Home/Catalog/FOUNDRY-SN-NOTIFICATION-MIB

FOUNDRY-SN-NOTIFICATION-MIB

AI MIB Summary

The FOUNDRY-SN-NOTIFICATION-MIB defines proprietary SNMP trap definitions for Brocade (Foundry) router and switch platforms to alert management systems on specific hardware faults, link state transitions, and system events. It enables network monitoring solutions to parse vendor-specific asynchronous notifications rather than polling standard OIDs for real-time fault detection.

This MIB module describes proprietery SNMP Trap information of Brocade Communications' router/switch product. Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment.
Main OID:
snTraps.1.3.6.1.4.1.1991.0
245
Objects
Active
Status
12
Dependencies

Imported Objects

Objects

245 total
Object Name
snTrapsThis MIB module describes proprietery SNMP Trap information of Brocade Communications' router/switch product. Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions. This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment.
MODULE-IDENTITY
.1.3.6.1.4.1.1991.0
snTrapChasPwrSupplyThe SNMP trap that is generated when a power supply fails to operate normally. The value is a packed bit string; the 2 power supplies status are encoded into 4 bits (a nibble). The following shows the meaning of each bit: (bit 0 is the least significant bit). bit position meaning 4-31 reserved 3 Power Supply 2 DC (0=bad, 1=good). 2 Power Supply 1 DC (0=bad, 1=good). 1 Power Supply 2 present status (0=present, 1=not-present). 0 Power Supply 1 present status (0=present, 1=not-present).
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1
snTrapLockedAddressViolationThe SNMP trap that is generated when more source MAC addresses are received from a port than the maximum number of addresses configured to that port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.2
snTrapOspfIfStateChangeAn ospfIfStateChange trap signifies that there has been a change in the state of a non-virtual OSPF interface. This trap should be generated when the interface state regresses (e.g., goes from Dr to Down) or progresses to a terminal state (i.e., Point-to-Point, DR Other, Dr, or Backup).
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.3
snTrapOspfVirtIfStateChangeAn ospfIfStateChange trap signifies that there has been a change in the state of an OSPF vir- tual interface. This trap should be generated when the inter- face state regresses (e.g., goes from Point- to-Point to Down) or progresses to a terminal state (i.e., Point-to-Point).
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.4
snOspfNbrStateChangeAn ospfNbrStateChange trap signifies that there has been a change in the state of a non- virtual OSPF neighbor. This trap should be generated when the neighbor state regresses (e.g., goes from Attempt or Full to 1-Way or Down) or progresses to a terminal state (e.g., 2-Way or Full). When an neighbor transitions from or to Full on non-broadcast multi-access and broadcast networks, the trap should be gen- erated by the designated router. A designated router transitioning to Down will be noted by ospfIfStateChange.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.5
snOspfVirtNbrStateChangeAn ospfIfStateChange trap signifies that there has been a change in the state of an OSPF vir- tual neighbor. This trap should be generated when the neighbor state regresses (e.g., goes from Attempt or Full to 1-Way or Down) or progresses to a terminal state (e.g., Full).
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.6
snOspfIfConfigErrorAn ospfIfConfigError trap signifies that a packet has been received on a non-virtual in- terface from a router whose configuration parameters conflict with this router's confi- guration parameters. Note that the event op- tionMismatch should cause a trap only if it prevents an adjacency from forming.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.7
snOspfVirtIfConfigErrorAn ospfConfigError trap signifies that a pack- et has been received on a virtual interface from a router whose configuration parameters conflict with this router's configuration parameters. Note that the event optionMismatch should cause a trap only if it prevents an ad- jacency from forming.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.8
snOspfIfAuthFailureAn ospfIfAuthFailure trap signifies that a packet has been received on a non-virtual in- terface from a router whose authentication key or authentication type conflicts with this router's authentication key or authentication type.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.9
snOspfVirtIfAuthFailureAn ospfVirtIfAuthFailure trap signifies that a packet has been received on a virtual interface from a router whose authentication key or au- thentication type conflicts with this router's authentication key or authentication type.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.10
snOspfIfRxBadPacketAn ospfIfRxBadPacket trap signifies that an OSPF packet has been received on a non-virtual interface that cannot be parsed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.11
snOspfVirtIfRxBadPacketAn ospfRxBadPacket trap signifies that an OSPF packet has been received on a virtual interface that cannot be parsed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.12
snOspfTxRetransmitAn ospfTxRetransmit trap signifies than an OSPF packet has been retransmitted on a non- virtual interface. All packets that may be re- transmitted are associated with an LSDB entry. The LS type, LS ID, and Router ID are used to identify the LSDB entry.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.13
ospfVirtIfTxRetransmitAn ospfTxRetransmit trap signifies than an OSPF packet has been retransmitted on a virtual interface. All packets that may be retransmit- ted are associated with an LSDB entry. The LS type, LS ID, and Router ID are used to identify the LSDB entry.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.14
snOspfOriginateLsaAn ospfOriginateLsa trap signifies that a new LSA has been originated by this router. This trap should not be invoked for simple refreshes of LSAs (which happesn every 30 minutes), but instead will only be invoked when an LSA is (re)originated due to a topology change. Addi- tionally, this trap does not include LSAs that are being flushed because they have reached MaxAge.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.15
