FOUNDRY-SN-NOTIFICATION-MIB
AI MIB Summary
The FOUNDRY-SN-NOTIFICATION-MIB defines proprietary SNMP trap definitions for Brocade (Foundry) router and switch platforms to alert management systems on specific hardware faults, link state transitions, and system events. It enables network monitoring solutions to parse vendor-specific asynchronous notifications rather than polling standard OIDs for real-time fault detection.
This MIB module describes proprietery SNMP Trap information of Brocade Communications' router/switch product.
Copyright 1996-2010 Brocade Communications Systems, Inc. All rights reserved. This Brocade Communications Systems SNMP Management Information Base Specification embodies Brocade Communications Systems' confidential and proprietary intellectual property. Brocade Communications Systems retains all title and ownership in the Specification, including any revisions.
This Specification is supplied AS IS, and Brocade Communications Systems makes no warranty, either express or implied, as to the use, operation, condition, or performance of the specification, and any unintended consequence it may on the user environment.
Main OID:
snTraps.1.3.6.1.4.1.1991.0
245
Objects
Active
Status
12
Dependencies
Imported Objects
Objects
245 total| Object Name |
|---|
snTrapsThis MIB module describes proprietery SNMP Trap information
of Brocade Communications' router/switch product.
Copyright 1996-2010 Brocade Communications Systems, Inc.
All rights reserved.
This Brocade Communications Systems SNMP Management Information Base Specification
embodies Brocade Communications Systems' confidential and proprietary
intellectual property. Brocade Communications Systems retains all
title and ownership in the Specification, including any revisions.
This Specification is supplied AS IS, and Brocade Communications Systems makes
no warranty, either express or implied, as to the use,
operation, condition, or performance of the specification, and any unintended
consequence it may on the user environment. MODULE-IDENTITY .1.3.6.1.4.1.1991.0 |
snTrapChasPwrSupplyThe SNMP trap that is generated when a power supply fails
to operate normally. The value is a packed bit string;
the 2 power supplies status are encoded into 4 bits
(a nibble).
The following shows the meaning of each bit:
(bit 0 is the least significant bit).
bit position meaning
4-31 reserved
3 Power Supply 2 DC (0=bad, 1=good).
2 Power Supply 1 DC (0=bad, 1=good).
1 Power Supply 2 present status (0=present, 1=not-present).
0 Power Supply 1 present status (0=present, 1=not-present). NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1 |
snTrapLockedAddressViolationThe SNMP trap that is generated when more source MAC addresses
are received from a port than the maximum number of addresses
configured to that port. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.2 |
snTrapOspfIfStateChangeAn ospfIfStateChange trap signifies that there
has been a change in the state of a non-virtual
OSPF interface. This trap should be generated
when the interface state regresses (e.g., goes
from Dr to Down) or progresses to a terminal
state (i.e., Point-to-Point, DR Other, Dr, or
Backup). NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.3 |
snTrapOspfVirtIfStateChangeAn ospfIfStateChange trap signifies that there
has been a change in the state of an OSPF vir-
tual interface.
This trap should be generated when the inter-
face state regresses (e.g., goes from Point-
to-Point to Down) or progresses to a terminal
state (i.e., Point-to-Point). NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.4 |
snOspfNbrStateChangeAn ospfNbrStateChange trap signifies that
there has been a change in the state of a non-
virtual OSPF neighbor. This trap should be
generated when the neighbor state regresses
(e.g., goes from Attempt or Full to 1-Way or
Down) or progresses to a terminal state (e.g.,
2-Way or Full). When an neighbor transitions
from or to Full on non-broadcast multi-access
and broadcast networks, the trap should be gen-
erated by the designated router. A designated
router transitioning to Down will be noted by
ospfIfStateChange. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.5 |
snOspfVirtNbrStateChangeAn ospfIfStateChange trap signifies that there
has been a change in the state of an OSPF vir-
tual neighbor. This trap should be generated
when the neighbor state regresses (e.g., goes
from Attempt or Full to 1-Way or Down) or
progresses to a terminal state (e.g., Full). NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.6 |
snOspfIfConfigErrorAn ospfIfConfigError trap signifies that a
packet has been received on a non-virtual in-
terface from a router whose configuration
parameters conflict with this router's confi-
guration parameters. Note that the event op-
tionMismatch should cause a trap only if it
prevents an adjacency from forming. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.7 |
snOspfVirtIfConfigErrorAn ospfConfigError trap signifies that a pack-
et has been received on a virtual interface
from a router whose configuration parameters
conflict with this router's configuration
parameters. Note that the event optionMismatch
should cause a trap only if it prevents an ad-
jacency from forming. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.8 |
snOspfIfAuthFailureAn ospfIfAuthFailure trap signifies that a
packet has been received on a non-virtual in-
terface from a router whose authentication key
or authentication type conflicts with this
router's authentication key or authentication
type. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.9 |
snOspfVirtIfAuthFailureAn ospfVirtIfAuthFailure trap signifies that a
packet has been received on a virtual interface
from a router whose authentication key or au-
thentication type conflicts with this router's
authentication key or authentication type. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.10 |
snOspfIfRxBadPacketAn ospfIfRxBadPacket trap signifies that an
OSPF packet has been received on a non-virtual
interface that cannot be parsed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.11 |
snOspfVirtIfRxBadPacketAn ospfRxBadPacket trap signifies that an OSPF
packet has been received on a virtual interface
that cannot be parsed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.12 |
snOspfTxRetransmitAn ospfTxRetransmit trap signifies than an
OSPF packet has been retransmitted on a non-
virtual interface. All packets that may be re-
transmitted are associated with an LSDB entry.
