FC-MGMT-MIB
Imported Objects
Objects
164 total| Object Name |
|---|
fcMgmtMIBThis module defines management information specific to Fibre Channel-attached devices. Copyright (C) The Internet Society (2005). This version of this MIB module is part of RFC 4044; see the RFC itself for full legal notices. MODULE-IDENTITY .1.3.6.1.2.1.10.56 |
fcmgmtObjects OBJECT IDENTIFIER .1.3.6.1.2.1.10.56.1 |
fcmInstanceTableInformation about the local Fibre Channel management instances. SEQUENCE OF FcmInstanceEntry .1.3.6.1.2.1.10.56.1.1 |
fcmInstanceEntryA list of attributes for a particular local Fibre Channel management instance. FcmInstanceEntry .1.3.6.1.2.1.10.56.1.1.1 |
fcmInstanceIndexAn arbitrary integer value that uniquely identifies this instance amongst all local Fibre Channel management instances. It is mandatory to keep this value constant between restarts of the agent, and to make every possible effort to keep it constant across restarts (but note, it is unrealistic to expect it to remain constant across all re-configurations of the local system, e.g., across the replacement of all non- volatile storage). Unsigned32 .1.3.6.1.2.1.10.56.1.1.1.1 |
fcmInstanceWwnIf the instance has one (or more) WWN(s), then this object contains that (or one of those) WWN(s). If the instance does not have a WWN associated with it, then this object contains the zero-length string.ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.1.1.2 |
fcmInstanceFunctionsOne (or more) Fibre Channel unit functions being performed by this instance.ro FcUnitFunctions .1.3.6.1.2.1.10.56.1.1.1.3 |
fcmInstancePhysicalIndexIf this management instance corresponds to a physical component (or to a hierarchy of physical components) identified by the Entity-MIB, then this object's value is the value of the entPhysicalIndex of that component (or of the component at the root of that hierarchy). If there is no correspondence to a physical component (or no component that has an entPhysicalIndex value), then the value of this object is zero.ro Integer32 .1.3.6.1.2.1.10.56.1.1.1.4 |
fcmInstanceSoftwareIndexIf this management instance corresponds to an installed software module identified in the Host Resources MIB, then this object's value is the value of the hrSWInstalledIndex of that module. If there is no correspondence to an installed software module (or no module that has a hrSWInstalledIndex value), then the value of this object is zero.ro Integer32 .1.3.6.1.2.1.10.56.1.1.1.5 |
fcmInstanceStatusOverall status of the Fibre Channel entity/entities managed by this management instance. The value should reflect the most serious status of such entities.ro Enumeration .1.3.6.1.2.1.10.56.1.1.1.6 |
fcmInstanceTextNameA textual name for this management instance and the Fibre Channel entity/entities that it is managing.rw SnmpAdminString .1.3.6.1.2.1.10.56.1.1.1.7 |
fcmInstanceDescrA textual description of this management instance and the Fibre Channel entity/entities that it is managing.rw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.2.1.10.56.1.1.1.8 |
fcmInstanceFabricIdThe globally unique Fabric Identifier that identifies the fabric to which the Fibre Channel entity/entities managed by this management instance are connected, or, of which they are a part. This is typically the Node WWN of the principal switch of a Fibre Channel fabric. The zero-length string indicates that the fabric identifier is unknown (or not applicable). In the event that the Fibre Channel entity/entities managed by this management instance is/are connected to multiple fabrics, then this object records the first (known) one.ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.1.1.9 |
fcmSwitchTableA table of information about Fibre Channel switches that are managed by Fibre Channel management instances. Each Fibre Channel management instance can manage one or more Fibre Channel switches. SEQUENCE OF FcmSwitchEntry .1.3.6.1.2.1.10.56.1.2 |
fcmSwitchEntryInformation about a particular Fibre Channel switch that is managed by the management instance given by fcmInstanceIndex. FcmSwitchEntry .1.3.6.1.2.1.10.56.1.2.1 |
