CERENT-GENERIC-MIB
This module provides the definitions for generic objects and notifications of Cisco ONS network device, ONS 15327, 15310.
Main OID:
cerentGenericMibModule.1.3.6.1.4.1.3607.1.10.40
982
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
982 total| Object Name |
|---|
cerentGenericMibModuleThis module provides the definitions for
generic objects and notifications of
Cisco ONS network device, ONS 15327, 15310. MODULE-IDENTITY .1.3.6.1.4.1.3607.1.10.40 |
cerentGenericObjectsAll the generic objects definitions are grouped
under this OBJECT IDENTIFIER .1.3.6.1.4.1.3607.2.10 |
cerentGenericCommonObjectsGroupThe group to combine all the Cisco OTBU common
objects OBJECT IDENTIFIER .1.3.6.1.4.1.3607.2.10.10 |
cerentGenericEnableNotificationThis variable indicates whether the system produces
notifications. A value=FALSE will prevent notifications
from being sent by this system.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.10.10 |
cerentGenericNodeTimeIndicates current local time as reflected by
the Cisco OTBU equipment. The format this scalar is
YYYYMMDDhhmmss{S/D}. E.g.,
20011103133453D means 1:34:53 PM PDT on 03/Nov/2001
19990614095436S means 9:54:36 AM PST on 14/Jun/1999.
If the last octet is S then the time is standard time.
Otherwise it is D to indicate it is daylight saving
time, if applicablero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.10.20 |
cerentGenericSentNotificationsA count of v1+v2 notifications sent out
by the agent. Resets to zero after
cold/warm start.ro Counter32 .1.3.6.1.4.1.3607.2.10.10.30 |
cerentGenericLastChangeTimeThe value of sysUpTime at the time
a conceptual row is created or deleted
in cerentGenericAlarmTablero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.10.40 |
cerentGenericMultishelfEnabledThis variable indicates whether the system is configured
in multi-shelf mode or single-shelf mode.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.10.50 |
cerentGenericGeneralGroupAnother class of objects found in
Cisco ONS 15327, 15310 OBJECT IDENTIFIER .1.3.6.1.4.1.3607.2.10.20 |
cerentGenericSoftwareVersionIndicates the version of software that is
used in Cisco ONS Network element,
ONS 15327, 15310. E.g., 2.2.03ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.20.10 |
cerentGenericAlarmGroupThe group that will represent all the
alarm info in the Cisco ONS network element,
ONS 15327, 15310 OBJECT IDENTIFIER .1.3.6.1.4.1.3607.2.10.30 |
cerentGenericAlarmCountTotal number of active alarms in the
Cisco ONS network element, ONS 15327, 15310.
This equals the total number of rows in
cerentGenericAlarmTable at any time.ro Unsigned32 .1.3.6.1.4.1.3607.2.10.30.10 |
cerentGenericAlarmTableThis table has all currently raised conditions
for the network node. A Condition is a fault or
status detected by hardware or software. SEQUENCE OF CerentGenericAlarmEntry .1.3.6.1.4.1.3607.2.10.30.20 |
cerentGenericAlarmEntryRow definition for cerentGenericAlarmTable CerentGenericAlarmEntry .1.3.6.1.4.1.3607.2.10.30.20.1 |
cerentGenericAlarmIndexUniquely identifies each entry in alarm table.
May not start with one and there may be some
missing numbers. Integer32 ( 1..2147483647 ) -- all +ve values .1.3.6.1.4.1.3607.2.10.30.20.1.10 |
cerentGenericAlarmObjectTypeThis will indicate what is the type
of the entity which raised this alarm.
( E.g., DS3, etherBridge, VT-TERM, etc )
The NMS is expected to use this value
to decide which table to poll for
further info about the alarmro CerentGenericEntityClass .1.3.6.1.4.1.3607.2.10.30.20.1.20 |
cerentGenericAlarmSlotNumberThis will indicate what is the slot
of the object which raised this alarm.
If not relevant to the alarm, will be
zero.ro Integer32 .1.3.6.1.4.1.3607.2.10.30.20.1.30 |
cerentGenericAlarmPortNumberThis will indicate what is the port
of the object which raised this alarm.ro CerentPortNumber (CERENT-TC) .1.3.6.1.4.1.3607.2.10.30.20.1.40 |
cerentGenericAlarmLineNumberThis will indicate what is the port
of the object which raised this alarm.
If not relevant to the alarm, will be
zero.ro Integer32 .1.3.6.1.4.1.3607.2.10.30.20.1.50 |
cerentGenericAlarmObjectIndexEvery alarm is raised by an object and
this object is an entry in a specific
table. This is the index of the object
in that table E.g., if the alarm is interface
related, this index is the index of the
interface in the interface table.ro Integer32 .1.3.6.1.4.1.3607.2.10.30.20.1.60 |
cerentGenericAlarmTypeIndicates what the exact nature of the
alarm. See the CerentGenericAlarmType TC
for mapping detailsro CerentGenericAlarmType .1.3.6.1.4.1.3607.2.10.30.20.1.70 |
cerentGenericAlarmStateSpecifies alarm severity and service
affecting status ( SA/NSA ). Only
{minor|major|critical}+{NA|NSA} alarms and
standing conditions will be represented here.
However, this mib object is included in each
trap dispatched and in the trap this object
can contain all the possible values of
CerentNotificationClass type.ro CerentNotificationClass (CERENT-TC) .1.3.6.1.4.1.3607.2.10.30.20.1.80 |
cerentGenericAlarmTimeStampThe value of sysUpTime when this entry was
created. This is accurate only upto a second.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.30.20.1.90 |
cerentGenericAlarmObjectNameTL1-style user-visible name which uniquely
identifies an object in the systemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.30.20.1.100 |
cerentGenericAlarmAdditionalInfoAdditional information for the alarm object.
In the current version of the MIB, this object
contains the following information :-
a) Provisioned description for alarms of type
'failureDetectedExternalToTheNE'.
This object would be a null string if no
additional information is specified.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.30.20.1.110 |
cerentGenericAlarmSeveritySpecifies severity of the alarm
being sent out.ro CerentAlarmSeverity (CERENT-TC) .1.3.6.1.4.1.3607.2.10.30.20.1.120 |
cerentGenericAlarmStatusRepresents if an alarm is currently raised or cleared.ro CerentAlarmStatus (CERENT-TC) .1.3.6.1.4.1.3607.2.10.30.20.1.130 |
cerentGenericAlarmServiceAffectingSpecifies whether the alarm that is being
sent out is Service Affecting (SA) or Non-
Service Affecting (NSA).ro CerentAlarmServiceAffecting (CERENT-TC) .1.3.6.1.4.1.3607.2.10.30.20.1.140 |
cerentGenericReportedAlarmCountNumber of alarms currently reported against Cisco
ONS platform. This equals the number of rows in
cerentGenericReportedAlarmTable.ro Unsigned32 .1.3.6.1.4.1.3607.2.10.30.30 |
cerentGenericReportedAlarmTableThis table has the list of alarms currently
reported for the Cisco ONS node. It does not
include any cleared alarms. The alarms in this
table are in compliance with Telcordia GR-253.
This means that if a network problem causes two
alarms, such a as loss of frame(LOF) and loss of
signal(LOS), only LOS alarm will be in this table
because it supersedes and replaces the LOF. SEQUENCE OF CerentGenericReportedAlarmEntry .1.3.6.1.4.1.3607.2.10.30.40 |
cerentGenericReportedAlarmEntryRow definition for cerentGenericReportedAlarmTable CerentGenericReportedAlarmEntry .1.3.6.1.4.1.3607.2.10.30.40.1 |
cerentGenericReportedAlarmIndexIdentifies each entry in ReportedAlarm table.
May not start with one and there may be some
missing numbers. Integer32 ( 1..2147483647 ) -- all +ve values .1.3.6.1.4.1.3607.2.10.30.40.1.10 |
cerentGenericReportedAlarmObjectTypeThis will indicate the type
of the entity which raised this alarm.
( E.g., DS3, etherBridge, VT-TERM, etc )
The NMS is expected to use this value
to decide which table to poll for
further info about the alarmro CerentGenericEntityClass .1.3.6.1.4.1.3607.2.10.30.40.1.20 |
cerentGenericReportedAlarmSlotNumberThis will indicate what is the slot
of the object which raised this alarm.
If not relevant to the alarm, will be
zero.ro Integer32 .1.3.6.1.4.1.3607.2.10.30.40.1.30 |
cerentGenericReportedAlarmPortNumberThis will indicate what is the port
of the object which raised this alarm.ro CerentPortNumber (CERENT-TC) .1.3.6.1.4.1.3607.2.10.30.40.1.40 |
cerentGenericReportedAlarmObjectIndexEvery alarm is raised by an object and
this object is an entry in a specific
table. This is the index of the object
in that table E.g., if the alarm is interface
related, this is the index of the
interface in the interface table.ro Integer32 .1.3.6.1.4.1.3607.2.10.30.40.1.50 |
cerentGenericReportedAlarmTypeIndicates the exact nature of the
alarm.ro CerentGenericAlarmType .1.3.6.1.4.1.3607.2.10.30.40.1.60 |
cerentGenericReportedAlarmTimeStampThe value of sysUpTime when this entry was
created. This is accurate only upto a second.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.30.40.1.70 |
cerentGenericReportedAlarmObjectNameTL1-style user-visible name which uniquely
identifies an object in the systemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.30.40.1.80 |
cerentGenericReportedAlarmAdditionalInfoAdditional information for the alarm object.
In the current version of the MIB, this object
contains the following information :-
a) Provisioned description for alarms of type
'failureDetectedExternalToTheNE'.
This object would be a null string if no
additional information is specified.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3607.2.10.30.40.1.90 |
cerentGenericReportedAlarmSeveritySpecifies severity of the alarm.ro CerentAlarmSeverity (CERENT-TC) .1.3.6.1.4.1.3607.2.10.30.40.1.100 |
cerentGenericReportedAlarmStatusRepresents if the alarm is currently raised
or cleared.ro CerentAlarmStatus (CERENT-TC) .1.3.6.1.4.1.3607.2.10.30.40.1.110 |
cerentGenericReportedAlarmServiceAffectingSpecifies whether the alarm that is being
sent out is Service Affecting (SA) or Non-
Service Affecting (NSA).ro CerentAlarmServiceAffecting (CERENT-TC) .1.3.6.1.4.1.3607.2.10.30.40.1.120 |
cerentGenericThresholdGroupThe group that will represent all the
threshold info in the Cisco ONS network element,
ONS 15327, 15310 OBJECT IDENTIFIER .1.3.6.1.4.1.3607.2.10.40 |
cerentGenericThresholdTableThis table holds all the provisioned
Thresholds.
This table is currently unimplemented. SEQUENCE OF CerentGenericThresholdEntry .1.3.6.1.4.1.3607.2.10.40.10 |
cerentGenericThresholdEntryRow definition for cerentGenericThresholdTable CerentGenericThresholdEntry .1.3.6.1.4.1.3607.2.10.40.10.1 |
cerentGenericThresholdIndexUniquely identifies each entry in Threshold table.
May not start with one and there will be some
missing numbers. Integer32 .1.3.6.1.4.1.3607.2.10.40.10.1.10 |
cerentGenericThresholdMonitorTypeThis object indicates the type of metric monitored.ro CerentMonitorType (CERENT-TC) .1.3.6.1.4.1.3607.2.10.40.10.1.20 |
cerentGenericThresholdLocationThis indicates if it near or far endro CerentLocation (CERENT-TC) .1.3.6.1.4.1.3607.2.10.40.10.1.30 |
cerentGenericThresholdPeriodThe sampling interval period is indicated herero CerentPeriod (CERENT-TC) .1.3.6.1.4.1.3607.2.10.40.10.1.40 |
cerentGenericThresholdSetValueThe value of this object will be threshold that was
provisioned by the NMSro Integer32 .1.3.6.1.4.1.3607.2.10.40.10.1.50 |
cerentGenericThresholdCurrentValueThe current value of the counter which
measures the metric.
