CISCO-UNIFIED-COMPUTING-VNIC-MIB
AI MIB Summary
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
MIB representation of the Cisco Unified Computing System VNIC management information model package
Main OID:
cucsVnicObjects.1.3.6.1.4.1.9.9.719.1.53
1161
Objects
Active
Status
8
Dependencies
Imported Objects
Objects
1161 total| Object Name |
|---|
cucsVnicObjectsMIB representation of the Cisco Unified Computing System
VNIC management information model package MODULE-IDENTITY .1.3.6.1.4.1.9.9.719.1.53 |
cucsVnicBootTargetTableCisco UCS vnic:BootTarget managed object table SEQUENCE OF CucsVnicBootTargetEntry .1.3.6.1.4.1.9.9.719.1.53.1 |
cucsVnicBootTargetEntryEntry for the cucsVnicBootTargetTable table. CucsVnicBootTargetEntry .1.3.6.1.4.1.9.9.719.1.53.1.1 |
cucsVnicBootTargetInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.1.1.1 |
cucsVnicBootTargetDnCisco UCS vnic:BootTarget:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.1.1.2 |
cucsVnicBootTargetRnCisco UCS vnic:BootTarget:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.1.1.3 |
cucsVnicBootTargetLunCisco UCS vnic:BootTarget:lun managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.1.1.4 |
cucsVnicBootTargetWwnCisco UCS vnic:BootTarget:wwn managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.1.1.5 |
cucsVnicDefBehTableCisco UCS vnic:DefBeh managed object table SEQUENCE OF CucsVnicDefBehEntry .1.3.6.1.4.1.9.9.719.1.53.2 |
cucsVnicDefBehEntryEntry for the cucsVnicDefBehTable table. CucsVnicDefBehEntry .1.3.6.1.4.1.9.9.719.1.53.2.1 |
cucsVnicDefBehInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.2.1.1 |
cucsVnicDefBehDnCisco UCS vnic:DefBeh:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.2.1.2 |
cucsVnicDefBehRnCisco UCS vnic:DefBeh:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.2.1.3 |
cucsVnicDefBehActionCisco UCS vnic:DefBeh:action managed object propertyro CucsVnicDefaultAction (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.2.1.4 |
cucsVnicDefBehNwTemplNameCisco UCS vnic:DefBeh:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.2.1.5 |
cucsVnicDefBehTypeCisco UCS vnic:DefBeh:type managed object propertyro CucsVnicDefBehType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.2.1.6 |
cucsVnicDefBehDescrCisco UCS vnic:DefBeh:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.2.1.7 |
cucsVnicDefBehIntIdCisco UCS vnic:DefBeh:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.2.1.8 |
cucsVnicDefBehNameCisco UCS vnic:DefBeh:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.2.1.9 |
cucsVnicDefBehPolicyLevelCisco UCS vnic:DefBeh:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.2.1.10 |
cucsVnicDefBehPolicyOwnerCisco UCS vnic:DefBeh:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.2.1.11 |
cucsVnicDynamicConTableCisco UCS vnic:DynamicCon managed object table SEQUENCE OF CucsVnicDynamicConEntry .1.3.6.1.4.1.9.9.719.1.53.3 |
cucsVnicDynamicConEntryEntry for the cucsVnicDynamicConTable table. CucsVnicDynamicConEntry .1.3.6.1.4.1.9.9.719.1.53.3.1 |
cucsVnicDynamicConInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.3.1.1 |
cucsVnicDynamicConDnCisco UCS vnic:DynamicCon:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.3.1.2 |
cucsVnicDynamicConRnCisco UCS vnic:DynamicCon:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.3.1.3 |
cucsVnicDynamicConAdaptorProfileNameCisco UCS vnic:DynamicCon:adaptorProfileName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.3.1.4 |
cucsVnicDynamicConDescrCisco UCS vnic:DynamicCon:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.3.1.5 |
cucsVnicDynamicConDynamicEthCisco UCS vnic:DynamicCon:dynamicEth managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.3.1.6 |
cucsVnicDynamicConIntIdCisco UCS vnic:DynamicCon:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.3.1.7 |
cucsVnicDynamicConMtuCisco UCS vnic:DynamicCon:mtu managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.3.1.8 |
cucsVnicDynamicConNameCisco UCS vnic:DynamicCon:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.3.1.9 |
cucsVnicDynamicConNamingPrefixCisco UCS vnic:DynamicCon:namingPrefix managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.3.1.10 |
cucsVnicDynamicConProtectionCisco UCS vnic:DynamicCon:protection managed object propertyro CucsVnicDynamicConReqProtection (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.3.1.11 |
cucsVnicDynamicConPolicyLevelCisco UCS vnic:DynamicCon:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.3.1.12 |
cucsVnicDynamicConPolicyOwnerCisco UCS vnic:DynamicCon:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.3.1.13 |
cucsVnicDynamicConPolicyTableCisco UCS vnic:DynamicConPolicy managed object table SEQUENCE OF CucsVnicDynamicConPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.4 |
cucsVnicDynamicConPolicyEntryEntry for the cucsVnicDynamicConPolicyTable table. CucsVnicDynamicConPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.4.1 |
cucsVnicDynamicConPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.4.1.1 |
cucsVnicDynamicConPolicyDnCisco UCS vnic:DynamicConPolicy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.4.1.2 |
cucsVnicDynamicConPolicyRnCisco UCS vnic:DynamicConPolicy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.4.1.3 |
cucsVnicDynamicConPolicyAdaptorProfileNameCisco UCS vnic:DynamicConPolicy:adaptorProfileName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.4.1.4 |
cucsVnicDynamicConPolicyDescrCisco UCS vnic:DynamicConPolicy:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.4.1.5 |
cucsVnicDynamicConPolicyDynamicEthCisco UCS vnic:DynamicConPolicy:dynamicEth managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.4.1.6 |
cucsVnicDynamicConPolicyIntIdCisco UCS vnic:DynamicConPolicy:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.4.1.7 |
cucsVnicDynamicConPolicyMtuCisco UCS vnic:DynamicConPolicy:mtu managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.4.1.8 |
cucsVnicDynamicConPolicyNameCisco UCS vnic:DynamicConPolicy:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.4.1.9 |
cucsVnicDynamicConPolicyNamingPrefixCisco UCS vnic:DynamicConPolicy:namingPrefix managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.4.1.10 |
cucsVnicDynamicConPolicyProtectionCisco UCS vnic:DynamicConPolicy:protection managed
object propertyro CucsVnicDynamicConReqProtection (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.4.1.11 |
cucsVnicDynamicConPolicyPolicyLevelCisco UCS vnic:DynamicConPolicy:policyLevel managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.4.1.12 |
cucsVnicDynamicConPolicyPolicyOwnerCisco UCS vnic:DynamicConPolicy:policyOwner managed
object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.4.1.13 |
cucsVnicDynamicIdUniverseTableCisco UCS vnic:DynamicIdUniverse managed object table SEQUENCE OF CucsVnicDynamicIdUniverseEntry .1.3.6.1.4.1.9.9.719.1.53.5 |
cucsVnicDynamicIdUniverseEntryEntry for the cucsVnicDynamicIdUniverseTable table. CucsVnicDynamicIdUniverseEntry .1.3.6.1.4.1.9.9.719.1.53.5.1 |
cucsVnicDynamicIdUniverseInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.5.1.1 |
cucsVnicDynamicIdUniverseDnCisco UCS vnic:DynamicIdUniverse:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.5.1.2 |
cucsVnicDynamicIdUniverseRnCisco UCS vnic:DynamicIdUniverse:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.5.1.3 |
cucsVnicDynamicIdUniverseDescrCisco UCS vnic:DynamicIdUniverse:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.5.1.4 |
cucsVnicDynamicIdUniverseIntIdCisco UCS vnic:DynamicIdUniverse:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.5.1.5 |
cucsVnicDynamicIdUniverseNameCisco UCS vnic:DynamicIdUniverse:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.5.1.6 |
cucsVnicDynamicIdUniversePolicyLevelCisco UCS vnic:DynamicIdUniverse:policyLevel managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.5.1.7 |
cucsVnicDynamicIdUniversePolicyOwnerCisco UCS vnic:DynamicIdUniverse:policyOwner managed
object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.5.1.8 |
cucsVnicDynamicProviderTableCisco UCS vnic:DynamicProvider managed object table SEQUENCE OF CucsVnicDynamicProviderEntry .1.3.6.1.4.1.9.9.719.1.53.6 |
cucsVnicDynamicProviderEntryEntry for the cucsVnicDynamicProviderTable table. CucsVnicDynamicProviderEntry .1.3.6.1.4.1.9.9.719.1.53.6.1 |
cucsVnicDynamicProviderInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.6.1.1 |
cucsVnicDynamicProviderDnCisco UCS vnic:DynamicProvider:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.6.1.2 |
cucsVnicDynamicProviderRnCisco UCS vnic:DynamicProvider:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.6.1.3 |
cucsVnicDynamicProviderNameCisco UCS vnic:DynamicProvider:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.6.1.4 |
cucsVnicDynamicProviderEpTableCisco UCS vnic:DynamicProviderEp managed object table SEQUENCE OF CucsVnicDynamicProviderEpEntry .1.3.6.1.4.1.9.9.719.1.53.7 |
cucsVnicDynamicProviderEpEntryEntry for the cucsVnicDynamicProviderEpTable table. CucsVnicDynamicProviderEpEntry .1.3.6.1.4.1.9.9.719.1.53.7.1 |
cucsVnicDynamicProviderEpInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.7.1.1 |
cucsVnicDynamicProviderEpDnCisco UCS vnic:DynamicProviderEp:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.7.1.2 |
cucsVnicDynamicProviderEpRnCisco UCS vnic:DynamicProviderEp:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.7.1.3 |
cucsVnicDynamicProviderEpChassisIdCisco UCS vnic:DynamicProviderEp:chassisId managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.7.1.4 |
cucsVnicDynamicProviderEpPortIdCisco UCS vnic:DynamicProviderEp:portId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.7.1.5 |
cucsVnicDynamicProviderEpSlotIdCisco UCS vnic:DynamicProviderEp:slotId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.7.1.6 |
cucsVnicDynamicProviderEpSwitchIdCisco UCS vnic:DynamicProviderEp:switchId managed
object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.7.1.7 |
cucsVnicEthLifTableCisco UCS vnic:EthLif managed object table SEQUENCE OF CucsVnicEthLifEntry .1.3.6.1.4.1.9.9.719.1.53.8 |
cucsVnicEthLifEntryEntry for the cucsVnicEthLifTable table. CucsVnicEthLifEntry .1.3.6.1.4.1.9.9.719.1.53.8.1 |
cucsVnicEthLifInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.8.1.1 |
cucsVnicEthLifDnCisco UCS vnic:EthLif:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.8.1.2 |
cucsVnicEthLifRnCisco UCS vnic:EthLif:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.8.1.3 |
cucsVnicEthLifAddrCisco UCS vnic:EthLif:addr managed object propertyro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.8.1.4 |
cucsVnicEthLifNameCisco UCS vnic:EthLif:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.8.1.5 |
cucsVnicEthLifNicDnCisco UCS vnic:EthLif:nicDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.8.1.6 |
cucsVnicEthLifOwnerCisco UCS vnic:EthLif:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.8.1.7 |
cucsVnicEthLifSwitchIdCisco UCS vnic:EthLif:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.8.1.8 |
cucsVnicEthLifTypeCisco UCS vnic:EthLif:type managed object propertyro CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.8.1.9 |
cucsVnicEthLifVnicDnCisco UCS vnic:EthLif:vnicDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.8.1.10 |
cucsVnicEtherTableCisco UCS vnic:Ether managed object table SEQUENCE OF CucsVnicEtherEntry .1.3.6.1.4.1.9.9.719.1.53.9 |
cucsVnicEtherEntryEntry for the cucsVnicEtherTable table. CucsVnicEtherEntry .1.3.6.1.4.1.9.9.719.1.53.9.1 |
cucsVnicEtherInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.1 |
cucsVnicEtherDnCisco UCS vnic:Ether:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.2 |
cucsVnicEtherRnCisco UCS vnic:Ether:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.3 |
cucsVnicEtherAdaptorProfileNameCisco UCS vnic:Ether:adaptorProfileName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.4 |
cucsVnicEtherAddrCisco UCS vnic:Ether:addr managed object propertyro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.9.1.5 |
cucsVnicEtherAdminVconCisco UCS vnic:Ether:adminVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.6 |
cucsVnicEtherBootDevCisco UCS vnic:Ether:bootDev managed object propertyro CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.7 |
cucsVnicEtherConfigStateCisco UCS vnic:Ether:configState managed object propertyro CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.8 |
cucsVnicEtherEquipmentDnCisco UCS vnic:Ether:equipmentDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.9 |
cucsVnicEtherFltAggrCisco UCS vnic:Ether:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.9.1.10 |
cucsVnicEtherIdentPoolNameCisco UCS vnic:Ether:identPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.11 |
cucsVnicEtherInstTypeCisco UCS vnic:Ether:instType managed object propertyro CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.12 |
cucsVnicEtherMtuCisco UCS vnic:Ether:mtu managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.9.1.13 |
cucsVnicEtherNameCisco UCS vnic:Ether:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.14 |
cucsVnicEtherNwCtrlPolicyNameCisco UCS vnic:Ether:nwCtrlPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.15 |
cucsVnicEtherNwTemplNameCisco UCS vnic:Ether:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.16 |
cucsVnicEtherOperAdaptorProfileNameCisco UCS vnic:Ether:operAdaptorProfileName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.17 |
cucsVnicEtherOperIdentPoolNameCisco UCS vnic:Ether:operIdentPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.18 |
cucsVnicEtherOperNwCtrlPolicyNameCisco UCS vnic:Ether:operNwCtrlPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.19 |
cucsVnicEtherOperNwTemplNameCisco UCS vnic:Ether:operNwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.20 |
cucsVnicEtherOperOrderCisco UCS vnic:Ether:operOrder managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.9.1.21 |
cucsVnicEtherOperQosPolicyNameCisco UCS vnic:Ether:operQosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.22 |
cucsVnicEtherOperSpeedCisco UCS vnic:Ether:operSpeed managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.9.1.23 |
cucsVnicEtherOperStatsPolicyNameCisco UCS vnic:Ether:operStatsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.24 |
cucsVnicEtherOperVconCisco UCS vnic:Ether:operVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.25 |
cucsVnicEtherOrderCisco UCS vnic:Ether:order managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.9.1.26 |
cucsVnicEtherOwnerCisco UCS vnic:Ether:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.27 |
cucsVnicEtherPinToGroupNameCisco UCS vnic:Ether:pinToGroupName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.28 |
cucsVnicEtherQosPolicyNameCisco UCS vnic:Ether:qosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.29 |
cucsVnicEtherStatsPolicyNameCisco UCS vnic:Ether:statsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.30 |
cucsVnicEtherSwitchIdCisco UCS vnic:Ether:switchId managed object propertyro CucsVnicEtherBaseSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.31 |
cucsVnicEtherTypeCisco UCS vnic:Ether:type managed object propertyro CucsVnicEtherType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.32 |
cucsVnicEtherOperPinToGroupNameCisco UCS vnic:Ether:operPinToGroupName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.33 |
cucsVnicEtherConfigQualifierCisco UCS vnic:Ether:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.34 |
cucsVnicEtherDynamicIdCisco UCS vnic:Ether:dynamicId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.9.1.35 |
cucsVnicEtherPfDnCisco UCS vnic:Ether:pfDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.36 |
cucsVnicEtherVirtualizationPreferenceCisco UCS vnic:Ether:virtualizationPreference
managed object propertyro CucsVnicVirtualizationPreferenceType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.37 |
cucsVnicEtherAdminHostPortCisco UCS vnic:Ether:adminHostPort managed object propertyro CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.39 |
cucsVnicEtherOperHostPortCisco UCS vnic:Ether:operHostPort managed object propertyro CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.40 |
cucsVnicEtherPropAclCisco UCS vnic:Ether:propAcl managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.9.1.41 |
cucsVnicEtherPurposeCisco UCS vnic:Ether:purpose managed object propertyro CucsAdaptorPurpose (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.42 |
cucsVnicEtherAdminCdnNameCisco UCS vnic:Ether:adminCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.43 |
cucsVnicEtherOperCdnNameCisco UCS vnic:Ether:operCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.44 |
cucsVnicEtherCdnSourceCisco UCS vnic:Ether:cdnSource managed object propertyro CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.45 |
cucsVnicEtherCdnPropInSyncCisco UCS vnic:Ether:cdnPropInSync managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.9.1.46 |
cucsVnicEtherRedundancyPairTypeCisco UCS vnic:Ether:redundancyPairType managed object propertyro CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.47 |
cucsVnicEtherRedundancyPeerCisco UCS vnic:Ether:redundancyPeer managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.9.1.48 |
cucsVnicEtherIfTableCisco UCS vnic:EtherIf managed object table SEQUENCE OF CucsVnicEtherIfEntry .1.3.6.1.4.1.9.9.719.1.53.10 |
cucsVnicEtherIfEntryEntry for the cucsVnicEtherIfTable table. CucsVnicEtherIfEntry .1.3.6.1.4.1.9.9.719.1.53.10.1 |
cucsVnicEtherIfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.1 |
cucsVnicEtherIfDnCisco UCS vnic:EtherIf:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.2 |
cucsVnicEtherIfRnCisco UCS vnic:EtherIf:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.3 |
cucsVnicEtherIfAddrCisco UCS vnic:EtherIf:addr managed object propertyro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.10.1.4 |
cucsVnicEtherIfDefaultNetCisco UCS vnic:EtherIf:defaultNet managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.10.1.5 |
cucsVnicEtherIfNameCisco UCS vnic:EtherIf:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.6 |