fcmSwitchIndexAn arbitrary integer that uniquely identifies a Fibre Channel switch amongst those managed by one Fibre Channel management instance. It is mandatory to keep this value constant between restarts of the agent, and to make every possible effort to keep it constant across restarts. Unsigned32 .1.3.6.1.2.1.10.56.1.2.1.1 |
fcmSwitchDomainIdThe Domain Id of this switch. A value of zero indicates that a switch has not (yet) been assigned a Domain Id.rw FcDomainIdOrZero .1.3.6.1.2.1.10.56.1.2.1.2 |
fcmSwitchPrincipalAn indication of whether this switch is the principal switch within its fabric.ro TruthValue (SNMPv2-TC) .1.3.6.1.2.1.10.56.1.2.1.3 |
fcmSwitchWWNThe World Wide Name of this switch.ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.2.1.4 |
fcmPortTableInformation about Fibre Channel ports. Each Fibre Channel port is represented by one entry in the IF-MIB's ifTable. SEQUENCE OF FcmPortEntry .1.3.6.1.2.1.10.56.1.3 |
fcmPortEntryEach entry contains information about a specific port. FcmPortEntry .1.3.6.1.2.1.10.56.1.3.1 |
fcmPortInstanceIndexThe value of fcmInstanceIndex by which the Fibre Channel management instance, which manages this port, is identified in the fcmInstanceTable.ro Unsigned32 .1.3.6.1.2.1.10.56.1.3.1.1 |
fcmPortWwnThe World Wide Name of the port, or the zero-length string if the port does not have a WWN.ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.3.1.2 |
fcmPortNodeWwnThe World Wide Name of the Node that contains this port, or the zero-length string if the port does not have a node WWN.ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.3.1.3 |
fcmPortAdminTypeThe administratively desired type of this port.rw FcPortType .1.3.6.1.2.1.10.56.1.3.1.4 |
fcmPortOperTypeThe current operational type of this port.ro FcPortType .1.3.6.1.2.1.10.56.1.3.1.5 |
fcmPortFcCapClassThe classes of service capability of this port.ro FcClasses .1.3.6.1.2.1.10.56.1.3.1.6 |
fcmPortFcOperClassThe classes of service that are currently operational on this port. For an FL_Port, this is the union of the classes being supported across all attached NL_Ports.ro FcClasses .1.3.6.1.2.1.10.56.1.3.1.7 |
fcmPortTransmitterTypeThe technology of the port transceiver.ro Enumeration .1.3.6.1.2.1.10.56.1.3.1.8 |
fcmPortConnectorTypeThe module type of the port connector. This object refers to the hardware implementation of the port. It will be 'embedded' if the hardware equivalent to Gigabit interface card (GBIC) is part of the line card and is unremovable. It will be 'glm' if it's a gigabit link module (GLM). It will be 'gbicSerialId' if the GBIC serial id can be read, else it will be 'gbicNoSerialId'. It will be 'sfpSerialId' if the small form factor (SFP) pluggable GBICs serial id can be read, else it will be 'sfpNoSerialId'.ro Enumeration .1.3.6.1.2.1.10.56.1.3.1.9 |
fcmPortSerialNumberThe serial number associated with the port (e.g., for a GBIC). If not applicable, the object's value is a zero- length string.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.2.1.10.56.1.3.1.10 |
fcmPortPhysicalNumberThis is the port's 'Physical Port Number' as defined by GS-3.ro Unsigned32 .1.3.6.1.2.1.10.56.1.3.1.11 |
fcmPortAdminSpeedThe speed of the interface: 'auto' - auto-negotiation 'tenGbs' - 10Gbs 'fourGbs' - 4Gbs 'twoGbs' - 2Gbs 'oneGbs' - 1Gbs 'halfGbs' - 500Mbs 'quarterGbs' - 250Mbs 'eighthGbs' - 125Mbsrw Enumeration .1.3.6.1.2.1.10.56.1.3.1.12 |
fcmPortCapProtocolsA bit mask specifying the higher level protocols that are capable of running over this port. Note that for generic Fx_Ports, E_Ports, and B_Ports, this object will indicate all protocols.ro Bits .1.3.6.1.2.1.10.56.1.3.1.13 |
fcmPortOperProtocolsA bit mask specifying the higher level protocols that are currently operational on this port. For Fx_Ports, E_Ports, and B_Ports, this object will typically have the value 'unknown'.ro Bits .1.3.6.1.2.1.10.56.1.3.1.14 |
fcmPortStatsTableA list of statistics for Fibre Channel ports. SEQUENCE OF FcmPortStatsEntry .1.3.6.1.2.1.10.56.1.4 |
fcmPortStatsEntryAn entry containing statistics for a Fibre Channel port. If any counter in this table suffers a discontinuity, the value of ifCounterDiscontinuityTime (defined in the IF-MIB) must be updated. FcmPortStatsEntry .1.3.6.1.2.1.10.56.1.4.1 |