This column will never be implemented as
these values are already accessible through
IETF MIB objects.ro Integer32 .1.3.6.1.4.1.3607.2.10.40.10.1.60 |
cerentGenericThresholdDetectTypeThe value of this object will be the detect type for the
threshold.ro Enumeration .1.3.6.1.4.1.3607.2.10.40.10.1.70 |
cerentGenericEventsPlace holder for all notifications
of Cisco ONS network device, ONS 15327, 15310 OBJECT IDENTIFIER .1.3.6.1.4.1.3607.2.20 |
cerentGenericV2EventsThe sub-identifier has to be zero, as part
of the interoperability agreement between
SNMPv1 and SNMPv2 worlds. OBJECT IDENTIFIER .1.3.6.1.4.1.3607.2.20.0 |
galarmUnknownalarm unknown NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1 |
galarmCutoffIsInManualModealarm cutoff is in manual mode NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.10 |
gfailureDetectedExternalToTheNEfailure detected External to the NE NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.20 |
gexternalErrorexternal error NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.30 |
gexcessiveSwitchingexcessive switching NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.40 |
gsdccTerminationFailureSDCC Termination failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.50 |
gincomingFailureConditionincoming failure condition NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.60 |
galarmIndicationSignalalarm indication signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.70 |
galarmIndicationSignalLinealarm indication signal LINE NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.80 |
galarmIndicationSignalPathalarm indication signal Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.90 |
galarmIndicationSignalVTalarm indication signal VT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.100 |
gapsChannelFailurechannel failure APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.110 |
gchannelByteFailureAPSchannel Byte failure APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.120 |
gchannelProtectionSwitchingChannelMatchFailureAPSchannel Protection Switching Channel Match failure APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.130 |
gchannelAutomaticProtectionSwitchModeMismatchAPSchannel Automatic Protection Switch Mode Mismatch APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.140 |
gfarEndProtectionLineFailurechannel far end protection line failure APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.150 |
ginconsistentAPSCodeInconsistent APS code NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.160 |
gimproperAPSCodeImproper APS code APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.170 |
gnodeIdMismatchNode Id Mismatch APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.180 |
gchannelDefaultKAPSDefault K APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.190 |
gconnectionLossConnection loss APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.200 |
gbipolarViolationbipolar Violation NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.210 |
gcarrierLossOnTheLANcarrier Loss on the LAN NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.220 |
gconcatenationErrorSTSconcatenation error STS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.230 |
gexcessCollisionsOnTheLANexcess collisions on the LAN NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.240 |
gfacilityFailurefacility critical alarm caused by DS3 facility failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.250 |
gfarEndAISfar end AIS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.260 |
gfarEndMultipleDS1LOSDetectedOnDS3far end Multiple DS1 LOS detected on DS3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.270 |
gfarEndDS1EqptFailNonServiceAffectingfar end DS1 eqpt fail non service affecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.280 |
gfarEndDS1EqptFailServiceAffectingfar end DS1 Eqpt fail service affecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.290 |
gfarEndSingleDS1LOSfar end Single DS1 LOS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.300 |
gfarEndDS3EqptFailNonServiceAffectingfar end DS3 Eqpt failure non service affecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.310 |
gfarEndDS3EqptFailServiceAffectingfar end DS3 Eqpt failure service affecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.320 |
gfarEndCommonEquipmentFailureNonServiceAffectingfar end common Eqpt failure non service affecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.330 |
gfarEndIDLEfar end IDLE NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.340 |
gfarEndLOSfar end LOS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.350 |
gfarEndLOFfar end LOF NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.360 |
gfarEndBlockErrorfar End Block Error NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.370 |
gds3IdleConditionidle Condition DS3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.380 |
glossOfFrameloss of Frame NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.390 |
glossOfPointerloss of Pointer NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.400 |
glossOfPointerPathloss of Pointer Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.410 |
glossOfPointerVTloss of Pointer VT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.420 |
glossOfSignalloss of Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.430 |
goutOfFrameout of Frame NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.440 |
gpathSelectorFailurepath Selector inability to swtich to a valid signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.450 |
gremoteAlarmIndicationremote Alarm Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.460 |
gremoteFailureIndicationremote Failure Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.470 |
gremoteFailureIndicationLineremote Failure Indication LINE NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.480 |
gremoteFailureIndicationPathremote Failure Indication Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.490 |
gremoteFailureIndicationVTremote Failure Indication VT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.500 |
gsignalDegradeSignal Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.510 |
gseverelyErroredFrameseverely Errored Frame NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.520 |
gsignalFailureSignal Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.530 |
gsignalLabelMismatchFailuresignal Label Mismatch Failures NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.540 |
gpayloadDefectIndicationPayload Defect Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.550 |
gpayloadDefectIndicationPathPayload Defect Indication - Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.560 |
gpayloadLabelMismatchPathPayload Label Mismatch - Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.570 |
gsignalLabelMismatchFailurePayloadLabelMismatchVTsignal Label Mismatch Failure Payload Label Mismatch VT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.580 |
gunequippedPathUnequipped - Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.590 |
gsignalLabelMismatchFailureUnequippedVTsignal Label Mismatch Failure Unequipped VT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.600 |
glossOfSynchronizationLoss of Synchronization NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.610 |
goutOfSynchronizationOut of Synchronization NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.620 |
gprimarySynchronizationReferenceFailurePrimary Synchronization Reference Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.630 |
gsecondarySynchronizationReferenceFailureSecondary Synchronization Reference Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.640 |
gthirdSynchronizationReferenceFailureThird Synchronization Reference Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.650 |
gfourthSynchronizationReferenceFailureFourth Synchronization Reference Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.660 |
gfifthSynchronizationReferenceFailureFifth Synchronization Reference Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.670 |
gsixthSynchronizationReferenceFailureSixth Synchronization Reference Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.680 |
gfailedToReceiveSynchronizationStatusMessagefailed to receive Synchronization Status Message NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.690 |
gsynchronizationStatusMessagesAreDisabledOnThisInterfacesynchronization Status Messages are disabled on this interface NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.700 |
gstratum1PrimaryReferenceSourceTraceableStratum1 Primary Reference Source Traceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.710 |
gsynchronizedTraceabilityUnknownsynchronized Traceability Unknown NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.720 |
gstratum2Traceablestratum 2 Traceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.730 |
gtransitNodeClockTraceabletransit Node clock Traceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.740 |
gstratum3ETraceablestratum 3E Traceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.750 |
gstratum3Traceablestratum 3 Traceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.760 |
gsonetMinimumClockTraceableMinimum clock Traceable - SONET NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.770 |
gstratum4Traceablestratum 4 Traceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.780 |
gdoNotUseForSynchronizationdo not Use for Synchronization NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.790 |
greservedForNetworkSynchronizationUsereserved for Network Synchronization Use NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.800 |
goutgoingFailureConditionoutgoing failure condition NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.810 |
gremoteDefectIndicationLineremote Defect Indication LINE NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.820 |
gremoteDefectIndicationPathremote Defect Indication Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.830 |
gfreeRunningSynchronizationModefree Running Synchronization mode NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.840 |
gholdoverSynchronizationModeholdover synchronization mode NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.850 |
gfastStartSynchronizationModefast Start synchronization mode NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.860 |
ginternalFaultinternal hardware fault or failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.870 |
ginternalErrorerror Internal to the NE Detected NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.880 |
ginternalMessageErrorinternal Message Error NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.890 |
gmismatchOfEquipmentAndAttributesmismatch of Equipment and Attributes NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.900 |
gwatchdogTimerTimeoutwatchdog Timer Timeout NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.910 |
gsoftwareFaultOrFailuresoftware Fault or failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.920 |
gsoftwareFaultDataIntegrityFaultsoftware Fault - Data integrity fault :
The newly added provisioning or hardware has
caused the database to grow beyond its limit.
That is, the newly added object(s) in the system
has(have) enough memory to exist onboard but
too large to be saved in the database. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.930 |
gprogramFailureprogram failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.940 |
gcontrolEquipmentFailurecontrol Equipment failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.950 |
gprimaryNonVolatileBackupMemoryFailurecontrol Equipment Primary non volatile Backup Memory failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.960 |
gsecondaryNonVolatileBackupMemoryFailurecontrol Equipment Secondary non volatile Backup Memory failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.970 |
gcontrolBusFailurecontrol Equipment Control Bus failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.980 |
gcontrolBus1Failurecontrol Equipment Control Bus 1 failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.990 |
gcontrolBus2Failurecontrol Equipment Control Bus 2 failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1000 |
gtccAToShelfSlot1DROP1CommunicationFailurecommunication failure Controller A to Shelf SLOT 1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1010 |
gtccAToShelfSlot2DROP2CommunicationFailurecommunication failure Controller A to Shelf SLOT 2 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1020 |
gtccAToShelfSlot3DROP3CommunicationFailurecommunication failure Controller A to Shelf SLOT 3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1030 |
gtccAToShelfSlot4DROP4CommunicationFailurecommunication failure Controller A to Shelf SLOT 4 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1040 |
gtccAToShelfSlot5TRUNK1CommunicationFailurecommunication failure Controller A to Shelf SLOT 5 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1050 |
gtccAToShelfSlot6TRUNK2CommunicationFailurecommunication failure Controller A to Shelf SLOT 6 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1060 |
gtccAToShelfSlot7TCCACommunicationFailurecommunication failure Controller A to Shelf SLOT 7 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1070 |
gtccAToShelfSlot8XCONACommunicationFailurecommunication failure Controller A to Shelf SLOT 8 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1080 |
gtccAToShelfSlot9AICCommunicationFailurecommunication failure Controller A to Shelf SLOT 9 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1090 |
gtccAToShelfSlot10XCONBCommunicationFailurecommunication failure Controller A to Shelf SLOT 10 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1100 |
gtccAToShelfSlot11TCCBCommunicationFailurecommunication failure Controller A to Shelf SLOT 11 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1110 |
gtccAToShelfSlot12TRUNK3CommunicationFailurecommunication failure Controller A to Shelf SLOT 12 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1120 |
gtccAToShelfSlot13TRUNK4CommunicationFailurecommunication failure Controller A to Shelf SLOT 13 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1130 |
gtccAToShelfSlot14DROP5CommunicationFailurecommunication failure Controller A to Shelf SLOT 14 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1140 |
gtccAToShelfSlot15DROP6CommunicationFailurecommunication failure Controller A to Shelf SLOT 15 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1150 |
gtccAToShelfSlot16DROP7CommunicationFailurecommunication failure Controller A to Shelf SLOT 16 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1160 |
gtccAToShelfSlot17DROP8CommunicationFailurecommunication failure Controller A to Shelf SLOT 17 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1170 |
gtccAToDCCAProcessorCommunicationFailurecommunication failure ControllerP A to ControllerJ A processor NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1180 |
gtccBToShelfSlot1DROP1CommunicationFailurecommunication failure Controller B to Shelf SLOT 1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1190 |
gtccBToShelfSlot2DROP2CommunicationFailurecommunication failure Controller B to Shelf SLOT 2 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1200 |
gtccBToShelfSlot3DROP3CommunicationFailurecommunication failure Controller B to Shelf SLOT 3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1210 |
gtccBToShelfSlot4DROP4CommunicationFailurecommunication failure Controller B to Shelf SLOT 4 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1220 |
gtccBToShelfSlot5TRUNK1CommunicationFailurecommunication failure Controller B to Shelf SLOT 5 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1230 |
gtccBToShelfSlot6TRUNK2CommunicationFailurecommunication failure Controller B to Shelf SLOT 6 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1240 |
gtccBToShelfSlot7TCCACommunicationFailurecommunication failure Controller B to Shelf SLOT 7 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1250 |