snOspfMaxAgeLsaAn ospfMaxAgeLsa trap signifies that one of the LSA in the router's link-state database has aged to MaxAge.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.16
snOspfLsdbOverflowAn ospfLsdbOverflow trap signifies that the number of LSAs in the router's link-state data- base has exceeded ospfExtLsdbLimit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.17
snOspfLsdbApproachingOverflowAn ospfLsdbApproachingOverflow trap signifies that the number of LSAs in the router's link- state database has exceeded ninety percent of ospfExtLsdbLimit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.18
snTrapL4MaxSessionLimitReachedThe SNMP trap that is generated when the maximum number of connections reached.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.19
snTrapL4TcpSynLimitReachedThe SNMP trap that is generated when the number of TCP SYN limits reached.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.20
snTrapL4RealServerUpThe SNMP trap that is generated when the load balancing real server is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.21
snTrapL4RealServerDownThe SNMP trap that is generated when the load balancing real server is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.22
snTrapL4RealServerPortUpThe SNMP trap that is generated when the load balancing real server TCP port is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.23
snTrapL4RealServerPortDownThe SNMP trap that is generated when the load balancing real server TCP port is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.24
snTrapL4RealServerMaxConnectionLimitReachedThe SNMP trap that is generated when the real server reaches maximum number of connections.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.25
snTrapL4BecomeStandbyThe SNMP trap that is generated when the server load balancing switch changes state from active to standby.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.26
snTrapL4BecomeActiveThe SNMP trap that is generated when the server load balancing switch changes state from standby to active.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.27
snTrapModuleInsertedThe SNMP trap that is generated when a module was inserted to the chassis during system running.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.28
snTrapModuleRemovedThe SNMP trap that is generated when a module was removed from the chassis during system running.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.29
snTrapChasPwrSupplyFailedThe SNMP trap that is generated when a power supply operational status changed from normal to failure.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.30
snTrapChasFanFailedThe SNMP trap that is generated when a fan fails to operate normally.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.31
snTrapLockedAddressViolation2The SNMP trap that is generated when more source MAC addresses are received from a port than the maximum number of addresses configured to that port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.32
snTrapFsrpIfStateChangeThe SNMP trap that is generated when a FSRP routing device changed state from active to standby or vice-versa.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.33
snTrapVrrpIfStateChangeThe SNMP trap that is generated when a VRRP routing device switched between states master, backup, intialized or uknown.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.34
snTrapMgmtModuleRedunStateChangeThe SNMP trap that is generated when the management module changes redundancy state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.35
snTrapTemperatureWarningThe SNMP trap that is generated when the actual temperature reading is above the warning temperature threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.36
snTrapAccessListDenyThe SNMP trap that is generated when a packet was denied by an access list.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.37
snTrapMacFilterDenyThe SNMP trap that is generated when a packet was denied by a MAC address filter.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.38
snTrapL4GslbRemoteUpThe SNMP trap that is generated when the connection to the remote SI is established.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.39
snTrapL4GslbRemoteDownThe SNMP trap that is generated when the connection to the remote SI is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.40
snTrapL4GslbRemoteControllerUpThe SNMP trap that is generated when the connection to the GSLB SI is established.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.41
snTrapL4GslbRemoteControllerDownThe SNMP trap that is generated when the connection to the GSLB SI is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.42
snTrapL4GslbHealthCheckIpUpThe SNMP trap that is generated when GSLB health check for an address transitions from down to active state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.43
snTrapL4GslbHealthCheckIpDownThe SNMP trap that is generated when GSLB health check for an address transitions from active to down state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.44
snTrapL4GslbHealthCheckIpPortUpThe SNMP trap that is generated when a given port for a health check address is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.45
snTrapL4GslbHealthCheckIpPortDownThe SNMP trap that is generated when a given port for a health check address is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.46
snTrapL4FirewallBecomeStandbyThe SNMP trap that is generated when the server load balancing switch Firewall changes state from active to standby.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.47
snTrapL4FirewallBecomeActiveThe SNMP trap that is generated when the server load balancing switch Firewall changes state from standby to active.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.48
snTrapL4FirewallPathUpThe SNMP trap that is generated when the server load balancing switch Firewall path is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.49
snTrapL4FirewallPathDownThe SNMP trap that is generated when the server load balancing switch Firewall path is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.50
snTrapIcmpLocalExceedBurstThe SNMP trap that is generated when incoming ICMP exceeds burst-MAX.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.51
snTrapIcmpTransitExceedBurstThe SNMP trap that is generated when transit ICMP exceeds burst-MAX.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.52
