CERENT-GENERIC-MIB

This module provides the definitions for generic objects and notifications of Cisco ONS network device, ONS 15327, 15310.
Main OID:
cerentGenericMibModule.1.3.6.1.4.1.3607.1.10.40
982
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

982 total
Object Name
cerentGenericMibModuleThis module provides the definitions for generic objects and notifications of Cisco ONS network device, ONS 15327, 15310.
MODULE-IDENTITY
.1.3.6.1.4.1.3607.1.10.40
cerentGenericObjectsAll the generic objects definitions are grouped under this
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.2.10
cerentGenericCommonObjectsGroupThe group to combine all the Cisco OTBU common objects
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.2.10.10
cerentGenericEnableNotificationThis variable indicates whether the system produces notifications. A value=FALSE will prevent notifications from being sent by this system.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.10.10
cerentGenericNodeTimeIndicates current local time as reflected by the Cisco OTBU equipment. The format this scalar is YYYYMMDDhhmmss{S/D}. E.g., 20011103133453D means 1:34:53 PM PDT on 03/Nov/2001 19990614095436S means 9:54:36 AM PST on 14/Jun/1999. If the last octet is S then the time is standard time. Otherwise it is D to indicate it is daylight saving time, if applicablero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.10.20
cerentGenericSentNotificationsA count of v1+v2 notifications sent out by the agent. Resets to zero after cold/warm start.ro
Counter32
.1.3.6.1.4.1.3607.2.10.10.30
cerentGenericLastChangeTimeThe value of sysUpTime at the time a conceptual row is created or deleted in cerentGenericAlarmTablero
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.10.40
cerentGenericMultishelfEnabledThis variable indicates whether the system is configured in multi-shelf mode or single-shelf mode.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.10.50
cerentGenericGeneralGroupAnother class of objects found in Cisco ONS 15327, 15310
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.2.10.20
cerentGenericSoftwareVersionIndicates the version of software that is used in Cisco ONS Network element, ONS 15327, 15310. E.g., 2.2.03ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.20.10
cerentGenericAlarmGroupThe group that will represent all the alarm info in the Cisco ONS network element, ONS 15327, 15310
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.2.10.30
cerentGenericAlarmCountTotal number of active alarms in the Cisco ONS network element, ONS 15327, 15310. This equals the total number of rows in cerentGenericAlarmTable at any time.ro
Unsigned32
.1.3.6.1.4.1.3607.2.10.30.10
cerentGenericAlarmTableThis table has all currently raised conditions for the network node. A Condition is a fault or status detected by hardware or software.
SEQUENCE OF CerentGenericAlarmEntry
.1.3.6.1.4.1.3607.2.10.30.20
cerentGenericAlarmEntryRow definition for cerentGenericAlarmTable
CerentGenericAlarmEntry
.1.3.6.1.4.1.3607.2.10.30.20.1
cerentGenericAlarmIndexUniquely identifies each entry in alarm table. May not start with one and there may be some missing numbers.
Integer32 ( 1..2147483647 ) -- all +ve values
.1.3.6.1.4.1.3607.2.10.30.20.1.10
cerentGenericAlarmObjectTypeThis will indicate what is the type of the entity which raised this alarm. ( E.g., DS3, etherBridge, VT-TERM, etc ) The NMS is expected to use this value to decide which table to poll for further info about the alarmro
CerentGenericEntityClass
.1.3.6.1.4.1.3607.2.10.30.20.1.20
cerentGenericAlarmSlotNumberThis will indicate what is the slot of the object which raised this alarm. If not relevant to the alarm, will be zero.ro
Integer32
.1.3.6.1.4.1.3607.2.10.30.20.1.30
cerentGenericAlarmPortNumberThis will indicate what is the port of the object which raised this alarm.ro
CerentPortNumber (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.30.20.1.40
cerentGenericAlarmLineNumberThis will indicate what is the port of the object which raised this alarm. If not relevant to the alarm, will be zero.ro
Integer32
.1.3.6.1.4.1.3607.2.10.30.20.1.50
cerentGenericAlarmObjectIndexEvery alarm is raised by an object and this object is an entry in a specific table. This is the index of the object in that table E.g., if the alarm is interface related, this index is the index of the interface in the interface table.ro
Integer32
.1.3.6.1.4.1.3607.2.10.30.20.1.60
cerentGenericAlarmTypeIndicates what the exact nature of the alarm. See the CerentGenericAlarmType TC for mapping detailsro
CerentGenericAlarmType
.1.3.6.1.4.1.3607.2.10.30.20.1.70
cerentGenericAlarmStateSpecifies alarm severity and service affecting status ( SA/NSA ). Only {minor|major|critical}+{NA|NSA} alarms and standing conditions will be represented here. However, this mib object is included in each trap dispatched and in the trap this object can contain all the possible values of CerentNotificationClass type.ro
CerentNotificationClass (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.30.20.1.80
cerentGenericAlarmTimeStampThe value of sysUpTime when this entry was created. This is accurate only upto a second.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.30.20.1.90
cerentGenericAlarmObjectNameTL1-style user-visible name which uniquely identifies an object in the systemro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.30.20.1.100
cerentGenericAlarmAdditionalInfoAdditional information for the alarm object. In the current version of the MIB, this object contains the following information :- a) Provisioned description for alarms of type 'failureDetectedExternalToTheNE'. This object would be a null string if no additional information is specified.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.30.20.1.110
cerentGenericAlarmSeveritySpecifies severity of the alarm being sent out.ro
CerentAlarmSeverity (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.30.20.1.120
cerentGenericAlarmStatusRepresents if an alarm is currently raised or cleared.ro
CerentAlarmStatus (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.30.20.1.130
cerentGenericAlarmServiceAffectingSpecifies whether the alarm that is being sent out is Service Affecting (SA) or Non- Service Affecting (NSA).ro
CerentAlarmServiceAffecting (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.30.20.1.140
cerentGenericReportedAlarmCountNumber of alarms currently reported against Cisco ONS platform. This equals the number of rows in cerentGenericReportedAlarmTable.ro
Unsigned32
.1.3.6.1.4.1.3607.2.10.30.30
cerentGenericReportedAlarmTableThis table has the list of alarms currently reported for the Cisco ONS node. It does not include any cleared alarms. The alarms in this table are in compliance with Telcordia GR-253. This means that if a network problem causes two alarms, such a as loss of frame(LOF) and loss of signal(LOS), only LOS alarm will be in this table because it supersedes and replaces the LOF.
SEQUENCE OF CerentGenericReportedAlarmEntry
.1.3.6.1.4.1.3607.2.10.30.40
cerentGenericReportedAlarmEntryRow definition for cerentGenericReportedAlarmTable
CerentGenericReportedAlarmEntry
.1.3.6.1.4.1.3607.2.10.30.40.1
cerentGenericReportedAlarmIndexIdentifies each entry in ReportedAlarm table. May not start with one and there may be some missing numbers.
Integer32 ( 1..2147483647 ) -- all +ve values
.1.3.6.1.4.1.3607.2.10.30.40.1.10
cerentGenericReportedAlarmObjectTypeThis will indicate the type of the entity which raised this alarm. ( E.g., DS3, etherBridge, VT-TERM, etc ) The NMS is expected to use this value to decide which table to poll for further info about the alarmro
CerentGenericEntityClass
.1.3.6.1.4.1.3607.2.10.30.40.1.20
cerentGenericReportedAlarmSlotNumberThis will indicate what is the slot of the object which raised this alarm. If not relevant to the alarm, will be zero.ro
Integer32
.1.3.6.1.4.1.3607.2.10.30.40.1.30
cerentGenericReportedAlarmPortNumberThis will indicate what is the port of the object which raised this alarm.ro
CerentPortNumber (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.30.40.1.40
cerentGenericReportedAlarmObjectIndexEvery alarm is raised by an object and this object is an entry in a specific table. This is the index of the object in that table E.g., if the alarm is interface related, this is the index of the interface in the interface table.ro
Integer32
.1.3.6.1.4.1.3607.2.10.30.40.1.50
cerentGenericReportedAlarmTypeIndicates the exact nature of the alarm.ro
CerentGenericAlarmType
.1.3.6.1.4.1.3607.2.10.30.40.1.60
cerentGenericReportedAlarmTimeStampThe value of sysUpTime when this entry was created. This is accurate only upto a second.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.30.40.1.70
cerentGenericReportedAlarmObjectNameTL1-style user-visible name which uniquely identifies an object in the systemro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.30.40.1.80
cerentGenericReportedAlarmAdditionalInfoAdditional information for the alarm object. In the current version of the MIB, this object contains the following information :- a) Provisioned description for alarms of type 'failureDetectedExternalToTheNE'. This object would be a null string if no additional information is specified.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.10.30.40.1.90
cerentGenericReportedAlarmSeveritySpecifies severity of the alarm.ro
CerentAlarmSeverity (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.30.40.1.100
cerentGenericReportedAlarmStatusRepresents if the alarm is currently raised or cleared.ro
CerentAlarmStatus (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.30.40.1.110
cerentGenericReportedAlarmServiceAffectingSpecifies whether the alarm that is being sent out is Service Affecting (SA) or Non- Service Affecting (NSA).ro
CerentAlarmServiceAffecting (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.30.40.1.120
cerentGenericThresholdGroupThe group that will represent all the threshold info in the Cisco ONS network element, ONS 15327, 15310
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.2.10.40
cerentGenericThresholdTableThis table holds all the provisioned Thresholds. This table is currently unimplemented.
SEQUENCE OF CerentGenericThresholdEntry
.1.3.6.1.4.1.3607.2.10.40.10
cerentGenericThresholdEntryRow definition for cerentGenericThresholdTable
CerentGenericThresholdEntry
.1.3.6.1.4.1.3607.2.10.40.10.1
cerentGenericThresholdIndexUniquely identifies each entry in Threshold table. May not start with one and there will be some missing numbers.
Integer32
.1.3.6.1.4.1.3607.2.10.40.10.1.10
cerentGenericThresholdMonitorTypeThis object indicates the type of metric monitored.ro
CerentMonitorType (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.40.10.1.20
cerentGenericThresholdLocationThis indicates if it near or far endro
CerentLocation (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.40.10.1.30
cerentGenericThresholdPeriodThe sampling interval period is indicated herero
CerentPeriod (CERENT-TC)
.1.3.6.1.4.1.3607.2.10.40.10.1.40
cerentGenericThresholdSetValueThe value of this object will be threshold that was provisioned by the NMSro
Integer32
.1.3.6.1.4.1.3607.2.10.40.10.1.50
cerentGenericThresholdCurrentValueThe current value of the counter which measures the metric. This column will never be implemented as these values are already accessible through IETF MIB objects.ro
Integer32
.1.3.6.1.4.1.3607.2.10.40.10.1.60
cerentGenericThresholdDetectTypeThe value of this object will be the detect type for the threshold.ro
Enumeration
.1.3.6.1.4.1.3607.2.10.40.10.1.70
cerentGenericEventsPlace holder for all notifications of Cisco ONS network device, ONS 15327, 15310
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.2.20
cerentGenericV2EventsThe sub-identifier has to be zero, as part of the interoperability agreement between SNMPv1 and SNMPv2 worlds.
