SIAE-PMRXPWR-MIB
AI MIB Summary
The SIAE-PMRXPWR-MIB module enables SNMP-based monitoring of received RF power levels within SIAE microwave radio systems, specifically tracking performance metrics such as instantaneous and average RX signal strength to assess link quality and detect signal degradation.
Performance Monitoring on Received (RX) RF Power.
Main OID:
pmRxPwr.1.3.6.1.4.1.3373.1103.12
55
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
55 total| Object Name |
|---|
pmRxPwrPerformance Monitoring on Received (RX) RF Power. MODULE-IDENTITY .1.3.6.1.4.1.3373.1103.12 |
pmRxPwrMibVersionNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.ro INTEGER .1.3.6.1.4.1.3373.1103.12.1 |
pmRxPwrCounterTableTable with PmRxPwr records: one record for 1+0 configuration and two record for 1+1 configuration. SEQUENCE OF PmRxPwrCounterRecord .1.3.6.1.4.1.3373.1103.12.2 |
pmRxPwrCounterRecordPmRxPwrCounter record. PmRxPwrCounterRecord .1.3.6.1.4.1.3373.1103.12.2.1 |
pmRxPwrBranchIdThis object identifies the Radio Branchro Integer32 .1.3.6.1.4.1.3373.1103.12.2.1.1 |
pmRxPwrCounterBlockIdThis object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 20 15 minutes counters N.16(The oldest 15 min. counters 4 hours before).ro Integer32 .1.3.6.1.4.1.3373.1103.12.2.1.2 |
pmRxPwrCounterBlockTypeThe type of the counter block.ro Enumeration .1.3.6.1.4.1.3373.1103.12.2.1.3 |
pmRxPwrCounterBlockStatusStatus of the block counter.ro Enumeration .1.3.6.1.4.1.3373.1103.12.2.1.4 |
pmRxPwrCounterTimeStampThe object is the time when the performance record is closed reported as the second number since 1-Gen-1970.ro Unsigned32 .1.3.6.1.4.1.3373.1103.12.2.1.5 |
pmRxPwrRlts1CounterNumber of seconds when the Received power is less than the threshold 1.ro Counter32 .1.3.6.1.4.1.3373.1103.12.2.1.6 |
pmRxPwrRlts2CounterNumber of seconds when the Received power is less than the threshold 2ro Counter32 .1.3.6.1.4.1.3373.1103.12.2.1.7 |
pmRxPwrRlts3CounterNumber of seconds when the Received power is less than the threshold 3ro Counter32 .1.3.6.1.4.1.3373.1103.12.2.1.8 |
pmRxPwrRlts4CounterNumber of seconds when the Received power is less than the threshold 4ro Counter32 .1.3.6.1.4.1.3373.1103.12.2.1.9 |
pmRxPwrRlts5CounterNumber of seconds when the Received power is less than the threshold 5ro Counter32 .1.3.6.1.4.1.3373.1103.12.2.1.10 |
pmRxPwrTMMaxMaximum Power Received Level Tide Mark.ro Integer32 .1.3.6.1.4.1.3373.1103.12.2.1.11 |
pmRxPwrTMMinMinimum Power Received Level Tide Mark.ro Integer32 .1.3.6.1.4.1.3373.1103.12.2.1.12 |
pmRxPwrAverageRxLevelPower Received Level (Average value)ro Integer32 .1.3.6.1.4.1.3373.1103.12.2.1.13 |
pmRxPwrTpClassTableTable with PmRxPwrTpClass records: one record for 1+0 configuration and two record for 1+1 configuration. SEQUENCE OF PmRxPwrTpClassRecord .1.3.6.1.4.1.3373.1103.12.3 |
pmRxPwrTpClassRecordPmRxPwrTpClass record. PmRxPwrTpClassRecord .1.3.6.1.4.1.3373.1103.12.3.1 |
pmRxPwrTpClassBranchIdThis object identifies the Radio Branchro Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.1 |
pmRxPwrTpClassStartStopThis object is used to start and to stop the Perfomance Monitoring counter evaluation.rw Enumeration .1.3.6.1.4.1.3373.1103.12.3.1.2 |
pmRxPwrTpClassLabelASCII string used to identify the Tp class: pmRxPwrTpClassBranchId = 1 label = Radio 1 pmRxPwrTpClassBranchId = 2 label = Radio 2.ro DisplayString .1.3.6.1.4.1.3373.1103.12.3.1.3 |
pmRxPwrTpClassTimeStampThe object is the time when the performance record is closed reported as the second number since 1/1/70.ro Unsigned32 .1.3.6.1.4.1.3373.1103.12.3.1.4 |
pmRxPwrTpClass15MRlts1Alarm15 minutes Rlts1 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.3.1.5 |
pmRxPwrTpClass15MRlts2Alarm15 minutes Rlts2 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.3.1.6 |
pmRxPwrTpClass15MRlts3Alarm15 minutes Rlts3 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.3.1.7 |
pmRxPwrTpClass15MRlts4Alarm15 minutes Rlts4 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.3.1.8 |
pmRxPwrTpClass15MRlts5Alarm15 minutes Rlts5 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.3.1.9 |