cucsVnicEtherIfOperStateCisco UCS vnic:EtherIf:operState managed object propertyro CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.7 |
cucsVnicEtherIfOwnerCisco UCS vnic:EtherIf:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.8 |
cucsVnicEtherIfSwitchIdCisco UCS vnic:EtherIf:switchId managed object propertyro CucsVnicEtherBaseIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.9 |
cucsVnicEtherIfTypeCisco UCS vnic:EtherIf:type managed object propertyro CucsVnicAEtherIfType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.10 |
cucsVnicEtherIfVnetCisco UCS vnic:EtherIf:vnet managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.10.1.11 |
cucsVnicEtherIfOperVnetDnCisco UCS vnic:EtherIf:operVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.12 |
cucsVnicEtherIfOperVnetNameCisco UCS vnic:EtherIf:operVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.13 |
cucsVnicEtherIfConfigQualifierCisco UCS vnic:EtherIf:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.14 |
cucsVnicEtherIfFltAggrCisco UCS vnic:EtherIf:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.10.1.15 |
cucsVnicEtherIfPubNwIdCisco UCS vnic:EtherIf:pubNwId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.10.1.17 |
cucsVnicEtherIfSharingCisco UCS vnic:EtherIf:sharing managed object propertyro CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.18 |
cucsVnicEtherIfPropAclCisco UCS vnic:EtherIf:propAcl managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.10.1.19 |
cucsVnicEtherIfOperPrimaryVnetDnCisco UCS vnic:EtherIf:operPrimaryVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.20 |
cucsVnicEtherIfOperPrimaryVnetNameCisco UCS vnic:EtherIf:operPrimaryVnetName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.10.1.21 |
cucsVnicFcTableCisco UCS vnic:Fc managed object table SEQUENCE OF CucsVnicFcEntry .1.3.6.1.4.1.9.9.719.1.53.11 |
cucsVnicFcEntryEntry for the cucsVnicFcTable table. CucsVnicFcEntry .1.3.6.1.4.1.9.9.719.1.53.11.1 |
cucsVnicFcInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.1 |
cucsVnicFcDnCisco UCS vnic:Fc:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.2 |
cucsVnicFcRnCisco UCS vnic:Fc:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.3 |
cucsVnicFcAdaptorProfileNameCisco UCS vnic:Fc:adaptorProfileName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.4 |
cucsVnicFcAddrCisco UCS vnic:Fc:addr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.11.1.5 |
cucsVnicFcAdminVconCisco UCS vnic:Fc:adminVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.6 |
cucsVnicFcBootDevCisco UCS vnic:Fc:bootDev managed object propertyro CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.7 |
cucsVnicFcConfigStateCisco UCS vnic:Fc:configState managed object propertyro CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.8 |
cucsVnicFcEquipmentDnCisco UCS vnic:Fc:equipmentDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.9 |
cucsVnicFcFltAggrCisco UCS vnic:Fc:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.11.1.10 |
cucsVnicFcIdentPoolNameCisco UCS vnic:Fc:identPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.11 |
cucsVnicFcInstTypeCisco UCS vnic:Fc:instType managed object propertyro CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.12 |
cucsVnicFcMaxDataFieldSizeCisco UCS vnic:Fc:maxDataFieldSize managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.11.1.13 |
cucsVnicFcNameCisco UCS vnic:Fc:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.14 |
cucsVnicFcNdAddrCisco UCS vnic:Fc:nodeAddr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.11.1.15 |
cucsVnicFcNwTemplNameCisco UCS vnic:Fc:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.16 |
cucsVnicFcOperAdaptorProfileNameCisco UCS vnic:Fc:operAdaptorProfileName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.17 |
cucsVnicFcOperIdentPoolNameCisco UCS vnic:Fc:operIdentPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.18 |
cucsVnicFcOperNwTemplNameCisco UCS vnic:Fc:operNwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.19 |
cucsVnicFcOperOrderCisco UCS vnic:Fc:operOrder managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.11.1.20 |
cucsVnicFcOperQosPolicyNameCisco UCS vnic:Fc:operQosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.21 |
cucsVnicFcOperSpeedCisco UCS vnic:Fc:operSpeed managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.11.1.22 |
cucsVnicFcOperStatsPolicyNameCisco UCS vnic:Fc:operStatsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.23 |
cucsVnicFcOperVconCisco UCS vnic:Fc:operVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.24 |
cucsVnicFcOrderCisco UCS vnic:Fc:order managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.11.1.25 |
cucsVnicFcOwnerCisco UCS vnic:Fc:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.26 |
cucsVnicFcPersBindCisco UCS vnic:Fc:persBind managed object propertyro CucsVnicFcBasePersBind (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.27 |
cucsVnicFcPersBindClearCisco UCS vnic:Fc:persBindClear managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.11.1.28 |
cucsVnicFcPinToGroupNameCisco UCS vnic:Fc:pinToGroupName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.29 |
cucsVnicFcQosPolicyNameCisco UCS vnic:Fc:qosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.30 |
cucsVnicFcStatsPolicyNameCisco UCS vnic:Fc:statsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.31 |
cucsVnicFcSwitchIdCisco UCS vnic:Fc:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.32 |
cucsVnicFcTypeCisco UCS vnic:Fc:type managed object propertyro CucsVnicFcBaseType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.33 |
cucsVnicFcOperPinToGroupNameCisco UCS vnic:Fc:operPinToGroupName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.34 |
cucsVnicFcConfigQualifierCisco UCS vnic:Fc:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.35 |
cucsVnicFcAdminHostPortCisco UCS vnic:Fc:adminHostPort managed object propertyro CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.37 |
cucsVnicFcOperHostPortCisco UCS vnic:Fc:operHostPort managed object propertyro CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.38 |
cucsVnicFcAdminCdnNameCisco UCS vnic:Fc:adminCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.39 |
cucsVnicFcOperCdnNameCisco UCS vnic:Fc:operCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.40 |
cucsVnicFcCdnSourceCisco UCS vnic:Fc:cdnSource managed object propertyro CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.41 |
cucsVnicFcCdnPropInSyncCisco UCS vnic:Fc:cdnPropInSync managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.11.1.42 |
cucsVnicFcRedundancyPairTypeCisco UCS vnic:Fc:redundancyPairType managed object propertyro CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.43 |
cucsVnicFcRedundancyPeerCisco UCS vnic:Fc:redundancyPeer managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.11.1.44 |
cucsVnicFcIfTableCisco UCS vnic:FcIf managed object table SEQUENCE OF CucsVnicFcIfEntry .1.3.6.1.4.1.9.9.719.1.53.12 |
cucsVnicFcIfEntryEntry for the cucsVnicFcIfTable table. CucsVnicFcIfEntry .1.3.6.1.4.1.9.9.719.1.53.12.1 |
cucsVnicFcIfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.1 |
cucsVnicFcIfDnCisco UCS vnic:FcIf:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.2 |
cucsVnicFcIfRnCisco UCS vnic:FcIf:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.3 |
cucsVnicFcIfInitiatorCisco UCS vnic:FcIf:initiator managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.12.1.4 |
cucsVnicFcIfNameCisco UCS vnic:FcIf:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.5 |
cucsVnicFcIfOperStateCisco UCS vnic:FcIf:operState managed object propertyro CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.6 |
cucsVnicFcIfOwnerCisco UCS vnic:FcIf:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.7 |
cucsVnicFcIfSwitchIdCisco UCS vnic:FcIf:switchId managed object propertyro CucsVnicAFcIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.8 |
cucsVnicFcIfTypeCisco UCS vnic:FcIf:type managed object propertyro CucsVnicAFcIfType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.9 |
cucsVnicFcIfVnetCisco UCS vnic:FcIf:vnet managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.12.1.10 |
cucsVnicFcIfOperVnetDnCisco UCS vnic:FcIf:operVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.11 |
cucsVnicFcIfOperVnetNameCisco UCS vnic:FcIf:operVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.12 |
cucsVnicFcIfConfigQualifierCisco UCS vnic:FcIf:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.13 |
cucsVnicFcIfPubNwIdCisco UCS vnic:FcIf:pubNwId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.12.1.15 |
cucsVnicFcIfSharingCisco UCS vnic:FcIf:sharing managed object propertyro CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.16 |
cucsVnicFcIfOperPrimaryVnetDnCisco UCS vnic:FcIf:operPrimaryVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.17 |
cucsVnicFcIfOperPrimaryVnetNameCisco UCS vnic:FcIf:operPrimaryVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.12.1.18 |
cucsVnicFcLifTableCisco UCS vnic:FcLif managed object table SEQUENCE OF CucsVnicFcLifEntry .1.3.6.1.4.1.9.9.719.1.53.13 |
cucsVnicFcLifEntryEntry for the cucsVnicFcLifTable table. CucsVnicFcLifEntry .1.3.6.1.4.1.9.9.719.1.53.13.1 |
cucsVnicFcLifInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.13.1.1 |
cucsVnicFcLifDnCisco UCS vnic:FcLif:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.13.1.2 |
cucsVnicFcLifRnCisco UCS vnic:FcLif:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.13.1.3 |
cucsVnicFcLifAddrCisco UCS vnic:FcLif:addr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.13.1.4 |
cucsVnicFcLifNameCisco UCS vnic:FcLif:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.13.1.5 |
cucsVnicFcLifNicDnCisco UCS vnic:FcLif:nicDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.13.1.6 |
cucsVnicFcLifOwnerCisco UCS vnic:FcLif:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.13.1.7 |
cucsVnicFcLifSwitchIdCisco UCS vnic:FcLif:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.13.1.8 |
cucsVnicFcLifTypeCisco UCS vnic:FcLif:type managed object propertyro CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.13.1.9 |
cucsVnicFcLifVnicDnCisco UCS vnic:FcLif:vnicDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.13.1.10 |
cucsVnicFcNodeTableCisco UCS vnic:FcNode managed object table SEQUENCE OF CucsVnicFcNodeEntry .1.3.6.1.4.1.9.9.719.1.53.14 |
cucsVnicFcNodeEntryEntry for the cucsVnicFcNodeTable table. CucsVnicFcNodeEntry .1.3.6.1.4.1.9.9.719.1.53.14.1 |
cucsVnicFcNodeInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.14.1.1 |
cucsVnicFcNodeDnCisco UCS vnic:FcNode:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.14.1.2 |
cucsVnicFcNodeRnCisco UCS vnic:FcNode:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.14.1.3 |
cucsVnicFcNodeAddrCisco UCS vnic:FcNode:addr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.14.1.4 |
cucsVnicFcNodeFltAggrCisco UCS vnic:FcNode:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.14.1.5 |
cucsVnicFcNodeIdentPoolNameCisco UCS vnic:FcNode:identPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.14.1.6 |
cucsVnicFcNodeOperIdentPoolNameCisco UCS vnic:FcNode:operIdentPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.14.1.7 |
cucsVnicFcNodeMaxDerivableWWPNCisco UCS vnic:FcNode:maxDerivableWWPN managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.14.1.8 |
cucsVnicFcNodeOwnerCisco UCS vnic:FcNode:owner managed object propertyro CucsVnicFcNodeOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.14.1.9 |
cucsVnicFcOEIfTableCisco UCS vnic:FcOEIf managed object table SEQUENCE OF CucsVnicFcOEIfEntry .1.3.6.1.4.1.9.9.719.1.53.15 |
cucsVnicFcOEIfEntryEntry for the cucsVnicFcOEIfTable table. CucsVnicFcOEIfEntry .1.3.6.1.4.1.9.9.719.1.53.15.1 |
cucsVnicFcOEIfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.1 |
cucsVnicFcOEIfDnCisco UCS vnic:FcOEIf:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.2 |
cucsVnicFcOEIfRnCisco UCS vnic:FcOEIf:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.3 |
cucsVnicFcOEIfInitiatorCisco UCS vnic:FcOEIf:initiator managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.15.1.4 |
cucsVnicFcOEIfNameCisco UCS vnic:FcOEIf:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.5 |
cucsVnicFcOEIfOperStateCisco UCS vnic:FcOEIf:operState managed object propertyro CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.6 |
cucsVnicFcOEIfOwnerCisco UCS vnic:FcOEIf:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.7 |
cucsVnicFcOEIfSwitchIdCisco UCS vnic:FcOEIf:switchId managed object propertyro CucsVnicAFcIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.8 |
cucsVnicFcOEIfTypeCisco UCS vnic:FcOEIf:type managed object propertyro CucsVnicAFcIfType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.9 |
cucsVnicFcOEIfVnetCisco UCS vnic:FcOEIf:vnet managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.15.1.10 |
cucsVnicFcOEIfConfigQualifierCisco UCS vnic:FcOEIf:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.11 |
cucsVnicFcOEIfOperVnetDnCisco UCS vnic:FcOEIf:operVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.13 |
cucsVnicFcOEIfOperVnetNameCisco UCS vnic:FcOEIf:operVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.14 |
cucsVnicFcOEIfPubNwIdCisco UCS vnic:FcOEIf:pubNwId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.15.1.15 |
cucsVnicFcOEIfSharingCisco UCS vnic:FcOEIf:sharing managed object propertyro CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.16 |
cucsVnicFcOEIfOperPrimaryVnetDnCisco UCS vnic:FcOEIf:operPrimaryVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.17 |
cucsVnicFcOEIfOperPrimaryVnetNameCisco UCS vnic:FcOEIf:operPrimaryVnetName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.15.1.18 |
cucsVnicIPv4DhcpTableCisco UCS vnic:IPv4Dhcp managed object table SEQUENCE OF CucsVnicIPv4DhcpEntry .1.3.6.1.4.1.9.9.719.1.53.16 |
cucsVnicIPv4DhcpEntryEntry for the cucsVnicIPv4DhcpTable table. CucsVnicIPv4DhcpEntry .1.3.6.1.4.1.9.9.719.1.53.16.1 |
cucsVnicIPv4DhcpInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.16.1.1 |
cucsVnicIPv4DhcpDnCisco UCS vnic:IPv4Dhcp:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.16.1.2 |
cucsVnicIPv4DhcpRnCisco UCS vnic:IPv4Dhcp:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.16.1.3 |
cucsVnicIPv4DhcpAddrCisco UCS vnic:IPv4Dhcp:addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.16.1.4 |
cucsVnicIPv4DhcpDefGwCisco UCS vnic:IPv4Dhcp:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.16.1.5 |
cucsVnicIPv4DhcpSubnetCisco UCS vnic:IPv4Dhcp:subnet managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.16.1.6 |
cucsVnicIPv4DnsTableCisco UCS vnic:IPv4Dns managed object table SEQUENCE OF CucsVnicIPv4DnsEntry .1.3.6.1.4.1.9.9.719.1.53.17 |
cucsVnicIPv4DnsEntryEntry for the cucsVnicIPv4DnsTable table. CucsVnicIPv4DnsEntry .1.3.6.1.4.1.9.9.719.1.53.17.1 |
cucsVnicIPv4DnsInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.17.1.1 |
cucsVnicIPv4DnsDnCisco UCS vnic:IPv4Dns:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.17.1.2 |
cucsVnicIPv4DnsRnCisco UCS vnic:IPv4Dns:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.17.1.3 |
cucsVnicIPv4DnsAddrCisco UCS vnic:IPv4Dns:addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.17.1.4 |
cucsVnicIPv4DnsDefGwCisco UCS vnic:IPv4Dns:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.17.1.5 |
cucsVnicIPv4DnsPrefCisco UCS vnic:IPv4Dns:pref managed object propertyro CucsVnicIPv4DnsPref (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.17.1.6 |
cucsVnicIPv4DnsSubnetCisco UCS vnic:IPv4Dns:subnet managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.17.1.7 |
cucsVnicIPv4IfTableCisco UCS vnic:IPv4If managed object table SEQUENCE OF CucsVnicIPv4IfEntry .1.3.6.1.4.1.9.9.719.1.53.18 |
cucsVnicIPv4IfEntryEntry for the cucsVnicIPv4IfTable table. CucsVnicIPv4IfEntry .1.3.6.1.4.1.9.9.719.1.53.18.1 |
cucsVnicIPv4IfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.1 |
cucsVnicIPv4IfDnCisco UCS vnic:IPv4If:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.2 |
cucsVnicIPv4IfRnCisco UCS vnic:IPv4If:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.3 |
cucsVnicIPv4IfAddrCisco UCS vnic:IPv4If:addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.4 |
cucsVnicIPv4IfNameCisco UCS vnic:IPv4If:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.5 |
cucsVnicIPv4IfOperStateCisco UCS vnic:IPv4If:operState managed object propertyro CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.6 |
cucsVnicIPv4IfOwnerCisco UCS vnic:IPv4If:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.7 |
cucsVnicIPv4IfSwitchIdCisco UCS vnic:IPv4If:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.8 |
cucsVnicIPv4IfTypeCisco UCS vnic:IPv4If:type managed object propertyro CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.9 |
cucsVnicIPv4IfVnetCisco UCS vnic:IPv4If:vnet managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.18.1.10 |
cucsVnicIPv4IfConfigQualifierCisco UCS vnic:IPv4If:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.11 |
cucsVnicIPv4IfOperVnetDnCisco UCS vnic:IPv4If:operVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.13 |
cucsVnicIPv4IfOperVnetNameCisco UCS vnic:IPv4If:operVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.14 |
cucsVnicIPv4IfPubNwIdCisco UCS vnic:IPv4If:pubNwId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.18.1.15 |
cucsVnicIPv4IfSharingCisco UCS vnic:IPv4If:sharing managed object propertyro CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.16 |
cucsVnicIPv4IfPropAclCisco UCS vnic:IPv4If:propAcl managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.18.1.17 |
cucsVnicIPv4IfOperPrimaryVnetDnCisco UCS vnic:IPv4If:operPrimaryVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.18 |
cucsVnicIPv4IfOperPrimaryVnetNameCisco UCS vnic:IPv4If:operPrimaryVnetName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.18.1.19 |
cucsVnicIPv4StaticRouteTableCisco UCS vnic:IPv4StaticRoute managed object table SEQUENCE OF CucsVnicIPv4StaticRouteEntry .1.3.6.1.4.1.9.9.719.1.53.19 |