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.2.20.0
galarmUnknownalarm unknown
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1
galarmCutoffIsInManualModealarm cutoff is in manual mode
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.10
gfailureDetectedExternalToTheNEfailure detected External to the NE
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.20
gexternalErrorexternal error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.30
gexcessiveSwitchingexcessive switching
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.40
gsdccTerminationFailureSDCC Termination failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.50
gincomingFailureConditionincoming failure condition
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.60
galarmIndicationSignalalarm indication signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.70
galarmIndicationSignalLinealarm indication signal LINE
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.80
galarmIndicationSignalPathalarm indication signal Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.90
galarmIndicationSignalVTalarm indication signal VT
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.100
gapsChannelFailurechannel failure APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.110
gchannelByteFailureAPSchannel Byte failure APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.120
gchannelProtectionSwitchingChannelMatchFailureAPSchannel Protection Switching Channel Match failure APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.130
gchannelAutomaticProtectionSwitchModeMismatchAPSchannel Automatic Protection Switch Mode Mismatch APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.140
gfarEndProtectionLineFailurechannel far end protection line failure APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.150
ginconsistentAPSCodeInconsistent APS code
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.160
gimproperAPSCodeImproper APS code APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.170
gnodeIdMismatchNode Id Mismatch APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.180
gchannelDefaultKAPSDefault K APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.190
gconnectionLossConnection loss APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.200
gbipolarViolationbipolar Violation
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.210
gcarrierLossOnTheLANcarrier Loss on the LAN
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.220
gconcatenationErrorSTSconcatenation error STS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.230
gexcessCollisionsOnTheLANexcess collisions on the LAN
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.240
gfacilityFailurefacility critical alarm caused by DS3 facility failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.250
gfarEndAISfar end AIS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.260
gfarEndMultipleDS1LOSDetectedOnDS3far end Multiple DS1 LOS detected on DS3
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.270
gfarEndDS1EqptFailNonServiceAffectingfar end DS1 eqpt fail non service affecting
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.280
gfarEndDS1EqptFailServiceAffectingfar end DS1 Eqpt fail service affecting
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.290
gfarEndSingleDS1LOSfar end Single DS1 LOS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.300
gfarEndDS3EqptFailNonServiceAffectingfar end DS3 Eqpt failure non service affecting
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.310
gfarEndDS3EqptFailServiceAffectingfar end DS3 Eqpt failure service affecting
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.320
gfarEndCommonEquipmentFailureNonServiceAffectingfar end common Eqpt failure non service affecting
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.330
gfarEndIDLEfar end IDLE
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.340
gfarEndLOSfar end LOS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.350
gfarEndLOFfar end LOF
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.360
gfarEndBlockErrorfar End Block Error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.370
gds3IdleConditionidle Condition DS3
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.380
glossOfFrameloss of Frame
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.390
glossOfPointerloss of Pointer
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.400
glossOfPointerPathloss of Pointer Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.410
glossOfPointerVTloss of Pointer VT
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.420
glossOfSignalloss of Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.430
goutOfFrameout of Frame
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.440
gpathSelectorFailurepath Selector inability to swtich to a valid signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.450
gremoteAlarmIndicationremote Alarm Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.460
gremoteFailureIndicationremote Failure Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.470
gremoteFailureIndicationLineremote Failure Indication LINE
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.480
gremoteFailureIndicationPathremote Failure Indication Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.490
gremoteFailureIndicationVTremote Failure Indication VT
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.500
gsignalDegradeSignal Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.510
gseverelyErroredFrameseverely Errored Frame
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.520
gsignalFailureSignal Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.530
gsignalLabelMismatchFailuresignal Label Mismatch Failures
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.540
gpayloadDefectIndicationPayload Defect Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.550
gpayloadDefectIndicationPathPayload Defect Indication - Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.560
gpayloadLabelMismatchPathPayload Label Mismatch - Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.570
gsignalLabelMismatchFailurePayloadLabelMismatchVTsignal Label Mismatch Failure Payload Label Mismatch VT
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.580
gunequippedPathUnequipped - Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.590
gsignalLabelMismatchFailureUnequippedVTsignal Label Mismatch Failure Unequipped VT
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.600
glossOfSynchronizationLoss of Synchronization
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.610
goutOfSynchronizationOut of Synchronization
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.620
gprimarySynchronizationReferenceFailurePrimary Synchronization Reference Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.630
gsecondarySynchronizationReferenceFailureSecondary Synchronization Reference Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.640
gthirdSynchronizationReferenceFailureThird Synchronization Reference Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.650
gfourthSynchronizationReferenceFailureFourth Synchronization Reference Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.660
gfifthSynchronizationReferenceFailureFifth Synchronization Reference Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.670
gsixthSynchronizationReferenceFailureSixth Synchronization Reference Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.680
gfailedToReceiveSynchronizationStatusMessagefailed to receive Synchronization Status Message
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.690
gsynchronizationStatusMessagesAreDisabledOnThisInterfacesynchronization Status Messages are disabled on this interface
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.700
gstratum1PrimaryReferenceSourceTraceableStratum1 Primary Reference Source Traceable
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.710
gsynchronizedTraceabilityUnknownsynchronized Traceability Unknown
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.720
gstratum2Traceablestratum 2 Traceable
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.730
gtransitNodeClockTraceabletransit Node clock Traceable
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.740
gstratum3ETraceablestratum 3E Traceable
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.750
gstratum3Traceablestratum 3 Traceable
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.760
gsonetMinimumClockTraceableMinimum clock Traceable - SONET
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.770
gstratum4Traceablestratum 4 Traceable
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.780
gdoNotUseForSynchronizationdo not Use for Synchronization
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.790
greservedForNetworkSynchronizationUsereserved for Network Synchronization Use
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.800
goutgoingFailureConditionoutgoing failure condition
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.810
gremoteDefectIndicationLineremote Defect Indication LINE
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.820
gremoteDefectIndicationPathremote Defect Indication Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.830
gfreeRunningSynchronizationModefree Running Synchronization mode
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.840
gholdoverSynchronizationModeholdover synchronization mode
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.850
gfastStartSynchronizationModefast Start synchronization mode
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.860
ginternalFaultinternal hardware fault or failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.870
ginternalErrorerror Internal to the NE Detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.880
ginternalMessageErrorinternal Message Error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.890
gmismatchOfEquipmentAndAttributesmismatch of Equipment and Attributes
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.900
gwatchdogTimerTimeoutwatchdog Timer Timeout
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.910
gsoftwareFaultOrFailuresoftware Fault or failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.920
gsoftwareFaultDataIntegrityFaultsoftware Fault - Data integrity fault : The newly added provisioning or hardware has caused the database to grow beyond its limit. That is, the newly added object(s) in the system has(have) enough memory to exist onboard but too large to be saved in the database.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.930
gprogramFailureprogram failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.940
gcontrolEquipmentFailurecontrol Equipment failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.950
gprimaryNonVolatileBackupMemoryFailurecontrol Equipment Primary non volatile Backup Memory failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.960
gsecondaryNonVolatileBackupMemoryFailurecontrol Equipment Secondary non volatile Backup Memory failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.970
gcontrolBusFailurecontrol Equipment Control Bus failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.980
gcontrolBus1Failurecontrol Equipment Control Bus 1 failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.990
gcontrolBus2Failurecontrol Equipment Control Bus 2 failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1000
gtccAToShelfSlot1DROP1CommunicationFailurecommunication failure Controller A to Shelf SLOT 1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1010
gtccAToShelfSlot2DROP2CommunicationFailurecommunication failure Controller A to Shelf SLOT 2
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1020
gtccAToShelfSlot3DROP3CommunicationFailurecommunication failure Controller A to Shelf SLOT 3
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1030
gtccAToShelfSlot4DROP4CommunicationFailurecommunication failure Controller A to Shelf SLOT 4
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1040
gtccAToShelfSlot5TRUNK1CommunicationFailurecommunication failure Controller A to Shelf SLOT 5
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1050
gtccAToShelfSlot6TRUNK2CommunicationFailurecommunication failure Controller A to Shelf SLOT 6
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1060
gtccAToShelfSlot7TCCACommunicationFailurecommunication failure Controller A to Shelf SLOT 7
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1070
gtccAToShelfSlot8XCONACommunicationFailurecommunication failure Controller A to Shelf SLOT 8
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1080
gtccAToShelfSlot9AICCommunicationFailurecommunication failure Controller A to Shelf SLOT 9
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1090
gtccAToShelfSlot10XCONBCommunicationFailurecommunication failure Controller A to Shelf SLOT 10
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1100
gtccAToShelfSlot11TCCBCommunicationFailurecommunication failure Controller A to Shelf SLOT 11
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1110
gtccAToShelfSlot12TRUNK3CommunicationFailurecommunication failure Controller A to Shelf SLOT 12
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1120
gtccAToShelfSlot13TRUNK4CommunicationFailurecommunication failure Controller A to Shelf SLOT 13
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1130
gtccAToShelfSlot14DROP5CommunicationFailurecommunication failure Controller A to Shelf SLOT 14
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1140
gtccAToShelfSlot15DROP6CommunicationFailurecommunication failure Controller A to Shelf SLOT 15
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1150
gtccAToShelfSlot16DROP7CommunicationFailurecommunication failure Controller A to Shelf SLOT 16
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1160
gtccAToShelfSlot17DROP8CommunicationFailurecommunication failure Controller A to Shelf SLOT 17
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1170
gtccAToDCCAProcessorCommunicationFailurecommunication failure ControllerP A to ControllerJ A processor
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1180
gtccBToShelfSlot1DROP1CommunicationFailurecommunication failure Controller B to Shelf SLOT 1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1190
gtccBToShelfSlot2DROP2CommunicationFailurecommunication failure Controller B to Shelf SLOT 2
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1200
gtccBToShelfSlot3DROP3CommunicationFailurecommunication failure Controller B to Shelf SLOT 3
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1210
gtccBToShelfSlot4DROP4CommunicationFailurecommunication failure Controller B to Shelf SLOT 4
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1220
gtccBToShelfSlot5TRUNK1CommunicationFailurecommunication failure Controller B to Shelf SLOT 5
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1230
gtccBToShelfSlot6TRUNK2CommunicationFailurecommunication failure Controller B to Shelf SLOT 6
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1240
gtccBToShelfSlot7TCCACommunicationFailurecommunication failure Controller B to Shelf SLOT 7
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1250
gtccBToShelfSlot8XCONACommunicationFailurecommunication failure Controller B to Shelf SLOT 8
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1260
gtccBToShelfSlot9AICCommunicationFailurecommunication failure Controller B to Shelf SLOT 9
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1270
gtccBToShelfSlot10XCONBCommunicationFailurecommunication failure Controller B to Shelf SLOT 10
