SIAE-EQUIP-MIB
AI MIB Summary
The SIAE-EQUIP-MIB provides standard SNMP access to monitor and manage common operational parameters, including hardware status, environmental sensors, and interface statistics for SIAE (Società Italiana per l'Esercizio Telefonico) telecommunications infrastructure. This module enables centralized visibility into the health and performance of SIAE's proprietary network equipment through defined object identifiers for critical system metrics.
Common parameters of SIAE equipments.
Main OID:
equipment.1.3.6.1.4.1.3373.1103.1
45
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
45 total| Object Name |
|---|
equipLOMConnectedMonitorThis event is generated by ALFOHD-NE when equipLOMConnected is set to Monitor mode. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected NOTIFICATION-TYPE .1.3.6.1.4.1.3373.1103.0.109 |
equipLOMConnectedConfigThis event is generated by ALFOHD-NE when equipLOMConnected is set to Configuration mode. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected NOTIFICATION-TYPE .1.3.6.1.4.1.3373.1103.0.110 |
equipLOMDisconnectedThis event is generated by ALFOHD-NE when LOMConnected is cleared. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipLOMConnected NOTIFICATION-TYPE .1.3.6.1.4.1.3373.1103.0.111 |
equipConfigChangeStatusThis event is generated by ALFOHD-NE when equipConfigChange is changed. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipConfigChange NOTIFICATION-TYPE .1.3.6.1.4.1.3373.1103.0.114 |
equipManagerWakeUpNotifyThis trap is sent periodically only to the manager specified by the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode differs from disable. The data passed with the event are: 1) equipIpSnmpAgentAddress 2) equipStationID 3) equipLocation 4) equipIpSnmpAgentAddress 5) equipGosipAddress 6) equipManagerWakeUpIpAddr 7) equipManagerWakeUpAlarm NOTIFICATION-TYPE .1.3.6.1.4.1.3373.1103.0.123 |
equipmentCommon parameters of SIAE equipments. MODULE-IDENTITY .1.3.6.1.4.1.3373.1103.1 |
equipMibVersionNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.ro INTEGER .1.3.6.1.4.1.3373.1103.1.1 |
equipCurrentTimeSeconds since 1/1/1970.rw TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.3373.1103.1.2 |
equipUpTimeThe time since the system was last re-initialized (in seconds since 1/1/1970).ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.3373.1103.1.3 |
equipTypeType of SIAE MICROELETTRONICA's equipmentro AutonomousType (SNMPv2-TC) .1.3.6.1.4.1.3373.1103.1.4 |
equipIpEthOsiAddressIp address of the equipment on Ethernet-OSI interface.rw IpAddress .1.3.6.1.4.1.3373.1103.1.6 |
equipGosipAddressGOSIP address of the equipment.rw OCTET STRING .1.3.6.1.4.1.3373.1103.1.7 |
equipIpEthOsiNetMaskThe subnet Mask associated with the IP address of OSI ethernet interface. The value of the Mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0.rw IpAddress .1.3.6.1.4.1.3373.1103.1.8 |
equipL1L2IsIsRoutingIt defines the IS-IS routing type: L1 within the same area, L2 among different areas.rw Enumeration .1.3.6.1.4.1.3373.1103.1.9 |
equipStationIDASCII string assigned by the operator to identify the specific equipment.rw DisplayString .1.3.6.1.4.1.3373.1103.1.10 |
equipLOMConfigEnableEnables/disables the capabilityto connect a LOM in Configuration Mode.rw Enumeration .1.3.6.1.4.1.3373.1103.1.11 |
equipLOMConnectedSignal when the LOM is connected to the NE and if the connection is for monitor or configuration.ro Enumeration .1.3.6.1.4.1.3373.1103.1.12 |
equipLOMConnectedTrapEnableEnables/disables the trap generation on EquipLOMConnected status change event.rw Enumeration .1.3.6.1.4.1.3373.1103.1.13 |
equipConfigChangeSet by the NE when the equipment configuration is changed by the local or Remote LOM. The octet string is a bit stream of flags; a set bit is a change on a specific item. We had: Byte 0.7: change in configuration for equipment group Byte 0.6: change in configuration for userInput group Byte 0.5: change in configuration for userOutput group Byte 0.4: change in configuration for alarmLog group ...... Byte 3.7: change in a severity for equipment group Byte 3.6: change in a severity for userInput group Byte 3.5: change in a severity for userOutput group Byte 3.4: change in a severity for alarmLog group CEM can reset the change condition writing one to desired bit flag ......rw OCTET STRING .1.3.6.1.4.1.3373.1103.1.14 |
equipConfigChangeTrapEnableEnables/disables the trap generation on EquipConfigChange status change event.rw Enumeration .1.3.6.1.4.1.3373.1103.1.15 |