cucsVnicIPv4StaticRouteEntryEntry for the cucsVnicIPv4StaticRouteTable table. CucsVnicIPv4StaticRouteEntry .1.3.6.1.4.1.9.9.719.1.53.19.1 |
cucsVnicIPv4StaticRouteInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.19.1.1 |
cucsVnicIPv4StaticRouteDnCisco UCS vnic:IPv4StaticRoute:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.19.1.2 |
cucsVnicIPv4StaticRouteRnCisco UCS vnic:IPv4StaticRoute:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.19.1.3 |
cucsVnicIPv4StaticRouteAddrCisco UCS vnic:IPv4StaticRoute:addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.19.1.4 |
cucsVnicIPv4StaticRouteDefGwCisco UCS vnic:IPv4StaticRoute:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.19.1.5 |
cucsVnicIPv4StaticRouteGwAddrCisco UCS vnic:IPv4StaticRoute:gwAddr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.19.1.6 |
cucsVnicIPv4StaticRouteGwSubnetCisco UCS vnic:IPv4StaticRoute:gwSubnet managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.19.1.7 |
cucsVnicIPv4StaticRouteSubnetCisco UCS vnic:IPv4StaticRoute:subnet managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.19.1.8 |
cucsVnicIpV4PooledAddrTableCisco UCS vnic:IpV4PooledAddr managed object table SEQUENCE OF CucsVnicIpV4PooledAddrEntry .1.3.6.1.4.1.9.9.719.1.53.20 |
cucsVnicIpV4PooledAddrEntryEntry for the cucsVnicIpV4PooledAddrTable table. CucsVnicIpV4PooledAddrEntry .1.3.6.1.4.1.9.9.719.1.53.20.1 |
cucsVnicIpV4PooledAddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.20.1.1 |
cucsVnicIpV4PooledAddrDnCisco UCS vnic:IpV4PooledAddr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.20.1.2 |
cucsVnicIpV4PooledAddrRnCisco UCS vnic:IpV4PooledAddr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.20.1.3 |
cucsVnicIpV4PooledAddrAddrCisco UCS vnic:IpV4PooledAddr:addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.20.1.4 |
cucsVnicIpV4PooledAddrDefGwCisco UCS vnic:IpV4PooledAddr:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.20.1.5 |
cucsVnicIpV4PooledAddrNameCisco UCS vnic:IpV4PooledAddr:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.20.1.6 |
cucsVnicIpV4PooledAddrSubnetCisco UCS vnic:IpV4PooledAddr:subnet managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.20.1.7 |
cucsVnicIpV4PooledAddrOperNameCisco UCS vnic:IpV4PooledAddr:operName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.20.1.8 |
cucsVnicIpV4PooledAddrPrimDnsCisco UCS vnic:IpV4PooledAddr:primDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.20.1.9 |
cucsVnicIpV4PooledAddrSecDnsCisco UCS vnic:IpV4PooledAddr:secDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.20.1.10 |
cucsVnicIpV4ProfDerivedAddrTableCisco UCS vnic:IpV4ProfDerivedAddr managed object table SEQUENCE OF CucsVnicIpV4ProfDerivedAddrEntry .1.3.6.1.4.1.9.9.719.1.53.21 |
cucsVnicIpV4ProfDerivedAddrEntryEntry for the cucsVnicIpV4ProfDerivedAddrTable table. CucsVnicIpV4ProfDerivedAddrEntry .1.3.6.1.4.1.9.9.719.1.53.21.1 |
cucsVnicIpV4ProfDerivedAddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.21.1.1 |
cucsVnicIpV4ProfDerivedAddrDnCisco UCS vnic:IpV4ProfDerivedAddr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.21.1.2 |
cucsVnicIpV4ProfDerivedAddrRnCisco UCS vnic:IpV4ProfDerivedAddr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.21.1.3 |
cucsVnicIpV4ProfDerivedAddrAddrCisco UCS vnic:IpV4ProfDerivedAddr:addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.21.1.4 |
cucsVnicIpV4ProfDerivedAddrDefGwCisco UCS vnic:IpV4ProfDerivedAddr:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.21.1.5 |
cucsVnicIpV4ProfDerivedAddrSubnetCisco UCS vnic:IpV4ProfDerivedAddr:subnet managed
object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.21.1.6 |
cucsVnicIpV4StaticAddrTableCisco UCS vnic:IpV4StaticAddr managed object table SEQUENCE OF CucsVnicIpV4StaticAddrEntry .1.3.6.1.4.1.9.9.719.1.53.22 |
cucsVnicIpV4StaticAddrEntryEntry for the cucsVnicIpV4StaticAddrTable table. CucsVnicIpV4StaticAddrEntry .1.3.6.1.4.1.9.9.719.1.53.22.1 |
cucsVnicIpV4StaticAddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.22.1.1 |
cucsVnicIpV4StaticAddrDnCisco UCS vnic:IpV4StaticAddr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.22.1.2 |
cucsVnicIpV4StaticAddrRnCisco UCS vnic:IpV4StaticAddr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.22.1.3 |
cucsVnicIpV4StaticAddrAddrCisco UCS vnic:IpV4StaticAddr:addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.22.1.4 |
cucsVnicIpV4StaticAddrDefGwCisco UCS vnic:IpV4StaticAddr:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.22.1.5 |
cucsVnicIpV4StaticAddrSubnetCisco UCS vnic:IpV4StaticAddr:subnet managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.22.1.6 |
cucsVnicIpV4StaticAddrPrimDnsCisco UCS vnic:IpV4StaticAddr:primDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.22.1.7 |
cucsVnicIpV4StaticAddrSecDnsCisco UCS vnic:IpV4StaticAddr:secDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.22.1.8 |
cucsVnicIpcTableCisco UCS vnic:Ipc managed object table SEQUENCE OF CucsVnicIpcEntry .1.3.6.1.4.1.9.9.719.1.53.23 |
cucsVnicIpcEntryEntry for the cucsVnicIpcTable table. CucsVnicIpcEntry .1.3.6.1.4.1.9.9.719.1.53.23.1 |
cucsVnicIpcInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.1 |
cucsVnicIpcDnCisco UCS vnic:Ipc:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.2 |
cucsVnicIpcRnCisco UCS vnic:Ipc:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.3 |
cucsVnicIpcAdaptorProfileNameCisco UCS vnic:Ipc:adaptorProfileName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.4 |
cucsVnicIpcAddrCisco UCS vnic:Ipc:addr managed object propertyro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.23.1.5 |
cucsVnicIpcAdminVconCisco UCS vnic:Ipc:adminVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.6 |
cucsVnicIpcBootDevCisco UCS vnic:Ipc:bootDev managed object propertyro CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.7 |
cucsVnicIpcConfigStateCisco UCS vnic:Ipc:configState managed object propertyro CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.8 |
cucsVnicIpcEquipmentDnCisco UCS vnic:Ipc:equipmentDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.9 |
cucsVnicIpcIdentPoolNameCisco UCS vnic:Ipc:identPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.10 |
cucsVnicIpcInstTypeCisco UCS vnic:Ipc:instType managed object propertyro CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.11 |
cucsVnicIpcMtuCisco UCS vnic:Ipc:mtu managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.23.1.12 |
cucsVnicIpcNameCisco UCS vnic:Ipc:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.13 |
cucsVnicIpcNwCtrlPolicyNameCisco UCS vnic:Ipc:nwCtrlPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.14 |
cucsVnicIpcNwTemplNameCisco UCS vnic:Ipc:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.15 |
cucsVnicIpcOperAdaptorProfileNameCisco UCS vnic:Ipc:operAdaptorProfileName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.16 |
cucsVnicIpcOperIdentPoolNameCisco UCS vnic:Ipc:operIdentPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.17 |
cucsVnicIpcOperNwCtrlPolicyNameCisco UCS vnic:Ipc:operNwCtrlPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.18 |
cucsVnicIpcOperNwTemplNameCisco UCS vnic:Ipc:operNwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.19 |
cucsVnicIpcOperOrderCisco UCS vnic:Ipc:operOrder managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.23.1.20 |
cucsVnicIpcOperQosPolicyNameCisco UCS vnic:Ipc:operQosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.21 |
cucsVnicIpcOperSpeedCisco UCS vnic:Ipc:operSpeed managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.23.1.22 |
cucsVnicIpcOperStatsPolicyNameCisco UCS vnic:Ipc:operStatsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.23 |
cucsVnicIpcOperVconCisco UCS vnic:Ipc:operVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.24 |
cucsVnicIpcOrderCisco UCS vnic:Ipc:order managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.23.1.25 |
cucsVnicIpcOwnerCisco UCS vnic:Ipc:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.26 |
cucsVnicIpcPinToGroupNameCisco UCS vnic:Ipc:pinToGroupName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.27 |
cucsVnicIpcQosPolicyNameCisco UCS vnic:Ipc:qosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.28 |
cucsVnicIpcStatsPolicyNameCisco UCS vnic:Ipc:statsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.29 |
cucsVnicIpcSwitchIdCisco UCS vnic:Ipc:switchId managed object propertyro CucsVnicEtherBaseSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.30 |
cucsVnicIpcTypeCisco UCS vnic:Ipc:type managed object propertyro CucsVnicIpcType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.31 |
cucsVnicIpcOperPinToGroupNameCisco UCS vnic:Ipc:operPinToGroupName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.32 |
cucsVnicIpcConfigQualifierCisco UCS vnic:Ipc:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.33 |
cucsVnicIpcAdminHostPortCisco UCS vnic:Ipc:adminHostPort managed object propertyro CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.35 |
cucsVnicIpcOperHostPortCisco UCS vnic:Ipc:operHostPort managed object propertyro CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.36 |
cucsVnicIpcPurposeCisco UCS vnic:Ipc:purpose managed object propertyro CucsAdaptorPurpose (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.37 |
cucsVnicIpcAdminCdnNameCisco UCS vnic:Ipc:adminCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.38 |
cucsVnicIpcOperCdnNameCisco UCS vnic:Ipc:operCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.39 |
cucsVnicIpcCdnPropInSyncCisco UCS vnic:Ipc:cdnPropInSync managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.23.1.40 |
cucsVnicIpcCdnSourceCisco UCS vnic:Ipc:cdnSource managed object propertyro CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.41 |
cucsVnicIpcRedundancyPairTypeCisco UCS vnic:Ipc:redundancyPairType managed object propertyro CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.42 |
cucsVnicIpcRedundancyPeerCisco UCS vnic:Ipc:redundancyPeer managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.23.1.43 |
cucsVnicIpcIfTableCisco UCS vnic:IpcIf managed object table SEQUENCE OF CucsVnicIpcIfEntry .1.3.6.1.4.1.9.9.719.1.53.24 |
cucsVnicIpcIfEntryEntry for the cucsVnicIpcIfTable table. CucsVnicIpcIfEntry .1.3.6.1.4.1.9.9.719.1.53.24.1 |
cucsVnicIpcIfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.1 |
cucsVnicIpcIfDnCisco UCS vnic:IpcIf:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.2 |
cucsVnicIpcIfRnCisco UCS vnic:IpcIf:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.3 |
cucsVnicIpcIfAddrCisco UCS vnic:IpcIf:addr managed object propertyro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.24.1.4 |
cucsVnicIpcIfDefaultNetCisco UCS vnic:IpcIf:defaultNet managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.24.1.5 |
cucsVnicIpcIfNameCisco UCS vnic:IpcIf:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.6 |
cucsVnicIpcIfOperStateCisco UCS vnic:IpcIf:operState managed object propertyro CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.7 |
cucsVnicIpcIfOwnerCisco UCS vnic:IpcIf:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.8 |
cucsVnicIpcIfSwitchIdCisco UCS vnic:IpcIf:switchId managed object propertyro CucsVnicEtherBaseIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.9 |
cucsVnicIpcIfTypeCisco UCS vnic:IpcIf:type managed object propertyro CucsVnicAIpcIfType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.10 |
cucsVnicIpcIfVnetCisco UCS vnic:IpcIf:vnet managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.24.1.11 |
cucsVnicIpcIfConfigQualifierCisco UCS vnic:IpcIf:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.12 |
cucsVnicIpcIfOperVnetDnCisco UCS vnic:IpcIf:operVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.14 |
cucsVnicIpcIfOperVnetNameCisco UCS vnic:IpcIf:operVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.15 |
cucsVnicIpcIfPubNwIdCisco UCS vnic:IpcIf:pubNwId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.24.1.16 |
cucsVnicIpcIfSharingCisco UCS vnic:IpcIf:sharing managed object propertyro CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.17 |
cucsVnicIpcIfOperPrimaryVnetDnCisco UCS vnic:IpcIf:operPrimaryVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.18 |
cucsVnicIpcIfOperPrimaryVnetNameCisco UCS vnic:IpcIf:operPrimaryVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.24.1.19 |
cucsVnicLanConnTemplTableCisco UCS vnic:LanConnTempl managed object table SEQUENCE OF CucsVnicLanConnTemplEntry .1.3.6.1.4.1.9.9.719.1.53.25 |
cucsVnicLanConnTemplEntryEntry for the cucsVnicLanConnTemplTable table. CucsVnicLanConnTemplEntry .1.3.6.1.4.1.9.9.719.1.53.25.1 |
cucsVnicLanConnTemplInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.1 |
cucsVnicLanConnTemplDnCisco UCS vnic:LanConnTempl:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.2 |
cucsVnicLanConnTemplRnCisco UCS vnic:LanConnTempl:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.3 |
cucsVnicLanConnTemplDescrCisco UCS vnic:LanConnTempl:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.4 |
cucsVnicLanConnTemplIdentPoolNameCisco UCS vnic:LanConnTempl:identPoolName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.5 |
cucsVnicLanConnTemplIntIdCisco UCS vnic:LanConnTempl:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.6 |
cucsVnicLanConnTemplMtuCisco UCS vnic:LanConnTempl:mtu managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.25.1.7 |
cucsVnicLanConnTemplNameCisco UCS vnic:LanConnTempl:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.8 |
cucsVnicLanConnTemplNwCtrlPolicyNameCisco UCS vnic:LanConnTempl:nwCtrlPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.9 |
cucsVnicLanConnTemplOperIdentPoolNameCisco UCS vnic:LanConnTempl:operIdentPoolName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.10 |
cucsVnicLanConnTemplOperNwCtrlPolicyNameCisco UCS vnic:LanConnTempl:operNwCtrlPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.11 |
cucsVnicLanConnTemplOperQosPolicyNameCisco UCS vnic:LanConnTempl:operQosPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.12 |
cucsVnicLanConnTemplOperStatsPolicyNameCisco UCS vnic:LanConnTempl:operStatsPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.13 |
cucsVnicLanConnTemplPinToGroupNameCisco UCS vnic:LanConnTempl:pinToGroupName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.14 |
cucsVnicLanConnTemplQosPolicyNameCisco UCS vnic:LanConnTempl:qosPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.15 |
cucsVnicLanConnTemplStatsPolicyNameCisco UCS vnic:LanConnTempl:statsPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.16 |
cucsVnicLanConnTemplSwitchIdCisco UCS vnic:LanConnTempl:switchId managed object propertyro CucsVnicLanConnTemplSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.17 |
cucsVnicLanConnTemplTargetCisco UCS vnic:LanConnTempl:target managed object propertyro CucsVnicTemplateTarget (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.18 |
cucsVnicLanConnTemplTemplTypeCisco UCS vnic:LanConnTempl:templType managed object propertyro CucsVnicTemplateType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.19 |
cucsVnicLanConnTemplPolicyLevelCisco UCS vnic:LanConnTempl:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.25.1.20 |
cucsVnicLanConnTemplPolicyOwnerCisco UCS vnic:LanConnTempl:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.21 |
cucsVnicLanConnTemplAdminCdnNameCisco UCS vnic:LanConnTempl:adminCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.22 |
cucsVnicLanConnTemplCdnSourceCisco UCS vnic:LanConnTempl:cdnSource managed object propertyro CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.23 |
cucsVnicLanConnTemplOperPeerRedundancyTemplNameCisco UCS vnic:LanConnTempl:operPeerRedundancyTemplName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.24 |
cucsVnicLanConnTemplPeerRedundancyTemplNameCisco UCS vnic:LanConnTempl:peerRedundancyTemplName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.25 |
cucsVnicLanConnTemplRedundancyPairTypeCisco UCS vnic:LanConnTempl:redundancyPairType
managed object propertyro CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.25.1.26 |
cucsVnicLifVlanTableCisco UCS vnic:LifVlan managed object table SEQUENCE OF CucsVnicLifVlanEntry .1.3.6.1.4.1.9.9.719.1.53.26 |
cucsVnicLifVlanEntryEntry for the cucsVnicLifVlanTable table. CucsVnicLifVlanEntry .1.3.6.1.4.1.9.9.719.1.53.26.1 |
cucsVnicLifVlanInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.1 |
cucsVnicLifVlanDnCisco UCS vnic:LifVlan:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.2 |
cucsVnicLifVlanRnCisco UCS vnic:LifVlan:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.3 |
cucsVnicLifVlanAddrCisco UCS vnic:LifVlan:addr managed object propertyro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.26.1.4 |
cucsVnicLifVlanDefaultNetCisco UCS vnic:LifVlan:defaultNet managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.26.1.5 |
cucsVnicLifVlanNameCisco UCS vnic:LifVlan:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.6 |
cucsVnicLifVlanOperStateCisco UCS vnic:LifVlan:operState managed object propertyro CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.7 |
cucsVnicLifVlanOwnerCisco UCS vnic:LifVlan:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.8 |
cucsVnicLifVlanSwitchIdCisco UCS vnic:LifVlan:switchId managed object propertyro CucsVnicEtherBaseIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.9 |
cucsVnicLifVlanTypeCisco UCS vnic:LifVlan:type managed object propertyro CucsVnicAEtherIfType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.10 |
cucsVnicLifVlanVnetCisco UCS vnic:LifVlan:vnet managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.26.1.11 |
cucsVnicLifVlanConfigQualifierCisco UCS vnic:LifVlan:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.12 |
cucsVnicLifVlanOperVnetDnCisco UCS vnic:LifVlan:operVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.14 |
cucsVnicLifVlanOperVnetNameCisco UCS vnic:LifVlan:operVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.15 |
cucsVnicLifVlanPubNwIdCisco UCS vnic:LifVlan:pubNwId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.26.1.16 |
