VMWARE-NSX-MIB
The VMWARE-NSX-MIB enables SNMP-based monitoring and management of VMware NSX-T Data Center virtual network infrastructure, exposing metrics for logical switches, routers, distributed firewalls, and overlay tunnel states. It facilitates the tracking of Layer 2 through Layer 7 service instances, including access control lists, Quality of Service policies, and virtual network topology changes within the software-defined networking environment.
Imported Objects
Objects
870 total| Object Name |
|---|
vmwNSXsysMIB MODULE-IDENTITY .vmwNSXsys.1 |
vmwNsxTDataCenterNotifications OBJECT IDENTIFIER .vmwNSXsys.1.0 |
vmwNsxTManagerHealthFeaturePrefix OBJECT IDENTIFIER .vmwNSXsys.1.0.1 |
vmwNsxTManagerHealthFeature OBJECT IDENTIFIER .vmwNSXsys.1.0.1.0 |
vmwNsxTManagerHealthManagerCPUUsageHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.1 |
vmwNsxTManagerHealthManagerCPUUsageHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.2 |
vmwNsxTManagerHealthManagerCPUUsageVeryHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.3 |
vmwNsxTManagerHealthManagerCPUUsageVeryHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.4 |
vmwNsxTManagerHealthManagerMemoryUsageHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.5 |
vmwNsxTManagerHealthManagerMemoryUsageHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.6 |
vmwNsxTManagerHealthManagerMemoryUsageVeryHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.7 |
vmwNsxTManagerHealthManagerMemoryUsageVeryHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.8 |
vmwNsxTManagerHealthManagerDiskUsageHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.9 |
vmwNsxTManagerHealthManagerDiskUsageHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.10 |
vmwNsxTManagerHealthManagerDiskUsageVeryHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.11 |
vmwNsxTManagerHealthManagerDiskUsageVeryHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.12 |
vmwNsxTManagerHealthManagerConfigDiskUsageHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.13 |
vmwNsxTManagerHealthManagerConfigDiskUsageHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.14 |
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.15 |
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.16 |
vmwNsxTManagerHealthDuplicateIPAddress NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.17 |
vmwNsxTManagerHealthDuplicateIPAddressClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.18 |
vmwNsxTManagerHealthOperationsDbDiskUsageHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.19 |
vmwNsxTManagerHealthOperationsDbDiskUsageHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.20 |
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.21 |
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.22 |
vmwNsxTManagerHealthStorageError NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.23 |
vmwNsxTManagerHealthStorageErrorClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.24 |
vmwNsxTManagerHealthMissingDNSEntryForManagerFQDN NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.28 |
vmwNsxTManagerHealthMissingDNSEntryForManagerFQDNClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.29 |
vmwNsxTManagerHealthMissingDNSEntryForVipFQDN NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.33 |
vmwNsxTManagerHealthMissingDNSEntryForVipFQDNClear NOTIFICATION-TYPE .vmwNSXsys.1.0.1.0.34 |
vmwNsxTEdgeHealthFeaturePrefix OBJECT IDENTIFIER .vmwNSXsys.1.0.2 |
vmwNsxTEdgeHealthFeature OBJECT IDENTIFIER .vmwNSXsys.1.0.2.0 |
vmwNsxTEdgeHealthEdgeCPUUsageHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.1 |
vmwNsxTEdgeHealthEdgeCPUUsageHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.2 |
vmwNsxTEdgeHealthEdgeCPUUsageVeryHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.3 |
vmwNsxTEdgeHealthEdgeCPUUsageVeryHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.4 |
vmwNsxTEdgeHealthEdgeMemoryUsageHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.5 |
vmwNsxTEdgeHealthEdgeMemoryUsageHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.6 |
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.7 |
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.8 |
vmwNsxTEdgeHealthEdgeDiskUsageHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.9 |
vmwNsxTEdgeHealthEdgeDiskUsageHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.10 |
vmwNsxTEdgeHealthEdgeDiskUsageVeryHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.11 |
vmwNsxTEdgeHealthEdgeDiskUsageVeryHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.12 |
vmwNsxTEdgeHealthEdgeDatapathCPUHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.17 |
vmwNsxTEdgeHealthEdgeDatapathCPUHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.18 |
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.19 |
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.20 |
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailure NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.21 |
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailureClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.22 |
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDown NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.23 |
