Home/Catalog/CISCO-UNIFIED-COMPUTING-VNIC-MIB

CISCO-UNIFIED-COMPUTING-VNIC-MIB

AI MIB Summary

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

MIB representation of the Cisco Unified Computing System VNIC management information model package
Main OID:
cucsVnicObjects.1.3.6.1.4.1.9.9.719.1.53
1161
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

1161 total
Object Name
cucsVnicObjectsMIB representation of the Cisco Unified Computing System VNIC management information model package
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.719.1.53
cucsVnicBootTargetTableCisco UCS vnic:BootTarget managed object table
SEQUENCE OF CucsVnicBootTargetEntry
.1.3.6.1.4.1.9.9.719.1.53.1
cucsVnicBootTargetEntryEntry for the cucsVnicBootTargetTable table.
CucsVnicBootTargetEntry
.1.3.6.1.4.1.9.9.719.1.53.1.1
cucsVnicBootTargetInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.1.1.1
cucsVnicBootTargetDnCisco UCS vnic:BootTarget:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.1.1.2
cucsVnicBootTargetRnCisco UCS vnic:BootTarget:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.1.1.3
cucsVnicBootTargetLunCisco UCS vnic:BootTarget:lun managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.1.1.4
cucsVnicBootTargetWwnCisco UCS vnic:BootTarget:wwn managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.1.1.5
cucsVnicDefBehTableCisco UCS vnic:DefBeh managed object table
SEQUENCE OF CucsVnicDefBehEntry
.1.3.6.1.4.1.9.9.719.1.53.2
cucsVnicDefBehEntryEntry for the cucsVnicDefBehTable table.
CucsVnicDefBehEntry
.1.3.6.1.4.1.9.9.719.1.53.2.1
cucsVnicDefBehInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.2.1.1
cucsVnicDefBehDnCisco UCS vnic:DefBeh:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.2.1.2
cucsVnicDefBehRnCisco UCS vnic:DefBeh:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.2.1.3
cucsVnicDefBehActionCisco UCS vnic:DefBeh:action managed object propertyro
CucsVnicDefaultAction (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.2.1.4
cucsVnicDefBehNwTemplNameCisco UCS vnic:DefBeh:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.2.1.5
cucsVnicDefBehTypeCisco UCS vnic:DefBeh:type managed object propertyro
CucsVnicDefBehType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.2.1.6
cucsVnicDefBehDescrCisco UCS vnic:DefBeh:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.2.1.7
cucsVnicDefBehIntIdCisco UCS vnic:DefBeh:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.2.1.8
cucsVnicDefBehNameCisco UCS vnic:DefBeh:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.2.1.9
cucsVnicDefBehPolicyLevelCisco UCS vnic:DefBeh:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.2.1.10
cucsVnicDefBehPolicyOwnerCisco UCS vnic:DefBeh:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.2.1.11
cucsVnicDynamicConTableCisco UCS vnic:DynamicCon managed object table
SEQUENCE OF CucsVnicDynamicConEntry
.1.3.6.1.4.1.9.9.719.1.53.3
cucsVnicDynamicConEntryEntry for the cucsVnicDynamicConTable table.
CucsVnicDynamicConEntry
.1.3.6.1.4.1.9.9.719.1.53.3.1
cucsVnicDynamicConInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.3.1.1
cucsVnicDynamicConDnCisco UCS vnic:DynamicCon:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.3.1.2
cucsVnicDynamicConRnCisco UCS vnic:DynamicCon:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.3.1.3
cucsVnicDynamicConAdaptorProfileNameCisco UCS vnic:DynamicCon:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.3.1.4
cucsVnicDynamicConDescrCisco UCS vnic:DynamicCon:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.3.1.5
cucsVnicDynamicConDynamicEthCisco UCS vnic:DynamicCon:dynamicEth managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.3.1.6
cucsVnicDynamicConIntIdCisco UCS vnic:DynamicCon:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.3.1.7
cucsVnicDynamicConMtuCisco UCS vnic:DynamicCon:mtu managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.3.1.8
cucsVnicDynamicConNameCisco UCS vnic:DynamicCon:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.3.1.9
cucsVnicDynamicConNamingPrefixCisco UCS vnic:DynamicCon:namingPrefix managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.3.1.10
cucsVnicDynamicConProtectionCisco UCS vnic:DynamicCon:protection managed object propertyro
CucsVnicDynamicConReqProtection (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.3.1.11
cucsVnicDynamicConPolicyLevelCisco UCS vnic:DynamicCon:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.3.1.12
cucsVnicDynamicConPolicyOwnerCisco UCS vnic:DynamicCon:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.3.1.13
cucsVnicDynamicConPolicyTableCisco UCS vnic:DynamicConPolicy managed object table
SEQUENCE OF CucsVnicDynamicConPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.4
cucsVnicDynamicConPolicyEntryEntry for the cucsVnicDynamicConPolicyTable table.
CucsVnicDynamicConPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.4.1
cucsVnicDynamicConPolicyInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.4.1.1
cucsVnicDynamicConPolicyDnCisco UCS vnic:DynamicConPolicy:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.4.1.2
cucsVnicDynamicConPolicyRnCisco UCS vnic:DynamicConPolicy:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.4.1.3
cucsVnicDynamicConPolicyAdaptorProfileNameCisco UCS vnic:DynamicConPolicy:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.4.1.4
cucsVnicDynamicConPolicyDescrCisco UCS vnic:DynamicConPolicy:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.4.1.5
cucsVnicDynamicConPolicyDynamicEthCisco UCS vnic:DynamicConPolicy:dynamicEth managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.4.1.6
cucsVnicDynamicConPolicyIntIdCisco UCS vnic:DynamicConPolicy:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.4.1.7
cucsVnicDynamicConPolicyMtuCisco UCS vnic:DynamicConPolicy:mtu managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.4.1.8
cucsVnicDynamicConPolicyNameCisco UCS vnic:DynamicConPolicy:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.4.1.9
cucsVnicDynamicConPolicyNamingPrefixCisco UCS vnic:DynamicConPolicy:namingPrefix managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.4.1.10
cucsVnicDynamicConPolicyProtectionCisco UCS vnic:DynamicConPolicy:protection managed object propertyro
CucsVnicDynamicConReqProtection (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.4.1.11
cucsVnicDynamicConPolicyPolicyLevelCisco UCS vnic:DynamicConPolicy:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.4.1.12
cucsVnicDynamicConPolicyPolicyOwnerCisco UCS vnic:DynamicConPolicy:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.4.1.13
cucsVnicDynamicIdUniverseTableCisco UCS vnic:DynamicIdUniverse managed object table
SEQUENCE OF CucsVnicDynamicIdUniverseEntry
.1.3.6.1.4.1.9.9.719.1.53.5
cucsVnicDynamicIdUniverseEntryEntry for the cucsVnicDynamicIdUniverseTable table.
CucsVnicDynamicIdUniverseEntry
.1.3.6.1.4.1.9.9.719.1.53.5.1
cucsVnicDynamicIdUniverseInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.5.1.1
cucsVnicDynamicIdUniverseDnCisco UCS vnic:DynamicIdUniverse:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.5.1.2
cucsVnicDynamicIdUniverseRnCisco UCS vnic:DynamicIdUniverse:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.5.1.3
cucsVnicDynamicIdUniverseDescrCisco UCS vnic:DynamicIdUniverse:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.5.1.4
cucsVnicDynamicIdUniverseIntIdCisco UCS vnic:DynamicIdUniverse:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.5.1.5
cucsVnicDynamicIdUniverseNameCisco UCS vnic:DynamicIdUniverse:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.5.1.6
cucsVnicDynamicIdUniversePolicyLevelCisco UCS vnic:DynamicIdUniverse:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.5.1.7
cucsVnicDynamicIdUniversePolicyOwnerCisco UCS vnic:DynamicIdUniverse:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.5.1.8
cucsVnicDynamicProviderTableCisco UCS vnic:DynamicProvider managed object table
SEQUENCE OF CucsVnicDynamicProviderEntry
.1.3.6.1.4.1.9.9.719.1.53.6
cucsVnicDynamicProviderEntryEntry for the cucsVnicDynamicProviderTable table.
CucsVnicDynamicProviderEntry
.1.3.6.1.4.1.9.9.719.1.53.6.1
cucsVnicDynamicProviderInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.6.1.1
cucsVnicDynamicProviderDnCisco UCS vnic:DynamicProvider:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.6.1.2
cucsVnicDynamicProviderRnCisco UCS vnic:DynamicProvider:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.6.1.3
cucsVnicDynamicProviderNameCisco UCS vnic:DynamicProvider:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.6.1.4
cucsVnicDynamicProviderEpTableCisco UCS vnic:DynamicProviderEp managed object table
SEQUENCE OF CucsVnicDynamicProviderEpEntry
.1.3.6.1.4.1.9.9.719.1.53.7
cucsVnicDynamicProviderEpEntryEntry for the cucsVnicDynamicProviderEpTable table.
CucsVnicDynamicProviderEpEntry
.1.3.6.1.4.1.9.9.719.1.53.7.1
cucsVnicDynamicProviderEpInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.7.1.1
cucsVnicDynamicProviderEpDnCisco UCS vnic:DynamicProviderEp:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.7.1.2
cucsVnicDynamicProviderEpRnCisco UCS vnic:DynamicProviderEp:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.7.1.3
cucsVnicDynamicProviderEpChassisIdCisco UCS vnic:DynamicProviderEp:chassisId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.7.1.4
cucsVnicDynamicProviderEpPortIdCisco UCS vnic:DynamicProviderEp:portId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.7.1.5
cucsVnicDynamicProviderEpSlotIdCisco UCS vnic:DynamicProviderEp:slotId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.7.1.6
cucsVnicDynamicProviderEpSwitchIdCisco UCS vnic:DynamicProviderEp:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.7.1.7
cucsVnicEthLifTableCisco UCS vnic:EthLif managed object table
SEQUENCE OF CucsVnicEthLifEntry
.1.3.6.1.4.1.9.9.719.1.53.8
cucsVnicEthLifEntryEntry for the cucsVnicEthLifTable table.
CucsVnicEthLifEntry
.1.3.6.1.4.1.9.9.719.1.53.8.1
cucsVnicEthLifInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.8.1.1
cucsVnicEthLifDnCisco UCS vnic:EthLif:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.8.1.2
cucsVnicEthLifRnCisco UCS vnic:EthLif:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.8.1.3
cucsVnicEthLifAddrCisco UCS vnic:EthLif:addr managed object propertyro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.8.1.4
cucsVnicEthLifNameCisco UCS vnic:EthLif:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.8.1.5
cucsVnicEthLifNicDnCisco UCS vnic:EthLif:nicDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.8.1.6
cucsVnicEthLifOwnerCisco UCS vnic:EthLif:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.8.1.7
cucsVnicEthLifSwitchIdCisco UCS vnic:EthLif:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.8.1.8
cucsVnicEthLifTypeCisco UCS vnic:EthLif:type managed object propertyro
CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.8.1.9
cucsVnicEthLifVnicDnCisco UCS vnic:EthLif:vnicDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.8.1.10
cucsVnicEtherTableCisco UCS vnic:Ether managed object table
SEQUENCE OF CucsVnicEtherEntry
.1.3.6.1.4.1.9.9.719.1.53.9
cucsVnicEtherEntryEntry for the cucsVnicEtherTable table.
CucsVnicEtherEntry
.1.3.6.1.4.1.9.9.719.1.53.9.1
cucsVnicEtherInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.1
cucsVnicEtherDnCisco UCS vnic:Ether:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.2
cucsVnicEtherRnCisco UCS vnic:Ether:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.3
cucsVnicEtherAdaptorProfileNameCisco UCS vnic:Ether:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.4
cucsVnicEtherAddrCisco UCS vnic:Ether:addr managed object propertyro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.9.1.5
cucsVnicEtherAdminVconCisco UCS vnic:Ether:adminVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.6
cucsVnicEtherBootDevCisco UCS vnic:Ether:bootDev managed object propertyro
CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.7
cucsVnicEtherConfigStateCisco UCS vnic:Ether:configState managed object propertyro
CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.8
cucsVnicEtherEquipmentDnCisco UCS vnic:Ether:equipmentDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.9
cucsVnicEtherFltAggrCisco UCS vnic:Ether:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.9.1.10
cucsVnicEtherIdentPoolNameCisco UCS vnic:Ether:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.11
cucsVnicEtherInstTypeCisco UCS vnic:Ether:instType managed object propertyro
CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.12
cucsVnicEtherMtuCisco UCS vnic:Ether:mtu managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.9.1.13
cucsVnicEtherNameCisco UCS vnic:Ether:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.14
cucsVnicEtherNwCtrlPolicyNameCisco UCS vnic:Ether:nwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.15
cucsVnicEtherNwTemplNameCisco UCS vnic:Ether:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.16
cucsVnicEtherOperAdaptorProfileNameCisco UCS vnic:Ether:operAdaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.17
cucsVnicEtherOperIdentPoolNameCisco UCS vnic:Ether:operIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.18
cucsVnicEtherOperNwCtrlPolicyNameCisco UCS vnic:Ether:operNwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.19
cucsVnicEtherOperNwTemplNameCisco UCS vnic:Ether:operNwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.20
cucsVnicEtherOperOrderCisco UCS vnic:Ether:operOrder managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.9.1.21
cucsVnicEtherOperQosPolicyNameCisco UCS vnic:Ether:operQosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.22
cucsVnicEtherOperSpeedCisco UCS vnic:Ether:operSpeed managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.9.1.23
cucsVnicEtherOperStatsPolicyNameCisco UCS vnic:Ether:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.24
cucsVnicEtherOperVconCisco UCS vnic:Ether:operVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.25
cucsVnicEtherOrderCisco UCS vnic:Ether:order managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.9.1.26
cucsVnicEtherOwnerCisco UCS vnic:Ether:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.27
cucsVnicEtherPinToGroupNameCisco UCS vnic:Ether:pinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.28
cucsVnicEtherQosPolicyNameCisco UCS vnic:Ether:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.29
cucsVnicEtherStatsPolicyNameCisco UCS vnic:Ether:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.30
cucsVnicEtherSwitchIdCisco UCS vnic:Ether:switchId managed object propertyro
CucsVnicEtherBaseSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.31
cucsVnicEtherTypeCisco UCS vnic:Ether:type managed object propertyro
CucsVnicEtherType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.32
cucsVnicEtherOperPinToGroupNameCisco UCS vnic:Ether:operPinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.33
cucsVnicEtherConfigQualifierCisco UCS vnic:Ether:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.34
cucsVnicEtherDynamicIdCisco UCS vnic:Ether:dynamicId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.9.1.35
cucsVnicEtherPfDnCisco UCS vnic:Ether:pfDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.36
cucsVnicEtherVirtualizationPreferenceCisco UCS vnic:Ether:virtualizationPreference managed object propertyro
CucsVnicVirtualizationPreferenceType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.37
cucsVnicEtherAdminHostPortCisco UCS vnic:Ether:adminHostPort managed object propertyro
CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.39
cucsVnicEtherOperHostPortCisco UCS vnic:Ether:operHostPort managed object propertyro
CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.40
cucsVnicEtherPropAclCisco UCS vnic:Ether:propAcl managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.9.1.41
cucsVnicEtherPurposeCisco UCS vnic:Ether:purpose managed object propertyro
CucsAdaptorPurpose (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.42
cucsVnicEtherAdminCdnNameCisco UCS vnic:Ether:adminCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.43
cucsVnicEtherOperCdnNameCisco UCS vnic:Ether:operCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.44
cucsVnicEtherCdnSourceCisco UCS vnic:Ether:cdnSource managed object propertyro
CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.45
cucsVnicEtherCdnPropInSyncCisco UCS vnic:Ether:cdnPropInSync managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.9.1.46
cucsVnicEtherRedundancyPairTypeCisco UCS vnic:Ether:redundancyPairType managed object propertyro
CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.47
cucsVnicEtherRedundancyPeerCisco UCS vnic:Ether:redundancyPeer managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.9.1.48
cucsVnicEtherIfTableCisco UCS vnic:EtherIf managed object table
SEQUENCE OF CucsVnicEtherIfEntry
.1.3.6.1.4.1.9.9.719.1.53.10
cucsVnicEtherIfEntryEntry for the cucsVnicEtherIfTable table.
