Home/Catalog/SIAE-PMTXPWR-MIB

SIAE-PMTXPWR-MIB

AI MIB Summary

The SIAE-PMTXPWR-MIB module enables the monitoring of transmitted RF power metrics on SIAE microwave radio equipment via SNMP. It provides specific performance counters and gauges for tracking the output power levels of active RF transmission channels to ensure signal integrity and link stability.

Performance Monitoring on Transmitted (TX) RF Power.
Main OID:
pmTxPwr.1.3.6.1.4.1.3373.1103.13
49
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

49 total
Object Name
pmTxPwrPerformance Monitoring on Transmitted (TX) RF Power.
MODULE-IDENTITY
.1.3.6.1.4.1.3373.1103.13
pmTxPwrMibVersionNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.ro
INTEGER
.1.3.6.1.4.1.3373.1103.13.1
pmTxPwrCounterTableTable with PmTxPwr records: one record for 1+0 configuration and two record for 1+1 configuration.
SEQUENCE OF PmTxPwrCounterRecord
.1.3.6.1.4.1.3373.1103.13.2
pmTxPwrCounterRecordPmTxPwrCounter record.
PmTxPwrCounterRecord
.1.3.6.1.4.1.3373.1103.13.2.1
pmTxPwrBranchIdThis object identifies the Radio Branchro
Integer32
.1.3.6.1.4.1.3373.1103.13.2.1.1
pmTxPwrCounterBlockIdThis object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 19 15 minutes counters N. 16 (The oldest 15 minutes counters - 4 hours before).ro
Integer32
.1.3.6.1.4.1.3373.1103.13.2.1.2
pmTxPwrCounterBlockTypeThe type of the counter block.ro
Enumeration
.1.3.6.1.4.1.3373.1103.13.2.1.3
pmTxPwrCounterBlockStatusblock counter status.ro
Enumeration
.1.3.6.1.4.1.3373.1103.13.2.1.4
pmTxPwrCounterTimeStampThe object is the time when the performance record is closed reported as the second number since 1-Gen-1970.ro
Unsigned32
.1.3.6.1.4.1.3373.1103.13.2.1.5
pmTxPwrTlts1CounterNumber of seconds when the Transmitted power is greater than the threshold 1.ro
Counter32
.1.3.6.1.4.1.3373.1103.13.2.1.6
pmTxPwrTlts2CounterNumber of seconds when the Transmitted power is greater than the threshold 2ro
Counter32
.1.3.6.1.4.1.3373.1103.13.2.1.7
pmTxPwrTlts3CounterNumber of seconds when the Transmitted power is greater than the threshold 3ro
Counter32
.1.3.6.1.4.1.3373.1103.13.2.1.8
pmTxPwrTlts4CounterNumber of seconds when the Transmitted power is greater than the threshold 4ro
Counter32
.1.3.6.1.4.1.3373.1103.13.2.1.9
pmTxPwrTMMaxMaximum Transmitted Power Level Tide Mark.ro
Integer32
.1.3.6.1.4.1.3373.1103.13.2.1.10
pmTxPwrTMMinMinimum Transmitted Power Level Tide Mark.ro
Integer32
.1.3.6.1.4.1.3373.1103.13.2.1.11
pmTxPwrAverageTxLevelPower Transmitted Level (Average value)ro
Integer32
.1.3.6.1.4.1.3373.1103.13.2.1.12
pmTxPwrTpClassTableTable with PmTxPwrTpClass records: one record for 1+0 configuration and two record for 1+1 configuration.
SEQUENCE OF PmTxPwrTpClassRecord
.1.3.6.1.4.1.3373.1103.13.3
pmTxPwrTpClassRecordPmTxPwrTpClass record.
PmTxPwrTpClassRecord
.1.3.6.1.4.1.3373.1103.13.3.1
pmTxPwrTpClassBranchIdThis object identifies the Radio Branchro
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.1
pmTxPwrTpClassStartStopThis object is used to start and to stop the Perfomance Monitoring counter evaluation.rw
Enumeration
.1.3.6.1.4.1.3373.1103.13.3.1.2
pmTxPwrTpClassLabelASCII string used to identify the Tp class: pmTxPwrTpClassBranchId = 1 label = Radio 1 pmTxPwrTpClassBranchId = 2 label = Radio 2.ro
DisplayString
.1.3.6.1.4.1.3373.1103.13.3.1.3
pmTxPwrTpClassTimeStampThe object is the time when the performance record is closed reported as the second number since 1/1/70.ro
Unsigned32
.1.3.6.1.4.1.3373.1103.13.3.1.4
pmTxPwrTpClass15MTlts1Alarm15 minutes Tlts1 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.5
pmTxPwrTpClass15MTlts2Alarm15 minutes Tlts2 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.6
pmTxPwrTpClass15MTlts3Alarm15 minutes Tlts3 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.7
pmTxPwrTpClass15MTlts4Alarm15 minutes Tlts4 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.8
pmTxPwrTpClass24HTlts1AlarmDaily Tlts1 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.9
pmTxPwrTpClass24HTlts2AlarmDaily Tlts2 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.10
pmTxPwrTpClass24HTlts3AlarmDaily Tlts3 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.11
pmTxPwrTpClass24HTlts4AlarmDaily Tlts4 threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.3.1.12
pmTxPwrTpClassTlt1ThresholdReceived Power Level Threshold 1 (dBm value); range -100 to -20rw
INTEGER (-100..-20)
.1.3.6.1.4.1.3373.1103.13.3.1.13
pmTxPwrTpClassTlt2ThresholdReceived Power Level Threshold 2 (dBm value); range -100 to -20rw
INTEGER (-100..-20)
.1.3.6.1.4.1.3373.1103.13.3.1.14
pmTxPwrTpClassTlt3ThresholdReceived Power Level Threshold 3 (dBm value); range -100 to -20rw
INTEGER (-100..-20)
.1.3.6.1.4.1.3373.1103.13.3.1.15
pmTxPwrTpClassTlt4ThresholdReceived Power Level Threshold 4 (dBm value); range -100 to -20rw
INTEGER (-100..-20)
.1.3.6.1.4.1.3373.1103.13.3.1.16
pmTxPwrTpClass15MTlts1ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts1Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.17
pmTxPwrTpClass15MTlts2ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts2Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.18
pmTxPwrTpClass15MTlts3ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts3Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.19
pmTxPwrTpClass15MTlts4ThresholdNumber of seconds within 15 minutes to set pmTxPwrTpClass15MTlts4Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.20
pmTxPwrTpClass24HTlts1ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts1Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.21
pmTxPwrTpClass24HTlts2ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts2Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.22
pmTxPwrTpClass24HTlts3ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts3Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.23
pmTxPwrTpClass24HTlts4ThresholdNumber of seconds within a day to set pmTxPwrTpClass24HTlts4Alarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.13.3.1.24
pmTxPwrTpClassRowStatusStatus of this row of pmTxPwrTpClass.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.3373.1103.13.3.1.25
pmTxPwrTpMaintTableTable with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmTxPwrTpClassTable
SEQUENCE OF PmTxPwrTpMaintRecord
.1.3.6.1.4.1.3373.1103.13.4
pmTxPwrTpMaintRecordPmG828 Termination Point Maintenance record.
PmTxPwrTpMaintRecord
.1.3.6.1.4.1.3373.1103.13.4.1
pmTxPwrTpMaintCounterClearThis object is used to clear the Perfomance Monitoring counters.rw
Enumeration
.1.3.6.1.4.1.3373.1103.13.4.1.1
pmTxPwrTpMaintAlarmClearThis object is used to clear the Perfomance Monitoring threshold cross alarms.rw
Enumeration
.1.3.6.1.4.1.3373.1103.13.4.1.2
pmTxPwrTpClass15MTltsAlarmSeverityCodeDefine the severity associated to the pmTxPwrTpClass15MTltsAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.5
pmTxPwrTpClass24HTltsAlarmSeverityCodeDefine the severity associated to the pmTxPwrTpClass24HTltsAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.13.6

