Home/Catalog/SIAE-PMTXPWR-MIB

SIAE-PMTXPWR-MIB

Performance Monitoring on Transmitted (TX) RF Power.
Main OID:
pmTxPwr.1.3.6.1.4.1.3373.1103.13
49
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

49 total
Object Name
pmTxPwrPerformance Monitoring on Transmitted (TX) RF Power.
MODULE-IDENTITY
.1.3.6.1.4.1.3373.1103.13
pmTxPwrMibVersionNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.ro
INTEGER
.1.3.6.1.4.1.3373.1103.13.1
pmTxPwrCounterTableTable with PmTxPwr records: one record for 1+0 configuration and two record for 1+1 configuration.
SEQUENCE OF PmTxPwrCounterRecord
.1.3.6.1.4.1.3373.1103.13.2
pmTxPwrCounterRecordPmTxPwrCounter record.
PmTxPwrCounterRecord
.1.3.6.1.4.1.3373.1103.13.2.1
pmTxPwrBranchIdThis object identifies the Radio Branchro
Integer32
.1.3.6.1.4.1.3373.1103.13.2.1.1
pmTxPwrCounterBlockIdThis object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 19 15 minutes counters N. 16 (The oldest 15 minutes counters - 4 hours before).ro
Integer32
.1.3.6.1.4.1.3373.1103.13.2.1.2
pmTxPwrCounterBlockTypeThe type of the counter block.ro
Enumeration
.1.3.6.1.4.1.3373.1103.13.2.1.3
pmTxPwrCounterBlockStatusblock counter status.ro
Enumeration
.1.3.6.1.4.1.3373.1103.13.2.1.4
pmTxPwrCounterTimeStampThe object is the time when the performance record is closed reported as the second number since 1-Gen-1970.ro
Unsigned32
.1.3.6.1.4.1.3373.1103.13.2.1.5
pmTxPwrTlts1CounterNumber of seconds when the Transmitted power is greater than the threshold 1.ro
Counter32
.1.3.6.1.4.1.3373.1103.13.2.1.6
pmTxPwrTlts2CounterNumber of seconds when the Transmitted power is greater than the threshold 2ro
Counter32
.1.3.6.1.4.1.3373.1103.13.2.1.7
pmTxPwrTlts3CounterNumber of seconds when the Transmitted power is greater than the threshold 3ro
Counter32
.1.3.6.1.4.1.3373.1103.13.2.1.8
pmTxPwrTlts4CounterNumber of seconds when the Transmitted power is greater than the threshold 4ro
Counter32
.1.3.6.1.4.1.3373.1103.13.2.1.9
pmTxPwrTMMaxMaximum Transmitted Power Level Tide Mark.ro
Integer32
.1.3.6.1.4.1.3373.1103.13.2.1.10
pmTxPwrTMMinMinimum Transmitted Power Level Tide Mark.ro
Integer32
.1.3.6.1.4.1.3373.1103.13.2.1.11
pmTxPwrAverageTxLevelPower Transmitted Level (Average value)ro
Integer32
.1.3.6.1.4.1.3373.1103.13.2.1.12
pmTxPwrTpClassTableTable with PmTxPwrTpClass records: one record for 1+0 configuration and two record for 1+1 configuration.
SEQUENCE OF PmTxPwrTpClassRecord
.1.3.6.1.4.1.3373.1103.13.3
pmTxPwrTpClassRecordPmTxPwrTpClass record.
PmTxPwrTpClassRecord
.1.3.6.1.4.1.3373.1103.13.3.1
pmTxPwrTpClassBranchIdThis object identifies the Radio Branchro
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.1
pmTxPwrTpClassStartStopThis object is used to start and to stop the Perfomance Monitoring counter evaluation.rw
Enumeration
.1.3.6.1.4.1.3373.1103.13.3.1.2
pmTxPwrTpClassLabelASCII string used to identify the Tp class: pmTxPwrTpClassBranchId = 1 label = Radio 1 pmTxPwrTpClassBranchId = 2 label = Radio 2.ro
DisplayString
.1.3.6.1.4.1.3373.1103.13.3.1.3
pmTxPwrTpClassTimeStampThe object is the time when the performance record is closed reported as the second number since 1/1/70.ro
Unsigned32
.1.3.6.1.4.1.3373.1103.13.3.1.4
pmTxPwrTpClass15MTlts1Alarm15 minutes Tlts1 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.5
pmTxPwrTpClass15MTlts2Alarm15 minutes Tlts2 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.6
pmTxPwrTpClass15MTlts3Alarm15 minutes Tlts3 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.7
pmTxPwrTpClass15MTlts4Alarm15 minutes Tlts4 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.8
pmTxPwrTpClass24HTlts1AlarmDaily Tlts1 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.9
pmTxPwrTpClass24HTlts2AlarmDaily Tlts2 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.10
pmTxPwrTpClass24HTlts3AlarmDaily Tlts3 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.11
pmTxPwrTpClass24HTlts4AlarmDaily Tlts4 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.12
pmTxPwrTpClassTlt1ThresholdReceived Power Level Threshold 1 (dBm value); range -100 to -20rw
INTEGER (-100..-20)
.1.3.6.1.4.1.3373.1103.13.3.1.13
pmTxPwrTpClassTlt2ThresholdReceived Power Level Threshold 2 (dBm value); range -100 to -20rw
INTEGER (-100..-20)
.1.3.6.1.4.1.3373.1103.13.3.1.14
pmTxPwrTpClassTlt3ThresholdReceived Power Level Threshold 3 (dBm value); range -100 to -20rw
INTEGER (-100..-20)
.1.3.6.1.4.1.3373.1103.13.3.1.15
pmTxPwrTpClassTlt4ThresholdReceived Power Level Threshold 4 (dBm value); range -100 to -20rw
INTEGER (-100..-20)
.1.3.6.1.4.1.3373.1103.13.3.1.16
pmTxPwrTpClass15MTlts1ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts1Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.17
pmTxPwrTpClass15MTlts2ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts2Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.18
pmTxPwrTpClass15MTlts3ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts3Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.19
pmTxPwrTpClass15MTlts4ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts4Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.20
pmTxPwrTpClass24HTlts1ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts1Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.21
pmTxPwrTpClass24HTlts2ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts2Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.22
pmTxPwrTpClass24HTlts3ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts3Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.23
pmTxPwrTpClass24HTlts4ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts4Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.24
pmTxPwrTpClassRowStatusStatus of this row of pmTxPwrTpClass.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.3373.1103.13.3.1.25
pmTxPwrTpMaintTableTable with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmTxPwrTpClassTable
SEQUENCE OF PmTxPwrTpMaintRecord
.1.3.6.1.4.1.3373.1103.13.4
pmTxPwrTpMaintRecordPmG828 Termination Point Maintenance record.
PmTxPwrTpMaintRecord
.1.3.6.1.4.1.3373.1103.13.4.1
pmTxPwrTpMaintCounterClearThis object is used to clear the Perfomance Monitoring counters.rw
Enumeration
.1.3.6.1.4.1.3373.1103.13.4.1.1
pmTxPwrTpMaintAlarmClearThis object is used to clear the Perfomance Monitoring threshold cross alarms.rw
Enumeration
.1.3.6.1.4.1.3373.1103.13.4.1.2
pmTxPwrTpClass15MTltsAlarmSeverityCodeDefine the severity associated to the pmTxPwrTpClass15MTltsAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.5
pmTxPwrTpClass24HTltsAlarmSeverityCodeDefine the severity associated to the pmTxPwrTpClass24HTltsAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.6