Home/Catalog/SIAE-PMG828-MIB

SIAE-PMG828-MIB

AI MIB Summary

The SIAE-PMG828-MIB enables performance monitoring of SIAE radio links and E1 tributaries by tracking ITU-T G.829 compliant error metrics, specifically Block Error Ratio (BLER), Errored Seconds (ES), and Severely Errored Seconds (SES).

Perforfamce Monitoring according to ITU-T G.829 for Radio Link and E1 Tributaries
Main OID:
pmG828.1.3.6.1.4.1.3373.1103.11
47
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

47 total
Object Name
pmG828Perforfamce Monitoring according to ITU-T G.829 for Radio Link and E1 Tributaries
MODULE-IDENTITY
.1.3.6.1.4.1.3373.1103.11
pmG828MibVersionNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.ro
INTEGER
.1.3.6.1.4.1.3373.1103.11.1
pmG828CounterTableTable with PmG828 records: one record for 1+0 configuration and two record for 1+1 configuration.
SEQUENCE OF PmG828CounterRecord
.1.3.6.1.4.1.3373.1103.11.2
pmG828CounterRecordPmG828Counter record.
PmG828CounterRecord
.1.3.6.1.4.1.3373.1103.11.2.1
pmG828TPointIdThis object identifies the Termination Point.ro
Integer32
.1.3.6.1.4.1.3373.1103.11.2.1.1
pmG828CounterBlockIdThis object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 20 15 minutes counters N.16(The oldest 15 min.counters 4 hours before).ro
Integer32
.1.3.6.1.4.1.3373.1103.11.2.1.2
pmG828CounterBlockTypeThe type of the counter block.ro
Enumeration
.1.3.6.1.4.1.3373.1103.11.2.1.3
pmG828CounterBlockStatusStatus of the block counter.ro
Enumeration
.1.3.6.1.4.1.3373.1103.11.2.1.4
pmG828CounterTimeStampThe object is the time when the performance record is closed reported as the second number since 1-Gen-1970.ro
Unsigned32
.1.3.6.1.4.1.3373.1103.11.2.1.5
pmG828BBECounterG828 BBE counter.ro
Counter32
.1.3.6.1.4.1.3373.1103.11.2.1.6
pmG828ESCounterG828 Es counter.ro
Counter32
.1.3.6.1.4.1.3373.1103.11.2.1.7
pmG828SESCounterG828 SES counter.ro
Counter32
.1.3.6.1.4.1.3373.1103.11.2.1.8
pmG828UASCounterG828 UAS counter.ro
Counter32
.1.3.6.1.4.1.3373.1103.11.2.1.9
pmG828SEPCounterG828 SEP counter.ro
Counter32
.1.3.6.1.4.1.3373.1103.11.2.1.10
pmG828TpClassTableTable with PmG828TpClass records: one record for 1+0 configuration and two record for 1+1 configuration.
SEQUENCE OF PmG828TpClassRecord
.1.3.6.1.4.1.3373.1103.11.3
pmG828TpClassRecordPmG828TpClass record.
PmG828TpClassRecord
.1.3.6.1.4.1.3373.1103.11.3.1
pmG828TpClassIdThis object identifies the Termination Point.ro
Integer32
.1.3.6.1.4.1.3373.1103.11.3.1.1
pmG828TpClassStartStopThis object is used to start and to stop the Perfomance Monitoring counter evaluation.rw
Enumeration
.1.3.6.1.4.1.3373.1103.11.3.1.2
pmG828TpClassLabelASCII string used to identify the Tp class: for example: pmG828TpClassBranchId = 1 label = Radio 1 pmG828TpClassBranchId = 2 label = Radio 2 pmG828TpClassBranchId = 3 label = Radio(switched) pmG828TpClassBranchId = 4 label = Trib E1 line side pmG828TpClassBranchId = 5 label = Trib E1 radio side.ro
DisplayString
.1.3.6.1.4.1.3373.1103.11.3.1.3
pmG828TpClassTimeStampro
Unsigned32
.1.3.6.1.4.1.3373.1103.11.3.1.4
pmG828TpClass15MEsAlarm15 minutes ES threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.3.1.5
pmG828TpClass15MSesAlarm15 minutes SES threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.3.1.6
pmG828TpClass15MSepAlarm15 minutes SEP threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.3.1.7
pmG828TpClass24HEsAlarmDaily ES threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.3.1.8
pmG828TpClass24HSesAlarmDaily SES threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.3.1.9
pmG828TpClass24HSepAlarmDaily SEP threshold cross alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.3.1.10
pmG828TpClassUasAlarmUAS alarm with associated severity.ro
AlarmStatus (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.3.1.11
pmG828TpClass15MEsThresholdNumber of ES within 15 minutes to set pmG828TpClass15MEsAlarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.11.3.1.12
pmG828TpClass15MSesThresholdNumber of SES within 15 minutes to set pmG828TpClass15MSesAlarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.11.3.1.13
pmG828TpClass15MSepThresholdNumber of SEP within 15 minutes to set pmG828TpClass15MSepAlarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.11.3.1.14
pmG828TpClass24HEsThresholdNumber of ES within one day to set pmG828TpClass24HEsAlarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.11.3.1.15
pmG828TpClass24HSesThresholdNumber of SES within one day to set pmG828TpClass24HSesAlarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.11.3.1.16
pmG828TpClass24HSepThresholdNumber of SEP within one day to set pmG828TpClass24HSepAlarm (zero value disables the alarm).rw
Integer32
.1.3.6.1.4.1.3373.1103.11.3.1.17
pmG828TpClassRowStatusStatus of this row of pmRxPwrTpClass.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.3373.1103.11.3.1.18
pmG828TpMaintTableTable with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmG828TpClassTable
SEQUENCE OF PmG828TpMaintRecord
.1.3.6.1.4.1.3373.1103.11.4
pmG828TpMaintRecordPmG828 Termination Point Maintenance record.
PmG828TpMaintRecord
.1.3.6.1.4.1.3373.1103.11.4.1
pmG828TpMaintCounterClearThis object is used to clear the Perfomance Monitoring counters.rw
Enumeration
.1.3.6.1.4.1.3373.1103.11.4.1.1
pmG828TpMaintAlarmClearThis object is used to clear the Perfomance Monitoring threshold cross alarms.rw
Enumeration
.1.3.6.1.4.1.3373.1103.11.4.1.2
pmG828NSesSetUASNumber of SES (according G.828) to set UAS.rw
Integer32
.1.3.6.1.4.1.3373.1103.11.5
pmG828NSesResetUASNumber of seconds whitout errors (according G.828) to reset UAS.rw
Integer32
.1.3.6.1.4.1.3373.1103.11.6
pmG828TpClass15MEsAlarmSeverityCodeDefines the severity associated to the pmG828TpClass15MEsAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.7
pmG828TpClass15MSesAlarmSeverityCodeDefine the severity associated to the pmG828TpClass15MSesAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.8
pmG828TpClass24HEsAlarmSeverityCodeDefine the severity associated to the pmG828TpClass15MEsAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.9
pmG828TpClass24HSesAlarmSeverityCodeDefine the severity associated to the pmG828TpClass15MSesAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.10
pmG828TpClassUASAlarmSeverityCodeDefine the severity associated to the pmG828TpClassUASAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.11
pmG828TpClass15MSepAlarmSeverityCodeDefine the severity associated to the pmG828TpClass15MSepAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.12
pmG828TpClass24HSepAlarmSeverityCodeDefine the severity associated to the pmG828TpClass24HSepAlarm and enables/disables the trap generation on status change event.rw
AlarmSeverityCode (SIAE-ALARM-MIB)
.1.3.6.1.4.1.3373.1103.11.13

