SIAE-PMTXPWR-MIB
Performance Monitoring on Transmitted (TX) RF Power.
Main OID:
pmTxPwr.1.3.6.1.4.1.3373.1103.13
49
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
49 total| Object Name |
|---|
pmTxPwrPerformance Monitoring on Transmitted (TX) RF Power. MODULE-IDENTITY .1.3.6.1.4.1.3373.1103.13 |
pmTxPwrMibVersionNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.ro INTEGER .1.3.6.1.4.1.3373.1103.13.1 |
pmTxPwrCounterTableTable with PmTxPwr records: one record for 1+0 configuration and two record for 1+1 configuration. SEQUENCE OF PmTxPwrCounterRecord .1.3.6.1.4.1.3373.1103.13.2 |
pmTxPwrCounterRecordPmTxPwrCounter record. PmTxPwrCounterRecord .1.3.6.1.4.1.3373.1103.13.2.1 |
pmTxPwrBranchIdThis object identifies the Radio Branchro Integer32 .1.3.6.1.4.1.3373.1103.13.2.1.1 |
pmTxPwrCounterBlockIdThis object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 19 15 minutes counters N. 16 (The oldest 15 minutes counters - 4 hours before).ro Integer32 .1.3.6.1.4.1.3373.1103.13.2.1.2 |
pmTxPwrCounterBlockTypeThe type of the counter block.ro Enumeration .1.3.6.1.4.1.3373.1103.13.2.1.3 |
pmTxPwrCounterBlockStatusblock counter status.ro Enumeration .1.3.6.1.4.1.3373.1103.13.2.1.4 |
pmTxPwrCounterTimeStampThe object is the time when the performance record is closed reported as the second number since 1-Gen-1970.ro Unsigned32 .1.3.6.1.4.1.3373.1103.13.2.1.5 |
pmTxPwrTlts1CounterNumber of seconds when the Transmitted power is greater than the threshold 1.ro Counter32 .1.3.6.1.4.1.3373.1103.13.2.1.6 |
pmTxPwrTlts2CounterNumber of seconds when the Transmitted power is greater than the threshold 2ro Counter32 .1.3.6.1.4.1.3373.1103.13.2.1.7 |
pmTxPwrTlts3CounterNumber of seconds when the Transmitted power is greater than the threshold 3ro Counter32 .1.3.6.1.4.1.3373.1103.13.2.1.8 |
pmTxPwrTlts4CounterNumber of seconds when the Transmitted power is greater than the threshold 4ro Counter32 .1.3.6.1.4.1.3373.1103.13.2.1.9 |
pmTxPwrTMMaxMaximum Transmitted Power Level Tide Mark.ro Integer32 .1.3.6.1.4.1.3373.1103.13.2.1.10 |
pmTxPwrTMMinMinimum Transmitted Power Level Tide Mark.ro Integer32 .1.3.6.1.4.1.3373.1103.13.2.1.11 |
pmTxPwrAverageTxLevelPower Transmitted Level (Average value)ro Integer32 .1.3.6.1.4.1.3373.1103.13.2.1.12 |
pmTxPwrTpClassTableTable with PmTxPwrTpClass records: one record for 1+0 configuration and two record for 1+1 configuration. SEQUENCE OF PmTxPwrTpClassRecord .1.3.6.1.4.1.3373.1103.13.3 |
pmTxPwrTpClassRecordPmTxPwrTpClass record. PmTxPwrTpClassRecord .1.3.6.1.4.1.3373.1103.13.3.1 |
pmTxPwrTpClassBranchIdThis object identifies the Radio Branchro Integer32 .1.3.6.1.4.1.3373.1103.13.3.1.1 |
pmTxPwrTpClassStartStopThis object is used to start and to stop the Perfomance Monitoring counter evaluation.rw Enumeration .1.3.6.1.4.1.3373.1103.13.3.1.2 |
pmTxPwrTpClassLabelASCII string used to identify the Tp class: pmTxPwrTpClassBranchId = 1 label = Radio 1 pmTxPwrTpClassBranchId = 2 label = Radio 2.ro DisplayString .1.3.6.1.4.1.3373.1103.13.3.1.3 |
pmTxPwrTpClassTimeStampThe object is the time when the performance record is closed reported as the second number since 1/1/70.ro Unsigned32 .1.3.6.1.4.1.3373.1103.13.3.1.4 |
pmTxPwrTpClass15MTlts1Alarm15 minutes Tlts1 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.13.3.1.5 |
pmTxPwrTpClass15MTlts2Alarm15 minutes Tlts2 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.13.3.1.6 |
pmTxPwrTpClass15MTlts3Alarm15 minutes Tlts3 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.13.3.1.7 |