cucsVnicLifVlanSharingCisco UCS vnic:LifVlan:sharing managed object propertyro CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.17 |
cucsVnicLifVlanPropAclCisco UCS vnic:LifVlan:propAcl managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.26.1.18 |
cucsVnicLifVlanOperPrimaryVnetDnCisco UCS vnic:LifVlan:operPrimaryVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.19 |
cucsVnicLifVlanOperPrimaryVnetNameCisco UCS vnic:LifVlan:operPrimaryVnetName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.26.1.20 |
cucsVnicLifVsanTableCisco UCS vnic:LifVsan managed object table SEQUENCE OF CucsVnicLifVsanEntry .1.3.6.1.4.1.9.9.719.1.53.27 |
cucsVnicLifVsanEntryEntry for the cucsVnicLifVsanTable table. CucsVnicLifVsanEntry .1.3.6.1.4.1.9.9.719.1.53.27.1 |
cucsVnicLifVsanInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.1 |
cucsVnicLifVsanDnCisco UCS vnic:LifVsan:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.2 |
cucsVnicLifVsanRnCisco UCS vnic:LifVsan:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.3 |
cucsVnicLifVsanInitiatorCisco UCS vnic:LifVsan:initiator managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.27.1.4 |
cucsVnicLifVsanNameCisco UCS vnic:LifVsan:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.5 |
cucsVnicLifVsanOperStateCisco UCS vnic:LifVsan:operState managed object propertyro CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.6 |
cucsVnicLifVsanOwnerCisco UCS vnic:LifVsan:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.7 |
cucsVnicLifVsanSwitchIdCisco UCS vnic:LifVsan:switchId managed object propertyro CucsVnicAFcIfSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.8 |
cucsVnicLifVsanTypeCisco UCS vnic:LifVsan:type managed object propertyro CucsVnicAFcIfType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.9 |
cucsVnicLifVsanVnetCisco UCS vnic:LifVsan:vnet managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.27.1.10 |
cucsVnicLifVsanConfigQualifierCisco UCS vnic:LifVsan:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.11 |
cucsVnicLifVsanOperVnetDnCisco UCS vnic:LifVsan:operVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.13 |
cucsVnicLifVsanOperVnetNameCisco UCS vnic:LifVsan:operVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.14 |
cucsVnicLifVsanPubNwIdCisco UCS vnic:LifVsan:pubNwId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.27.1.15 |
cucsVnicLifVsanSharingCisco UCS vnic:LifVsan:sharing managed object propertyro CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.16 |
cucsVnicLifVsanOperPrimaryVnetDnCisco UCS vnic:LifVsan:operPrimaryVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.17 |
cucsVnicLifVsanOperPrimaryVnetNameCisco UCS vnic:LifVsan:operPrimaryVnetName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.27.1.18 |
cucsVnicProfileTableCisco UCS vnic:Profile managed object table SEQUENCE OF CucsVnicProfileEntry .1.3.6.1.4.1.9.9.719.1.53.28 |
cucsVnicProfileEntryEntry for the cucsVnicProfileTable table. CucsVnicProfileEntry .1.3.6.1.4.1.9.9.719.1.53.28.1 |
cucsVnicProfileInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.1 |
cucsVnicProfileDnCisco UCS vnic:Profile:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.2 |
cucsVnicProfileRnCisco UCS vnic:Profile:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.3 |
cucsVnicProfileCdpCisco UCS vnic:Profile:cdp managed object propertyro CucsNwctrlAdminState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.5 |
cucsVnicProfileCosCisco UCS vnic:Profile:cos managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.28.1.6 |
cucsVnicProfileDescrCisco UCS vnic:Profile:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.7 |
cucsVnicProfileForgeMacCisco UCS vnic:Profile:forgeMac managed object propertyro CucsDpsecForgedTransmit (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.8 |
cucsVnicProfileIntIdCisco UCS vnic:Profile:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.9 |
cucsVnicProfileMaxPortsCisco UCS vnic:Profile:maxPorts managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.28.1.10 |
cucsVnicProfileNameCisco UCS vnic:Profile:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.11 |
cucsVnicProfileNwCtrlPolicyNameCisco UCS vnic:Profile:nwCtrlPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.12 |
cucsVnicProfileOperNwCtrlPolicyNameCisco UCS vnic:Profile:operNwCtrlPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.13 |
cucsVnicProfileOperQosPolicyNameCisco UCS vnic:Profile:operQosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.14 |
cucsVnicProfilePinToGroupNameCisco UCS vnic:Profile:pinToGroupName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.15 |
cucsVnicProfileQosPolicyIdCisco UCS vnic:Profile:qosPolicyId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.16 |
cucsVnicProfileQosPolicyNameCisco UCS vnic:Profile:qosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.17 |
cucsVnicProfileSwABorderPortCisco UCS vnic:Profile:swABorderPort managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.28.1.19 |
cucsVnicProfileSwABorderSlotCisco UCS vnic:Profile:swABorderSlot managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.28.1.20 |
cucsVnicProfileSwBBorderPortCisco UCS vnic:Profile:swBBorderPort managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.28.1.21 |
cucsVnicProfileSwBBorderSlotCisco UCS vnic:Profile:swBBorderSlot managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.28.1.22 |
cucsVnicProfileUplinkFailActionCisco UCS vnic:Profile:uplinkFailAction managed object propertyro CucsNwctrlLinkFailAction (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.23 |
cucsVnicProfileHostNwIOPerfCisco UCS vnic:Profile:hostNwIOPerf managed object propertyro CucsVnicHostNwIOPerfPref (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.24 |
cucsVnicProfilePrimaryVlanIdCisco UCS vnic:Profile:primaryVlanId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.28.1.25 |
cucsVnicProfileQosPolicyDnCisco UCS vnic:Profile:qosPolicyDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.26 |
cucsVnicProfileConfigQualifierCisco UCS vnic:Profile:configQualifier managed object propertyro CucsVnicProfileConfigQualifier (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.27 |
cucsVnicProfileMacRegisterModeCisco UCS vnic:Profile:macRegisterMode managed object propertyro CucsNwctrlRegistrationMode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.28 |
cucsVnicProfilePolicyLevelCisco UCS vnic:Profile:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.28.1.29 |
cucsVnicProfilePolicyOwnerCisco UCS vnic:Profile:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.30 |
cucsVnicProfilePortProfileUuidCisco UCS vnic:Profile:portProfileUuid managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.31 |
cucsVnicProfileTypeCisco UCS vnic:Profile:type managed object propertyro CucsVnicPortProfileType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.32 |
cucsVnicProfileSwABorderAggrPortCisco UCS vnic:Profile:swABorderAggrPort managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.28.1.33 |
cucsVnicProfileSwBBorderAggrPortCisco UCS vnic:Profile:swBBorderAggrPort managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.28.1.34 |
cucsVnicProfileLldpCisco UCS vnic:Profile:lldp managed object propertyro CucsNwctrlLldpAdminStateBitmask (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.28.1.35 |
cucsVnicProfileAliasTableCisco UCS vnic:ProfileAlias managed object table SEQUENCE OF CucsVnicProfileAliasEntry .1.3.6.1.4.1.9.9.719.1.53.29 |
cucsVnicProfileAliasEntryEntry for the cucsVnicProfileAliasTable table. CucsVnicProfileAliasEntry .1.3.6.1.4.1.9.9.719.1.53.29.1 |
cucsVnicProfileAliasInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.29.1.1 |
cucsVnicProfileAliasDnCisco UCS vnic:ProfileAlias:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.29.1.2 |
cucsVnicProfileAliasRnCisco UCS vnic:ProfileAlias:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.29.1.3 |
cucsVnicProfileAliasAliasCisco UCS vnic:ProfileAlias:alias managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.29.1.4 |
cucsVnicProfileAliasSwUuidCisco UCS vnic:ProfileAlias:swUuid managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.29.1.5 |
cucsVnicProfileSetTableCisco UCS vnic:ProfileSet managed object table SEQUENCE OF CucsVnicProfileSetEntry .1.3.6.1.4.1.9.9.719.1.53.30 |
cucsVnicProfileSetEntryEntry for the cucsVnicProfileSetTable table. CucsVnicProfileSetEntry .1.3.6.1.4.1.9.9.719.1.53.30.1 |
cucsVnicProfileSetInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.30.1.1 |
cucsVnicProfileSetDnCisco UCS vnic:ProfileSet:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.30.1.2 |
cucsVnicProfileSetRnCisco UCS vnic:ProfileSet:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.30.1.3 |
cucsVnicProfileSetFsmDescrCisco UCS vnic:ProfileSet:fsmDescr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.30.1.4 |
cucsVnicProfileSetFsmPrevCisco UCS vnic:ProfileSet:fsmPrev managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.30.1.5 |
cucsVnicProfileSetFsmProgrCisco UCS vnic:ProfileSet:fsmProgr managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.30.1.6 |
cucsVnicProfileSetFsmRmtInvErrCodeCisco UCS vnic:ProfileSet:fsmRmtInvErrCode managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.30.1.7 |
cucsVnicProfileSetFsmRmtInvErrDescrCisco UCS vnic:ProfileSet:fsmRmtInvErrDescr managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.30.1.8 |
cucsVnicProfileSetFsmRmtInvRsltCisco UCS vnic:ProfileSet:fsmRmtInvRslt managed object propertyro CucsConditionRemoteInvRslt (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.30.1.9 |
cucsVnicProfileSetFsmStageDescrCisco UCS vnic:ProfileSet:fsmStageDescr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.30.1.10 |
cucsVnicProfileSetFsmStampCisco UCS vnic:ProfileSet:fsmStamp managed object propertyro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.30.1.11 |
cucsVnicProfileSetFsmStatusCisco UCS vnic:ProfileSet:fsmStatus managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.30.1.12 |
cucsVnicProfileSetFsmTryCisco UCS vnic:ProfileSet:fsmTry managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.30.1.13 |
cucsVnicProfileSetFltAggrCisco UCS vnic:ProfileSet:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.30.1.14 |
cucsVnicProfileSetGenNumCisco UCS vnic:ProfileSet:genNum managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.30.1.15 |
cucsVnicProfileSetVlanGroupUpdateCisco UCS vnic:ProfileSet:vlanGroupUpdate managed
object propertyro CucsVnicVlanGroupUpdate (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.30.1.16 |
cucsVnicProfileSetFsmTaskTableCisco UCS vnic:ProfileSetFsmTask managed object table SEQUENCE OF CucsVnicProfileSetFsmTaskEntry .1.3.6.1.4.1.9.9.719.1.53.31 |
cucsVnicProfileSetFsmTaskEntryEntry for the cucsVnicProfileSetFsmTaskTable table. CucsVnicProfileSetFsmTaskEntry .1.3.6.1.4.1.9.9.719.1.53.31.1 |
cucsVnicProfileSetFsmTaskInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.31.1.1 |
cucsVnicProfileSetFsmTaskDnCisco UCS vnic:ProfileSetFsmTask:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.31.1.2 |
cucsVnicProfileSetFsmTaskRnCisco UCS vnic:ProfileSetFsmTask:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.31.1.3 |
cucsVnicProfileSetFsmTaskCompletionCisco UCS vnic:ProfileSetFsmTask:completion managed
object propertyro CucsFsmCompletion (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.31.1.4 |
cucsVnicProfileSetFsmTaskFlagsCisco UCS vnic:ProfileSetFsmTask:flags managed object propertyro CucsFsmFlags (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.31.1.5 |
cucsVnicProfileSetFsmTaskItemCisco UCS vnic:ProfileSetFsmTask:item managed object propertyro CucsVnicProfileSetFsmTaskItem (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.31.1.6 |
cucsVnicProfileSetFsmTaskSeqIdCisco UCS vnic:ProfileSetFsmTask:seqId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.31.1.7 |
cucsVnicSanConnTemplTableCisco UCS vnic:SanConnTempl managed object table SEQUENCE OF CucsVnicSanConnTemplEntry .1.3.6.1.4.1.9.9.719.1.53.32 |
cucsVnicSanConnTemplEntryEntry for the cucsVnicSanConnTemplTable table. CucsVnicSanConnTemplEntry .1.3.6.1.4.1.9.9.719.1.53.32.1 |
cucsVnicSanConnTemplInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.1 |
cucsVnicSanConnTemplDnCisco UCS vnic:SanConnTempl:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.2 |
cucsVnicSanConnTemplRnCisco UCS vnic:SanConnTempl:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.3 |
cucsVnicSanConnTemplDescrCisco UCS vnic:SanConnTempl:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.4 |
cucsVnicSanConnTemplIdentPoolNameCisco UCS vnic:SanConnTempl:identPoolName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.5 |
cucsVnicSanConnTemplIntIdCisco UCS vnic:SanConnTempl:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.6 |
cucsVnicSanConnTemplMaxDataFieldSizeCisco UCS vnic:SanConnTempl:maxDataFieldSize managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.32.1.7 |
cucsVnicSanConnTemplNameCisco UCS vnic:SanConnTempl:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.8 |
cucsVnicSanConnTemplNwCtrlPolicyNameCisco UCS vnic:SanConnTempl:nwCtrlPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.9 |
cucsVnicSanConnTemplOperIdentPoolNameCisco UCS vnic:SanConnTempl:operIdentPoolName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.10 |
cucsVnicSanConnTemplOperQosPolicyNameCisco UCS vnic:SanConnTempl:operQosPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.11 |
cucsVnicSanConnTemplOperStatsPolicyNameCisco UCS vnic:SanConnTempl:operStatsPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.12 |
cucsVnicSanConnTemplPinToGroupNameCisco UCS vnic:SanConnTempl:pinToGroupName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.13 |
cucsVnicSanConnTemplQosPolicyNameCisco UCS vnic:SanConnTempl:qosPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.14 |
cucsVnicSanConnTemplStatsPolicyNameCisco UCS vnic:SanConnTempl:statsPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.15 |
cucsVnicSanConnTemplSwitchIdCisco UCS vnic:SanConnTempl:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.16 |
cucsVnicSanConnTemplTargetCisco UCS vnic:SanConnTempl:target managed object propertyro CucsVnicSanConnTemplTarget (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.17 |
cucsVnicSanConnTemplTemplTypeCisco UCS vnic:SanConnTempl:templType managed object propertyro CucsVnicTemplateType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.18 |
cucsVnicSanConnTemplPolicyLevelCisco UCS vnic:SanConnTempl:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.32.1.19 |
cucsVnicSanConnTemplPolicyOwnerCisco UCS vnic:SanConnTempl:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.20 |
cucsVnicSanConnTemplOperPeerRedundancyTemplNameCisco UCS vnic:SanConnTempl:operPeerRedundancyTemplName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.21 |
cucsVnicSanConnTemplPeerRedundancyTemplNameCisco UCS vnic:SanConnTempl:peerRedundancyTemplName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.22 |
cucsVnicSanConnTemplRedundancyPairTypeCisco UCS vnic:SanConnTempl:redundancyPairType
managed object propertyro CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.32.1.23 |
cucsVnicScsiTableCisco UCS vnic:Scsi managed object table SEQUENCE OF CucsVnicScsiEntry .1.3.6.1.4.1.9.9.719.1.53.33 |
cucsVnicScsiEntryEntry for the cucsVnicScsiTable table. CucsVnicScsiEntry .1.3.6.1.4.1.9.9.719.1.53.33.1 |
cucsVnicScsiInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.1 |
cucsVnicScsiDnCisco UCS vnic:Scsi:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.2 |
cucsVnicScsiRnCisco UCS vnic:Scsi:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.3 |
cucsVnicScsiAdaptorProfileNameCisco UCS vnic:Scsi:adaptorProfileName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.4 |
cucsVnicScsiAdminVconCisco UCS vnic:Scsi:adminVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.5 |
cucsVnicScsiBootDevCisco UCS vnic:Scsi:bootDev managed object propertyro CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.6 |
cucsVnicScsiConfigStateCisco UCS vnic:Scsi:configState managed object propertyro CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.7 |
cucsVnicScsiEquipmentDnCisco UCS vnic:Scsi:equipmentDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.8 |
cucsVnicScsiIdentPoolNameCisco UCS vnic:Scsi:identPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.9 |
cucsVnicScsiInstTypeCisco UCS vnic:Scsi:instType managed object propertyro CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.10 |
cucsVnicScsiNameCisco UCS vnic:Scsi:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.11 |
cucsVnicScsiNwTemplNameCisco UCS vnic:Scsi:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.12 |
cucsVnicScsiOperOrderCisco UCS vnic:Scsi:operOrder managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.33.1.13 |
cucsVnicScsiOperSpeedCisco UCS vnic:Scsi:operSpeed managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.33.1.14 |
cucsVnicScsiOperStatsPolicyNameCisco UCS vnic:Scsi:operStatsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.15 |
cucsVnicScsiOperVconCisco UCS vnic:Scsi:operVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.16 |
cucsVnicScsiOrderCisco UCS vnic:Scsi:order managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.33.1.17 |
cucsVnicScsiOwnerCisco UCS vnic:Scsi:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.18 |
cucsVnicScsiPinToGroupNameCisco UCS vnic:Scsi:pinToGroupName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.19 |
cucsVnicScsiQosPolicyNameCisco UCS vnic:Scsi:qosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.20 |
cucsVnicScsiStatsPolicyNameCisco UCS vnic:Scsi:statsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.21 |
cucsVnicScsiSwitchIdCisco UCS vnic:Scsi:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.22 |
cucsVnicScsiTypeCisco UCS vnic:Scsi:type managed object propertyro CucsVnicScsiType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.23 |
cucsVnicScsiConfigQualifierCisco UCS vnic:Scsi:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.25 |