The LS type, LS ID, and Router ID are used to
identify the LSDB entry. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.13 |
ospfVirtIfTxRetransmitAn ospfTxRetransmit trap signifies than an
OSPF packet has been retransmitted on a virtual
interface. All packets that may be retransmit-
ted are associated with an LSDB entry. The LS
type, LS ID, and Router ID are used to identify
the LSDB entry. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.14 |
snOspfOriginateLsaAn ospfOriginateLsa trap signifies that a new
LSA has been originated by this router. This
trap should not be invoked for simple refreshes
of LSAs (which happesn every 30 minutes), but
instead will only be invoked when an LSA is
(re)originated due to a topology change. Addi-
tionally, this trap does not include LSAs that
are being flushed because they have reached
MaxAge. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.15 |
snOspfMaxAgeLsaAn ospfMaxAgeLsa trap signifies that one of
the LSA in the router's link-state database has
aged to MaxAge. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.16 |
snOspfLsdbOverflowAn ospfLsdbOverflow trap signifies that the
number of LSAs in the router's link-state data-
base has exceeded ospfExtLsdbLimit. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.17 |
snOspfLsdbApproachingOverflowAn ospfLsdbApproachingOverflow trap signifies
that the number of LSAs in the router's link-
state database has exceeded ninety percent of
ospfExtLsdbLimit. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.18 |
snTrapL4MaxSessionLimitReachedThe SNMP trap that is generated when the maximum number
of connections reached. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.19 |
snTrapL4TcpSynLimitReachedThe SNMP trap that is generated when the number of TCP
SYN limits reached. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.20 |
snTrapL4RealServerUpThe SNMP trap that is generated when the load balancing
real server is up. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.21 |
snTrapL4RealServerDownThe SNMP trap that is generated when the load balancing
real server is down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.22 |
snTrapL4RealServerPortUpThe SNMP trap that is generated when the load balancing
real server TCP port is up. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.23 |
snTrapL4RealServerPortDownThe SNMP trap that is generated when the load balancing
real server TCP port is down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.24 |
snTrapL4RealServerMaxConnectionLimitReachedThe SNMP trap that is generated when the real server reaches
maximum number of connections. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.25 |
snTrapL4BecomeStandbyThe SNMP trap that is generated when the server load
balancing switch changes state from active to standby. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.26 |
snTrapL4BecomeActiveThe SNMP trap that is generated when the server load
balancing switch changes state from standby to active. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.27 |
snTrapModuleInsertedThe SNMP trap that is generated when a module was inserted
to the chassis during system running. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.28 |
snTrapModuleRemovedThe SNMP trap that is generated when a module was removed
from the chassis during system running. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.29 |
snTrapChasPwrSupplyFailedThe SNMP trap that is generated when a power supply operational
status changed from normal to failure. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.30 |
snTrapChasFanFailedThe SNMP trap that is generated when a fan fails
to operate normally. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.31 |
snTrapLockedAddressViolation2The SNMP trap that is generated when more source MAC addresses
are received from a port than the maximum number of addresses
configured to that port. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.32 |
snTrapFsrpIfStateChangeThe SNMP trap that is generated when a FSRP routing device
changed state from active to standby or vice-versa. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.33 |
snTrapVrrpIfStateChangeThe SNMP trap that is generated when a VRRP routing device
switched between states master, backup, intialized or uknown. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.34 |
snTrapMgmtModuleRedunStateChangeThe SNMP trap that is generated when the management module
changes redundancy state. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.35 |
snTrapTemperatureWarningThe SNMP trap that is generated when the actual temperature
reading is above the warning temperature threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.36 |
snTrapAccessListDenyThe SNMP trap that is generated when a packet was denied
by an access list. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.37 |
snTrapMacFilterDenyThe SNMP trap that is generated when a packet was denied
by a MAC address filter. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.38 |
snTrapL4GslbRemoteUpThe SNMP trap that is generated when the connection to the remote SI is established. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.39 |
snTrapL4GslbRemoteDownThe SNMP trap that is generated when the connection to the remote SI is down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.40 |
snTrapL4GslbRemoteControllerUpThe SNMP trap that is generated when the connection to the GSLB SI is established. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.41 |
snTrapL4GslbRemoteControllerDownThe SNMP trap that is generated when the connection to the GSLB SI is down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.42 |
snTrapL4GslbHealthCheckIpUpThe SNMP trap that is generated when GSLB health check for an address transitions
from down to active state. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.43 |
snTrapL4GslbHealthCheckIpDownThe SNMP trap that is generated when GSLB health check for an address transitions
from active to down state. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.44 |
snTrapL4GslbHealthCheckIpPortUpThe SNMP trap that is generated when a given port for a health check address is up. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.45 |
snTrapL4GslbHealthCheckIpPortDownThe SNMP trap that is generated when a given port for a health check address is down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.46 |
snTrapL4FirewallBecomeStandbyThe SNMP trap that is generated when the server load
balancing switch Firewall changes state from active to standby. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.47 |
snTrapL4FirewallBecomeActiveThe SNMP trap that is generated when the server load
balancing switch Firewall changes state from standby to active. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.48 |
snTrapL4FirewallPathUpThe SNMP trap that is generated when the server load
balancing switch Firewall path is up. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.49 |
snTrapL4FirewallPathDownThe SNMP trap that is generated when the server load
balancing switch Firewall path is down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.50 |