snTrapTcpLocalExceedBurstThe SNMP trap that is generated when incoming TCP SYN exceeds burst-MAX.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.53
snTrapTcpTransitExceedBurstThe SNMP trap that is generated when transit TCP exceeds burst-MAX.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.54
snTrapL4ContentVerificationThe SNMP trap that is generated when the HTTP match-list pattern is found.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.55
snTrapDuplicateIpDuplicate IP address detected.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.56
snTrapMplsProblemNOT IMPLEMENTED: MPLS Problem Detected.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.57
snTrapMplsExceptionNOT IMPLEMENTED: MPLS Exception Detected.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.58
snTrapMplsAuditNOT IMPLEMENTED: MPLS Audit Trap.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.59
snTrapMplsDeveloperNOT IMPLEMENTED: MPLS Developer Trap.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.60
snTrapNoBmFreeQueueThe SNMP trap that is generated when no free queue is available in buffer manager.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.61
snTrapSmcDmaDropThe SNMP trap that is generated when SMC DMA packet is dropped.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.62
snTrapSmcBpDropThe SNMP trap that is generated when SMC BackPlane packet is dropped.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.63
snTrapBmWriteSeqDropThe SNMP trap that is generated when BM write sequence packet is dropped.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.64
snTrapBgpPeerUpThe SNMP trap that is generated when the bgp peer is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.65
snTrapBgpPeerDownThe SNMP trap that is generated when the bgp peer is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.66
snTrapL4RealServerResponseTimeLowerLimitThe SNMP trap that is generated when the real server average response time exceeds lower threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.67
snTrapL4RealServerResponseTimeUpperLimitThe SNMP trap that is generated when the real server average response time exceeds upper threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.68
snTrapL4TcpAttackRateExceedMaxThe SNMP trap that is generated when the TCP attack rate exceeds configured maximum.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.69
snTrapL4TcpAttackRateExceedThresholdThe SNMP trap that is generated when the TCP attack rate exceeds 80% of configured maximum.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.70
snTrapL4ConnectionRateExceedMaxThe SNMP trap that is generated when the L4 connection rate exceeds configured maximum.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.71
snTrapL4ConnectionRateExceedThresholdThe SNMP trap that is generated when the L4 connection rate exceeds 80% of configured maximum
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.72
snTrapRunningConfigChangedThe SNMP trap that is generated when the running configuration was changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.73
snTrapStartupConfigChangedThe SNMP trap that is generated when the startup configuration was changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.74
snTrapUserLoginThe SNMP trap that is generated when user login.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.75
snTrapUserLogoutThe SNMP trap that is generated when user logout.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.76
snTrapPortSecurityViolationThe SNMP trap that is generated when insecure MAC addresses are received from a port with MAC security feature enabled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.77
snTrapPortSecurityShutdownThe SNMP trap that is generated when insecure MAC addresses are received from a port caused the port to shutdown.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.78
snTrapMrpStateChangeThe SNMP trap that is generated when a MRP switching and routing device changed state to disabled, blocking, preforwarding, forwarding, uknown.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.79
snTrapMrpCamErrorThe SNMP trap that is generated when a MRP Cam Error occurs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.80
snTrapChasPwrSupplyOKThe SNMP trap that is generated when a power supply operational status changed from failure to normal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.81
snTrapVrrpeIfStateChangeThe SNMP trap that is generated when a VRRPE routing device switched between states master, backup, intialized or uknown.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.82
snTrapVsrpIfStateChangeThe SNMP trap that is generated when a VSRP switching and routing device switched between states master, backup, intialized or uknown.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.83
snTrapSrcIpAddressViolationThe SNMP trap that is generated when a rogue device spoofs source IP address for denial of service attack.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.84
snTrapMacAuthEnableThe SNMP trap that is generated when MAC-Authentication is enabled on an interface.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.85
snTrapMacAuthDisableThe SNMP trap that is generated when MAC-Authentication is disabled on an interface.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.86
snTrapMacAuthMACAcceptedThe SNMP trap that is generated when MAC-Authentication is successful on an interface.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.87
snTrapMacAuthMACRejectedThe SNMP trap that is generated when MAC-Authentication is failed on an interface.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.88
snTrapMacAuthPortDisabledThe SNMP trap that is generated when an interface is disabled due to MAC-Authentication detecting a DOS attack on that interface.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.89
snTrapClientLoginRejectThe SNMP trap that is generated when a login attempt by a telnet or SSH client fails.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.110
snTrapLocalUserConfigChangeThe SNMP trap that is generated when a local user configuration is changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.111
snTrapVlanConfigChangeThe SNMP trap that is generated when a vlan configuration is changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.112
