CISCO-FCOE-MIB
The CISCO-FCOE-MIB manages and monitors Cisco Fibre Channel over Ethernet (FCoE) infrastructure by exposing Virtual FC (VFC) interface states for VF_Port and VE_Port entities, alongside critical configuration parameters such as VSAN-to-VLAN mapping, FC-MAP values for FPMA mode, and FIP snooping attributes.
Imported Objects
Objects
38 total| Object Name |
|---|
ciscoFCoEMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.673 |
ciscoFCoEMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.673.1 |
cfcoeConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.673.1.1 |
cfcoeCfgTable SEQUENCE OF CfcoeCfgEntry .1.3.6.1.4.1.9.9.673.1.1.1 |
cfcoeCfgEntry CfcoeCfgEntry .1.3.6.1.4.1.9.9.673.1.1.1.1 |
cfcoeCfgFcmaprw OCTET STRING .1.3.6.1.4.1.9.9.673.1.1.1.1.1 |
cfcoeCfgDynamicVfcCreationrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.673.1.1.1.1.2 |
cfcoeCfgDynamicVfcAgeTimerrw Unsigned32 .1.3.6.1.4.1.9.9.673.1.1.1.1.3 |
cfcoeCfgDefaultFCFPriorityrw Unsigned32 .1.3.6.1.4.1.9.9.673.1.1.1.1.4 |
cfcoeCfgDATovrw Unsigned32 .1.3.6.1.4.1.9.9.673.1.1.1.1.5 |
cfcoeCfgAddressingModerw Enumeration .1.3.6.1.4.1.9.9.673.1.1.1.1.6 |
cfcoeVLANTable SEQUENCE OF CfcoeVLANEntry .1.3.6.1.4.1.9.9.673.1.1.2 |
cfcoeVLANEntry CfcoeVLANEntry .1.3.6.1.4.1.9.9.673.1.1.2.1 |
cfcoeVLANIndex VlanIndex (Q-BRIDGE-MIB) .1.3.6.1.4.1.9.9.673.1.1.2.1.1 |
cfcoeFabricIndex T11FabricIndex (T11-TC-MIB) .1.3.6.1.4.1.9.9.673.1.1.2.1.2 |
cfcoeVLANOperStatero Enumeration .1.3.6.1.4.1.9.9.673.1.1.2.1.3 |
cfcoeVLANRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.673.1.1.2.1.4 |
cfcoeStaticVfcTable SEQUENCE OF CfcoeStaticVfcEntry .1.3.6.1.4.1.9.9.673.1.1.3 |
cfcoeStaticVfcEntry CfcoeStaticVfcEntry .1.3.6.1.4.1.9.9.673.1.1.3.1 |
cfcoeStaticVfcIndex Unsigned32 .1.3.6.1.4.1.9.9.673.1.1.3.1.1 |
cfcoeStaticVfcFCFPriorityrw Unsigned32 .1.3.6.1.4.1.9.9.673.1.1.3.1.2 |
cfcoeStaticVfcBindTyperw VfcBindType .1.3.6.1.4.1.9.9.673.1.1.3.1.3 |
cfcoeStaticVfcBindIfIndexrw InterfaceIndexOrZero (IF-MIB) .1.3.6.1.4.1.9.9.673.1.1.3.1.4 |
cfcoeStaticVfcBindMACAddressrw MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.673.1.1.3.1.5 |
cfcoeStaticVfcIfIndexro InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.9.673.1.1.3.1.6 |
cfcoeStaticVfcCreationTimero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.9.673.1.1.3.1.7 |
cfcoeStaticVfcFailureCausero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.673.1.1.3.1.8 |
cfcoeStaticVfcRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.673.1.1.3.1.9 |
cfcoeFipSnoopingObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.673.1.2 |
cfcoeFipSnoopingEnablerw Enumeration .1.3.6.1.4.1.9.9.673.1.2.1 |
cfcoeFipSnoopingFcmaprw OCTET STRING .1.3.6.1.4.1.9.9.673.1.2.2 |
cfcoeEnodeIntfTable SEQUENCE OF CfcoeEnodeIntfEntry .1.3.6.1.4.1.9.9.673.1.2.3 |
cfcoeEnodeIntfEntry CfcoeEnodeIntfEntry .1.3.6.1.4.1.9.9.673.1.2.3.1 |
cfcoeEnodeIntfIfIndex InterfaceIndex (IF-MIB) .1.3.6.1.4.1.9.9.673.1.2.3.1.1 |
cfcoeEnodeIntfRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.673.1.2.3.1.2 |
ciscoFCoEMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.673.2 |
cFCoEMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.673.2.1 |
cFCoEMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.673.2.2 |
CISCO-FCOE-MIB Technical Reference Overview
The CISCO-FCOE-MIB SNMP MIB module published by Cisco defines 38 managed OID objects, including 23 scalar/column metrics, 4 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.673. Key tabular structures include cfcoeCfgTable, cfcoeVLANTable, cfcoeStaticVfcTable, cfcoeEnodeIntfTable.
