HM2-PWRMGMT-MIB
The HM2-PWRMGMT-MIB enables SNMP-based monitoring and control of power supply units, voltage levels, current consumption, and fan status on Hirschmann (Belden) network switches. This module facilitates granular visibility into power redundancy states and environmental power metrics for infrastructure availability management.
Imported Objects
Objects
32 total| Object Name |
|---|
hm2PowerMgmtMibHirschmann Power Management MIB. Copyright (C) 2011. All Rights Reserved. MODULE-IDENTITY .1.3.6.1.4.1.248.11.11 |
hm2PowerMgmtMibNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.248.11.11.0 |
hm2PowerSupplyTrapThis trap is sent when the value of hm2PSState has been changed. NOTIFICATION-TYPE .1.3.6.1.4.1.248.11.11.0.1 |
hm2PowerMgmtMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.248.11.11.1 |
hm2PowerSupplyGroup OBJECT IDENTIFIER .1.3.6.1.4.1.248.11.11.1.1 |
hm2PSTableThis table contains all variables related to the power supply units of the chassis/switch. For each power supply slot exists one instance. SEQUENCE OF Hm2PSEntry .1.3.6.1.4.1.248.11.11.1.1.1 |
hm2PSEntryThe entry of the hm2PSTable. Hm2PSEntry .1.3.6.1.4.1.248.11.11.1.1.1.1 |
hm2PSIDThis index is used to identify the associated power supply unit.ro Integer32 .1.3.6.1.4.1.248.11.11.1.1.1.1.1 |
hm2PSStateIndicates the operational state of the associated power supply. If the value of this variable changes, a hm2PowerSupply trap is sent.ro Enumeration .1.3.6.1.4.1.248.11.11.1.1.1.1.2 |
hm2PSUSlotInfoTableThis table contains all EEPROM variables related to the power supply slot modules of the chassis/switch. For each power supply slot module exists one instance. SEQUENCE OF Hm2PSUSlotInfoEntry .1.3.6.1.4.1.248.11.11.1.1.10 |
hm2PSUSlotInfoEntryThe entry of the hm2PSUSlotInfoTable. Hm2PSUSlotInfoEntry .1.3.6.1.4.1.248.11.11.1.1.10.1 |
hm2PSUSlotIndexThis index is used to identify the associated power supply slot module. Integer32 .1.3.6.1.4.1.248.11.11.1.1.10.1.1 |
hm2PSUSlotChassisTypeIdThe chassis type id of the associated power supply slot module.ro Enumeration .1.3.6.1.4.1.248.11.11.1.1.10.1.2 |
hm2PSUSlotManufacturerIdThe manufacturer id of the associated power supply slot module.ro Enumeration .1.3.6.1.4.1.248.11.11.1.1.10.1.3 |
hm2PSUSlotManufacturerDateThe manufacturer date of the associated power supply slot module. *** NOTE this is set to OBSOLETE ***roobsolete SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.248.11.11.1.1.10.1.4 |
hm2PSUSlotSerialNumberThe serial number of the associated power supply slot module.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.248.11.11.1.1.10.1.5 |
hm2PSUSlotProductCodeThe product code of the associated power supply slot module.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.248.11.11.1.1.10.1.6 |
hm2PSUSlotDescriptionThe description of the associated power supply slot module.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.248.11.11.1.1.10.1.7 |
hm2PSUSlotCombinationTypeThe combination type of the associated power supply slot module.ro Enumeration .1.3.6.1.4.1.248.11.11.1.1.10.1.8 |
hm2PSUSlotTemperatureRangeThe temperature range of the associated power supply slot module.ro Enumeration .1.3.6.1.4.1.248.11.11.1.1.10.1.9 |
hm2PSUSlotRevisionIdHardware revision of the PSUro Integer32 .1.3.6.1.4.1.248.11.11.1.1.10.1.10 |
hm2PSUUnitInfoTableThis table contains all EEPROM variables related to the power supply slot module units. For each power supply slot module exists up to two instances. SEQUENCE OF Hm2PSUUnitInfoEntry .1.3.6.1.4.1.248.11.11.1.1.20 |
hm2PSUUnitInfoEntryThe entry of the hm2PSUUnitInfoTable. Hm2PSUUnitInfoEntry .1.3.6.1.4.1.248.11.11.1.1.20.1 |
hm2PSUUnitIndexThe number of PSU units on the associated power supply slot module. Integer32 .1.3.6.1.4.1.248.11.11.1.1.20.1.1 |
hm2PSUUnitConverterTypeThe converter type of the associated power supply slot module unit.ro Enumeration .1.3.6.1.4.1.248.11.11.1.1.20.1.2 |
hm2PSUUnitNumberOfInputsThe number of inputs of the associated power supply slot module unit.ro Integer32 .1.3.6.1.4.1.248.11.11.1.1.20.1.3 |
hm2PSUUnitOutputTypeThe output type of the associated power supply slot module unit.ro Enumeration .1.3.6.1.4.1.248.11.11.1.1.20.1.4 |
hm2PSUUnitSystemBudgetThe system budget of the associated power supply slot module unit.ro Integer32 .1.3.6.1.4.1.248.11.11.1.1.20.1.5 |
hm2PSUUnitPoeBudgetThe Poe budget of the associated power supply slot module unit.ro Integer32 .1.3.6.1.4.1.248.11.11.1.1.20.1.6 |
hm2PSUUnitFanCountThe fan count of the associated power supply slot module unit.ro Integer32 .1.3.6.1.4.1.248.11.11.1.1.20.1.7 |
hm2PSUUnitVoltageRangeThe voltage range of the associated power supply slot module unit.ro Enumeration .1.3.6.1.4.1.248.11.11.1.1.20.1.8 |
hm2PSUUnitPowerInterruptionThe power interruption value of the associated power supply slot module unit.ro Enumeration .1.3.6.1.4.1.248.11.11.1.1.20.1.9 |
More MIBs from Hirschmann
Browse all HirschmannMIBs →SNMP MIB module
HM2-PLATFORM-SWITCHING-MIB provides programmatic access to Layer 2 switching parameters and operational statistics for Hirschmann (Belden) Private Platform2 network switches. This module enables the monitoring of standard bridging metrics, including MAC address table entries, port state transitions, spanning tree protocol (STP) topology changes, and interface error counters.
The HM2-PLATFORM-ROUTING-MIB provides management interfaces for Hirschmann Platform2 Layer 3 switches to monitor and configure dynamic routing protocols, including BGP, OSPF, and IS-IS, alongside static route tables and interface routing states.
The HIRSCHMANN-MMP4-BASICL2-MIB module provides SNMP management definitions for monitoring Layer 2 switching functions, including port status, MAC address tables, and VLAN configurations, on Hirschmann (Belden) Platform4 series network devices.
The HM2-DIAGNOSTIC-MIB facilitates the monitoring of internal hardware health and fault conditions on Hirschmann (Belden) network switches, specifically exposing diagnostic data such as temperature sensors, voltage levels, fan status, and power supply integrity via SNMP.
HM2-DEVMGMT-MIB facilitates the monitoring and management of Hirschmann (Belden) network devices by exposing standard system-level metrics such as device status, interface states, and hardware health parameters via SNMP. This module enables centralized administration of device configuration, fault detection, and performance data collection for industrial Ethernet infrastructure.