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDownClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.24 |
vmwNsxTEdgeHealthEdgeDatapathMempoolHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.25 |
vmwNsxTEdgeHealthEdgeDatapathMempoolHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.26 |
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.27 |
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.28 |
vmwNsxTEdgeHealthEdgeNICLinkStatusDown NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.29 |
vmwNsxTEdgeHealthEdgeNICLinkStatusDownClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.30 |
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBuffer NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.31 |
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBufferClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.32 |
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBuffer NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.33 |
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBufferClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.34 |
vmwNsxTEdgeHealthStorageError NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.37 |
vmwNsxTEdgeHealthStorageErrorClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.38 |
vmwNsxTEdgeHealthDatapathThreadDeadlocked NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.45 |
vmwNsxTEdgeHealthDatapathThreadDeadlockedClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.46 |
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.49 |
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.50 |
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHigh NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.51 |
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.52 |
vmwNsxTEdgeHealthFailureDomainDown NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.53 |
vmwNsxTEdgeHealthFailureDomainDownClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.54 |
vmwNsxTEdgeHealthMegaFlowCacheHitRateLow NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.55 |
vmwNsxTEdgeHealthMegaFlowCacheHitRateLowClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.56 |
vmwNsxTEdgeHealthMicroFlowCacheHitRateLow NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.57 |
vmwNsxTEdgeHealthMicroFlowCacheHitRateLowClear NOTIFICATION-TYPE .vmwNSXsys.1.0.2.0.58 |
vmwNsxTCertificatesFeaturePrefix OBJECT IDENTIFIER .vmwNSXsys.1.0.3 |
vmwNsxTCertificatesFeature OBJECT IDENTIFIER .vmwNSXsys.1.0.3.0 |
vmwNsxTCertificatesCertificateExpirationApproaching NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.1 |
vmwNsxTCertificatesCertificateExpirationApproachingClear NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.2 |
vmwNsxTCertificatesCertificateExpired NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.3 |
vmwNsxTCertificatesCertificateExpiredClear NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.4 |
vmwNsxTCertificatesCertificateIsAboutToExpire NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.5 |
vmwNsxTCertificatesCertificateIsAboutToExpireClear NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.6 |
vmwNsxTCertificatesCABundleUpdateRecommended NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.7 |
vmwNsxTCertificatesCABundleUpdateRecommendedClear NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.8 |
vmwNsxTCertificatesCABundleUpdateSuggested NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.9 |
vmwNsxTCertificatesCABundleUpdateSuggestedClear NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.10 |
vmwNsxTCertificatesTransportNodeCertificateExpirApproaching NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.17 |
vmwNsxTCertificatesTransportNodeCertificateExpirApproachingClear NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.18 |
vmwNsxTCertificatesTransportNodeCertificateExpired NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.19 |
vmwNsxTCertificatesTransportNodeCertificateExpiredClear NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.20 |
vmwNsxTCertificatesTransportNodeCertificateIsAboutToExpire NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.21 |
vmwNsxTCertificatesTransportNodeCertificateIsAboutToExpireClear NOTIFICATION-TYPE .vmwNSXsys.1.0.3.0.22 |
vmwNsxTPasswordManagementFeaturePrefix OBJECT IDENTIFIER .vmwNSXsys.1.0.4 |
vmwNsxTPasswordManagementFeature OBJECT IDENTIFIER .vmwNSXsys.1.0.4.0 |
vmwNsxTPasswordManagementPasswordExpirationApproaching NOTIFICATION-TYPE .vmwNSXsys.1.0.4.0.1 |
vmwNsxTPasswordManagementPasswordExpirationApproachingClear NOTIFICATION-TYPE .vmwNSXsys.1.0.4.0.2 |
VMWARE-NSX-MIB Technical Reference Overview
The VMWARE-NSX-MIB SNMP MIB module published by Default defines 870 managed OID objects, including 166 scalar/column metrics, 0 SNMP tables, and 608 trap/notification events anchored at base OID .vmwNSXsys.1. Monitored SNMP traps/notifications include vmwNsxTAlarmManagementAlarmServiceOverloaded, vmwNsxTAlarmManagementAlarmServiceOverloadedClear, vmwNsxTAlarmManagementHeavyVolumeOfAlarms, vmwNsxTAlarmManagementHeavyVolumeOfAlarmsClear, vmwNsxTAuditLogHealthAuditLogFileUpdateError, vmwNsxTAuditLogHealthAuditLogFileUpdateErrorClear.