fcmPortBBCreditZerosThe number of transitions in/out of the buffer-to-buffer credit zero state. The other side is not providing any credit.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.1 |
fcmPortFullInputBuffersThe number of occurrences when all input buffers of a port were full and outbound buffer-to-buffer credit transitioned to zero, i.e., there became no credit to provide to other side.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.2 |
fcmPortClass2RxFramesThe number of Class 2 frames received at this port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.3 |
fcmPortClass2RxOctetsThe number of octets contained in Class 2 frames received at this port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.4 |
fcmPortClass2TxFramesThe number of Class 2 frames transmitted out of this port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.5 |
fcmPortClass2TxOctetsThe number of octets contained in Class 2 frames transmitted out of this port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.6 |
fcmPortClass2DiscardsThe number of Class 2 frames that were discarded upon reception at this port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.7 |
fcmPortClass2RxFbsyFramesThe number of times that F_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when either the fabric or the destination port is temporarily busy. Note that this counter will never increment for an F_Port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.8 |
fcmPortClass2RxPbsyFramesThe number of times that P_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when the destination port is temporarily busy.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.9 |
fcmPortClass2RxFrjtFramesThe number of times that F_RJT was returned to this port as a result of a Class 2 frame that was rejected by the fabric. Note that this counter will never increment for an F_Port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.10 |
fcmPortClass2RxPrjtFramesThe number of times that P_RJT was returned to this port as a result of a Class 2 frame that was rejected at the destination N_Port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.11 |
fcmPortClass2TxFbsyFramesThe number of times that F_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because either the Fabric or the destination port was temporarily busy. Note that this counter will never increment for an N_Port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.12 |
fcmPortClass2TxPbsyFramesThe number of times that P_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because the destination port was temporarily busy. Note that this counter will never increment for an F_Port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.13 |
fcmPortClass2TxFrjtFramesThe number of times that F_RJT was generated by this port as a result of a Class 2 frame being rejected by the fabric. Note that this counter will never increment for an N_Port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.14 |
fcmPortClass2TxPrjtFramesThe number of times that P_RJT was generated by this port as a result of a Class 2 frame being rejected at the destination N_Port. Note that this counter will never increment for an F_Port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.15 |
fcmPortClass3RxFramesThe number of Class 3 frames received at this port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.16 |
fcmPortClass3RxOctetsThe number of octets contained in Class 3 frames received at this port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.17 |
fcmPortClass3TxFramesThe number of Class 3 frames transmitted out of this port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.18 |
fcmPortClass3TxOctetsThe number of octets contained in Class 3 frames transmitted out of this port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.19 |
fcmPortClass3DiscardsThe number of Class 3 frames that were discarded upon reception at this port.ro Counter64 .1.3.6.1.2.1.10.56.1.4.1.20 |
fcmPortClassFRxFramesThe number of Class F frames received at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.4.1.21 |