gtccBToShelfSlot8XCONACommunicationFailurecommunication failure Controller B to Shelf SLOT 8 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1260 |
gtccBToShelfSlot9AICCommunicationFailurecommunication failure Controller B to Shelf SLOT 9 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1270 |
gtccBToShelfSlot10XCONBCommunicationFailurecommunication failure Controller B to Shelf SLOT 10 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1280 |
gtccBToShelfSlot11TCCBCommunicationFailurecommunication failure Controller B to Shelf SLOT 11 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1290 |
gtccBToShelfSlot12TRUNK3CommunicationFailurecommunication failure Controller B to Shelf SLOT 12 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1300 |
gtccBToShelfSlot13TRUNK4CommunicationFailurecommunication failure Controller B to Shelf SLOT 13 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1310 |
gtccBToShelfSlot14DROP5CommunicationFailurecommunication failure Controller B to Shelf SLOT 14 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1320 |
gtccBToShelfSlot15DROP6CommunicationFailurecommunication failure Controller B to Shelf SLOT 15 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1330 |
gtccBToShelfSlot16DROP7CommunicationFailurecommunication failure Controller B to Shelf SLOT 16 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1340 |
gtccBToShelfSlot17DROP8CommunicationFailurecommunication failure Controller B to Shelf SLOT 17 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1350 |
gtccBToDCCBProcessorCommunicationFailurecommunication failure ControllerP B to ControllerJ A processor NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1360 |
gcontrolEquipmentControlCommunicationsEquipmentFailurecontrol Equipment Control Communications equipment failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1370 |
gcontrolProcessorFailurecontrol Equipment Control processor failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1380 |
gworkingMemoryFailurecontrol Equipment Working memory failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1390 |
ginterconnectionEquipmentFailureinterconnection Equipment failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1400 |
gpayloadBusFailureToIOSlot1XCONSlot8interconnection Equipment failure Payload Bus 1 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1410 |
gpayloadBusFailureToIOSlot2XCONSlot8interconnection Equipment failure Payload Bus 2 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1420 |
gpayloadBusFailureToIOSlot3XCONSlot8interconnection Equipment failure Payload Bus 3 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1430 |
gpayloadBusFailureToIOSlot4XCONSlot8interconnection Equipment failure Payload Bus 4 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1440 |
gpayloadBusFailureToIOSlot5XCONSlot8interconnection Equipment failure Payload Bus 5 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1450 |
gpayloadBusFailureToIOSlot6XCONSlot8interconnection Equipment failure Payload Bus 6 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1460 |
gpayloadBusFailureToIOSlot12XCONSlot8interconnection Equipment failure Payload Bus 7 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1470 |
gpayloadBusFailureToIOSlot13XCONSlot8interconnection Equipment failure Payload Bus 8 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1480 |
gpayloadBusFailureToIOSlot14XCONSlot8interconnection Equipment failure Payload Bus 9 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1490 |
gpayloadBusFailureToIOSlot15XCONSlot8interconnection Equipment failure Payload Bus 10 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1500 |
gpayloadBusFailureToIOSlot16XCONSlot8interconnection Equipment failure Payload Bus 11 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1510 |
gpayloadBusFailureToIOSlot17XCONSlot8interconnection Equipment failure Payload Bus 12 Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1520 |
gpayloadBusFailureToIOSlot1XCONSlot10interconnection Equipment failure Payload Bus 1 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1530 |
gpayloadBusFailureToIOSlot2XCONSlot10interconnection Equipment failure Payload Bus 2 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1540 |
gpayloadBusFailureToIOSlot3XCONSlot10interconnection Equipment failure Payload Bus 3 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1550 |
gpayloadBusFailureToIOSlot4XCONSlot10interconnection Equipment failure Payload Bus 4 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1560 |
gpayloadBusFailureToIOSlot5XCONSlot10interconnection Equipment failure Payload Bus 5 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1570 |
gpayloadBusFailureToIOSlot6XCONSlot10interconnection Equipment failure Payload Bus 6 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1580 |
gpayloadBusFailureToIOSlot12XCONSlot10interconnection Equipment failure Payload Bus 7 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1590 |
gpayloadBusFailureToIOSlot13XCONSlot10interconnection Equipment failure Payload Bus 8 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1600 |
gpayloadBusFailureToIOSlot14XCONSlot10interconnection Equipment failure Payload Bus 9 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1610 |
gpayloadBusFailureToIOSlot15XCONSlot10interconnection Equipment failure Payload Bus 10 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1620 |
gpayloadBusFailureToIOSlot16XCONSlot10interconnection Equipment failure Payload Bus 11 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1630 |
gpayloadBusFailureToIOSlot17XCONSlot10interconnection Equipment failure Payload Bus 12 Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1640 |
gtimeSlotInterchangeEquipmentFailureinterconnection Eqpt Time slot interchange eqpt failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1650 |
gequipmentFailureequipment failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1660 |
ghighTemperatureHigh Temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1670 |
ginvalidMACAddressequipment failure Invalid MAC Address NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1680 |
gboardFailureequipment failure Board Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1690 |
gdiagnosticFailureequipment failure Diagnostics Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1700 |
gmediumAccessControlFailureequipment failure Medium Access Control NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1710 |
gfacilityTerminationEquipmentFailurefacility Termination equipment failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1720 |
gautomaticLaserShutoffDueToHighTemperatureAutomatic Laser Shutoff Due To High Temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1730 |
gfailureToReleaseFromProtectionfailure To Release from protection NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1740 |
greceiverFailurefacility Termination equipment Receiver failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1750 |
gtransmitFailurefacility Termination equipment Transmit failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1760 |
gfacilityTerminationEquipmentReceiverMissingfacility Termination equipment Receiver missing NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1770 |
gfacilityTerminationEquipmentTransmitterMissingfacility Termination equipment Transmitter missing NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1780 |
gfailureToSwitchToProtectionfailure To Switch to protection NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1790 |
gfailureToSwitchToProtectionRingfailure To Switch to protection Ring NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1800 |
gfailureToSwitchToProtectionSpanfailure To Switch to protection Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1810 |
gfailureToSwitchToProtectionPathfailure to Switch to protection Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1820 |
gfanFailurefailure of cooling fan tray NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1830 |
gequipmentUnitPlugInequipment unit plug in NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1840 |
gnePowerFailureAtConnectorNE Power Failure At Connector NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1850 |
gfuseAlarmpower failure Fuse Alarm NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1860 |
gsynchronizationUnitFailuresynchronization unit failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1870 |
gsynchronizationSwitchingEquipmentFailuresynchronization switching Equipment failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1880 |
gequipmentUnitUnpluggedequipment unit un plug NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1890 |
gloopbackloop back NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1900 |
gds1LoopbackDueToFEACCommandloopback due to FEAC command DS1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1910 |
gloopbackCommandSentToFarEndDS1loopback Command sent to Far End DS1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1920 |
gds3LoopbackDueToFEACCommandloopback due to FEAC command DS3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1930 |
gds3LoopbackCommandSentToFarEndloopback Command sent to Far End DS3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1940 |
gds2LoopbackDueToFarEndCommandloopback due to Far End Command DS2 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1950 |
gds2LoopbackCommandSentToFarEndloopback Command sent to Far End DS2 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1960 |
gfacilityLoopbackloop back facility NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1970 |
gnetworkLoopbackloop back Network NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1980 |
gterminalLoopbackloop back Terminal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.1990 |
gmanuallyCausedAbnormalConditionmanually caused abnormal condition NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2000 |
gethernetBridgeIsNewRootOfSpanningTreenew Root discovered in bridged network NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2010 |
gethernetBridgeTopologyChangetopology change discovered in bridged network NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2020 |
gnormalConditionnormal condition NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2030 |
gembeddedOperationsChannelFailureLinkDownembedded Operations Channel failure link down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2040 |
gpeerStateMismatchpeer state mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2050 |
gproceduralErrorprocedural Error NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2060 |
gimproperRemovalImproper Removal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2070 |
gduplicateNodeIDDuplicate Node ID NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2080 |
gblsrOutOfSyncBLSR out of sync NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2090 |
gblsrMultiNodeTableUpdateCompletedBLSR tables resynchronized NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2100 |
gprotectionUnitNotAvailableprotection unit not available NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2110 |
gperformanceMonitorThresholdCrossingAlertperformance Monitor Threshold Crossing Alert NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2120 |
gprotectionSwitchoccurrence of a protection switching event NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2130 |
grecoveryOrServiceProtectionActionHasBeenInitiatedrecovery or service protection action has been initiated NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2140 |
gautomaticSystemResetautomatic system Reset NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2150 |
gautomaticUPSRSwitchCausedByAISautomatic UPSR switch caused by AIS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2160 |
gautomaticUPSRSwitchCausedByLOPautomatic UPSR switch caused by Lop NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2170 |
gautomaticUPSRSwitchCausedByUNEQautomatic UPSR switch caused by Uneq NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2180 |
gautomaticUPSRSwitchCausedByPDIautomatic UPSR switch caused by PDI NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2190 |
gautomaticUPSRSwitchCausedBySFBERautomatic UPSR switch caused by Sfber NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2200 |
gautomaticUPSRSwitchCausedBySDBERautomatic UPSR switch caused by Sdber NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2210 |
gcoldRestartcold Restart NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2220 |
gforcedSwitchBackToWorkingworking facility or eqpt forced switched to working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2230 |
gforcedSwitchBackToWorkingRingworking facility or eqpt forced switched to working Ring NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2240 |
gforcedSwitchBackToWorkingSpanworking facility or eqpt forced switched to working Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2250 |
gforcedSwitchToProtectionworking facility or eqpt forced switched protection unit NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2260 |
gforcedSwitchToProtectionRingworking facility or eqpt forced switched protection unit Ring NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2270 |
gforcedSwitchToProtectionSpanworking facility or eqpt forced switched protection unit Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2280 |
gworkingFacilityOrEquipmentForcedToSwitchToProtectionPathworking facility or eqpt forced switched protection unit Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2290 |
ginitializationInitiatedinitialization initiated NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2300 |
glockoutOfProtectionlockout of Protection NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2310 |
glockoutOfProtectionRinglockout of Protection Ring NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2320 |
glockoutOfProtectionSpanlockout of Protection Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2330 |
glockoutOfProtectionPathlockout of Protection Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2340 |
glockoutOfWorkinglockout of working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2350 |
glockoutOfWorkingRinglockout of working Ring NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2360 |
glockoutOfWorkingSpanlockout of working Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2370 |
gmanualSystemResetmanual system Reset NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2380 |
gmanualSwitchToInternalClockmanual switch to internal clock NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2390 |
gmanualSwitchToPrimaryReferencemanual Switch To Primary refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2400 |
gmanualSwitchToSecondReferencemanual Switch To Second reference NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2410 |
gmanualSwitchToThirdReferencemanual Switch To Third refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2420 |
gmanualSwitchToFourthReferencemanual Switch To Fourth refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2430 |
gmanualSwitchToFifthReferencemanual Switch To Fifth refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2440 |
gmanualSwitchToSixthReferencemanual Switch To Sixth refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2450 |
gmanualSwitchBackToWorkingmanualSwitch of working facility or eqpt to protection Ring NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2460 |
gmanualSwitchBackToWorkingRingmanualSwitch of working facility or eqpt to protection Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2470 |
gmanualSwitchBackToWorkingSpanmanualSwitch of working facility or eqpt to protection NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2480 |
gmanualSwitchToProtectionmanualSwitch of Working facility or eqpt to Protection unit NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2490 |
gmanualSwitchToProtectionRingworking facility or eqpt manualSwitch to Protection unit Ring NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2500 |