cucsVnicScsiAdminHostPortCisco UCS vnic:Scsi:adminHostPort managed object propertyro CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.27 |
cucsVnicScsiOperHostPortCisco UCS vnic:Scsi:operHostPort managed object propertyro CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.28 |
cucsVnicScsiAdminCdnNameCisco UCS vnic:Scsi:adminCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.29 |
cucsVnicScsiOperCdnNameCisco UCS vnic:Scsi:operCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.30 |
cucsVnicScsiCdnPropInSyncCisco UCS vnic:Scsi:cdnPropInSync managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.33.1.31 |
cucsVnicScsiCdnSourceCisco UCS vnic:Scsi:cdnSource managed object propertyro CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.32 |
cucsVnicScsiRedundancyPairTypeCisco UCS vnic:Scsi:redundancyPairType managed object propertyro CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.33 |
cucsVnicScsiRedundancyPeerCisco UCS vnic:Scsi:redundancyPeer managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.33.1.34 |
cucsVnicScsiIfTableCisco UCS vnic:ScsiIf managed object table SEQUENCE OF CucsVnicScsiIfEntry .1.3.6.1.4.1.9.9.719.1.53.34 |
cucsVnicScsiIfEntryEntry for the cucsVnicScsiIfTable table. CucsVnicScsiIfEntry .1.3.6.1.4.1.9.9.719.1.53.34.1 |
cucsVnicScsiIfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.1 |
cucsVnicScsiIfDnCisco UCS vnic:ScsiIf:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.2 |
cucsVnicScsiIfRnCisco UCS vnic:ScsiIf:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.3 |
cucsVnicScsiIfAddrCisco UCS vnic:ScsiIf:addr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.34.1.4 |
cucsVnicScsiIfNameCisco UCS vnic:ScsiIf:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.5 |
cucsVnicScsiIfOperStateCisco UCS vnic:ScsiIf:operState managed object propertyro CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.6 |
cucsVnicScsiIfOwnerCisco UCS vnic:ScsiIf:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.7 |
cucsVnicScsiIfSwitchIdCisco UCS vnic:ScsiIf:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.8 |
cucsVnicScsiIfTypeCisco UCS vnic:ScsiIf:type managed object propertyro CucsVnicAScsiIfType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.9 |
cucsVnicScsiIfVnetCisco UCS vnic:ScsiIf:vnet managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.34.1.10 |
cucsVnicScsiIfConfigQualifierCisco UCS vnic:ScsiIf:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.11 |
cucsVnicScsiIfOperVnetDnCisco UCS vnic:ScsiIf:operVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.13 |
cucsVnicScsiIfOperVnetNameCisco UCS vnic:ScsiIf:operVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.14 |
cucsVnicScsiIfPubNwIdCisco UCS vnic:ScsiIf:pubNwId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.34.1.15 |
cucsVnicScsiIfSharingCisco UCS vnic:ScsiIf:sharing managed object propertyro CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.16 |
cucsVnicScsiIfOperPrimaryVnetDnCisco UCS vnic:ScsiIf:operPrimaryVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.17 |
cucsVnicScsiIfOperPrimaryVnetNameCisco UCS vnic:ScsiIf:operPrimaryVnetName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.34.1.18 |
cucsVnicBootIpPolicyTableCisco UCS vnic:BootIpPolicy managed object table SEQUENCE OF CucsVnicBootIpPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.35 |
cucsVnicBootIpPolicyEntryEntry for the cucsVnicBootIpPolicyTable table. CucsVnicBootIpPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.35.1 |
cucsVnicBootIpPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.35.1.1 |
cucsVnicBootIpPolicyDnCisco UCS vnic:BootIpPolicy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.35.1.2 |
cucsVnicBootIpPolicyRnCisco UCS vnic:BootIpPolicy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.35.1.3 |
cucsVnicBootIpPolicyDescrCisco UCS vnic:BootIpPolicy:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.35.1.4 |
cucsVnicBootIpPolicyIntIdCisco UCS vnic:BootIpPolicy:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.35.1.5 |
cucsVnicBootIpPolicyNameCisco UCS vnic:BootIpPolicy:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.35.1.6 |
cucsVnicBootIpPolicyPoolNameCisco UCS vnic:BootIpPolicy:poolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.35.1.7 |
cucsVnicBootIpPolicyPolicyLevelCisco UCS vnic:BootIpPolicy:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.35.1.8 |
cucsVnicBootIpPolicyPolicyOwnerCisco UCS vnic:BootIpPolicy:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.35.1.9 |
cucsVnicIPv4IscsiAddrTableCisco UCS vnic:IPv4IscsiAddr managed object table SEQUENCE OF CucsVnicIPv4IscsiAddrEntry .1.3.6.1.4.1.9.9.719.1.53.36 |
cucsVnicIPv4IscsiAddrEntryEntry for the cucsVnicIPv4IscsiAddrTable table. CucsVnicIPv4IscsiAddrEntry .1.3.6.1.4.1.9.9.719.1.53.36.1 |
cucsVnicIPv4IscsiAddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.36.1.1 |
cucsVnicIPv4IscsiAddrDnCisco UCS vnic:IPv4IscsiAddr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.36.1.2 |
cucsVnicIPv4IscsiAddrRnCisco UCS vnic:IPv4IscsiAddr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.36.1.3 |
cucsVnicIPv4IscsiAddrAddrCisco UCS vnic:IPv4IscsiAddr:addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.36.1.4 |
cucsVnicIPv4IscsiAddrDefGwCisco UCS vnic:IPv4IscsiAddr:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.36.1.5 |
cucsVnicIPv4IscsiAddrPrimDnsCisco UCS vnic:IPv4IscsiAddr:primDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.36.1.6 |
cucsVnicIPv4IscsiAddrSecDnsCisco UCS vnic:IPv4IscsiAddr:secDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.36.1.7 |
cucsVnicIPv4IscsiAddrSubnetCisco UCS vnic:IPv4IscsiAddr:subnet managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.36.1.8 |
cucsVnicIPv4PooledIscsiAddrTableCisco UCS vnic:IPv4PooledIscsiAddr managed object table SEQUENCE OF CucsVnicIPv4PooledIscsiAddrEntry .1.3.6.1.4.1.9.9.719.1.53.37 |
cucsVnicIPv4PooledIscsiAddrEntryEntry for the cucsVnicIPv4PooledIscsiAddrTable table. CucsVnicIPv4PooledIscsiAddrEntry .1.3.6.1.4.1.9.9.719.1.53.37.1 |
cucsVnicIPv4PooledIscsiAddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.37.1.1 |
cucsVnicIPv4PooledIscsiAddrDnCisco UCS vnic:IPv4PooledIscsiAddr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.37.1.2 |
cucsVnicIPv4PooledIscsiAddrRnCisco UCS vnic:IPv4PooledIscsiAddr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.37.1.3 |
cucsVnicIPv4PooledIscsiAddrAddrCisco UCS vnic:IPv4PooledIscsiAddr:addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.37.1.4 |
cucsVnicIPv4PooledIscsiAddrDefGwCisco UCS vnic:IPv4PooledIscsiAddr:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.37.1.5 |
cucsVnicIPv4PooledIscsiAddrIdentPoolNameCisco UCS vnic:IPv4PooledIscsiAddr:identPoolName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.37.1.6 |
cucsVnicIPv4PooledIscsiAddrOperIdentPoolNameCisco UCS vnic:IPv4PooledIscsiAddr:operIdentPoolName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.37.1.7 |
cucsVnicIPv4PooledIscsiAddrPrimDnsCisco UCS vnic:IPv4PooledIscsiAddr:primDns managed
object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.37.1.8 |
cucsVnicIPv4PooledIscsiAddrSecDnsCisco UCS vnic:IPv4PooledIscsiAddr:secDns managed
object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.37.1.9 |
cucsVnicIPv4PooledIscsiAddrSubnetCisco UCS vnic:IPv4PooledIscsiAddr:subnet managed
object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.37.1.10 |
cucsVnicIScsiTableCisco UCS vnic:IScsi managed object table SEQUENCE OF CucsVnicIScsiEntry .1.3.6.1.4.1.9.9.719.1.53.38 |
cucsVnicIScsiEntryEntry for the cucsVnicIScsiTable table. CucsVnicIScsiEntry .1.3.6.1.4.1.9.9.719.1.53.38.1 |
cucsVnicIScsiInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.1 |
cucsVnicIScsiDnCisco UCS vnic:IScsi:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.2 |
cucsVnicIScsiRnCisco UCS vnic:IScsi:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.3 |
cucsVnicIScsiAdaptorProfileNameCisco UCS vnic:IScsi:adaptorProfileName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.4 |
cucsVnicIScsiAddrCisco UCS vnic:IScsi:addr managed object propertyro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.38.1.5 |
cucsVnicIScsiAdminVconCisco UCS vnic:IScsi:adminVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.6 |
cucsVnicIScsiAuthProfileNameCisco UCS vnic:IScsi:authProfileName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.7 |
cucsVnicIScsiBootDevCisco UCS vnic:IScsi:bootDev managed object propertyro CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.8 |
cucsVnicIScsiConfigStateCisco UCS vnic:IScsi:configState managed object propertyro CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.10 |
cucsVnicIScsiEquipmentDnCisco UCS vnic:IScsi:equipmentDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.11 |
cucsVnicIScsiEthEpDnCisco UCS vnic:IScsi:ethEpDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.12 |
cucsVnicIScsiExtIPStateCisco UCS vnic:IScsi:extIPState managed object propertyro CucsVnicExternalMgmtIPMode (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.13 |
cucsVnicIScsiFltAggrCisco UCS vnic:IScsi:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.38.1.14 |
cucsVnicIScsiIdentPoolNameCisco UCS vnic:IScsi:identPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.15 |
cucsVnicIScsiInitiatorNameCisco UCS vnic:IScsi:initiatorName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.16 |
cucsVnicIScsiInstTypeCisco UCS vnic:IScsi:instType managed object propertyro CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.17 |
cucsVnicIScsiIqnIdentPoolNameCisco UCS vnic:IScsi:iqnIdentPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.18 |
cucsVnicIScsiNameCisco UCS vnic:IScsi:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.19 |
cucsVnicIScsiNwTemplNameCisco UCS vnic:IScsi:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.20 |
cucsVnicIScsiOperAdaptorProfileNameCisco UCS vnic:IScsi:operAdaptorProfileName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.21 |
cucsVnicIScsiOperAuthProfileNameCisco UCS vnic:IScsi:operAuthProfileName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.22 |
cucsVnicIScsiOperIqnIdentPoolNameCisco UCS vnic:IScsi:operIqnIdentPoolName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.24 |
cucsVnicIScsiOperOrderCisco UCS vnic:IScsi:operOrder managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.38.1.25 |
cucsVnicIScsiOperSpeedCisco UCS vnic:IScsi:operSpeed managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.38.1.27 |
cucsVnicIScsiOperStatsPolicyNameCisco UCS vnic:IScsi:operStatsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.28 |
cucsVnicIScsiOperVconCisco UCS vnic:IScsi:operVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.29 |
cucsVnicIScsiOrderCisco UCS vnic:IScsi:order managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.38.1.30 |
cucsVnicIScsiOwnerCisco UCS vnic:IScsi:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.31 |
cucsVnicIScsiPinToGroupNameCisco UCS vnic:IScsi:pinToGroupName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.32 |
cucsVnicIScsiQosPolicyNameCisco UCS vnic:IScsi:qosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.33 |
cucsVnicIScsiStatsPolicyNameCisco UCS vnic:IScsi:statsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.34 |
cucsVnicIScsiSwitchIdCisco UCS vnic:IScsi:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.35 |
cucsVnicIScsiTypeCisco UCS vnic:IScsi:type managed object propertyro CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.36 |
cucsVnicIScsiVnicDefTypeCisco UCS vnic:IScsi:vnicDefType managed object propertyro CucsVnicIScsiIfDefType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.37 |
cucsVnicIScsiVnicNameCisco UCS vnic:IScsi:vnicName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.38 |
cucsVnicIScsiConfigQualifierCisco UCS vnic:IScsi:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.39 |
cucsVnicIScsiInitNameSuffixCisco UCS vnic:IScsi:initNameSuffix managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.40 |
cucsVnicIScsiOperIdentPoolNameCisco UCS vnic:IScsi:operIdentPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.41 |
cucsVnicIScsiAdminHostPortCisco UCS vnic:IScsi:adminHostPort managed object propertyro CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.43 |
cucsVnicIScsiOperHostPortCisco UCS vnic:IScsi:operHostPort managed object propertyro CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.44 |
cucsVnicIScsiPropAclCisco UCS vnic:IScsi:propAcl managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.38.1.45 |
cucsVnicIScsiAdminCdnNameCisco UCS vnic:IScsi:adminCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.47 |
cucsVnicIScsiOperCdnNameCisco UCS vnic:IScsi:operCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.48 |
cucsVnicIScsiCdnSourceCisco UCS vnic:IScsi:cdnSource managed object propertyro CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.49 |
cucsVnicIScsiCdnPropInSyncCisco UCS vnic:IScsi:cdnPropInSync managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.38.1.50 |
cucsVnicIScsiRedundancyPairTypeCisco UCS vnic:IScsi:redundancyPairType managed object propertyro CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.51 |
cucsVnicIScsiRedundancyPeerCisco UCS vnic:IScsi:redundancyPeer managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.38.1.52 |
cucsVnicIScsiAutoTargetIfTableCisco UCS vnic:IScsiAutoTargetIf managed object table SEQUENCE OF CucsVnicIScsiAutoTargetIfEntry .1.3.6.1.4.1.9.9.719.1.53.39 |
cucsVnicIScsiAutoTargetIfEntryEntry for the cucsVnicIScsiAutoTargetIfTable table. CucsVnicIScsiAutoTargetIfEntry .1.3.6.1.4.1.9.9.719.1.53.39.1 |
cucsVnicIScsiAutoTargetIfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.39.1.1 |
cucsVnicIScsiAutoTargetIfDnCisco UCS vnic:IScsiAutoTargetIf:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.39.1.2 |
cucsVnicIScsiAutoTargetIfRnCisco UCS vnic:IScsiAutoTargetIf:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.39.1.3 |
cucsVnicIScsiAutoTargetIfDhcpVendorIdCisco UCS vnic:IScsiAutoTargetIf:dhcpVendorId
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.39.1.4 |
cucsVnicIScsiNodeTableCisco UCS vnic:IScsiNode managed object table SEQUENCE OF CucsVnicIScsiNodeEntry .1.3.6.1.4.1.9.9.719.1.53.40 |
cucsVnicIScsiNodeEntryEntry for the cucsVnicIScsiNodeTable table. CucsVnicIScsiNodeEntry .1.3.6.1.4.1.9.9.719.1.53.40.1 |
cucsVnicIScsiNodeInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.40.1.1 |
cucsVnicIScsiNodeDnCisco UCS vnic:IScsiNode:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.40.1.2 |
cucsVnicIScsiNodeRnCisco UCS vnic:IScsiNode:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.40.1.3 |
cucsVnicIScsiNodeFltAggrCisco UCS vnic:IScsiNode:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.40.1.4 |
cucsVnicIScsiNodeInitiatorNameCisco UCS vnic:IScsiNode:initiatorName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.40.1.5 |
cucsVnicIScsiNodeOwnerCisco UCS vnic:IScsiNode:owner managed object propertyro CucsVnicIScsiNodeOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.40.1.6 |
cucsVnicIScsiNodeInitNameSuffixCisco UCS vnic:IScsiNode:initNameSuffix managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.40.1.7 |
cucsVnicIScsiNodeIqnIdentPoolNameCisco UCS vnic:IScsiNode:iqnIdentPoolName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.40.1.8 |
cucsVnicIScsiNodeOperIqnIdentPoolNameCisco UCS vnic:IScsiNode:operIqnIdentPoolName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.40.1.9 |
cucsVnicIScsiNodeInitiatorPolicyNameCisco UCS vnic:IScsiNode:initiatorPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.40.1.10 |
cucsVnicIScsiNodeOperInitiatorPolicyNameCisco UCS vnic:IScsiNode:operInitiatorPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.40.1.11 |
cucsVnicIScsiNodePropAclCisco UCS vnic:IScsiNode:propAcl managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.40.1.12 |
cucsVnicIScsiStaticTargetIfTableCisco UCS vnic:IScsiStaticTargetIf managed object table SEQUENCE OF CucsVnicIScsiStaticTargetIfEntry .1.3.6.1.4.1.9.9.719.1.53.41 |
cucsVnicIScsiStaticTargetIfEntryEntry for the cucsVnicIScsiStaticTargetIfTable table. CucsVnicIScsiStaticTargetIfEntry .1.3.6.1.4.1.9.9.719.1.53.41.1 |
cucsVnicIScsiStaticTargetIfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.41.1.1 |
cucsVnicIScsiStaticTargetIfDnCisco UCS vnic:IScsiStaticTargetIf:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.41.1.2 |
cucsVnicIScsiStaticTargetIfRnCisco UCS vnic:IScsiStaticTargetIf:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.41.1.3 |
cucsVnicIScsiStaticTargetIfAuthProfileNameCisco UCS vnic:IScsiStaticTargetIf:authProfileName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.41.1.4 |
cucsVnicIScsiStaticTargetIfIpAddressCisco UCS vnic:IScsiStaticTargetIf:ipAddress managed
object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.41.1.5 |
cucsVnicIScsiStaticTargetIfNameCisco UCS vnic:IScsiStaticTargetIf:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.41.1.6 |
cucsVnicIScsiStaticTargetIfOperAuthProfileNameCisco UCS vnic:IScsiStaticTargetIf:operAuthProfileName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.41.1.7 |
cucsVnicIScsiStaticTargetIfPortCisco UCS vnic:IScsiStaticTargetIf:port managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.41.1.8 |
cucsVnicIScsiStaticTargetIfPriorityCisco UCS vnic:IScsiStaticTargetIf:priority managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.41.1.9 |
cucsVnicIScsiStaticTargetIfPropAclCisco UCS vnic:IScsiStaticTargetIf:propAcl managed
object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.41.1.11 |
cucsVnicInternalProfileTableCisco UCS vnic:InternalProfile managed object table SEQUENCE OF CucsVnicInternalProfileEntry .1.3.6.1.4.1.9.9.719.1.53.42 |
cucsVnicInternalProfileEntryEntry for the cucsVnicInternalProfileTable table. CucsVnicInternalProfileEntry .1.3.6.1.4.1.9.9.719.1.53.42.1 |
cucsVnicInternalProfileInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.42.1.1 |
cucsVnicInternalProfileDnCisco UCS vnic:InternalProfile:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.42.1.2 |