fcmPortClassFRxOctetsThe number of octets contained in Class F frames received at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.4.1.22 |
fcmPortClassFTxFramesThe number of Class F frames transmitted out of this port.ro Counter32 .1.3.6.1.2.1.10.56.1.4.1.23 |
fcmPortClassFTxOctetsThe number of octets contained in Class F frames transmitted out of this port.ro Counter32 .1.3.6.1.2.1.10.56.1.4.1.24 |
fcmPortClassFDiscardsThe number of Class F frames that were discarded upon reception at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.4.1.25 |
fcmPortLcStatsTableA list of Counter32-based statistics for systems that do not support Counter64. SEQUENCE OF FcmPortLcStatsEntry .1.3.6.1.2.1.10.56.1.5 |
fcmPortLcStatsEntryAn entry containing low-capacity (i.e., based on Counter32) statistics for a Fibre Channel port. If any counter in this table suffers a discontinuity, the value of ifCounterDiscontinuityTime (defined in the IF-MIB) must be updated. FcmPortLcStatsEntry .1.3.6.1.2.1.10.56.1.5.1 |
fcmPortLcBBCreditZerosThe number of transitions in/out of the buffer-to-buffer credit zero state. The other side is not providing any credit.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.1 |
fcmPortLcFullInputBuffersThe number of occurrences when all input buffers of a port were full and outbound buffer-to-buffer credit transitioned to zero, i.e., there became no credit to provide to other side.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.2 |
fcmPortLcClass2RxFramesThe number of Class 2 frames received at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.3 |
fcmPortLcClass2RxOctetsThe number of octets contained in Class 2 frames received at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.4 |
fcmPortLcClass2TxFramesThe number of Class 2 frames transmitted out of this port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.5 |
fcmPortLcClass2TxOctetsThe number of octets contained in Class 2 frames transmitted out of this port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.6 |
fcmPortLcClass2DiscardsThe number of Class 2 frames that were discarded upon reception at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.7 |
fcmPortLcClass2RxFbsyFramesThe number of times that F_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when either the fabric or the destination port is temporarily busy. Note that this counter will never increment for an F_Port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.8 |
fcmPortLcClass2RxPbsyFramesThe number of times that P_BSY was returned to this port as a result of a Class 2 frame that could not be delivered to the other end of the link. This can occur when the destination port is temporarily busy.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.9 |
fcmPortLcClass2RxFrjtFramesThe number of times that F_RJT was returned to this port as a result of a Class 2 frame that was rejected by the fabric. Note that this counter will never increment for an F_Port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.10 |
fcmPortLcClass2RxPrjtFramesThe number of times that P_RJT was returned to this port as a result of a Class 2 frame that was rejected at the destination N_Port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.11 |
fcmPortLcClass2TxFbsyFramesThe number of times that F_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because either the Fabric or the destination port was temporarily busy. Note that this counter will never increment for an N_Port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.12 |
fcmPortLcClass2TxPbsyFramesThe number of times that P_BSY was generated by this port as a result of a Class 2 frame that could not be delivered because the destination port was temporarily busy. Note that this counter will never increment for an F_Port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.13 |
fcmPortLcClass2TxFrjtFramesThe number of times that F_RJT was generated by this port as a result of a Class 2 frame being rejected by the fabric. Note that this counter will never increment for an N_Port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.14 |