gmanualSwitchToProtectionSpanworking facility or eqpt manualSwitch to Protection unit Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2510 |
gmanualSwitchOfWorkingFacilityOrEquipmentToProtectionPathmanualSwitch of working facility or eqpt to Protection Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2520 |
gpowerfailRestartPowerfail Restart NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2530 |
gringIsSquelchingTrafficring is squelching traffic NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2540 |
gsoftwareDownloadInProgresssoftware download in progress NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2550 |
gswitchToInternalClockSwitch To Internal clock NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2560 |
gswitchToPrimaryReferenceSwitch To Primary refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2570 |
gswitchToSecondReferenceSwitch To Second refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2580 |
gswitchToThirdReferenceSwitch To Third refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2590 |
gswitchToFourthReferenceSwitch To Fourth refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2600 |
gswitchToFifthReferenceSwitch To Fifth refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2610 |
gswitchToSixthReferenceSwitch To Sixth refernce NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2620 |
gsystemRebootsystem reboot NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2630 |
gswitchedBackToWorkingSwitched Back To Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2640 |
gswitchedToProtectionSwitched To Protection NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2650 |
gwarmRestartwarm Restart NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2660 |
gringIsInWaitToRestoreStateRing is in Wait To Restore state NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2670 |
gmanualSwitchRequestManual Switch Request NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2680 |
gforcedSwitchRequestForced Switch Request NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2690 |
glockoutSwitchRequestLockout Switch Request NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2700 |
grmonHistoriesAndAlarmsResetRebootRMON histories and alarms have been reset due to chipset reboot NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2710 |
grmonThresholdCrossingAlarmCrossing of Falling/Rising Threshold detected NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2720 |
galarmsSuppressedByUserCommandAlarms Suppressed By User Command NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2730 |
galarmsSuppressedForMaintenanceAlarms Suppressed For Maintenance NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2740 |
gswitchingMatrixModuleFailureSwitching Matrix Module Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2750 |
glanConnectionPolarityReversedLan Connection Polarity Reversed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2760 |
gautonomousPMReportMessageInhibitedAutonomous Performance Monitoring Report Message Inhibited NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2780 |
gioSlotToXCONCommunicationFailureIO Slot To XCON Communication Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2790 |
gstsPathTraceIdentifierMismatchSTS path trace identifier mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2800 |
gnePowerFailureAtConnectorANE power failure at connector A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2810 |
gnePowerFailureAtConnectorBNE power failure at connector B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2820 |
gfreeMemoryOnCardVeryLowFree memory on the card is very low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2830 |
gfreeMemoryOnCardNearZeroFree memory on the card is near zero NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2840 |
gexerciseRequestOnRingExercise Ring. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2850 |
gexerciseRequestOnSpanExercise Span. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2860 |
gsquelchingPathSquelching Path: NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2870 |
gextraTrafficPreemptedExtra Traffic Preempted. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2880 |
gfarEndLockoutOfWorkingRingFar End Lockout of working - Ring. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2890 |
gfarEndLockoutOfWorkingSpanFar End Lockout of working - Span. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2900 |
gfarEndLockoutOfProtectionRingFar End Lockout of Protection - Ring. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2910 |
gfarEndLockoutOfProtectionAllSpansFar End Lockout of Protection - All Spans. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2920 |
gfarEndWorkingFacilityForcedToSwitchToProtectionRingFar End Working facility forced to switch to protection unit - Ring. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2930 |
gfarEndWorkingFacilityForcedToSwitchToProtectionSpanFar End Working facility forced to switch to protection unit - Span. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2940 |
gfarEndManualSwitchOfWorkingFacilityToProtectionRingFar End Manual Switch of Working facility to Protection unit - Ring. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2950 |
gfarEndManualSwitchOfWorkingFacilityToProtectionSpanFar End Manual Switch of Working facility to Protection unit - Span. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2960 |
gfarEndExercisingRingFar End Exercise Ring. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2970 |
gfarEndExercisingSpanFar End Exercise Span. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2980 |
gfarEndBERThresholdPassedForSignalFailureRingFar End BER threshold passed for Signal Failure - Ring. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.2990 |
gfarEndBERThresholdPassedForSignalFailureSpanFar End BER threshold passed for Signal Failure - Span. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3000 |
gfarEndBERThresholdPassedForSignalDegradeRingFar End BER threshold passed for Signal Degrade - Ring. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3010 |
gfarEndBERThresholdPassedForSignalDegradeSpanFar End BER threshold passed for Signal Degrade - Span. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3020 |
gapsChannelFarEndProtectionLineSignalDegradeAPS Channel - Far End Protection Line Signal Degrade. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3030 |
gringSwitchIsActiveOnTheEastSideRing Switch is active on the East Side. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3040 |
gringSwitchIsActiveOnTheWestSideRing Switch is active on the West Side. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3050 |
gspanSwitchIsActiveOnTheEastSideSpan Switch is active on the East Side. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3060 |
gspanSwitchIsActiveOnTheWestSideSpan Switch is active on the West Side. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3070 |
guniDirectionalFullPassThroughIsActiveUni-directional Full Pass Through is active. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3080 |
gbiDirectionalFullPassThroughIsActiveBi-directional Full Pass Through is active. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3090 |
gkBytesPassThroughIsActiveK Bytes Pass Through is active. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3100 |
gringIsSegmentedRing is Segmented. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3110 |
gringTopologyIsUnderConstructionRing Topology is under construction. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3120 |
glockoutOfProtectionAllSpansLockout of Protection - All Spans. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3130 |
gfarEndOfFiberIsProvisionedWithDifferentRingIDFar end of fiber is provisioned with different ring ID NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3140 |
gbothEndsOfFiberProvisionedAsEastOrBothAsWestBoth ends of fiber provisioned as East, or both as West NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3150 |
gsecurityInvalidLoginUsernameSeeAuditTrailSecurity: Invalid Login Username - See Audit Trail NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3160 |
gautonomousMessagesInhibitedAutonomous messages inhibited NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3170 |
gtrafficStormOnLANLANTemporarilyDisabledTraffic storm on LAN. LAN temporarily disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3180 |
greptdbchgMessagesInhibitedREPT^DBCHG messages of TL1 inhibited NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3190 |
gsecurityUserIDHasExpiredSecurity: user ID has expired NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3200 |
gpartialFanFailurePartial Fan Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3210 |
gforcedSwitchRequestOnRingForce switch request on Ring NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3220 |
gforcedSwitchRequestOnSpanForce switch request on Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3230 |
glockoutSwitchRequestOnRingLockout switch request on Ring NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3240 |
glockoutSwitchRequestOnSpanLockout switch request on Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3250 |
gmanualSwitchRequestOnRingManual switch request on Ring NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3260 |
gmanualSwitchRequestOnSpanManual switch request on Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3270 |
gcommunicationFailurePeerToPeerSlotControlBusAPeer to Peer Slot communication failure - Control Bus A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3280 |
gcommunicationFailurePeerToPeerSlotControlBusBPeer to Peer Slot communication failure - Control Bus B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3290 |
gcontrollerAToShelfSlotCommunicationFailureController A to shelf slot communication failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3300 |
gcontrollerBToShelfSlotCommunicationFailureController B to shelf slot communication failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3310 |
ginterconnectionEquipmentFailureWorkingPayloadBusInterconnection Equipment Failure - Working Payload Bus NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3320 |
ginterconnectionEquipmentFailureProtectPayloadBusInterconnection Equipment Failure - Protect Payload Bus NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3330 |
ginhibitSwitchToProtectRequestOnEquipmentInhibit Switch to Protect Request on equipment NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3340 |
ginhibitSwitchToWorkingRequestOnEquipmentInhibit Switch to Working Request on equipment NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3350 |
gberThresholdExceededForSignalDegradeLineBER Threshold exceeded for Signal Degrade - Line NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3360 |
gberThresholdExceededForSignalDegradePathBER Threshold exceeded for Signal Degrade - Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3370 |
gberThresholdExceededForSignalFailureLineBER Threshold Exceeded For Signal Failure - Line NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3380 |
gberThresholdExceededForSignalFailurePathBER Threshold Exceeded For Signal Failure - Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3390 |
gexercisingRingSuccessfullyExercising Ring Successfully NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3400 |
gexercisingSpanSuccessfullyExercising Span Successfully NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3410 |
gspanIsInWaitToRestoreStateSpan is in Wait To Restore state NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3420 |
gexerciseRequestOnRingFailedExercise Ring Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3430 |
gexerciseRequestOnSpanFailedExercise Span Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3440 |
gfarEndLockoutOfProtectionSpanFar end Lockout of Protection Channel - Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3450 |
gmanufacturingDataMemoryEEPROMFailureManufacturing EEPROM Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3460 |
greplaceableEquipmentOrUnitIsMissingReplaceable Equipment/Unit Is Missing NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3470 |
gsoftwareDownloadFailedSoftware Download Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3480 |
gextraTrafficPCADroppedExtra Traffic Dropped NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3490 |
getherTxOversubscribedpkt loss due to oversubscribed xmit NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3500 |
getherRxOverSubscribedpkt loss due to oversubscribed rcv NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3510 |
getherTxExcessFlowCtrlexcessive ethernet flow ctl xmited NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3520 |
getherRxExcessFlowCtrlexcessive ethernet flow ctl recvd NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3530 |
gtransportLayerFailuretransport layer failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3540 |
getherTxUnderrunEther hdge internal fifo underrun NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3550 |
gsynchronizationReferenceFrequencyOutOfBoundsSynchronization reference frequency out of bounds. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3560 |
gntpOrSntpHostFailureNTP/SNTP Host Failure. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3570 |
gpeerCardNotRespondingPeer Card Not Responding NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3580 |
galarmsAndEventsSuppressedForThisObjectAlarms and events suppressed for this object NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3590 |
gds3FrameFormatMismatchDS3 Frame Format Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3600 |
gwaitToRestoreWait To Restore NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3610 |
gextremeHighVoltBatteryAExtreme High Volt Battery A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3620 |
gextremeLowVoltBatteryAExtreme Low Volt Battery A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3630 |
gextremeHighVoltBatteryBExtreme High Volt Battery B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3640 |
gextremeLowVoltBatteryBExtreme Low Volt Battery B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3650 |
giosConfigCopyFailedIOS config copy failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3660 |
giosConfigCopyInProgressIOS config copy in progress NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3670 |
giosConfigCopySuccessIOS Config Copy Success NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3680 |
gsignalingUnableToSetupCircuitSignaling Unable to setup circuit NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3710 |
gerrorInStartupConfigError in Startup Config NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3712 |
gnoStartupConfigNo Startup Config NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3714 |
gneedToSaveRunningConfigNeed to Save Running Config NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3716 |
ginvalidAlarmInvalid Alarm NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3718 |
grsvpHelloFSMToNeighborDownRSVP Hello FSM to Neighbor down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3720 |
gsecurityInvalidLoginUsernameSecurity: Invalid Login - Username - See Audit Log NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3722 |
gdatabaseBackupFailedDatabase Backup Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3724 |
gdatabaseRestoreFailedDatabase Restore Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3726 |
glmpHelloFSMToControlChannelDownLMP Hello FSM to Control Channel down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3730 |
glmpNeighborDiscoveryHasFailedLMP Neighbor Discovery has failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3740 |
gunauthorizedIncomingSignalingRequestUnauthorized incoming signaling request NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3750 |
gauditLog80PercentFullAudit Log 80 Percent Full NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3760 |