CucsVnicEtherIfEntry
.1.3.6.1.4.1.9.9.719.1.53.10.1
cucsVnicEtherIfInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.1
cucsVnicEtherIfDnCisco UCS vnic:EtherIf:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.2
cucsVnicEtherIfRnCisco UCS vnic:EtherIf:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.3
cucsVnicEtherIfAddrCisco UCS vnic:EtherIf:addr managed object propertyro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.10.1.4
cucsVnicEtherIfDefaultNetCisco UCS vnic:EtherIf:defaultNet managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.10.1.5
cucsVnicEtherIfNameCisco UCS vnic:EtherIf:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.6
cucsVnicEtherIfOperStateCisco UCS vnic:EtherIf:operState managed object propertyro
CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.7
cucsVnicEtherIfOwnerCisco UCS vnic:EtherIf:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.8
cucsVnicEtherIfSwitchIdCisco UCS vnic:EtherIf:switchId managed object propertyro
CucsVnicEtherBaseIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.9
cucsVnicEtherIfTypeCisco UCS vnic:EtherIf:type managed object propertyro
CucsVnicAEtherIfType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.10
cucsVnicEtherIfVnetCisco UCS vnic:EtherIf:vnet managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.10.1.11
cucsVnicEtherIfOperVnetDnCisco UCS vnic:EtherIf:operVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.12
cucsVnicEtherIfOperVnetNameCisco UCS vnic:EtherIf:operVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.13
cucsVnicEtherIfConfigQualifierCisco UCS vnic:EtherIf:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.14
cucsVnicEtherIfFltAggrCisco UCS vnic:EtherIf:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.10.1.15
cucsVnicEtherIfPubNwIdCisco UCS vnic:EtherIf:pubNwId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.10.1.17
cucsVnicEtherIfSharingCisco UCS vnic:EtherIf:sharing managed object propertyro
CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.18
cucsVnicEtherIfPropAclCisco UCS vnic:EtherIf:propAcl managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.10.1.19
cucsVnicEtherIfOperPrimaryVnetDnCisco UCS vnic:EtherIf:operPrimaryVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.20
cucsVnicEtherIfOperPrimaryVnetNameCisco UCS vnic:EtherIf:operPrimaryVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.10.1.21
cucsVnicFcTableCisco UCS vnic:Fc managed object table
SEQUENCE OF CucsVnicFcEntry
.1.3.6.1.4.1.9.9.719.1.53.11
cucsVnicFcEntryEntry for the cucsVnicFcTable table.
CucsVnicFcEntry
.1.3.6.1.4.1.9.9.719.1.53.11.1
cucsVnicFcInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.1
cucsVnicFcDnCisco UCS vnic:Fc:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.2
cucsVnicFcRnCisco UCS vnic:Fc:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.3
cucsVnicFcAdaptorProfileNameCisco UCS vnic:Fc:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.4
cucsVnicFcAddrCisco UCS vnic:Fc:addr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.11.1.5
cucsVnicFcAdminVconCisco UCS vnic:Fc:adminVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.6
cucsVnicFcBootDevCisco UCS vnic:Fc:bootDev managed object propertyro
CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.7
cucsVnicFcConfigStateCisco UCS vnic:Fc:configState managed object propertyro
CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.8
cucsVnicFcEquipmentDnCisco UCS vnic:Fc:equipmentDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.9
cucsVnicFcFltAggrCisco UCS vnic:Fc:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.11.1.10
cucsVnicFcIdentPoolNameCisco UCS vnic:Fc:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.11
cucsVnicFcInstTypeCisco UCS vnic:Fc:instType managed object propertyro
CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.12
cucsVnicFcMaxDataFieldSizeCisco UCS vnic:Fc:maxDataFieldSize managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.11.1.13
cucsVnicFcNameCisco UCS vnic:Fc:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.14
cucsVnicFcNdAddrCisco UCS vnic:Fc:nodeAddr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.11.1.15
cucsVnicFcNwTemplNameCisco UCS vnic:Fc:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.16
cucsVnicFcOperAdaptorProfileNameCisco UCS vnic:Fc:operAdaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.17
cucsVnicFcOperIdentPoolNameCisco UCS vnic:Fc:operIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.18
cucsVnicFcOperNwTemplNameCisco UCS vnic:Fc:operNwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.19
cucsVnicFcOperOrderCisco UCS vnic:Fc:operOrder managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.11.1.20
cucsVnicFcOperQosPolicyNameCisco UCS vnic:Fc:operQosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.21
cucsVnicFcOperSpeedCisco UCS vnic:Fc:operSpeed managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.11.1.22
cucsVnicFcOperStatsPolicyNameCisco UCS vnic:Fc:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.23
cucsVnicFcOperVconCisco UCS vnic:Fc:operVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.24
cucsVnicFcOrderCisco UCS vnic:Fc:order managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.11.1.25
cucsVnicFcOwnerCisco UCS vnic:Fc:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.26
cucsVnicFcPersBindCisco UCS vnic:Fc:persBind managed object propertyro
CucsVnicFcBasePersBind (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.27
cucsVnicFcPersBindClearCisco UCS vnic:Fc:persBindClear managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.11.1.28
cucsVnicFcPinToGroupNameCisco UCS vnic:Fc:pinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.29
cucsVnicFcQosPolicyNameCisco UCS vnic:Fc:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.30
cucsVnicFcStatsPolicyNameCisco UCS vnic:Fc:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.31
cucsVnicFcSwitchIdCisco UCS vnic:Fc:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.32
cucsVnicFcTypeCisco UCS vnic:Fc:type managed object propertyro
CucsVnicFcBaseType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.33
cucsVnicFcOperPinToGroupNameCisco UCS vnic:Fc:operPinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.34
cucsVnicFcConfigQualifierCisco UCS vnic:Fc:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.35
cucsVnicFcAdminHostPortCisco UCS vnic:Fc:adminHostPort managed object propertyro
CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.37
cucsVnicFcOperHostPortCisco UCS vnic:Fc:operHostPort managed object propertyro
CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.38
cucsVnicFcAdminCdnNameCisco UCS vnic:Fc:adminCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.39
cucsVnicFcOperCdnNameCisco UCS vnic:Fc:operCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.40
cucsVnicFcCdnSourceCisco UCS vnic:Fc:cdnSource managed object propertyro
CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.41
cucsVnicFcCdnPropInSyncCisco UCS vnic:Fc:cdnPropInSync managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.11.1.42
cucsVnicFcRedundancyPairTypeCisco UCS vnic:Fc:redundancyPairType managed object propertyro
CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.43
cucsVnicFcRedundancyPeerCisco UCS vnic:Fc:redundancyPeer managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.11.1.44
cucsVnicFcIfTableCisco UCS vnic:FcIf managed object table
SEQUENCE OF CucsVnicFcIfEntry
.1.3.6.1.4.1.9.9.719.1.53.12
cucsVnicFcIfEntryEntry for the cucsVnicFcIfTable table.
CucsVnicFcIfEntry
.1.3.6.1.4.1.9.9.719.1.53.12.1
cucsVnicFcIfInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.1
cucsVnicFcIfDnCisco UCS vnic:FcIf:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.2
cucsVnicFcIfRnCisco UCS vnic:FcIf:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.3
cucsVnicFcIfInitiatorCisco UCS vnic:FcIf:initiator managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.12.1.4
cucsVnicFcIfNameCisco UCS vnic:FcIf:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.5
cucsVnicFcIfOperStateCisco UCS vnic:FcIf:operState managed object propertyro
CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.6
cucsVnicFcIfOwnerCisco UCS vnic:FcIf:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.7
cucsVnicFcIfSwitchIdCisco UCS vnic:FcIf:switchId managed object propertyro
CucsVnicAFcIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.8
cucsVnicFcIfTypeCisco UCS vnic:FcIf:type managed object propertyro
CucsVnicAFcIfType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.9
cucsVnicFcIfVnetCisco UCS vnic:FcIf:vnet managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.12.1.10
cucsVnicFcIfOperVnetDnCisco UCS vnic:FcIf:operVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.11
cucsVnicFcIfOperVnetNameCisco UCS vnic:FcIf:operVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.12
cucsVnicFcIfConfigQualifierCisco UCS vnic:FcIf:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.13
cucsVnicFcIfPubNwIdCisco UCS vnic:FcIf:pubNwId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.12.1.15
cucsVnicFcIfSharingCisco UCS vnic:FcIf:sharing managed object propertyro
CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.16
cucsVnicFcIfOperPrimaryVnetDnCisco UCS vnic:FcIf:operPrimaryVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.17
cucsVnicFcIfOperPrimaryVnetNameCisco UCS vnic:FcIf:operPrimaryVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.12.1.18
cucsVnicFcLifTableCisco UCS vnic:FcLif managed object table
SEQUENCE OF CucsVnicFcLifEntry
.1.3.6.1.4.1.9.9.719.1.53.13
cucsVnicFcLifEntryEntry for the cucsVnicFcLifTable table.
CucsVnicFcLifEntry
.1.3.6.1.4.1.9.9.719.1.53.13.1
cucsVnicFcLifInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.13.1.1
cucsVnicFcLifDnCisco UCS vnic:FcLif:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.13.1.2
cucsVnicFcLifRnCisco UCS vnic:FcLif:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.13.1.3
cucsVnicFcLifAddrCisco UCS vnic:FcLif:addr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.13.1.4
cucsVnicFcLifNameCisco UCS vnic:FcLif:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.13.1.5
cucsVnicFcLifNicDnCisco UCS vnic:FcLif:nicDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.13.1.6
cucsVnicFcLifOwnerCisco UCS vnic:FcLif:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.13.1.7
cucsVnicFcLifSwitchIdCisco UCS vnic:FcLif:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.13.1.8
cucsVnicFcLifTypeCisco UCS vnic:FcLif:type managed object propertyro
CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.13.1.9
cucsVnicFcLifVnicDnCisco UCS vnic:FcLif:vnicDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.13.1.10
cucsVnicFcNodeTableCisco UCS vnic:FcNode managed object table
SEQUENCE OF CucsVnicFcNodeEntry
.1.3.6.1.4.1.9.9.719.1.53.14
cucsVnicFcNodeEntryEntry for the cucsVnicFcNodeTable table.
CucsVnicFcNodeEntry
.1.3.6.1.4.1.9.9.719.1.53.14.1
cucsVnicFcNodeInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.14.1.1
cucsVnicFcNodeDnCisco UCS vnic:FcNode:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.14.1.2
cucsVnicFcNodeRnCisco UCS vnic:FcNode:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.14.1.3
cucsVnicFcNodeAddrCisco UCS vnic:FcNode:addr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.14.1.4
cucsVnicFcNodeFltAggrCisco UCS vnic:FcNode:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.14.1.5
cucsVnicFcNodeIdentPoolNameCisco UCS vnic:FcNode:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.14.1.6
cucsVnicFcNodeOperIdentPoolNameCisco UCS vnic:FcNode:operIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.14.1.7
cucsVnicFcNodeMaxDerivableWWPNCisco UCS vnic:FcNode:maxDerivableWWPN managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.14.1.8
cucsVnicFcNodeOwnerCisco UCS vnic:FcNode:owner managed object propertyro
CucsVnicFcNodeOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.14.1.9
cucsVnicFcOEIfTableCisco UCS vnic:FcOEIf managed object table
SEQUENCE OF CucsVnicFcOEIfEntry
.1.3.6.1.4.1.9.9.719.1.53.15
cucsVnicFcOEIfEntryEntry for the cucsVnicFcOEIfTable table.
CucsVnicFcOEIfEntry
.1.3.6.1.4.1.9.9.719.1.53.15.1
cucsVnicFcOEIfInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.1
cucsVnicFcOEIfDnCisco UCS vnic:FcOEIf:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.2
cucsVnicFcOEIfRnCisco UCS vnic:FcOEIf:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.3
cucsVnicFcOEIfInitiatorCisco UCS vnic:FcOEIf:initiator managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.15.1.4
cucsVnicFcOEIfNameCisco UCS vnic:FcOEIf:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.5
cucsVnicFcOEIfOperStateCisco UCS vnic:FcOEIf:operState managed object propertyro
CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.6
cucsVnicFcOEIfOwnerCisco UCS vnic:FcOEIf:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.7
cucsVnicFcOEIfSwitchIdCisco UCS vnic:FcOEIf:switchId managed object propertyro
CucsVnicAFcIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.8
cucsVnicFcOEIfTypeCisco UCS vnic:FcOEIf:type managed object propertyro
CucsVnicAFcIfType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.9
cucsVnicFcOEIfVnetCisco UCS vnic:FcOEIf:vnet managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.15.1.10
cucsVnicFcOEIfConfigQualifierCisco UCS vnic:FcOEIf:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.11
cucsVnicFcOEIfOperVnetDnCisco UCS vnic:FcOEIf:operVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.13
cucsVnicFcOEIfOperVnetNameCisco UCS vnic:FcOEIf:operVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.14
cucsVnicFcOEIfPubNwIdCisco UCS vnic:FcOEIf:pubNwId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.15.1.15
cucsVnicFcOEIfSharingCisco UCS vnic:FcOEIf:sharing managed object propertyro
CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.16
cucsVnicFcOEIfOperPrimaryVnetDnCisco UCS vnic:FcOEIf:operPrimaryVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.17
cucsVnicFcOEIfOperPrimaryVnetNameCisco UCS vnic:FcOEIf:operPrimaryVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.15.1.18
cucsVnicIPv4DhcpTableCisco UCS vnic:IPv4Dhcp managed object table
SEQUENCE OF CucsVnicIPv4DhcpEntry
.1.3.6.1.4.1.9.9.719.1.53.16
cucsVnicIPv4DhcpEntryEntry for the cucsVnicIPv4DhcpTable table.
CucsVnicIPv4DhcpEntry
.1.3.6.1.4.1.9.9.719.1.53.16.1
cucsVnicIPv4DhcpInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.16.1.1
cucsVnicIPv4DhcpDnCisco UCS vnic:IPv4Dhcp:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.16.1.2
cucsVnicIPv4DhcpRnCisco UCS vnic:IPv4Dhcp:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.16.1.3
cucsVnicIPv4DhcpAddrCisco UCS vnic:IPv4Dhcp:addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.16.1.4
cucsVnicIPv4DhcpDefGwCisco UCS vnic:IPv4Dhcp:defGw managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.16.1.5
cucsVnicIPv4DhcpSubnetCisco UCS vnic:IPv4Dhcp:subnet managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.16.1.6
cucsVnicIPv4DnsTableCisco UCS vnic:IPv4Dns managed object table
SEQUENCE OF CucsVnicIPv4DnsEntry
.1.3.6.1.4.1.9.9.719.1.53.17
cucsVnicIPv4DnsEntryEntry for the cucsVnicIPv4DnsTable table.
CucsVnicIPv4DnsEntry
.1.3.6.1.4.1.9.9.719.1.53.17.1
cucsVnicIPv4DnsInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.17.1.1
cucsVnicIPv4DnsDnCisco UCS vnic:IPv4Dns:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.17.1.2
cucsVnicIPv4DnsRnCisco UCS vnic:IPv4Dns:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.17.1.3
cucsVnicIPv4DnsAddrCisco UCS vnic:IPv4Dns:addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.17.1.4
cucsVnicIPv4DnsDefGwCisco UCS vnic:IPv4Dns:defGw managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.17.1.5
cucsVnicIPv4DnsPrefCisco UCS vnic:IPv4Dns:pref managed object propertyro
CucsVnicIPv4DnsPref (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.17.1.6
cucsVnicIPv4DnsSubnetCisco UCS vnic:IPv4Dns:subnet managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.17.1.7
cucsVnicIPv4IfTableCisco UCS vnic:IPv4If managed object table
SEQUENCE OF CucsVnicIPv4IfEntry
.1.3.6.1.4.1.9.9.719.1.53.18
cucsVnicIPv4IfEntryEntry for the cucsVnicIPv4IfTable table.
CucsVnicIPv4IfEntry
.1.3.6.1.4.1.9.9.719.1.53.18.1
cucsVnicIPv4IfInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.1
cucsVnicIPv4IfDnCisco UCS vnic:IPv4If:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.2
cucsVnicIPv4IfRnCisco UCS vnic:IPv4If:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.3
cucsVnicIPv4IfAddrCisco UCS vnic:IPv4If:addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.4
cucsVnicIPv4IfNameCisco UCS vnic:IPv4If:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.5
cucsVnicIPv4IfOperStateCisco UCS vnic:IPv4If:operState managed object propertyro
CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.6
cucsVnicIPv4IfOwnerCisco UCS vnic:IPv4If:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.7
cucsVnicIPv4IfSwitchIdCisco UCS vnic:IPv4If:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.8
cucsVnicIPv4IfTypeCisco UCS vnic:IPv4If:type managed object propertyro
CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.9
cucsVnicIPv4IfVnetCisco UCS vnic:IPv4If:vnet managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.18.1.10
cucsVnicIPv4IfConfigQualifierCisco UCS vnic:IPv4If:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.11
cucsVnicIPv4IfOperVnetDnCisco UCS vnic:IPv4If:operVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.13
cucsVnicIPv4IfOperVnetNameCisco UCS vnic:IPv4If:operVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.14
cucsVnicIPv4IfPubNwIdCisco UCS vnic:IPv4If:pubNwId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.18.1.15
cucsVnicIPv4IfSharingCisco UCS vnic:IPv4If:sharing managed object propertyro
CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.16
cucsVnicIPv4IfPropAclCisco UCS vnic:IPv4If:propAcl managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.18.1.17
cucsVnicIPv4IfOperPrimaryVnetDnCisco UCS vnic:IPv4If:operPrimaryVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.18
cucsVnicIPv4IfOperPrimaryVnetNameCisco UCS vnic:IPv4If:operPrimaryVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.18.1.19
cucsVnicIPv4StaticRouteTableCisco UCS vnic:IPv4StaticRoute managed object table
SEQUENCE OF CucsVnicIPv4StaticRouteEntry
.1.3.6.1.4.1.9.9.719.1.53.19
cucsVnicIPv4StaticRouteEntryEntry for the cucsVnicIPv4StaticRouteTable table.