snTrapIcmpLocalExceedBurstThe SNMP trap that is generated when incoming ICMP exceeds burst-MAX. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.51 |
snTrapIcmpTransitExceedBurstThe SNMP trap that is generated when transit ICMP exceeds burst-MAX. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.52 |
snTrapTcpLocalExceedBurstThe SNMP trap that is generated when incoming TCP SYN exceeds burst-MAX. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.53 |
snTrapTcpTransitExceedBurstThe SNMP trap that is generated when transit TCP exceeds burst-MAX. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.54 |
snTrapL4ContentVerificationThe SNMP trap that is generated when the HTTP match-list pattern
is found. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.55 |
snTrapDuplicateIpDuplicate IP address detected. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.56 |
snTrapMplsProblemNOT IMPLEMENTED: MPLS Problem Detected. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.57 |
snTrapMplsExceptionNOT IMPLEMENTED: MPLS Exception Detected. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.58 |
snTrapMplsAuditNOT IMPLEMENTED: MPLS Audit Trap. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.59 |
snTrapMplsDeveloperNOT IMPLEMENTED: MPLS Developer Trap. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.60 |
snTrapNoBmFreeQueueThe SNMP trap that is generated when no free queue is available in buffer manager. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.61 |
snTrapSmcDmaDropThe SNMP trap that is generated when SMC DMA packet is dropped. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.62 |
snTrapSmcBpDropThe SNMP trap that is generated when SMC BackPlane packet is dropped. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.63 |
snTrapBmWriteSeqDropThe SNMP trap that is generated when BM write sequence packet is dropped. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.64 |
snTrapBgpPeerUpThe SNMP trap that is generated when the bgp peer is up. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.65 |
snTrapBgpPeerDownThe SNMP trap that is generated when the bgp peer is down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.66 |
snTrapL4RealServerResponseTimeLowerLimitThe SNMP trap that is generated when the real server average response time exceeds lower threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.67 |
snTrapL4RealServerResponseTimeUpperLimitThe SNMP trap that is generated when the real server average response time exceeds upper threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.68 |
snTrapL4TcpAttackRateExceedMaxThe SNMP trap that is generated when the TCP attack rate exceeds configured maximum. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.69 |
snTrapL4TcpAttackRateExceedThresholdThe SNMP trap that is generated when the TCP attack rate exceeds 80% of configured maximum. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.70 |
snTrapL4ConnectionRateExceedMaxThe SNMP trap that is generated when the L4 connection rate exceeds configured maximum. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.71 |
snTrapL4ConnectionRateExceedThresholdThe SNMP trap that is generated when the L4 connection rate exceeds 80% of configured maximum NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.72 |
snTrapRunningConfigChangedThe SNMP trap that is generated when the running configuration
was changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.73 |
snTrapStartupConfigChangedThe SNMP trap that is generated when the startup configuration
was changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.74 |
snTrapUserLoginThe SNMP trap that is generated when user login. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.75 |
snTrapUserLogoutThe SNMP trap that is generated when user logout. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.76 |
snTrapPortSecurityViolationThe SNMP trap that is generated when insecure MAC addresses
are received from a port with MAC security feature enabled. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.77 |
snTrapPortSecurityShutdownThe SNMP trap that is generated when insecure MAC addresses
are received from a port caused the port to shutdown. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.78 |
snTrapMrpStateChangeThe SNMP trap that is generated when a MRP switching and routing device
changed state to disabled, blocking, preforwarding, forwarding, uknown. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.79 |
snTrapMrpCamErrorThe SNMP trap that is generated when a MRP Cam Error occurs. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.80 |
snTrapChasPwrSupplyOKThe SNMP trap that is generated when a power supply operational
status changed from failure to normal. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.81 |
snTrapVrrpeIfStateChangeThe SNMP trap that is generated when a VRRPE routing device
switched between states master, backup, intialized or uknown. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.82 |
snTrapVsrpIfStateChangeThe SNMP trap that is generated when a VSRP switching and routing device
switched between states master, backup, intialized or uknown. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.83 |
snTrapSrcIpAddressViolationThe SNMP trap that is generated when a rogue device spoofs source
IP address for denial of service attack. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.84 |
snTrapMacAuthEnableThe SNMP trap that is generated when MAC-Authentication is enabled
on an interface. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.85 |
snTrapMacAuthDisableThe SNMP trap that is generated when MAC-Authentication is disabled
on an interface. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.86 |
snTrapMacAuthMACAcceptedThe SNMP trap that is generated when MAC-Authentication is successful
on an interface. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.87 |
snTrapMacAuthMACRejectedThe SNMP trap that is generated when MAC-Authentication is failed
on an interface. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.88 |
snTrapMacAuthPortDisabledThe SNMP trap that is generated when an interface is disabled due to
MAC-Authentication detecting a DOS attack on that interface. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.89 |
snTrapClientLoginRejectThe SNMP trap that is generated when a login attempt by a
telnet or SSH client fails. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.110 |
snTrapLocalUserConfigChangeThe SNMP trap that is generated when a local user configuration is changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.111 |
snTrapVlanConfigChangeThe SNMP trap that is generated when a vlan configuration is changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.112 |
snTrapAclConfigChangeThe SNMP trap that is generated when a ACL configuration is changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.113 |
snTrapMacFilterConfigChangeThe SNMP trap that is generated when a MAC Filter configuration is changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.114 |
