SIAE-ALARM-MIB
AI MIB Summary
The SIAE-ALARM-MIB module enables the monitoring of network element alarm state transitions and the retrieval of active alarm entries via SNMP for SIAE-managed infrastructure. It specifically tracks alarm severity, timestamp, and status changes to facilitate real-time fault detection and event logging.
Logger of the transitions of NE alarms and active alarm table.
Main OID:
smalarm.1.3.6.1.4.1.3373.1103.4
56
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
56 total| Object Name |
|---|
alarmTrap OBJECT IDENTIFIER .1.3.6.1.4.1.3373.1103.0 |
alarmLogFTPStatusTrapThis event is generated when the status of FTP transfer is changed. The data passed with the event are: 1) alarmIpSnmpAgentAddress 2) alarmLogFTPStatus 3) accessControlLoginIpAddress NOTIFICATION-TYPE .1.3.6.1.4.1.3373.1103.0.401 |
alarmTrapObjectThis event is generated for every changed alarm status. NOTIFICATION-TYPE .1.3.6.1.4.1.3373.1103.0.3373 |
smalarmLogger of the transitions of NE alarms and active alarm table. MODULE-IDENTITY .1.3.6.1.4.1.3373.1103.4 |
alarmMibVersionNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.ro INTEGER .1.3.6.1.4.1.3373.1103.4.1 |
siaeNotificationEntry OBJECT IDENTIFIER .1.3.6.1.4.1.3373.1103.4.2 |
alarmObjectIdOID of the status changed alarmro OBJECT IDENTIFIER .1.3.6.1.4.1.3373.1103.4.2.1 |
alarmObjectValINTEGER value of the status changed alarmro AlarmStatus .1.3.6.1.4.1.3373.1103.4.2.2 |
alarmTrapDescriptionOptional Description of the notificationro OCTET STRING .1.3.6.1.4.1.3373.1103.4.2.3 |
alarmTrapNumberSequential number of trap sent from NEro Unsigned32 .1.3.6.1.4.1.3373.1103.4.2.4 |
alarmIpSnmpAgentAddressReflects the value of equipIpSnmpAgentAddress.ro IpAddress .1.3.6.1.4.1.3373.1103.4.2.5 |
alarmLogTableTable with Alarm records of the logger. SEQUENCE OF AlarmLogRecord .1.3.6.1.4.1.3373.1103.4.3 |
alarmLogRecordAlarm record of the logger. AlarmLogRecord .1.3.6.1.4.1.3373.1103.4.3.1 |
alarmLogRecordIdThis object is used as Index of alarmLogTable.ro Integer32 .1.3.6.1.4.1.3373.1103.4.3.1.1 |
alarmLogObjectIdThe Object Identifier of the Managed Object with Alarms or Controls active (not cleared Alarm Status).ro OBJECT IDENTIFIER .1.3.6.1.4.1.3373.1103.4.3.1.2 |
alarmLogObjectValAlarm Status with associated severity.ro AlarmStatus .1.3.6.1.4.1.3373.1103.4.3.1.3 |
alarmLogObjectSevSeverity associated to the Alarmro AlarmSeverityCode .1.3.6.1.4.1.3373.1103.4.3.1.4 |
alarmLogDescriptionASCII string used to describe the event.ro DisplayString .1.3.6.1.4.1.3373.1103.4.3.1.5 |
alarmLogEventTimeThe time (in secs) when the event was registered in the Log since 01-Gen-1970.ro Unsigned32 .1.3.6.1.4.1.3373.1103.4.3.1.6 |
alarmLogActionRequestThis object is used to delete or to read the LOG using Ftp (file transfer).rw Enumeration .1.3.6.1.4.1.3373.1103.4.4 |
alarmLogFTPfilePath and file name used when the log is transferred using Ftp (action = read).rw DisplayString .1.3.6.1.4.1.3373.1103.4.5 |
alarmLogAlarmSeverityEnableThis object enables the event record write in the log according to the severity: Bit0 = Status Bit1 = Warning Bit2 = Minor Bit3 = Major Bit4 = Critical.rw Integer32 .1.3.6.1.4.1.3373.1103.4.6 |
alarmLogStartHourEnableThis object defines whit AlarmLogEndHourEnable the period during a day when the alarm records must be written in the log.rw INTEGER .1.3.6.1.4.1.3373.1103.4.7 |
alarmLogEndHourEnableThis object defines whit AlarmLogStartHourEnable the period during a day when the alarm records must be written in the log.rw INTEGER .1.3.6.1.4.1.3373.1103.4.8 |
alarmLogStartTimeFilterThe events with EventTime greater than this object are read/delete from the log. Null value means no filter.rw Unsigned32 .1.3.6.1.4.1.3373.1103.4.9 |
alarmLogEndTimeFilterThe events with EventTime less than this object are read/delete from the log. Null value means no filter.rw Unsigned32 .1.3.6.1.4.1.3373.1103.4.10 |
alarmLogManagedObjectFilterThe Object Identifier of the Managed Object that has to be read/delete from the log. Null value means no filter.rw OBJECT IDENTIFIER .1.3.6.1.4.1.3373.1103.4.11 |
alarmLogAlarmSeverityFilterThis object defines the alarm severity of the records that must be read/delete from the log. Bit0 = Status Bit1 = Warning Bit2 = Minor Bit3 = Major Bit4 = Critical.rw Integer32 .1.3.6.1.4.1.3373.1103.4.12 |
alarmLogFTPStatusStatus of alarm logger Ftp transfer operation.ro Enumeration .1.3.6.1.4.1.3373.1103.4.14 |
alarmLogFTPStatusTrapNotificationEnables/disables the trap generation on FTP tranfer operation.rw Enumeration .1.3.6.1.4.1.3373.1103.4.15 |