snTrapAclConfigChangeThe SNMP trap that is generated when a ACL configuration is changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.113
snTrapMacFilterConfigChangeThe SNMP trap that is generated when a MAC Filter configuration is changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.114
snTrapSNMPConfigChangeThe SNMP trap that is generated when a SNMP configuration is changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.115
snTrapSyslogConfigChangeThe SNMP trap that is generated when syslog is enabled/disabled globally, or when a syslog server is added/deleted.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.116
snTrapPasswordConfigChangeThe SNMP trap that is generated when enable or line password is changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.117
snTrapServerStatusChangeThe SNMP trap that is generated when a server is disabled or enabled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.118
snTrapL4RealServerPortMaxConnectionLimitReachedThe SNMP trap that is generated when the real server's port reaches maximum number of connections.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.119
snTrapL4LinkDownThe SNMP trap that is generated when the ISP link goes down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.120
snTrapL4LinkUpThe SNMP trap that is generated when the ISP link goes up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.121
snTrapPortPriorityChangeThe SNMP trap that is generated when the priority of a port is changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.122
snTrapAutoPortDisableTriggerThe SNMP trap that is generated when automatic port disable was triggered.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.123
snTrapAutoPortDisableReleaseThe SNMP trap that is generated when automatic port disable was released.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.124
snTrapPnPStatusChangeThe SNMP trap that is generated when plug-and-play status change.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.125
snTrapWirelessIsrpPeerStateChangeThe SNMP trap that is generated when ISRP Peer changes state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.126
snTrapWirelessStationStateChangeThe SNMP trap that is generated when a wireless station's state changes.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.127
snTrapWirelessStationRoamingEventTriggeredThe SNMP trap that is generated when we received a MOVE request from the AP
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.128
snTrapWirelessSappStateChangeThe SNMP trap that is generated when SAPP between an AP and a FIPS changes state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.129
snTrapExternalPowerConnectionStatusThe SNMP trap that is generated when the external power supply connecting or disconnecting to a power over ethernet module.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.130
snTrapDot1xSecurityViolationThe SNMP trap that is generated when a malicious mac address was detected.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.131
snTrapDot1xPortLinkChangeThe SNMP trap that is generated when software port link status has changed to up or down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.132
snTrapDot1xPortControlChangeThe SNMP trap that is generated when software port control status has changed to authorize or unauthorize.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.133
snTrapDot1xVlanIdChangeThe SNMP trap that is generated when VLAN ID of a port has changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.134
snTrapDot1xFilterSetupFailureThe SNMP trap that is generated when software failed to setup a filter to a mac address of a port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.135
snTrapDot1xErrorThe SNMP trap that is generated when software detected system error.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.136
snTrapPortConfigChangeThe SNMP trap that is generated when a port configuration is changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.137
snTrapMacAuthVlanIdChangeThe SNMP trap that is generated when VLAN ID of a port has changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.138
snTrapWebAuthEnabledThe SNMP trap that is generated when web authentication is enabled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.139
snTrapWebAuthDisabledThe SNMP trap that is generated when web authentication is disabled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.140
snTrapIpConfigChangeThe SNMP trap that is generated when IP system address changes.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.141
snTrapIpv6ConfigChangeThe SNMP trap that is generated when IPv6 system address changes.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.142
snTrapMacAuthRadiusTimeoutThe SNMP trap that is generated when a request from Mac-Auth to RADIUS has not been answered within the retry and time limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.143
snTrapDot1xRadiusTimeoutThe SNMP trap that is generated when a request from 802.1x to RADIUS has not been answered within the retry and time limit.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.144
snTrapUDLDLinkDownThe SNMP trap that is generated when UDLD port link status has changed to down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.145
snTrapUDLDLinkUpThe SNMP trap that is generated when UDLD port link status has changed to up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.146
snTrapMacBasedVlanEnabledThe SNMP trap that is generated when MAC based VLAN is enabled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.147
snTrapMacBasedVlanDisabledThe SNMP trap that is generated when MAC based VLAN is disabled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.148
snTrapChasFanNormalThe SNMP trap that is generated when a fan operational status changed from failure to normal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.149
snTrapStpRootGuardDetectThe SNMP trap that is generated when VLAN's Root-Guarded port received superior BPDU.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.150
snTrapStpRootGuardExpireThe SNMP trap that is generated when VLAN's ports's Root-Guard expire.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.151
snTrapStpBPDUGuardDetectThe SNMP trap that is generated when VLAN's BPDU-guarded port received BPDU .