cucsVnicInternalProfileRnCisco UCS vnic:InternalProfile:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.42.1.3 |
cucsVnicInternalProfileDescrCisco UCS vnic:InternalProfile:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.42.1.4 |
cucsVnicInternalProfileIntIdCisco UCS vnic:InternalProfile:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.42.1.5 |
cucsVnicInternalProfileMaxPortsCisco UCS vnic:InternalProfile:maxPorts managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.42.1.6 |
cucsVnicInternalProfileNameCisco UCS vnic:InternalProfile:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.42.1.7 |
cucsVnicInternalProfilePolicyLevelCisco UCS vnic:InternalProfile:policyLevel managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.42.1.8 |
cucsVnicInternalProfilePolicyOwnerCisco UCS vnic:InternalProfile:policyOwner managed
object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.42.1.9 |
cucsVnicLunTableCisco UCS vnic:Lun managed object table SEQUENCE OF CucsVnicLunEntry .1.3.6.1.4.1.9.9.719.1.53.43 |
cucsVnicLunEntryEntry for the cucsVnicLunTable table. CucsVnicLunEntry .1.3.6.1.4.1.9.9.719.1.53.43.1 |
cucsVnicLunInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.43.1.1 |
cucsVnicLunDnCisco UCS vnic:Lun:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.43.1.2 |
cucsVnicLunRnCisco UCS vnic:Lun:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.43.1.3 |
cucsVnicLunBootableCisco UCS vnic:Lun:bootable managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.43.1.4 |
cucsVnicLunIdCisco UCS vnic:Lun:id managed object propertyro CucsVnicLunId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.43.1.5 |
cucsVnicOProfileAliasTableCisco UCS vnic:OProfileAlias managed object table SEQUENCE OF CucsVnicOProfileAliasEntry .1.3.6.1.4.1.9.9.719.1.53.44 |
cucsVnicOProfileAliasEntryEntry for the cucsVnicOProfileAliasTable table. CucsVnicOProfileAliasEntry .1.3.6.1.4.1.9.9.719.1.53.44.1 |
cucsVnicOProfileAliasInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.44.1.1 |
cucsVnicOProfileAliasDnCisco UCS vnic:OProfileAlias:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.44.1.2 |
cucsVnicOProfileAliasRnCisco UCS vnic:OProfileAlias:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.44.1.3 |
cucsVnicOProfileAliasAliasCisco UCS vnic:OProfileAlias:alias managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.44.1.4 |
cucsVnicOProfileAliasMgmtPlaneCisco UCS vnic:OProfileAlias:mgmtPlane managed object propertyro CucsVmMgmtPlane (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.44.1.5 |
cucsVnicOProfileAliasVSwitchIdCisco UCS vnic:OProfileAlias:vSwitchId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.44.1.6 |
cucsVnicOProfileAliasVSwitchNameCisco UCS vnic:OProfileAlias:vSwitchName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.44.1.7 |
cucsVnicVlanTableCisco UCS vnic:Vlan managed object table SEQUENCE OF CucsVnicVlanEntry .1.3.6.1.4.1.9.9.719.1.53.45 |
cucsVnicVlanEntryEntry for the cucsVnicVlanTable table. CucsVnicVlanEntry .1.3.6.1.4.1.9.9.719.1.53.45.1 |
cucsVnicVlanInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.1 |
cucsVnicVlanDnCisco UCS vnic:Vlan:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.2 |
cucsVnicVlanRnCisco UCS vnic:Vlan:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.3 |
cucsVnicVlanFltAggrCisco UCS vnic:Vlan:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.45.1.4 |
cucsVnicVlanNameCisco UCS vnic:Vlan:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.5 |
cucsVnicVlanOperStateCisco UCS vnic:Vlan:operState managed object propertyro CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.6 |
cucsVnicVlanOwnerCisco UCS vnic:Vlan:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.7 |
cucsVnicVlanSwitchIdCisco UCS vnic:Vlan:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.8 |
cucsVnicVlanTypeCisco UCS vnic:Vlan:type managed object propertyro CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.9 |
cucsVnicVlanVlanNameCisco UCS vnic:Vlan:vlanName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.10 |
cucsVnicVlanVnetCisco UCS vnic:Vlan:vnet managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.45.1.11 |
cucsVnicVlanConfigQualifierCisco UCS vnic:Vlan:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.12 |
cucsVnicVlanOperVnetDnCisco UCS vnic:Vlan:operVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.14 |
cucsVnicVlanOperVnetNameCisco UCS vnic:Vlan:operVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.15 |
cucsVnicVlanPubNwIdCisco UCS vnic:Vlan:pubNwId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.45.1.16 |
cucsVnicVlanSharingCisco UCS vnic:Vlan:sharing managed object propertyro CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.17 |
cucsVnicVlanOperPrimaryVnetDnCisco UCS vnic:Vlan:operPrimaryVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.18 |
cucsVnicVlanOperPrimaryVnetNameCisco UCS vnic:Vlan:operPrimaryVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.45.1.19 |
cucsVnicConnDefTableCisco UCS vnic:ConnDef managed object table SEQUENCE OF CucsVnicConnDefEntry .1.3.6.1.4.1.9.9.719.1.53.46 |
cucsVnicConnDefEntryEntry for the cucsVnicConnDefTable table. CucsVnicConnDefEntry .1.3.6.1.4.1.9.9.719.1.53.46.1 |
cucsVnicConnDefInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.46.1.1 |
cucsVnicConnDefDnCisco UCS vnic:ConnDef:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.46.1.2 |
cucsVnicConnDefRnCisco UCS vnic:ConnDef:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.46.1.3 |
cucsVnicConnDefFltAggrCisco UCS vnic:ConnDef:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.46.1.4 |
cucsVnicConnDefLanConnPolicyNameCisco UCS vnic:ConnDef:lanConnPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.46.1.5 |
cucsVnicConnDefOperLanConnPolicyNameCisco UCS vnic:ConnDef:operLanConnPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.46.1.6 |
cucsVnicConnDefOperSanConnPolicyNameCisco UCS vnic:ConnDef:operSanConnPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.46.1.7 |
cucsVnicConnDefSanConnPolicyNameCisco UCS vnic:ConnDef:sanConnPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.46.1.8 |
cucsVnicConnDefPropAclCisco UCS vnic:ConnDef:propAcl managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.46.1.9 |
cucsVnicDynamicConPolicyRefTableCisco UCS vnic:DynamicConPolicyRef managed object table SEQUENCE OF CucsVnicDynamicConPolicyRefEntry .1.3.6.1.4.1.9.9.719.1.53.47 |
cucsVnicDynamicConPolicyRefEntryEntry for the cucsVnicDynamicConPolicyRefTable table. CucsVnicDynamicConPolicyRefEntry .1.3.6.1.4.1.9.9.719.1.53.47.1 |
cucsVnicDynamicConPolicyRefInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.47.1.1 |
cucsVnicDynamicConPolicyRefDnCisco UCS vnic:DynamicConPolicyRef:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.47.1.2 |
cucsVnicDynamicConPolicyRefRnCisco UCS vnic:DynamicConPolicyRef:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.47.1.3 |
cucsVnicDynamicConPolicyRefConPolicyNameCisco UCS vnic:DynamicConPolicyRef:conPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.47.1.4 |
cucsVnicDynamicConPolicyRefOperConPolicyNameCisco UCS vnic:DynamicConPolicyRef:operConPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.47.1.5 |
cucsVnicFcGroupDefTableCisco UCS vnic:FcGroupDef managed object table SEQUENCE OF CucsVnicFcGroupDefEntry .1.3.6.1.4.1.9.9.719.1.53.48 |
cucsVnicFcGroupDefEntryEntry for the cucsVnicFcGroupDefTable table. CucsVnicFcGroupDefEntry .1.3.6.1.4.1.9.9.719.1.53.48.1 |
cucsVnicFcGroupDefInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.1 |
cucsVnicFcGroupDefDnCisco UCS vnic:FcGroupDef:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.2 |
cucsVnicFcGroupDefRnCisco UCS vnic:FcGroupDef:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.3 |
cucsVnicFcGroupDefAdaptorProfileNameCisco UCS vnic:FcGroupDef:adaptorProfileName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.4 |
cucsVnicFcGroupDefDescrCisco UCS vnic:FcGroupDef:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.5 |
cucsVnicFcGroupDefIdentPoolNameCisco UCS vnic:FcGroupDef:identPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.6 |
cucsVnicFcGroupDefIntIdCisco UCS vnic:FcGroupDef:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.7 |
cucsVnicFcGroupDefMaxDataFieldSizeCisco UCS vnic:FcGroupDef:maxDataFieldSize managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.48.1.8 |
cucsVnicFcGroupDefNameCisco UCS vnic:FcGroupDef:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.9 |
cucsVnicFcGroupDefNwTemplNameCisco UCS vnic:FcGroupDef:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.10 |
cucsVnicFcGroupDefOperStatsPolicyNameCisco UCS vnic:FcGroupDef:operStatsPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.11 |
cucsVnicFcGroupDefOperStorageConnPolicyNameCisco UCS vnic:FcGroupDef:operStorageConnPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.12 |
cucsVnicFcGroupDefPolicyLevelCisco UCS vnic:FcGroupDef:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.48.1.13 |
cucsVnicFcGroupDefPolicyOwnerCisco UCS vnic:FcGroupDef:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.14 |
cucsVnicFcGroupDefQosPolicyNameCisco UCS vnic:FcGroupDef:qosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.15 |
cucsVnicFcGroupDefStatsPolicyNameCisco UCS vnic:FcGroupDef:statsPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.16 |
cucsVnicFcGroupDefStorageConnPolicyNameCisco UCS vnic:FcGroupDef:storageConnPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.48.1.17 |
cucsVnicFcGroupTemplTableCisco UCS vnic:FcGroupTempl managed object table SEQUENCE OF CucsVnicFcGroupTemplEntry .1.3.6.1.4.1.9.9.719.1.53.49 |
cucsVnicFcGroupTemplEntryEntry for the cucsVnicFcGroupTemplTable table. CucsVnicFcGroupTemplEntry .1.3.6.1.4.1.9.9.719.1.53.49.1 |
cucsVnicFcGroupTemplInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.1 |
cucsVnicFcGroupTemplDnCisco UCS vnic:FcGroupTempl:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.2 |
cucsVnicFcGroupTemplRnCisco UCS vnic:FcGroupTempl:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.3 |
cucsVnicFcGroupTemplAdaptorProfileNameCisco UCS vnic:FcGroupTempl:adaptorProfileName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.4 |
cucsVnicFcGroupTemplDescrCisco UCS vnic:FcGroupTempl:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.5 |
cucsVnicFcGroupTemplIdentPoolNameCisco UCS vnic:FcGroupTempl:identPoolName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.6 |
cucsVnicFcGroupTemplIntIdCisco UCS vnic:FcGroupTempl:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.7 |
cucsVnicFcGroupTemplMaxDataFieldSizeCisco UCS vnic:FcGroupTempl:maxDataFieldSize managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.49.1.8 |
cucsVnicFcGroupTemplNameCisco UCS vnic:FcGroupTempl:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.9 |
cucsVnicFcGroupTemplNwTemplNameCisco UCS vnic:FcGroupTempl:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.10 |
cucsVnicFcGroupTemplOperStatsPolicyNameCisco UCS vnic:FcGroupTempl:operStatsPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.11 |
cucsVnicFcGroupTemplOperStorageConnPolicyNameCisco UCS vnic:FcGroupTempl:operStorageConnPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.12 |
cucsVnicFcGroupTemplPolicyLevelCisco UCS vnic:FcGroupTempl:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.49.1.13 |
cucsVnicFcGroupTemplPolicyOwnerCisco UCS vnic:FcGroupTempl:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.14 |
cucsVnicFcGroupTemplQosPolicyNameCisco UCS vnic:FcGroupTempl:qosPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.15 |
cucsVnicFcGroupTemplStatsPolicyNameCisco UCS vnic:FcGroupTempl:statsPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.16 |
cucsVnicFcGroupTemplStorageConnPolicyNameCisco UCS vnic:FcGroupTempl:storageConnPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.17 |
cucsVnicFcGroupTemplTemplTypeCisco UCS vnic:FcGroupTempl:templType managed object propertyro CucsVnicTemplateType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.18 |
cucsVnicFcGroupTemplRedundancyPairTypeCisco UCS vnic:FcGroupTempl:redundancyPairType
managed object propertyro CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.49.1.19 |
cucsVnicIScsiBootParamsTableCisco UCS vnic:IScsiBootParams managed object table SEQUENCE OF CucsVnicIScsiBootParamsEntry .1.3.6.1.4.1.9.9.719.1.53.50 |
cucsVnicIScsiBootParamsEntryEntry for the cucsVnicIScsiBootParamsTable table. CucsVnicIScsiBootParamsEntry .1.3.6.1.4.1.9.9.719.1.53.50.1 |
cucsVnicIScsiBootParamsInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.50.1.1 |
cucsVnicIScsiBootParamsDnCisco UCS vnic:IScsiBootParams:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.50.1.2 |
cucsVnicIScsiBootParamsRnCisco UCS vnic:IScsiBootParams:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.50.1.3 |
cucsVnicIScsiBootParamsDescrCisco UCS vnic:IScsiBootParams:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.50.1.4 |
cucsVnicIScsiBootParamsIntIdCisco UCS vnic:IScsiBootParams:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.50.1.5 |
cucsVnicIScsiBootParamsNameCisco UCS vnic:IScsiBootParams:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.50.1.6 |
cucsVnicIScsiBootParamsPolicyLevelCisco UCS vnic:IScsiBootParams:policyLevel managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.50.1.7 |
cucsVnicIScsiBootParamsPolicyOwnerCisco UCS vnic:IScsiBootParams:policyOwner managed
object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.50.1.8 |
cucsVnicIScsiBootParamsOwnerCisco UCS vnic:IScsiBootParams:owner managed object propertyro CucsLsOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.50.1.9 |
cucsVnicIScsiBootParamsPropAclCisco UCS vnic:IScsiBootParams:propAcl managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.50.1.10 |
cucsVnicIScsiBootVnicTableCisco UCS vnic:IScsiBootVnic managed object table SEQUENCE OF CucsVnicIScsiBootVnicEntry .1.3.6.1.4.1.9.9.719.1.53.51 |
cucsVnicIScsiBootVnicEntryEntry for the cucsVnicIScsiBootVnicTable table. CucsVnicIScsiBootVnicEntry .1.3.6.1.4.1.9.9.719.1.53.51.1 |
cucsVnicIScsiBootVnicInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.1 |
cucsVnicIScsiBootVnicDnCisco UCS vnic:IScsiBootVnic:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.2 |
cucsVnicIScsiBootVnicRnCisco UCS vnic:IScsiBootVnic:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.3 |
cucsVnicIScsiBootVnicAuthProfileNameCisco UCS vnic:IScsiBootVnic:authProfileName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.4 |
cucsVnicIScsiBootVnicDescrCisco UCS vnic:IScsiBootVnic:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.5 |
cucsVnicIScsiBootVnicInitiatorNameCisco UCS vnic:IScsiBootVnic:initiatorName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.6 |
cucsVnicIScsiBootVnicIntIdCisco UCS vnic:IScsiBootVnic:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.7 |
cucsVnicIScsiBootVnicIqnIdentPoolNameCisco UCS vnic:IScsiBootVnic:iqnIdentPoolName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.8 |
cucsVnicIScsiBootVnicNameCisco UCS vnic:IScsiBootVnic:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.9 |
cucsVnicIScsiBootVnicOperAuthProfileNameCisco UCS vnic:IScsiBootVnic:operAuthProfileName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.10 |
cucsVnicIScsiBootVnicOperIqnIdentPoolNameCisco UCS vnic:IScsiBootVnic:operIqnIdentPoolName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.11 |
cucsVnicIScsiBootVnicPolicyLevelCisco UCS vnic:IScsiBootVnic:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.51.1.12 |
cucsVnicIScsiBootVnicPolicyOwnerCisco UCS vnic:IScsiBootVnic:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.51.1.13 |
cucsVnicIScsiLCPTableCisco UCS vnic:IScsiLCP managed object table SEQUENCE OF CucsVnicIScsiLCPEntry .1.3.6.1.4.1.9.9.719.1.53.52 |
cucsVnicIScsiLCPEntryEntry for the cucsVnicIScsiLCPTable table. CucsVnicIScsiLCPEntry .1.3.6.1.4.1.9.9.719.1.53.52.1 |
cucsVnicIScsiLCPInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.1 |
cucsVnicIScsiLCPDnCisco UCS vnic:IScsiLCP:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.2 |
cucsVnicIScsiLCPRnCisco UCS vnic:IScsiLCP:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.3 |
cucsVnicIScsiLCPAdaptorProfileNameCisco UCS vnic:IScsiLCP:adaptorProfileName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.4 |
cucsVnicIScsiLCPAddrCisco UCS vnic:IScsiLCP:addr managed object propertyro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.52.1.5 |
cucsVnicIScsiLCPAdminVconCisco UCS vnic:IScsiLCP:adminVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.6 |
cucsVnicIScsiLCPBootDevCisco UCS vnic:IScsiLCP:bootDev managed object propertyro CucsVnicVnicBootDev (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.7 |
cucsVnicIScsiLCPConfigQualifierCisco UCS vnic:IScsiLCP:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.8 |
cucsVnicIScsiLCPConfigStateCisco UCS vnic:IScsiLCP:configState managed object propertyro CucsLsConfigState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.9 |
cucsVnicIScsiLCPEquipmentDnCisco UCS vnic:IScsiLCP:equipmentDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.10 |
cucsVnicIScsiLCPFltAggrCisco UCS vnic:IScsiLCP:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.52.1.11 |
cucsVnicIScsiLCPIdentPoolNameCisco UCS vnic:IScsiLCP:identPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.12 |
cucsVnicIScsiLCPInstTypeCisco UCS vnic:IScsiLCP:instType managed object propertyro CucsVnicInstantiation (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.13 |
cucsVnicIScsiLCPNameCisco UCS vnic:IScsiLCP:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.14 |
cucsVnicIScsiLCPNwTemplNameCisco UCS vnic:IScsiLCP:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.15 |
cucsVnicIScsiLCPOperAdaptorProfileNameCisco UCS vnic:IScsiLCP:operAdaptorProfileName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.16 |
cucsVnicIScsiLCPOperIdentPoolNameCisco UCS vnic:IScsiLCP:operIdentPoolName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.17 |
cucsVnicIScsiLCPOperOrderCisco UCS vnic:IScsiLCP:operOrder managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.52.1.18 |
