REDLINE-AN80I-MIB
AI MIB Summary
The REDLINE-AN80I-MIB module provides SNMP object definitions for monitoring and managing Redline AN80i switched devices, enabling the retrieval of interface statistics, system status, and hardware-specific telemetry. This module facilitates granular visibility into the operational state of the Redline AN80i platform through standard SNMP queries.
This MIB module contains object definitions applicable only to Redline AN80i switched device.
Main OID:
redlineAn80iMib.1.3.6.1.4.1.10728.2.1.3
75
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
75 total| Object Name |
|---|
redlineAn80iMibThis MIB module contains object definitions applicable only to Redline AN80i switched device. MODULE-IDENTITY .1.3.6.1.4.1.10728.2.1.3 |
redlineAn80iTrapDefinitions OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.0 |
an80iPswdChangeFailTrapAn event to report the failure of a password change. NOTIFICATION-TYPE .1.3.6.1.4.1.10728.2.1.3.0.1 |
an80iFirmwareConfigFailTrapAn event to report the failure of a firmware config. NOTIFICATION-TYPE .1.3.6.1.4.1.10728.2.1.3.0.2 |
an80iEepromCorruptedTrapAn event to report the corruption of the EEPROM. NOTIFICATION-TYPE .1.3.6.1.4.1.10728.2.1.3.0.3 |
an80iHardwareFailTrapAn event to report the hardware failure. NOTIFICATION-TYPE .1.3.6.1.4.1.10728.2.1.3.0.4 |
an80iSaveConfigTrapAn event to report the saving of configuration NOTIFICATION-TYPE .1.3.6.1.4.1.10728.2.1.3.0.5 |
an80iDFSEventTrapAn event to report the radar frequency detection NOTIFICATION-TYPE .1.3.6.1.4.1.10728.2.1.3.0.6 |
an80iIdChangedTrapEvent that reports the modification in the configuration of an ID. NOTIFICATION-TYPE .1.3.6.1.4.1.10728.2.1.3.0.7 |
an80iSWUpgradeFailedEvent that reports the failure of a software upgrade opration. NOTIFICATION-TYPE .1.3.6.1.4.1.10728.2.1.3.0.8 |
an80iSWUpgradeSuccessEvent that reports the success of a software upgrade opration. NOTIFICATION-TYPE .1.3.6.1.4.1.10728.2.1.3.0.9 |
redlineAn80iPtpPmpObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.1 |
redlineAn80iSystemObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.1.1 |
an80iOptionsKeyTableThis table contains options key information. The maximum number of configured options key is 2. SEQUENCE OF An80iOptionsKeyEntry .1.3.6.1.4.1.10728.2.1.3.1.1.1 |
an80iOptionsKeyEntryThis table provides one row for each option key defined in the AN80i system An80iOptionsKeyEntry .1.3.6.1.4.1.10728.2.1.3.1.1.1.1 |
an80iOptionsKeyIdThe Options Key Identifier. INTEGER .1.3.6.1.4.1.10728.2.1.3.1.1.1.1.1 |
an80iOptionsKeyThe options key value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.10728.2.1.3.1.1.1.1.2 |
an80iOptionsKeyStatusThis object is used to ctivate and deactivate rows in the an80iOptionsKeyTable table. There will be only two rows in the table and only one will be active. When one row is active the other one will be notInService. The row can not be created or deletedrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.10728.2.1.3.1.1.1.1.3 |
an80iHardwareTypeThe type/version/revision of the hardware.ro Integer32 .1.3.6.1.4.1.10728.2.1.3.1.1.2 |
an80iRadioTypeThe radio type.ro Integer32 .1.3.6.1.4.1.10728.2.1.3.1.1.3 |
an80iSaveConfigThis object will save the configuration in the nonvolatile memory and will activate the new configuration.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.1.4 |
an80iActivateConfigThis object will activate the new configuration without saving it in the nonvolatile memory. If after this event it will elapse more than 5 minutes and no save configuration occurs, then system will restart with the configuration from the nonvolatile memory.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.1.5 |
redlineAn80iWirelesObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.1.2 |
an80iAntennaAllignmentModeSpecifies if the antenna alignment buzzer is enabled or not. In the future, new alignment methods may be added.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.2.1 |
an80iCurrTxPowerThe actual Tx Power of the AN-80i Node.ro INTEGER (-10..20) .1.3.6.1.4.1.10728.2.1.3.1.2.2 |
an80iChannelAutoScanSpecifies if the frequency auto-scanning feature is enabledrw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.2.3 |
an80iCurrFrequencyThe central frequency on which the equipment operates. If the auto-scanning feature is enabled then this may be different than the an80iOPeratingFrequency. [KHz]ro Integer32 UNITS "KHz" .1.3.6.1.4.1.10728.2.1.3.1.2.4 |
an80iOPeratingFrequencySpecifies the operating frequency of the system [KHz].rw Integer32 UNITS "KHz" .1.3.6.1.4.1.10728.2.1.3.1.2.5 |
an80iMaxTxPowerThe Tx Power of the AN-80i. Specifies the power level of the system, which is preset at the factory and should not be altered. In the event that this parameter needs to be changed, please contact the Redline support team.rw INTEGER (-10..20) .1.3.6.1.4.1.10728.2.1.3.1.2.6 |
an80iSystemMode1 = PMP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Masterrw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.2.7 |
an80iRFStatusCodeSpecifies the Error Code for the RF Interface.ro Integer32 .1.3.6.1.4.1.10728.2.1.3.1.2.8 |