gmoduleCommunicationFailureModule Communication Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3762 |
gauditLog100PercentFullOldestRecordsWillBeLostAudit Log 100 Percent Full - Oldest records will be lost NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3764 |
gstandbyDatabaseOutOfSyncStandby Database Out of Sync NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3766 |
gredundantPowerCapabilityLostRedundant Power Capability Lost NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3768 |
gforcedSwitchToPrimaryReferenceForced Switch To Primary Reference NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3770 |
gforcedSwitchToSecondReferenceForced Switch To Second Reference NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3780 |
gforcedSwitchToThirdReferenceForced Switch To Third Reference NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3790 |
gforcedSwitchToInternalClockForced Switch To Internal Clock NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3800 |
gindustrialHighTemperatureIndustrial High Temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3805 |
gimproperMatrixEquipmentInsertedImproper matrix equipment inserted NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3810 |
geqptProblemOnCarrierOrPIMEQPT problem on Carrier or PIM NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3820 |
geqptProblemOnPIMOrPPMEQPT problem on PIM or PPM NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.3830 |
gtimSectionTraceIdentifierMismatchFailureTIM Section - Trace Identifier Mismatch Failure. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4000 |
gaisMultiplexSectionAlarmIndicationSignalSDH Multiplex Section - Alarm Indication Signal. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4010 |
grdiMultiplexSectionRemoteDefectOrAlarmIndicationSDH Multiplex Section - Remote Defect Indication. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4020 |
gtimHighOrderTraceIdentifierMismatchFailureSDH High Order - Trace Identifier Mismatch. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4030 |
gaisAdministrationUnitAlarmIndicationSignalSDH Administration Unit - Alarm Indication Signal. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4040 |
glopAdministrationUnitLossOfPointerSDH Administration Unit - Loss of Pointer. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4050 |
gslmfUnequippedHighOrderPathUnequippedSDH SLMF High Order - Unequipped Path. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4060 |
gslmfPLMHighOrderPathLabelMismatchSDH SLMF High Order - Path Label Mismatch. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4070 |
grdiHighOrderRemoteDefectOrAlarmIndicationSDH High Order - Remote Defect Indication. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4080 |
glopTributaryUnitLossOfPointerSDH Tributary Unit - Loss of Pointer. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4090 |
gaisTributaryUnitAlarmIndicationSignalSDH Tributary Unit - Alarm Indication Signal. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4100 |
gslmfUnequippedLowOrderPathUnequippedSDH Low Order - SLMF Unequipped Path. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4110 |
gslmfPLMLowOrderPathLabelMismatchSDH Low Order - SLMF Path Label Mismatch. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4120 |
gtimLowOrderTraceIdentifierMismatchFailureSDH Low Order - Trace Identifier Mismatch. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4130 |
grfiLowOrderRemoteFailureOrAlarmIndicationSDH Low Order - Remote Failure Indication. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4140 |
gg811PrimaryReferenceClockTraceableG811 - Primary Reference Clock traceable. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4150 |
gg812TransitNodeClockTraceableG812 - Transit Node Clock traceable. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4160 |
gg812LocalNodeClockTraceableG812 - Local Node Clock traceable. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4170 |
gg813SynchronousEquipmentTimingSourceTraceableG813 - Synchronous Equipment Timing Source traceable. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4180 |
ge1LoopbackDueToFEACCommandloopback due to FEAC Command E1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4190 |
ge1LoopbackCommandSentToFarEndloopback Command sent to Far End E1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4200 |
ge3LoopbackDueToFEACCommandloopback due to FEAC Command E3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4210 |
gfarEndMultipleE1LOSDetectedOnE3far end Multiple E1 LOS detected on E3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4220 |
gfarEndE1EqptFailNonServiceAffectingfar end E1 eqpt fail non service affecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4230 |
gfarEndE1EqptFailServiceAffectingfar end E1 eqpt fail service affecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4240 |
gfarEndSingleE1LOSfar end Single E1 LOS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4250 |
gfarEndE3EqptFailServiceAffectingfar end E3 eqpt fail service affecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4260 |
ge3LoopbackCommandSentToFarEndloopback Command sent to Far End E3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4270 |
gfarEndE3EqptFailNonServiceAffectingfar end E3 eqpt fail non service affecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4280 |
glowVoltBatteryALow Volt - Battery A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4290 |
ghighVoltBatteryAHigh Volt - Battery A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4300 |
glowVoltBatteryBLow Volt - Battery B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4310 |
ghighVoltBatteryBHigh Volt - Battery B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4320 |
gmsspRingOutOfSyncMS-SP ring out of sync NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4330 |
gmsspMultiNodeTableUpdateCompletedMS-SP ring tables resynchronized NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4340 |
gautomaticSNCPSwitchCausedByAISautomatic SNCP switch caused by AIS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4350 |
gautomaticSNCPSwitchCausedByLOPautomatic SNCP switch caused by Lop NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4360 |
gautomaticSNCPSwitchCausedByUNEQautomatic SNCP switch caused by Uneq NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4370 |
gautomaticSNCPSwitchCausedByPDIautomatic SNCP switch caused by PDI NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4380 |
gautomaticSNCPSwitchCausedBySFBERautomatic SNCP switch caused by Sfber NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4390 |
gautomaticSNCPSwitchCausedBySDBERautomatic SNCP switch caused by Sdber NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4400 |
gstmConcatenationErrorconcatenation error STM NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4410 |
ge3IdleConditionidle Condition E3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4420 |
gchannelMSSPInconsistentAPSCodechannel MSSP inconsistent APS code NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4430 |
gchannelMSSPImproperAPSCodeAPSchannel MSSP Improper APS code APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4440 |
gchannelMSSPNodeIdMismatchAPSchannel MSSP Node Id Mismatch APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4450 |
gchannelMSSPDefaultKAPSchannel MSSP Default K APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4460 |
gchannelMSSPConnectionLossAPSchannel MSSP Connection loss APS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4470 |
gminimumClockTraceableSDHSDH Minimum clock Traceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4480 |
glineIsInWaitToRestoreStateSDHSDH line is in Wait To Restore state NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4490 |
gberThresholdExceededForSignalDegradeHighOrderBER Threshold exceeded for Signal Degrade - High Order NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4500 |
gberThresholdExceededForSignalFailureHighOrderBER Threshold exceeded for Signal Failure - High Order NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4510 |
gberThresholdExceededForSignalDegradeLowOrderBER Threshold exceeded for Signal Degrade - Low Order NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4520 |
gberThresholdExceededForSignalFailureLowOrderBER Threshold exceeded for Signal Failure - Low Order NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4530 |
gfailureToSwitchToProtectionHighOrderPathFailure To Switch To Protection - High Order Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4540 |
gfailureToSwitchToProtectionLowOrderPathFailure To Switch To Protection - Low Order Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4550 |
glofAdministrationUnitLossOfMultiFrameSDH Administration Unit Loss of Multiframe. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4560 |
gsdhSpanIsInWaitToRestoreStateSDH span is in Wait To Restore state NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4570 |
ga8b10bOutOfSync8B10B Out of Sync NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4755 |
godukPMAlarmIndicationSignalODUk: Alarm Indication Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4760 |
gotukAlarmIndicationSignalOTUk: Alarm Indication Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4765 |
gotukSMBackwardDefectIndicationOTUk: Backward Defect Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4770 |
gfecUncorrectedWordFEC Uncorrected Word NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4780 |
ggccTerminationFailureGCC Termination Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4785 |
gotukIncomingAlignmentErrorOTUk: Incoming Alignment Error NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4790 |
godukLockedDefectPMODUk: Locked Defect PM NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4795 |
glossOfMultiFrameLoss of Multi-Frame NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4800 |
godukOpenConnectionIndicationODUk: Open Connection Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4805 |
gpayloadTypeIdentifierMismatchPayload Type Identifier Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4810 |
godukTrailTraceIdentifierMismatchODUk: Trail Trace Identifier Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4815 |
gotukTrailTraceIdentifierMismatchOTUk: Trail Trace Identifier Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4820 |
gequipmentHighLaserBiasEquipment High Laser Bias NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4825 |
gequipmentHighLaserTempEquipment High Laser Temp NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4830 |
gequipmentHighLaserPeltierEquipment High Laser Peltier NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4835 |
gfacilityHighRxPowerFacility High Rx power NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4840 |
gequipmentHighTxPowerEquipment High Tx power NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4845 |
gequipmentHighTransceiverVoltageEquipment High Transceiver voltage NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4850 |
gequipmentLowLaserBiasEquipment Low Laser Bias NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4855 |
gequipmentLowLaserTempEquipment Low Laser Temp NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4860 |
gequipmentLowLaserPeltierEquipment Low Laser Peltier NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4865 |
gfacilityLowRxPowerFacility Low Rx power NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4870 |
gequipmentLowTxPowerEquipment Low Tx power NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4875 |
gequipmentLowTransceiverVoltageEquipment Low Transceiver voltage NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4880 |
gequipmentRxLockedEquipment Rx Locked NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4885 |
gequipmentSquelchedEquipment Squelched NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4890 |
gequipmentTxLockedEquipment Tx Locked NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4895 |
gotukSignalFailureOTUK Signal Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4900 |
godukSignalFailureODUK Signal Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4905 |
gotukSignalDegradeOTUK Signal Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4910 |
godukSignalDegradeODUK Signal Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4915 |
gpluggablePortMissingPluggable Port missing NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4920 |
gpluggablePortRateMismatchPluggable Port rate mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4925 |
gpluggablePortSecurityCodeMismatchPluggable Port security code mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4930 |
gtciNotSelectedTci not selected NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4935 |
gtci1ClockFailureTci 1 Clock Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4940 |
godukPMBackwardDefectIndicationODUk: PM Backward Defect Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4945 |
godukTCM1BackwardDefectIndicationODUk: TCM1 Backward Defect Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4950 |
godukTCM2BackwardDefectIndicationODUk: TCM2 Backward Defect Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4955 |
gequipmentHighRxTemperatureEquipment High Rx temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4960 |
gequipmentLowRxTemperatureEquipment Low Rx temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4965 |
gtci2ClockFailureTci 2 Clock Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4970 |
gequipmentWavelengthMismatchEquipment Wavelength Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4975 |
gdspCommunicationFailureDSP Communication Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4980 |
gdspFailureDSP Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.4985 |
glaserApproachingEndOfLifeLaser Approaching End of Life NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5000 |
gcrossconnectLoopbackCross-connect Loopback NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5010 |
gadminLogoutOfUserAdmin Logout of User NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5020 |
guserLockedOutUser Locked Out NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5030 |
gadminLockoutOfUserAdmin Lockout of User NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5040 |
gadminLockoutClearAdmin Lockout Clear NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5050 |
ginvalidLoginUsernameInvalid Login: Username NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5060 |
gsecurityInvalidLoginPasswordInvalid Login: Password NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5070 |
gsecurityInvalidLoginLockedOutInvalid Login: Locked Out NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5080 |
gsecurityInvalidLoginAlreadyLoggedOnInvalid Login: Already Logged On NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5090 |
gloginOfUserLogin of User NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5100 |
gautomaticLogoutOfIdleUserAutomatic Logout of IdleUser NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5110 |
glogoutOfUserLogout of User NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5120 |
genhancedRemoteFailureIndicationPathServerEnhanced Remote Failure Indication - Path - Server NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5200 |
genhancedRemoteFailureIndicationPathConnectivityEnhanced Remote Failure Indication - Path - Connectivity NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5210 |
genhancedRemoteFailureIndicationPathPayloadEnhanced Remote Failure Indication - Path - Payload NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5220 |
gfirewallHasBeenDisabledFirewall Has Been Disabled NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5230 |
gsecurityIntrusionDetPwdSecurity Intrusion - Incorrect Password NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5240 |
gsecurityIntrusionDetUserSecurity Intrusion - Incorrect Username NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5250 |