Key OID Definitions in CISCO-FCOE-MIB
.1.3.6.1.4.1.9.9.673This MIB module is for configuring and monitoring Fibre Channel over Ethernet (FCoE) related entities. This MIB defines the Virtual FC (VFC) Interface as an object that represents either a VF_Port or a VE_Port on the FCF. Virtual FC interfaces can be either statically created or dynamically created at the time of FIP based FLOGI or ELP request. In this document the term VSAN ID is used interchangeably with Fabric Index defined in the T11 standards. Terminologies used in this MIB are defined by the T11 FCoE standard. Refer to www.t11.org. This MIB also supports configuration of the following objects: - Mapping of FCoE VLAN ID used to carry traffic for a VSAN ID - FC-MAP value used by the FCF operating in FPMA mode - FIP snooping related objects
.1.3.6.1.4.1.9.9.673.1.1.1This table facilitates configuration of FCoE parameters on a per Fibre Channel management instance.
.1.3.6.1.4.1.9.9.673.1.1.2This table facilitates configuration of VLAN and Fabric (VSAN) associations in an FCoE network. FCoE forwarding for a fabric is over a VLAN in a L2 Ethernet network. That is, reachability between the ENode/remote-FCF and an FCF for a given fabric is determined by the reachability provided by the Ethernet network on the corresponding VLAN. An active entry in this table indicates the VLAN that is used to transport FCoE traffic for a certain VSAN. Some implmentations may allow traffic from only one VSAN to be transported over a given VLAN. Such implmentations should prevent multiple entries with the same VLAN ID or the VSAN ID from being created in this table. Modifying existing VLAN-VSAN associations is not supported. Entries must be deleted first and then recreated.
.1.3.6.1.4.1.9.9.673.1.1.3This table facilitates the creation and deletion of static VFC interfaces. While VFCs can be dynamically created based on FIP FLOGI/ELP requests users may want to associate certain pre-configured policy for a particular ENode or a remote-FCF. In such cases static VFC creation becomes necessary. In addition to creating a static VFC it also needs to be associated to an ENode or remote-FCF. The VFC binding provides such an associaton. Binding may occur after a VFC is created.
.1.3.6.1.4.1.9.9.673.1.2.3The (conceptual) table containing the interfaces on an Ethernet bridge that are directly connected to ENodes. A FIP Snooping bridge will automatically configure ACLs on these interfaces based on FIP login requests and responses.
.1.3.6.1.4.1.9.9.673.1.2.1This object is used to enable or disable FIP Snooping on an Ethernet Bridge.
.1.3.6.1.4.1.9.9.673.1.2.2This object configures the FC-MAP value associated with the FIP snooping Ethernet bridge.
.1.3.6.1.4.1.9.9.673.1.1.1.1There is one entry in this table for each Fibre Channel management instance.
.1.3.6.1.4.1.9.9.673.1.1.1.1.1This object configures the FC-MAP value used by the FCF when operating in FPMA mode. The default value is 0EFC00h, as written in the standard.
.1.3.6.1.4.1.9.9.673.1.1.1.1.2This object allows the user to enable (TRUE) or disable (FALSE) dynamic VFC interface creation on the FCF. When set to TRUE VFC interfaces are dynamically created when a FIP based FLOGI or ELP request is received.
.1.3.6.1.4.1.9.9.673.1.1.1.1.3This ageing timer (in seconds) is used by the FCF to age out dynamically created VFC interfaces. The default value is 300 seconds.
.1.3.6.1.4.1.9.9.673.1.1.1.1.4The FIP priority value advertised by the FCF to ENodes by default. cfcoeStaticVfcFCFPriority configured for a VFC interface overrides this setting for the ENode associated with the VFC.
.1.3.6.1.4.1.9.9.673.1.1.1.1.5The Discovery_Advertisement_Timeout value configured for the FCF. This is used as the timeout value in seconds by the FCF to send periodic Discovery Advertisements.
.1.3.6.1.4.1.9.9.673.1.1.1.1.6Addressing mode(s) supported by the FCF. Implementations should fail set requests for unsupported modes.
.1.3.6.1.4.1.9.9.673.1.1.2.1There is one entry in this table for each VLAN that is designated to transport FCoE traffic for a given fabric (VSAN).
.1.3.6.1.4.1.9.9.673.1.1.2.1.1This object identifies the VLAN ID that FCoE FCF function is being enabled for.
.1.3.6.1.4.1.9.9.673.1.1.2.1.2This object identifies the Fabric Index of the VSAN traffic for which can be transported over the VLAN identified by cfcoeVLANIndex.
.1.3.6.1.4.1.9.9.673.1.1.2.1.3Operational state of this VLAN-VSAN association entry. The 'up' state is achieved when both the VSAN and VLAN are valid.
.1.3.6.1.4.1.9.9.673.1.1.2.1.4The status of this conceptual row. The RowStatus becomes active on successful creation of an entry.
.1.3.6.1.4.1.9.9.673.1.1.3.1There is one entry in this table for each statically created VFC Interface.
.1.3.6.1.4.1.9.9.673.1.1.3.1.1This index uniquely identifies a static VFC entry in this table.
.1.3.6.1.4.1.9.9.673.1.1.3.1.2If this VFC is for a VF_Port this object is used to configure FCF priority to be advertised to the ENode associated with the VFC.
.1.3.6.1.4.1.9.9.673.1.1.3.1.3The mechanism to identify the ENode associated with this VFC if it is of type VF_Port or to identify the remote-FCF associated with this VFC if it is of type VE_Port.
.1.3.6.1.4.1.9.9.673.1.1.3.1.4This object allows for configuration of ifIndex of the ethernet interface over which the FCF reaches the ENode or the remote-FCF that this VFC identifies. This object is to be used only when the ENode or the remote-FCF is directly connected to the FCF over a specific ethernet interface. If the ENode or remote-FCF is not directly connected to the FCF, this field must be set to zero.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.