OMNI-gx2oa100bd-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for OMNI-gx2oa100bd-MIB.
261
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
261 total| Object Name |
|---|
trapOA100BDConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.1 |
trapOA100BDConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.2 |
trapOA100BDModuleTemperatureAlarmThis trap is issued when the OA100B Module's Temperature goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.3 |
trapOA100BDOpticalInPowerAlarmThis trap is issued when the input Optical Input Power parameter
goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.4 |
trapOA100BDOpticalOutPowerAlarmThis trap is issued when the input Optical Output Power parameter
goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.5 |
trapOA100BDMainTECTemperatureAlarmThis trap is issued when the OA100B Main TEC Temperature goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.6 |
trapOA100BDMainLaserPowerAlarmThis trap is issued when the OA100B Main Laser Power goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.7 |
trapOA100BDAuxTECTemperatureAlarmThis trap is issued when the OA100B Aux TEC Temperature goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.8 |
trapOA100BDAuxLaserPowerAlarmThis trap is issued when the OA100B Aux Laser Power goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.9 |
trapOA100BDFanCurrentAlarmThis trap is issued when the OA100B Module's Fan Currrent parameter
goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.10 |
trapOA100BDResetFacDefaultThis trap is issued when the OA100B resets to factory defaults TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.11 |
trapOA100BDStandbyModeThis trap is issued when the OA100B is in Standby Mode. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.12 |
trapOA100BDOptInShutdownThis trap is issued when the OA100B is in Optical Input Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.13 |
trapOA100BDMainTECTempShutdownThis trap is issued when the OA100B is in Main TEC Temperature Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.14 |
trapOA100BDAuxTECTempShutdownThis trap is issued when the OA100B is in Aux TEC Temperature Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.15 |
trapOA100BDKeySwitchThis trap is issued when the Key Switch disables the OA100B. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.16 |
trapOA100BDPowerFailThis trap is issued when there is an OA100B Power Supply Failure. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.17 |
trapOA100BDMainLasCurrShutdownThis trap is issued when the OA100B is in Main Laser Current Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.18 |
trapOA100BDAuxLasCurrShutdownThis trap is issued when the OA100B is in Aux Laser Current Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.19 |
trapOA100BDMainLasPowerShutdownThis trap is issued when the OA100B is in Main Laser Power Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.20 |
trapOA100BDAuxLasPowerShutdownThis trap is issued when the OA100B is in Aux Laser Power Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.21 |
trapOA100BDInvalidModeThis trap is issued when the OA100B is in an invalid mode. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.22 |
trapOA100BDFlashAlarmThis trap is issued when the OA100B Module's boot or flash programming sequence has
detected a Flash error. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.23 |
trapOA100BDBoot0AlarmThis trap is issued when the OA100B Module's Bank 0 Boot sequence has detected an error. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.24 |
trapOA100BDBoot1AlarmThis trap is issued when the OA100B Module's Bank 1 Boot sequence has detected an error. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.25 |
trapOA100BDAlarmDataCRCAlarmThis trap is issued when the OA100B Module detects an error calculating the alarm limit CRC. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.26 |
trapOA100BDFactoryDataCRCAlarmThis trap is issued when the OA100B Module detects an error calculating the Factory data CRC. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.27 |
trapOA100BDCalDataCRCAlarmThis trap is issued when the OA100B Module detects an error calculating the Calibration data CRC. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.28 |
trapOA100BDFacCalFloatAlarmThis trap is issued when the OA100B Module detects factory calibration float data alarm. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.29 |
trapOA100BDOptInThreshAlarmThis trap is issued when the OA100B Module Optical Input drops below the user set threshold. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.30 |
trapOA100BDGainErrorAlarmThis trap is issued when the OA100B Module can not produce the desired user set gain in Constant Gain Set Mode. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.31 |
trapOA100BDHardwareErrorAlarmThis trap is issued when any of the OA100BD Module's TEC,Laser, +12V, or +3.7V current parameters
go out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.17.0.32 |
gx2OA100BDDescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.17.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.17.1 |
gx2OA100BDAnalogTableThis table contains gx2OA100B specific parameters with
nominal and current values. SEQUENCE OF Gx2OA100BDAnalogEntry .1.3.6.1.4.1.1166.6.1.2.17.2 |
gx2OA100BDAnalogEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2OA100BDAnalogEntry .1.3.6.1.4.1.1166.6.1.2.17.2.1 |
gx2OA100BDAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.2.1.1 |
oa100bdlabelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.2 |
oa100bduomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.3 |
oa100bdmajorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.4 |
oa100bdmajorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.5 |
oa100bdminorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.6 |
oa100bdminorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.7 |
oa100bdcurrentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.8 |
oa100bdstateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.9 |
oa100bdminValueModTempThe value of this object provides the minimum value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.10 |
oa100bdmaxValueModTempThe value of this object provides the maximum value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.11 |
oa100bdalarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.12 |