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.152
snTrapMstpBPDUGuardDetectThe SNMP trap that is generated when BPDU-guarded port received BPDU .
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.153
snTrapErrorDisableActionThe SNMP trap that is generated when Interface error-disable is hit or recovery times out .
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.154
snTrapLACPLinkStateChangeThe SNMP trap that is generated when LACP port changes its state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.155
snTrapOpticalMonitoringNotFoundryOpticsThe SNMP trap that is generated if optical monitoring is enabled but optics vendor is not Foundry Networks.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.156
snTrapOpticalMonitoringFoundryOpticsNotCapableThe SNMP trap that is generated if optical monitoring is enabled but the Foundry optic is not capable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.157
snTrapStaticMulticastMacConfigAddThe SNMP trap that is generated if a new entry is added to static multicast mac configuration table. Format 1: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is added to portnumber <port> on VLAN <id> Format 2: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is added to portmask <0xXXXXXXXX-XXXXXXXX> on VLAN <id>
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.158
snTrapStaticMulticastMacConfigRemoveThe SNMP trap that is generated if an entry is removed from static multicast mac configuration table . Format 1: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is deleted from portnumber <port> on VLAN <id> Format 2: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is deleted from portmask <0xXXXXXXXX-XXXXXXXX> on VLAN <id>
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.159
snTrapSTPBPDUGuardExpireThe SNMP notification that is generated when a port is re-enabled after being disabled due to BPDU Guard Violation. Format: STP: BPDU Guard re-enabled on VLAN <id> port <slot>/<port>
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.160
snTrapPortLoopDetectionThe SNMP notification is generated when a port loop is detected. Format: LOOP DETECTION: VLAN <id>, port <slot>/<port> detect, putting into err-disable state
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.161
snTrapNoFreeTcamEntryThe SNMP trap that is generated when system is running out of TCAM spaces allocated for routing entries.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.162
snTrapStackingMasterElectedThe SNMP trap that is generated when a unit is elected as Master unit for the stacking system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.163
snTrapStackingUnitAddedThe SNMP trap that is generated when a unit has been added to the stacking system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.164
snTrapStackingUnitDeletedThe SNMP trap that is generated when a unit has been deleted from the stacking system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.165
snTrapStackingChasPwrSupplyOKThe SNMP trap that is generated when a power supply operational status changed from failure to normal for a stacking system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.166
snTrapStackingChasPwrSupplyFailedThe SNMP trap that is generated when a power supply operational status changed from normal to failure for a stacking system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.167
snTrapStackingChasFanNormalThe SNMP trap that is generated when a fan operational status changed from failure to normal for a stacking system
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.168
snTrapStackingChasFanFailedThe SNMP trap that is generated when a fan fails to operate normally for a stacking system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.169
snTrapStackingManagementMACChangedThe SNMP trap that is generated when the managemnet MAC address of a stacking system has been changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.170
snTrapStackingTemperatureWarningThe SNMP trap that is generated when the actual temperature reading is above the warning temperature threshold for a stack sytem.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.171
snTrapIfIndexAssignmentChangedThe SNMP trap that is generated when the Interface Index (IfIndex) assignment for the physical interfaces was changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.172
snTrapPBRConfigChangedThe SNMP trap that is generated when a Policy Based Routing (PBR) routemap is bound or unbound either globally or to an interface.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.173
snTrapChasPwrSupplyRPSAddThe SNMP trap that is generated when an External Redundant Power Supply (RPS2-EIF) is added to the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.174
snTrapChasPwrSupplyRPSRemoveThe SNMP trap that is generated when an External Redundant Power Supply (RPS2-EIF) is removed from the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.175
snTrapModuleStatusChangeThe SNMP notification that is generated when a module's operational state changes. The management entity receiving the notification can identify the module and the event by referencing snChasUnitIndex, snAgentBrdIndex, snAgentBrdModuleStatus. In case of a module-down event, the varbind snAgGblTrapMessage is a text string that describes the cause. In case of module-up event, snAgGblTrapMessage is a null string.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.176
snTrapChasHighSpeedFansNeededThe SNMP trap that is generated when chassis doesn't have high speed fans for specific modules
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.177
snTrapSysmaxRevertedThe SNMP trap that is generated when the revertible sysmax elements are reverted during the card bringup if they can not be accomodated in the available memory.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.178
snTrapSysmaxLeftLowMemThe SNMP trap that is generated when its found during bootup that the configured sysmax set shall leave less than 10% available memory free.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.179