fcmPortLcClass2TxPrjtFramesThe number of times that P_RJT was generated by this port as a result of a Class 2 frame being rejected at the destination N_Port. Note that this counter will never increment for an F_Port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.15 |
fcmPortLcClass3RxFramesThe number of Class 3 frames received at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.16 |
fcmPortLcClass3RxOctetsThe number of octets contained in Class 3 frames received at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.17 |
fcmPortLcClass3TxFramesThe number of Class 3 frames transmitted out of this port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.18 |
fcmPortLcClass3TxOctetsThe number of octets contained in Class 3 frames transmitted out of this port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.19 |
fcmPortLcClass3DiscardsThe number of Class 3 frames that were discarded upon reception at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.5.1.20 |
fcmPortErrorsTableError counters for Fibre Channel ports. SEQUENCE OF FcmPortErrorsEntry .1.3.6.1.2.1.10.56.1.6 |
fcmPortErrorsEntryError counters for a Fibre Channel port. If any counter in this table suffers a discontinuity, the value of ifCounterDiscontinuityTime (defined in the IF-MIB) must be updated. FcmPortErrorsEntry .1.3.6.1.2.1.10.56.1.6.1 |
fcmPortRxLinkResetsThe number of Link Reset (LR) Primitive Sequences received.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.1 |
fcmPortTxLinkResetsThe number of Link Reset (LR) Primitive Sequences transmitted.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.2 |
fcmPortLinkResetsThe number of times the reset link protocol was initiated on this port. This includes the number of Loop Initialization Primitive (LIP) events on an arbitrated loop port.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.3 |
fcmPortRxOfflineSequencesThe number of Offline (OLS) Primitive Sequences received at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.4 |
fcmPortTxOfflineSequencesThe number of Offline (OLS) Primitive Sequences transmitted by this port.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.5 |
fcmPortLinkFailuresThe number of link failures. This count is part of FC-PH's Link Error Status Block (LESB).ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.6 |
fcmPortLossofSynchsThe number of instances of synchronization loss detected at this port. This count is part of FC-PH's Link Error Status Block (LESB).ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.7 |
fcmPortLossofSignalsThe number of instances of signal loss detected at this port. This count is part of FC-PH's Link Error Status Block (LESB).ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.8 |
fcmPortPrimSeqProtocolErrorsThe number of primitive sequence protocol errors detected at this port. This count is part of FC-PH's Link Error Status Block (LESB).ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.9 |
fcmPortInvalidTxWordsThe number of invalid transmission words received at this port. This count is part of FC-PH's Link Error Status Block (LESB).ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.10 |
fcmPortInvalidCRCsThe number of frames received with an invalid CRC. This count is part of FC-PH's Link Error Status Block (LESB).ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.11 |
fcmPortInvalidOrderedSetsThe number of invalid ordered sets received at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.12 |
fcmPortFrameTooLongsThe number of frames received at this port for which the frame length was greater than what was agreed to in FLOGI/PLOGI. This could be caused by losing the end of frame delimiter.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.13 |
fcmPortTruncatedFramesThe number of frames received at this port for which the frame length was less than the minimum indicated by the frame header - normally 24 bytes, but it could be more if the DFCTL field indicates an optional header should have been present.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.14 |
fcmPortAddressErrorsThe number of frames received with unknown addressing; for example, an unknown SID or DID.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.15 |