Key OID Definitions in VMWARE-NSX-MIB
.vmwNSXsys.1In much the same way that server virtualization programmatically creates, snapshots, deletes, and restores software-based virtual machines (VMs), NSX Data Center network virtualization programmatically creates, deletes, and restores software-based virtual networks. With network virtualization, the functional equivalent of a network hypervisor reproduces the complete set of Layer 2 through Layer 7 networking services (for example, switching, routing, access control, firewalling, QoS) in software. As a result, these services can be programmatically assembled in any arbitrary combination, to produce unique, isolated virtual networks in a matter of seconds. For more information about NSX Data Center, please visit: https://docs.vmware.com/en/VMware-NSX-T-Data-Center/
.vmwNSXsys.1.0.16.0.1Due to heavy volume of alarms reported, the alarm service is temporarily overloaded. The NSX UI and GET /api/v1/alarms NSX API have stopped reporting new alarms; however, syslog entries and SNMP traps (if enabled) are still being emitted reporting the underlying event details. When the underlying issues causing the heavy volume of alarms are addressed, the alarm service will start reporting new alarms again. Action required: Review all active alarms using the Alarms page in the NSX UI or using the GET /api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED NSX API. For each active alarm investigate the root cause by following the recommended action for the alarm. When sufficient alarms are resolved, the alarm service will start reporting new alarms again.
.vmwNSXsys.1.0.16.0.2The heavy volume of alarms has subsided and new alarms are being reported again. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.16.0.3Due to heavy volume of vmwNsxTDataCenterEventId alarms, the alarm service has temporarily stopped reporting alarms of this type. The NSX UI and GET /api/v1/alarms NSX API are not reporting new instances of these alarms; however, syslog entries and SNMP traps (if enabled) are still being emitted reporting the underlying event details. When the underlying issues causing the heavy volume of vmwNsxTDataCenterEventId alarms are addressed, the alarm service will start reporting new vmwNsxTDataCenterEventId alarms when new issues are detected again. Action required: Review all active alarms of type vmwNsxTDataCenterEventId using the Alarms page in the NSX UI or using the NSX API GET /api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED. For each active alarm investigate the root cause by following the recommended action for the alarm. When sufficient alarms are resolved, the alarm service will start reporting new vmwNsxTDataCenterEventId alarms again.
.vmwNSXsys.1.0.16.0.4The heavy volume of vmwNsxTDataCenterEventId alarms has subsided and new alarms of this type are being reported again. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.24.0.1At least one of the monitored log files has read-only permissions or has incorrect user/group ownership on Manager, Global Manager, Edge, Public Cloud Gateway, KVM or Linux Physical Server nodes. Or log folder is missing in Windows Physical Server nodes. Or rsyslog.log is missing on Manager, Global Manager, Edge or Public Cloud Gateway nodes. Action required: 1. On Manager and Global Managaer nodes, Edge and Public Cloud Gateway nodes, Ubuntu KVM Host nodes ensure the permissions for the /var/log directory is 775 and the ownership is root:syslog. One Rhel KVM and BMS Host nodes ensure the permission for the /var/log directory is 755 and the ownership is root:root. 2. On Manager and Global Manager nodes, ensure the file permissions for auth.log, nsx-audit.log, nsx-audit-write.log, rsyslog.log and syslog under /var/log is 640 and ownership is syslog:admin. 3. On Edge and Public Cloud Gateway nodes, ensure the file permissions for rsyslog.log and syslog under /var/log is 640 and ownership is syslog:admin. 4. On Ubuntu KVM Host and Ubuntu Physical Server nodes, ensure the file permissions of auth.log and vmware/nsx-syslog under /var/log is 640 and ownership is syslog:admin. 5. On Rhel KVM Host nodes and Centos/Rhel/Sles Physical Server nodes, ensure the file permission of vmware/nsx-syslog under /var/log is 640 and ownership is root:root. 6. If any of these files have incorrect permissions or ownership, invoke the commands `chmod <mode> <path>` and `chown <user>:<group> <path>`. 7. If rsyslog.log is missing on Manager, Global Manager, Edge or Public Cloud Gateway nodes, invoke the NSX CLI command `restart service syslog` which restarts the logging service and regenerates /var/log/rsyslog.log. 8. On Windows Physical Server nodes, ensure the log folder: C:\ProgramData\VMware\NSX\Logs exists. If not, re-install NSX on the Windows Physical Server nodes.
.vmwNSXsys.1.0.24.0.2All monitored log files have the correct file permissions and ownership and rsyslog.log exists on Manager, Global Manager, Edge or Public Cloud Gateway nodes. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.24.0.3Log messages to logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId) cannot be delivered possibly due to an unresolvable FQDN, an invalid TLS certificate or missing NSX appliance iptables rule. Action required: 1. Ensure that vmwNsxTDataCenterHostnameOrIPAddressWithPort is the correct hostname or IP address and port. 2. If the logging server is specified using a FQDN, ensure the FQDN is resolvable from the NSX appliance using the NSX CLI command `nslookup <fqdn>`. If not resolvable, verify the correct FQDN is specified and the network DNS server has the required entry for the FQDN. 3. If the logging server is configured to use TLS, verify the specified certificate is valid. For example, ensure the logging server is actually using the certificate or verify the certificate has not expired using the openssl command `openssl x509 -in <cert-file-path> -noout -dates`. 4. NSX appliances use iptables rules to explicitly allow outgoing traffic. Verify the iptables rule for the logging server is configured properly by invoking the NSX CLI command `verify logging-servers` which re-configures logging server iptables rules as needed. 5. If for any reason the logging server is misconfigured, it should be deleted using the NSX CLI `del logging-server <hostname-or-ip-address[:port]> proto <proto> level <level>` command and re-added with the correct configuration.
