SIAE-CARRIER-AGGRL1-MIB
AI MIB Summary
The SIAE-CARRIER-AGGRL1-MIB enables SNMP-based monitoring and configuration of hybrid aggregation functions on SIAE carrier-grade aggregation equipment, specifically tracking session states, link utilization, and aggregation layer topology metrics.
Carrier hybrid aggregation management for SIAE equipments.
Main OID:
carrierAggr.1.3.6.1.4.1.3373.1103.104
21
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
21 total| Object Name |
|---|
carrierAggrCarrier hybrid aggregation management for SIAE equipments. MODULE-IDENTITY .1.3.6.1.4.1.3373.1103.104 |
carrierAggrMibVersionNumerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.ro INTEGER .1.3.6.1.4.1.3373.1103.104.1 |
carrierAggrSensorTableTable with Radio(s) interface(s) that can be associated to an entry of carrierAggrActuatorTable. SEQUENCE OF CarrierAggrSensorEntry .1.3.6.1.4.1.3373.1103.104.2 |
carrierAggrSensorEntryA row in the carrierAggrSensorTable. CarrierAggrSensorEntry .1.3.6.1.4.1.3373.1103.104.2.1 |
carrierAggrSensorIndexThis object identifies the index of carrierAggrSensorTable.ro INTEGER .1.3.6.1.4.1.3373.1103.104.2.1.1 |
carrierAggrSensorRowstatusThe status of this sensor entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value: SensorIfIndex must be set to a valid ifIndex number. Otherwise, the error inconsistentValue is returned on the attempt to set active this row. When this object is set to notInService changes may be made to carrierAggrSensorIfIndex. Other objects can be changed when carrierAggrSensorRowStatus is set to active. A sensor can not be deleted if there is any Actuator (see table carrierAggrActuatorTable) associated with it.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3373.1103.104.2.1.2 |
carrierAggrSensorAdminStatusAdministative status of the sensor. The value down(1) turns off all actuators associated with this sensor.rw Enumeration .1.3.6.1.4.1.3373.1103.104.2.1.3 |
carrierAggrSensorIfIndexThis object accepts a greater than zero value to identify an interface in ifTable. Some parameters of the radio associated to this interface is monitored and a notification is sent to all connected actuators.rw InterfaceIndexOrZero (IF-MIB) .1.3.6.1.4.1.3373.1103.104.2.1.4 |
carrierAggrSensorHitlessCapabilityThis capability is related to HITLESS Behaviour carrierAggrSensorHitlessBehaviour.ro Bits .1.3.6.1.4.1.3373.1103.104.2.1.5 |
carrierAggrSensorHitlessBehaviourThe hitless behaviour. When enabled, data related to the current ACM zone is notified to an external N.E. aggregator, so it can dynamically exclude/include the data-flow without loss of frames. It can be enabled only if carrierAggrSensorHitlessCapability is availablerw Enumeration .1.3.6.1.4.1.3373.1103.104.2.1.6 |
carrierAggrSensorHitlessModeThe policy to select the hitless profile (i.e. the lowest one under which a N.E. aggregator excludes the carrier from an existing aggregation). auto(1): Tx Lower Profile + 1 is selected; manual(2): the value set in carrierAggrSensorHitlessProfile is selected.rw Enumeration .1.3.6.1.4.1.3373.1103.104.2.1.7 |
carrierAggrSensorHitlessProfileThe hitless profile in case of carrierHyAggrHitlessBehaviour set as enabled and carrierHyAggrHitlessMode set as manual.rw INTEGER .1.3.6.1.4.1.3373.1103.104.2.1.8 |
carrierAggrSensorHitlessStatusThe working zone of the radio link.ro Enumeration .1.3.6.1.4.1.3373.1103.104.2.1.9 |
carrierAggrActuatorTableTable with Lan(s) interface that can be associated to an entry of carrierAggrSensorTable. SEQUENCE OF CarrierAggrActuatorEntry .1.3.6.1.4.1.3373.1103.104.3 |
carrierAggrActuatorEntryA row in the carrierAggrActuatorTable. CarrierAggrActuatorEntry .1.3.6.1.4.1.3373.1103.104.3.1 |
carrierAggrActuatorIndexThis object identifies the carrier aggr Actuator inside the Network Element.ro INTEGER .1.3.6.1.4.1.3373.1103.104.3.1.1 |
carrierAggrActuatorRowStatusThe status of this entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value: carrierAggrActuatorIfIndex must be set to a valid ifIndex number and carrierAggrActuatorSensorIndex must be set to a valid sensor, Otherwise, the error inconsistentValue is returned on the attempt to set active this row. When set to notInService changes may be made to carrierAggrActuatorIfIndex and carrierAggrActuatorSensorIndex. Other objects can be changed when carrierAggrActuatorRowStatus is set to active.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3373.1103.104.3.1.2 |
carrierAggrActuatorAdminStatusAdministative status of the actuator. The value down(1) turns it off. Other actuators associated with the same sensor remain active.rw Enumeration .1.3.6.1.4.1.3373.1103.104.3.1.3 |
carrierAggrActuatorIfIndexThis object accepts a greater than zero value to identify an interface in ifTable. The notify received from the connected sensor is forwarded to the remote aggregator to signal some anomalies on this aggregated flow.rw InterfaceIndexOrZero (IF-MIB) .1.3.6.1.4.1.3373.1103.104.3.1.4 |
carrierAggrActuatorSensorIndexThis object connects this actuator to a sensor.rw Integer32 .1.3.6.1.4.1.3373.1103.104.3.1.5 |
carrierAggrActuatorConcIpAddrThis object is used to contain the Ip address of the equipment connected with this Lan (the concatenator unit)ro IpAddress .1.3.6.1.4.1.3373.1103.104.3.1.6 |