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1280
gtccBToShelfSlot11TCCBCommunicationFailurecommunication failure Controller B to Shelf SLOT 11
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1290
gtccBToShelfSlot12TRUNK3CommunicationFailurecommunication failure Controller B to Shelf SLOT 12
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1300
gtccBToShelfSlot13TRUNK4CommunicationFailurecommunication failure Controller B to Shelf SLOT 13
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1310
gtccBToShelfSlot14DROP5CommunicationFailurecommunication failure Controller B to Shelf SLOT 14
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1320
gtccBToShelfSlot15DROP6CommunicationFailurecommunication failure Controller B to Shelf SLOT 15
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1330
gtccBToShelfSlot16DROP7CommunicationFailurecommunication failure Controller B to Shelf SLOT 16
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1340
gtccBToShelfSlot17DROP8CommunicationFailurecommunication failure Controller B to Shelf SLOT 17
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1350
gtccBToDCCBProcessorCommunicationFailurecommunication failure ControllerP B to ControllerJ A processor
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1360
gcontrolEquipmentControlCommunicationsEquipmentFailurecontrol Equipment Control Communications equipment failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1370
gcontrolProcessorFailurecontrol Equipment Control processor failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1380
gworkingMemoryFailurecontrol Equipment Working memory failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1390
ginterconnectionEquipmentFailureinterconnection Equipment failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1400
gpayloadBusFailureToIOSlot1XCONSlot8interconnection Equipment failure Payload Bus 1 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1410
gpayloadBusFailureToIOSlot2XCONSlot8interconnection Equipment failure Payload Bus 2 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1420
gpayloadBusFailureToIOSlot3XCONSlot8interconnection Equipment failure Payload Bus 3 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1430
gpayloadBusFailureToIOSlot4XCONSlot8interconnection Equipment failure Payload Bus 4 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1440
gpayloadBusFailureToIOSlot5XCONSlot8interconnection Equipment failure Payload Bus 5 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1450
gpayloadBusFailureToIOSlot6XCONSlot8interconnection Equipment failure Payload Bus 6 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1460
gpayloadBusFailureToIOSlot12XCONSlot8interconnection Equipment failure Payload Bus 7 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1470
gpayloadBusFailureToIOSlot13XCONSlot8interconnection Equipment failure Payload Bus 8 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1480
gpayloadBusFailureToIOSlot14XCONSlot8interconnection Equipment failure Payload Bus 9 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1490
gpayloadBusFailureToIOSlot15XCONSlot8interconnection Equipment failure Payload Bus 10 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1500
gpayloadBusFailureToIOSlot16XCONSlot8interconnection Equipment failure Payload Bus 11 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1510
gpayloadBusFailureToIOSlot17XCONSlot8interconnection Equipment failure Payload Bus 12 Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1520
gpayloadBusFailureToIOSlot1XCONSlot10interconnection Equipment failure Payload Bus 1 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1530
gpayloadBusFailureToIOSlot2XCONSlot10interconnection Equipment failure Payload Bus 2 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1540
gpayloadBusFailureToIOSlot3XCONSlot10interconnection Equipment failure Payload Bus 3 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1550
gpayloadBusFailureToIOSlot4XCONSlot10interconnection Equipment failure Payload Bus 4 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1560
gpayloadBusFailureToIOSlot5XCONSlot10interconnection Equipment failure Payload Bus 5 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1570
gpayloadBusFailureToIOSlot6XCONSlot10interconnection Equipment failure Payload Bus 6 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1580
gpayloadBusFailureToIOSlot12XCONSlot10interconnection Equipment failure Payload Bus 7 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1590
gpayloadBusFailureToIOSlot13XCONSlot10interconnection Equipment failure Payload Bus 8 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1600
gpayloadBusFailureToIOSlot14XCONSlot10interconnection Equipment failure Payload Bus 9 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1610
gpayloadBusFailureToIOSlot15XCONSlot10interconnection Equipment failure Payload Bus 10 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1620
gpayloadBusFailureToIOSlot16XCONSlot10interconnection Equipment failure Payload Bus 11 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1630
gpayloadBusFailureToIOSlot17XCONSlot10interconnection Equipment failure Payload Bus 12 Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1640
gtimeSlotInterchangeEquipmentFailureinterconnection Eqpt Time slot interchange eqpt failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1650
gequipmentFailureequipment failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1660
ghighTemperatureHigh Temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1670
ginvalidMACAddressequipment failure Invalid MAC Address
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1680
gboardFailureequipment failure Board Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1690
gdiagnosticFailureequipment failure Diagnostics Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1700
gmediumAccessControlFailureequipment failure Medium Access Control
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1710
gfacilityTerminationEquipmentFailurefacility Termination equipment failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1720
gautomaticLaserShutoffDueToHighTemperatureAutomatic Laser Shutoff Due To High Temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1730
gfailureToReleaseFromProtectionfailure To Release from protection
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1740
greceiverFailurefacility Termination equipment Receiver failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1750
gtransmitFailurefacility Termination equipment Transmit failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1760
gfacilityTerminationEquipmentReceiverMissingfacility Termination equipment Receiver missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1770
gfacilityTerminationEquipmentTransmitterMissingfacility Termination equipment Transmitter missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1780
gfailureToSwitchToProtectionfailure To Switch to protection
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1790
gfailureToSwitchToProtectionRingfailure To Switch to protection Ring
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1800
gfailureToSwitchToProtectionSpanfailure To Switch to protection Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1810
gfailureToSwitchToProtectionPathfailure to Switch to protection Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1820
gfanFailurefailure of cooling fan tray
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1830
gequipmentUnitPlugInequipment unit plug in
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1840
gnePowerFailureAtConnectorNE Power Failure At Connector
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1850
gfuseAlarmpower failure Fuse Alarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1860
gsynchronizationUnitFailuresynchronization unit failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1870
gsynchronizationSwitchingEquipmentFailuresynchronization switching Equipment failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1880
gequipmentUnitUnpluggedequipment unit un plug
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1890
gloopbackloop back
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1900
gds1LoopbackDueToFEACCommandloopback due to FEAC command DS1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1910
gloopbackCommandSentToFarEndDS1loopback Command sent to Far End DS1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1920
gds3LoopbackDueToFEACCommandloopback due to FEAC command DS3
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1930
gds3LoopbackCommandSentToFarEndloopback Command sent to Far End DS3
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1940
gds2LoopbackDueToFarEndCommandloopback due to Far End Command DS2
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1950
gds2LoopbackCommandSentToFarEndloopback Command sent to Far End DS2
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1960
gfacilityLoopbackloop back facility
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1970
gnetworkLoopbackloop back Network
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1980
gterminalLoopbackloop back Terminal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.1990
gmanuallyCausedAbnormalConditionmanually caused abnormal condition
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2000
gethernetBridgeIsNewRootOfSpanningTreenew Root discovered in bridged network
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2010
gethernetBridgeTopologyChangetopology change discovered in bridged network
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2020
gnormalConditionnormal condition
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2030
gembeddedOperationsChannelFailureLinkDownembedded Operations Channel failure link down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2040
gpeerStateMismatchpeer state mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2050
gproceduralErrorprocedural Error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2060
gimproperRemovalImproper Removal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2070
gduplicateNodeIDDuplicate Node ID
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2080
gblsrOutOfSyncBLSR out of sync
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2090
gblsrMultiNodeTableUpdateCompletedBLSR tables resynchronized
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2100
gprotectionUnitNotAvailableprotection unit not available
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2110
gperformanceMonitorThresholdCrossingAlertperformance Monitor Threshold Crossing Alert
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2120
gprotectionSwitchoccurrence of a protection switching event
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2130
grecoveryOrServiceProtectionActionHasBeenInitiatedrecovery or service protection action has been initiated
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2140
gautomaticSystemResetautomatic system Reset
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2150
gautomaticUPSRSwitchCausedByAISautomatic UPSR switch caused by AIS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2160
gautomaticUPSRSwitchCausedByLOPautomatic UPSR switch caused by Lop
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2170
gautomaticUPSRSwitchCausedByUNEQautomatic UPSR switch caused by Uneq
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2180
gautomaticUPSRSwitchCausedByPDIautomatic UPSR switch caused by PDI
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2190
gautomaticUPSRSwitchCausedBySFBERautomatic UPSR switch caused by Sfber
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2200
gautomaticUPSRSwitchCausedBySDBERautomatic UPSR switch caused by Sdber
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2210
gcoldRestartcold Restart
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2220
gforcedSwitchBackToWorkingworking facility or eqpt forced switched to working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2230
gforcedSwitchBackToWorkingRingworking facility or eqpt forced switched to working Ring
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2240
gforcedSwitchBackToWorkingSpanworking facility or eqpt forced switched to working Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2250
gforcedSwitchToProtectionworking facility or eqpt forced switched protection unit
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2260
gforcedSwitchToProtectionRingworking facility or eqpt forced switched protection unit Ring
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2270
gforcedSwitchToProtectionSpanworking facility or eqpt forced switched protection unit Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2280
gworkingFacilityOrEquipmentForcedToSwitchToProtectionPathworking facility or eqpt forced switched protection unit Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2290
ginitializationInitiatedinitialization initiated
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2300
glockoutOfProtectionlockout of Protection
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2310
glockoutOfProtectionRinglockout of Protection Ring
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2320
glockoutOfProtectionSpanlockout of Protection Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2330
glockoutOfProtectionPathlockout of Protection Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2340
glockoutOfWorkinglockout of working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2350
glockoutOfWorkingRinglockout of working Ring
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2360
glockoutOfWorkingSpanlockout of working Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2370
gmanualSystemResetmanual system Reset
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2380
gmanualSwitchToInternalClockmanual switch to internal clock
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2390
gmanualSwitchToPrimaryReferencemanual Switch To Primary refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2400
gmanualSwitchToSecondReferencemanual Switch To Second reference
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2410
gmanualSwitchToThirdReferencemanual Switch To Third refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2420
gmanualSwitchToFourthReferencemanual Switch To Fourth refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2430
gmanualSwitchToFifthReferencemanual Switch To Fifth refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2440
gmanualSwitchToSixthReferencemanual Switch To Sixth refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2450
gmanualSwitchBackToWorkingmanualSwitch of working facility or eqpt to protection Ring
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2460
gmanualSwitchBackToWorkingRingmanualSwitch of working facility or eqpt to protection Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2470
gmanualSwitchBackToWorkingSpanmanualSwitch of working facility or eqpt to protection
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2480
gmanualSwitchToProtectionmanualSwitch of Working facility or eqpt to Protection unit
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2490
gmanualSwitchToProtectionRingworking facility or eqpt manualSwitch to Protection unit Ring
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2500
gmanualSwitchToProtectionSpanworking facility or eqpt manualSwitch to Protection unit Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2510
gmanualSwitchOfWorkingFacilityOrEquipmentToProtectionPathmanualSwitch of working facility or eqpt to Protection Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2520