snTrapSNMPConfigChangeThe SNMP trap that is generated when a SNMP configuration is changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.115 |
snTrapSyslogConfigChangeThe SNMP trap that is generated when syslog is enabled/disabled
globally, or when a syslog server is added/deleted. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.116 |
snTrapPasswordConfigChangeThe SNMP trap that is generated when enable or line password is changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.117 |
snTrapServerStatusChangeThe SNMP trap that is generated when a server is disabled or enabled. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.118 |
snTrapL4RealServerPortMaxConnectionLimitReachedThe SNMP trap that is generated when the real server's port reaches
maximum number of connections. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.119 |
snTrapL4LinkDownThe SNMP trap that is generated when the ISP link goes down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.120 |
snTrapL4LinkUpThe SNMP trap that is generated when the ISP link goes up. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.121 |
snTrapPortPriorityChangeThe SNMP trap that is generated when the priority of a port is changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.122 |
snTrapAutoPortDisableTriggerThe SNMP trap that is generated when automatic port disable was triggered. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.123 |
snTrapAutoPortDisableReleaseThe SNMP trap that is generated when automatic port disable was released. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.124 |
snTrapPnPStatusChangeThe SNMP trap that is generated when plug-and-play status change. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.125 |
snTrapWirelessIsrpPeerStateChangeThe SNMP trap that is generated when ISRP Peer changes state. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.126 |
snTrapWirelessStationStateChangeThe SNMP trap that is generated when a wireless station's state changes. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.127 |
snTrapWirelessStationRoamingEventTriggeredThe SNMP trap that is generated when we received a MOVE request from
the AP NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.128 |
snTrapWirelessSappStateChangeThe SNMP trap that is generated when SAPP between an AP and a FIPS
changes state. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.129 |
snTrapExternalPowerConnectionStatusThe SNMP trap that is generated when the external power supply
connecting or disconnecting to a power over ethernet module. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.130 |
snTrapDot1xSecurityViolationThe SNMP trap that is generated when a malicious mac
address was detected. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.131 |
snTrapDot1xPortLinkChangeThe SNMP trap that is generated when software port link status
has changed to up or down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.132 |
snTrapDot1xPortControlChangeThe SNMP trap that is generated when software port control status
has changed to authorize or unauthorize. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.133 |
snTrapDot1xVlanIdChangeThe SNMP trap that is generated when VLAN ID of a port
has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.134 |
snTrapDot1xFilterSetupFailureThe SNMP trap that is generated when software failed
to setup a filter to a mac address of a port. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.135 |
snTrapDot1xErrorThe SNMP trap that is generated when software detected
system error. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.136 |
snTrapPortConfigChangeThe SNMP trap that is generated when a port configuration is changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.137 |
snTrapMacAuthVlanIdChangeThe SNMP trap that is generated when VLAN ID of a port
has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.138 |
snTrapWebAuthEnabledThe SNMP trap that is generated when web authentication is enabled. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.139 |
snTrapWebAuthDisabledThe SNMP trap that is generated when web authentication is disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.140 |
snTrapIpConfigChangeThe SNMP trap that is generated when IP system address changes. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.141 |
snTrapIpv6ConfigChangeThe SNMP trap that is generated when IPv6 system address changes. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.142 |
snTrapMacAuthRadiusTimeoutThe SNMP trap that is generated when a request from Mac-Auth
to RADIUS has not been answered within the retry and time limit. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.143 |
snTrapDot1xRadiusTimeoutThe SNMP trap that is generated when a request from 802.1x
to RADIUS has not been answered within the retry and time limit. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.144 |
snTrapUDLDLinkDownThe SNMP trap that is generated when UDLD port link status
has changed to down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.145 |
snTrapUDLDLinkUpThe SNMP trap that is generated when UDLD port link status
has changed to up. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.146 |
snTrapMacBasedVlanEnabledThe SNMP trap that is generated when MAC based VLAN is enabled. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.147 |
snTrapMacBasedVlanDisabledThe SNMP trap that is generated when MAC based VLAN is disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.148 |
snTrapChasFanNormalThe SNMP trap that is generated when a fan operational status
changed from failure to normal. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.149 |
snTrapStpRootGuardDetectThe SNMP trap that is generated when VLAN's Root-Guarded port received superior BPDU. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.150 |
snTrapStpRootGuardExpireThe SNMP trap that is generated when VLAN's ports's Root-Guard expire. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.151 |
snTrapStpBPDUGuardDetectThe SNMP trap that is generated when VLAN's BPDU-guarded port received BPDU . NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.152 |
snTrapMstpBPDUGuardDetectThe SNMP trap that is generated when BPDU-guarded port received BPDU . NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.153 |
snTrapErrorDisableActionThe SNMP trap that is generated when Interface error-disable is hit or recovery times out . NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.154 |
snTrapLACPLinkStateChangeThe SNMP trap that is generated when LACP port changes its state. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.155 |
snTrapOpticalMonitoringNotFoundryOpticsThe SNMP trap that is generated if optical monitoring is enabled but optics vendor is not Foundry Networks. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.156 |
snTrapOpticalMonitoringFoundryOpticsNotCapableThe SNMP trap that is generated if optical monitoring is enabled but the Foundry optic is not capable. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.157 |
snTrapStaticMulticastMacConfigAddThe SNMP trap that is generated if a new entry is added to static multicast mac configuration table.