CucsVnicIPv4StaticRouteEntry
.1.3.6.1.4.1.9.9.719.1.53.19.1
cucsVnicIPv4StaticRouteInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.19.1.1
cucsVnicIPv4StaticRouteDnCisco UCS vnic:IPv4StaticRoute:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.19.1.2
cucsVnicIPv4StaticRouteRnCisco UCS vnic:IPv4StaticRoute:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.19.1.3
cucsVnicIPv4StaticRouteAddrCisco UCS vnic:IPv4StaticRoute:addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.19.1.4
cucsVnicIPv4StaticRouteDefGwCisco UCS vnic:IPv4StaticRoute:defGw managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.19.1.5
cucsVnicIPv4StaticRouteGwAddrCisco UCS vnic:IPv4StaticRoute:gwAddr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.19.1.6
cucsVnicIPv4StaticRouteGwSubnetCisco UCS vnic:IPv4StaticRoute:gwSubnet managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.19.1.7
cucsVnicIPv4StaticRouteSubnetCisco UCS vnic:IPv4StaticRoute:subnet managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.19.1.8
cucsVnicIpV4PooledAddrTableCisco UCS vnic:IpV4PooledAddr managed object table
SEQUENCE OF CucsVnicIpV4PooledAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.20
cucsVnicIpV4PooledAddrEntryEntry for the cucsVnicIpV4PooledAddrTable table.
CucsVnicIpV4PooledAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.20.1
cucsVnicIpV4PooledAddrInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.20.1.1
cucsVnicIpV4PooledAddrDnCisco UCS vnic:IpV4PooledAddr:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.20.1.2
cucsVnicIpV4PooledAddrRnCisco UCS vnic:IpV4PooledAddr:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.20.1.3
cucsVnicIpV4PooledAddrAddrCisco UCS vnic:IpV4PooledAddr:addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.20.1.4
cucsVnicIpV4PooledAddrDefGwCisco UCS vnic:IpV4PooledAddr:defGw managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.20.1.5
cucsVnicIpV4PooledAddrNameCisco UCS vnic:IpV4PooledAddr:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.20.1.6
cucsVnicIpV4PooledAddrSubnetCisco UCS vnic:IpV4PooledAddr:subnet managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.20.1.7
cucsVnicIpV4PooledAddrOperNameCisco UCS vnic:IpV4PooledAddr:operName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.20.1.8
cucsVnicIpV4PooledAddrPrimDnsCisco UCS vnic:IpV4PooledAddr:primDns managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.20.1.9
cucsVnicIpV4PooledAddrSecDnsCisco UCS vnic:IpV4PooledAddr:secDns managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.20.1.10
cucsVnicIpV4ProfDerivedAddrTableCisco UCS vnic:IpV4ProfDerivedAddr managed object table
SEQUENCE OF CucsVnicIpV4ProfDerivedAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.21
cucsVnicIpV4ProfDerivedAddrEntryEntry for the cucsVnicIpV4ProfDerivedAddrTable table.
CucsVnicIpV4ProfDerivedAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.21.1
cucsVnicIpV4ProfDerivedAddrInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.21.1.1
cucsVnicIpV4ProfDerivedAddrDnCisco UCS vnic:IpV4ProfDerivedAddr:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.21.1.2
cucsVnicIpV4ProfDerivedAddrRnCisco UCS vnic:IpV4ProfDerivedAddr:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.21.1.3
cucsVnicIpV4ProfDerivedAddrAddrCisco UCS vnic:IpV4ProfDerivedAddr:addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.21.1.4
cucsVnicIpV4ProfDerivedAddrDefGwCisco UCS vnic:IpV4ProfDerivedAddr:defGw managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.21.1.5
cucsVnicIpV4ProfDerivedAddrSubnetCisco UCS vnic:IpV4ProfDerivedAddr:subnet managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.21.1.6
cucsVnicIpV4StaticAddrTableCisco UCS vnic:IpV4StaticAddr managed object table
SEQUENCE OF CucsVnicIpV4StaticAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.22
cucsVnicIpV4StaticAddrEntryEntry for the cucsVnicIpV4StaticAddrTable table.
CucsVnicIpV4StaticAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.22.1
cucsVnicIpV4StaticAddrInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.22.1.1
cucsVnicIpV4StaticAddrDnCisco UCS vnic:IpV4StaticAddr:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.22.1.2
cucsVnicIpV4StaticAddrRnCisco UCS vnic:IpV4StaticAddr:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.22.1.3
cucsVnicIpV4StaticAddrAddrCisco UCS vnic:IpV4StaticAddr:addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.22.1.4
cucsVnicIpV4StaticAddrDefGwCisco UCS vnic:IpV4StaticAddr:defGw managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.22.1.5
cucsVnicIpV4StaticAddrSubnetCisco UCS vnic:IpV4StaticAddr:subnet managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.22.1.6
cucsVnicIpV4StaticAddrPrimDnsCisco UCS vnic:IpV4StaticAddr:primDns managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.22.1.7
cucsVnicIpV4StaticAddrSecDnsCisco UCS vnic:IpV4StaticAddr:secDns managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.22.1.8
cucsVnicIpcTableCisco UCS vnic:Ipc managed object table
SEQUENCE OF CucsVnicIpcEntry
.1.3.6.1.4.1.9.9.719.1.53.23
cucsVnicIpcEntryEntry for the cucsVnicIpcTable table.
CucsVnicIpcEntry
.1.3.6.1.4.1.9.9.719.1.53.23.1
cucsVnicIpcInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.1
cucsVnicIpcDnCisco UCS vnic:Ipc:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.2
cucsVnicIpcRnCisco UCS vnic:Ipc:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.3
cucsVnicIpcAdaptorProfileNameCisco UCS vnic:Ipc:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.4
cucsVnicIpcAddrCisco UCS vnic:Ipc:addr managed object propertyro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.23.1.5
cucsVnicIpcAdminVconCisco UCS vnic:Ipc:adminVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.6
cucsVnicIpcBootDevCisco UCS vnic:Ipc:bootDev managed object propertyro
CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.7
cucsVnicIpcConfigStateCisco UCS vnic:Ipc:configState managed object propertyro
CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.8
cucsVnicIpcEquipmentDnCisco UCS vnic:Ipc:equipmentDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.9
cucsVnicIpcIdentPoolNameCisco UCS vnic:Ipc:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.10
cucsVnicIpcInstTypeCisco UCS vnic:Ipc:instType managed object propertyro
CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.11
cucsVnicIpcMtuCisco UCS vnic:Ipc:mtu managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.23.1.12
cucsVnicIpcNameCisco UCS vnic:Ipc:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.13
cucsVnicIpcNwCtrlPolicyNameCisco UCS vnic:Ipc:nwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.14
cucsVnicIpcNwTemplNameCisco UCS vnic:Ipc:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.15
cucsVnicIpcOperAdaptorProfileNameCisco UCS vnic:Ipc:operAdaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.16
cucsVnicIpcOperIdentPoolNameCisco UCS vnic:Ipc:operIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.17
cucsVnicIpcOperNwCtrlPolicyNameCisco UCS vnic:Ipc:operNwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.18
cucsVnicIpcOperNwTemplNameCisco UCS vnic:Ipc:operNwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.19
cucsVnicIpcOperOrderCisco UCS vnic:Ipc:operOrder managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.23.1.20
cucsVnicIpcOperQosPolicyNameCisco UCS vnic:Ipc:operQosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.21
cucsVnicIpcOperSpeedCisco UCS vnic:Ipc:operSpeed managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.23.1.22
cucsVnicIpcOperStatsPolicyNameCisco UCS vnic:Ipc:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.23
cucsVnicIpcOperVconCisco UCS vnic:Ipc:operVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.24
cucsVnicIpcOrderCisco UCS vnic:Ipc:order managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.23.1.25
cucsVnicIpcOwnerCisco UCS vnic:Ipc:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.26
cucsVnicIpcPinToGroupNameCisco UCS vnic:Ipc:pinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.27
cucsVnicIpcQosPolicyNameCisco UCS vnic:Ipc:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.28
cucsVnicIpcStatsPolicyNameCisco UCS vnic:Ipc:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.29
cucsVnicIpcSwitchIdCisco UCS vnic:Ipc:switchId managed object propertyro
CucsVnicEtherBaseSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.30
cucsVnicIpcTypeCisco UCS vnic:Ipc:type managed object propertyro
CucsVnicIpcType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.31
cucsVnicIpcOperPinToGroupNameCisco UCS vnic:Ipc:operPinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.32
cucsVnicIpcConfigQualifierCisco UCS vnic:Ipc:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.33
cucsVnicIpcAdminHostPortCisco UCS vnic:Ipc:adminHostPort managed object propertyro
CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.35
cucsVnicIpcOperHostPortCisco UCS vnic:Ipc:operHostPort managed object propertyro
CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.36
cucsVnicIpcPurposeCisco UCS vnic:Ipc:purpose managed object propertyro
CucsAdaptorPurpose (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.37
cucsVnicIpcAdminCdnNameCisco UCS vnic:Ipc:adminCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.38
cucsVnicIpcOperCdnNameCisco UCS vnic:Ipc:operCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.39
cucsVnicIpcCdnPropInSyncCisco UCS vnic:Ipc:cdnPropInSync managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.23.1.40
cucsVnicIpcCdnSourceCisco UCS vnic:Ipc:cdnSource managed object propertyro
CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.41
cucsVnicIpcRedundancyPairTypeCisco UCS vnic:Ipc:redundancyPairType managed object propertyro
CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.42
cucsVnicIpcRedundancyPeerCisco UCS vnic:Ipc:redundancyPeer managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.23.1.43
cucsVnicIpcIfTableCisco UCS vnic:IpcIf managed object table
SEQUENCE OF CucsVnicIpcIfEntry
.1.3.6.1.4.1.9.9.719.1.53.24
cucsVnicIpcIfEntryEntry for the cucsVnicIpcIfTable table.
CucsVnicIpcIfEntry
.1.3.6.1.4.1.9.9.719.1.53.24.1
cucsVnicIpcIfInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.1
cucsVnicIpcIfDnCisco UCS vnic:IpcIf:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.2
cucsVnicIpcIfRnCisco UCS vnic:IpcIf:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.3
cucsVnicIpcIfAddrCisco UCS vnic:IpcIf:addr managed object propertyro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.24.1.4
cucsVnicIpcIfDefaultNetCisco UCS vnic:IpcIf:defaultNet managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.24.1.5
cucsVnicIpcIfNameCisco UCS vnic:IpcIf:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.6
cucsVnicIpcIfOperStateCisco UCS vnic:IpcIf:operState managed object propertyro
CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.7
cucsVnicIpcIfOwnerCisco UCS vnic:IpcIf:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.8
cucsVnicIpcIfSwitchIdCisco UCS vnic:IpcIf:switchId managed object propertyro
CucsVnicEtherBaseIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.9
cucsVnicIpcIfTypeCisco UCS vnic:IpcIf:type managed object propertyro
CucsVnicAIpcIfType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.10
cucsVnicIpcIfVnetCisco UCS vnic:IpcIf:vnet managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.24.1.11
cucsVnicIpcIfConfigQualifierCisco UCS vnic:IpcIf:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.12
cucsVnicIpcIfOperVnetDnCisco UCS vnic:IpcIf:operVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.14
cucsVnicIpcIfOperVnetNameCisco UCS vnic:IpcIf:operVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.15
cucsVnicIpcIfPubNwIdCisco UCS vnic:IpcIf:pubNwId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.24.1.16
cucsVnicIpcIfSharingCisco UCS vnic:IpcIf:sharing managed object propertyro
CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.17
cucsVnicIpcIfOperPrimaryVnetDnCisco UCS vnic:IpcIf:operPrimaryVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.18
cucsVnicIpcIfOperPrimaryVnetNameCisco UCS vnic:IpcIf:operPrimaryVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.24.1.19
cucsVnicLanConnTemplTableCisco UCS vnic:LanConnTempl managed object table
SEQUENCE OF CucsVnicLanConnTemplEntry
.1.3.6.1.4.1.9.9.719.1.53.25
cucsVnicLanConnTemplEntryEntry for the cucsVnicLanConnTemplTable table.
CucsVnicLanConnTemplEntry
.1.3.6.1.4.1.9.9.719.1.53.25.1
cucsVnicLanConnTemplInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.1
cucsVnicLanConnTemplDnCisco UCS vnic:LanConnTempl:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.2
cucsVnicLanConnTemplRnCisco UCS vnic:LanConnTempl:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.3
cucsVnicLanConnTemplDescrCisco UCS vnic:LanConnTempl:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.4
cucsVnicLanConnTemplIdentPoolNameCisco UCS vnic:LanConnTempl:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.5
cucsVnicLanConnTemplIntIdCisco UCS vnic:LanConnTempl:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.6
cucsVnicLanConnTemplMtuCisco UCS vnic:LanConnTempl:mtu managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.25.1.7
cucsVnicLanConnTemplNameCisco UCS vnic:LanConnTempl:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.8
cucsVnicLanConnTemplNwCtrlPolicyNameCisco UCS vnic:LanConnTempl:nwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.9
cucsVnicLanConnTemplOperIdentPoolNameCisco UCS vnic:LanConnTempl:operIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.10
cucsVnicLanConnTemplOperNwCtrlPolicyNameCisco UCS vnic:LanConnTempl:operNwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.11
cucsVnicLanConnTemplOperQosPolicyNameCisco UCS vnic:LanConnTempl:operQosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.12
cucsVnicLanConnTemplOperStatsPolicyNameCisco UCS vnic:LanConnTempl:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.13
cucsVnicLanConnTemplPinToGroupNameCisco UCS vnic:LanConnTempl:pinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.14
cucsVnicLanConnTemplQosPolicyNameCisco UCS vnic:LanConnTempl:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.15
cucsVnicLanConnTemplStatsPolicyNameCisco UCS vnic:LanConnTempl:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.16
cucsVnicLanConnTemplSwitchIdCisco UCS vnic:LanConnTempl:switchId managed object propertyro
CucsVnicLanConnTemplSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.17
cucsVnicLanConnTemplTargetCisco UCS vnic:LanConnTempl:target managed object propertyro
CucsVnicTemplateTarget (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.18
cucsVnicLanConnTemplTemplTypeCisco UCS vnic:LanConnTempl:templType managed object propertyro
CucsVnicTemplateType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.19
cucsVnicLanConnTemplPolicyLevelCisco UCS vnic:LanConnTempl:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.25.1.20
cucsVnicLanConnTemplPolicyOwnerCisco UCS vnic:LanConnTempl:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.21
cucsVnicLanConnTemplAdminCdnNameCisco UCS vnic:LanConnTempl:adminCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.22
cucsVnicLanConnTemplCdnSourceCisco UCS vnic:LanConnTempl:cdnSource managed object propertyro
CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.23
cucsVnicLanConnTemplOperPeerRedundancyTemplNameCisco UCS vnic:LanConnTempl:operPeerRedundancyTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.24
cucsVnicLanConnTemplPeerRedundancyTemplNameCisco UCS vnic:LanConnTempl:peerRedundancyTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.25
cucsVnicLanConnTemplRedundancyPairTypeCisco UCS vnic:LanConnTempl:redundancyPairType managed object propertyro
CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.25.1.26
cucsVnicLifVlanTableCisco UCS vnic:LifVlan managed object table
SEQUENCE OF CucsVnicLifVlanEntry
.1.3.6.1.4.1.9.9.719.1.53.26
cucsVnicLifVlanEntryEntry for the cucsVnicLifVlanTable table.
CucsVnicLifVlanEntry
.1.3.6.1.4.1.9.9.719.1.53.26.1
cucsVnicLifVlanInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.1
cucsVnicLifVlanDnCisco UCS vnic:LifVlan:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.2
cucsVnicLifVlanRnCisco UCS vnic:LifVlan:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.3
cucsVnicLifVlanAddrCisco UCS vnic:LifVlan:addr managed object propertyro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.26.1.4
cucsVnicLifVlanDefaultNetCisco UCS vnic:LifVlan:defaultNet managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.26.1.5
cucsVnicLifVlanNameCisco UCS vnic:LifVlan:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.6
cucsVnicLifVlanOperStateCisco UCS vnic:LifVlan:operState managed object propertyro
CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.7
cucsVnicLifVlanOwnerCisco UCS vnic:LifVlan:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.8
cucsVnicLifVlanSwitchIdCisco UCS vnic:LifVlan:switchId managed object propertyro
CucsVnicEtherBaseIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.9
cucsVnicLifVlanTypeCisco UCS vnic:LifVlan:type managed object propertyro
CucsVnicAEtherIfType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.10
cucsVnicLifVlanVnetCisco UCS vnic:LifVlan:vnet managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.26.1.11
cucsVnicLifVlanConfigQualifierCisco UCS vnic:LifVlan:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.12
cucsVnicLifVlanOperVnetDnCisco UCS vnic:LifVlan:operVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.14
cucsVnicLifVlanOperVnetNameCisco UCS vnic:LifVlan:operVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.15
cucsVnicLifVlanPubNwIdCisco UCS vnic:LifVlan:pubNwId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.26.1.16
cucsVnicLifVlanSharingCisco UCS vnic:LifVlan:sharing managed object propertyro
CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.17
cucsVnicLifVlanPropAclCisco UCS vnic:LifVlan:propAcl managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.26.1.18
cucsVnicLifVlanOperPrimaryVnetDnCisco UCS vnic:LifVlan:operPrimaryVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.19
cucsVnicLifVlanOperPrimaryVnetNameCisco UCS vnic:LifVlan:operPrimaryVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.26.1.20
cucsVnicLifVsanTableCisco UCS vnic:LifVsan managed object table
SEQUENCE OF CucsVnicLifVsanEntry
.1.3.6.1.4.1.9.9.719.1.53.27
cucsVnicLifVsanEntryEntry for the cucsVnicLifVsanTable table.