gpowerfailRestartPowerfail Restart
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2530
gringIsSquelchingTrafficring is squelching traffic
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2540
gsoftwareDownloadInProgresssoftware download in progress
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2550
gswitchToInternalClockSwitch To Internal clock
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2560
gswitchToPrimaryReferenceSwitch To Primary refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2570
gswitchToSecondReferenceSwitch To Second refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2580
gswitchToThirdReferenceSwitch To Third refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2590
gswitchToFourthReferenceSwitch To Fourth refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2600
gswitchToFifthReferenceSwitch To Fifth refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2610
gswitchToSixthReferenceSwitch To Sixth refernce
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2620
gsystemRebootsystem reboot
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2630
gswitchedBackToWorkingSwitched Back To Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2640
gswitchedToProtectionSwitched To Protection
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2650
gwarmRestartwarm Restart
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2660
gringIsInWaitToRestoreStateRing is in Wait To Restore state
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2670
gmanualSwitchRequestManual Switch Request
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2680
gforcedSwitchRequestForced Switch Request
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2690
glockoutSwitchRequestLockout Switch Request
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2700
grmonHistoriesAndAlarmsResetRebootRMON histories and alarms have been reset due to chipset reboot
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2710
grmonThresholdCrossingAlarmCrossing of Falling/Rising Threshold detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2720
galarmsSuppressedByUserCommandAlarms Suppressed By User Command
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2730
galarmsSuppressedForMaintenanceAlarms Suppressed For Maintenance
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2740
gswitchingMatrixModuleFailureSwitching Matrix Module Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2750
glanConnectionPolarityReversedLan Connection Polarity Reversed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2760
gautonomousPMReportMessageInhibitedAutonomous Performance Monitoring Report Message Inhibited
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2780
gioSlotToXCONCommunicationFailureIO Slot To XCON Communication Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2790
gstsPathTraceIdentifierMismatchSTS path trace identifier mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2800
gnePowerFailureAtConnectorANE power failure at connector A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2810
gnePowerFailureAtConnectorBNE power failure at connector B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2820
gfreeMemoryOnCardVeryLowFree memory on the card is very low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2830
gfreeMemoryOnCardNearZeroFree memory on the card is near zero
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2840
gexerciseRequestOnRingExercise Ring.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2850
gexerciseRequestOnSpanExercise Span.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2860
gsquelchingPathSquelching Path:
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2870
gextraTrafficPreemptedExtra Traffic Preempted.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2880
gfarEndLockoutOfWorkingRingFar End Lockout of working - Ring.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2890
gfarEndLockoutOfWorkingSpanFar End Lockout of working - Span.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2900
gfarEndLockoutOfProtectionRingFar End Lockout of Protection - Ring.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2910
gfarEndLockoutOfProtectionAllSpansFar End Lockout of Protection - All Spans.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2920
gfarEndWorkingFacilityForcedToSwitchToProtectionRingFar End Working facility forced to switch to protection unit - Ring.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2930
gfarEndWorkingFacilityForcedToSwitchToProtectionSpanFar End Working facility forced to switch to protection unit - Span.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2940
gfarEndManualSwitchOfWorkingFacilityToProtectionRingFar End Manual Switch of Working facility to Protection unit - Ring.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2950
gfarEndManualSwitchOfWorkingFacilityToProtectionSpanFar End Manual Switch of Working facility to Protection unit - Span.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2960
gfarEndExercisingRingFar End Exercise Ring.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2970
gfarEndExercisingSpanFar End Exercise Span.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2980
gfarEndBERThresholdPassedForSignalFailureRingFar End BER threshold passed for Signal Failure - Ring.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.2990
gfarEndBERThresholdPassedForSignalFailureSpanFar End BER threshold passed for Signal Failure - Span.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3000
gfarEndBERThresholdPassedForSignalDegradeRingFar End BER threshold passed for Signal Degrade - Ring.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3010
gfarEndBERThresholdPassedForSignalDegradeSpanFar End BER threshold passed for Signal Degrade - Span.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3020
gapsChannelFarEndProtectionLineSignalDegradeAPS Channel - Far End Protection Line Signal Degrade.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3030
gringSwitchIsActiveOnTheEastSideRing Switch is active on the East Side.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3040
gringSwitchIsActiveOnTheWestSideRing Switch is active on the West Side.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3050
gspanSwitchIsActiveOnTheEastSideSpan Switch is active on the East Side.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3060
gspanSwitchIsActiveOnTheWestSideSpan Switch is active on the West Side.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3070
guniDirectionalFullPassThroughIsActiveUni-directional Full Pass Through is active.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3080
gbiDirectionalFullPassThroughIsActiveBi-directional Full Pass Through is active.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3090
gkBytesPassThroughIsActiveK Bytes Pass Through is active.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3100
gringIsSegmentedRing is Segmented.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3110
gringTopologyIsUnderConstructionRing Topology is under construction.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3120
glockoutOfProtectionAllSpansLockout of Protection - All Spans.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3130
gfarEndOfFiberIsProvisionedWithDifferentRingIDFar end of fiber is provisioned with different ring ID
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3140
gbothEndsOfFiberProvisionedAsEastOrBothAsWestBoth ends of fiber provisioned as East, or both as West
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3150
gsecurityInvalidLoginUsernameSeeAuditTrailSecurity: Invalid Login Username - See Audit Trail
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3160
gautonomousMessagesInhibitedAutonomous messages inhibited
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3170
gtrafficStormOnLANLANTemporarilyDisabledTraffic storm on LAN. LAN temporarily disabled.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3180
greptdbchgMessagesInhibitedREPT^DBCHG messages of TL1 inhibited
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3190
gsecurityUserIDHasExpiredSecurity: user ID has expired
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3200
gpartialFanFailurePartial Fan Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3210
gforcedSwitchRequestOnRingForce switch request on Ring
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3220
gforcedSwitchRequestOnSpanForce switch request on Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3230
glockoutSwitchRequestOnRingLockout switch request on Ring
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3240
glockoutSwitchRequestOnSpanLockout switch request on Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3250
gmanualSwitchRequestOnRingManual switch request on Ring
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3260
gmanualSwitchRequestOnSpanManual switch request on Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3270
gcommunicationFailurePeerToPeerSlotControlBusAPeer to Peer Slot communication failure - Control Bus A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3280
gcommunicationFailurePeerToPeerSlotControlBusBPeer to Peer Slot communication failure - Control Bus B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3290
gcontrollerAToShelfSlotCommunicationFailureController A to shelf slot communication failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3300
gcontrollerBToShelfSlotCommunicationFailureController B to shelf slot communication failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3310
ginterconnectionEquipmentFailureWorkingPayloadBusInterconnection Equipment Failure - Working Payload Bus
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3320
ginterconnectionEquipmentFailureProtectPayloadBusInterconnection Equipment Failure - Protect Payload Bus
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3330
ginhibitSwitchToProtectRequestOnEquipmentInhibit Switch to Protect Request on equipment
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3340
ginhibitSwitchToWorkingRequestOnEquipmentInhibit Switch to Working Request on equipment
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3350
gberThresholdExceededForSignalDegradeLineBER Threshold exceeded for Signal Degrade - Line
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3360
gberThresholdExceededForSignalDegradePathBER Threshold exceeded for Signal Degrade - Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3370
gberThresholdExceededForSignalFailureLineBER Threshold Exceeded For Signal Failure - Line
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3380
gberThresholdExceededForSignalFailurePathBER Threshold Exceeded For Signal Failure - Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3390
gexercisingRingSuccessfullyExercising Ring Successfully
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3400
gexercisingSpanSuccessfullyExercising Span Successfully
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3410
gspanIsInWaitToRestoreStateSpan is in Wait To Restore state
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3420
gexerciseRequestOnRingFailedExercise Ring Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3430
gexerciseRequestOnSpanFailedExercise Span Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3440
gfarEndLockoutOfProtectionSpanFar end Lockout of Protection Channel - Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3450
gmanufacturingDataMemoryEEPROMFailureManufacturing EEPROM Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3460
greplaceableEquipmentOrUnitIsMissingReplaceable Equipment/Unit Is Missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3470
gsoftwareDownloadFailedSoftware Download Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3480
gextraTrafficPCADroppedExtra Traffic Dropped
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3490
getherTxOversubscribedpkt loss due to oversubscribed xmit
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3500
getherRxOverSubscribedpkt loss due to oversubscribed rcv
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3510
getherTxExcessFlowCtrlexcessive ethernet flow ctl xmited
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3520
getherRxExcessFlowCtrlexcessive ethernet flow ctl recvd
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3530
gtransportLayerFailuretransport layer failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3540
getherTxUnderrunEther hdge internal fifo underrun
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3550
gsynchronizationReferenceFrequencyOutOfBoundsSynchronization reference frequency out of bounds.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3560
gntpOrSntpHostFailureNTP/SNTP Host Failure.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3570
gpeerCardNotRespondingPeer Card Not Responding
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3580
galarmsAndEventsSuppressedForThisObjectAlarms and events suppressed for this object
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3590
gds3FrameFormatMismatchDS3 Frame Format Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3600
gwaitToRestoreWait To Restore
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3610
gextremeHighVoltBatteryAExtreme High Volt Battery A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3620
gextremeLowVoltBatteryAExtreme Low Volt Battery A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3630
gextremeHighVoltBatteryBExtreme High Volt Battery B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3640
gextremeLowVoltBatteryBExtreme Low Volt Battery B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3650
giosConfigCopyFailedIOS config copy failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3660
giosConfigCopyInProgressIOS config copy in progress
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3670
giosConfigCopySuccessIOS Config Copy Success
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3680
gsignalingUnableToSetupCircuitSignaling Unable to setup circuit
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3710
gerrorInStartupConfigError in Startup Config
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3712
gnoStartupConfigNo Startup Config
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3714
gneedToSaveRunningConfigNeed to Save Running Config
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3716
ginvalidAlarmInvalid Alarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3718
grsvpHelloFSMToNeighborDownRSVP Hello FSM to Neighbor down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3720
gsecurityInvalidLoginUsernameSecurity: Invalid Login - Username - See Audit Log
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3722
gdatabaseBackupFailedDatabase Backup Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3724
gdatabaseRestoreFailedDatabase Restore Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3726
glmpHelloFSMToControlChannelDownLMP Hello FSM to Control Channel down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3730
glmpNeighborDiscoveryHasFailedLMP Neighbor Discovery has failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3740
gunauthorizedIncomingSignalingRequestUnauthorized incoming signaling request
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3750
gauditLog80PercentFullAudit Log 80 Percent Full
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3760
gmoduleCommunicationFailureModule Communication Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3762
gauditLog100PercentFullOldestRecordsWillBeLostAudit Log 100 Percent Full - Oldest records will be lost