fcmPortDelimiterErrorsThe number of invalid frame delimiters received at this port. An example is a frame with a class 2 start and a class 3 at the end.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.16 |
fcmPortEncodingDisparityErrorsThe number of encoding disparity errors received at this port.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.17 |
fcmPortOtherErrorsThe number of errors that were detected on this port but not counted by any other error counter in this row.ro Counter32 .1.3.6.1.2.1.10.56.1.6.1.18 |
fcmFxPortTableAdditional information about Fibre Channel ports that is specific to Fx_Ports. This table will contain one entry for each fcmPortTable entry that represents an Fx_Port. SEQUENCE OF FcmFxPortEntry .1.3.6.1.2.1.10.56.1.7 |
fcmFxPortEntryEach entry contains information about a specific Fx_Port. FcmFxPortEntry .1.3.6.1.2.1.10.56.1.7.1 |
fcmFxPortRatovThe Resource_Allocation_Timeout Value configured for this Fx_Port. This is used as the timeout value for determining when to reuse an Nx_Port resource such as a Recovery_Qualifier. It represents the Error_Detect_Timeout value (see fcmFxPortEdtov) plus twice the maximum time that a frame may be delayed within the Fabric and still be delivered.ro Unsigned32 UNITS "milliseconds" .1.3.6.1.2.1.10.56.1.7.1.1 |
fcmFxPortEdtovThe Error_Detect_Timeout value configured for this Fx_Port. This is used as the timeout value for detecting an error condition.ro Unsigned32 UNITS "milliseconds" .1.3.6.1.2.1.10.56.1.7.1.2 |
fcmFxPortRttovThe Receiver_Transmitter_Timeout value of this Fx_Port. This is used by the receiver logic to detect a Loss of Synchronization.ro Unsigned32 UNITS "milliseconds" .1.3.6.1.2.1.10.56.1.7.1.3 |
fcmFxPortHoldTimeThe maximum time that this Fx_Port shall hold a frame before discarding the frame if it is unable to deliver the frame. The value 0 means that this Fx_Port does not support this parameter.ro Unsigned32 UNITS "microseconds" .1.3.6.1.2.1.10.56.1.7.1.4 |
fcmFxPortCapBbCreditMaxThe maximum number of receive buffers that this port is capable of making available for holding frames from attached Nx_Port(s).ro FcBbCredit UNITS "buffers" .1.3.6.1.2.1.10.56.1.7.1.5 |
fcmFxPortCapBbCreditMinThe minimum number of receive buffers that this port is capable of making available for holding frames from attached Nx_Port(s).ro FcBbCredit UNITS "buffers" .1.3.6.1.2.1.10.56.1.7.1.6 |
fcmFxPortCapDataFieldSizeMaxThe maximum size in bytes of the Data Field in a frame that this Fx_Port is capable of receiving from an attached Nx_Port.ro FcDataFieldSize UNITS "bytes" .1.3.6.1.2.1.10.56.1.7.1.7 |
fcmFxPortCapDataFieldSizeMinThe minimum size in bytes of the Data Field in a frame that this Fx_Port is capable of receiving from an attached Nx_Port.ro FcDataFieldSize UNITS "bytes" .1.3.6.1.2.1.10.56.1.7.1.8 |
fcmFxPortCapClass2SeqDelivAn indication of whether this Fx_Port is capable of supporting Class 2 Sequential Delivery.ro TruthValue (SNMPv2-TC) .1.3.6.1.2.1.10.56.1.7.1.9 |
fcmFxPortCapClass3SeqDelivAn indication of whether this Fx_Port is capable of supporting Class 3 Sequential Delivery.ro TruthValue (SNMPv2-TC) .1.3.6.1.2.1.10.56.1.7.1.10 |
fcmFxPortCapHoldTimeMaxThe maximum holding time that this Fx_Port is capable of supporting.ro Unsigned32 UNITS "microseconds" .1.3.6.1.2.1.10.56.1.7.1.11 |
fcmFxPortCapHoldTimeMinThe minimum holding time that this Fx_Port is capable of supporting.ro Unsigned32 UNITS "microseconds" .1.3.6.1.2.1.10.56.1.7.1.12 |
fcmISPortTableAdditional information about E_Ports, B_Ports, and any other type of Fibre Channel port to which inter-switch links can be connected. This table will contain one entry for each fcmPortTable entry that represents such a port. SEQUENCE OF FcmISPortEntry .1.3.6.1.2.1.10.56.1.8 |
fcmISPortEntryEach entry contains information about a specific port connected to an inter-switch link. FcmISPortEntry .1.3.6.1.2.1.10.56.1.8.1 |
fcmISPortClassFCreditThe maximum number of Class F data frames that can be transmitted by the inter-switch port without receipt of ACK or Link_Response frames.rw FcBbCredit .1.3.6.1.2.1.10.56.1.8.1.1 |