CucsVnicLifVsanEntry
.1.3.6.1.4.1.9.9.719.1.53.27.1
cucsVnicLifVsanInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.1
cucsVnicLifVsanDnCisco UCS vnic:LifVsan:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.2
cucsVnicLifVsanRnCisco UCS vnic:LifVsan:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.3
cucsVnicLifVsanInitiatorCisco UCS vnic:LifVsan:initiator managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.27.1.4
cucsVnicLifVsanNameCisco UCS vnic:LifVsan:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.5
cucsVnicLifVsanOperStateCisco UCS vnic:LifVsan:operState managed object propertyro
CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.6
cucsVnicLifVsanOwnerCisco UCS vnic:LifVsan:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.7
cucsVnicLifVsanSwitchIdCisco UCS vnic:LifVsan:switchId managed object propertyro
CucsVnicAFcIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.8
cucsVnicLifVsanTypeCisco UCS vnic:LifVsan:type managed object propertyro
CucsVnicAFcIfType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.9
cucsVnicLifVsanVnetCisco UCS vnic:LifVsan:vnet managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.27.1.10
cucsVnicLifVsanConfigQualifierCisco UCS vnic:LifVsan:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.11
cucsVnicLifVsanOperVnetDnCisco UCS vnic:LifVsan:operVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.13
cucsVnicLifVsanOperVnetNameCisco UCS vnic:LifVsan:operVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.14
cucsVnicLifVsanPubNwIdCisco UCS vnic:LifVsan:pubNwId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.27.1.15
cucsVnicLifVsanSharingCisco UCS vnic:LifVsan:sharing managed object propertyro
CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.16
cucsVnicLifVsanOperPrimaryVnetDnCisco UCS vnic:LifVsan:operPrimaryVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.17
cucsVnicLifVsanOperPrimaryVnetNameCisco UCS vnic:LifVsan:operPrimaryVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.27.1.18
cucsVnicProfileTableCisco UCS vnic:Profile managed object table
SEQUENCE OF CucsVnicProfileEntry
.1.3.6.1.4.1.9.9.719.1.53.28
cucsVnicProfileEntryEntry for the cucsVnicProfileTable table.
CucsVnicProfileEntry
.1.3.6.1.4.1.9.9.719.1.53.28.1
cucsVnicProfileInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.1
cucsVnicProfileDnCisco UCS vnic:Profile:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.2
cucsVnicProfileRnCisco UCS vnic:Profile:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.3
cucsVnicProfileCdpCisco UCS vnic:Profile:cdp managed object propertyro
CucsNwctrlAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.5
cucsVnicProfileCosCisco UCS vnic:Profile:cos managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.28.1.6
cucsVnicProfileDescrCisco UCS vnic:Profile:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.7
cucsVnicProfileForgeMacCisco UCS vnic:Profile:forgeMac managed object propertyro
CucsDpsecForgedTransmit (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.8
cucsVnicProfileIntIdCisco UCS vnic:Profile:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.9
cucsVnicProfileMaxPortsCisco UCS vnic:Profile:maxPorts managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.28.1.10
cucsVnicProfileNameCisco UCS vnic:Profile:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.11
cucsVnicProfileNwCtrlPolicyNameCisco UCS vnic:Profile:nwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.12
cucsVnicProfileOperNwCtrlPolicyNameCisco UCS vnic:Profile:operNwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.13
cucsVnicProfileOperQosPolicyNameCisco UCS vnic:Profile:operQosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.14
cucsVnicProfilePinToGroupNameCisco UCS vnic:Profile:pinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.15
cucsVnicProfileQosPolicyIdCisco UCS vnic:Profile:qosPolicyId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.16
cucsVnicProfileQosPolicyNameCisco UCS vnic:Profile:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.17
cucsVnicProfileSwABorderPortCisco UCS vnic:Profile:swABorderPort managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.28.1.19
cucsVnicProfileSwABorderSlotCisco UCS vnic:Profile:swABorderSlot managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.28.1.20
cucsVnicProfileSwBBorderPortCisco UCS vnic:Profile:swBBorderPort managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.28.1.21
cucsVnicProfileSwBBorderSlotCisco UCS vnic:Profile:swBBorderSlot managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.28.1.22
cucsVnicProfileUplinkFailActionCisco UCS vnic:Profile:uplinkFailAction managed object propertyro
CucsNwctrlLinkFailAction (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.23
cucsVnicProfileHostNwIOPerfCisco UCS vnic:Profile:hostNwIOPerf managed object propertyro
CucsVnicHostNwIOPerfPref (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.24
cucsVnicProfilePrimaryVlanIdCisco UCS vnic:Profile:primaryVlanId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.28.1.25
cucsVnicProfileQosPolicyDnCisco UCS vnic:Profile:qosPolicyDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.26
cucsVnicProfileConfigQualifierCisco UCS vnic:Profile:configQualifier managed object propertyro
CucsVnicProfileConfigQualifier (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.27
cucsVnicProfileMacRegisterModeCisco UCS vnic:Profile:macRegisterMode managed object propertyro
CucsNwctrlRegistrationMode (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.28
cucsVnicProfilePolicyLevelCisco UCS vnic:Profile:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.28.1.29
cucsVnicProfilePolicyOwnerCisco UCS vnic:Profile:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.30
cucsVnicProfilePortProfileUuidCisco UCS vnic:Profile:portProfileUuid managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.31
cucsVnicProfileTypeCisco UCS vnic:Profile:type managed object propertyro
CucsVnicPortProfileType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.32
cucsVnicProfileSwABorderAggrPortCisco UCS vnic:Profile:swABorderAggrPort managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.28.1.33
cucsVnicProfileSwBBorderAggrPortCisco UCS vnic:Profile:swBBorderAggrPort managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.28.1.34
cucsVnicProfileLldpCisco UCS vnic:Profile:lldp managed object propertyro
CucsNwctrlLldpAdminStateBitmask (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.28.1.35
cucsVnicProfileAliasTableCisco UCS vnic:ProfileAlias managed object table
SEQUENCE OF CucsVnicProfileAliasEntry
.1.3.6.1.4.1.9.9.719.1.53.29
cucsVnicProfileAliasEntryEntry for the cucsVnicProfileAliasTable table.
CucsVnicProfileAliasEntry
.1.3.6.1.4.1.9.9.719.1.53.29.1
cucsVnicProfileAliasInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.29.1.1
cucsVnicProfileAliasDnCisco UCS vnic:ProfileAlias:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.29.1.2
cucsVnicProfileAliasRnCisco UCS vnic:ProfileAlias:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.29.1.3
cucsVnicProfileAliasAliasCisco UCS vnic:ProfileAlias:alias managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.29.1.4
cucsVnicProfileAliasSwUuidCisco UCS vnic:ProfileAlias:swUuid managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.29.1.5
cucsVnicProfileSetTableCisco UCS vnic:ProfileSet managed object table
SEQUENCE OF CucsVnicProfileSetEntry
.1.3.6.1.4.1.9.9.719.1.53.30
cucsVnicProfileSetEntryEntry for the cucsVnicProfileSetTable table.
CucsVnicProfileSetEntry
.1.3.6.1.4.1.9.9.719.1.53.30.1
cucsVnicProfileSetInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.30.1.1
cucsVnicProfileSetDnCisco UCS vnic:ProfileSet:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.30.1.2
cucsVnicProfileSetRnCisco UCS vnic:ProfileSet:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.30.1.3
cucsVnicProfileSetFsmDescrCisco UCS vnic:ProfileSet:fsmDescr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.30.1.4
cucsVnicProfileSetFsmPrevCisco UCS vnic:ProfileSet:fsmPrev managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.30.1.5
cucsVnicProfileSetFsmProgrCisco UCS vnic:ProfileSet:fsmProgr managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.30.1.6
cucsVnicProfileSetFsmRmtInvErrCodeCisco UCS vnic:ProfileSet:fsmRmtInvErrCode managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.30.1.7
cucsVnicProfileSetFsmRmtInvErrDescrCisco UCS vnic:ProfileSet:fsmRmtInvErrDescr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.30.1.8
cucsVnicProfileSetFsmRmtInvRsltCisco UCS vnic:ProfileSet:fsmRmtInvRslt managed object propertyro
CucsConditionRemoteInvRslt (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.30.1.9
cucsVnicProfileSetFsmStageDescrCisco UCS vnic:ProfileSet:fsmStageDescr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.30.1.10
cucsVnicProfileSetFsmStampCisco UCS vnic:ProfileSet:fsmStamp managed object propertyro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.30.1.11
cucsVnicProfileSetFsmStatusCisco UCS vnic:ProfileSet:fsmStatus managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.30.1.12
cucsVnicProfileSetFsmTryCisco UCS vnic:ProfileSet:fsmTry managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.30.1.13
cucsVnicProfileSetFltAggrCisco UCS vnic:ProfileSet:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.30.1.14
cucsVnicProfileSetGenNumCisco UCS vnic:ProfileSet:genNum managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.30.1.15
cucsVnicProfileSetVlanGroupUpdateCisco UCS vnic:ProfileSet:vlanGroupUpdate managed object propertyro
CucsVnicVlanGroupUpdate (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.30.1.16
cucsVnicProfileSetFsmTaskTableCisco UCS vnic:ProfileSetFsmTask managed object table
SEQUENCE OF CucsVnicProfileSetFsmTaskEntry
.1.3.6.1.4.1.9.9.719.1.53.31
cucsVnicProfileSetFsmTaskEntryEntry for the cucsVnicProfileSetFsmTaskTable table.
CucsVnicProfileSetFsmTaskEntry
.1.3.6.1.4.1.9.9.719.1.53.31.1
cucsVnicProfileSetFsmTaskInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.31.1.1
cucsVnicProfileSetFsmTaskDnCisco UCS vnic:ProfileSetFsmTask:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.31.1.2
cucsVnicProfileSetFsmTaskRnCisco UCS vnic:ProfileSetFsmTask:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.31.1.3
cucsVnicProfileSetFsmTaskCompletionCisco UCS vnic:ProfileSetFsmTask:completion managed object propertyro
CucsFsmCompletion (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.31.1.4
cucsVnicProfileSetFsmTaskFlagsCisco UCS vnic:ProfileSetFsmTask:flags managed object propertyro
CucsFsmFlags (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.31.1.5
cucsVnicProfileSetFsmTaskItemCisco UCS vnic:ProfileSetFsmTask:item managed object propertyro
CucsVnicProfileSetFsmTaskItem (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.31.1.6
cucsVnicProfileSetFsmTaskSeqIdCisco UCS vnic:ProfileSetFsmTask:seqId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.31.1.7
cucsVnicSanConnTemplTableCisco UCS vnic:SanConnTempl managed object table
SEQUENCE OF CucsVnicSanConnTemplEntry
.1.3.6.1.4.1.9.9.719.1.53.32
cucsVnicSanConnTemplEntryEntry for the cucsVnicSanConnTemplTable table.
CucsVnicSanConnTemplEntry
.1.3.6.1.4.1.9.9.719.1.53.32.1
cucsVnicSanConnTemplInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.1
cucsVnicSanConnTemplDnCisco UCS vnic:SanConnTempl:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.2
cucsVnicSanConnTemplRnCisco UCS vnic:SanConnTempl:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.3
cucsVnicSanConnTemplDescrCisco UCS vnic:SanConnTempl:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.4
cucsVnicSanConnTemplIdentPoolNameCisco UCS vnic:SanConnTempl:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.5
cucsVnicSanConnTemplIntIdCisco UCS vnic:SanConnTempl:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.6
cucsVnicSanConnTemplMaxDataFieldSizeCisco UCS vnic:SanConnTempl:maxDataFieldSize managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.32.1.7
cucsVnicSanConnTemplNameCisco UCS vnic:SanConnTempl:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.8
cucsVnicSanConnTemplNwCtrlPolicyNameCisco UCS vnic:SanConnTempl:nwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.9
cucsVnicSanConnTemplOperIdentPoolNameCisco UCS vnic:SanConnTempl:operIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.10
cucsVnicSanConnTemplOperQosPolicyNameCisco UCS vnic:SanConnTempl:operQosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.11
cucsVnicSanConnTemplOperStatsPolicyNameCisco UCS vnic:SanConnTempl:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.12
cucsVnicSanConnTemplPinToGroupNameCisco UCS vnic:SanConnTempl:pinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.13
cucsVnicSanConnTemplQosPolicyNameCisco UCS vnic:SanConnTempl:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.14
cucsVnicSanConnTemplStatsPolicyNameCisco UCS vnic:SanConnTempl:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.15
cucsVnicSanConnTemplSwitchIdCisco UCS vnic:SanConnTempl:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.16
cucsVnicSanConnTemplTargetCisco UCS vnic:SanConnTempl:target managed object propertyro
CucsVnicSanConnTemplTarget (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.17
cucsVnicSanConnTemplTemplTypeCisco UCS vnic:SanConnTempl:templType managed object propertyro
CucsVnicTemplateType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.18
cucsVnicSanConnTemplPolicyLevelCisco UCS vnic:SanConnTempl:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.32.1.19
cucsVnicSanConnTemplPolicyOwnerCisco UCS vnic:SanConnTempl:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.20
cucsVnicSanConnTemplOperPeerRedundancyTemplNameCisco UCS vnic:SanConnTempl:operPeerRedundancyTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.21
cucsVnicSanConnTemplPeerRedundancyTemplNameCisco UCS vnic:SanConnTempl:peerRedundancyTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.22
cucsVnicSanConnTemplRedundancyPairTypeCisco UCS vnic:SanConnTempl:redundancyPairType managed object propertyro
CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.32.1.23
cucsVnicScsiTableCisco UCS vnic:Scsi managed object table
SEQUENCE OF CucsVnicScsiEntry
.1.3.6.1.4.1.9.9.719.1.53.33
cucsVnicScsiEntryEntry for the cucsVnicScsiTable table.
CucsVnicScsiEntry
.1.3.6.1.4.1.9.9.719.1.53.33.1
cucsVnicScsiInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.1
cucsVnicScsiDnCisco UCS vnic:Scsi:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.2
cucsVnicScsiRnCisco UCS vnic:Scsi:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.3
cucsVnicScsiAdaptorProfileNameCisco UCS vnic:Scsi:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.4
cucsVnicScsiAdminVconCisco UCS vnic:Scsi:adminVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.5
cucsVnicScsiBootDevCisco UCS vnic:Scsi:bootDev managed object propertyro
CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.6
cucsVnicScsiConfigStateCisco UCS vnic:Scsi:configState managed object propertyro
CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.7
cucsVnicScsiEquipmentDnCisco UCS vnic:Scsi:equipmentDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.8
cucsVnicScsiIdentPoolNameCisco UCS vnic:Scsi:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.9
cucsVnicScsiInstTypeCisco UCS vnic:Scsi:instType managed object propertyro
CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.10
cucsVnicScsiNameCisco UCS vnic:Scsi:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.11
cucsVnicScsiNwTemplNameCisco UCS vnic:Scsi:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.12
cucsVnicScsiOperOrderCisco UCS vnic:Scsi:operOrder managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.33.1.13
cucsVnicScsiOperSpeedCisco UCS vnic:Scsi:operSpeed managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.33.1.14
cucsVnicScsiOperStatsPolicyNameCisco UCS vnic:Scsi:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.15
cucsVnicScsiOperVconCisco UCS vnic:Scsi:operVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.16
cucsVnicScsiOrderCisco UCS vnic:Scsi:order managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.33.1.17
cucsVnicScsiOwnerCisco UCS vnic:Scsi:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.18
cucsVnicScsiPinToGroupNameCisco UCS vnic:Scsi:pinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.19
cucsVnicScsiQosPolicyNameCisco UCS vnic:Scsi:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.20
cucsVnicScsiStatsPolicyNameCisco UCS vnic:Scsi:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.21
cucsVnicScsiSwitchIdCisco UCS vnic:Scsi:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.22
cucsVnicScsiTypeCisco UCS vnic:Scsi:type managed object propertyro
CucsVnicScsiType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.23
cucsVnicScsiConfigQualifierCisco UCS vnic:Scsi:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.25
cucsVnicScsiAdminHostPortCisco UCS vnic:Scsi:adminHostPort managed object propertyro
CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.27
cucsVnicScsiOperHostPortCisco UCS vnic:Scsi:operHostPort managed object propertyro
CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.28
cucsVnicScsiAdminCdnNameCisco UCS vnic:Scsi:adminCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.29
cucsVnicScsiOperCdnNameCisco UCS vnic:Scsi:operCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.30
cucsVnicScsiCdnPropInSyncCisco UCS vnic:Scsi:cdnPropInSync managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.33.1.31
cucsVnicScsiCdnSourceCisco UCS vnic:Scsi:cdnSource managed object propertyro
CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.32
cucsVnicScsiRedundancyPairTypeCisco UCS vnic:Scsi:redundancyPairType managed object propertyro
CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.33
cucsVnicScsiRedundancyPeerCisco UCS vnic:Scsi:redundancyPeer managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.33.1.34
cucsVnicScsiIfTableCisco UCS vnic:ScsiIf managed object table
SEQUENCE OF CucsVnicScsiIfEntry
.1.3.6.1.4.1.9.9.719.1.53.34
cucsVnicScsiIfEntryEntry for the cucsVnicScsiIfTable table.