cucsVnicIScsiLCPOperSpeedCisco UCS vnic:IScsiLCP:operSpeed managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.52.1.19 |
cucsVnicIScsiLCPOperStatsPolicyNameCisco UCS vnic:IScsiLCP:operStatsPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.20 |
cucsVnicIScsiLCPOperVconCisco UCS vnic:IScsiLCP:operVcon managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.21 |
cucsVnicIScsiLCPOrderCisco UCS vnic:IScsiLCP:order managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.52.1.22 |
cucsVnicIScsiLCPOwnerCisco UCS vnic:IScsiLCP:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.23 |
cucsVnicIScsiLCPPinToGroupNameCisco UCS vnic:IScsiLCP:pinToGroupName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.24 |
cucsVnicIScsiLCPQosPolicyNameCisco UCS vnic:IScsiLCP:qosPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.25 |
cucsVnicIScsiLCPStatsPolicyNameCisco UCS vnic:IScsiLCP:statsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.26 |
cucsVnicIScsiLCPSwitchIdCisco UCS vnic:IScsiLCP:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.27 |
cucsVnicIScsiLCPTypeCisco UCS vnic:IScsiLCP:type managed object propertyro CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.28 |
cucsVnicIScsiLCPVnicNameCisco UCS vnic:IScsiLCP:vnicName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.29 |
cucsVnicIScsiLCPAdminHostPortCisco UCS vnic:IScsiLCP:adminHostPort managed object propertyro CucsFabricHostPortId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.31 |
cucsVnicIScsiLCPOperHostPortCisco UCS vnic:IScsiLCP:operHostPort managed object propertyro CucsVnicVnicOperHostPort (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.32 |
cucsVnicIScsiLCPAdminCdnNameCisco UCS vnic:IScsiLCP:adminCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.33 |
cucsVnicIScsiLCPOperCdnNameCisco UCS vnic:IScsiLCP:operCdnName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.34 |
cucsVnicIScsiLCPCdnSourceCisco UCS vnic:IScsiLCP:cdnSource managed object propertyro CucsVnicCdnSource (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.35 |
cucsVnicIScsiLCPCdnPropInSyncCisco UCS vnic:IScsiLCP:cdnPropInSync managed object propertyro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.52.1.36 |
cucsVnicIScsiLCPRedundancyPairTypeCisco UCS vnic:IScsiLCP:redundancyPairType managed
object propertyro CucsVnicRedundancyPairType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.37 |
cucsVnicIScsiLCPRedundancyPeerCisco UCS vnic:IScsiLCP:redundancyPeer managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.52.1.38 |
cucsVnicLanConnPolicyTableCisco UCS vnic:LanConnPolicy managed object table SEQUENCE OF CucsVnicLanConnPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.53 |
cucsVnicLanConnPolicyEntryEntry for the cucsVnicLanConnPolicyTable table. CucsVnicLanConnPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.53.1 |
cucsVnicLanConnPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.53.1.1 |
cucsVnicLanConnPolicyDnCisco UCS vnic:LanConnPolicy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.53.1.2 |
cucsVnicLanConnPolicyRnCisco UCS vnic:LanConnPolicy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.53.1.3 |
cucsVnicLanConnPolicyDescrCisco UCS vnic:LanConnPolicy:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.53.1.4 |
cucsVnicLanConnPolicyFltAggrCisco UCS vnic:LanConnPolicy:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.53.1.5 |
cucsVnicLanConnPolicyIntIdCisco UCS vnic:LanConnPolicy:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.53.1.6 |
cucsVnicLanConnPolicyNameCisco UCS vnic:LanConnPolicy:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.53.1.7 |
cucsVnicLanConnPolicyPolicyLevelCisco UCS vnic:LanConnPolicy:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.53.1.8 |
cucsVnicLanConnPolicyPolicyOwnerCisco UCS vnic:LanConnPolicy:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.53.1.9 |
cucsVnicProfileSetFsmTableCisco UCS vnic:ProfileSetFsm managed object table SEQUENCE OF CucsVnicProfileSetFsmEntry .1.3.6.1.4.1.9.9.719.1.53.54 |
cucsVnicProfileSetFsmEntryEntry for the cucsVnicProfileSetFsmTable table. CucsVnicProfileSetFsmEntry .1.3.6.1.4.1.9.9.719.1.53.54.1 |
cucsVnicProfileSetFsmInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.54.1.1 |
cucsVnicProfileSetFsmDnCisco UCS vnic:ProfileSetFsm:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.54.1.2 |
cucsVnicProfileSetFsmRnCisco UCS vnic:ProfileSetFsm:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.54.1.3 |
cucsVnicProfileSetFsmCompletionTimeCisco UCS vnic:ProfileSetFsm:completionTime managed
object propertyro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.54.1.4 |
cucsVnicProfileSetFsmCurrentFsmCisco UCS vnic:ProfileSetFsm:currentFsm managed object propertyro CucsVnicProfileSetFsmCurrentFsm (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.54.1.5 |
cucsVnicProfileSetFsmDescrDataCisco UCS vnic:ProfileSetFsm:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.54.1.6 |
cucsVnicProfileSetFsmFsmStatusCisco UCS vnic:ProfileSetFsm:fsmStatus managed object propertyro CucsFsmFsmStageStatus (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.54.1.7 |
cucsVnicProfileSetFsmProgressCisco UCS vnic:ProfileSetFsm:progress managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.54.1.8 |
cucsVnicProfileSetFsmRmtErrCodeCisco UCS vnic:ProfileSetFsm:rmtErrCode managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.54.1.9 |
cucsVnicProfileSetFsmRmtErrDescrCisco UCS vnic:ProfileSetFsm:rmtErrDescr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.54.1.10 |
cucsVnicProfileSetFsmRmtRsltCisco UCS vnic:ProfileSetFsm:rmtRslt managed object propertyro CucsConditionRemoteInvRslt (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.54.1.11 |
cucsVnicProfileSetFsmStageTableCisco UCS vnic:ProfileSetFsmStage managed object table SEQUENCE OF CucsVnicProfileSetFsmStageEntry .1.3.6.1.4.1.9.9.719.1.53.55 |
cucsVnicProfileSetFsmStageEntryEntry for the cucsVnicProfileSetFsmStageTable table. CucsVnicProfileSetFsmStageEntry .1.3.6.1.4.1.9.9.719.1.53.55.1 |
cucsVnicProfileSetFsmStageInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.55.1.1 |
cucsVnicProfileSetFsmStageDnCisco UCS vnic:ProfileSetFsmStage:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.55.1.2 |
cucsVnicProfileSetFsmStageRnCisco UCS vnic:ProfileSetFsmStage:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.55.1.3 |
cucsVnicProfileSetFsmStageDescrDataCisco UCS vnic:ProfileSetFsmStage:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.55.1.4 |
cucsVnicProfileSetFsmStageLastUpdateTimeCisco UCS vnic:ProfileSetFsmStage:lastUpdateTime
managed object propertyro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.55.1.5 |
cucsVnicProfileSetFsmStageNameCisco UCS vnic:ProfileSetFsmStage:name managed object propertyro CucsVnicProfileSetFsmStageName (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.55.1.6 |
cucsVnicProfileSetFsmStageOrderCisco UCS vnic:ProfileSetFsmStage:order managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.55.1.7 |
cucsVnicProfileSetFsmStageRetryCisco UCS vnic:ProfileSetFsmStage:retry managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.55.1.8 |
cucsVnicProfileSetFsmStageStageStatusCisco UCS vnic:ProfileSetFsmStage:stageStatus
managed object propertyro CucsFsmFsmStageStatus (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.55.1.9 |
cucsVnicRackServerDiscoveryProfileTableCisco UCS vnic:RackServerDiscoveryProfile managed object table SEQUENCE OF CucsVnicRackServerDiscoveryProfileEntry .1.3.6.1.4.1.9.9.719.1.53.56 |
cucsVnicRackServerDiscoveryProfileEntryEntry for the cucsVnicRackServerDiscoveryProfileTable table. CucsVnicRackServerDiscoveryProfileEntry .1.3.6.1.4.1.9.9.719.1.53.56.1 |
cucsVnicRackServerDiscoveryProfileInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.56.1.1 |
cucsVnicRackServerDiscoveryProfileDnCisco UCS vnic:RackServerDiscoveryProfile:dn managed
object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.56.1.2 |
cucsVnicRackServerDiscoveryProfileRnCisco UCS vnic:RackServerDiscoveryProfile:rn managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.56.1.3 |
cucsVnicRackServerDiscoveryProfileDescrCisco UCS vnic:RackServerDiscoveryProfile:descr
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.56.1.4 |
cucsVnicRackServerDiscoveryProfileIntIdCisco UCS vnic:RackServerDiscoveryProfile:intId
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.56.1.5 |
cucsVnicRackServerDiscoveryProfileMaxPortsCisco UCS vnic:RackServerDiscoveryProfile:maxPorts
managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.56.1.6 |
cucsVnicRackServerDiscoveryProfileNameCisco UCS vnic:RackServerDiscoveryProfile:name
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.56.1.7 |
cucsVnicRackServerDiscoveryProfilePolicyLevelCisco UCS vnic:RackServerDiscoveryProfile:policyLevel
managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.56.1.8 |
cucsVnicRackServerDiscoveryProfilePolicyOwnerCisco UCS vnic:RackServerDiscoveryProfile:policyOwner
managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.56.1.9 |
cucsVnicSanConnPolicyTableCisco UCS vnic:SanConnPolicy managed object table SEQUENCE OF CucsVnicSanConnPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.57 |
cucsVnicSanConnPolicyEntryEntry for the cucsVnicSanConnPolicyTable table. CucsVnicSanConnPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.57.1 |
cucsVnicSanConnPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.57.1.1 |
cucsVnicSanConnPolicyDnCisco UCS vnic:SanConnPolicy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.57.1.2 |
cucsVnicSanConnPolicyRnCisco UCS vnic:SanConnPolicy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.57.1.3 |
cucsVnicSanConnPolicyDescrCisco UCS vnic:SanConnPolicy:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.57.1.4 |
cucsVnicSanConnPolicyFltAggrCisco UCS vnic:SanConnPolicy:fltAggr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.57.1.5 |
cucsVnicSanConnPolicyIntIdCisco UCS vnic:SanConnPolicy:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.57.1.6 |
cucsVnicSanConnPolicyNameCisco UCS vnic:SanConnPolicy:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.57.1.7 |
cucsVnicSanConnPolicyPolicyLevelCisco UCS vnic:SanConnPolicy:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.57.1.8 |
cucsVnicSanConnPolicyPolicyOwnerCisco UCS vnic:SanConnPolicy:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.57.1.9 |
cucsVnicVhbaBehPolicyTableCisco UCS vnic:VhbaBehPolicy managed object table SEQUENCE OF CucsVnicVhbaBehPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.58 |
cucsVnicVhbaBehPolicyEntryEntry for the cucsVnicVhbaBehPolicyTable table. CucsVnicVhbaBehPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.58.1 |
cucsVnicVhbaBehPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.58.1.1 |
cucsVnicVhbaBehPolicyDnCisco UCS vnic:VhbaBehPolicy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.58.1.2 |
cucsVnicVhbaBehPolicyRnCisco UCS vnic:VhbaBehPolicy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.58.1.3 |
cucsVnicVhbaBehPolicyActionCisco UCS vnic:VhbaBehPolicy:action managed object propertyro CucsVnicDefaultAction (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.58.1.4 |
cucsVnicVhbaBehPolicyDescrCisco UCS vnic:VhbaBehPolicy:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.58.1.5 |
cucsVnicVhbaBehPolicyIntIdCisco UCS vnic:VhbaBehPolicy:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.58.1.6 |
cucsVnicVhbaBehPolicyNameCisco UCS vnic:VhbaBehPolicy:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.58.1.7 |
cucsVnicVhbaBehPolicyNwTemplNameCisco UCS vnic:VhbaBehPolicy:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.58.1.8 |
cucsVnicVhbaBehPolicyPolicyLevelCisco UCS vnic:VhbaBehPolicy:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.58.1.9 |
cucsVnicVhbaBehPolicyPolicyOwnerCisco UCS vnic:VhbaBehPolicy:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.58.1.10 |
cucsVnicVhbaBehPolicyTypeCisco UCS vnic:VhbaBehPolicy:type managed object propertyro CucsVnicVhbaBehPolicyType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.58.1.11 |
cucsVnicVnicBehPolicyTableCisco UCS vnic:VnicBehPolicy managed object table SEQUENCE OF CucsVnicVnicBehPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.59 |
cucsVnicVnicBehPolicyEntryEntry for the cucsVnicVnicBehPolicyTable table. CucsVnicVnicBehPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.59.1 |
cucsVnicVnicBehPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.59.1.1 |
cucsVnicVnicBehPolicyDnCisco UCS vnic:VnicBehPolicy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.59.1.2 |
cucsVnicVnicBehPolicyRnCisco UCS vnic:VnicBehPolicy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.59.1.3 |
cucsVnicVnicBehPolicyActionCisco UCS vnic:VnicBehPolicy:action managed object propertyro CucsVnicDefaultAction (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.59.1.4 |
cucsVnicVnicBehPolicyDescrCisco UCS vnic:VnicBehPolicy:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.59.1.5 |
cucsVnicVnicBehPolicyIntIdCisco UCS vnic:VnicBehPolicy:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.59.1.6 |
cucsVnicVnicBehPolicyNameCisco UCS vnic:VnicBehPolicy:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.59.1.7 |
cucsVnicVnicBehPolicyNwTemplNameCisco UCS vnic:VnicBehPolicy:nwTemplName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.59.1.8 |
cucsVnicVnicBehPolicyPolicyLevelCisco UCS vnic:VnicBehPolicy:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.59.1.9 |
cucsVnicVnicBehPolicyPolicyOwnerCisco UCS vnic:VnicBehPolicy:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.59.1.10 |
cucsVnicVnicBehPolicyTypeCisco UCS vnic:VnicBehPolicy:type managed object propertyro CucsVnicVnicBehPolicyType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.59.1.11 |
cucsVnicIpV4HistoryTableCisco UCS vnic:IpV4History managed object table SEQUENCE OF CucsVnicIpV4HistoryEntry .1.3.6.1.4.1.9.9.719.1.53.60 |
cucsVnicIpV4HistoryEntryEntry for the cucsVnicIpV4HistoryTable table. CucsVnicIpV4HistoryEntry .1.3.6.1.4.1.9.9.719.1.53.60.1 |
cucsVnicIpV4HistoryInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.60.1.1 |
cucsVnicIpV4HistoryDnCisco UCS vnic:IpV4History:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.60.1.2 |
cucsVnicIpV4HistoryRnCisco UCS vnic:IpV4History:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.60.1.3 |
cucsVnicIpV4HistoryOldIpV4AddrCisco UCS vnic:IpV4History:oldIpV4Addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.60.1.4 |
cucsVnicIqnHistoryTableCisco UCS vnic:IqnHistory managed object table SEQUENCE OF CucsVnicIqnHistoryEntry .1.3.6.1.4.1.9.9.719.1.53.61 |
cucsVnicIqnHistoryEntryEntry for the cucsVnicIqnHistoryTable table. CucsVnicIqnHistoryEntry .1.3.6.1.4.1.9.9.719.1.53.61.1 |
cucsVnicIqnHistoryInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.61.1.1 |
cucsVnicIqnHistoryDnCisco UCS vnic:IqnHistory:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.61.1.2 |
cucsVnicIqnHistoryRnCisco UCS vnic:IqnHistory:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.61.1.3 |
cucsVnicIqnHistoryOldInitiatorNameCisco UCS vnic:IqnHistory:oldInitiatorName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.61.1.4 |
cucsVnicMacHistoryTableCisco UCS vnic:MacHistory managed object table SEQUENCE OF CucsVnicMacHistoryEntry .1.3.6.1.4.1.9.9.719.1.53.62 |
cucsVnicMacHistoryEntryEntry for the cucsVnicMacHistoryTable table. CucsVnicMacHistoryEntry .1.3.6.1.4.1.9.9.719.1.53.62.1 |
cucsVnicMacHistoryInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.62.1.1 |
cucsVnicMacHistoryDnCisco UCS vnic:MacHistory:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.62.1.2 |
cucsVnicMacHistoryRnCisco UCS vnic:MacHistory:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.62.1.3 |
cucsVnicMacHistoryOldaddrCisco UCS vnic:MacHistory:oldaddr managed object propertyro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.719.1.53.62.1.4 |
cucsVnicWwnnHistoryTableCisco UCS vnic:WwnnHistory managed object table SEQUENCE OF CucsVnicWwnnHistoryEntry .1.3.6.1.4.1.9.9.719.1.53.63 |
cucsVnicWwnnHistoryEntryEntry for the cucsVnicWwnnHistoryTable table. CucsVnicWwnnHistoryEntry .1.3.6.1.4.1.9.9.719.1.53.63.1 |
cucsVnicWwnnHistoryInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.63.1.1 |
cucsVnicWwnnHistoryDnCisco UCS vnic:WwnnHistory:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.63.1.2 |
cucsVnicWwnnHistoryRnCisco UCS vnic:WwnnHistory:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.63.1.3 |
cucsVnicWwnnHistoryOldwwnnCisco UCS vnic:WwnnHistory:oldwwnn managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.63.1.4 |
cucsVnicWwpnHistoryTableCisco UCS vnic:WwpnHistory managed object table SEQUENCE OF CucsVnicWwpnHistoryEntry .1.3.6.1.4.1.9.9.719.1.53.64 |
cucsVnicWwpnHistoryEntryEntry for the cucsVnicWwpnHistoryTable table. CucsVnicWwpnHistoryEntry .1.3.6.1.4.1.9.9.719.1.53.64.1 |
cucsVnicWwpnHistoryInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.64.1.1 |
cucsVnicWwpnHistoryDnCisco UCS vnic:WwpnHistory:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.64.1.2 |
cucsVnicWwpnHistoryRnCisco UCS vnic:WwpnHistory:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.64.1.3 |
cucsVnicWwpnHistoryOldaddrCisco UCS vnic:WwpnHistory:oldaddr managed object propertyro Unsigned64 (CISCO-TC) .1.3.6.1.4.1.9.9.719.1.53.64.1.4 |
cucsVnicIpV4MgmtPooledAddrTableCisco UCS vnic:IpV4MgmtPooledAddr managed object table SEQUENCE OF CucsVnicIpV4MgmtPooledAddrEntry .1.3.6.1.4.1.9.9.719.1.53.65 |
cucsVnicIpV4MgmtPooledAddrEntryEntry for the cucsVnicIpV4MgmtPooledAddrTable table. CucsVnicIpV4MgmtPooledAddrEntry .1.3.6.1.4.1.9.9.719.1.53.65.1 |
cucsVnicIpV4MgmtPooledAddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.65.1.1 |
cucsVnicIpV4MgmtPooledAddrDnCisco UCS vnic:IpV4MgmtPooledAddr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.65.1.2 |
cucsVnicIpV4MgmtPooledAddrRnCisco UCS vnic:IpV4MgmtPooledAddr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.65.1.3 |