fcmISPortClassFDataFieldSizeThe Receive Data Field Size that the inter-switch port has agreed to support for Class F frames to/from this port. The size specifies the largest Data Field Size for an FT_1 frame.ro FcDataFieldSize UNITS "bytes" .1.3.6.1.2.1.10.56.1.8.1.2 |
fcmFLoginTableA table that contains one entry for each Nx_Port logged- in/attached to a particular Fx_Port in the switch. Each entry contains the services parameters established during the most recent Fabric Login, explicit or implicit. Note that an Fx_Port may have one or more Nx_Ports attached to it. SEQUENCE OF FcmFLoginEntry .1.3.6.1.2.1.10.56.1.9 |
fcmFLoginEntryAn entry containing service parameters established from a successful Fabric Login. FcmFLoginEntry .1.3.6.1.2.1.10.56.1.9.1 |
fcmFLoginNxPortIndexAn arbitrary integer that uniquely identifies an Nx_Port amongst all those attached to the Fx_Port indicated by ifIndex. After a value of this object is assigned to a particular Nx_Port, that value can be re-used when and only when it is assigned to the same Nx_Port, or, after a reset of the value of the relevant instance of ifCounterDiscontinuityTime. Unsigned32 .1.3.6.1.2.1.10.56.1.9.1.1 |
fcmFLoginPortWwnThe port name of the attached Nx_Port, or the zero-length string if unknown.ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.9.1.2 |
fcmFLoginNodeWwnThe node name of the attached Nx_Port, or the zero-length string if unknown.ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.9.1.3 |
fcmFLoginBbCreditModelThe buffer-to-buffer credit model in use by the Fx_Port.ro FcBbCreditModel .1.3.6.1.2.1.10.56.1.9.1.4 |
fcmFLoginBbCreditThe number of buffers available for holding frames to be transmitted to the attached Nx_Port. These buffers are for buffer-to-buffer flow control in the direction from Fx_Port to Nx_Port.ro FcBbCredit .1.3.6.1.2.1.10.56.1.9.1.5 |
fcmFLoginClassesAgreedThe Classes of Service that the Fx_Port has agreed to support for this Nx_Port.ro FcClasses .1.3.6.1.2.1.10.56.1.9.1.6 |
fcmFLoginClass2SeqDelivAgreedAn indication of whether the Fx_Port has agreed to support Class 2 sequential delivery for this Nx_Port. This is only meaningful if Class 2 service has been agreed upon.ro TruthValue (SNMPv2-TC) .1.3.6.1.2.1.10.56.1.9.1.7 |
fcmFLoginClass2DataFieldSizeThe Receive Data Field Size that the Fx_Port has agreed to support for Class 2 frames to/from this Nx_Port. The size specifies the largest Data Field Size for an FT_1 frame. This is only meaningful if Class 2 service has been agreed upon.ro FcDataFieldSize .1.3.6.1.2.1.10.56.1.9.1.8 |
fcmFLoginClass3SeqDelivAgreedAn indication of whether the Fx_Port has agreed to support Class 3 sequential delivery for this Nx_Port. This is only meaningful if Class 3 service has been agreed upon.ro TruthValue (SNMPv2-TC) .1.3.6.1.2.1.10.56.1.9.1.9 |
fcmFLoginClass3DataFieldSizeThe Receive Data Field Size that the Fx_Port has agreed to support for Class 3 frames to/from this Nx_Port. The size specifies the largest Data Field Size for an FT_1 frame. This is only meaningful if Class 3 service has been agreed upon.ro FcDataFieldSize .1.3.6.1.2.1.10.56.1.9.1.10 |
fcmLinkTableA table containing any Fibre Channel link information that is known to local Fibre Channel managed instances. One end of such a link is typically at a local port, but the table can also contain information on links for which neither end is a local port. If one end of a link terminates locally, then that end is termed 'end1'; the other end is termed 'end2'. SEQUENCE OF FcmLinkEntry .1.3.6.1.2.1.10.56.1.10 |
fcmLinkEntryAn entry containing information that a particular Fibre Channel managed instance has about a Fibre Channel link. The two ends of the link are called 'end1' and 'end2'. FcmLinkEntry .1.3.6.1.2.1.10.56.1.10.1 |
fcmLinkIndexAn arbitrary integer that uniquely identifies one link within the set of links about which a particular managed instance has information. Unsigned32 .1.3.6.1.2.1.10.56.1.10.1.1 |
fcmLinkEnd1NodeWwnThe node name of end1, or the zero-length string if unknown.ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.10.1.2 |
fcmLinkEnd1PhysPortNumberThe physical port number of end1, or zero if unknown.ro Unsigned32 .1.3.6.1.2.1.10.56.1.10.1.3 |