snTrapSysMemoryLowThresholdThe SNMP trap that is generated when the available dynamic memory in a card is below 5% of the installed physical memory.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.180
snTrapSysMemoryOutThresholdThe SNMP trap that is generated when the dynamic memory fails to be allocated in a system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.181
snTrapLinkOAMLinkDownThe SNMP trap that is generated when Link-OAM port link status has changed to down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.182
snTrapLinkOAMLinkUpThe SNMP trap that is generated when Link-OAM port link status has changed to up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.183
snTrapI2CAccessLogThe SNMP trap that is generated to provide information about state of the management module's I2C accesses.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.184
snTrapLinkOAMLoopbackEnteredThe SNMP trap that is generated when Link-OAM port has entered loopback mode. The link is not useful for data transfer any more.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.185
snTrapLinkOAMLoopbackClearedThe SNMP trap that is generated when Link-OAM port has entered loopback mode. The link is not useful for data transfer any more.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.186
snTrapLicenseAddedThe SNMP trap that is generated when a new license is added to the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.187
snTrapLicenseRemovedThe SNMP trap that is generated when an existing license is removed from the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.188
snTrapLicenseExpiresThe SNMP trap that is generated when a trial license is about to expire. This trap is generated daily for last 3 days and every 2 hours on the last day of expire.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.189
snTrapLicenseExpiredThe SNMP trap that is generated when a trial license has expired.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.190
snTrapUDLDCrcFailureDetectedThe SNMP trap that is generated when UDLD detects CRC failures on PDUs received on a port
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.191
snTrapDot1agCfmRemoteMEPAgeOutThe SNMP trap that is generated when 802.1ag Remote MEP ages out.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.192
snTrapDot1agCfmRemoteMEPUpThe SNMP trap that is generated when 802.1ag Remote MEP is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.193
snTrapDot1agCfmDomainCrossConnectionThe SNMP trap that is generated when 802.1ag domain gets cross-connected.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.194
snTrapDot1agCfmDuplicateMEPIdThe SNMP trap that is generated when 802.1ag Remote MEP reports a duplicate MEP Id that conflicts with local MEP Id.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.195
snTrapStackingStandbyElectedThe SNMP trap that is generated when a unit is elected as Standby unit for the stacking system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.196
snTrapMacMoveThresholdRateThe SNMP notification is generated when MAC movement exceeding the certain threshold for a sampling interval is detected. Format: Mac-Move threshold-rate: MAC address <mac> moved from interface <port-id> to interface <port-id> for vlan <vlan-id>, <move-count> times exceeding the threshold rate <threshold-rate> for a sampling interval <interval> seconds
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.197
snTrapMacMoveIntervalHistoryThe SNMP notification is generated every user configured interval, summarizing the moves in the interval . Format: Mac-Move Interval-History: <#macs> macs moved in last <interval> seconds. Total number of mac moves in the interval is <#moves>
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.198
snTrapStackingMixedModeChangedThe SNMP trap that is generated when a stacking system mode is changed. Format: The stacking system is changed to Mixed Stacking mode
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.199
snTrapSysMonErrorDetectThe SNMP notification is generated when SYSMON detects internal error.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.200
snTrapMacNotificationThe SNMP notification is generated when MAC event(s) is(are) detected. Format: MAC-Event:MAC:<mac>-VLAN:<vlan-id>-PORT:<port-id>-ACT:<action>::MAC:<mac>-VLAN:<vlan-id>-PORT:<port-id>-ACT:<action>:: ... ...MAC:<mac>-VLAN:<vlan-id>-PORT:<port-id>-ACT:<action>:: where action: 1-MAC addition; 2-MAC deletion; 3-remove all MACs; 4-remove MAC from a port; 5-remove MAC from a VLAN; 6-remove MAC from a VLAN on a port
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.201
snTrapMacEventBufferFullThe SNMP notification is generated when MAC event buffer full is detected. Format: MAC-Event: The Buffer is full, FDB table walk is required
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.202
snTrapStpDesignatedGuardDetectThe SNMP trap that is generated when VLAN's ports's Designated-Guard detect.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.203
snTrapStpDesignatedGuardDisableThe SNMP trap that is generated when VLAN's ports's Designated-Guard disable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.204
snTrapLicenseNNLLTrialNotifyThe SNMP trap that is generated when a non-node locked licensed feature is enabled with no a non-node locked license installed. Format: Stack <stack_id>: Use of the <feature_name> feature requires a license to be purchased and installed within <day> days.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.205
snTrapLicenseNNLLTrialExpiryThe SNMP trap that is generated when a non-node locked licensed feature is enabled after 30-44 days with no a non-node locked license installed. This message will be displayed 3 times day 30, day 37, day 44. Format: Stack <stack_id>: The <feature_name> feature has been activated for <day> days. To ensure compliance, please purchase and install a license as soon as possible
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.206
