CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
Imported Objects
Objects
1,401 total| Object Name |
|---|
cucsComputeObjects MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.9 |
cucsComputeAutoconfigPolicyTable SEQUENCE OF CucsComputeAutoconfigPolicyEntry .1.3.6.1.4.1.9.9.719.1.9.1 |
cucsComputeAutoconfigPolicyEntry CucsComputeAutoconfigPolicyEntry .1.3.6.1.4.1.9.9.719.1.9.1.1 |
cucsComputeAutoconfigPolicyInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.1 |
cucsComputeAutoconfigPolicyDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.2 |
cucsComputeAutoconfigPolicyRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.3 |
cucsComputeAutoconfigPolicyDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.4 |
cucsComputeAutoconfigPolicyDstDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.5 |
cucsComputeAutoconfigPolicyIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.6 |
cucsComputeAutoconfigPolicyNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.7 |
cucsComputeAutoconfigPolicyQualifierro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.8 |
cucsComputeAutoconfigPolicySrcTemplNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.9 |
cucsComputeAutoconfigPolicyPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.1.1.10 |
cucsComputeAutoconfigPolicyPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.11 |
cucsComputeAutoconfigPolicyOperQualifierro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.1.1.12 |
cucsComputeBladeTable SEQUENCE OF CucsComputeBladeEntry .1.3.6.1.4.1.9.9.719.1.9.2 |
cucsComputeBladeEntry CucsComputeBladeEntry .1.3.6.1.4.1.9.9.719.1.9.2.1 |
cucsComputeBladeInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.1 |
cucsComputeBladeDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.2 |
cucsComputeBladeRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.3 |
cucsComputeBladeAdminPowerro CucsComputeAdminPowerState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.4 |
cucsComputeBladeAdminStatero CucsComputeAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.5 |
cucsComputeBladeAssignedToDnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.6 |
cucsComputeBladeAssociationro CucsComputeAssociation (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.7 |
cucsComputeBladeAvailabilityro CucsComputeAvailability (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.8 |
cucsComputeBladeAvailableMemoryro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.9 |
cucsComputeBladeChassisIdro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.10 |
cucsComputeBladeCheckPointro CucsComputeCheckPoint (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.11 |
cucsComputeBladeConnPathro CucsEquipmentConnectionStatus (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.12 |
cucsComputeBladeConnStatusro CucsEquipmentConnectionStatus (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.13 |
cucsComputeBladeDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.14 |
cucsComputeBladeDiscoveryro CucsComputeDiscovery (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.15 |
cucsComputeBladeFltAggrro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.9.2.1.16 |
cucsComputeBladeFsmDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.17 |
cucsComputeBladeFsmFlagsro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.18 |
cucsComputeBladeFsmPrevro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.19 |
cucsComputeBladeFsmProgrro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.20 |
cucsComputeBladeFsmRmtInvErrCodero Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.21 |
cucsComputeBladeFsmRmtInvErrDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.22 |
cucsComputeBladeFsmRmtInvRsltro CucsConditionRemoteInvRslt (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.23 |
cucsComputeBladeFsmStageDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.24 |
cucsComputeBladeFsmStampro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.9.2.1.25 |
cucsComputeBladeFsmStatusro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.26 |
cucsComputeBladeFsmTryro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.27 |
cucsComputeBladeIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.28 |
cucsComputeBladeLcro CucsComputeAdminTrigger (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.29 |
cucsComputeBladeLcTsro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.9.2.1.30 |
cucsComputeBladeManagingInstro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.31 |
cucsComputeBladeModelro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.32 |
cucsComputeBladeNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.33 |
cucsComputeBladeNumOfAdaptorsro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.34 |
cucsComputeBladeNumOfCoresro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.35 |
cucsComputeBladeNumOfCpusro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.36 |
cucsComputeBladeNumOfEthHostIfsro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.37 |
cucsComputeBladeNumOfFcHostIfsro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.38 |
cucsComputeBladeNumOfThreadsro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.39 |
cucsComputeBladeOperPowerro CucsEquipmentPowerState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.40 |
cucsComputeBladeOperQualifierro CucsComputeIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.41 |
cucsComputeBladeOperStatero CucsLsOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.42 |
cucsComputeBladeOperabilityro CucsEquipmentOperability (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.43 |
cucsComputeBladeOriginalUuidro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.44 |
cucsComputeBladePresencero CucsEquipmentSlotStatus (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.45 |
cucsComputeBladeRevisionro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.46 |
cucsComputeBladeSerialro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.47 |
cucsComputeBladeServerIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.48 |
cucsComputeBladeSlotIdro CucsComputeBladeSlotId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.49 |