cucsVnicIpV4MgmtPooledAddrAddrCisco UCS vnic:IpV4MgmtPooledAddr:addr managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.65.1.4 |
cucsVnicIpV4MgmtPooledAddrDefGwCisco UCS vnic:IpV4MgmtPooledAddr:defGw managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.65.1.5 |
cucsVnicIpV4MgmtPooledAddrNameCisco UCS vnic:IpV4MgmtPooledAddr:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.65.1.6 |
cucsVnicIpV4MgmtPooledAddrOperNameCisco UCS vnic:IpV4MgmtPooledAddr:operName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.65.1.7 |
cucsVnicIpV4MgmtPooledAddrSubnetCisco UCS vnic:IpV4MgmtPooledAddr:subnet managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.65.1.8 |
cucsVnicIpV4MgmtPooledAddrPrimDnsCisco UCS vnic:IpV4MgmtPooledAddr:primDns managed
object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.65.1.9 |
cucsVnicIpV4MgmtPooledAddrSecDnsCisco UCS vnic:IpV4MgmtPooledAddr:secDns managed object propertyro InetAddressIPv4 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.65.1.10 |
cucsVnicIpV6MgmtPooledAddrTableCisco UCS vnic:IpV6MgmtPooledAddr managed object table SEQUENCE OF CucsVnicIpV6MgmtPooledAddrEntry .1.3.6.1.4.1.9.9.719.1.53.66 |
cucsVnicIpV6MgmtPooledAddrEntryEntry for the cucsVnicIpV6MgmtPooledAddrTable table. CucsVnicIpV6MgmtPooledAddrEntry .1.3.6.1.4.1.9.9.719.1.53.66.1 |
cucsVnicIpV6MgmtPooledAddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.66.1.1 |
cucsVnicIpV6MgmtPooledAddrDnCisco UCS vnic:IpV6MgmtPooledAddr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.66.1.2 |
cucsVnicIpV6MgmtPooledAddrRnCisco UCS vnic:IpV6MgmtPooledAddr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.66.1.3 |
cucsVnicIpV6MgmtPooledAddrAddrCisco UCS vnic:IpV6MgmtPooledAddr:addr managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.66.1.4 |
cucsVnicIpV6MgmtPooledAddrDefGwCisco UCS vnic:IpV6MgmtPooledAddr:defGw managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.66.1.5 |
cucsVnicIpV6MgmtPooledAddrNameCisco UCS vnic:IpV6MgmtPooledAddr:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.66.1.6 |
cucsVnicIpV6MgmtPooledAddrOperNameCisco UCS vnic:IpV6MgmtPooledAddr:operName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.66.1.7 |
cucsVnicIpV6MgmtPooledAddrPrefixCisco UCS vnic:IpV6MgmtPooledAddr:prefix managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.66.1.8 |
cucsVnicIpV6MgmtPooledAddrPrimDnsCisco UCS vnic:IpV6MgmtPooledAddr:primDns managed
object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.66.1.9 |
cucsVnicIpV6MgmtPooledAddrSecDnsCisco UCS vnic:IpV6MgmtPooledAddr:secDns managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.66.1.10 |
cucsVnicIpV6StaticAddrTableCisco UCS vnic:IpV6StaticAddr managed object table SEQUENCE OF CucsVnicIpV6StaticAddrEntry .1.3.6.1.4.1.9.9.719.1.53.67 |
cucsVnicIpV6StaticAddrEntryEntry for the cucsVnicIpV6StaticAddrTable table. CucsVnicIpV6StaticAddrEntry .1.3.6.1.4.1.9.9.719.1.53.67.1 |
cucsVnicIpV6StaticAddrInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.67.1.1 |
cucsVnicIpV6StaticAddrDnCisco UCS vnic:IpV6StaticAddr:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.67.1.2 |
cucsVnicIpV6StaticAddrRnCisco UCS vnic:IpV6StaticAddr:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.67.1.3 |
cucsVnicIpV6StaticAddrAddrCisco UCS vnic:IpV6StaticAddr:addr managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.67.1.4 |
cucsVnicIpV6StaticAddrDefGwCisco UCS vnic:IpV6StaticAddr:defGw managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.67.1.5 |
cucsVnicIpV6StaticAddrPrefixCisco UCS vnic:IpV6StaticAddr:prefix managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.67.1.6 |
cucsVnicIpV6StaticAddrPrimDnsCisco UCS vnic:IpV6StaticAddr:primDns managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.67.1.7 |
cucsVnicIpV6StaticAddrSecDnsCisco UCS vnic:IpV6StaticAddr:secDns managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.67.1.8 |
cucsVnicProfileRefTableCisco UCS vnic:ProfileRef managed object table SEQUENCE OF CucsVnicProfileRefEntry .1.3.6.1.4.1.9.9.719.1.53.68 |
cucsVnicProfileRefEntryEntry for the cucsVnicProfileRefTable table. CucsVnicProfileRefEntry .1.3.6.1.4.1.9.9.719.1.53.68.1 |
cucsVnicProfileRefInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.68.1.1 |
cucsVnicProfileRefDnCisco UCS vnic:ProfileRef:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.68.1.2 |
cucsVnicProfileRefRnCisco UCS vnic:ProfileRef:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.68.1.3 |
cucsVnicProfileRefNameCisco UCS vnic:ProfileRef:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.68.1.4 |
cucsVnicProfileRefSourceDnCisco UCS vnic:ProfileRef:sourceDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.68.1.5 |
cucsVnicUsnicConPolicyTableCisco UCS vnic:UsnicConPolicy managed object table SEQUENCE OF CucsVnicUsnicConPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.69 |
cucsVnicUsnicConPolicyEntryEntry for the cucsVnicUsnicConPolicyTable table. CucsVnicUsnicConPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.69.1 |
cucsVnicUsnicConPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.69.1.1 |
cucsVnicUsnicConPolicyDnCisco UCS vnic:UsnicConPolicy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.69.1.2 |
cucsVnicUsnicConPolicyRnCisco UCS vnic:UsnicConPolicy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.69.1.3 |
cucsVnicUsnicConPolicyAdaptorProfileNameCisco UCS vnic:UsnicConPolicy:adaptorProfileName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.69.1.4 |
cucsVnicUsnicConPolicyDescrCisco UCS vnic:UsnicConPolicy:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.69.1.5 |
cucsVnicUsnicConPolicyIntIdCisco UCS vnic:UsnicConPolicy:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.69.1.6 |
cucsVnicUsnicConPolicyNameCisco UCS vnic:UsnicConPolicy:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.69.1.7 |
cucsVnicUsnicConPolicyPolicyLevelCisco UCS vnic:UsnicConPolicy:policyLevel managed
object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.69.1.8 |
cucsVnicUsnicConPolicyPolicyOwnerCisco UCS vnic:UsnicConPolicy:policyOwner managed
object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.69.1.9 |
cucsVnicUsnicConPolicyUsnicCountCisco UCS vnic:UsnicConPolicy:usnicCount managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.69.1.10 |
cucsVnicUsnicConPolicyRefTableCisco UCS vnic:UsnicConPolicyRef managed object table SEQUENCE OF CucsVnicUsnicConPolicyRefEntry .1.3.6.1.4.1.9.9.719.1.53.70 |
cucsVnicUsnicConPolicyRefEntryEntry for the cucsVnicUsnicConPolicyRefTable table. CucsVnicUsnicConPolicyRefEntry .1.3.6.1.4.1.9.9.719.1.53.70.1 |
cucsVnicUsnicConPolicyRefInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.70.1.1 |
cucsVnicUsnicConPolicyRefDnCisco UCS vnic:UsnicConPolicyRef:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.70.1.2 |
cucsVnicUsnicConPolicyRefRnCisco UCS vnic:UsnicConPolicyRef:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.70.1.3 |
cucsVnicUsnicConPolicyRefConPolicyNameCisco UCS vnic:UsnicConPolicyRef:conPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.70.1.4 |
cucsVnicUsnicConPolicyRefOperConPolicyNameCisco UCS vnic:UsnicConPolicyRef:operConPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.70.1.5 |
cucsVnicVmqConPolicyTableCisco UCS vnic:VmqConPolicy managed object table SEQUENCE OF CucsVnicVmqConPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.71 |
cucsVnicVmqConPolicyEntryEntry for the cucsVnicVmqConPolicyTable table. CucsVnicVmqConPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.71.1 |
cucsVnicVmqConPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.71.1.1 |
cucsVnicVmqConPolicyDnCisco UCS vnic:VmqConPolicy:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.71.1.2 |
cucsVnicVmqConPolicyRnCisco UCS vnic:VmqConPolicy:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.71.1.3 |
cucsVnicVmqConPolicyDescrCisco UCS vnic:VmqConPolicy:descr managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.71.1.4 |
cucsVnicVmqConPolicyIntIdCisco UCS vnic:VmqConPolicy:intId managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.71.1.5 |
cucsVnicVmqConPolicyIntrCountCisco UCS vnic:VmqConPolicy:intrCount managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.71.1.6 |
cucsVnicVmqConPolicyNameCisco UCS vnic:VmqConPolicy:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.71.1.7 |
cucsVnicVmqConPolicyPolicyLevelCisco UCS vnic:VmqConPolicy:policyLevel managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.71.1.8 |
cucsVnicVmqConPolicyPolicyOwnerCisco UCS vnic:VmqConPolicy:policyOwner managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.71.1.9 |
cucsVnicVmqConPolicyVmqCountCisco UCS vnic:VmqConPolicy:vmqCount managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.71.1.10 |
cucsVnicVmqConPolicyRefTableCisco UCS vnic:VmqConPolicyRef managed object table SEQUENCE OF CucsVnicVmqConPolicyRefEntry .1.3.6.1.4.1.9.9.719.1.53.72 |
cucsVnicVmqConPolicyRefEntryEntry for the cucsVnicVmqConPolicyRefTable table. CucsVnicVmqConPolicyRefEntry .1.3.6.1.4.1.9.9.719.1.53.72.1 |
cucsVnicVmqConPolicyRefInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.72.1.1 |
cucsVnicVmqConPolicyRefDnCisco UCS vnic:VmqConPolicyRef:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.72.1.2 |
cucsVnicVmqConPolicyRefRnCisco UCS vnic:VmqConPolicyRef:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.72.1.3 |
cucsVnicVmqConPolicyRefConPolicyNameCisco UCS vnic:VmqConPolicyRef:conPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.72.1.4 |
cucsVnicVmqConPolicyRefOperConPolicyNameCisco UCS vnic:VmqConPolicyRef:operConPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.72.1.5 |
cucsVnicIpV6HistoryTableCisco UCS vnic:IpV6History managed object table SEQUENCE OF CucsVnicIpV6HistoryEntry .1.3.6.1.4.1.9.9.719.1.53.73 |
cucsVnicIpV6HistoryEntryEntry for the cucsVnicIpV6HistoryTable table. CucsVnicIpV6HistoryEntry .1.3.6.1.4.1.9.9.719.1.53.73.1 |
cucsVnicIpV6HistoryInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.73.1.1 |
cucsVnicIpV6HistoryDnCisco UCS vnic:IpV6History:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.73.1.2 |
cucsVnicIpV6HistoryRnCisco UCS vnic:IpV6History:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.73.1.3 |
cucsVnicIpV6HistoryOldIpV6AddrCisco UCS vnic:IpV6History:oldIpV6Addr managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.73.1.4 |
cucsVnicEthConfigTableCisco UCS vnic:EthConfig managed object table SEQUENCE OF CucsVnicEthConfigEntry .1.3.6.1.4.1.9.9.719.1.53.74 |
cucsVnicEthConfigEntryEntry for the cucsVnicEthConfigTable table. CucsVnicEthConfigEntry .1.3.6.1.4.1.9.9.719.1.53.74.1 |
cucsVnicEthConfigInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.1 |
cucsVnicEthConfigDnCisco UCS vnic:EthConfig:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.2 |
cucsVnicEthConfigRnCisco UCS vnic:EthConfig:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.3 |
cucsVnicEthConfigAdaptorProfileNameCisco UCS vnic:EthConfig:adaptorProfileName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.4 |
cucsVnicEthConfigMacPoolNameCisco UCS vnic:EthConfig:macPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.5 |
cucsVnicEthConfigNwCtrlPolicyNameCisco UCS vnic:EthConfig:nwCtrlPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.6 |
cucsVnicEthConfigOperAdaptorProfileNameCisco UCS vnic:EthConfig:operAdaptorProfileName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.7 |
cucsVnicEthConfigOperMacPoolNameCisco UCS vnic:EthConfig:operMacPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.8 |
cucsVnicEthConfigOperNwCtrlPolicyNameCisco UCS vnic:EthConfig:operNwCtrlPolicyName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.9 |
cucsVnicEthConfigOperStatsPolicyNameCisco UCS vnic:EthConfig:operStatsPolicyName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.10 |
cucsVnicEthConfigStatsPolicyNameCisco UCS vnic:EthConfig:statsPolicyName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.74.1.11 |
cucsVnicIPv6IfTableCisco UCS vnic:IPv6If managed object table SEQUENCE OF CucsVnicIPv6IfEntry .1.3.6.1.4.1.9.9.719.1.53.75 |
cucsVnicIPv6IfEntryEntry for the cucsVnicIPv6IfTable table. CucsVnicIPv6IfEntry .1.3.6.1.4.1.9.9.719.1.53.75.1 |
cucsVnicIPv6IfInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.1 |
cucsVnicIPv6IfDnCisco UCS vnic:IPv6If:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.2 |
cucsVnicIPv6IfRnCisco UCS vnic:IPv6If:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.3 |
cucsVnicIPv6IfAddrCisco UCS vnic:IPv6If:addr managed object propertyro InetAddressIPv6 (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.4 |
cucsVnicIPv6IfConfigQualifierCisco UCS vnic:IPv6If:configQualifier managed object propertyro CucsVnicConfigIssues (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.5 |
cucsVnicIPv6IfNameCisco UCS vnic:IPv6If:name managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.6 |
cucsVnicIPv6IfOperStateCisco UCS vnic:IPv6If:operState managed object propertyro CucsVnicIfOperState (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.7 |
cucsVnicIPv6IfOperVnetDnCisco UCS vnic:IPv6If:operVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.8 |
cucsVnicIPv6IfOperVnetNameCisco UCS vnic:IPv6If:operVnetName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.9 |
cucsVnicIPv6IfOwnerCisco UCS vnic:IPv6If:owner managed object propertyro CucsVnicConnectionOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.10 |
cucsVnicIPv6IfPubNwIdCisco UCS vnic:IPv6If:pubNwId managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.75.1.11 |
cucsVnicIPv6IfSharingCisco UCS vnic:IPv6If:sharing managed object propertyro CucsFabricVlanSharingType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.12 |
cucsVnicIPv6IfSwitchIdCisco UCS vnic:IPv6If:switchId managed object propertyro CucsNetworkSwitchId (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.13 |
cucsVnicIPv6IfTypeCisco UCS vnic:IPv6If:type managed object propertyro CucsVnicConnectionType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.14 |
cucsVnicIPv6IfVnetCisco UCS vnic:IPv6If:vnet managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.75.1.15 |
cucsVnicIPv6IfOperPrimaryVnetDnCisco UCS vnic:IPv6If:operPrimaryVnetDn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.16 |
cucsVnicIPv6IfOperPrimaryVnetNameCisco UCS vnic:IPv6If:operPrimaryVnetName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.75.1.17 |
cucsVnicIScsiConfigTableCisco UCS vnic:IScsiConfig managed object table SEQUENCE OF CucsVnicIScsiConfigEntry .1.3.6.1.4.1.9.9.719.1.53.76 |
cucsVnicIScsiConfigEntryEntry for the cucsVnicIScsiConfigTable table. CucsVnicIScsiConfigEntry .1.3.6.1.4.1.9.9.719.1.53.76.1 |
cucsVnicIScsiConfigInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.1 |
cucsVnicIScsiConfigDnCisco UCS vnic:IScsiConfig:dn managed object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.2 |
cucsVnicIScsiConfigRnCisco UCS vnic:IScsiConfig:rn managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.3 |
cucsVnicIScsiConfigAdaptorProfileNameCisco UCS vnic:IScsiConfig:adaptorProfileName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.4 |
cucsVnicIScsiConfigIpPoolNameCisco UCS vnic:IScsiConfig:ipPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.5 |
cucsVnicIScsiConfigIpPoolNameFabricBCisco UCS vnic:IScsiConfig:ipPoolNameFabricB managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.6 |
cucsVnicIScsiConfigIpPoolTypeCisco UCS vnic:IScsiConfig:ipPoolType managed object propertyro CucsVnicIpPoolType (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.7 |
cucsVnicIScsiConfigIqnPoolNameCisco UCS vnic:IScsiConfig:iqnPoolName managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.8 |
cucsVnicIScsiConfigOperAdaptorProfileNameCisco UCS vnic:IScsiConfig:operAdaptorProfileName
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.9 |
cucsVnicIScsiConfigOperIpPoolNameCisco UCS vnic:IScsiConfig:operIpPoolName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.10 |
cucsVnicIScsiConfigOperIpPoolNameFabricBCisco UCS vnic:IScsiConfig:operIpPoolNameFabricB
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.11 |
cucsVnicIScsiConfigOperIqnPoolNameCisco UCS vnic:IScsiConfig:operIqnPoolName managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.76.1.12 |
cucsVnicIScsiInitAutoConfigPolicyTableCisco UCS vnic:IScsiInitAutoConfigPolicy managed object table SEQUENCE OF CucsVnicIScsiInitAutoConfigPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.77 |
cucsVnicIScsiInitAutoConfigPolicyEntryEntry for the cucsVnicIScsiInitAutoConfigPolicyTable table. CucsVnicIScsiInitAutoConfigPolicyEntry .1.3.6.1.4.1.9.9.719.1.53.77.1 |
cucsVnicIScsiInitAutoConfigPolicyInstanceIdInstance identifier of the managed object. CucsManagedObjectId (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.77.1.1 |
cucsVnicIScsiInitAutoConfigPolicyDnCisco UCS vnic:IScsiInitAutoConfigPolicy:dn managed
object propertyro CucsManagedObjectDn (CISCO-UNIFIED-COMPUTING-MIB) .1.3.6.1.4.1.9.9.719.1.53.77.1.2 |
cucsVnicIScsiInitAutoConfigPolicyRnCisco UCS vnic:IScsiInitAutoConfigPolicy:rn managed
object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.77.1.3 |
cucsVnicIScsiInitAutoConfigPolicyDescrCisco UCS vnic:IScsiInitAutoConfigPolicy:descr
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.77.1.4 |
cucsVnicIScsiInitAutoConfigPolicyFabricPathCisco UCS vnic:IScsiInitAutoConfigPolicy:fabricPath
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.77.1.5 |
cucsVnicIScsiInitAutoConfigPolicyIntIdCisco UCS vnic:IScsiInitAutoConfigPolicy:intId
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.77.1.6 |
cucsVnicIScsiInitAutoConfigPolicyNameCisco UCS vnic:IScsiInitAutoConfigPolicy:name
managed object propertyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.719.1.53.77.1.7 |
cucsVnicIScsiInitAutoConfigPolicyPolicyLevelCisco UCS vnic:IScsiInitAutoConfigPolicy:policyLevel
managed object propertyro Gauge32 .1.3.6.1.4.1.9.9.719.1.53.77.1.8 |
cucsVnicIScsiInitAutoConfigPolicyPolicyOwnerCisco UCS vnic:IScsiInitAutoConfigPolicy:policyOwner
managed object propertyro CucsPolicyPolicyOwner (CISCO-UNIFIED-COMPUTING-TC-MIB) .1.3.6.1.4.1.9.9.719.1.53.77.1.9 |