snTrapLicenseNNLLNonCompliantThe SNMP trap that is generated when a non-node locked licensed feature is enabled after 45+ days whit no a non-node locked license installed. Or deletion of an installed license if any of the associated features are still enabled. This message will be displayed daily. Format: Stack <stack_id>: THIS UNIT IS NOT COMPLIANT. A license for <feature_name> feature must be purchased and installed or the feature <feature_name> must be deactivated to become compliant with the terms and conditions of use
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.207
snTrapLicenseNNLLDeleteThe SNMP trap that is generated when a non-node locked licensed feature is enabled after a non-node locked license is deleted. Format: Stack <stack_id>: The <license_name> license has been deleted on this unit and is available for redeployment on another unit in accordance with the terms and conditions of use. All features associated to this license must be disabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.208
snTrapStackingShowStackConnectThe SNMP trap that is generated when the background diagnosis detects the connection errors to notify the user to check the connections in a stacking system Format: Background diagnosis detects connection errors. Please use show stack conn to view detailed connections
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.209
snTrapStackingStandByChangedStandaloneThe SNMP trap that is generated when a unit is changed from Standby to Stand alone when the active unit is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.210
snTrapChasFanOKThe SNMP trap that is generated when a fan operational status changed from failure to normal or change in the fan speed due to temperature variations downwards.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1000
snTrapTemperatureOKThe SNMP trap that is generated when the actual temperature reading is below the warning temperature threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1001
snTrapCAMOverflowThe SNMP trap that is generated when any CAM partition becomes full.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1002
snTrapOpticalMonitoringWarningThe SNMP trap that is generated if there is a warning during optical monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1003
snTrapOpticalMonitoringAlarmThe SNMP trap that is generated if there is an alarm during optical monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1004
snTrapOpticalMonitoringErrorThe SNMP trap that is generated if there is an error during optical monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1005
snTrapPosMonitoringWarningThe SNMP trap that is generated if there is a warning during POS alarm monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1006
snTrapPosMonitoringAlarmThe SNMP trap that is generated if there is an alarm up/down during POS alarm monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1007
snTrapPosMonitoringErrorThe SNMP trap that is generated if there is an error during POS alarm monitoring. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second optional varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1008
snTrapXfpSfpIncompatibleOpticsThe SNMP trap that is generated if optics is incompatible with port configuration.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1009
snTrapTMLoggingStartThe SNMP trap that is generated if TM logging is started by an event trigger.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1015
snTrapTMLoggingStopThe SNMP trap that is generated if TM logging stopped due to storage full.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1016
snTrapTMLoggingRestartThe SNMP trap that is generated if TM logging restarted after user clearing the log.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1017
snTrapXfpSfpNotFoundryOpticsThe SNMP trap that is generated if optics vendor is not Foundry Networks.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1018
snTrapTMRecoverySlotResetThe SNMP trap that is generated when TM recovery slot reset is triggered.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1019
snTrapTMEgressDataErrorThe SNMP trap that is generated when system detects egress data errors on Traffic Manager. For e.g. Fabric Monitoring : TM Egress data errors detected on LP <num>/TM <num>
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1020
snTrapSFMLoggingRestartThe SNMP trap that is generated if SFM logging restarted after user clearing the log.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1021
snTrapSFMLinkDownThe SNMP trap that is generated when a link from LP Traffic Manager to SFM Fabric Element is down. For eg. Fabric Monitoring Link Down : SFM <num>/FE <num>/Link <num>, LP <num>/TM <num>
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1100
snTrapSFMLinkUpThe SNMP trap that is generated when a link from LP Traffic Manager to SFM Fabric Element is up. For eg. Fabric Monitoring Link Up : SFM <num>/FE <num>/Link <num>, LP <num>/TM <num>
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1101
snTrapSFMAccessErrorThe SNMP trap that is generated when system fails to access a SFM Fabric Element. For e.g. Fabric Monitoring : Device access failure in SFM <num>/FE <num>
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1102
snTrapSFMStatusChangeThe SNMP notification that is generated when there is a change in the operational state of the Switch Fabric Module (SFM). For example, System: Health Monitoring: SFM <num> powered off due to failure detection
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1103
snTrapLPFabricStatusChangeHealth Monitoring: LP Fabric status change.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1104
snTrapModuleNPLockupIndicationThe SNMP notification that is generated for the module's NP health monitoring to indicate that a lockup and recovery have occurred. Expressed in number of times in the past 1 hour
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1105