pmRxPwrTpClass24HRlts1AlarmDaily Rlts1 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.3.1.10 |
pmRxPwrTpClass24HRlts2AlarmDaily Rlts2 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.3.1.11 |
pmRxPwrTpClass24HRlts3AlarmDaily Rlts3 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.3.1.12 |
pmRxPwrTpClass24HRlts4AlarmDaily Rlts4 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.3.1.13 |
pmRxPwrTpClass24HRlts5AlarmDaily Rlts5 threshold cross alarm with associated severity.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.3.1.14 |
pmRxPwrTpClassRlt1ThresholdReceived Power Level Threshold 1 (dBm value); range -100 to -20rw INTEGER (-100..-20) .1.3.6.1.4.1.3373.1103.12.3.1.15 |
pmRxPwrTpClassRlt2ThresholdReceived Power Level Threshold 2 (dBm value); range -100 to -20rw INTEGER (-100..-20) .1.3.6.1.4.1.3373.1103.12.3.1.16 |
pmRxPwrTpClassRlt3ThresholdReceived Power Level Threshold 3 (dBm value); range -100 to -20rw INTEGER (-100..-20) .1.3.6.1.4.1.3373.1103.12.3.1.17 |
pmRxPwrTpClassRlt4ThresholdReceived Power Level Threshold 4 (dBm value); range -100 to -20rw INTEGER (-100..-20) .1.3.6.1.4.1.3373.1103.12.3.1.18 |
pmRxPwrTpClassRlt5ThresholdReceived Power Level Threshold 5 (dBm value); range -100 to -20rw INTEGER (-100..-20) .1.3.6.1.4.1.3373.1103.12.3.1.19 |
pmRxPwrTpClass15MRlts1ThresholdNumber of seconds within 15 minutes to set pmRxPwrTpClass15MRlts1Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.20 |
pmRxPwrTpClass15MRlts2ThresholdNumber of seconds within 15 minutes to set pmRxPwrTpClass15MRlts2Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.21 |
pmRxPwrTpClass15MRlts3ThresholdNumber of seconds within 15 minutes to set pmRxPwrTpClass15MRlts3Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.22 |
pmRxPwrTpClass15MRlts4ThresholdNumber of seconds within 15 minutes to set pmRxPwrTpClass15MRlts4Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.23 |
pmRxPwrTpClass15MRlts5ThresholdNumber of seconds within 15 minutes to set pmRxPwrTpClass15MRlts5Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.24 |
pmRxPwrTpClass24HRlts1ThresholdNumber of seconds within a day to set pmRxPwrTpClass24HRlts1Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.25 |
pmRxPwrTpClass24HRlts2ThresholdNumber of seconds within a day to set pmRxPwrTpClass24HRlts2Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.26 |
pmRxPwrTpClass24HRlts3ThresholdNumber of seconds within a day to set pmRxPwrTpClass24HRlts3Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.27 |
pmRxPwrTpClass24HRlts4ThresholdNumber of seconds within a day to set pmRxPwrTpClass24HRlts4Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.28 |
pmRxPwrTpClass24HRlts5ThresholdNumber of seconds within a day to set pmRxPwrTpClass24HRlts5Alarm (zero value disables the alarm).rw Integer32 .1.3.6.1.4.1.3373.1103.12.3.1.29 |
pmRxPwrTpClassRowStatusStatus of this row of pmRxPwrTpClass.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3373.1103.12.3.1.30 |
pmRxPwrTpMaintTableTable with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmRxPwrTpClassTable SEQUENCE OF PmRxPwrTpMaintRecord .1.3.6.1.4.1.3373.1103.12.4 |
pmRxPwrTpMaintRecordPmG828 Termination Point Maintenance record. PmRxPwrTpMaintRecord .1.3.6.1.4.1.3373.1103.12.4.1 |
pmRxPwrTpMaintCounterClearThis object is used to clear the Perfomance Monitoring counters.rw Enumeration .1.3.6.1.4.1.3373.1103.12.4.1.1 |
pmRxPwrTpMaintAlarmClearThis object is used to clear the Perfomance Monitoring threshold cross alarms.rw Enumeration .1.3.6.1.4.1.3373.1103.12.4.1.2 |
pmRxPwrTpClass15MRltsAlarmSeverityCodeDefine the severity associated to the pmRxPwrTpClass15MRltsAlarm and enables/disables the trap generation on status change event.rw AlarmSeverityCode (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.5 |
pmRxPwrTpClass24HRltsAlarmSeverityCodeDefine the severity associated to the pmRxPwrTpClass24HRltsAlarm and enables/disables the trap generation on status change event.rw AlarmSeverityCode (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.12.6 |