an80iDFSActionAction taken when a radar is detected on the same frequency.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.2.9 |
an80iAntennaGainThe gain of the antenna attached to the system.rw Integer32 .1.3.6.1.4.1.10728.2.1.3.1.2.10 |
an80iActiveRFLinksThe actual number of provisioned links.ro Integer32 .1.3.6.1.4.1.10728.2.1.3.1.2.11 |
an80iAtpControlEnable/disable the automatic Tx power control.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.2.12 |
an80iTurboModeControlEnable/disable the turbo mode. In this mode the system uses a 40MHz channel (20 MHz in normal mode).rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.2.13 |
an80iChannelWidthThe width of the channel.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.2.14 |
redlineAn80iEthernetObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.1.3 |
an80iEtherPortConnSpecifies Ethernet port connection auto(1), mdi(2) or mdix(3)rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.3.1 |
an80iEtherPortModeThe attribute specifies the Ethernet LED status of the AN80i.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.3.2 |
an80iFlowControlThis object specifies if flow control is enabled or not.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.3.3 |
an80iLowLatencyModeThis object specifies if prioritized low latency mode is enabled or not.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.3.4 |
an80iEthernetFollowsWirelessThis object specifies if the Ethernet follows wireless mode is enabled or not.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.3.5 |
an80iEthernetFollowsWirelessTimeoutThis object specifies if the timeout (seconds) for the Ethernet follows wireless mode (0=infinite).rw INTEGER .1.3.6.1.4.1.10728.2.1.3.1.3.6 |
redlineAn80iManagObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.1.4 |
an80iHttpAccessThis object specifies if Http Access is enabled or not.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.4.1 |
an80iTelnetAccessThis object specifies if Telnet Access is enabled or not.rw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.4.2 |
an80iTelnetPortThis object specifies the Telnet port number.rw InetPortNumber (INET-ADDRESS-MIB) .1.3.6.1.4.1.10728.2.1.3.1.4.3 |
redlineAn80iSWUpgradeObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.1.5 |
an80iSwDownloadTftpAddressTypeThe INET address type of the software upgrade TFTP server. IPv4 type supported only.rw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.10728.2.1.3.1.5.1 |
an80iSwDownloadTftpAddressThe INET address of the TFTP server.rw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.10728.2.1.3.1.5.2 |
an80iSwDownloadTftpFileThe image file name as required by the TFTP server.rw DisplayString .1.3.6.1.4.1.10728.2.1.3.1.5.3 |
an80iSwDownloadStatusThe status of the current software download.ro Enumeration .1.3.6.1.4.1.10728.2.1.3.1.5.4 |
an80iSwDownloadControlTrigger software upgraderw Enumeration .1.3.6.1.4.1.10728.2.1.3.1.5.5 |
redlineAn80iPmpObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.2 |
redlineAn80iPmpWirelesObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.2.1 |
an80iRegistrationPeriodNumber of frames between two consecutive registration periods.rw INTEGER .1.3.6.1.4.1.10728.2.1.3.2.1.1 |
an80iMaximumDistanceMaximum distance in km between the sector controller and one subscriber station.rw INTEGER .1.3.6.1.4.1.10728.2.1.3.2.1.2 |
an80iRegisteredStationsThe number of registered stations on the sector controller.ro Integer32 .1.3.6.1.4.1.10728.2.1.3.2.1.3 |
an80iRegisteredConnectionsThe number of registered connections on the sector controller.ro Integer32 .1.3.6.1.4.1.10728.2.1.3.2.1.4 |
an80iMaxIdThe maximum number of ID used to identify links, connections and groupsro INTEGER .1.3.6.1.4.1.10728.2.1.3.2.1.5 |
an80iNextAvailIdThe next available ID from the ID pool which is not grater then that defined in 'an80iMaxId'ro Integer32 .1.3.6.1.4.1.10728.2.1.3.2.1.6 |
an80iLastModifIdThe last modified ID from the ID pool which is not grater then that defined in 'an80iMaxId'ro Integer32 .1.3.6.1.4.1.10728.2.1.3.2.1.7 |
an80iSaveIdConfigurationSave the ID table in the flash memoryrw Enumeration .1.3.6.1.4.1.10728.2.1.3.2.1.8 |
redlineAn80iPtpObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.3 |
redlineAn80iPtpSystemObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.3.1 |
an80iResetStatisticsThis object resets wireless and Ethernet countersrw Enumeration .1.3.6.1.4.1.10728.2.1.3.3.1.1 |
redlineAn80iConformance OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.5 |
redlineAn80iGroups OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.5.1 |
redlineAn80iPtpPmpGroupAN80i PTP/PMP objects. Unknown .1.3.6.1.4.1.10728.2.1.3.5.1.1 |
redlineAn80iPmpGroupAN80i PMP objects. Unknown .1.3.6.1.4.1.10728.2.1.3.5.1.2 |
redlineAn80iPtpGroupAN80i PTP objects. Unknown .1.3.6.1.4.1.10728.2.1.3.5.1.3 |
redlineAn80iNotificationGroupThe notifications which indicate specific events within the AN80i unit. Unknown .1.3.6.1.4.1.10728.2.1.3.5.1.4 |
redlineAn80iCompls OBJECT IDENTIFIER .1.3.6.1.4.1.10728.2.1.3.5.2 |
redlineAn80iComplianceThe compliance statement for AN80i entities that implement this MIB module. Unknown .1.3.6.1.4.1.10728.2.1.3.5.2.1 |