gconnectionEquipmentMismatchConnection Equipment Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5260 |
gdisableInactiveUserDisable Inactive User NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5270 |
gdisableInactiveClearDisable Inactive Clear NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5280 |
gbatteryFailureBattery Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5290 |
gextremeHighVoltExtreme High Volt NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5300 |
gextremeLowVoltExtreme Low Volt NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5310 |
ghighVoltHigh Volt NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5320 |
glowVoltLow Volt NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5330 |
gsuspendUserSuspend User NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5340 |
gsuspendUserClearSuspend User Clear NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5350 |
glineDccTerminationFailureLine DCC Termination Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5360 |
gmultiplexSectionDccTerminationFailureMultiplex Section DCC Termination Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5370 |
ggigaBitEthernetOutOfSyncGigaBit Ethernet Out of Sync NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5380 |
gsequenceMismatchSequence Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5390 |
glossOfAlignmentLoss of Alignment NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5400 |
goutOfUseByAdministrativeCommandOut of Use - Administrative Command NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5410 |
goutOfUseTransportFailureOut of Use - Transport Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5420 |
gvcatGroupDownVCAT Group Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5430 |
gvcatGroupDegradedVCAT Group Degraded NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5440 |
gvcatGroupIncompleteVCAT Group Incomplete NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5450 |
galarmIndicationSignalInTXAlarm Indication Signal in TX NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5460 |
gremoteAlarmIndicationInTXRemote Alarm Indication in TX NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5470 |
gkByteAPSChannelFailureKbyte Channel Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5480 |
gapsInvalidModeAPS Invalid Mode NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5490 |
gipAddressAlreadyInUseWithinTheSameDccAreaIP address already in use within the same DCC Area NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5500 |
gnodeNameInUseWithinTheSameDccAreaNode name already in use within the same DCC Area NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5510 |
grearPanelEthernetLinkRemovedRear Panel Ethernet Link Removed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5520 |
gmanualSwitchToProtectResultedInNoTrafficSwitchManual Switch To Protect Resulted in No Traffic Switch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5530 |
gmanualSwitchBackToWorkingResultedInNoTrafficSwitchManual Switch Back To Working Resulted in No Traffic Switch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5540 |
gforcedSwitchToProtectResultedInNoTrafficSwitchForced Switch To Protection Resulted in No Traffic Switch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5550 |
gforcedSwitchBackToWorkingResultedInNoTrafficSwitchForced Switch Back To Working Resulted in No Traffic Switch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5560 |
gduplicateSerialNumberDetectedOnAPluggableEntityDuplicate Serial number detected on a pluggable entity NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5570 |
glossOfSignalForOpticalChannelIncoming Payload Signal Absent NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5600 |
gencapsulationMismatchPathEncapsulation Type Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5610 |
gencapsulationMismatchVTEncapsulation Mismatch - VT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5620 |
gencapsulationMismatchHighOrderPathEncapsulation Mismatch High Order - Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5630 |
gencapsulationMismatchLowOrderPathEncapsulation Mismatch Low Order - Path NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5640 |
ggfpUserPayloadMismatchGFP User Payload Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5650 |
ggfpFibreChannelDistanceExtensionMismatchGFP Fibre Channel Distance Extension Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5660 |
ggfpFibreChannelDistanceExtensionBufferStarvationGFP Fibre Channel Distance Extension Buffer Starvation NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5670 |
ggfpFibreChannelDistanceExtensionCreditStarvationFibre Channel Distance Extension Credit Starvation NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5680 |
gautomaticWdmAnsFinishedAutomatic WDM ANS Finished NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5690 |
ggfpClientSignalFailDetectedGFP Client Signal Fail Detected NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5700 |
ggfpLossOfFrameDelineationGFP Loss of Frame Delineation NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5710 |
ggfpExtensionHeaderMismatchGFP Extension Header Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5730 |
gincomingOverheadSignalAbsentLoss of Signal for Overhead NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5740 |
gopticalSafetyRemoteInterlockOnOptical Safety Remote Interlock On NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5750 |
gautomaticPowerControlCorrectionSkippedAutomatic Power Control Correction Skipped NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5770 |
gapcCannotSetValueDueToRangeLimitsAPC cannot set value due to range limits NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5780 |
glcasVcgMemberTxSideInAddStateLCAS VCG Member Tx Side In ADD State NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5790 |
gfarEndManualSwitchBackToWorkingSpanFar End Manual Switch Back to Working - Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5800 |
gfarEndForcedSwitchBackToWorkingSpanFar End Forced Switch Back to Working - Span NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5810 |
guniversalTransponderModuleHardwareFailureUniversal Transponder Module Hardware Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5820 |
guniversalTransponderModuleCommunicationFailureUniversal Transponder Module Communication Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5830 |
gpluginModuleRangeSettingsMismatchPlug-in Module Range Settings Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5840 |
glcasVcgMemberTxSideInDnuStateLCAS VCG Member Tx Side In DNU State NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5850 |
glcasControlWordCrcCheckFailureLCAS Control Word CRC Check Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5860 |
glcasVcgMemberRxSideInFailStateLCAS VCG Member Rx Side In FAIL State NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5870 |
gsignalLossOnDataInterfaceSignal Loss on Data Interface NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5880 |
gsynchronizationLossOnDataInterfaceSynchronization Loss on Data Interface NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5890 |
gportFAILPORT FAIL NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5900 |
gunreachablePortTargetPowerUnreachable port target power NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5910 |
gportAddPowerDegradeLowPort Add Power Degrade Low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5920 |
gportAddPowerDegradeHighPort Add Power Degrade High NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5930 |
gportAddPowerFailLowPort Add Power Fail Low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5940 |
gportAddPowerFailHighPort Add Power Fail High NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.5950 |
gautomaticPowerControlTerminatedOnManualRequestAutomatic Power Control Terminated on Manual request NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6000 |
goduk1AlarmIndicationSignalODUk-1: Alarm Indication Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6010 |
goduk2AlarmIndicationSignalODUk-2: Alarm Indication Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6020 |
goduk3AlarmIndicationSignalODUk-3: Alarm Indication Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6030 |
goduk4AlarmIndicationSignalODUk-4: Alarm Indication Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6040 |
gtemperatureReadingMismatchBetweenSCCardsTemperature Reading Mismatch Between SC Cards NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6050 |
gvoltageReadingMismatchBetweenSCCardsVoltage Reading Mismatch Between SC Cards NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6060 |
galarmsSuppressedonOutOfGroupVcatMemberAlarms Suppressed on Out-Of-Group VCAT Member NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6070 |
gblsrSoftwareVersionMismatchBLSR Software Version Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6080 |
goptimized1Plus1ApsPrimaryFacilityOptimized 1+1 APS Primary Facility NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6090 |
goptimized1Plus1ApsPrimarySectionMismatchOptimized 1+1 APS Primary Section Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6100 |
goptimized1Plus1ApsInvalidPrimarySectionOptimized 1+1 APS Invalid Primary Section NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6110 |
gcompositeClockHighLineVoltageComposite Clock High Line Voltage NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6120 |
gberThresholdExceededForSignalDegradeVtBER Threshold Exceeded For Signal Degrade - VT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6130 |
gberThresholdExceededForSignalFailureVtBER Threshold Exceeded For Signal Failure - VT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6140 |
gspanLengthOutOfRangeSpan Length Out of Range NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6150 |
gidleSignalConditionIdle Signal Condition NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6170 |
gidleSignalConditionInTxIdle Signal Condition in TX NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6180 |
gvtPathTraceIdentifierMismatchVT Path Trace Identifier Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6190 |
glossOfFrameInTXLoss of Frame in TX NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6200 |
gprovisioningMismatchProvisioning Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6210 |
gsectionTraceIdentifierMismatchSection Trace Identifier Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6220 |
gregeneratorSectionTraceIdentifierMismatchRegenerator Section Trace Identifier Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6230 |
gswitchingMatrixModuleFailureWorkingSwitching Matrix Module Failure - Working NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6240 |
gswitchingMatrixModuleFailureProtectSwitching Matrix Module Failure - Protect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6250 |
gslotCommunicationDisabledSlot Communication Disabled NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6260 |
gsessionTimeLimitExpiredSession Time Limit Expired NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6270 |
guserPasswordChangeRequiredUser Password Change Required NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6280 |
gisisAdjacencyFailureISIS Adjacency Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6290 |
gmsspSoftwareVersionMismatchMSSP Software Version Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6300 |
gremoteAuthenticationFailSeeAuditLogRemote Authentication Fail - See Audit Log NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6310 |
gillegalRouteAdditionToNetworkIllegal route addition to the Network NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6320 |
gringIsSquelchingStsTrafficRing Is Squelching STS Traffic NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6330 |
gringIsSquelchingVtTrafficRing Is Squelching VT Traffic NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6340 |
garchiveOfAuditLogFailedArchival of Audit Log Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6350 |
grprWrappedRPR Wrapped NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6360 |
gshelfCommunicationFailureShelf Communication Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6370 |
gduplicatedShelfIdentifierDuplicated Shelf Identifier NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6380 |
gsoftwareMismatchSoftware Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6390 |
glmpFailureLMP Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6400 |
gopticalTerminationIncompleteOptical Termination Incomplete NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6410 |
gforwardDefectIndicationForward Defect Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6420 |
gpayloadMissingIndicationPayload Missing Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6430 |
gspanMeasurementCannotBePerformedSpan loss not checked NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6440 |
gringIsSquelchingHighOrderTrafficRing Is Squelching Higher Order Traffic NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6450 |
gringIsSquelchingLowOrderTrafficRing Is Squelching Lower Order Traffic NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6460 |
gbadPacketCountExceedsThresholdBad Packet Count Exceeds Threshold NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6470 |
glinkLayerKeepAliveFailureLink Layer Keep-Alive Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6480 |
gautonegotiationRemoteFailureIndicationAuto-Negotiation Remote Failure Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6490 |
gtrailSignalFailTrail Signal Fail NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6500 |
gds1LoopbackCommandSentToFarEndDS1 Loopback Command Sent To Far End NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6510 |
gmultiplexSectionSignalDegradedMultiplex Section - Signal Degraded NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6520 |
gmultiplexSectionExcessiveErrorsMultiplex Section - Excessive Errors NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6530 |
ghighOrderPathSignalDegradedHigh Order Path - Signal Degraded NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6540 |
ghighOrderPathExcessiveErrorsHigh Order Path - Excessive Errors NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6550 |
glowOrderPathSignalDegradedLow Order Path - Signal Degraded NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6560 |
glowOrderPathExcessiveErrorsLow Order Path - Excessive Errors NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6570 |
gregeneratorSectionDccTerminationFailureRegenerator Section - DCC Termination Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6580 |
gnetworkMemoryPoolLowNetwork Memory Pool Low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6590 |
gospfRoutingTableOverflowOSPF Routing Table Overflow NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6600 |
gautoLaserShutdownDisabledAuto Laser Shutdown Disabled NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6610 |
gwavelengthOutOfLockWavelength Out of Lock NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6620 |
grprProtectionIsActiveRPR Protection Is Active NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6630 |
gmaxRPRStationNumberExceededMax RPR Station Number Exceeded NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6640 |
grprProtectionConfigurationMismatchedRPR Protection Configuration Mismatched NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6650 |
greservedBandwidthLinkRateExceededOnRinglet0Reserved Bandwidth Link Rate Exceeded On Ringlet0 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6660 |
greservedBandwidthLinkRateExceededOnRinglet1Reserved Bandwidth Link Rate Exceeded On Ringlet1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6670 |
grprInterfaceInPassThroughModeRPR Interface In Pass Through Mode NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6680 |
grprPeerNodeIsMissingRPR Peer Node is Missing NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6690 |