.vmwNSXsys.1.0.24.0.4Configuration for logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId) appear correct. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.22.0.1The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum supported count of vmwNsxTDataCenterMaxSupportedCapacityCount. Action required: Ensure that the number of NSX objects created is within the limits supported by NSX. If there are any unused objects, delete them using the respective NSX UI or API from the system. Consider increasing the form factor of all Manager nodes and/or Edge nodes. Note that the form factor of each node type should be the same. If not the same, the capacity limits for the lowest form factor deployed are used.
.vmwNSXsys.1.0.22.0.2The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount and is at or below the maximum supported count of vmwNsxTDataCenterMaxSupportedCapacityCount. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.22.0.3The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum capacity threshold of vmwNsxTDataCenterMaxCapacityThreshold%. Action required: Navigate to the capacity page in the NSX UI and review current usage versus threshold limits. If the current usage is expected, consider increasing the maximum threshold values. If the current usage is unexpected, review the network policies configured to decrease usage at or below the maximum threshold.
.vmwNSXsys.1.0.22.0.4The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount and is at or below the maximum capacity threshold of vmwNsxTDataCenterMaxCapacityThreshold%. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.22.0.5The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount which is above the minimum capacity threshold of vmwNsxTDataCenterMinCapacityThreshold%. Action required: Navigate to the capacity page in the NSX UI and review current usage versus threshold limits. If the current usage is expected, consider increasing the minimum threshold values. If the current usage is unexpected, review the network policies configured to decrease usage at or below the minimum threshold.
.vmwNSXsys.1.0.22.0.6The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has reached vmwNsxTDataCenterCapacityUsageCount and is at or below the minimum capacity threshold of vmwNsxTDataCenterMinCapacityThreshold%. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.3.0.7The trusted CA bundle vmwNsxTDataCenterEntityId was updated more than vmwNsxTDataCenterCABundleAgeThreshold days ago. Update for the trusted CA bundle is recommended. Action required: Ensure services that are currently using the trusted CA bundle are updated to use a recently-updated trusted CA bundle. Unless it is system-provided bundle, the bundle can be updated using the PUT /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API. Once the expired bundle is no longer in use, it should be deleted (if not system-provided) by invoking the DELETE /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
.vmwNSXsys.1.0.3.0.8The trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer in use. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.3.0.9The trusted CA bundle vmwNsxTDataCenterEntityId was updated more than vmwNsxTDataCenterCABundleAgeThreshold days ago. Update for the trusted CA bundle is suggested. Action required: Ensure services that are currently using the trusted CA bundle are updated to use a recently-updated trusted CA bundle. Unless it is system-provided bundle, the bundle can be updated using the PUT /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API. Once the expired bundle is no longer in use, it should be deleted (if not system-provided) by invoking the DELETE /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
.vmwNSXsys.1.0.3.0.10The trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer in use. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.3.0.1Certificate vmwNsxTDataCenterEntityId is approaching expiration. Action required: Ensure services that are currently using the certificate are updated to use a new, non-expiring certificate. Once the expiring certificate is no longer in use, it should be deleted by invoking the DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.
.vmwNSXsys.1.0.3.0.2The expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer approaching expiration. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.3.0.3Certificate vmwNsxTDataCenterEntityId has expired. Action required: Ensure services that are currently using the certificate are updated to use a new, non-expired certificate. Once the expired certificate is no longer in use, it should be deleted by invoking the DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API. If the expired certificate is used by NAPP Platform, the connection is broken between NSX and NAPP Platform. Check the NAPP Platform troubleshooting document to use a self-signed NAPP CA certificate for recovering the connection. For more information see: https://www.vmware.com/esx/support/askvmware/index.php?eventtype=certificates.certificate_expired
.vmwNSXsys.1.0.3.0.4The expired certificate vmwNsxTDataCenterEntityId has been removed or is no longer expired. Action required: None, receipt of this notification indicates event cleared.
.vmwNSXsys.1.0.3.0.5Certificate vmwNsxTDataCenterEntityId is about to expire. Action required: Ensure services that are currently using the certificate are updated to use a new, non-expiring certificate. Once the expiring certificate is no longer in use, it should be deleted by invoking the DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.