oa100bdlabelOptInPowerThe value of this object provides the label of the
Optical Input Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.13 |
oa100bduomOptInPowerThe value of this object provides the Unit of Measure of the
Optical Input Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.14 |
oa100bdmajorHighOptInPowerThe value of this object provides the Major High alarm value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.15 |
oa100bdmajorLowOptInPowerThe value of this object provides the Major Low alarm value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.16 |
oa100bdminorHighOptInPowerThe value of this object provides the Minor High alarm value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.17 |
oa100bdminorLowOptInPowerThe value of this object provides the Minor Low alarm value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.18 |
oa100bdcurrentValueOptInPowerThe value of this object provides the Current value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.19 |
oa100bdstateFlagOptInPowerThe value of this object provides the state
of the Optical Input Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.20 |
oa100bdminValueOptInPowerThe value of this object provides the minimum value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.21 |
oa100bdmaxValueOptInPowerThe value of this object provides the maximum value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.22 |
oa100bdalarmStateOptInPowerThe value of this object provides the curent alarm state of
the Optical Input Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.23 |
oa100bdlabelOptOutPowerThe value of this object provides the label of the
Optical Output Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.24 |
oa100bduomOptOutPowerThe value of this object provides the Unit of Measure of the
Optical Output Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.25 |
oa100bdmajorHighOptOutPowerThe value of this object provides the Major High alarm value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.26 |
oa100bdmajorLowOptOutPowerThe value of this object provides the Major Low alarm value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.27 |
oa100bdminorHighOptOutPowerThe value of this object provides the Minor High alarm value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.28 |
oa100bdminorLowOptOutPowerThe value of this object provides the Minor Low alarm value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.29 |
oa100bdcurrentValueOptOutPowerThe value of this object provides the Current value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.30 |
oa100bdstateFlagOptOutPowerThe value of this object provides the state
of the Optical Output Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.31 |
oa100bdminValueOptOutPowerThe value of this object provides the minimum value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.32 |
oa100bdmaxValueOptOutPowerThe value of this object provides the maximum value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.33 |
oa100bdalarmStateOptOutPowerThe value of this object provides the curent alarm state of
the Optical Output Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.34 |
oa100bdlabelMainTECTempThe value of this object provides the label of the
TEC Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.35 |
oa100bduomMainTECTempThe value of this object provides the Unit of Measure of the
TEC Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.36 |
oa100bdmajorHighMainTECTempThe value of this object provides the Major High alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.37 |
oa100bdmajorLowMainTECTempThe value of this object provides the Major Low alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.38 |
oa100bdminorHighMainTECTempThe value of this object provides the Minor High alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.39 |
oa100bdminorLowMainTECTempThe value of this object provides the Minor Low alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.40 |
oa100bdcurrentValueMainTECTempThe value of this object provides the Current value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.41 |
oa100bdstateFlagMainTECTempThe value of this object provides the state
of the TEC Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.42 |
oa100bdminValueMainTECTempThe value of this object provides the minimum value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.43 |
oa100bdmaxValueMainTECTempThe value of this object provides the maximum value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.44 |
oa100bdalarmStateMainTECTempThe value of this object provides the curent alarm state of
the TEC Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.45 |
oa100bdlabelMainLaserPowerThe value of this object provides the label of the
Main Laser Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.46 |
oa100bduomMainLaserPowerThe value of this object provides the Unit of Measure of the
Main Laser Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.47 |
oa100bdmajorHighMainLaserPowerThe value of this object provides the Major High alarm value
of the Main Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.48 |
oa100bdmajorLowMainLaserPowerThe value of this object provides the Major Low alarm value
of the Main Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.49 |
oa100bdminorHighMainLaserPowerThe value of this object provides the Minor High alarm value
of the Main Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.50 |
oa100bdminorLowMainLaserPowerThe value of this object provides the Minor Low alarm value
of the Main Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.51 |
oa100bdcurrentValueMainLaserPowerThe value of this object provides the Current value
of the Main Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.52 |
oa100bdstateFlagMainLaserPowerThe value of this object provides the state
of the Main Laser Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.53 |
oa100bdminValueMainLaserPowerThe value of this object provides the minimum value
of the Main Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.54 |
oa100bdmaxValueMainLaserPowerThe value of this object provides the maximum value
of the Main Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.55 |
oa100bdalarmStateMainLaserPowerThe value of this object provides the curent alarm state of
the Main Laser Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.56 |