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3764
gstandbyDatabaseOutOfSyncStandby Database Out of Sync
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3766
gredundantPowerCapabilityLostRedundant Power Capability Lost
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3768
gforcedSwitchToPrimaryReferenceForced Switch To Primary Reference
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3770
gforcedSwitchToSecondReferenceForced Switch To Second Reference
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3780
gforcedSwitchToThirdReferenceForced Switch To Third Reference
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3790
gforcedSwitchToInternalClockForced Switch To Internal Clock
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3800
gindustrialHighTemperatureIndustrial High Temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3805
gimproperMatrixEquipmentInsertedImproper matrix equipment inserted
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3810
geqptProblemOnCarrierOrPIMEQPT problem on Carrier or PIM
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3820
geqptProblemOnPIMOrPPMEQPT problem on PIM or PPM
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.3830
gtimSectionTraceIdentifierMismatchFailureTIM Section - Trace Identifier Mismatch Failure.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4000
gaisMultiplexSectionAlarmIndicationSignalSDH Multiplex Section - Alarm Indication Signal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4010
grdiMultiplexSectionRemoteDefectOrAlarmIndicationSDH Multiplex Section - Remote Defect Indication.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4020
gtimHighOrderTraceIdentifierMismatchFailureSDH High Order - Trace Identifier Mismatch.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4030
gaisAdministrationUnitAlarmIndicationSignalSDH Administration Unit - Alarm Indication Signal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4040
glopAdministrationUnitLossOfPointerSDH Administration Unit - Loss of Pointer.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4050
gslmfUnequippedHighOrderPathUnequippedSDH SLMF High Order - Unequipped Path.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4060
gslmfPLMHighOrderPathLabelMismatchSDH SLMF High Order - Path Label Mismatch.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4070
grdiHighOrderRemoteDefectOrAlarmIndicationSDH High Order - Remote Defect Indication.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4080
glopTributaryUnitLossOfPointerSDH Tributary Unit - Loss of Pointer.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4090
gaisTributaryUnitAlarmIndicationSignalSDH Tributary Unit - Alarm Indication Signal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4100
gslmfUnequippedLowOrderPathUnequippedSDH Low Order - SLMF Unequipped Path.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4110
gslmfPLMLowOrderPathLabelMismatchSDH Low Order - SLMF Path Label Mismatch.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4120
gtimLowOrderTraceIdentifierMismatchFailureSDH Low Order - Trace Identifier Mismatch.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4130
grfiLowOrderRemoteFailureOrAlarmIndicationSDH Low Order - Remote Failure Indication.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4140
gg811PrimaryReferenceClockTraceableG811 - Primary Reference Clock traceable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4150
gg812TransitNodeClockTraceableG812 - Transit Node Clock traceable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4160
gg812LocalNodeClockTraceableG812 - Local Node Clock traceable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4170
gg813SynchronousEquipmentTimingSourceTraceableG813 - Synchronous Equipment Timing Source traceable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4180
ge1LoopbackDueToFEACCommandloopback due to FEAC Command E1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4190
ge1LoopbackCommandSentToFarEndloopback Command sent to Far End E1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4200
ge3LoopbackDueToFEACCommandloopback due to FEAC Command E3
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4210
gfarEndMultipleE1LOSDetectedOnE3far end Multiple E1 LOS detected on E3
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4220
gfarEndE1EqptFailNonServiceAffectingfar end E1 eqpt fail non service affecting
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4230
gfarEndE1EqptFailServiceAffectingfar end E1 eqpt fail service affecting
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4240
gfarEndSingleE1LOSfar end Single E1 LOS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4250
gfarEndE3EqptFailServiceAffectingfar end E3 eqpt fail service affecting
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4260
ge3LoopbackCommandSentToFarEndloopback Command sent to Far End E3
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4270
gfarEndE3EqptFailNonServiceAffectingfar end E3 eqpt fail non service affecting
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4280
glowVoltBatteryALow Volt - Battery A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4290
ghighVoltBatteryAHigh Volt - Battery A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4300
glowVoltBatteryBLow Volt - Battery B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4310
ghighVoltBatteryBHigh Volt - Battery B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4320
gmsspRingOutOfSyncMS-SP ring out of sync
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4330
gmsspMultiNodeTableUpdateCompletedMS-SP ring tables resynchronized
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4340
gautomaticSNCPSwitchCausedByAISautomatic SNCP switch caused by AIS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4350
gautomaticSNCPSwitchCausedByLOPautomatic SNCP switch caused by Lop
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4360
gautomaticSNCPSwitchCausedByUNEQautomatic SNCP switch caused by Uneq
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4370
gautomaticSNCPSwitchCausedByPDIautomatic SNCP switch caused by PDI
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4380
gautomaticSNCPSwitchCausedBySFBERautomatic SNCP switch caused by Sfber
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4390
gautomaticSNCPSwitchCausedBySDBERautomatic SNCP switch caused by Sdber
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4400
gstmConcatenationErrorconcatenation error STM
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4410
ge3IdleConditionidle Condition E3
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4420
gchannelMSSPInconsistentAPSCodechannel MSSP inconsistent APS code
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4430
gchannelMSSPImproperAPSCodeAPSchannel MSSP Improper APS code APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4440
gchannelMSSPNodeIdMismatchAPSchannel MSSP Node Id Mismatch APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4450
gchannelMSSPDefaultKAPSchannel MSSP Default K APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4460
gchannelMSSPConnectionLossAPSchannel MSSP Connection loss APS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4470
gminimumClockTraceableSDHSDH Minimum clock Traceable
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4480
glineIsInWaitToRestoreStateSDHSDH line is in Wait To Restore state
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4490
gberThresholdExceededForSignalDegradeHighOrderBER Threshold exceeded for Signal Degrade - High Order
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4500
gberThresholdExceededForSignalFailureHighOrderBER Threshold exceeded for Signal Failure - High Order
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4510
gberThresholdExceededForSignalDegradeLowOrderBER Threshold exceeded for Signal Degrade - Low Order
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4520
gberThresholdExceededForSignalFailureLowOrderBER Threshold exceeded for Signal Failure - Low Order
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4530
gfailureToSwitchToProtectionHighOrderPathFailure To Switch To Protection - High Order Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4540
gfailureToSwitchToProtectionLowOrderPathFailure To Switch To Protection - Low Order Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4550
glofAdministrationUnitLossOfMultiFrameSDH Administration Unit Loss of Multiframe.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4560
gsdhSpanIsInWaitToRestoreStateSDH span is in Wait To Restore state
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4570
ga8b10bOutOfSync8B10B Out of Sync
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4755
godukPMAlarmIndicationSignalODUk: Alarm Indication Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4760
gotukAlarmIndicationSignalOTUk: Alarm Indication Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4765
gotukSMBackwardDefectIndicationOTUk: Backward Defect Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4770
gfecUncorrectedWordFEC Uncorrected Word
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4780
ggccTerminationFailureGCC Termination Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4785
gotukIncomingAlignmentErrorOTUk: Incoming Alignment Error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4790
godukLockedDefectPMODUk: Locked Defect PM
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4795
glossOfMultiFrameLoss of Multi-Frame
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4800
godukOpenConnectionIndicationODUk: Open Connection Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4805
gpayloadTypeIdentifierMismatchPayload Type Identifier Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4810
godukTrailTraceIdentifierMismatchODUk: Trail Trace Identifier Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4815
gotukTrailTraceIdentifierMismatchOTUk: Trail Trace Identifier Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4820
gequipmentHighLaserBiasEquipment High Laser Bias
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4825
gequipmentHighLaserTempEquipment High Laser Temp
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4830
gequipmentHighLaserPeltierEquipment High Laser Peltier
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4835
gfacilityHighRxPowerFacility High Rx power
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4840
gequipmentHighTxPowerEquipment High Tx power
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4845
gequipmentHighTransceiverVoltageEquipment High Transceiver voltage
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4850
gequipmentLowLaserBiasEquipment Low Laser Bias
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4855
gequipmentLowLaserTempEquipment Low Laser Temp
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4860
gequipmentLowLaserPeltierEquipment Low Laser Peltier
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4865
gfacilityLowRxPowerFacility Low Rx power
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4870
gequipmentLowTxPowerEquipment Low Tx power
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4875
gequipmentLowTransceiverVoltageEquipment Low Transceiver voltage
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4880
gequipmentRxLockedEquipment Rx Locked
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4885
gequipmentSquelchedEquipment Squelched
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4890
gequipmentTxLockedEquipment Tx Locked
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4895
gotukSignalFailureOTUK Signal Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4900
godukSignalFailureODUK Signal Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4905
gotukSignalDegradeOTUK Signal Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4910
godukSignalDegradeODUK Signal Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4915
gpluggablePortMissingPluggable Port missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4920
gpluggablePortRateMismatchPluggable Port rate mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4925
gpluggablePortSecurityCodeMismatchPluggable Port security code mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4930
gtciNotSelectedTci not selected
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4935
gtci1ClockFailureTci 1 Clock Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4940
godukPMBackwardDefectIndicationODUk: PM Backward Defect Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4945
godukTCM1BackwardDefectIndicationODUk: TCM1 Backward Defect Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4950
godukTCM2BackwardDefectIndicationODUk: TCM2 Backward Defect Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4955
gequipmentHighRxTemperatureEquipment High Rx temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4960
gequipmentLowRxTemperatureEquipment Low Rx temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4965
gtci2ClockFailureTci 2 Clock Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4970
gequipmentWavelengthMismatchEquipment Wavelength Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4975
gdspCommunicationFailureDSP Communication Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4980
gdspFailureDSP Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.4985
glaserApproachingEndOfLifeLaser Approaching End of Life
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5000
gcrossconnectLoopbackCross-connect Loopback
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5010
gadminLogoutOfUserAdmin Logout of User
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5020
guserLockedOutUser Locked Out
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5030
gadminLockoutOfUserAdmin Lockout of User
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5040
gadminLockoutClearAdmin Lockout Clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5050
ginvalidLoginUsernameInvalid Login: Username
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5060
gsecurityInvalidLoginPasswordInvalid Login: Password
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5070
gsecurityInvalidLoginLockedOutInvalid Login: Locked Out
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5080
gsecurityInvalidLoginAlreadyLoggedOnInvalid Login: Already Logged On
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5090
gloginOfUserLogin of User
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5100
gautomaticLogoutOfIdleUserAutomatic Logout of IdleUser
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5110
glogoutOfUserLogout of User
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5120
genhancedRemoteFailureIndicationPathServerEnhanced Remote Failure Indication - Path - Server
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5200
genhancedRemoteFailureIndicationPathConnectivityEnhanced Remote Failure Indication - Path - Connectivity
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5210
genhancedRemoteFailureIndicationPathPayloadEnhanced Remote Failure Indication - Path - Payload
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5220
gfirewallHasBeenDisabledFirewall Has Been Disabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5230
gsecurityIntrusionDetPwdSecurity Intrusion - Incorrect Password
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5240
gsecurityIntrusionDetUserSecurity Intrusion - Incorrect Username
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5250
gconnectionEquipmentMismatchConnection Equipment Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5260
