2.1.5 |
wfDs3CurrentBPVsthe count of bipolar violations in the current intervalro Counter .1.3.6.1.4.1.18.3.4.13.2.1.6 |
wfDs3CurrentCVsthe count of code violation error events in the
current intervalro Counter .1.3.6.1.4.1.18.3.4.13.2.1.7 |
wfDs3IntervalThe DS3 Interval table SEQUENCE OF WfDs3IntervalEntry .1.3.6.1.4.1.18.3.4.13.3 |
wfDs3IntervalEntryper circuit DS3 interval objects - wfDs3IntervalIndex
corresponds to Wellfleet circuit number,
wfDs3IntervalNumber is the numbered previous
15-minute interval WfDs3IntervalEntry .1.3.6.1.4.1.18.3.4.13.3.1 |
wfDs3IntervalIndexthis corresponds to the Wellfleet circuit numberro INTEGER .1.3.6.1.4.1.18.3.4.13.3.1.1 |
wfDs3IntervalNumber1..96 where 1 is the most recent 15-minute interval and 96 is
the leastro INTEGER .1.3.6.1.4.1.18.3.4.13.3.1.2 |
wfDs3IntervalESsthe count of errored seconds in the specified intervalro Gauge .1.3.6.1.4.1.18.3.4.13.3.1.3 |
wfDs3IntervalSESsthe count of severely errored seconds in the specified
intervalro Gauge .1.3.6.1.4.1.18.3.4.13.3.1.4 |
wfDs3IntervalSEFsthe count of severely errored framing seconds in the specified
intervalro Gauge .1.3.6.1.4.1.18.3.4.13.3.1.5 |
wfDs3IntervalUASsthe number of unavailable seconds in the specified intervalro Gauge .1.3.6.1.4.1.18.3.4.13.3.1.6 |
wfDs3IntervalBPVsthe count of bipolar violations in the specified intervalro Gauge .1.3.6.1.4.1.18.3.4.13.3.1.7 |
wfDs3IntervalCVsthe count of code violation error events in the
specified intervalro Gauge .1.3.6.1.4.1.18.3.4.13.3.1.8 |
wfDs3TotalThe DS3 Total table SEQUENCE OF WfDs3TotalEntry .1.3.6.1.4.1.18.3.4.13.4 |
wfDs3TotalEntryper circuit DS3 total objects - wfDs3TotalIndex
corresponds to Wellfleet circuit number WfDs3TotalEntry .1.3.6.1.4.1.18.3.4.13.4.1 |
wfDs3TotalIndexthis corresponds to the Wellfleet circuit numberro INTEGER .1.3.6.1.4.1.18.3.4.13.4.1.1 |
wfDs3TotalESstotal count of errored secondsro Gauge .1.3.6.1.4.1.18.3.4.13.4.1.2 |
wfDs3TotalSESstotal count of severely errored secondsro Gauge .1.3.6.1.4.1.18.3.4.13.4.1.3 |
wfDs3TotalSEFstotal count of severely errored framing secondsro Gauge .1.3.6.1.4.1.18.3.4.13.4.1.4 |
wfDs3TotalUASstotal number of unavailable secondsro Gauge .1.3.6.1.4.1.18.3.4.13.4.1.5 |
wfDs3TotalBPVstotal count of bipolar violationsro Gauge .1.3.6.1.4.1.18.3.4.13.4.1.6 |
wfDs3TotalCVstotal count of code violation error eventsro Gauge .1.3.6.1.4.1.18.3.4.13.4.1.7 |
wfDs3FeConfigThe DS3 Far End Configuration table SEQUENCE OF WfDs3FeConfigEntry .1.3.6.1.4.1.18.3.4.13.5 |
wfDs3FeConfigEntryper circuit DS3 far end config objects -
wfDs3FeIntervalIndex corresponds to Wellfleet circuit
number WfDs3FeConfigEntry .1.3.6.1.4.1.18.3.4.13.5.1 |
wfDs3FeConfigIndexthis corresponds to the Wellfleet circuit numberro INTEGER .1.3.6.1.4.1.18.3.4.13.5.1.1 |
wfDs3FarEndEquipCodeequipment description code - C-bit parity onlyrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.18.3.4.13.5.1.2 |