equipRequestForce Equipment Controller restart or change in interface properties.rw Enumeration .1.3.6.1.4.1.3373.1103.1.16 |
equipIpEthAddressIp address of the equipment on Ethernet interface.rw IpAddress .1.3.6.1.4.1.3373.1103.1.17 |
equipIpEthNetMaskThe subnet Mask associated with the IP address of ethernet interface. The value of the Mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0.rw IpAddress .1.3.6.1.4.1.3373.1103.1.18 |
equipOsiamParameterIt defines the set-up parameter for OSI stack.rw OCTET STRING .1.3.6.1.4.1.3373.1103.1.19 |
equipIpSnmpAgentAddressIp address used by SNMP Agent for mark generated TRAP.rw IpAddress .1.3.6.1.4.1.3373.1103.1.20 |
equipOperationInProgressA value different from 0 means operation in progress.rw Integer32 .1.3.6.1.4.1.3373.1103.1.21 |
equipManagerWakeUpAlarmThis alarm switches on when periodic connection wake-up trap starts. The trap related to this alarm is also sent periodically only to the manager specified by the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode differs from disable.ro AlarmStatus (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.1.22 |
equipManagerWakeUpAlarmSeverityCodeDefines the severity associated to the equipManagerWakeUpAlarm and enables/disables the trap generation on status change event.rw AlarmSeverityCode (SIAE-ALARM-MIB) .1.3.6.1.4.1.3373.1103.1.23 |
equipManagerWakeUpTimeoutThis object defines the time (in minutes) after which the periodic connection wake-up trap is stopped. The maximium value is equivalent to 24 hours. When the timeout elapses the equipManagerWakeUpAlarmSeverityCode is set to disable. A zero means no timeout.rw INTEGER .1.3.6.1.4.1.3373.1103.1.24 |
equipManagerWakeUpIpAddrIp Address of manager wich to send a periodic connection wake-up trap. The periodic trap is sent only if the equipManagerWakeUpAlarmSeverityCode differs from disable. If Ip Address equals 0 no trap will be sent.rw IpAddress .1.3.6.1.4.1.3373.1103.1.25 |
equipManagerWakeUpGosipAddressGosip Address of manager wich to send a periodic connection wake-up trap.rw OCTET STRING .1.3.6.1.4.1.3373.1103.1.26 |
equipManagerWakeUpTrapVersionTrap version supported by Manager to wake-up.rw Enumeration .1.3.6.1.4.1.3373.1103.1.27 |
equipManager1IpAddrFirst IP address of a SNMP Manager always logged to this equipment. The address 0.0.0.0 mean that manager is not present.rw IpAddress .1.3.6.1.4.1.3373.1103.1.28 |
equipManager2IpAddrSecond IP address of a SNMP Manager always logged to this equipment. The address 0.0.0.0 mean that manager is not present.rw IpAddress .1.3.6.1.4.1.3373.1103.1.29 |
equipManager1TrapVersionTrap version supported by Manager 1 (related to equipManager1IpAddr).rw Enumeration .1.3.6.1.4.1.3373.1103.1.30 |
equipManager2TrapVersionTrap version supported by Manager 2 (related to equipManager2IpAddr).rw Enumeration .1.3.6.1.4.1.3373.1103.1.31 |
equipDailyPmTimeZoneReference GMT Time Zone to close the daily P.M. records.rw INTEGER (-12..12) .1.3.6.1.4.1.3373.1103.1.32 |
equipOperationMngtControlstartOperation means the apply of the 'management parameters set' on the E6165 switch. confirmOperation means the backup of the 'management parameters set'.rw Enumeration .1.3.6.1.4.1.3373.1103.1.33 |
equipOperationMngtInProgressA value different from 0 means Mngt operation in progress.ro INTEGER .1.3.6.1.4.1.3373.1103.1.34 |
equipLocationASCII string assigned by the operator to identify the location of specific equipment.rw DisplayString .1.3.6.1.4.1.3373.1103.1.35 |
equipLongitudeGeographic coordinate that specifies the east-west position of the equipment. In order to calculate the latitude in degrees the formula to be applied is Longitude = equipLongitude*180/2^31 This object is used with equipLatitude to locate the equipment on a map.rw INTEGER .1.3.6.1.4.1.3373.1103.1.36 |
equipLatitudeGeographic coordinate that specifies the north-south position of the equipment. In order to calculate the latitude in degrees the formula to be applied is Latitude = equipLatitude*180/2^31 This object is used with equipLongitude to locate the equipment on a map.rw INTEGER .1.3.6.1.4.1.3373.1103.1.37 |
equipIpEthVlanIdEthernet vlan id on top of which management is builtrw Integer32 .1.3.6.1.4.1.3373.1103.1.38 |
equipIpEthDefGatewayIp address of the default gateway on Ethernet interface.rw IpAddress .1.3.6.1.4.1.3373.1103.1.39 |
equipIpEthDefGatewayIfIndexIp address of the default gateway on Ethernet interface.rw InterfaceIndex .1.3.6.1.4.1.3373.1103.1.40 |