gdisableInactiveUserDisable Inactive User
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5270
gdisableInactiveClearDisable Inactive Clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5280
gbatteryFailureBattery Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5290
gextremeHighVoltExtreme High Volt
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5300
gextremeLowVoltExtreme Low Volt
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5310
ghighVoltHigh Volt
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5320
glowVoltLow Volt
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5330
gsuspendUserSuspend User
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5340
gsuspendUserClearSuspend User Clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5350
glineDccTerminationFailureLine DCC Termination Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5360
gmultiplexSectionDccTerminationFailureMultiplex Section DCC Termination Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5370
ggigaBitEthernetOutOfSyncGigaBit Ethernet Out of Sync
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5380
gsequenceMismatchSequence Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5390
glossOfAlignmentLoss of Alignment
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5400
goutOfUseByAdministrativeCommandOut of Use - Administrative Command
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5410
goutOfUseTransportFailureOut of Use - Transport Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5420
gvcatGroupDownVCAT Group Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5430
gvcatGroupDegradedVCAT Group Degraded
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5440
gvcatGroupIncompleteVCAT Group Incomplete
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5450
galarmIndicationSignalInTXAlarm Indication Signal in TX
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5460
gremoteAlarmIndicationInTXRemote Alarm Indication in TX
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5470
gkByteAPSChannelFailureKbyte Channel Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5480
gapsInvalidModeAPS Invalid Mode
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5490
gipAddressAlreadyInUseWithinTheSameDccAreaIP address already in use within the same DCC Area
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5500
gnodeNameInUseWithinTheSameDccAreaNode name already in use within the same DCC Area
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5510
grearPanelEthernetLinkRemovedRear Panel Ethernet Link Removed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5520
gmanualSwitchToProtectResultedInNoTrafficSwitchManual Switch To Protect Resulted in No Traffic Switch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5530
gmanualSwitchBackToWorkingResultedInNoTrafficSwitchManual Switch Back To Working Resulted in No Traffic Switch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5540
gforcedSwitchToProtectResultedInNoTrafficSwitchForced Switch To Protection Resulted in No Traffic Switch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5550
gforcedSwitchBackToWorkingResultedInNoTrafficSwitchForced Switch Back To Working Resulted in No Traffic Switch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5560
gduplicateSerialNumberDetectedOnAPluggableEntityDuplicate Serial number detected on a pluggable entity
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5570
glossOfSignalForOpticalChannelIncoming Payload Signal Absent
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5600
gencapsulationMismatchPathEncapsulation Type Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5610
gencapsulationMismatchVTEncapsulation Mismatch - VT
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5620
gencapsulationMismatchHighOrderPathEncapsulation Mismatch High Order - Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5630
gencapsulationMismatchLowOrderPathEncapsulation Mismatch Low Order - Path
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5640
ggfpUserPayloadMismatchGFP User Payload Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5650
ggfpFibreChannelDistanceExtensionMismatchGFP Fibre Channel Distance Extension Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5660
ggfpFibreChannelDistanceExtensionBufferStarvationGFP Fibre Channel Distance Extension Buffer Starvation
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5670
ggfpFibreChannelDistanceExtensionCreditStarvationFibre Channel Distance Extension Credit Starvation
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5680
gautomaticWdmAnsFinishedAutomatic WDM ANS Finished
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5690
ggfpClientSignalFailDetectedGFP Client Signal Fail Detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5700
ggfpLossOfFrameDelineationGFP Loss of Frame Delineation
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5710
ggfpExtensionHeaderMismatchGFP Extension Header Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5730
gincomingOverheadSignalAbsentLoss of Signal for Overhead
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5740
gopticalSafetyRemoteInterlockOnOptical Safety Remote Interlock On
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5750
gautomaticPowerControlCorrectionSkippedAutomatic Power Control Correction Skipped
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5770
gapcCannotSetValueDueToRangeLimitsAPC cannot set value due to range limits
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5780
glcasVcgMemberTxSideInAddStateLCAS VCG Member Tx Side In ADD State
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5790
gfarEndManualSwitchBackToWorkingSpanFar End Manual Switch Back to Working - Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5800
gfarEndForcedSwitchBackToWorkingSpanFar End Forced Switch Back to Working - Span
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5810
guniversalTransponderModuleHardwareFailureUniversal Transponder Module Hardware Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5820
guniversalTransponderModuleCommunicationFailureUniversal Transponder Module Communication Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5830
gpluginModuleRangeSettingsMismatchPlug-in Module Range Settings Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5840
glcasVcgMemberTxSideInDnuStateLCAS VCG Member Tx Side In DNU State
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5850
glcasControlWordCrcCheckFailureLCAS Control Word CRC Check Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5860
glcasVcgMemberRxSideInFailStateLCAS VCG Member Rx Side In FAIL State
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5870
gsignalLossOnDataInterfaceSignal Loss on Data Interface
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5880
gsynchronizationLossOnDataInterfaceSynchronization Loss on Data Interface
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5890
gportFAILPORT FAIL
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5900
gunreachablePortTargetPowerUnreachable port target power
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5910
gportAddPowerDegradeLowPort Add Power Degrade Low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5920
gportAddPowerDegradeHighPort Add Power Degrade High
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5930
gportAddPowerFailLowPort Add Power Fail Low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5940
gportAddPowerFailHighPort Add Power Fail High
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.5950
gautomaticPowerControlTerminatedOnManualRequestAutomatic Power Control Terminated on Manual request
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6000
goduk1AlarmIndicationSignalODUk-1: Alarm Indication Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6010
goduk2AlarmIndicationSignalODUk-2: Alarm Indication Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6020
goduk3AlarmIndicationSignalODUk-3: Alarm Indication Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6030
goduk4AlarmIndicationSignalODUk-4: Alarm Indication Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6040
gtemperatureReadingMismatchBetweenSCCardsTemperature Reading Mismatch Between SC Cards
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6050
gvoltageReadingMismatchBetweenSCCardsVoltage Reading Mismatch Between SC Cards
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6060
galarmsSuppressedonOutOfGroupVcatMemberAlarms Suppressed on Out-Of-Group VCAT Member
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6070
gblsrSoftwareVersionMismatchBLSR Software Version Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6080
goptimized1Plus1ApsPrimaryFacilityOptimized 1+1 APS Primary Facility
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6090
goptimized1Plus1ApsPrimarySectionMismatchOptimized 1+1 APS Primary Section Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6100
goptimized1Plus1ApsInvalidPrimarySectionOptimized 1+1 APS Invalid Primary Section
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6110
gcompositeClockHighLineVoltageComposite Clock High Line Voltage
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6120
gberThresholdExceededForSignalDegradeVtBER Threshold Exceeded For Signal Degrade - VT
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6130
gberThresholdExceededForSignalFailureVtBER Threshold Exceeded For Signal Failure - VT
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6140
gspanLengthOutOfRangeSpan Length Out of Range
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6150
gidleSignalConditionIdle Signal Condition
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6170
gidleSignalConditionInTxIdle Signal Condition in TX
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6180
gvtPathTraceIdentifierMismatchVT Path Trace Identifier Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6190
glossOfFrameInTXLoss of Frame in TX
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6200
gprovisioningMismatchProvisioning Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6210
gsectionTraceIdentifierMismatchSection Trace Identifier Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6220
gregeneratorSectionTraceIdentifierMismatchRegenerator Section Trace Identifier Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6230
gswitchingMatrixModuleFailureWorkingSwitching Matrix Module Failure - Working
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6240
gswitchingMatrixModuleFailureProtectSwitching Matrix Module Failure - Protect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6250
gslotCommunicationDisabledSlot Communication Disabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6260
gsessionTimeLimitExpiredSession Time Limit Expired
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6270
guserPasswordChangeRequiredUser Password Change Required
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6280
gisisAdjacencyFailureISIS Adjacency Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6290
gmsspSoftwareVersionMismatchMSSP Software Version Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6300
gremoteAuthenticationFailSeeAuditLogRemote Authentication Fail - See Audit Log
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6310
gillegalRouteAdditionToNetworkIllegal route addition to the Network
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6320
gringIsSquelchingStsTrafficRing Is Squelching STS Traffic
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6330
gringIsSquelchingVtTrafficRing Is Squelching VT Traffic
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6340
garchiveOfAuditLogFailedArchival of Audit Log Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6350
grprWrappedRPR Wrapped
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6360
gshelfCommunicationFailureShelf Communication Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6370
gduplicatedShelfIdentifierDuplicated Shelf Identifier
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6380
gsoftwareMismatchSoftware Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6390
glmpFailureLMP Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6400
gopticalTerminationIncompleteOptical Termination Incomplete
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6410
gforwardDefectIndicationForward Defect Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6420
gpayloadMissingIndicationPayload Missing Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6430
gspanMeasurementCannotBePerformedSpan loss not checked
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6440
gringIsSquelchingHighOrderTrafficRing Is Squelching Higher Order Traffic
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6450
gringIsSquelchingLowOrderTrafficRing Is Squelching Lower Order Traffic
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6460
gbadPacketCountExceedsThresholdBad Packet Count Exceeds Threshold
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6470
glinkLayerKeepAliveFailureLink Layer Keep-Alive Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6480
gautonegotiationRemoteFailureIndicationAuto-Negotiation Remote Failure Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6490
gtrailSignalFailTrail Signal Fail
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6500
gds1LoopbackCommandSentToFarEndDS1 Loopback Command Sent To Far End
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6510
gmultiplexSectionSignalDegradedMultiplex Section - Signal Degraded
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6520
gmultiplexSectionExcessiveErrorsMultiplex Section - Excessive Errors
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6530
ghighOrderPathSignalDegradedHigh Order Path - Signal Degraded
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6540
ghighOrderPathExcessiveErrorsHigh Order Path - Excessive Errors
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6550
glowOrderPathSignalDegradedLow Order Path - Signal Degraded
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6560
glowOrderPathExcessiveErrorsLow Order Path - Excessive Errors
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6570
gregeneratorSectionDccTerminationFailureRegenerator Section - DCC Termination Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6580
gnetworkMemoryPoolLowNetwork Memory Pool Low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6590
gospfRoutingTableOverflowOSPF Routing Table Overflow
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6600
gautoLaserShutdownDisabledAuto Laser Shutdown Disabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6610
gwavelengthOutOfLockWavelength Out of Lock
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6620
grprProtectionIsActiveRPR Protection Is Active
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6630
gmaxRPRStationNumberExceededMax RPR Station Number Exceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6640
grprProtectionConfigurationMismatchedRPR Protection Configuration Mismatched
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6650
greservedBandwidthLinkRateExceededOnRinglet0Reserved Bandwidth Link Rate Exceeded On Ringlet0
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6660
greservedBandwidthLinkRateExceededOnRinglet1Reserved Bandwidth Link Rate Exceeded On Ringlet1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6670
grprInterfaceInPassThroughModeRPR Interface In Pass Through Mode
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6680
grprPeerNodeIsMissingRPR Peer Node is Missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6690
grprRiFailureRPR RI Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6700