pmTxPwrTpClass15MTlts4Alarm15 minutes Tlts4 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.13.3.1.8 |
pmTxPwrTpClass24HTlts1AlarmDaily Tlts1 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.13.3.1.9 |
pmTxPwrTpClass24HTlts2AlarmDaily Tlts2 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.13.3.1.10 |
pmTxPwrTpClass24HTlts3AlarmDaily Tlts3 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.13.3.1.11 |
pmTxPwrTpClass24HTlts4AlarmDaily Tlts4 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.13.3.1.12 |
pmTxPwrTpClassTlt1ThresholdReceived Power Level Threshold 1 (dBm value); range -100 to -20rw INTEGER (-100..-20) .1.3.6.1.4.1.3373.1103.13.3.1.13 |
pmTxPwrTpClassTlt2ThresholdReceived Power Level Threshold 2 (dBm value); range -100 to -20rw INTEGER (-100..-20) .1.3.6.1.4.1.3373.1103.13.3.1.14 |
pmTxPwrTpClassTlt3ThresholdReceived Power Level Threshold 3 (dBm value); range -100 to -20rw INTEGER (-100..-20) .1.3.6.1.4.1.3373.1103.13.3.1.15 |
pmTxPwrTpClassTlt4ThresholdReceived Power Level Threshold 4 (dBm value); range -100 to -20rw INTEGER (-100..-20) .1.3.6.1.4.1.3373.1103.13.3.1.16 |
pmTxPwrTpClass15MTlts1ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts1Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.13.3.1.17 |
pmTxPwrTpClass15MTlts2ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts2Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.13.3.1.18 |
pmTxPwrTpClass15MTlts3ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts3Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.13.3.1.19 |
pmTxPwrTpClass15MTlts4ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts4Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.13.3.1.20 |
pmTxPwrTpClass24HTlts1ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts1Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.13.3.1.21 |
pmTxPwrTpClass24HTlts2ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts2Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.13.3.1.22 |
pmTxPwrTpClass24HTlts3ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts3Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.13.3.1.23 |
pmTxPwrTpClass24HTlts4ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts4Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.13.3.1.24 |
pmTxPwrTpClassRowStatusStatus of this row of pmTxPwrTpClass.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3373.1103.13.3.1.25 |
pmTxPwrTpMaintTableTable with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmTxPwrTpClassTable SEQUENCE OF PmTxPwrTpMaintRecord .1.3.6.1.4.1.3373.1103.13.4 |
pmTxPwrTpMaintRecordPmG828 Termination Point Maintenance record. PmTxPwrTpMaintRecord .1.3.6.1.4.1.3373.1103.13.4.1 |
pmTxPwrTpMaintCounterClearThis object is used to clear the Perfomance Monitoring counters.rw Enumeration .1.3.6.1.4.1.3373.1103.13.4.1.1 |
pmTxPwrTpMaintAlarmClearThis object is used to clear the Perfomance Monitoring threshold cross alarms.rw Enumeration .1.3.6.1.4.1.3373.1103.13.4.1.2 |
pmTxPwrTpClass15MTltsAlarmSeverityCodeDefine the severity associated to the pmTxPwrTpClass15MTltsAlarm and enables/disables the trap generation on status change event.rw AlarmSeverityCode (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.13.5 |
pmTxPwrTpClass24HTltsAlarmSeverityCodeDefine the severity associated to the pmTxPwrTpClass24HTltsAlarm and enables/disables the trap generation on status change event.rw AlarmSeverityCode (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.13.6 |