grprRiFailureRPR RI Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6700 |
grprSignalFailureRPR Signal Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6710 |
grprSignalDegradeRPR Signal Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6720 |
ginterlinkFailureADM Peer Cards Interlink Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6730 |
gapcWrongGainAPC Wrong Gain Set Point NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6740 |
grprSpanMismatchRPR Span Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6750 |
gefmRemoteFaultIndicationCriticalEventEFM Remote Fault Indication- Critical Event NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6760 |
gefmRemoteFaultIndicationDyingGaspEFM Remote Fault Indication- Dying Gasp NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6770 |
gefmRemoteFaultIndicationLinkFaultEFM Remote Fault Indication- Link Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6780 |
gefmLinkMonitoringErroredSymbolPeriodEventEFM Link Monitoring- Errored Symbol Period Event NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6790 |
gefmLinkMonitoringErroredFrameEventEFM Link Monitoring- Errored Frame Event NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6800 |
gefmLinkMonitoringErroredFramePeriodEventEFM Link Monitoring- Errored Frame Period Event NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6810 |
gefmLinkMonitoringErroredFrameSecondsSummaryEFM Link Monitoring- Errored Frame Seconds Summary NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6820 |
gefmRemoteLoopbackRequestFailedEFM Remote Loopback Request Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6830 |
gfastAutomaticProtectionSwitchingFast Automatic Protection Switching NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6840 |
gfastAutomaticProtectionSwitchingConfigMismatchFast Automatic Protection Switching Config Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6850 |
glcasSinkGroupErrorLCAS Sink Group Error NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6860 |
glcasVcgMemberRxSideInDnuStateLCAS VCG Member Rx Side In DNU State NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6870 |
gfcDistanceExtFuncNotEstablishedFibre Channel Distance Extension Function Not Established NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6880 |
gnonCiscoPPMInsertedNon Cisco PPM Inserted NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6890 |
gunqualifiedPPMInsertedUnqualified PPM Inserted NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6900 |
gftaMismatchFanTray Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6910 |
gcardPortsUnableToProvideProtectionCard/Ports Unable To Provide Protection NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6920 |
glmpSignalDegradeLMP Signal Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6930 |
glmpSignalFailureLMP Signal Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6940 |
glmpUnallocatedDataLinkLMP Unallocated Data Link NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6950 |
gfrontPortLinkLossTCC Front Port Link Loss NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6960 |
gbertEnblBERT Enabled NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6970 |
gbertSyncFailBERT Synchronization Status Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6975 |
gworkQueueFullWork Queue Full NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.6980 |
gequipmentPowerFailureAtConnectorAEquipment Power Failure At Connector A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7000 |
gequipmentPowerFailureAtConnectorBEquipment Power Failure At Connector B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7005 |
gequipmentPowerFailureAtReturnConnectorAEquipment Power Failure At Return Connector A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7010 |
gequipmentPowerFailureAtReturnConnectorBEquipment Power Failure At Return Connector B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7015 |
gloginFailThresholdExceededInvalid login attempt threshold exceeded NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7020 |
gconnectionIdMismatchOnMatrixAConnection ID mismatch on Matrix A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7025 |
gconnectionIdMismatchOnMatrixBConnection ID mismatch on Matrix B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7030 |
gmanufacturingEepromFailureManufacturing data memory (EEPROM) failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7035 |
gequipmentFailureHighTemperatureEquipment failure high temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7040 |
glaserBiasCurrentHighLaser bias current high NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7045 |
ghighLaserTemperatureHigh laser temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7050 |
gbridgeAndRollHasOccurredBridge and Roll Has Occurred NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7055 |
gbridgeAndRollIsPendingAValidSignalBridge and Roll is Pending a Valid Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7060 |
gairFlowAir Flow NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7065 |
gpartialFanFailurePartsFailurePartial Fan Failure - Parts Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7070 |
gunprotectedSyncronizationEquipmentUnprotected Synchronization Equipment NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7075 |
gunprotectedMatrixEquipmentUnprotected Matrix Equipment NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7080 |
gmatrixEquipmentUnavailableMatrix Equipment Unavailable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7085 |
gcontrolBusFailureTscAControl Bus Failure - TSC A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7090 |
gcontrolBusFailureTscBControl Bus Failure - TSC B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7095 |
gpayloadBusFailureMatrixAPayload Bus Failure - Matrix A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7100 |
gpayloadBusFailureMatrixBPayload Bus Failure - Matrix B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7105 |
gmatrixOperationSuspendedMatrix Operation Suspended NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7110 |
gclockFailureTscClock Module Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7115 |
gpayloadLoopbackLoopback - Payload NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7120 |
gdccChannelLossDCC Channel Loss NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7125 |
greptPmMsgInhibitedAutonomous PM Report Message Inhibited NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7130 |
gloopbackCrsLoopback - Cross Connect NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7135 |
gsyncRefFreqOutOfBoundSynchronization Reference Frequency Out Of Bounds NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7140 |
gsystemUpgradeInProgressSystem Upgrade In Progress NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7145 |
geqptFailToBootEquipment Fails To Boot NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7150 |
geqptPowerFailureEquipment Power Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7155 |
gclockBusFailureTscAClock Bus Failure - Shelf Controller A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7160 |
gclockBusFailureTscBClock Bus Failure - Shelf Controller B NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7165 |
gpowerFuseFailurePower Fuse Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7170 |
gcontrolCommunicationsEquipmentFailureControl Communication Equipment Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7175 |
gdifferentSoftwareVersionDifferent Software Version NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7180 |
gospfHelloFailOSPF Hello Fail NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7185 |
gclockModuleFrequencyMismatchClock Module Frequency Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7190 |
getherPortSwitchTSC switched to alternate ethernet port NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7195 |
gopenIOSlotsOpen IO Slot(s) NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7200 |
gequipmentBootInProgressEquipment boot in-progress. NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7205 |
glossOfClockFromMateShelfControllerLoss of Clock from mate Shelf Controller NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7210 |
gvirtualLanAlarmIndicationSignalVirtual Lan AIS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7225 |
gdcuLossFailureDCU Loss Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7230 |
gochncMaintenanceOCHNC Maintenance NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7235 |
gramanLaserShutdownRaman Laser Shutdown NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7240 |
glosOfRamanSignalLoss Of Raman Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7245 |
gmcastMacTableFullMulticast Mac Address Table Full NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7250 |
gmulticastMacAddressAliasingMulticast Mac Address Aliasing NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7255 |
gramanPwrProtOnRaman Power Protection On NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7260 |
gcppPeerNotRespondingCPP Peer Not Responding NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7265 |
gvoaControlLoopDisableDueToExcessiveCounterPropagationLightVOA Control Loop Disable Due To Excessive Counter-Propagation Light NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7275 |
gwizardIsRunningWizard Is Running NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7280 |
gramanGainNotReachedRaman Span Not Tuned NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7285 |
gpprForwardDefectIndicationpprForwardDefectIndication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7295 |
gpprBackwardDefectIndicationpprBackwardDefectIndication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7300 |
gpprCoordinatedMaintenancepprCoordinatedMaintenance NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7305 |
gpprTriggerThresholdBERExceededpprTriggerThresholdBERExceeded NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7310 |
glocalFaultLocal Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7315 |
gremoteFaultRemote Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7320 |
gefmRemoteLoopbackConfiguredEFM Port In Remote Loopback NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7325 |
gefmPeerMissingEFM Link To Peer Missing NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7330 |
geqptDegradeEquipment Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7335 |
gexcessiveBackPropagationExcessive Back Propagation NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7340 |
gremoteMaintenanceEndPointIsDownCFM Remote Maintenance End Point Is Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7345 |
gcrossConnectedCFMServiceCross Connected CFM Service NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7350 |
gcfmLoopCFM Loop NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7355 |
gcfmConfigurationErrorCFM Configuration Error NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7360 |
goutOfChannelGroupBundleOut Of Channel Group Bundle NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7365 |
grepNeighborAdjacencyFailureREP Neighbor Adjacency Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7370 |
grepLinkFlappingREP Link Flapping NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7375 |
gfaultInREPSegmentFault In REP Segment NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7380 |
gprimaryREPEdgePortElectedPrimary REP Edge Port Elected NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7385 |
gsecondaryREPEdgePortElectedSecondary REP Edge Port Elected NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7390 |
gstcnREPGeneratedSTCN REP Generated NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7395 |
gvlbREPActivatedVLB REP Activated NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7400 |
gvlbREPTriggerSoakingDelayActiveVLB REP Trigger Soaking Delay Active NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7405 |
gwanSynclossEthernet Syncloss On WAN Port NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7410 |
glaserShutdownDueToWavelengthDriftlaser Shutdown Due To Wavelength Drift NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7415 |
gmanualLaserRestartmanual Laser Restart NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7420 |
glaserShutdownDueToNonCiscoPPMInsertedlaserShutdownDueToNonCiscoPPMInserted NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7425 |
gethernetOSCTerminationFailureEthernet OSC Termination Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7430 |
gsoftwareSignatureVerificationFailedsoftware Signature Verification Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7445 |
gprotectVolumeSoftwareSignatureVerificationFailedProtect Volume Software Signature Verification NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7450 |
gactiveVolumeSoftwareSignatureVerificationFailedActive Software Signature Verification Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7455 |
gpeerPortClientSignalFailDetectedPeer Port Client Signal Fail Detected NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7460 |
gchannelShutdownDuetoWavelengthDriftChannel Shutdown Due to Wavelength Drift NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7465 |
gusbWriteFailureUSB Write Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7475 |
gusbSyncInProgressUSB Sync in Progress NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7480 |
gautoSensingUnableToDetectValidPayloadAuto-Sensing Unable To Detect Valid Payload NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7485 |
gpayloadAutoSensingInProgressPayload Auto-Sensing In Progress NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7490 |
ggfpClientSignalFailDetectedDueToSiglossGFP Client Signal Fail Detected Due To Sigloss NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7495 |
ggfpClientSignalFailDetectedDueToSynclossGFP Client Signal Fail Detected Due To Syncloss NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7500 |
gpmdDegradePMD Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7510 |
gstandbyTccNEClockIsInternalClockStandby Tcc NE Clock Is Internal Clock NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7515 |
gchromaticDispersionValuechromatic Dispersion Value NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7520 |
gpacketTransportServiceFailedpacketTransportServiceFailed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7525 |
gsatellitePanelDiscoveryFailureSatellite Panel Discovery Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7530 |
gsatellitePanelActiveLinkFailureSatellite Panel Active Link Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7535 |
gsatellitePanelCommunicationFailureSatellite Panel Communication Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7540 |
gsatellitePanelImproperConfigurationSatellite Panel Improper Configuration NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7545 |
gsatellitePanelFanMismatchOfEquipmentAndAttributesSatellite Panel Fan Mismatch Of Equipment And Attributes NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7550 |
gsatellitePanelFanFailureSatellite Panel Fan Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7555 |
gsatellitePanelPartialFanFailureSatellite Panel Partial Fan Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7560 |
gsatellitePanelFANManufacturingDataMemoryEEPROMFailureSatellite Panel FAN Manufacturing Data Memory (EEPROM) Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7565 |
gsatellitePanelFANUnitIsMissingSatellite Panel FAN Unit Is Missing NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7570 |
gsatellitePanelIndustrialHighTemperatureSatellite Panel Industrial High Temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7575 |
gsatellitePanelHighTemperatureSatellite Panel High Temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7580 |
gsatellitePanelBatteryFailureASatellite Panel Battery Failure A NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7585 |