CucsVnicScsiIfEntry
.1.3.6.1.4.1.9.9.719.1.53.34.1
cucsVnicScsiIfInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.1
cucsVnicScsiIfDnCisco UCS vnic:ScsiIf:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.2
cucsVnicScsiIfRnCisco UCS vnic:ScsiIf:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.3
cucsVnicScsiIfAddrCisco UCS vnic:ScsiIf:addr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.34.1.4
cucsVnicScsiIfNameCisco UCS vnic:ScsiIf:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.5
cucsVnicScsiIfOperStateCisco UCS vnic:ScsiIf:operState managed object propertyro
CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.6
cucsVnicScsiIfOwnerCisco UCS vnic:ScsiIf:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.7
cucsVnicScsiIfSwitchIdCisco UCS vnic:ScsiIf:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.8
cucsVnicScsiIfTypeCisco UCS vnic:ScsiIf:type managed object propertyro
CucsVnicAScsiIfType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.9
cucsVnicScsiIfVnetCisco UCS vnic:ScsiIf:vnet managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.34.1.10
cucsVnicScsiIfConfigQualifierCisco UCS vnic:ScsiIf:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.11
cucsVnicScsiIfOperVnetDnCisco UCS vnic:ScsiIf:operVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.13
cucsVnicScsiIfOperVnetNameCisco UCS vnic:ScsiIf:operVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.14
cucsVnicScsiIfPubNwIdCisco UCS vnic:ScsiIf:pubNwId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.34.1.15
cucsVnicScsiIfSharingCisco UCS vnic:ScsiIf:sharing managed object propertyro
CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.16
cucsVnicScsiIfOperPrimaryVnetDnCisco UCS vnic:ScsiIf:operPrimaryVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.17
cucsVnicScsiIfOperPrimaryVnetNameCisco UCS vnic:ScsiIf:operPrimaryVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.34.1.18
cucsVnicBootIpPolicyTableCisco UCS vnic:BootIpPolicy managed object table
SEQUENCE OF CucsVnicBootIpPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.35
cucsVnicBootIpPolicyEntryEntry for the cucsVnicBootIpPolicyTable table.
CucsVnicBootIpPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.35.1
cucsVnicBootIpPolicyInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.35.1.1
cucsVnicBootIpPolicyDnCisco UCS vnic:BootIpPolicy:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.35.1.2
cucsVnicBootIpPolicyRnCisco UCS vnic:BootIpPolicy:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.35.1.3
cucsVnicBootIpPolicyDescrCisco UCS vnic:BootIpPolicy:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.35.1.4
cucsVnicBootIpPolicyIntIdCisco UCS vnic:BootIpPolicy:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.35.1.5
cucsVnicBootIpPolicyNameCisco UCS vnic:BootIpPolicy:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.35.1.6
cucsVnicBootIpPolicyPoolNameCisco UCS vnic:BootIpPolicy:poolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.35.1.7
cucsVnicBootIpPolicyPolicyLevelCisco UCS vnic:BootIpPolicy:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.35.1.8
cucsVnicBootIpPolicyPolicyOwnerCisco UCS vnic:BootIpPolicy:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.35.1.9
cucsVnicIPv4IscsiAddrTableCisco UCS vnic:IPv4IscsiAddr managed object table
SEQUENCE OF CucsVnicIPv4IscsiAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.36
cucsVnicIPv4IscsiAddrEntryEntry for the cucsVnicIPv4IscsiAddrTable table.
CucsVnicIPv4IscsiAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.36.1
cucsVnicIPv4IscsiAddrInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.36.1.1
cucsVnicIPv4IscsiAddrDnCisco UCS vnic:IPv4IscsiAddr:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.36.1.2
cucsVnicIPv4IscsiAddrRnCisco UCS vnic:IPv4IscsiAddr:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.36.1.3
cucsVnicIPv4IscsiAddrAddrCisco UCS vnic:IPv4IscsiAddr:addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.36.1.4
cucsVnicIPv4IscsiAddrDefGwCisco UCS vnic:IPv4IscsiAddr:defGw managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.36.1.5
cucsVnicIPv4IscsiAddrPrimDnsCisco UCS vnic:IPv4IscsiAddr:primDns managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.36.1.6
cucsVnicIPv4IscsiAddrSecDnsCisco UCS vnic:IPv4IscsiAddr:secDns managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.36.1.7
cucsVnicIPv4IscsiAddrSubnetCisco UCS vnic:IPv4IscsiAddr:subnet managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.36.1.8
cucsVnicIPv4PooledIscsiAddrTableCisco UCS vnic:IPv4PooledIscsiAddr managed object table
SEQUENCE OF CucsVnicIPv4PooledIscsiAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.37
cucsVnicIPv4PooledIscsiAddrEntryEntry for the cucsVnicIPv4PooledIscsiAddrTable table.
CucsVnicIPv4PooledIscsiAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.37.1
cucsVnicIPv4PooledIscsiAddrInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.37.1.1
cucsVnicIPv4PooledIscsiAddrDnCisco UCS vnic:IPv4PooledIscsiAddr:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.37.1.2
cucsVnicIPv4PooledIscsiAddrRnCisco UCS vnic:IPv4PooledIscsiAddr:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.37.1.3
cucsVnicIPv4PooledIscsiAddrAddrCisco UCS vnic:IPv4PooledIscsiAddr:addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.37.1.4
cucsVnicIPv4PooledIscsiAddrDefGwCisco UCS vnic:IPv4PooledIscsiAddr:defGw managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.37.1.5
cucsVnicIPv4PooledIscsiAddrIdentPoolNameCisco UCS vnic:IPv4PooledIscsiAddr:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.37.1.6
cucsVnicIPv4PooledIscsiAddrOperIdentPoolNameCisco UCS vnic:IPv4PooledIscsiAddr:operIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.37.1.7
cucsVnicIPv4PooledIscsiAddrPrimDnsCisco UCS vnic:IPv4PooledIscsiAddr:primDns managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.37.1.8
cucsVnicIPv4PooledIscsiAddrSecDnsCisco UCS vnic:IPv4PooledIscsiAddr:secDns managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.37.1.9
cucsVnicIPv4PooledIscsiAddrSubnetCisco UCS vnic:IPv4PooledIscsiAddr:subnet managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.37.1.10
cucsVnicIScsiTableCisco UCS vnic:IScsi managed object table
SEQUENCE OF CucsVnicIScsiEntry
.1.3.6.1.4.1.9.9.719.1.53.38
cucsVnicIScsiEntryEntry for the cucsVnicIScsiTable table.
CucsVnicIScsiEntry
.1.3.6.1.4.1.9.9.719.1.53.38.1
cucsVnicIScsiInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.1
cucsVnicIScsiDnCisco UCS vnic:IScsi:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.2
cucsVnicIScsiRnCisco UCS vnic:IScsi:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.3
cucsVnicIScsiAdaptorProfileNameCisco UCS vnic:IScsi:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.4
cucsVnicIScsiAddrCisco UCS vnic:IScsi:addr managed object propertyro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.38.1.5
cucsVnicIScsiAdminVconCisco UCS vnic:IScsi:adminVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.6
cucsVnicIScsiAuthProfileNameCisco UCS vnic:IScsi:authProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.7
cucsVnicIScsiBootDevCisco UCS vnic:IScsi:bootDev managed object propertyro
CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.8
cucsVnicIScsiConfigStateCisco UCS vnic:IScsi:configState managed object propertyro
CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.10
cucsVnicIScsiEquipmentDnCisco UCS vnic:IScsi:equipmentDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.11
cucsVnicIScsiEthEpDnCisco UCS vnic:IScsi:ethEpDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.12
cucsVnicIScsiExtIPStateCisco UCS vnic:IScsi:extIPState managed object propertyro
CucsVnicExternalMgmtIPMode (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.13
cucsVnicIScsiFltAggrCisco UCS vnic:IScsi:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.38.1.14
cucsVnicIScsiIdentPoolNameCisco UCS vnic:IScsi:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.15
cucsVnicIScsiInitiatorNameCisco UCS vnic:IScsi:initiatorName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.16
cucsVnicIScsiInstTypeCisco UCS vnic:IScsi:instType managed object propertyro
CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.17
cucsVnicIScsiIqnIdentPoolNameCisco UCS vnic:IScsi:iqnIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.18
cucsVnicIScsiNameCisco UCS vnic:IScsi:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.19
cucsVnicIScsiNwTemplNameCisco UCS vnic:IScsi:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.20
cucsVnicIScsiOperAdaptorProfileNameCisco UCS vnic:IScsi:operAdaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.21
cucsVnicIScsiOperAuthProfileNameCisco UCS vnic:IScsi:operAuthProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.22
cucsVnicIScsiOperIqnIdentPoolNameCisco UCS vnic:IScsi:operIqnIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.24
cucsVnicIScsiOperOrderCisco UCS vnic:IScsi:operOrder managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.38.1.25
cucsVnicIScsiOperSpeedCisco UCS vnic:IScsi:operSpeed managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.38.1.27
cucsVnicIScsiOperStatsPolicyNameCisco UCS vnic:IScsi:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.28
cucsVnicIScsiOperVconCisco UCS vnic:IScsi:operVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.29
cucsVnicIScsiOrderCisco UCS vnic:IScsi:order managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.38.1.30
cucsVnicIScsiOwnerCisco UCS vnic:IScsi:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.31
cucsVnicIScsiPinToGroupNameCisco UCS vnic:IScsi:pinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.32
cucsVnicIScsiQosPolicyNameCisco UCS vnic:IScsi:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.33
cucsVnicIScsiStatsPolicyNameCisco UCS vnic:IScsi:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.34
cucsVnicIScsiSwitchIdCisco UCS vnic:IScsi:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.35
cucsVnicIScsiTypeCisco UCS vnic:IScsi:type managed object propertyro
CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.36
cucsVnicIScsiVnicDefTypeCisco UCS vnic:IScsi:vnicDefType managed object propertyro
CucsVnicIScsiIfDefType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.37
cucsVnicIScsiVnicNameCisco UCS vnic:IScsi:vnicName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.38
cucsVnicIScsiConfigQualifierCisco UCS vnic:IScsi:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.39
cucsVnicIScsiInitNameSuffixCisco UCS vnic:IScsi:initNameSuffix managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.40
cucsVnicIScsiOperIdentPoolNameCisco UCS vnic:IScsi:operIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.41
cucsVnicIScsiAdminHostPortCisco UCS vnic:IScsi:adminHostPort managed object propertyro
CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.43
cucsVnicIScsiOperHostPortCisco UCS vnic:IScsi:operHostPort managed object propertyro
CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.44
cucsVnicIScsiPropAclCisco UCS vnic:IScsi:propAcl managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.38.1.45
cucsVnicIScsiAdminCdnNameCisco UCS vnic:IScsi:adminCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.47
cucsVnicIScsiOperCdnNameCisco UCS vnic:IScsi:operCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.48
cucsVnicIScsiCdnSourceCisco UCS vnic:IScsi:cdnSource managed object propertyro
CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.49
cucsVnicIScsiCdnPropInSyncCisco UCS vnic:IScsi:cdnPropInSync managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.38.1.50
cucsVnicIScsiRedundancyPairTypeCisco UCS vnic:IScsi:redundancyPairType managed object propertyro
CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.51
cucsVnicIScsiRedundancyPeerCisco UCS vnic:IScsi:redundancyPeer managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.38.1.52
cucsVnicIScsiAutoTargetIfTableCisco UCS vnic:IScsiAutoTargetIf managed object table
SEQUENCE OF CucsVnicIScsiAutoTargetIfEntry
.1.3.6.1.4.1.9.9.719.1.53.39
cucsVnicIScsiAutoTargetIfEntryEntry for the cucsVnicIScsiAutoTargetIfTable table.
CucsVnicIScsiAutoTargetIfEntry
.1.3.6.1.4.1.9.9.719.1.53.39.1
cucsVnicIScsiAutoTargetIfInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.39.1.1
cucsVnicIScsiAutoTargetIfDnCisco UCS vnic:IScsiAutoTargetIf:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.39.1.2
cucsVnicIScsiAutoTargetIfRnCisco UCS vnic:IScsiAutoTargetIf:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.39.1.3
cucsVnicIScsiAutoTargetIfDhcpVendorIdCisco UCS vnic:IScsiAutoTargetIf:dhcpVendorId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.39.1.4
cucsVnicIScsiNodeTableCisco UCS vnic:IScsiNode managed object table
SEQUENCE OF CucsVnicIScsiNodeEntry
.1.3.6.1.4.1.9.9.719.1.53.40
cucsVnicIScsiNodeEntryEntry for the cucsVnicIScsiNodeTable table.
CucsVnicIScsiNodeEntry
.1.3.6.1.4.1.9.9.719.1.53.40.1
cucsVnicIScsiNodeInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.40.1.1
cucsVnicIScsiNodeDnCisco UCS vnic:IScsiNode:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.40.1.2
cucsVnicIScsiNodeRnCisco UCS vnic:IScsiNode:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.40.1.3
cucsVnicIScsiNodeFltAggrCisco UCS vnic:IScsiNode:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.40.1.4
cucsVnicIScsiNodeInitiatorNameCisco UCS vnic:IScsiNode:initiatorName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.40.1.5
cucsVnicIScsiNodeOwnerCisco UCS vnic:IScsiNode:owner managed object propertyro
CucsVnicIScsiNodeOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.40.1.6
cucsVnicIScsiNodeInitNameSuffixCisco UCS vnic:IScsiNode:initNameSuffix managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.40.1.7
cucsVnicIScsiNodeIqnIdentPoolNameCisco UCS vnic:IScsiNode:iqnIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.40.1.8
cucsVnicIScsiNodeOperIqnIdentPoolNameCisco UCS vnic:IScsiNode:operIqnIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.40.1.9
cucsVnicIScsiNodeInitiatorPolicyNameCisco UCS vnic:IScsiNode:initiatorPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.40.1.10
cucsVnicIScsiNodeOperInitiatorPolicyNameCisco UCS vnic:IScsiNode:operInitiatorPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.40.1.11
cucsVnicIScsiNodePropAclCisco UCS vnic:IScsiNode:propAcl managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.40.1.12
cucsVnicIScsiStaticTargetIfTableCisco UCS vnic:IScsiStaticTargetIf managed object table
SEQUENCE OF CucsVnicIScsiStaticTargetIfEntry
.1.3.6.1.4.1.9.9.719.1.53.41
cucsVnicIScsiStaticTargetIfEntryEntry for the cucsVnicIScsiStaticTargetIfTable table.
CucsVnicIScsiStaticTargetIfEntry
.1.3.6.1.4.1.9.9.719.1.53.41.1
cucsVnicIScsiStaticTargetIfInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.41.1.1
cucsVnicIScsiStaticTargetIfDnCisco UCS vnic:IScsiStaticTargetIf:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.41.1.2
cucsVnicIScsiStaticTargetIfRnCisco UCS vnic:IScsiStaticTargetIf:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.41.1.3
cucsVnicIScsiStaticTargetIfAuthProfileNameCisco UCS vnic:IScsiStaticTargetIf:authProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.41.1.4
cucsVnicIScsiStaticTargetIfIpAddressCisco UCS vnic:IScsiStaticTargetIf:ipAddress managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.41.1.5
cucsVnicIScsiStaticTargetIfNameCisco UCS vnic:IScsiStaticTargetIf:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.41.1.6
cucsVnicIScsiStaticTargetIfOperAuthProfileNameCisco UCS vnic:IScsiStaticTargetIf:operAuthProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.41.1.7
cucsVnicIScsiStaticTargetIfPortCisco UCS vnic:IScsiStaticTargetIf:port managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.41.1.8
cucsVnicIScsiStaticTargetIfPriorityCisco UCS vnic:IScsiStaticTargetIf:priority managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.41.1.9
cucsVnicIScsiStaticTargetIfPropAclCisco UCS vnic:IScsiStaticTargetIf:propAcl managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.41.1.11
cucsVnicInternalProfileTableCisco UCS vnic:InternalProfile managed object table
SEQUENCE OF CucsVnicInternalProfileEntry
.1.3.6.1.4.1.9.9.719.1.53.42
cucsVnicInternalProfileEntryEntry for the cucsVnicInternalProfileTable table.
CucsVnicInternalProfileEntry
.1.3.6.1.4.1.9.9.719.1.53.42.1
cucsVnicInternalProfileInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.42.1.1
cucsVnicInternalProfileDnCisco UCS vnic:InternalProfile:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.42.1.2
cucsVnicInternalProfileRnCisco UCS vnic:InternalProfile:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.42.1.3
cucsVnicInternalProfileDescrCisco UCS vnic:InternalProfile:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.42.1.4
cucsVnicInternalProfileIntIdCisco UCS vnic:InternalProfile:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.42.1.5
cucsVnicInternalProfileMaxPortsCisco UCS vnic:InternalProfile:maxPorts managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.42.1.6
cucsVnicInternalProfileNameCisco UCS vnic:InternalProfile:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.42.1.7
cucsVnicInternalProfilePolicyLevelCisco UCS vnic:InternalProfile:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.42.1.8
cucsVnicInternalProfilePolicyOwnerCisco UCS vnic:InternalProfile:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.42.1.9
cucsVnicLunTableCisco UCS vnic:Lun managed object table
SEQUENCE OF CucsVnicLunEntry
.1.3.6.1.4.1.9.9.719.1.53.43
cucsVnicLunEntryEntry for the cucsVnicLunTable table.