wfDs3FarEndLocationIDCodeequipment location code - C-bit parity onlyrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.18.3.4.13.5.1.3 |
wfDs3FarEndFrameIDCodecode for the equipment location within a buildingrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.18.3.4.13.5.1.4 |
wfDs3FarEndUnitCodecode for the equipment location within a bayrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.18.3.4.13.5.1.5 |
wfDs3FarEndFacilityIDCodepath identification coderw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.18.3.4.13.5.1.6 |
wfDs3FeCurrentThe DS3 Far End Current table SEQUENCE OF WfDs3FeCurrentEntry .1.3.6.1.4.1.18.3.4.13.6 |
wfDs3FeCurrentEntryper circuit DS3 far end current objects
wfDs3FeCurrentIndex corresponds to Wellfleet circuit
number WfDs3FeCurrentEntry .1.3.6.1.4.1.18.3.4.13.6.1 |
wfDs3FeCurrentIndexthis corresponds to the Wellfleet circuit numberro INTEGER .1.3.6.1.4.1.18.3.4.13.6.1.1 |
wfDs3FeCurrentESsthe count of errored seconds in the current intervalro Counter .1.3.6.1.4.1.18.3.4.13.6.1.2 |
wfDs3FeCurrentSESsthe count of severely errored seconds in the
current intervalro Counter .1.3.6.1.4.1.18.3.4.13.6.1.3 |
wfDs3FeCurrentCVsthe count of code violation error events in the
current intervalro Counter .1.3.6.1.4.1.18.3.4.13.6.1.4 |
wfDs3FeIntervalThe DS3 Far End Interval table SEQUENCE OF WfDs3FeIntervalEntry .1.3.6.1.4.1.18.3.4.13.7 |
wfDs3FeIntervalEntryper circuit DS3 far end interval objects -
wfDs3FeIntervalIndex corresponds to Wellfleet circuit
number, wfDs3FeIntervalNumber is the numbered previous
15-minute interval WfDs3FeIntervalEntry .1.3.6.1.4.1.18.3.4.13.7.1 |
wfDs3FeIntervalIndexthis corresponds to the Wellfleet circuit numberro INTEGER .1.3.6.1.4.1.18.3.4.13.7.1.1 |
wfDs3FeIntervalNumber1..96 where 1 is the most recent 15-minute interval and 96 is
the leastro INTEGER .1.3.6.1.4.1.18.3.4.13.7.1.2 |
wfDs3FeIntervalESsthe count of errored seconds in the specified intervalro Gauge .1.3.6.1.4.1.18.3.4.13.7.1.3 |
wfDs3FeIntervalSESsthe count of severely errored seconds in the
specified intervalro Gauge .1.3.6.1.4.1.18.3.4.13.7.1.4 |
wfDs3FeIntervalCVsthe count of code violation error events in the
specified intervalro Gauge .1.3.6.1.4.1.18.3.4.13.7.1.5 |
wfDs3FeTotalThe DS3 Far End Total table SEQUENCE OF WfDs3FeTotalEntry .1.3.6.1.4.1.18.3.4.13.8 |
wfDs3FeTotalEntryper circuit far end DS3 total objects - wfDs3FeTotalIndex
corresponds to Wellfleet circuit number WfDs3FeTotalEntry .1.3.6.1.4.1.18.3.4.13.8.1 |
wfDs3FeTotalIndexthis corresponds to the Wellfleet circuit numberro INTEGER .1.3.6.1.4.1.18.3.4.13.8.1.1 |
wfDs3FeTotalESstotal count of errored secondsro Gauge .1.3.6.1.4.1.18.3.4.13.8.1.2 |
wfDs3FeTotalSESstotal count of severely errored secondsro Gauge .1.3.6.1.4.1.18.3.4.13.8.1.3 |
wfDs3FeTotalCVstotal count of code violation error eventsro Gauge .1.3.6.1.4.1.18.3.4.13.8.1.4 |