More MIBs from SIAE MICROELETTRONICA spa

Browse all SIAE MICROELETTRONICA spaMIBs →
SIAE-RADIO-SYSTEM-MIB

The SIAE-RADIO-SYSTEM-MIB facilitates the monitoring and management of SIAE radio transmission infrastructure, specifically exposing performance metrics such as RF link status, signal strength, error rates, and system health indicators for broadcast and telecommunications equipment.

369 objects→
SIAE-PTP-MIB

The SIAE-PTP-MIB module enables monitoring and management of SIAE hardware devices implementing the IEEE 1588-2008 Precision Time Protocol and ITU-T G.8275.1 telecom profile, specifically exposing metrics for clock synchronization states, grandmaster selection, and phase/time offset measurements.

139 objects→
SIAE-SYNC-MIB

The SIAE-SYNC-MIB module manages timing source configuration and synchronization states for SIAE broadcast infrastructure equipment, monitoring critical metrics such as reference clock status, synchronization lock status, and time deviation values to ensure precise frame and data alignment.

73 objects→
SIAE-ALARM-MIB

The SIAE-ALARM-MIB module enables the monitoring of network element alarm state transitions and the retrieval of active alarm entries via SNMP for SIAE-managed infrastructure. It specifically tracks alarm severity, timestamp, and status changes to facilitate real-time fault detection and event logging.

58 objects→
SIAE-SFP-MIB

The SIAE-SFP-MIB enables SNMP-based monitoring and alarm generation for SIAE Small Form-Factor Pluggable optical transceivers, exposing diagnostic parameters defined by SFF-8472 such as temperature, supply voltage, laser bias current, and optical transmit/receive power levels.

56 objects→
SIAE-PMRXPWR-MIB

The SIAE-PMRXPWR-MIB module enables SNMP-based monitoring of received RF power levels within SIAE microwave radio systems, specifically tracking performance metrics such as instantaneous and average RX signal strength to assess link quality and detect signal degradation.

55 objects→