More MIBs from SIAE MICROELETTRONICA spa

Browse all SIAE MICROELETTRONICA spaMIBs →
SIAE-RADIO-SYSTEM-MIB

The SIAE-RADIO-SYSTEM-MIB facilitates the monitoring and management of SIAE radio transmission infrastructure, specifically exposing performance metrics such as RF link status, signal strength, error rates, and system health indicators for broadcast and telecommunications equipment.

369 objects→
SIAE-PTP-MIB

The SIAE-PTP-MIB module enables monitoring and management of SIAE hardware devices implementing the IEEE 1588-2008 Precision Time Protocol and ITU-T G.8275.1 telecom profile, specifically exposing metrics for clock synchronization states, grandmaster selection, and phase/time offset measurements.

139 objects→
SIAE-SYNC-MIB

The SIAE-SYNC-MIB module manages timing source configuration and synchronization states for SIAE broadcast infrastructure equipment, monitoring critical metrics such as reference clock status, synchronization lock status, and time deviation values to ensure precise frame and data alignment.

73 objects→
SIAE-ALARM-MIB

The SIAE-ALARM-MIB module enables the monitoring of network element alarm state transitions and the retrieval of active alarm entries via SNMP for SIAE-managed infrastructure. It specifically tracks alarm severity, timestamp, and status changes to facilitate real-time fault detection and event logging.

58 objects→
SIAE-SFP-MIB

The SIAE-SFP-MIB enables SNMP-based monitoring and alarm generation for SIAE Small Form-Factor Pluggable optical transceivers, exposing diagnostic parameters defined by SFF-8472 such as temperature, supply voltage, laser bias current, and optical transmit/receive power levels.

56 objects→
SIAE-PMRXPWR-MIB

The SIAE-PMRXPWR-MIB module enables SNMP-based monitoring of received RF power levels within SIAE microwave radio systems, specifically tracking performance metrics such as instantaneous and average RX signal strength to assess link quality and detect signal degradation.

55 objects→