Format 1: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is added to portnumber <port> on VLAN <id>
Format 2: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is added to portmask <0xXXXXXXXX-XXXXXXXX> on VLAN <id> NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.158 |
snTrapStaticMulticastMacConfigRemoveThe SNMP trap that is generated if an entry is removed from static multicast mac configuration table .
Format 1: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is deleted from portnumber <port> on VLAN <id>
Format 2: Static Mac entry with Mac Address <xxxx:xxxx:xxxx> is deleted from portmask <0xXXXXXXXX-XXXXXXXX> on VLAN <id> NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.159 |
snTrapSTPBPDUGuardExpireThe SNMP notification that is generated when a port is re-enabled after being disabled due to BPDU Guard Violation.
Format: STP: BPDU Guard re-enabled on VLAN <id> port <slot>/<port> NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.160 |
snTrapPortLoopDetectionThe SNMP notification is generated when a port loop is detected.
Format: LOOP DETECTION: VLAN <id>, port <slot>/<port> detect, putting into err-disable state NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.161 |
snTrapNoFreeTcamEntryThe SNMP trap that is generated when system is running out of TCAM spaces allocated for routing entries. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.162 |
snTrapStackingMasterElectedThe SNMP trap that is generated when a unit is elected as Master unit for the stacking system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.163 |
snTrapStackingUnitAddedThe SNMP trap that is generated when a unit has been added to the stacking system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.164 |
snTrapStackingUnitDeletedThe SNMP trap that is generated when a unit has been deleted from the stacking system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.165 |
snTrapStackingChasPwrSupplyOKThe SNMP trap that is generated when a power supply operational
status changed from failure to normal for a stacking system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.166 |
snTrapStackingChasPwrSupplyFailedThe SNMP trap that is generated when a power supply operational
status changed from normal to failure for a stacking system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.167 |
snTrapStackingChasFanNormalThe SNMP trap that is generated when a fan operational status
changed from failure to normal for a stacking system NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.168 |
snTrapStackingChasFanFailedThe SNMP trap that is generated when a fan fails
to operate normally for a stacking system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.169 |
snTrapStackingManagementMACChangedThe SNMP trap that is generated when the managemnet MAC
address of a stacking system has been changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.170 |
snTrapStackingTemperatureWarningThe SNMP trap that is generated when the actual temperature
reading is above the warning temperature threshold for a stack
sytem. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.171 |
snTrapIfIndexAssignmentChangedThe SNMP trap that is generated when the Interface Index (IfIndex)
assignment for the physical interfaces was changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.172 |
snTrapPBRConfigChangedThe SNMP trap that is generated when a Policy Based Routing (PBR) routemap
is bound or unbound either globally or to an interface. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.173 |
snTrapChasPwrSupplyRPSAddThe SNMP trap that is generated when an External Redundant
Power Supply (RPS2-EIF) is added to the system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.174 |
snTrapChasPwrSupplyRPSRemoveThe SNMP trap that is generated when an External Redundant
Power Supply (RPS2-EIF) is removed from the system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.175 |
snTrapModuleStatusChangeThe SNMP notification that is generated when a module's operational state changes.
The management entity receiving the notification can identify the
module and the event by referencing snChasUnitIndex, snAgentBrdIndex, snAgentBrdModuleStatus.