fcmLinkEnd1PortWwnThe port WWN of end1, or the zero-length string if unknown. ('end1' is local if this value is equal to the value of fcmPortWwn in one of the rows of the fcmPortTable.)ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.10.1.4 |
fcmLinkEnd2NodeWwnThe node name of end2, or the zero-length string if unknown.ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.10.1.5 |
fcmLinkEnd2PhysPortNumberThe physical port number of end2, or zero if unknown.ro Unsigned32 .1.3.6.1.2.1.10.56.1.10.1.6 |
fcmLinkEnd2PortWwnThe port WWN of end2, or the zero-length string if unknown.ro FcNameIdOrZero .1.3.6.1.2.1.10.56.1.10.1.7 |
fcmLinkEnd2AgentAddressThe address of the management agent for the Fibre Channel Interconnect Element or Platform of which end2 is a part. The GS-4 specification provides some information about management agents. If the address is unknown, the value of this object is the zero-length string.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.2.1.10.56.1.10.1.8 |
fcmLinkEnd2PortTypeThe port type of end2.ro FcPortType .1.3.6.1.2.1.10.56.1.10.1.9 |
fcmLinkEnd2UnitTypeThe type of/function(s) performed by the Fibre Channel Interconnect Element or Platform of which end2 is a part.ro FcUnitFunctions .1.3.6.1.2.1.10.56.1.10.1.10 |
fcmLinkEnd2FcAddressIdThe Fibre Channel Address ID of end2, or the zero-length string if unknown.ro FcAddressIdOrZero .1.3.6.1.2.1.10.56.1.10.1.11 |
fcmgmtNotifications OBJECT IDENTIFIER .1.3.6.1.2.1.10.56.2 |
fcmgmtNotifPrefix OBJECT IDENTIFIER .1.3.6.1.2.1.10.56.2.0 |
fcmgmtConformance OBJECT IDENTIFIER .1.3.6.1.2.1.10.56.3 |
fcmgmtCompliances OBJECT IDENTIFIER .1.3.6.1.2.1.10.56.3.1 |
fcmgmtComplianceDescribes the requirements for compliance to this Fibre Channel Management MIB. Unknown .1.3.6.1.2.1.10.56.3.1.1 |
fcmgmtGroups OBJECT IDENTIFIER .1.3.6.1.2.1.10.56.3.2 |
fcmInstanceBasicGroupBasic information about Fibre Channel managed instances. Unknown .1.3.6.1.2.1.10.56.3.2.1 |
fcmSwitchBasicGroupBasic information about Fibre Channel switches. Unknown .1.3.6.1.2.1.10.56.3.2.2 |
fcmPortBasicGroupBasic information about Fibre Channel ports. Unknown .1.3.6.1.2.1.10.56.3.2.3 |
fcmPortStatsGroupTraffic statistics, which are not specific to any one class of service, for Fibre Channel ports. Unknown .1.3.6.1.2.1.10.56.3.2.4 |
fcmPortClass23StatsGroupTraffic statistics for Class 2 and Class 3 traffic on Fibre Channel ports. Unknown .1.3.6.1.2.1.10.56.3.2.5 |
fcmPortClassFStatsGroupTraffic statistics for Class F traffic on Fibre Channel ports. Unknown .1.3.6.1.2.1.10.56.3.2.6 |
fcmPortLcStatsGroupLow-capacity (32-bit) statistics for Fibre Channel ports. Unknown .1.3.6.1.2.1.10.56.3.2.7 |
fcmPortErrorsGroupError statistics for Fibre Channel ports. Unknown .1.3.6.1.2.1.10.56.3.2.8 |
fcmSwitchPortGroupInformation about ports on a Fibre Channel switch. Unknown .1.3.6.1.2.1.10.56.3.2.9 |
fcmSwitchLoginGroupInformation known to a Fibre Channel switch about attached/logged-in Nx_Ports. Unknown .1.3.6.1.2.1.10.56.3.2.10 |
fcmLinkBasicGroupInformation about Fibre Channel links. Unknown .1.3.6.1.2.1.10.56.3.2.11 |
More MIBs from Default
Browse all DefaultMIBs →SNMP MIB module
The AVAYA-WLAN-MIB provides SNMP-based management and monitoring capabilities for Avaya wireless LAN infrastructure, enabling the collection of performance metrics such as access point status, client association counts, signal strength, and radio interface statistics. This module facilitates the tracking of WLAN-specific events and configuration parameters to support network availability and troubleshooting within Avaya wireless deployments.
The VMWARE-NSX-MIB enables SNMP-based monitoring and management of VMware NSX-T Data Center virtual network infrastructure, exposing metrics for logical switches, routers, distributed firewalls, and overlay tunnel states. It facilitates the tracking of Layer 2 through Layer 7 service instances, including access control lists, Quality of Service policies, and virtual network topology changes within the software-defined networking environment.
Standard SNMP MIB module defining data structures for 923switch.m.
Standard SNMP MIB module defining data structures for CTATX-MIB.
SNMP MIB module