grprSignalFailureRPR Signal Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6710
grprSignalDegradeRPR Signal Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6720
ginterlinkFailureADM Peer Cards Interlink Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6730
gapcWrongGainAPC Wrong Gain Set Point
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6740
grprSpanMismatchRPR Span Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6750
gefmRemoteFaultIndicationCriticalEventEFM Remote Fault Indication- Critical Event
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6760
gefmRemoteFaultIndicationDyingGaspEFM Remote Fault Indication- Dying Gasp
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6770
gefmRemoteFaultIndicationLinkFaultEFM Remote Fault Indication- Link Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6780
gefmLinkMonitoringErroredSymbolPeriodEventEFM Link Monitoring- Errored Symbol Period Event
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6790
gefmLinkMonitoringErroredFrameEventEFM Link Monitoring- Errored Frame Event
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6800
gefmLinkMonitoringErroredFramePeriodEventEFM Link Monitoring- Errored Frame Period Event
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6810
gefmLinkMonitoringErroredFrameSecondsSummaryEFM Link Monitoring- Errored Frame Seconds Summary
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6820
gefmRemoteLoopbackRequestFailedEFM Remote Loopback Request Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6830
gfastAutomaticProtectionSwitchingFast Automatic Protection Switching
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6840
gfastAutomaticProtectionSwitchingConfigMismatchFast Automatic Protection Switching Config Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6850
glcasSinkGroupErrorLCAS Sink Group Error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6860
glcasVcgMemberRxSideInDnuStateLCAS VCG Member Rx Side In DNU State
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6870
gfcDistanceExtFuncNotEstablishedFibre Channel Distance Extension Function Not Established
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6880
gnonCiscoPPMInsertedNon Cisco PPM Inserted
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6890
gunqualifiedPPMInsertedUnqualified PPM Inserted
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6900
gftaMismatchFanTray Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6910
gcardPortsUnableToProvideProtectionCard/Ports Unable To Provide Protection
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6920
glmpSignalDegradeLMP Signal Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6930
glmpSignalFailureLMP Signal Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6940
gfrontPortLinkLossTCC Front Port Link Loss
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6960
gbertEnblBERT Enabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6970
gbertSyncFailBERT Synchronization Status Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6975
gworkQueueFullWork Queue Full
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.6980
gequipmentPowerFailureAtConnectorAEquipment Power Failure At Connector A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7000
gequipmentPowerFailureAtConnectorBEquipment Power Failure At Connector B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7005
gequipmentPowerFailureAtReturnConnectorAEquipment Power Failure At Return Connector A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7010
gequipmentPowerFailureAtReturnConnectorBEquipment Power Failure At Return Connector B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7015
gloginFailThresholdExceededInvalid login attempt threshold exceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7020
gconnectionIdMismatchOnMatrixAConnection ID mismatch on Matrix A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7025
gconnectionIdMismatchOnMatrixBConnection ID mismatch on Matrix B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7030
gmanufacturingEepromFailureManufacturing data memory (EEPROM) failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7035
gequipmentFailureHighTemperatureEquipment failure high temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7040
glaserBiasCurrentHighLaser bias current high
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7045
ghighLaserTemperatureHigh laser temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7050
gbridgeAndRollHasOccurredBridge and Roll Has Occurred
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7055
gbridgeAndRollIsPendingAValidSignalBridge and Roll is Pending a Valid Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7060
gairFlowAir Flow
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7065
gpartialFanFailurePartsFailurePartial Fan Failure - Parts Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7070
gunprotectedSyncronizationEquipmentUnprotected Synchronization Equipment
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7075
gunprotectedMatrixEquipmentUnprotected Matrix Equipment
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7080
gmatrixEquipmentUnavailableMatrix Equipment Unavailable
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7085
gcontrolBusFailureTscAControl Bus Failure - TSC A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7090
gcontrolBusFailureTscBControl Bus Failure - TSC B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7095
gpayloadBusFailureMatrixAPayload Bus Failure - Matrix A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7100
gpayloadBusFailureMatrixBPayload Bus Failure - Matrix B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7105
gmatrixOperationSuspendedMatrix Operation Suspended
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7110
gclockFailureTscClock Module Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7115
gpayloadLoopbackLoopback - Payload
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7120
gdccChannelLossDCC Channel Loss
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7125
greptPmMsgInhibitedAutonomous PM Report Message Inhibited
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7130
gloopbackCrsLoopback - Cross Connect
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7135
gsyncRefFreqOutOfBoundSynchronization Reference Frequency Out Of Bounds
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7140
gsystemUpgradeInProgressSystem Upgrade In Progress
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7145
geqptFailToBootEquipment Fails To Boot
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7150
geqptPowerFailureEquipment Power Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7155
gclockBusFailureTscAClock Bus Failure - Shelf Controller A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7160
gclockBusFailureTscBClock Bus Failure - Shelf Controller B
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7165
gpowerFuseFailurePower Fuse Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7170
gcontrolCommunicationsEquipmentFailureControl Communication Equipment Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7175
gdifferentSoftwareVersionDifferent Software Version
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7180
gospfHelloFailOSPF Hello Fail
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7185
gclockModuleFrequencyMismatchClock Module Frequency Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7190
getherPortSwitchTSC switched to alternate ethernet port
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7195
gopenIOSlotsOpen IO Slot(s)
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7200
gequipmentBootInProgressEquipment boot in-progress.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7205
glossOfClockFromMateShelfControllerLoss of Clock from mate Shelf Controller
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7210
gvirtualLanAlarmIndicationSignalVirtual Lan AIS
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7225
gdcuLossFailureDCU Loss Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7230
gochncMaintenanceOCHNC Maintenance
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7235
gramanLaserShutdownRaman Laser Shutdown
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7240
glosOfRamanSignalLoss Of Raman Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7245
gmcastMacTableFullMulticast Mac Address Table Full
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7250
gmulticastMacAddressAliasingMulticast Mac Address Aliasing
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7255
gramanPwrProtOnRaman Power Protection On
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7260
gcppPeerNotRespondingCPP Peer Not Responding
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7265
gvoaControlLoopDisableDueToExcessiveCounterPropagationLightVOA Control Loop Disable Due To Excessive Counter-Propagation Light
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7275
gwizardIsRunningWizard Is Running
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7280
gramanGainNotReachedRaman Span Not Tuned
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7285
gpprForwardDefectIndicationpprForwardDefectIndication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7295
gpprBackwardDefectIndicationpprBackwardDefectIndication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7300
gpprCoordinatedMaintenancepprCoordinatedMaintenance
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7305
gpprTriggerThresholdBERExceededpprTriggerThresholdBERExceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7310
glocalFaultLocal Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7315
gremoteFaultRemote Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7320
gefmRemoteLoopbackConfiguredEFM Port In Remote Loopback
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7325
gefmPeerMissingEFM Link To Peer Missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7330
geqptDegradeEquipment Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7335
gexcessiveBackPropagationExcessive Back Propagation
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7340
gremoteMaintenanceEndPointIsDownCFM Remote Maintenance End Point Is Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7345
gcrossConnectedCFMServiceCross Connected CFM Service
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7350
gcfmLoopCFM Loop
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7355
gcfmConfigurationErrorCFM Configuration Error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7360
goutOfChannelGroupBundleOut Of Channel Group Bundle
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7365
grepNeighborAdjacencyFailureREP Neighbor Adjacency Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7370
grepLinkFlappingREP Link Flapping
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7375
gfaultInREPSegmentFault In REP Segment
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7380
gprimaryREPEdgePortElectedPrimary REP Edge Port Elected
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7385
gsecondaryREPEdgePortElectedSecondary REP Edge Port Elected
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7390
gstcnREPGeneratedSTCN REP Generated
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7395
gvlbREPActivatedVLB REP Activated
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7400
gvlbREPTriggerSoakingDelayActiveVLB REP Trigger Soaking Delay Active
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7405
gwanSynclossEthernet Syncloss On WAN Port
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7410
glaserShutdownDueToWavelengthDriftlaser Shutdown Due To Wavelength Drift
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7415
gmanualLaserRestartmanual Laser Restart
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7420
glaserShutdownDueToNonCiscoPPMInsertedlaserShutdownDueToNonCiscoPPMInserted
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7425
gethernetOSCTerminationFailureEthernet OSC Termination Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7430
gsoftwareSignatureVerificationFailedsoftware Signature Verification Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7445
gprotectVolumeSoftwareSignatureVerificationFailedProtect Volume Software Signature Verification
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7450
gactiveVolumeSoftwareSignatureVerificationFailedActive Software Signature Verification Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7455
gpeerPortClientSignalFailDetectedPeer Port Client Signal Fail Detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7460
gchannelShutdownDuetoWavelengthDriftChannel Shutdown Due to Wavelength Drift
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7465
gusbWriteFailureUSB Write Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7475
gusbSyncInProgressUSB Sync in Progress
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7480
gautoSensingUnableToDetectValidPayloadAuto-Sensing Unable To Detect Valid Payload
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7485
gpayloadAutoSensingInProgressPayload Auto-Sensing In Progress
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7490
ggfpClientSignalFailDetectedDueToSiglossGFP Client Signal Fail Detected Due To Sigloss
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7495
ggfpClientSignalFailDetectedDueToSynclossGFP Client Signal Fail Detected Due To Syncloss
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7500
gpmdDegradePMD Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7510
gstandbyTccNEClockIsInternalClockStandby Tcc NE Clock Is Internal Clock
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7515
gchromaticDispersionValuechromatic Dispersion Value
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7520
gpacketTransportServiceFailedpacketTransportServiceFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7525
gsatellitePanelDiscoveryFailureSatellite Panel Discovery Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7530
gsatellitePanelActiveLinkFailureSatellite Panel Active Link Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7535
gsatellitePanelCommunicationFailureSatellite Panel Communication Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7540
gsatellitePanelImproperConfigurationSatellite Panel Improper Configuration
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7545
gsatellitePanelFanMismatchOfEquipmentAndAttributesSatellite Panel Fan Mismatch Of Equipment And Attributes
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7550
gsatellitePanelFanFailureSatellite Panel Fan Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7555
gsatellitePanelPartialFanFailureSatellite Panel Partial Fan Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7560
gsatellitePanelFANManufacturingDataMemoryEEPROMFailureSatellite Panel FAN Manufacturing Data Memory (EEPROM) Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7565
gsatellitePanelFANUnitIsMissingSatellite Panel FAN Unit Is Missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7570
gsatellitePanelIndustrialHighTemperatureSatellite Panel Industrial High Temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7575
gsatellitePanelHighTemperatureSatellite Panel High Temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7580
gsatellitePanelBatteryFailureASatellite Panel Battery Failure A
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7585
gplannedSwitchOverPlanned Switch Over
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7590
