Home/Catalog/SIAE-SENSOR-TEMP-MIB

SIAE-SENSOR-TEMP-MIB

AI MIB Summary

The SIAE-SENSOR-TEMP-MIB enables SNMP-based monitoring of thermal sensor data on SIAE equipment, specifically tracking real-time temperature metrics to facilitate hardware overheating detection and thermal management.

Management information for equipment heat.
Main OID:
sensorTemp.1.3.6.1.4.1.3373.1103.77
25
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

25 total
Object Name
sensorTempManagement information for equipment heat.
MODULE-IDENTITY
.1.3.6.1.4.1.3373.1103.77
sensorTempMibVersionNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.ro
INTEGER
.1.3.6.1.4.1.3373.1103.77.1
sensorTempTableTable with sensorTemp device entries
SEQUENCE OF SensorTempEntry
.1.3.6.1.4.1.3373.1103.77.2
sensorTempEntryTemperature Sensor entry
SensorTempEntry
.1.3.6.1.4.1.3373.1103.77.2.1
sensorTempIndexTemperature Sensor index.ro
Integer32
.1.3.6.1.4.1.3373.1103.77.2.1.1
sensorTempValueValue of the temperature (in Celsius).ro
Integer32
.1.3.6.1.4.1.3373.1103.77.2.1.2
sensorTempThreshold1This object can not be modified. It reports the temperature threshold 1. When sensorTempValue exceeds this value sensorTempStatus1 becomes Active. When threshold has been exceed status returns stand-by only when sensorTempValue goes under sensorTempHysteresis1.ro
Integer32
.1.3.6.1.4.1.3373.1103.77.2.1.3
sensorTempThreshold2This object can not be modified. It reports the temperature threshold 2. When sensorTempValue exceeds this value sensorTempStatus2 becomes Active. When threshold has been exceed status returns stand-by only when sensorTempValue goes under sensorTempHysteresis2.ro
Integer32
.1.3.6.1.4.1.3373.1103.77.2.1.4
sensorTempHysteresis1This object can not be modified. It reports the temperature hysteresis 1. When sensorTempStatus1 is Active it represents the value under which returns cleared.ro
Integer32
.1.3.6.1.4.1.3373.1103.77.2.1.5
sensorTempHysteresis2This object can not be modified. It reports the temperature hysteresis 2. When sensorTempStatus1 is Active it represents the value under which returns cleared.ro
Integer32
.1.3.6.1.4.1.3373.1103.77.2.1.6
sensorTempStatus1This object is used to manage temperature related to sensorTempThreshold1. Values mean: cleared: sensorTempValue is lower than threshold1 active: sensorTempValue is greater than threshold1 hysteresis: sensorTempValue is between threshold1 and hysteresis1 but previuosly greater than thresold1.ro
Enumeration
.1.3.6.1.4.1.3373.1103.77.2.1.7
sensorTempStatus2This object is used to manage temperature related to sensorTempThreshold2. Values mean: cleared: sensorTempValue is lower than threshold2 active: sensorTempValue is greater than threshold2 hysteresis: sensorTempValue is between threshold2 and hysteresis2 but previuosly greater than thresold2.ro
Enumeration
.1.3.6.1.4.1.3373.1103.77.2.1.8
sensorTempLabelA textual string containing information on sensorTemp sensor.ro
DisplayString
.1.3.6.1.4.1.3373.1103.77.2.1.9
sensorTempAlarmThreshold1This object is used to notiy alarm if at least one entry in the sensorTemp table has got sensorTempStatus1 alarmed.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.77.3
sensorTempAlarmThreshold2This object is used to notiy alarm if at least one entry in the sensorTemp table has got sensorTempStatus2 alarmed.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.77.4
sensorTempAlarmThreshold1SeverityThis object is used to change severity of sensorTempAlarmThreshold1.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.77.5
sensorTempAlarmThreshold2SeverityThis object is used to change severity of sensorTempAlarmThreshold2.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.77.6
sensorTempMonitorTableTable with sensorTempMonitor entries
SEQUENCE OF SensorTempMonitorEntry
.1.3.6.1.4.1.3373.1103.77.7
sensorTempMonitorEntryTemperature Sensor Monitor entry
SensorTempMonitorEntry
.1.3.6.1.4.1.3373.1103.77.7.1
sensorTempMonitorAdminStatusThe desired state of the temperatuure monitor. When a managed system initializes, all the temperature monitors start with sensorTempMonitorAdminStatus in the down(2) state, it's a default state also. As a result of either explicit management action or per configuration information retained by the managed system, sensorTempMonitorAdminStatus is then changed to the up(1) state (or remains in the down(2) state).rw
Enumeration
.1.3.6.1.4.1.3373.1103.77.7.1.1
sensorTempMonitorOperStatusThe current state of the temperatuure monitor. Usually this object report the same value of sensorTempMonitorAdminStatus. When there is some problem related to the temperature sensor, this object shown the down(2) value even if sensorTempMonitorAdminStatus is set to up(1).ro
Enumeration
.1.3.6.1.4.1.3373.1103.77.7.1.2
sensorTempMonitorMinTempThe minimum value of the temperature measured in the last actual 900 seconds. The value is expressed in degrees Celsius.ro
Integer32
.1.3.6.1.4.1.3373.1103.77.7.1.3
sensorTempMonitorMaxTempThe maximum value of the temperature measured in the last actual 900 seconds. The value is expressed in degrees Celsius.ro
Integer32
.1.3.6.1.4.1.3373.1103.77.7.1.4
sensorTempMonitorAverageTempThe average value of the temperature measured in the last actual 900 seconds. The value is expressed in tenth of degrees Celsius.ro
Integer32
.1.3.6.1.4.1.3373.1103.77.7.1.5
sensorTempMonitorSystemControlThe administrative system control status requested by management for the TEMP-MONITOR feature. The value 'start'(1) indicates that TEMP-MONITOR should be supported in the device on all temperature sensors that have this capability (Those shown in sensorTempMonitorTable). The value shutdown(2) indicates that TEMP-MONITOR should be shutdown in the device on all temperature sensors.rw
Enumeration
.1.3.6.1.4.1.3373.1103.77.8
SIAE-SENSOR-TEMP-MIB - SNMP MIB Reference | MIBs Explorer