CucsVnicLunEntry
.1.3.6.1.4.1.9.9.719.1.53.43.1
cucsVnicLunInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.43.1.1
cucsVnicLunDnCisco UCS vnic:Lun:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.43.1.2
cucsVnicLunRnCisco UCS vnic:Lun:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.43.1.3
cucsVnicLunBootableCisco UCS vnic:Lun:bootable managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.43.1.4
cucsVnicLunIdCisco UCS vnic:Lun:id managed object propertyro
CucsVnicLunId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.43.1.5
cucsVnicOProfileAliasTableCisco UCS vnic:OProfileAlias managed object table
SEQUENCE OF CucsVnicOProfileAliasEntry
.1.3.6.1.4.1.9.9.719.1.53.44
cucsVnicOProfileAliasEntryEntry for the cucsVnicOProfileAliasTable table.
CucsVnicOProfileAliasEntry
.1.3.6.1.4.1.9.9.719.1.53.44.1
cucsVnicOProfileAliasInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.44.1.1
cucsVnicOProfileAliasDnCisco UCS vnic:OProfileAlias:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.44.1.2
cucsVnicOProfileAliasRnCisco UCS vnic:OProfileAlias:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.44.1.3
cucsVnicOProfileAliasAliasCisco UCS vnic:OProfileAlias:alias managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.44.1.4
cucsVnicOProfileAliasMgmtPlaneCisco UCS vnic:OProfileAlias:mgmtPlane managed object propertyro
CucsVmMgmtPlane (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.44.1.5
cucsVnicOProfileAliasVSwitchIdCisco UCS vnic:OProfileAlias:vSwitchId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.44.1.6
cucsVnicOProfileAliasVSwitchNameCisco UCS vnic:OProfileAlias:vSwitchName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.44.1.7
cucsVnicVlanTableCisco UCS vnic:Vlan managed object table
SEQUENCE OF CucsVnicVlanEntry
.1.3.6.1.4.1.9.9.719.1.53.45
cucsVnicVlanEntryEntry for the cucsVnicVlanTable table.
CucsVnicVlanEntry
.1.3.6.1.4.1.9.9.719.1.53.45.1
cucsVnicVlanInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.1
cucsVnicVlanDnCisco UCS vnic:Vlan:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.2
cucsVnicVlanRnCisco UCS vnic:Vlan:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.3
cucsVnicVlanFltAggrCisco UCS vnic:Vlan:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.45.1.4
cucsVnicVlanNameCisco UCS vnic:Vlan:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.5
cucsVnicVlanOperStateCisco UCS vnic:Vlan:operState managed object propertyro
CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.6
cucsVnicVlanOwnerCisco UCS vnic:Vlan:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.7
cucsVnicVlanSwitchIdCisco UCS vnic:Vlan:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.8
cucsVnicVlanTypeCisco UCS vnic:Vlan:type managed object propertyro
CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.9
cucsVnicVlanVlanNameCisco UCS vnic:Vlan:vlanName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.10
cucsVnicVlanVnetCisco UCS vnic:Vlan:vnet managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.45.1.11
cucsVnicVlanConfigQualifierCisco UCS vnic:Vlan:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.12
cucsVnicVlanOperVnetDnCisco UCS vnic:Vlan:operVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.14
cucsVnicVlanOperVnetNameCisco UCS vnic:Vlan:operVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.15
cucsVnicVlanPubNwIdCisco UCS vnic:Vlan:pubNwId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.45.1.16
cucsVnicVlanSharingCisco UCS vnic:Vlan:sharing managed object propertyro
CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.17
cucsVnicVlanOperPrimaryVnetDnCisco UCS vnic:Vlan:operPrimaryVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.18
cucsVnicVlanOperPrimaryVnetNameCisco UCS vnic:Vlan:operPrimaryVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.45.1.19
cucsVnicConnDefTableCisco UCS vnic:ConnDef managed object table
SEQUENCE OF CucsVnicConnDefEntry
.1.3.6.1.4.1.9.9.719.1.53.46
cucsVnicConnDefEntryEntry for the cucsVnicConnDefTable table.
CucsVnicConnDefEntry
.1.3.6.1.4.1.9.9.719.1.53.46.1
cucsVnicConnDefInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.46.1.1
cucsVnicConnDefDnCisco UCS vnic:ConnDef:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.46.1.2
cucsVnicConnDefRnCisco UCS vnic:ConnDef:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.46.1.3
cucsVnicConnDefFltAggrCisco UCS vnic:ConnDef:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.46.1.4
cucsVnicConnDefLanConnPolicyNameCisco UCS vnic:ConnDef:lanConnPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.46.1.5
cucsVnicConnDefOperLanConnPolicyNameCisco UCS vnic:ConnDef:operLanConnPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.46.1.6
cucsVnicConnDefOperSanConnPolicyNameCisco UCS vnic:ConnDef:operSanConnPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.46.1.7
cucsVnicConnDefSanConnPolicyNameCisco UCS vnic:ConnDef:sanConnPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.46.1.8
cucsVnicConnDefPropAclCisco UCS vnic:ConnDef:propAcl managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.46.1.9
cucsVnicDynamicConPolicyRefTableCisco UCS vnic:DynamicConPolicyRef managed object table
SEQUENCE OF CucsVnicDynamicConPolicyRefEntry
.1.3.6.1.4.1.9.9.719.1.53.47
cucsVnicDynamicConPolicyRefEntryEntry for the cucsVnicDynamicConPolicyRefTable table.
CucsVnicDynamicConPolicyRefEntry
.1.3.6.1.4.1.9.9.719.1.53.47.1
cucsVnicDynamicConPolicyRefInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.47.1.1
cucsVnicDynamicConPolicyRefDnCisco UCS vnic:DynamicConPolicyRef:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.47.1.2
cucsVnicDynamicConPolicyRefRnCisco UCS vnic:DynamicConPolicyRef:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.47.1.3
cucsVnicDynamicConPolicyRefConPolicyNameCisco UCS vnic:DynamicConPolicyRef:conPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.47.1.4
cucsVnicDynamicConPolicyRefOperConPolicyNameCisco UCS vnic:DynamicConPolicyRef:operConPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.47.1.5
cucsVnicFcGroupDefTableCisco UCS vnic:FcGroupDef managed object table
SEQUENCE OF CucsVnicFcGroupDefEntry
.1.3.6.1.4.1.9.9.719.1.53.48
cucsVnicFcGroupDefEntryEntry for the cucsVnicFcGroupDefTable table.
CucsVnicFcGroupDefEntry
.1.3.6.1.4.1.9.9.719.1.53.48.1
cucsVnicFcGroupDefInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.1
cucsVnicFcGroupDefDnCisco UCS vnic:FcGroupDef:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.2
cucsVnicFcGroupDefRnCisco UCS vnic:FcGroupDef:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.3
cucsVnicFcGroupDefAdaptorProfileNameCisco UCS vnic:FcGroupDef:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.4
cucsVnicFcGroupDefDescrCisco UCS vnic:FcGroupDef:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.5
cucsVnicFcGroupDefIdentPoolNameCisco UCS vnic:FcGroupDef:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.6
cucsVnicFcGroupDefIntIdCisco UCS vnic:FcGroupDef:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.7
cucsVnicFcGroupDefMaxDataFieldSizeCisco UCS vnic:FcGroupDef:maxDataFieldSize managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.48.1.8
cucsVnicFcGroupDefNameCisco UCS vnic:FcGroupDef:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.9
cucsVnicFcGroupDefNwTemplNameCisco UCS vnic:FcGroupDef:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.10
cucsVnicFcGroupDefOperStatsPolicyNameCisco UCS vnic:FcGroupDef:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.11
cucsVnicFcGroupDefOperStorageConnPolicyNameCisco UCS vnic:FcGroupDef:operStorageConnPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.12
cucsVnicFcGroupDefPolicyLevelCisco UCS vnic:FcGroupDef:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.48.1.13
cucsVnicFcGroupDefPolicyOwnerCisco UCS vnic:FcGroupDef:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.14
cucsVnicFcGroupDefQosPolicyNameCisco UCS vnic:FcGroupDef:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.15
cucsVnicFcGroupDefStatsPolicyNameCisco UCS vnic:FcGroupDef:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.16
cucsVnicFcGroupDefStorageConnPolicyNameCisco UCS vnic:FcGroupDef:storageConnPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.48.1.17
cucsVnicFcGroupTemplTableCisco UCS vnic:FcGroupTempl managed object table
SEQUENCE OF CucsVnicFcGroupTemplEntry
.1.3.6.1.4.1.9.9.719.1.53.49
cucsVnicFcGroupTemplEntryEntry for the cucsVnicFcGroupTemplTable table.
CucsVnicFcGroupTemplEntry
.1.3.6.1.4.1.9.9.719.1.53.49.1
cucsVnicFcGroupTemplInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.1
cucsVnicFcGroupTemplDnCisco UCS vnic:FcGroupTempl:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.2
cucsVnicFcGroupTemplRnCisco UCS vnic:FcGroupTempl:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.3
cucsVnicFcGroupTemplAdaptorProfileNameCisco UCS vnic:FcGroupTempl:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.4
cucsVnicFcGroupTemplDescrCisco UCS vnic:FcGroupTempl:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.5
cucsVnicFcGroupTemplIdentPoolNameCisco UCS vnic:FcGroupTempl:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.6
cucsVnicFcGroupTemplIntIdCisco UCS vnic:FcGroupTempl:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.7
cucsVnicFcGroupTemplMaxDataFieldSizeCisco UCS vnic:FcGroupTempl:maxDataFieldSize managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.49.1.8
cucsVnicFcGroupTemplNameCisco UCS vnic:FcGroupTempl:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.9
cucsVnicFcGroupTemplNwTemplNameCisco UCS vnic:FcGroupTempl:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.10
cucsVnicFcGroupTemplOperStatsPolicyNameCisco UCS vnic:FcGroupTempl:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.11
cucsVnicFcGroupTemplOperStorageConnPolicyNameCisco UCS vnic:FcGroupTempl:operStorageConnPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.12
cucsVnicFcGroupTemplPolicyLevelCisco UCS vnic:FcGroupTempl:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.49.1.13
cucsVnicFcGroupTemplPolicyOwnerCisco UCS vnic:FcGroupTempl:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.14
cucsVnicFcGroupTemplQosPolicyNameCisco UCS vnic:FcGroupTempl:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.15
cucsVnicFcGroupTemplStatsPolicyNameCisco UCS vnic:FcGroupTempl:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.16
cucsVnicFcGroupTemplStorageConnPolicyNameCisco UCS vnic:FcGroupTempl:storageConnPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.17
cucsVnicFcGroupTemplTemplTypeCisco UCS vnic:FcGroupTempl:templType managed object propertyro
CucsVnicTemplateType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.18
cucsVnicFcGroupTemplRedundancyPairTypeCisco UCS vnic:FcGroupTempl:redundancyPairType managed object propertyro
CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.49.1.19
cucsVnicIScsiBootParamsTableCisco UCS vnic:IScsiBootParams managed object table
SEQUENCE OF CucsVnicIScsiBootParamsEntry
.1.3.6.1.4.1.9.9.719.1.53.50
cucsVnicIScsiBootParamsEntryEntry for the cucsVnicIScsiBootParamsTable table.
CucsVnicIScsiBootParamsEntry
.1.3.6.1.4.1.9.9.719.1.53.50.1
cucsVnicIScsiBootParamsInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.50.1.1
cucsVnicIScsiBootParamsDnCisco UCS vnic:IScsiBootParams:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.50.1.2
cucsVnicIScsiBootParamsRnCisco UCS vnic:IScsiBootParams:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.50.1.3
cucsVnicIScsiBootParamsDescrCisco UCS vnic:IScsiBootParams:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.50.1.4
cucsVnicIScsiBootParamsIntIdCisco UCS vnic:IScsiBootParams:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.50.1.5
cucsVnicIScsiBootParamsNameCisco UCS vnic:IScsiBootParams:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.50.1.6
cucsVnicIScsiBootParamsPolicyLevelCisco UCS vnic:IScsiBootParams:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.50.1.7
cucsVnicIScsiBootParamsPolicyOwnerCisco UCS vnic:IScsiBootParams:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.50.1.8
cucsVnicIScsiBootParamsOwnerCisco UCS vnic:IScsiBootParams:owner managed object propertyro
CucsLsOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.50.1.9
cucsVnicIScsiBootParamsPropAclCisco UCS vnic:IScsiBootParams:propAcl managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.50.1.10
cucsVnicIScsiBootVnicTableCisco UCS vnic:IScsiBootVnic managed object table
SEQUENCE OF CucsVnicIScsiBootVnicEntry
.1.3.6.1.4.1.9.9.719.1.53.51
cucsVnicIScsiBootVnicEntryEntry for the cucsVnicIScsiBootVnicTable table.
CucsVnicIScsiBootVnicEntry
.1.3.6.1.4.1.9.9.719.1.53.51.1
cucsVnicIScsiBootVnicInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.1
cucsVnicIScsiBootVnicDnCisco UCS vnic:IScsiBootVnic:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.2
cucsVnicIScsiBootVnicRnCisco UCS vnic:IScsiBootVnic:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.3
cucsVnicIScsiBootVnicAuthProfileNameCisco UCS vnic:IScsiBootVnic:authProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.4
cucsVnicIScsiBootVnicDescrCisco UCS vnic:IScsiBootVnic:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.5
cucsVnicIScsiBootVnicInitiatorNameCisco UCS vnic:IScsiBootVnic:initiatorName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.6
cucsVnicIScsiBootVnicIntIdCisco UCS vnic:IScsiBootVnic:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.7
cucsVnicIScsiBootVnicIqnIdentPoolNameCisco UCS vnic:IScsiBootVnic:iqnIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.8
cucsVnicIScsiBootVnicNameCisco UCS vnic:IScsiBootVnic:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.9
cucsVnicIScsiBootVnicOperAuthProfileNameCisco UCS vnic:IScsiBootVnic:operAuthProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.10
cucsVnicIScsiBootVnicOperIqnIdentPoolNameCisco UCS vnic:IScsiBootVnic:operIqnIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.11
cucsVnicIScsiBootVnicPolicyLevelCisco UCS vnic:IScsiBootVnic:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.51.1.12
cucsVnicIScsiBootVnicPolicyOwnerCisco UCS vnic:IScsiBootVnic:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.51.1.13
cucsVnicIScsiLCPTableCisco UCS vnic:IScsiLCP managed object table
SEQUENCE OF CucsVnicIScsiLCPEntry
.1.3.6.1.4.1.9.9.719.1.53.52
cucsVnicIScsiLCPEntryEntry for the cucsVnicIScsiLCPTable table.
CucsVnicIScsiLCPEntry
.1.3.6.1.4.1.9.9.719.1.53.52.1
cucsVnicIScsiLCPInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.1
cucsVnicIScsiLCPDnCisco UCS vnic:IScsiLCP:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.2
cucsVnicIScsiLCPRnCisco UCS vnic:IScsiLCP:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.3
cucsVnicIScsiLCPAdaptorProfileNameCisco UCS vnic:IScsiLCP:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.4
cucsVnicIScsiLCPAddrCisco UCS vnic:IScsiLCP:addr managed object propertyro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.52.1.5
cucsVnicIScsiLCPAdminVconCisco UCS vnic:IScsiLCP:adminVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.6
cucsVnicIScsiLCPBootDevCisco UCS vnic:IScsiLCP:bootDev managed object propertyro
CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.7
cucsVnicIScsiLCPConfigQualifierCisco UCS vnic:IScsiLCP:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.8
cucsVnicIScsiLCPConfigStateCisco UCS vnic:IScsiLCP:configState managed object propertyro
CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.9
cucsVnicIScsiLCPEquipmentDnCisco UCS vnic:IScsiLCP:equipmentDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.10
cucsVnicIScsiLCPFltAggrCisco UCS vnic:IScsiLCP:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.52.1.11
cucsVnicIScsiLCPIdentPoolNameCisco UCS vnic:IScsiLCP:identPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.12
cucsVnicIScsiLCPInstTypeCisco UCS vnic:IScsiLCP:instType managed object propertyro
CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.13
cucsVnicIScsiLCPNameCisco UCS vnic:IScsiLCP:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.14
cucsVnicIScsiLCPNwTemplNameCisco UCS vnic:IScsiLCP:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.15
cucsVnicIScsiLCPOperAdaptorProfileNameCisco UCS vnic:IScsiLCP:operAdaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.16
cucsVnicIScsiLCPOperIdentPoolNameCisco UCS vnic:IScsiLCP:operIdentPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.17
cucsVnicIScsiLCPOperOrderCisco UCS vnic:IScsiLCP:operOrder managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.52.1.18
cucsVnicIScsiLCPOperSpeedCisco UCS vnic:IScsiLCP:operSpeed managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.52.1.19
cucsVnicIScsiLCPOperStatsPolicyNameCisco UCS vnic:IScsiLCP:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.20
cucsVnicIScsiLCPOperVconCisco UCS vnic:IScsiLCP:operVcon managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.21
cucsVnicIScsiLCPOrderCisco UCS vnic:IScsiLCP:order managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.52.1.22
cucsVnicIScsiLCPOwnerCisco UCS vnic:IScsiLCP:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.23
cucsVnicIScsiLCPPinToGroupNameCisco UCS vnic:IScsiLCP:pinToGroupName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.24
cucsVnicIScsiLCPQosPolicyNameCisco UCS vnic:IScsiLCP:qosPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.25
cucsVnicIScsiLCPStatsPolicyNameCisco UCS vnic:IScsiLCP:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.26
cucsVnicIScsiLCPSwitchIdCisco UCS vnic:IScsiLCP:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.27
cucsVnicIScsiLCPTypeCisco UCS vnic:IScsiLCP:type managed object propertyro
CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.28
cucsVnicIScsiLCPVnicNameCisco UCS vnic:IScsiLCP:vnicName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.29
cucsVnicIScsiLCPAdminHostPortCisco UCS vnic:IScsiLCP:adminHostPort managed object propertyro
CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.31
cucsVnicIScsiLCPOperHostPortCisco UCS vnic:IScsiLCP:operHostPort managed object propertyro
CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.32
cucsVnicIScsiLCPAdminCdnNameCisco UCS vnic:IScsiLCP:adminCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.33
cucsVnicIScsiLCPOperCdnNameCisco UCS vnic:IScsiLCP:operCdnName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.34
cucsVnicIScsiLCPCdnSourceCisco UCS vnic:IScsiLCP:cdnSource managed object propertyro
CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.35
cucsVnicIScsiLCPCdnPropInSyncCisco UCS vnic:IScsiLCP:cdnPropInSync managed object propertyro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.52.1.36
cucsVnicIScsiLCPRedundancyPairTypeCisco UCS vnic:IScsiLCP:redundancyPairType managed object propertyro
CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.37
cucsVnicIScsiLCPRedundancyPeerCisco UCS vnic:IScsiLCP:redundancyPeer managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.52.1.38
cucsVnicLanConnPolicyTableCisco UCS vnic:LanConnPolicy managed object table
SEQUENCE OF CucsVnicLanConnPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.53
cucsVnicLanConnPolicyEntryEntry for the cucsVnicLanConnPolicyTable table.
CucsVnicLanConnPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.53.1
cucsVnicLanConnPolicyInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.53.1.1
cucsVnicLanConnPolicyDnCisco UCS vnic:LanConnPolicy:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.53.1.2
cucsVnicLanConnPolicyRnCisco UCS vnic:LanConnPolicy:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.53.1.3
cucsVnicLanConnPolicyDescrCisco UCS vnic:LanConnPolicy:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.53.1.4
cucsVnicLanConnPolicyFltAggrCisco UCS vnic:LanConnPolicy:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.53.1.5
cucsVnicLanConnPolicyIntIdCisco UCS vnic:LanConnPolicy:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.53.1.6
cucsVnicLanConnPolicyNameCisco UCS vnic:LanConnPolicy:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.53.1.7
cucsVnicLanConnPolicyPolicyLevelCisco UCS vnic:LanConnPolicy:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.53.1.8
cucsVnicLanConnPolicyPolicyOwnerCisco UCS vnic:LanConnPolicy:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.53.1.9
cucsVnicProfileSetFsmTableCisco UCS vnic:ProfileSetFsm managed object table
SEQUENCE OF CucsVnicProfileSetFsmEntry
.1.3.6.1.4.1.9.9.719.1.53.54
cucsVnicProfileSetFsmEntryEntry for the cucsVnicProfileSetFsmTable table.
CucsVnicProfileSetFsmEntry
.1.3.6.1.4.1.9.9.719.1.53.54.1
cucsVnicProfileSetFsmInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.54.1.1
cucsVnicProfileSetFsmDnCisco UCS vnic:ProfileSetFsm:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.54.1.2
cucsVnicProfileSetFsmRnCisco UCS vnic:ProfileSetFsm:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.54.1.3
cucsVnicProfileSetFsmCompletionTimeCisco UCS vnic:ProfileSetFsm:completionTime managed object propertyro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.54.1.4
cucsVnicProfileSetFsmCurrentFsmCisco UCS vnic:ProfileSetFsm:currentFsm managed object propertyro
CucsVnicProfileSetFsmCurrentFsm (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.54.1.5
cucsVnicProfileSetFsmDescrDataCisco UCS vnic:ProfileSetFsm:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.54.1.6
cucsVnicProfileSetFsmFsmStatusCisco UCS vnic:ProfileSetFsm:fsmStatus managed object propertyro
CucsFsmFsmStageStatus (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.54.1.7
cucsVnicProfileSetFsmProgressCisco UCS vnic:ProfileSetFsm:progress managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.54.1.8
cucsVnicProfileSetFsmRmtErrCodeCisco UCS vnic:ProfileSetFsm:rmtErrCode managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.54.1.9
cucsVnicProfileSetFsmRmtErrDescrCisco UCS vnic:ProfileSetFsm:rmtErrDescr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.54.1.10
cucsVnicProfileSetFsmRmtRsltCisco UCS vnic:ProfileSetFsm:rmtRslt managed object propertyro
CucsConditionRemoteInvRslt (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.54.1.11
cucsVnicProfileSetFsmStageTableCisco UCS vnic:ProfileSetFsmStage managed object table
SEQUENCE OF CucsVnicProfileSetFsmStageEntry
.1.3.6.1.4.1.9.9.719.1.53.55
cucsVnicProfileSetFsmStageEntryEntry for the cucsVnicProfileSetFsmStageTable table.
CucsVnicProfileSetFsmStageEntry
.1.3.6.1.4.1.9.9.719.1.53.55.1
cucsVnicProfileSetFsmStageInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.55.1.1
cucsVnicProfileSetFsmStageDnCisco UCS vnic:ProfileSetFsmStage:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.55.1.2
cucsVnicProfileSetFsmStageRnCisco UCS vnic:ProfileSetFsmStage:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.55.1.3
cucsVnicProfileSetFsmStageDescrDataCisco UCS vnic:ProfileSetFsmStage:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.55.1.4
cucsVnicProfileSetFsmStageLastUpdateTimeCisco UCS vnic:ProfileSetFsmStage:lastUpdateTime managed object propertyro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.55.1.5
cucsVnicProfileSetFsmStageNameCisco UCS vnic:ProfileSetFsmStage:name managed object propertyro
CucsVnicProfileSetFsmStageName (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.55.1.6
cucsVnicProfileSetFsmStageOrderCisco UCS vnic:ProfileSetFsmStage:order managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.55.1.7
cucsVnicProfileSetFsmStageRetryCisco UCS vnic:ProfileSetFsmStage:retry managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.55.1.8
cucsVnicProfileSetFsmStageStageStatusCisco UCS vnic:ProfileSetFsmStage:stageStatus managed object propertyro
CucsFsmFsmStageStatus (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.55.1.9
cucsVnicRackServerDiscoveryProfileTableCisco UCS vnic:RackServerDiscoveryProfile managed object table
SEQUENCE OF CucsVnicRackServerDiscoveryProfileEntry
.1.3.6.1.4.1.9.9.719.1.53.56
cucsVnicRackServerDiscoveryProfileEntryEntry for the cucsVnicRackServerDiscoveryProfileTable table.
CucsVnicRackServerDiscoveryProfileEntry
.1.3.6.1.4.1.9.9.719.1.53.56.1
cucsVnicRackServerDiscoveryProfileInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.56.1.1
cucsVnicRackServerDiscoveryProfileDnCisco UCS vnic:RackServerDiscoveryProfile:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.56.1.2
cucsVnicRackServerDiscoveryProfileRnCisco UCS vnic:RackServerDiscoveryProfile:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.56.1.3
cucsVnicRackServerDiscoveryProfileDescrCisco UCS vnic:RackServerDiscoveryProfile:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.56.1.4
cucsVnicRackServerDiscoveryProfileIntIdCisco UCS vnic:RackServerDiscoveryProfile:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.56.1.5
cucsVnicRackServerDiscoveryProfileMaxPortsCisco UCS vnic:RackServerDiscoveryProfile:maxPorts managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.56.1.6
cucsVnicRackServerDiscoveryProfileNameCisco UCS vnic:RackServerDiscoveryProfile:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.56.1.7
cucsVnicRackServerDiscoveryProfilePolicyLevelCisco UCS vnic:RackServerDiscoveryProfile:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.56.1.8
cucsVnicRackServerDiscoveryProfilePolicyOwnerCisco UCS vnic:RackServerDiscoveryProfile:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.56.1.9
cucsVnicSanConnPolicyTableCisco UCS vnic:SanConnPolicy managed object table
SEQUENCE OF CucsVnicSanConnPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.57
cucsVnicSanConnPolicyEntryEntry for the cucsVnicSanConnPolicyTable table.
CucsVnicSanConnPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.57.1
cucsVnicSanConnPolicyInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.57.1.1
cucsVnicSanConnPolicyDnCisco UCS vnic:SanConnPolicy:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.57.1.2
cucsVnicSanConnPolicyRnCisco UCS vnic:SanConnPolicy:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.57.1.3
cucsVnicSanConnPolicyDescrCisco UCS vnic:SanConnPolicy:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.57.1.4
cucsVnicSanConnPolicyFltAggrCisco UCS vnic:SanConnPolicy:fltAggr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.57.1.5
cucsVnicSanConnPolicyIntIdCisco UCS vnic:SanConnPolicy:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.57.1.6
cucsVnicSanConnPolicyNameCisco UCS vnic:SanConnPolicy:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.57.1.7
cucsVnicSanConnPolicyPolicyLevelCisco UCS vnic:SanConnPolicy:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.57.1.8
cucsVnicSanConnPolicyPolicyOwnerCisco UCS vnic:SanConnPolicy:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.57.1.9
cucsVnicVhbaBehPolicyTableCisco UCS vnic:VhbaBehPolicy managed object table
SEQUENCE OF CucsVnicVhbaBehPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.58
cucsVnicVhbaBehPolicyEntryEntry for the cucsVnicVhbaBehPolicyTable table.
CucsVnicVhbaBehPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.58.1
cucsVnicVhbaBehPolicyInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.58.1.1
cucsVnicVhbaBehPolicyDnCisco UCS vnic:VhbaBehPolicy:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.58.1.2
cucsVnicVhbaBehPolicyRnCisco UCS vnic:VhbaBehPolicy:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.58.1.3
cucsVnicVhbaBehPolicyActionCisco UCS vnic:VhbaBehPolicy:action managed object propertyro
CucsVnicDefaultAction (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.58.1.4
cucsVnicVhbaBehPolicyDescrCisco UCS vnic:VhbaBehPolicy:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.58.1.5
cucsVnicVhbaBehPolicyIntIdCisco UCS vnic:VhbaBehPolicy:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.58.1.6
cucsVnicVhbaBehPolicyNameCisco UCS vnic:VhbaBehPolicy:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.58.1.7
cucsVnicVhbaBehPolicyNwTemplNameCisco UCS vnic:VhbaBehPolicy:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.58.1.8
cucsVnicVhbaBehPolicyPolicyLevelCisco UCS vnic:VhbaBehPolicy:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.58.1.9
cucsVnicVhbaBehPolicyPolicyOwnerCisco UCS vnic:VhbaBehPolicy:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.58.1.10
cucsVnicVhbaBehPolicyTypeCisco UCS vnic:VhbaBehPolicy:type managed object propertyro
CucsVnicVhbaBehPolicyType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.58.1.11
cucsVnicVnicBehPolicyTableCisco UCS vnic:VnicBehPolicy managed object table
SEQUENCE OF CucsVnicVnicBehPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.59
cucsVnicVnicBehPolicyEntryEntry for the cucsVnicVnicBehPolicyTable table.
CucsVnicVnicBehPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.59.1
cucsVnicVnicBehPolicyInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.59.1.1
cucsVnicVnicBehPolicyDnCisco UCS vnic:VnicBehPolicy:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.59.1.2
cucsVnicVnicBehPolicyRnCisco UCS vnic:VnicBehPolicy:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.59.1.3
cucsVnicVnicBehPolicyActionCisco UCS vnic:VnicBehPolicy:action managed object propertyro
CucsVnicDefaultAction (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.59.1.4
cucsVnicVnicBehPolicyDescrCisco UCS vnic:VnicBehPolicy:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.59.1.5
cucsVnicVnicBehPolicyIntIdCisco UCS vnic:VnicBehPolicy:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.59.1.6
cucsVnicVnicBehPolicyNameCisco UCS vnic:VnicBehPolicy:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.59.1.7
cucsVnicVnicBehPolicyNwTemplNameCisco UCS vnic:VnicBehPolicy:nwTemplName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.59.1.8
cucsVnicVnicBehPolicyPolicyLevelCisco UCS vnic:VnicBehPolicy:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.59.1.9
cucsVnicVnicBehPolicyPolicyOwnerCisco UCS vnic:VnicBehPolicy:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.59.1.10
cucsVnicVnicBehPolicyTypeCisco UCS vnic:VnicBehPolicy:type managed object propertyro
CucsVnicVnicBehPolicyType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.59.1.11
cucsVnicIpV4HistoryTableCisco UCS vnic:IpV4History managed object table
SEQUENCE OF CucsVnicIpV4HistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.60
cucsVnicIpV4HistoryEntryEntry for the cucsVnicIpV4HistoryTable table.
CucsVnicIpV4HistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.60.1
cucsVnicIpV4HistoryInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.60.1.1
cucsVnicIpV4HistoryDnCisco UCS vnic:IpV4History:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.60.1.2
cucsVnicIpV4HistoryRnCisco UCS vnic:IpV4History:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.60.1.3
cucsVnicIpV4HistoryOldIpV4AddrCisco UCS vnic:IpV4History:oldIpV4Addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.60.1.4
cucsVnicIqnHistoryTableCisco UCS vnic:IqnHistory managed object table
SEQUENCE OF CucsVnicIqnHistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.61
cucsVnicIqnHistoryEntryEntry for the cucsVnicIqnHistoryTable table.
CucsVnicIqnHistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.61.1
cucsVnicIqnHistoryInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.61.1.1
cucsVnicIqnHistoryDnCisco UCS vnic:IqnHistory:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.61.1.2
cucsVnicIqnHistoryRnCisco UCS vnic:IqnHistory:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.61.1.3
cucsVnicIqnHistoryOldInitiatorNameCisco UCS vnic:IqnHistory:oldInitiatorName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.61.1.4
cucsVnicMacHistoryTableCisco UCS vnic:MacHistory managed object table
SEQUENCE OF CucsVnicMacHistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.62
cucsVnicMacHistoryEntryEntry for the cucsVnicMacHistoryTable table.
CucsVnicMacHistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.62.1
cucsVnicMacHistoryInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.62.1.1
cucsVnicMacHistoryDnCisco UCS vnic:MacHistory:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.62.1.2
cucsVnicMacHistoryRnCisco UCS vnic:MacHistory:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.62.1.3
cucsVnicMacHistoryOldaddrCisco UCS vnic:MacHistory:oldaddr managed object propertyro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.719.1.53.62.1.4
cucsVnicWwnnHistoryTableCisco UCS vnic:WwnnHistory managed object table
SEQUENCE OF CucsVnicWwnnHistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.63
cucsVnicWwnnHistoryEntryEntry for the cucsVnicWwnnHistoryTable table.
CucsVnicWwnnHistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.63.1
cucsVnicWwnnHistoryInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.63.1.1
cucsVnicWwnnHistoryDnCisco UCS vnic:WwnnHistory:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.63.1.2
cucsVnicWwnnHistoryRnCisco UCS vnic:WwnnHistory:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.63.1.3
cucsVnicWwnnHistoryOldwwnnCisco UCS vnic:WwnnHistory:oldwwnn managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.63.1.4
cucsVnicWwpnHistoryTableCisco UCS vnic:WwpnHistory managed object table
SEQUENCE OF CucsVnicWwpnHistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.64
cucsVnicWwpnHistoryEntryEntry for the cucsVnicWwpnHistoryTable table.
CucsVnicWwpnHistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.64.1
cucsVnicWwpnHistoryInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.64.1.1
cucsVnicWwpnHistoryDnCisco UCS vnic:WwpnHistory:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.64.1.2
cucsVnicWwpnHistoryRnCisco UCS vnic:WwpnHistory:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.64.1.3
cucsVnicWwpnHistoryOldaddrCisco UCS vnic:WwpnHistory:oldaddr managed object propertyro
Unsigned64 (CISCO-TC)
.1.3.6.1.4.1.9.9.719.1.53.64.1.4
cucsVnicIpV4MgmtPooledAddrTableCisco UCS vnic:IpV4MgmtPooledAddr managed object table
SEQUENCE OF CucsVnicIpV4MgmtPooledAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.65
cucsVnicIpV4MgmtPooledAddrEntryEntry for the cucsVnicIpV4MgmtPooledAddrTable table.
CucsVnicIpV4MgmtPooledAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.65.1
cucsVnicIpV4MgmtPooledAddrInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.65.1.1
cucsVnicIpV4MgmtPooledAddrDnCisco UCS vnic:IpV4MgmtPooledAddr:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.65.1.2
cucsVnicIpV4MgmtPooledAddrRnCisco UCS vnic:IpV4MgmtPooledAddr:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.65.1.3
cucsVnicIpV4MgmtPooledAddrAddrCisco UCS vnic:IpV4MgmtPooledAddr:addr managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.65.1.4
cucsVnicIpV4MgmtPooledAddrDefGwCisco UCS vnic:IpV4MgmtPooledAddr:defGw managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.65.1.5
cucsVnicIpV4MgmtPooledAddrNameCisco UCS vnic:IpV4MgmtPooledAddr:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.65.1.6
cucsVnicIpV4MgmtPooledAddrOperNameCisco UCS vnic:IpV4MgmtPooledAddr:operName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.65.1.7
cucsVnicIpV4MgmtPooledAddrSubnetCisco UCS vnic:IpV4MgmtPooledAddr:subnet managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.65.1.8
cucsVnicIpV4MgmtPooledAddrPrimDnsCisco UCS vnic:IpV4MgmtPooledAddr:primDns managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.65.1.9
cucsVnicIpV4MgmtPooledAddrSecDnsCisco UCS vnic:IpV4MgmtPooledAddr:secDns managed object propertyro
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.65.1.10
cucsVnicIpV6MgmtPooledAddrTableCisco UCS vnic:IpV6MgmtPooledAddr managed object table
SEQUENCE OF CucsVnicIpV6MgmtPooledAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.66
cucsVnicIpV6MgmtPooledAddrEntryEntry for the cucsVnicIpV6MgmtPooledAddrTable table.