In case of a module-down event, the varbind snAgGblTrapMessage is a text string
that describes the cause. In case of module-up event, snAgGblTrapMessage is a null
string. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.176 |
snTrapChasHighSpeedFansNeededThe SNMP trap that is generated when chassis doesn't have high speed fans for specific modules NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.177 |
snTrapSysmaxRevertedThe SNMP trap that is generated when the revertible
sysmax elements are reverted during the card bringup
if they can not be accomodated in the available memory. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.178 |
snTrapSysmaxLeftLowMemThe SNMP trap that is generated when its found during bootup that
the configured sysmax set shall leave less than 10% available memory free. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.179 |
snTrapSysMemoryLowThresholdThe SNMP trap that is generated when the available dynamic memory
in a card is below 5% of the installed physical memory. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.180 |
snTrapSysMemoryOutThresholdThe SNMP trap that is generated when the dynamic memory
fails to be allocated in a system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.181 |
snTrapLinkOAMLinkDownThe SNMP trap that is generated when Link-OAM port link status
has changed to down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.182 |
snTrapLinkOAMLinkUpThe SNMP trap that is generated when Link-OAM port link status
has changed to up. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.183 |
snTrapI2CAccessLogThe SNMP trap that is generated to provide information about state of the management module's I2C accesses. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.184 |
snTrapLinkOAMLoopbackEnteredThe SNMP trap that is generated when Link-OAM port has entered
loopback mode. The link is not useful for data transfer any more. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.185 |
snTrapLinkOAMLoopbackClearedThe SNMP trap that is generated when Link-OAM port has entered
loopback mode. The link is not useful for data transfer any more. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.186 |
snTrapLicenseAddedThe SNMP trap that is generated when a new license is added to the system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.187 |
snTrapLicenseRemovedThe SNMP trap that is generated when an existing license is removed from the system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.188 |
snTrapLicenseExpiresThe SNMP trap that is generated when a trial license is about to expire. This trap is generated
daily for last 3 days and every 2 hours on the last day of expire. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.189 |
snTrapLicenseExpiredThe SNMP trap that is generated when a trial license has expired. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.190 |
snTrapUDLDCrcFailureDetectedThe SNMP trap that is generated when UDLD detects CRC failures on PDUs received on a port NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.191 |
snTrapDot1agCfmRemoteMEPAgeOutThe SNMP trap that is generated when 802.1ag Remote MEP ages out. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.192 |
snTrapDot1agCfmRemoteMEPUpThe SNMP trap that is generated when 802.1ag Remote MEP is up. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.193 |
snTrapDot1agCfmDomainCrossConnectionThe SNMP trap that is generated when 802.1ag domain gets cross-connected. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.194 |
snTrapDot1agCfmDuplicateMEPIdThe SNMP trap that is generated when 802.1ag Remote MEP reports a duplicate MEP Id
that conflicts with local MEP Id. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.195 |
snTrapStackingStandbyElectedThe SNMP trap that is generated when a unit is elected as Standby unit for the stacking system. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.196 |
snTrapMacMoveThresholdRateThe SNMP notification is generated when MAC movement exceeding the certain threshold for a sampling interval is detected.
Format: Mac-Move threshold-rate: MAC address <mac> moved from interface <port-id> to interface <port-id> for vlan <vlan-id>,
<move-count> times exceeding the threshold rate <threshold-rate> for a sampling interval <interval> seconds NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.197 |
snTrapMacMoveIntervalHistoryThe SNMP notification is generated every user configured interval, summarizing the moves in the interval .
Format: Mac-Move Interval-History: <#macs> macs moved in last <interval> seconds. Total number of mac moves in the interval is <#moves> NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.198 |
snTrapStackingMixedModeChangedThe SNMP trap that is generated when a stacking system mode is changed.
Format: The stacking system is changed to Mixed Stacking mode NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.199 |
snTrapSysMonErrorDetectThe SNMP notification is generated when SYSMON detects internal error. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.200 |
snTrapMacNotificationThe SNMP notification is generated when MAC event(s) is(are) detected.
Format: MAC-Event:MAC:<mac>-VLAN:<vlan-id>-PORT:<port-id>-ACT:<action>::MAC:<mac>-VLAN:<vlan-id>-PORT:<port-id>-ACT:<action>:: ...
...MAC:<mac>-VLAN:<vlan-id>-PORT:<port-id>-ACT:<action>::
where action: 1-MAC addition; 2-MAC deletion; 3-remove all MACs; 4-remove MAC from a port;
5-remove MAC from a VLAN; 6-remove MAC from a VLAN on a port NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.201 |
snTrapMacEventBufferFullThe SNMP notification is generated when MAC event buffer full is detected.
Format: MAC-Event: The Buffer is full, FDB table walk is required NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.202 |
snTrapStpDesignatedGuardDetectThe SNMP trap that is generated when VLAN's ports's Designated-Guard detect. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.203 |
snTrapStpDesignatedGuardDisableThe SNMP trap that is generated when VLAN's ports's Designated-Guard disable. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.204 |
snTrapLicenseNNLLTrialNotifyThe SNMP trap that is generated when a non-node locked licensed feature is enabled with
no a non-node locked license installed.
Format: Stack <stack_id>: Use of the <feature_name> feature requires a license to be purchased
and installed within <day> days. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.205 |
snTrapLicenseNNLLTrialExpiryThe SNMP trap that is generated when a non-node locked licensed feature is enabled after
30-44 days with no a non-node locked license installed. This message will be displayed 3 times
day 30, day 37, day 44.
Format: Stack <stack_id>: The <feature_name> feature has been activated for <day> days.
To ensure compliance, please purchase and install a license as soon as possible NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.206 |
snTrapLicenseNNLLNonCompliantThe SNMP trap that is generated when a non-node locked licensed feature is enabled after 45+ days
whit no a non-node locked license installed. Or deletion of an installed license if any of the
associated features are still enabled. This message will be displayed daily.
Format: Stack <stack_id>: THIS UNIT IS NOT COMPLIANT. A license for <feature_name> feature must
be purchased and installed or the feature <feature_name> must be deactivated to become compliant
with the terms and conditions of use NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.207 |
snTrapLicenseNNLLDeleteThe SNMP trap that is generated when a non-node locked licensed feature is enabled after a
non-node locked license is deleted.