cucsComputeBladeTotalMemoryro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.50 |
cucsComputeBladeUsrLblro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.51 |
cucsComputeBladeUuidro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.52 |
cucsComputeBladeVendorro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.53 |
cucsComputeBladeNumOfCoresEnabledro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.54 |
cucsComputeBladeLowVoltageMemoryro CucsComputePhysicalLowVoltageMemory (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.55 |
cucsComputeBladeMemorySpeedro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.56 |
cucsComputeBladeMfgTimero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.9.2.1.57 |
cucsComputeBladePartNumberro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.58 |
cucsComputeBladeVidro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.59 |
cucsComputeBladePolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.60 |
cucsComputeBladePolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.61 |
cucsComputeBladeLocalIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.62 |
cucsComputeBladeScaledModero CucsComputeMode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.63 |
cucsComputeBladeOperPwrTransSrcro CucsComputePowerTransitionSrc (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.65 |
cucsComputeBladeDiscoveryStatusro CucsEquipmentConnectionStatus (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.66 |
cucsComputeBladeNumOf40GAdaptorsWithOldFwro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.68 |
cucsComputeBladeNumOf40GAdaptorsWithUnknownFwro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.2.1.69 |
cucsComputeBladeAssetTagro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.70 |
cucsComputeBladeKmipFaultro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.9.2.1.71 |
cucsComputeBladeKmipFaultDescriptionro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.2.1.72 |
cucsComputeBladeDiscPolicyTable SEQUENCE OF CucsComputeBladeDiscPolicyEntry .1.3.6.1.4.1.9.9.719.1.9.3 |
cucsComputeBladeDiscPolicyEntry CucsComputeBladeDiscPolicyEntry .1.3.6.1.4.1.9.9.719.1.9.3.1 |
cucsComputeBladeDiscPolicyInstanceId CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.9.3.1.1 |
cucsComputeBladeDiscPolicyDnro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.9.3.1.2 |
cucsComputeBladeDiscPolicyRnro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.3.1.3 |
cucsComputeBladeDiscPolicyActionro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.3.1.4 |
cucsComputeBladeDiscPolicyDescrro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.3.1.5 |
cucsComputeBladeDiscPolicyIntIdro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.3.1.6 |
cucsComputeBladeDiscPolicyNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.3.1.7 |
cucsComputeBladeDiscPolicyQualifierro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.3.1.8 |
cucsComputeBladeDiscPolicyScrubPolicyNamero SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.9.3.1.9 |
cucsComputeBladeDiscPolicyPolicyLevelro Gauge32 .1.3.6.1.4.1.9.9.719.1.9.3.1.10 |
cucsComputeBladeDiscPolicyPolicyOwnerro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.9.3.1.11 |
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB Technical Reference Overview
The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB SNMP MIB module published by Cisco defines 1,401 managed OID objects, including 1,234 scalar/column metrics, 83 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.719.1.9. Key tabular structures include cucsComputeAutoconfigPolicyTable, cucsComputeBladeTable, cucsComputeBladeDiscPolicyTable, cucsComputeBladeEpTable, cucsComputeBladeFsmTable, cucsComputeBladeFsmStageTable.
Key OID Definitions in CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
.1.3.6.1.4.1.9.9.719.1.9MIB representation of the Cisco Unified Computing System COMPUTE management information model package
.1.3.6.1.4.1.9.9.719.1.9.1Cisco UCS compute:AutoconfigPolicy managed object table
.1.3.6.1.4.1.9.9.719.1.9.2Cisco UCS compute:Blade managed object table
.1.3.6.1.4.1.9.9.719.1.9.3Cisco UCS compute:BladeDiscPolicy managed object table
.1.3.6.1.4.1.9.9.719.1.9.66Cisco UCS compute:BladeEp managed object table
.1.3.6.1.4.1.9.9.719.1.9.48Cisco UCS compute:BladeFsm managed object table
.1.3.6.1.4.1.9.9.719.1.9.49Cisco UCS compute:BladeFsmStage managed object table
.1.3.6.1.4.1.9.9.719.1.9.4Cisco UCS compute:BladeFsmTask managed object table
.1.3.6.1.4.1.9.9.719.1.9.5Cisco UCS compute:BladeInheritPolicy managed object table
.1.3.6.1.4.1.9.9.719.1.9.6Cisco UCS compute:Board managed object table
.1.3.6.1.4.1.9.9.719.1.9.63Cisco UCS compute:BoardConnector managed object table
.1.3.6.1.4.1.9.9.719.1.9.7Cisco UCS compute:BoardController managed object table
.1.3.6.1.4.1.9.9.719.1.9.71Cisco UCS compute:Cartridge managed object table
.1.3.6.1.4.1.9.9.719.1.9.46Cisco UCS compute:ChassisConnPolicy managed object table
.1.3.6.1.4.1.9.9.719.1.9.8Cisco UCS compute:ChassisDiscPolicy managed object table
.1.3.6.1.4.1.9.9.719.1.9.9Cisco UCS compute:ChassisQual managed object table
.1.3.6.1.4.1.9.9.719.1.9.67Cisco UCS compute:ConstraintDef managed object table
.1.3.6.1.4.1.9.9.719.1.9.10Cisco UCS compute:Defaults managed object table
.1.3.6.1.4.1.9.9.719.1.9.64Cisco UCS compute:ExtBoard managed object table
.1.3.6.1.4.1.9.9.719.1.9.117Cisco UCS compute:FactoryResetOperation managed object table
.1.3.6.1.4.1.9.9.719.1.9.60Cisco UCS compute:FwSyncAck managed object table
.1.3.6.1.4.1.9.9.719.1.9.121Cisco UCS compute:GraphicsCardPolicy managed object table
.1.3.6.1.4.1.9.9.719.1.9.59Cisco UCS compute:HealthLedSensorAlarm managed object table
.1.3.6.1.4.1.9.9.719.1.9.122Cisco UCS compute:HwChangeDiscPolicy managed object table
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.
The CISCO-UNIFIED-COMPUTING-FIRMWARE-MIB enables SNMP-based monitoring and management of firmware versions, installation states, and upgrade status across Cisco UCS servers, fabric interconnects, and blade chassis. It provides granular visibility into the firmware lifecycle, including current revision levels, pending updates, and rollback capabilities for the entire unified computing infrastructure.