CucsVnicIpV6MgmtPooledAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.66.1
cucsVnicIpV6MgmtPooledAddrInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.66.1.1
cucsVnicIpV6MgmtPooledAddrDnCisco UCS vnic:IpV6MgmtPooledAddr:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.66.1.2
cucsVnicIpV6MgmtPooledAddrRnCisco UCS vnic:IpV6MgmtPooledAddr:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.66.1.3
cucsVnicIpV6MgmtPooledAddrAddrCisco UCS vnic:IpV6MgmtPooledAddr:addr managed object propertyro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.66.1.4
cucsVnicIpV6MgmtPooledAddrDefGwCisco UCS vnic:IpV6MgmtPooledAddr:defGw managed object propertyro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.66.1.5
cucsVnicIpV6MgmtPooledAddrNameCisco UCS vnic:IpV6MgmtPooledAddr:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.66.1.6
cucsVnicIpV6MgmtPooledAddrOperNameCisco UCS vnic:IpV6MgmtPooledAddr:operName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.66.1.7
cucsVnicIpV6MgmtPooledAddrPrefixCisco UCS vnic:IpV6MgmtPooledAddr:prefix managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.66.1.8
cucsVnicIpV6MgmtPooledAddrPrimDnsCisco UCS vnic:IpV6MgmtPooledAddr:primDns managed object propertyro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.66.1.9
cucsVnicIpV6MgmtPooledAddrSecDnsCisco UCS vnic:IpV6MgmtPooledAddr:secDns managed object propertyro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.66.1.10
cucsVnicIpV6StaticAddrTableCisco UCS vnic:IpV6StaticAddr managed object table
SEQUENCE OF CucsVnicIpV6StaticAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.67
cucsVnicIpV6StaticAddrEntryEntry for the cucsVnicIpV6StaticAddrTable table.
CucsVnicIpV6StaticAddrEntry
.1.3.6.1.4.1.9.9.719.1.53.67.1
cucsVnicIpV6StaticAddrInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.67.1.1
cucsVnicIpV6StaticAddrDnCisco UCS vnic:IpV6StaticAddr:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.67.1.2
cucsVnicIpV6StaticAddrRnCisco UCS vnic:IpV6StaticAddr:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.67.1.3
cucsVnicIpV6StaticAddrAddrCisco UCS vnic:IpV6StaticAddr:addr managed object propertyro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.67.1.4
cucsVnicIpV6StaticAddrDefGwCisco UCS vnic:IpV6StaticAddr:defGw managed object propertyro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.67.1.5
cucsVnicIpV6StaticAddrPrefixCisco UCS vnic:IpV6StaticAddr:prefix managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.67.1.6
cucsVnicIpV6StaticAddrPrimDnsCisco UCS vnic:IpV6StaticAddr:primDns managed object propertyro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.67.1.7
cucsVnicIpV6StaticAddrSecDnsCisco UCS vnic:IpV6StaticAddr:secDns managed object propertyro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.67.1.8
cucsVnicProfileRefTableCisco UCS vnic:ProfileRef managed object table
SEQUENCE OF CucsVnicProfileRefEntry
.1.3.6.1.4.1.9.9.719.1.53.68
cucsVnicProfileRefEntryEntry for the cucsVnicProfileRefTable table.
CucsVnicProfileRefEntry
.1.3.6.1.4.1.9.9.719.1.53.68.1
cucsVnicProfileRefInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.68.1.1
cucsVnicProfileRefDnCisco UCS vnic:ProfileRef:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.68.1.2
cucsVnicProfileRefRnCisco UCS vnic:ProfileRef:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.68.1.3
cucsVnicProfileRefNameCisco UCS vnic:ProfileRef:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.68.1.4
cucsVnicProfileRefSourceDnCisco UCS vnic:ProfileRef:sourceDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.68.1.5
cucsVnicUsnicConPolicyTableCisco UCS vnic:UsnicConPolicy managed object table
SEQUENCE OF CucsVnicUsnicConPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.69
cucsVnicUsnicConPolicyEntryEntry for the cucsVnicUsnicConPolicyTable table.
CucsVnicUsnicConPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.69.1
cucsVnicUsnicConPolicyInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.69.1.1
cucsVnicUsnicConPolicyDnCisco UCS vnic:UsnicConPolicy:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.69.1.2
cucsVnicUsnicConPolicyRnCisco UCS vnic:UsnicConPolicy:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.69.1.3
cucsVnicUsnicConPolicyAdaptorProfileNameCisco UCS vnic:UsnicConPolicy:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.69.1.4
cucsVnicUsnicConPolicyDescrCisco UCS vnic:UsnicConPolicy:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.69.1.5
cucsVnicUsnicConPolicyIntIdCisco UCS vnic:UsnicConPolicy:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.69.1.6
cucsVnicUsnicConPolicyNameCisco UCS vnic:UsnicConPolicy:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.69.1.7
cucsVnicUsnicConPolicyPolicyLevelCisco UCS vnic:UsnicConPolicy:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.69.1.8
cucsVnicUsnicConPolicyPolicyOwnerCisco UCS vnic:UsnicConPolicy:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.69.1.9
cucsVnicUsnicConPolicyUsnicCountCisco UCS vnic:UsnicConPolicy:usnicCount managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.69.1.10
cucsVnicUsnicConPolicyRefTableCisco UCS vnic:UsnicConPolicyRef managed object table
SEQUENCE OF CucsVnicUsnicConPolicyRefEntry
.1.3.6.1.4.1.9.9.719.1.53.70
cucsVnicUsnicConPolicyRefEntryEntry for the cucsVnicUsnicConPolicyRefTable table.
CucsVnicUsnicConPolicyRefEntry
.1.3.6.1.4.1.9.9.719.1.53.70.1
cucsVnicUsnicConPolicyRefInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.70.1.1
cucsVnicUsnicConPolicyRefDnCisco UCS vnic:UsnicConPolicyRef:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.70.1.2
cucsVnicUsnicConPolicyRefRnCisco UCS vnic:UsnicConPolicyRef:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.70.1.3
cucsVnicUsnicConPolicyRefConPolicyNameCisco UCS vnic:UsnicConPolicyRef:conPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.70.1.4
cucsVnicUsnicConPolicyRefOperConPolicyNameCisco UCS vnic:UsnicConPolicyRef:operConPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.70.1.5
cucsVnicVmqConPolicyTableCisco UCS vnic:VmqConPolicy managed object table
SEQUENCE OF CucsVnicVmqConPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.71
cucsVnicVmqConPolicyEntryEntry for the cucsVnicVmqConPolicyTable table.
CucsVnicVmqConPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.71.1
cucsVnicVmqConPolicyInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.71.1.1
cucsVnicVmqConPolicyDnCisco UCS vnic:VmqConPolicy:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.71.1.2
cucsVnicVmqConPolicyRnCisco UCS vnic:VmqConPolicy:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.71.1.3
cucsVnicVmqConPolicyDescrCisco UCS vnic:VmqConPolicy:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.71.1.4
cucsVnicVmqConPolicyIntIdCisco UCS vnic:VmqConPolicy:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.71.1.5
cucsVnicVmqConPolicyIntrCountCisco UCS vnic:VmqConPolicy:intrCount managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.71.1.6
cucsVnicVmqConPolicyNameCisco UCS vnic:VmqConPolicy:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.71.1.7
cucsVnicVmqConPolicyPolicyLevelCisco UCS vnic:VmqConPolicy:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.71.1.8
cucsVnicVmqConPolicyPolicyOwnerCisco UCS vnic:VmqConPolicy:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.71.1.9
cucsVnicVmqConPolicyVmqCountCisco UCS vnic:VmqConPolicy:vmqCount managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.71.1.10
cucsVnicVmqConPolicyRefTableCisco UCS vnic:VmqConPolicyRef managed object table
SEQUENCE OF CucsVnicVmqConPolicyRefEntry
.1.3.6.1.4.1.9.9.719.1.53.72
cucsVnicVmqConPolicyRefEntryEntry for the cucsVnicVmqConPolicyRefTable table.
CucsVnicVmqConPolicyRefEntry
.1.3.6.1.4.1.9.9.719.1.53.72.1
cucsVnicVmqConPolicyRefInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.72.1.1
cucsVnicVmqConPolicyRefDnCisco UCS vnic:VmqConPolicyRef:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.72.1.2
cucsVnicVmqConPolicyRefRnCisco UCS vnic:VmqConPolicyRef:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.72.1.3
cucsVnicVmqConPolicyRefConPolicyNameCisco UCS vnic:VmqConPolicyRef:conPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.72.1.4
cucsVnicVmqConPolicyRefOperConPolicyNameCisco UCS vnic:VmqConPolicyRef:operConPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.72.1.5
cucsVnicIpV6HistoryTableCisco UCS vnic:IpV6History managed object table
SEQUENCE OF CucsVnicIpV6HistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.73
cucsVnicIpV6HistoryEntryEntry for the cucsVnicIpV6HistoryTable table.
CucsVnicIpV6HistoryEntry
.1.3.6.1.4.1.9.9.719.1.53.73.1
cucsVnicIpV6HistoryInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.73.1.1
cucsVnicIpV6HistoryDnCisco UCS vnic:IpV6History:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.73.1.2
cucsVnicIpV6HistoryRnCisco UCS vnic:IpV6History:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.73.1.3
cucsVnicIpV6HistoryOldIpV6AddrCisco UCS vnic:IpV6History:oldIpV6Addr managed object propertyro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.73.1.4
cucsVnicEthConfigTableCisco UCS vnic:EthConfig managed object table
SEQUENCE OF CucsVnicEthConfigEntry
.1.3.6.1.4.1.9.9.719.1.53.74
cucsVnicEthConfigEntryEntry for the cucsVnicEthConfigTable table.
CucsVnicEthConfigEntry
.1.3.6.1.4.1.9.9.719.1.53.74.1
cucsVnicEthConfigInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.1
cucsVnicEthConfigDnCisco UCS vnic:EthConfig:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.2
cucsVnicEthConfigRnCisco UCS vnic:EthConfig:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.3
cucsVnicEthConfigAdaptorProfileNameCisco UCS vnic:EthConfig:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.4
cucsVnicEthConfigMacPoolNameCisco UCS vnic:EthConfig:macPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.5
cucsVnicEthConfigNwCtrlPolicyNameCisco UCS vnic:EthConfig:nwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.6
cucsVnicEthConfigOperAdaptorProfileNameCisco UCS vnic:EthConfig:operAdaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.7
cucsVnicEthConfigOperMacPoolNameCisco UCS vnic:EthConfig:operMacPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.8
cucsVnicEthConfigOperNwCtrlPolicyNameCisco UCS vnic:EthConfig:operNwCtrlPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.9
cucsVnicEthConfigOperStatsPolicyNameCisco UCS vnic:EthConfig:operStatsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.10
cucsVnicEthConfigStatsPolicyNameCisco UCS vnic:EthConfig:statsPolicyName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.74.1.11
cucsVnicIPv6IfTableCisco UCS vnic:IPv6If managed object table
SEQUENCE OF CucsVnicIPv6IfEntry
.1.3.6.1.4.1.9.9.719.1.53.75
cucsVnicIPv6IfEntryEntry for the cucsVnicIPv6IfTable table.
CucsVnicIPv6IfEntry
.1.3.6.1.4.1.9.9.719.1.53.75.1
cucsVnicIPv6IfInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.1
cucsVnicIPv6IfDnCisco UCS vnic:IPv6If:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.2
cucsVnicIPv6IfRnCisco UCS vnic:IPv6If:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.3
cucsVnicIPv6IfAddrCisco UCS vnic:IPv6If:addr managed object propertyro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.4
cucsVnicIPv6IfConfigQualifierCisco UCS vnic:IPv6If:configQualifier managed object propertyro
CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.5
cucsVnicIPv6IfNameCisco UCS vnic:IPv6If:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.6
cucsVnicIPv6IfOperStateCisco UCS vnic:IPv6If:operState managed object propertyro
CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.7
cucsVnicIPv6IfOperVnetDnCisco UCS vnic:IPv6If:operVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.8
cucsVnicIPv6IfOperVnetNameCisco UCS vnic:IPv6If:operVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.9
cucsVnicIPv6IfOwnerCisco UCS vnic:IPv6If:owner managed object propertyro
CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.10
cucsVnicIPv6IfPubNwIdCisco UCS vnic:IPv6If:pubNwId managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.75.1.11
cucsVnicIPv6IfSharingCisco UCS vnic:IPv6If:sharing managed object propertyro
CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.12
cucsVnicIPv6IfSwitchIdCisco UCS vnic:IPv6If:switchId managed object propertyro
CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.13
cucsVnicIPv6IfTypeCisco UCS vnic:IPv6If:type managed object propertyro
CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.14
cucsVnicIPv6IfVnetCisco UCS vnic:IPv6If:vnet managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.75.1.15
cucsVnicIPv6IfOperPrimaryVnetDnCisco UCS vnic:IPv6If:operPrimaryVnetDn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.16
cucsVnicIPv6IfOperPrimaryVnetNameCisco UCS vnic:IPv6If:operPrimaryVnetName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.75.1.17
cucsVnicIScsiConfigTableCisco UCS vnic:IScsiConfig managed object table
SEQUENCE OF CucsVnicIScsiConfigEntry
.1.3.6.1.4.1.9.9.719.1.53.76
cucsVnicIScsiConfigEntryEntry for the cucsVnicIScsiConfigTable table.
CucsVnicIScsiConfigEntry
.1.3.6.1.4.1.9.9.719.1.53.76.1
cucsVnicIScsiConfigInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.1
cucsVnicIScsiConfigDnCisco UCS vnic:IScsiConfig:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.2
cucsVnicIScsiConfigRnCisco UCS vnic:IScsiConfig:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.3
cucsVnicIScsiConfigAdaptorProfileNameCisco UCS vnic:IScsiConfig:adaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.4
cucsVnicIScsiConfigIpPoolNameCisco UCS vnic:IScsiConfig:ipPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.5
cucsVnicIScsiConfigIpPoolNameFabricBCisco UCS vnic:IScsiConfig:ipPoolNameFabricB managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.6
cucsVnicIScsiConfigIpPoolTypeCisco UCS vnic:IScsiConfig:ipPoolType managed object propertyro
CucsVnicIpPoolType (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.7
cucsVnicIScsiConfigIqnPoolNameCisco UCS vnic:IScsiConfig:iqnPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.8
cucsVnicIScsiConfigOperAdaptorProfileNameCisco UCS vnic:IScsiConfig:operAdaptorProfileName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.9
cucsVnicIScsiConfigOperIpPoolNameCisco UCS vnic:IScsiConfig:operIpPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.10
cucsVnicIScsiConfigOperIpPoolNameFabricBCisco UCS vnic:IScsiConfig:operIpPoolNameFabricB managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.11
cucsVnicIScsiConfigOperIqnPoolNameCisco UCS vnic:IScsiConfig:operIqnPoolName managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.76.1.12
cucsVnicIScsiInitAutoConfigPolicyTableCisco UCS vnic:IScsiInitAutoConfigPolicy managed object table
SEQUENCE OF CucsVnicIScsiInitAutoConfigPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.77
cucsVnicIScsiInitAutoConfigPolicyEntryEntry for the cucsVnicIScsiInitAutoConfigPolicyTable table.
CucsVnicIScsiInitAutoConfigPolicyEntry
.1.3.6.1.4.1.9.9.719.1.53.77.1
cucsVnicIScsiInitAutoConfigPolicyInstanceIdInstance identifier of the managed object.
CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.77.1.1
cucsVnicIScsiInitAutoConfigPolicyDnCisco UCS vnic:IScsiInitAutoConfigPolicy:dn managed object propertyro
CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB)
.1.3.6.1.4.1.9.9.719.1.53.77.1.2
cucsVnicIScsiInitAutoConfigPolicyRnCisco UCS vnic:IScsiInitAutoConfigPolicy:rn managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.77.1.3
cucsVnicIScsiInitAutoConfigPolicyDescrCisco UCS vnic:IScsiInitAutoConfigPolicy:descr managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.77.1.4
cucsVnicIScsiInitAutoConfigPolicyFabricPathCisco UCS vnic:IScsiInitAutoConfigPolicy:fabricPath managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.77.1.5
cucsVnicIScsiInitAutoConfigPolicyIntIdCisco UCS vnic:IScsiInitAutoConfigPolicy:intId managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.77.1.6
cucsVnicIScsiInitAutoConfigPolicyNameCisco UCS vnic:IScsiInitAutoConfigPolicy:name managed object propertyro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.719.1.53.77.1.7
cucsVnicIScsiInitAutoConfigPolicyPolicyLevelCisco UCS vnic:IScsiInitAutoConfigPolicy:policyLevel managed object propertyro
Gauge32
.1.3.6.1.4.1.9.9.719.1.53.77.1.8
cucsVnicIScsiInitAutoConfigPolicyPolicyOwnerCisco UCS vnic:IScsiInitAutoConfigPolicy:policyOwner managed object propertyro
CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB)
.1.3.6.1.4.1.9.9.719.1.53.77.1.9
CISCO-UNIFIED-COMPUTING-VNIC-MIB - SNMP MIB Reference | MIBs Explorer