Format: Stack <stack_id>: The <license_name> license has been deleted on this unit and is available
for redeployment on another unit in accordance with the terms and conditions of use. All features
associated to this license must be disabled NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.208 |
snTrapStackingShowStackConnectThe SNMP trap that is generated when the background diagnosis detects the connection errors
to notify the user to check the connections in a stacking system
Format: Background diagnosis detects connection errors. Please use show stack conn to
view detailed connections NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.209 |
snTrapStackingStandByChangedStandaloneThe SNMP trap that is generated when a unit is changed from Standby to Stand alone when the active unit is down. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.210 |
snTrapChasFanOKThe SNMP trap that is generated when a fan operational status
changed from failure to normal or change in the fan speed due to
temperature variations downwards. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1000 |
snTrapTemperatureOKThe SNMP trap that is generated when the actual temperature
reading is below the warning temperature threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1001 |
snTrapCAMOverflowThe SNMP trap that is generated when any CAM partition
becomes full. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1002 |
snTrapOpticalMonitoringWarningThe SNMP trap that is generated if there is a warning during optical
monitoring.
The first varbind, snAgGblTrapMessage, will have a detailed message on
the cause of event. The second optional varbind, ifIndex, points to the affected interface
originating this event. If an event does not have associated port, or has multiple
associated ports, then ifIndex will have maximum value 0x7ffffff. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1003 |
snTrapOpticalMonitoringAlarmThe SNMP trap that is generated if there is an alarm during optical
monitoring.
The first varbind, snAgGblTrapMessage, will have a detailed message on
the cause of event. The second optional varbind, ifIndex, points to the affected interface
originating this event. If an event does not have associated port, or has multiple
associated ports, then ifIndex will have maximum value 0x7ffffff. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1004 |
snTrapOpticalMonitoringErrorThe SNMP trap that is generated if there is an error during optical
monitoring.
The first varbind, snAgGblTrapMessage, will have a detailed message on
the cause of event. The second optional varbind, ifIndex, points to the affected interface
originating this event. If an event does not have associated port, or has multiple
associated ports, then ifIndex will have maximum value 0x7ffffff. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1005 |
snTrapPosMonitoringWarningThe SNMP trap that is generated if there is a warning during POS
alarm monitoring.
The first varbind, snAgGblTrapMessage, will have a detailed message on
the cause of event. The second optional varbind, ifIndex, points to the affected interface
originating this event. If an event does not have associated port, or has multiple
associated ports, then ifIndex will have maximum value 0x7ffffff. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1006 |
snTrapPosMonitoringAlarmThe SNMP trap that is generated if there is an alarm up/down
during POS alarm monitoring.
The first varbind, snAgGblTrapMessage, will have a detailed message on
the cause of event. The second optional varbind, ifIndex, points to the affected interface
originating this event. If an event does not have associated port, or has multiple
associated ports, then ifIndex will have maximum value 0x7ffffff. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1007 |
snTrapPosMonitoringErrorThe SNMP trap that is generated if there is an error during POS
alarm monitoring.
The first varbind, snAgGblTrapMessage, will have a detailed message on
the cause of event. The second optional varbind, ifIndex, points to the affected interface
originating this event. If an event does not have associated port, or has multiple
associated ports, then ifIndex will have maximum value 0x7ffffff. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1008 |
snTrapXfpSfpIncompatibleOpticsThe SNMP trap that is generated if optics is incompatible with port configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1009 |
snTrapTMLoggingStartThe SNMP trap that is generated if TM logging is started by an event trigger. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1015 |
snTrapTMLoggingStopThe SNMP trap that is generated if TM logging stopped due to storage full. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1016 |
snTrapTMLoggingRestartThe SNMP trap that is generated if TM logging restarted after user clearing the log. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1017 |
snTrapXfpSfpNotFoundryOpticsThe SNMP trap that is generated if optics vendor is not Foundry Networks. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1018 |
snTrapTMRecoverySlotResetThe SNMP trap that is generated when TM recovery slot reset is triggered. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1019 |
snTrapTMEgressDataErrorThe SNMP trap that is generated when system detects egress data errors on Traffic Manager.
For e.g. Fabric Monitoring : TM Egress data errors detected on LP <num>/TM <num> NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1020 |
snTrapSFMLoggingRestartThe SNMP trap that is generated if SFM logging restarted after user clearing the log. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1021 |
snTrapNotEnoughFapLinksThe SNMP trap that is generated when LP FAP (Fabric Adapter Processor)
has not enough links to maintain the line rate. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1035 |
snTrapSFMLinkDownThe SNMP trap that is generated when a link from LP Traffic Manager to
SFM Fabric Element is down.
For eg. Fabric Monitoring Link Down : SFM <num>/FE <num>/Link <num>, LP <num>/TM <num> NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1100 |
snTrapSFMLinkUpThe SNMP trap that is generated when a link from LP Traffic Manager to
SFM Fabric Element is up.
For eg. Fabric Monitoring Link Up : SFM <num>/FE <num>/Link <num>, LP <num>/TM <num> NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1101 |
snTrapSFMAccessErrorThe SNMP trap that is generated when system fails to access a SFM Fabric Element.