alarmLogLastEventTimeIt is the Event time of the last alarm inserted into the alarm log.ro Unsigned32 .1.3.6.1.4.1.3373.1103.4.16 |
alarmActiveTableTable with one record for each Alarms&Controls that is active in the NE. SEQUENCE OF AlarmActiveRecord .1.3.6.1.4.1.3373.1103.4.17 |
alarmActiveRecordAlarms&Controls record. AlarmActiveRecord .1.3.6.1.4.1.3373.1103.4.17.1 |
alarmActiveObjectIdThe Object Identifier of the Managed Object with Alarms or Controls active (not cleared Alarm Status).ro OBJECT IDENTIFIER .1.3.6.1.4.1.3373.1103.4.17.1.1 |
alarmActiveObjectValAlarm Status with associated severity.ro AlarmStatus .1.3.6.1.4.1.3373.1103.4.17.1.2 |
alarmActiveDescriptionASCII string used to describe the event.ro DisplayString .1.3.6.1.4.1.3373.1103.4.17.1.3 |
alarmActiveEventTimeThe time when the Alarm became active. In seconds since 01/01/70.ro Unsigned32 .1.3.6.1.4.1.3373.1103.4.17.1.4 |
alarmActiveFloodingStatusIndicates the 'flooding' status.ro Enumeration .1.3.6.1.4.1.3373.1103.4.17.1.5 |
alarmSyntesysCriticalOR of all Critical Alarms.ro Enumeration .1.3.6.1.4.1.3373.1103.4.18 |
alarmSyntesysCriticalSeverityCodeDefines the severity associated to the alarmSyntesysCritical and enables/disables the trap generation on status change event.rw Enumeration .1.3.6.1.4.1.3373.1103.4.19 |
alarmSyntesysMajorOR of all Major Alarms.ro Enumeration .1.3.6.1.4.1.3373.1103.4.20 |
alarmSyntesysMajorSeverityCodeDefines the severity associated to alarmSyntesysMajor and enables/disables the trap generation on status change event.rw Enumeration .1.3.6.1.4.1.3373.1103.4.21 |
alarmSyntesysMinorOR of all Minor Alarms.ro Enumeration .1.3.6.1.4.1.3373.1103.4.22 |
alarmSyntesysMinorSeverityCodeDefines the severity associated to alarmSyntesysMinor and enables/disables the trap generation on status change event.rw Enumeration .1.3.6.1.4.1.3373.1103.4.23 |
alarmSyntesysWarningOR of all Warning Alarms.ro Enumeration .1.3.6.1.4.1.3373.1103.4.24 |
alarmSyntesysWarningSeverityCodeDefines the severity associated to alarmSyntesysStatus and enables/disables the trap generation on status change event.rw Enumeration .1.3.6.1.4.1.3373.1103.4.25 |
alarmSyntesysStatusOR of all Warning Alarms.ro Enumeration .1.3.6.1.4.1.3373.1103.4.26 |
alarmSyntesysStatusSeverityCodeDefines the severity associated to alarmSyntesysStatus and enables/disables the trap generation on status change event.rw Enumeration .1.3.6.1.4.1.3373.1103.4.27 |
alarmAntiFloodingEnables or disables the alarm anti-flooding (filtering) algorithm. According to such algorithm if the number of event notifications that an alarm receives within a specified time period, namely the observation period, exceeds a given high threshold value, the alarm enters a 'flooding' state. Once an alarm has entered such flooding state, its status is forced to active, according to its related severity, and no further event notifications are processed (neither trapped nor logged). An alarm exits the flooding state when the number of event notifications, received within a subsequent observation period, drops below a given low thresold value. On exiting the flooding state, the trap and log status of an alarm get aligned to the last notified event.rw Enumeration .1.3.6.1.4.1.3373.1103.4.28 |
alarmAntiFloodingWindowDefines the time duration in seconds of the observation period, during which the number of event notifications of any alarm is checked to determine the alarm flooding state.rw INTEGER .1.3.6.1.4.1.3373.1103.4.29 |
alarmAntiFloodingHighWaterDefines the threshold value of the number of event notifications, occurring during the observation period, beyond which an alarm enters the flooding state.rw INTEGER .1.3.6.1.4.1.3373.1103.4.30 |
alarmAntiFloodingLowWaterDefines the threshold value of the number of event notifications, occurring during the observation period, below which an alarm exits the flooding state. The value being assigned to this leaf must be strictly lower than the current value of leaf alarmAntiFloodingHighWater.rw INTEGER .1.3.6.1.4.1.3373.1103.4.31 |
alarmItemTableTable with record of available alarms in the NE. This table reports every created alarm in the NE. SEQUENCE OF AlarmRecord .1.3.6.1.4.1.3373.1103.4.32 |
alarmRecordAlarm record. AlarmRecord .1.3.6.1.4.1.3373.1103.4.32.1 |
alarmOidThe Object Identifier of the Managed Object with Alarms or Controls active (not cleared Alarm Status).ro OBJECT IDENTIFIER .1.3.6.1.4.1.3373.1103.4.32.1.1 |
alarmDescriptionASCII string used to describe the alarm.ro DisplayString .1.3.6.1.4.1.3373.1103.4.32.1.2 |