snTrapModuleNPLockupThresholdExceededThe SNMP notification that is generated for the module's NP health monitoring when the threshold for lockup and recovery of any NP within the module have been reached. The threshold value is 5 times in the past 1 hour.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1106
snTrapSFMAutoTuneStartThe SNMP trap that is generated when Auto tuning starts on the fabric side
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1107
snTrapSFMAutoTuneFailsThe SNMP trap that is generated when Auto tuning fails on the fabric side
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1108
snTrapSFMAutoTuneCompleteThe SNMP trap that is generated when Auto tuning completes on the fabric side
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1109
snTrapTMAutoTuneStartThe SNMP trap that is generated when Auto tuning starts on the TM side
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1110
snTrapTMAutoTuneFailsThe SNMP trap that is generated when Auto tuning fails on the TM side
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1111
snTrapTMAutoTuneCompleteThe SNMP trap that is generated when Auto tuning completes on the TM side
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1112
snTrapNPILKNCRCErrorThe SNMP trap that is generated when packet drops are observed in 2x100G ports because of Interlaken CRC errors
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1113
snTrapARPMACMovementThe SNMP trap that is generated when the MAC address associated with a host IP is changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1114
snTrapChassisFanSpeedLowThe SNMP trap that is generated when all chassis fans change to low speed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1200
snTrapChassisFanSpeedMediumThe SNMP trap that is generated when all chassis fans change to medium speed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1201
snTrapChassisFanSpeedMedHighThe SNMP trap that is generated when all chassis fans change to medium high speed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1202
snTrapChassisFanSpeedHighThe SNMP trap that is generated when all chassis fans change to high speed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1203
snTrapFIPSModeEnableThe SNMP trap that is generated when FIPS mode is enabled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1207
snTrapFIPSModeDisableThe SNMP trap that is generated when FIPS mode is disabled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1208
snTrapFIPSHostZeroizedThe SNMP trap that is generated when host keys are zeroized in FIPS mode
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1209
snTrapFIPSSharedSecretZeroizedThe SNMP trap that is generated when shared secret are zeroized in FIPS mode
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1210
snTrapFIPSPOSTStatusThe SNMP trap that is generated after POST.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1211
snTrapFIPSCryptoModuleFailureThe SNMP trap that is generated on cryptographic module failure.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1212
snTrapLicense2PortNotSupportedThe SNMP trap that is generated when a 2 port license cannot be applied due to hardware limitation.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1213
snTrapOpticalMonitoringOKThe SNMP trap that is generated when an interface transitions from an error to normal state because the alarms/warnings are below the threshold. snTrapOpticalMonitoringError would have been earlier generated when the interface transitioned to the error state. The first varbind, snAgGblTrapMessage, will have a detailed message on the cause of event. The second varbind, ifIndex, points to the affected interface originating this event. If an event does not have associated port, or has multiple associated ports, then ifIndex will have maximum value 0x7ffffff.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1214
snTrapSFMAccessOKThe SNMP trap that is generated when system can successfully access an SFM Fabric Element. snTrapSFMAccessError would have been generated when the system failed to access the FE. For e.g. Fabric Monitoring : Device SFM <num>/FE <num> is OK to access.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1215
snTrapUpgradeSingleCmdStartThe SNMP trap that is generated when the single-command package upgrade has started. This happens after a successful download and validation of manifest file and before the first image download takes place.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1216
snTrapUpgradeSingleCmdDoneThe SNMP trap that is generated when the single-command package upgrade completed, or partially completed. The table brcdSwPackageLoadResultTable lists the result of the upgrade.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1217
snTrapAutoUpgradeStartThe SNMP trap that is generated when an auto-upgrade on a line card has started.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1218
snTrapAutoUpgradeDoneThe SNMP trap that is generated when the auto-upgrade of interface module completed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1219
snTrapTcamParityErrorThe SNMP trap that is generated when the TCAM parity errors are detected on LP.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1220
snTrapLPResetOnTcamErrorThe SNMP trap that is generated when the LP reset due to TCAM parity errors crossing the threshold or TCAM integrity check failure.
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1221
snTrapSTPRootGuardViolationThe SNMP trap that is generated when STP Root Guard Violation occurs on a port. Format: STP: Root-protect port <slot>/<port>, VLAN <id> inconsistent (Received superior BPDU)
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1230
snTrapRSTPRootGuardViolationThe SNMP trap that is generated when STP Root Guard Violation occurs on a port. Format: RSTP: Root-protect port <slot>/<port>, VLAN <id> inconsistent (Received superior BPDU)
NOTIFICATION-TYPE
.1.3.6.1.4.1.1991.0.1231
FOUNDRY-SN-NOTIFICATION-MIB - SNMP MIB Reference | MIBs Explorer