gprotectionCardConfigurationMismatchprotection Card Configuration Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7595
grouterProcessorSwitchOverRouter Processor Switch Over
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7600
grunningLowOnResourcesRunning Low On Resources
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7605
gnoMoreResourcesAreAvailableNo More Resources Are Available
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7610
gesmcFailureESMC Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7615
glicenseWillExpireWithin24Hourslicense Will Expire Within 24 Hours
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7620
glicenseWillExpireAnytimeAfter1DayButBefore14Dayslicense Will Expire Anytime After 1Day But Before 14 Days
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7625
glicenseIsExpiredlicense Is Expired
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7630
glicenseCountViolationlicense Count Violation
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7635
gtemporaryLicenseIsInUseTemporary License Is In Use
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7640
gevaluationLicenseIsInUseEvaluation License Is In Use
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7645
glicenseIsMissingLicense Is Missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7650
gpseudowireDownPseudowire Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7655
gworkingPseudowireControlPlaneDownWorking Pseudowire Control Plane Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7660
gprotectPseudowireControlPlaneDownProtect Pseudowire Control Plane Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7665
gworkingPseudowireConnectivityCheckDownWorking Pseudowire Connectivity Check Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7670
gprotectPseudowireConnectivityCheckDownProtect Pseudowire Connectivity Check Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7675
gpseudowireTrafficSwitchedToPretectionPseudowire Traffic Switched To Pretection
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7680
gworkingPseudowireLocalAcTxPortFaultWorking Pseudowire Local AcTx Port Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7685
gprotectPseudowireLocalAcTxPortFaultProtect Pseudowire Local AcTx Port Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7690
gworkingPseudowireLocalAcRxPortFaultWorking Pseudowire Local AcRx Port Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7695
gprotectPseudowireLocalAcRxPortFaultProtect Pseudowire Local AcRx Port Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7700
gworkingPseudowireRemoteAcTxPortFaultWorking Pseudowire Remote AcTx Port Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7705
gprotectPseudowireRemoteAcTxPortFaultProtect Pseudowire Remote AcTx Port Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7710
gworkingPseudowireRemoteAcRxPortFaultworking Pseudowire Remote AcRx Port Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7715
gprotectPseudowireRemoteAcRxPortFaultProtect Pseudowire Remote AcRx Port Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7720
gslaThresholdCrossAlertSLA Threshold Cross Alert
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7725
gprotectLocalPseudowireNotForwardingProtect Local Pseudowire Not Forwarding
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7730
gworkingRemotePseudowireNotForwardingWorking Remote Pseudowire Not Forwarding
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7735
gprotectRemotePseudowireNotForwardingProtect Remote Pseudowire Not Forwarding
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7740
gtpTunnelDownTp Tunnel Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7745
gworkingLabelSwitchedPathDownWorking Label Switched Path Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7750
gprotectLabelSwitchedPathDownProtect Label Switched Path Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7755
gworkingLabelSwitchedPathAlarmIndicationSignalWorking Label Switched Path Alarm Indication Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7760
gprotectLabelSwitchedPathAlarmIndicationSignalProtect Label Switched Path Alarm Indication Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7765
gworkingLabelSwitchedPathRemoteDefectIndicationWorking Label Switched Path Remote Defect Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7770
gprotectLabelSwitchedPathRemoteDefectIndicationProtect Label Switched Path Remote Defect Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7775
gbidirectionalForwardDetectionDownBidirectional Forward Detection Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7780
gtpTrafficSwitchedFromWorkingToProtectionTp Traffic Switched From Working To Protection
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7785
gworkingTpLockoutworking Tp Lockout
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7790
gprotectTpLockoutprotect Tp Lockout
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7795
gethernetFlowPointFailedEthernet Flow Point Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7800
gteTunnelDownTE Tunnel Down
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7805
gmacSystemLimitReachedMAC System Limit Reached
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7810
gmacBridgeDomainLimitReachedMAC Bridge Domain Limit Reached
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7815
gautoSensingDisabledAuto Sense Disabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7820
gsmBackwardIncomingAlignmentErrorSM Backward Incoming Alignment Error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7825
gresourceAllocationFailedResource Allocation Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7830
glossOfDFBSignalloss Of DFB Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7835
gworkingLabelSwitchedPathLinkDownIndicationWorking Label Switched Path Link Down Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7840
gprotectLabelSwitchedPathLinkDownIndicationProtect Label Switched Path Link Down Indication
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7845
gworkingLabelSwitchedPathLockReportWorking Label Switched Path Lock Report
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7850
gprotectLabelSwitchedPathLockReportProtect Label Switched Path Lock Report
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7855
gsatellitePanelBatteryFailureBsatellite Panel Battery FailureB
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7860
ghighBitErrorRateHigh Bit Error Rate
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7865
gbackPanelFacilityLoopbackBack Panel Facility Loopback
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7870
gbackPanelTerminalLoopbackBack Panel Terminal Loopback
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7875
gtrunkPayloadTypeMismatchPayload Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7880
ginvalidMuxponderConfigurationInvalid Muxponder Configuration
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7885
gcoolingProfileMismatchCooling Profile Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7890
gtrunkOduAlarmIndicationSignalTrunk ODU: Alarm Indication Signal
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7895
gcompanionCardMissingCompanion Card Missing
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7900
gcontrolPlaneUnverifiedClearedAlarmsPresentControl Plane Unverified Cleared Alarms Present
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7905
gpowerConsumptionLimitHasCrossedPower Consumption Limit Has Crossed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7910
gmasterKeyExchangeFailedMaster Key Exchange Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7915
gunitHighTemperatureUnit High Temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7930
goverTemperatureUnitProtectedOver Temperature Unit Protected
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7935
gseqMismatchCountSequence Mismatch Count
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7945
gkeyProgramOnAlteraFpgaFailedKey Program On Altera FPGA Failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7960
gduplicateNodeControllerDetectedDuplicate Node Controller Detected
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7970
grestorationInProgRestoration in Progress
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7975
gramanPumpsCalibrationProcedureIsRunningRaman Calibration Running
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7980
gramanPumpsCalibrationIsScheduledToRunInTheNextMinutesRaman Calibration Pending
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.7985
godukTCM1AlarmIndicationSignalODUk Alarm Indication Signal TCM1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13100
godukTCM2AlarmIndicationSignalODUk Alarm Indication Signal TCM2
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13105
godukLockedDefectTCM1ODUk Locked Defect - TCM1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13110
godukLockedDefectTCM2ODUk Locked Defect - TCM2
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13115
gotukLossOfFrameOTUk: Loss Of Frame
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13120
godukOpenConnectionIndicationTCM1ODUk Open Connection Indication TCM1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13125
godukOpenConnectionIndicationTCM2ODUk Open Connection Indication TCM2
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13130
godukTrailTraceIdentifierMismatchTCM1ODUk Trail Trace Identifier Mismatch TCM1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13135
godukTrailTraceIdentifierMismatchTCM2ODUk Trail Trace Identifier Mismatch TCM2
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13140
godukSignalFailureTCM1ODUk Signal Failure - TCM1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13145
godukSignalFailureTCM2ODUk Signal Failure - TCM2
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13150
godukSignalDegradeTCM1ODUk Signal Degrade - TCM1
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13155
godukSignalDegradeTCM2ODUk Signal Degrade - TCM2
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13160
glossOfChannelLoss of Channel
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13165
gfecMismatchFEC Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13170
gtimSectionMonitorTraceIdentifierMismatchFailureTIM Section Monitor - Trace Identifier Mismatch Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13175
gautomaticLaserShutdownAutomatic Laser Shutdown
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13180
gshutterInsertionLossVariationDegradeLowShutter Insertion Loss Variation Degrade Low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13200
gopticalChannelDeactivationFailureOptical Channel de-activation failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13205
gshutterInsertionLossVariationDegradeHighShutter Insertion Loss Variation Degrade High
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13210
gnetworkTopologyIncompleteNetwork Topology Incomplete
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13215
gpluginModuleCommunicationFailurePlug-in Module Communication Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13220
gopticalNetworkTypeMismatchOptical Network Type Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13225
gopticalPowerDegradeLowLaser Power Degrade Low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13230
gautomaticPowerControlFailureAutomatic Power Control Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13235
gopticalPowerDegradeHighOptical Power Degrade High
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13240
gautomaticPowerControlDisabledAutomatic Power Control Disabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13245
gopticalPowerFailureLowOptical Power Failure Low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13250
gringIdMismatchRing Id Mismatch
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13255
gopticalPowerFailureHighOptical Power Failure High
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13260
glossOfContinuityLoss Of Continuity
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13270
gvariableOpticalAttenuatorDegradeLowVariable Optical Attenuator Degrade Low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13280
gvariableOpticalAttenuatorDegradeHighVariable Optical Attenuator Degrade High
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13290
gvariableOpticalAttenuatorFailureLowVariable Optical Attenuator Failure Low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13300
gvariableOpticalAttenuatorFailureHighVariable Optical Attenuator Failure High
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13310
glaserBiasDegradeLaser Bias Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13320
glaserBiasFailureaser Bias Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13330
glaserTemperatureDegradeLaser Temperature Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13340
gopticalAmplifierGainDegradeLowOptical Amplifier Gain Degrade Low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13350
gopticalAmplifierGainDegradeHighOptical Amplifier Gain Degrade High
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13360
gopticalAmplifierGainFailureLowOptical Amplifier Gain Failure Low
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13370
gopticalAmplifierGainFailureHighOptical Amplifier Gain Failure High
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13380
gopticalChannelConnectionFailureOptical Channel connection failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13390
gopticalChannelIncompleteOptical Channel Incomplete
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13395
gopticalChannelActivationFailureOptical Channel activation failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13400
glaserAutoPowerReductionLaser Auto Power Reduction
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13410
gcaseTemperatureDegradeCase Temperature Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13420
gfiberTemperatureDegradeFiber Temperature Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13430
gshutterOpenShutter Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13440
gawgTemperatureDegradeAWG Temperature Degrade
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13450
gawgTemperatureFailureAWG Temperature Failure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13460
gawgOverTemperatureAWG Over-Temperature
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13470
gopticalAmplifierInitializationOptical Amplifier Initialization
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13480
gawgWarmUpAWG Warm Up
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13490
gincSiglossIncoming Signal Loss on Fibre Channel Interface
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13510
gincSynclossIncoming Synchronization Loss on Fibre Channel Interface
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13515
gincGfpOutOfFrameOut Of Frame Detected by GFP Receiver
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13520
gincGfpSigLossClient Signal Loss Frames Detected by GFP Receiver
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13525
gincGfpSyncLossClient Sychronization Loss Frames Detected by GFP Receiver
NOTIFICATION-TYPE
.1.3.6.1.4.1.3607.2.20.0.13530
cerentConformanceThis node is created for compliance. Has objects as required by the RFCs
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.5.10
cerentGenericGroupsAll the objects and events are grouped under this for conformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.5.10.10
cerentComplianceThe compliance statements for Cisco ONS 15327, 15310.
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.5.10.20