gplannedSwitchOverPlanned Switch Over NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7590 |
gprotectionCardConfigurationMismatchprotection Card Configuration Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7595 |
grouterProcessorSwitchOverRouter Processor Switch Over NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7600 |
grunningLowOnResourcesRunning Low On Resources NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7605 |
gnoMoreResourcesAreAvailableNo More Resources Are Available NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7610 |
gesmcFailureESMC Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7615 |
glicenseWillExpireWithin24Hourslicense Will Expire Within 24 Hours NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7620 |
glicenseWillExpireAnytimeAfter1DayButBefore14Dayslicense Will Expire Anytime After 1Day But Before 14 Days NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7625 |
glicenseIsExpiredlicense Is Expired NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7630 |
glicenseCountViolationlicense Count Violation NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7635 |
gtemporaryLicenseIsInUseTemporary License Is In Use NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7640 |
gevaluationLicenseIsInUseEvaluation License Is In Use NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7645 |
glicenseIsMissingLicense Is Missing NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7650 |
gpseudowireDownPseudowire Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7655 |
gworkingPseudowireControlPlaneDownWorking Pseudowire Control Plane Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7660 |
gprotectPseudowireControlPlaneDownProtect Pseudowire Control Plane Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7665 |
gworkingPseudowireConnectivityCheckDownWorking Pseudowire Connectivity Check Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7670 |
gprotectPseudowireConnectivityCheckDownProtect Pseudowire Connectivity Check Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7675 |
gpseudowireTrafficSwitchedToPretectionPseudowire Traffic Switched To Pretection NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7680 |
gworkingPseudowireLocalAcTxPortFaultWorking Pseudowire Local AcTx Port Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7685 |
gprotectPseudowireLocalAcTxPortFaultProtect Pseudowire Local AcTx Port Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7690 |
gworkingPseudowireLocalAcRxPortFaultWorking Pseudowire Local AcRx Port Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7695 |
gprotectPseudowireLocalAcRxPortFaultProtect Pseudowire Local AcRx Port Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7700 |
gworkingPseudowireRemoteAcTxPortFaultWorking Pseudowire Remote AcTx Port Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7705 |
gprotectPseudowireRemoteAcTxPortFaultProtect Pseudowire Remote AcTx Port Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7710 |
gworkingPseudowireRemoteAcRxPortFaultworking Pseudowire Remote AcRx Port Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7715 |
gprotectPseudowireRemoteAcRxPortFaultProtect Pseudowire Remote AcRx Port Fault NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7720 |
gslaThresholdCrossAlertSLA Threshold Cross Alert NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7725 |
gprotectLocalPseudowireNotForwardingProtect Local Pseudowire Not Forwarding NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7730 |
gworkingRemotePseudowireNotForwardingWorking Remote Pseudowire Not Forwarding NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7735 |
gprotectRemotePseudowireNotForwardingProtect Remote Pseudowire Not Forwarding NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7740 |
gtpTunnelDownTp Tunnel Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7745 |
gworkingLabelSwitchedPathDownWorking Label Switched Path Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7750 |
gprotectLabelSwitchedPathDownProtect Label Switched Path Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7755 |
gworkingLabelSwitchedPathAlarmIndicationSignalWorking Label Switched Path Alarm Indication Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7760 |
gprotectLabelSwitchedPathAlarmIndicationSignalProtect Label Switched Path Alarm Indication Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7765 |
gworkingLabelSwitchedPathRemoteDefectIndicationWorking Label Switched Path Remote Defect Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7770 |
gprotectLabelSwitchedPathRemoteDefectIndicationProtect Label Switched Path Remote Defect Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7775 |
gbidirectionalForwardDetectionDownBidirectional Forward Detection Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7780 |
gtpTrafficSwitchedFromWorkingToProtectionTp Traffic Switched From Working To Protection NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7785 |
gworkingTpLockoutworking Tp Lockout NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7790 |
gprotectTpLockoutprotect Tp Lockout NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7795 |
gethernetFlowPointFailedEthernet Flow Point Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7800 |
gteTunnelDownTE Tunnel Down NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7805 |
gmacSystemLimitReachedMAC System Limit Reached NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7810 |
gmacBridgeDomainLimitReachedMAC Bridge Domain Limit Reached NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7815 |
gautoSensingDisabledAuto Sense Disabled NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7820 |
gsmBackwardIncomingAlignmentErrorSM Backward Incoming Alignment Error NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7825 |
gresourceAllocationFailedResource Allocation Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7830 |
glossOfDFBSignalloss Of DFB Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7835 |
gworkingLabelSwitchedPathLinkDownIndicationWorking Label Switched Path Link Down Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7840 |
gprotectLabelSwitchedPathLinkDownIndicationProtect Label Switched Path Link Down Indication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7845 |
gworkingLabelSwitchedPathLockReportWorking Label Switched Path Lock Report NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7850 |
gprotectLabelSwitchedPathLockReportProtect Label Switched Path Lock Report NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7855 |
gsatellitePanelBatteryFailureBsatellite Panel Battery FailureB NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7860 |
ghighBitErrorRateHigh Bit Error Rate NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7865 |
gbackPanelFacilityLoopbackBack Panel Facility Loopback NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7870 |
gbackPanelTerminalLoopbackBack Panel Terminal Loopback NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7875 |
gtrunkPayloadTypeMismatchPayload Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7880 |
ginvalidMuxponderConfigurationInvalid Muxponder Configuration NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7885 |
gcoolingProfileMismatchCooling Profile Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7890 |
gtrunkOduAlarmIndicationSignalTrunk ODU: Alarm Indication Signal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7895 |
gcompanionCardMissingCompanion Card Missing NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7900 |
gcontrolPlaneUnverifiedClearedAlarmsPresentControl Plane Unverified Cleared Alarms Present NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7905 |
gpowerConsumptionLimitHasCrossedPower Consumption Limit Has Crossed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7910 |
gmasterKeyExchangeFailedMaster Key Exchange Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7915 |
gunitHighTemperatureUnit High Temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7930 |
goverTemperatureUnitProtectedOver Temperature Unit Protected NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7935 |
gseqMismatchCountSequence Mismatch Count NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7945 |
gkeyProgramOnAlteraFpgaFailedKey Program On Altera FPGA Failed NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7960 |
gduplicateNodeControllerDetectedDuplicate Node Controller Detected NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7970 |
grestorationInProgRestoration in Progress NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7975 |
gramanPumpsCalibrationProcedureIsRunningRaman Calibration Running NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7980 |
gramanPumpsCalibrationIsScheduledToRunInTheNextMinutesRaman Calibration Pending NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.7985 |
godukTCM1AlarmIndicationSignalODUk Alarm Indication Signal TCM1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13100 |
godukTCM2AlarmIndicationSignalODUk Alarm Indication Signal TCM2 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13105 |
godukLockedDefectTCM1ODUk Locked Defect - TCM1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13110 |
godukLockedDefectTCM2ODUk Locked Defect - TCM2 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13115 |
gotukLossOfFrameOTUk: Loss Of Frame NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13120 |
godukOpenConnectionIndicationTCM1ODUk Open Connection Indication TCM1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13125 |
godukOpenConnectionIndicationTCM2ODUk Open Connection Indication TCM2 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13130 |
godukTrailTraceIdentifierMismatchTCM1ODUk Trail Trace Identifier Mismatch TCM1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13135 |
godukTrailTraceIdentifierMismatchTCM2ODUk Trail Trace Identifier Mismatch TCM2 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13140 |
godukSignalFailureTCM1ODUk Signal Failure - TCM1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13145 |
godukSignalFailureTCM2ODUk Signal Failure - TCM2 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13150 |
godukSignalDegradeTCM1ODUk Signal Degrade - TCM1 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13155 |
godukSignalDegradeTCM2ODUk Signal Degrade - TCM2 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13160 |
glossOfChannelLoss of Channel NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13165 |
gfecMismatchFEC Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13170 |
gtimSectionMonitorTraceIdentifierMismatchFailureTIM Section Monitor - Trace Identifier Mismatch Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13175 |
gautomaticLaserShutdownAutomatic Laser Shutdown NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13180 |
gshutterInsertionLossVariationDegradeLowShutter Insertion Loss Variation Degrade Low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13200 |
gopticalChannelDeactivationFailureOptical Channel de-activation failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13205 |
gshutterInsertionLossVariationDegradeHighShutter Insertion Loss Variation Degrade High NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13210 |
gnetworkTopologyIncompleteNetwork Topology Incomplete NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13215 |
gpluginModuleCommunicationFailurePlug-in Module Communication Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13220 |
gopticalNetworkTypeMismatchOptical Network Type Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13225 |
gopticalPowerDegradeLowLaser Power Degrade Low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13230 |
gautomaticPowerControlFailureAutomatic Power Control Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13235 |
gopticalPowerDegradeHighOptical Power Degrade High NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13240 |
gautomaticPowerControlDisabledAutomatic Power Control Disabled NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13245 |
gopticalPowerFailureLowOptical Power Failure Low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13250 |
gringIdMismatchRing Id Mismatch NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13255 |
gopticalPowerFailureHighOptical Power Failure High NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13260 |
glossOfContinuityLoss Of Continuity NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13270 |
gvariableOpticalAttenuatorDegradeLowVariable Optical Attenuator Degrade Low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13280 |
gvariableOpticalAttenuatorDegradeHighVariable Optical Attenuator Degrade High NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13290 |
gvariableOpticalAttenuatorFailureLowVariable Optical Attenuator Failure Low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13300 |
gvariableOpticalAttenuatorFailureHighVariable Optical Attenuator Failure High NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13310 |
glaserBiasDegradeLaser Bias Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13320 |
glaserBiasFailureaser Bias Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13330 |
glaserTemperatureDegradeLaser Temperature Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13340 |
gopticalAmplifierGainDegradeLowOptical Amplifier Gain Degrade Low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13350 |
gopticalAmplifierGainDegradeHighOptical Amplifier Gain Degrade High NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13360 |
gopticalAmplifierGainFailureLowOptical Amplifier Gain Failure Low NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13370 |
gopticalAmplifierGainFailureHighOptical Amplifier Gain Failure High NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13380 |
gopticalChannelConnectionFailureOptical Channel connection failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13390 |
gopticalChannelIncompleteOptical Channel Incomplete NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13395 |
gopticalChannelActivationFailureOptical Channel activation failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13400 |
glaserAutoPowerReductionLaser Auto Power Reduction NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13410 |
gcaseTemperatureDegradeCase Temperature Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13420 |
gfiberTemperatureDegradeFiber Temperature Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13430 |
gshutterOpenShutter Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13440 |
gawgTemperatureDegradeAWG Temperature Degrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13450 |
gawgTemperatureFailureAWG Temperature Failure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13460 |
gawgOverTemperatureAWG Over-Temperature NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13470 |
gopticalAmplifierInitializationOptical Amplifier Initialization NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13480 |
gawgWarmUpAWG Warm Up NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13490 |
gincSiglossIncoming Signal Loss on Fibre Channel Interface NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13510 |
gincSynclossIncoming Synchronization Loss on Fibre Channel Interface NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13515 |
gincGfpOutOfFrameOut Of Frame Detected by GFP Receiver NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13520 |
gincGfpSigLossClient Signal Loss Frames Detected by GFP Receiver NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13525 |
gincGfpSyncLossClient Sychronization Loss Frames Detected by GFP Receiver NOTIFICATION-TYPE .1.3.6.1.4.1.3607.2.20.0.13530 |
cerentConformanceThis node is created for compliance. Has
objects as required by the RFCs OBJECT IDENTIFIER .1.3.6.1.4.1.3607.5.10 |
cerentGenericGroupsAll the objects and events are
grouped under this for conformance OBJECT IDENTIFIER .1.3.6.1.4.1.3607.5.10.10 |
cerentComplianceThe compliance statements
for Cisco ONS 15327, 15310. OBJECT IDENTIFIER .1.3.6.1.4.1.3607.5.10.20 |