For e.g. Fabric Monitoring : Device access failure in SFM <num>/FE <num> NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1102 |
snTrapSFMStatusChangeThe SNMP notification that is generated when there is a change in the operational state
of the Switch Fabric Module (SFM). For example,
System: Health Monitoring: SFM <num> powered off due to failure detection NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1103 |
snTrapLPFabricStatusChangeHealth Monitoring: LP Fabric status change. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1104 |
snTrapModuleNPLockupIndicationThe SNMP notification that is generated for
the module's NP health monitoring to indicate
that a lockup and recovery have occurred.
Expressed in number of times in the past 1 hour NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1105 |
snTrapModuleNPLockupThresholdExceededThe SNMP notification that is generated for
the module's NP health monitoring when the
threshold for lockup and recovery of any NP
within the module have been reached.
The threshold value is 5 times in the past 1 hour. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1106 |
snTrapSFMAutoTuneStartThe SNMP trap that is generated when Auto tuning starts on the fabric side NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1107 |
snTrapSFMAutoTuneFailsThe SNMP trap that is generated when Auto tuning fails on the fabric side NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1108 |
snTrapSFMAutoTuneCompleteThe SNMP trap that is generated when Auto tuning completes on the fabric side NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1109 |
snTrapTMAutoTuneStartThe SNMP trap that is generated when Auto tuning starts on the TM side NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1110 |
snTrapTMAutoTuneFailsThe SNMP trap that is generated when Auto tuning fails on the TM side NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1111 |
snTrapTMAutoTuneCompleteThe SNMP trap that is generated when Auto tuning completes on the TM side NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1112 |
snTrapNPILKNCRCErrorThe SNMP trap that is generated when packet drops are observed in 2x100G ports because of Interlaken CRC errors NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1113 |
snTrapARPMACMovementThe SNMP trap that is generated when the MAC address associated with a host IP is changed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1114 |
snTrapChassisFanSpeedLowThe SNMP trap that is generated when all chassis fans change to low speed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1200 |
snTrapChassisFanSpeedMediumThe SNMP trap that is generated when all chassis fans change to medium speed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1201 |
snTrapChassisFanSpeedMedHighThe SNMP trap that is generated when all chassis fans change to medium high speed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1202 |
snTrapChassisFanSpeedHighThe SNMP trap that is generated when all chassis fans change to high speed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1203 |
snTrapFIPSModeEnableThe SNMP trap that is generated when FIPS mode is enabled. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1207 |
snTrapFIPSModeDisableThe SNMP trap that is generated when FIPS mode is disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1208 |
snTrapFIPSHostZeroizedThe SNMP trap that is generated when host keys are zeroized in FIPS mode NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1209 |
snTrapFIPSSharedSecretZeroizedThe SNMP trap that is generated when shared secret are zeroized in FIPS mode NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1210 |
snTrapFIPSPOSTStatusThe SNMP trap that is generated after POST. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1211 |
snTrapFIPSCryptoModuleFailureThe SNMP trap that is generated on cryptographic module failure. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1212 |
snTrapLicense2PortNotSupportedThe SNMP trap that is generated when a 2 port license cannot be applied due to hardware limitation. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1213 |
snTrapOpticalMonitoringOKThe SNMP trap that is generated when an interface transitions from an error to normal state because
the alarms/warnings are below the threshold. snTrapOpticalMonitoringError would have been earlier generated
when the interface transitioned to the error state. The first varbind, snAgGblTrapMessage, will have a detailed message on
the cause of event. The second varbind, ifIndex, points to the affected interface
originating this event. If an event does not have associated port, or has multiple
associated ports, then ifIndex will have maximum value 0x7ffffff. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1214 |
snTrapSFMAccessOKThe SNMP trap that is generated when system can successfully access an SFM Fabric Element.
snTrapSFMAccessError would have been generated when the system failed to access the FE.
For e.g. Fabric Monitoring : Device SFM <num>/FE <num> is OK to access. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1215 |
snTrapUpgradeSingleCmdStartThe SNMP trap that is generated when the single-command package
upgrade has started. This happens after a successful download
and validation of manifest file and before the first image download
takes place. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1216 |
snTrapUpgradeSingleCmdDoneThe SNMP trap that is generated when the single-command package
upgrade completed, or partially completed. The table
brcdSwPackageLoadResultTable lists the result of the upgrade. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1217 |
snTrapAutoUpgradeStartThe SNMP trap that is generated when an auto-upgrade on a line card
has started. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1218 |
snTrapAutoUpgradeDoneThe SNMP trap that is generated when the auto-upgrade of interface
module completed. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1219 |
snTrapTcamParityErrorThe SNMP trap that is generated when the TCAM parity errors are
detected on LP. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1220 |
snTrapLPResetOnTcamErrorThe SNMP trap that is generated when the LP reset due to TCAM parity errors crossing the threshold
or TCAM integrity check failure. NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1221 |
snTrapSTPRootGuardViolationThe SNMP trap that is generated when STP Root Guard Violation occurs on a port.
Format: STP: Root-protect port <slot>/<port>, VLAN <id> inconsistent (Received superior BPDU) NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1230 |
snTrapRSTPRootGuardViolationThe SNMP trap that is generated when STP Root Guard Violation occurs on a port.
Format: RSTP: Root-protect port <slot>/<port>, VLAN <id> inconsistent (Received superior BPDU) NOTIFICATION-TYPE .1.3.6.1.4.1.1991.0.1231 |