oa100bdlabelAuxTECTempThe value of this object provides the label of the
TEC Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.57 |
oa100bduomAuxTECTempThe value of this object provides the Unit of Measure of the
TEC Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.58 |
oa100bdmajorHighAuxTECTempThe value of this object provides the Major High alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.59 |
oa100bdmajorLowAuxTECTempThe value of this object provides the Major Low alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.60 |
oa100bdminorHighAuxTECTempThe value of this object provides the Minor High alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.61 |
oa100bdminorLowAuxTECTempThe value of this object provides the Minor Low alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.62 |
oa100bdcurrentValueAuxTECTempThe value of this object provides the Current value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.63 |
oa100bdstateFlagAuxTECTempThe value of this object provides the state
of the TEC Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.64 |
oa100bdminValueAuxTECTempThe value of this object provides the minimum value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.65 |
oa100bdmaxValueAuxTECTempThe value of this object provides the maximum value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.66 |
oa100bdalarmStateAuxTECTempThe value of this object provides the curent alarm state of
the TEC Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.67 |
oa100bdlabelAuxLaserPowerThe value of this object provides the label of the
Aux Laser Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.68 |
oa100bduomAuxLaserPowerThe value of this object provides the Unit of Measure of the
Aux Laser Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.69 |
oa100bdmajorHighAuxLaserPowerThe value of this object provides the Major High alarm value
of the Aux Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.70 |
oa100bdmajorLowAuxLaserPowerThe value of this object provides the Major Low alarm value
of the Aux Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.71 |
oa100bdminorHighAuxLaserPowerThe value of this object provides the Minor High alarm value
of the Aux Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.72 |
oa100bdminorLowAuxLaserPowerThe value of this object provides the Minor Low alarm value
of the Aux Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.73 |
oa100bdcurrentValueAuxLaserPowerThe value of this object provides the Current value
of the Aux Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.74 |
oa100bdstateFlagAuxLaserPowerThe value of this object provides the state
of the Aux Laser Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.75 |
oa100bdminValueAuxLaserPowerThe value of this object provides the minimum value
of the Aux Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.76 |
oa100bdmaxValueAuxLaserPowerThe value of this object provides the maximum value
of the Aux Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.77 |
oa100bdalarmStateAuxLaserPowerThe value of this object provides the curent alarm state of
the Aux Laser Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.78 |
oa100bdlabelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.79 |
oa100bduomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.80 |
oa100bdmajorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.81 |
oa100bdmajorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.82 |
oa100bdminorHighFanCurrentThe value of this object provides the Minor High alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.83 |
oa100bdminorLowFanCurrentThe value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.84 |
oa100bdcurrentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.85 |
oa100bdstateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.86 |
oa100bdminValueFanCurrentThe value of this object provides the minimum value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.87 |
oa100bdmaxValueFanCurrentThe value of this object provides the maximum value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.88 |
oa100bdalarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.89 |
oa100bdlabelOPSettingThe value of this object provides the label of the
Output Power Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.90 |
oa100bduomOPSettingThe value of this object provides the Unit of Measure of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.91 |
oa100bdmajorHighOPSettingThe value of this object provides the Major High alarm value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.92 |
oa100bdmajorLowOPSettingThe value of this object provides the Major Low alarm value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.93 |
oa100bdminorHighOPSettingThe value of this object provides the Minor High alarm value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.94 |
oa100bdminorLowOPSettingThe value of this object provides the Minor Low alarm value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.95 |
oa100bdcurrentValueOPSettingThe value of this object provides the Current value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.96 |
oa100bdstateFlagOPSettingThe value of this object provides the state
of the Output Power Setting Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.97 |
oa100bdminValueOPSettingThe value of this object provides the minimum value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.98 |
oa100bdmaxValueOPSettingThe value of this object provides the maximum value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.99 |
oa100bdalarmStateOPSettingThe value of this object provides the curent alarm state of
the Output Power Setting Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.100 |
oa100bdlabelLPSettingThe value of this object provides the label of the
Laser Power Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.101 |
oa100bduomLPSettingThe value of this object provides the Unit of Measure of the
Laser Power Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.102 |
oa100bdmajorHighLPSettingThe value of this object provides the Major High alarm value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.103 |
oa100bdmajorLowLPSettingThe value of this object provides the Major Low alarm value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.104 |
oa100bdminorHighLPSettingThe value of this object provides the Minor High alarm value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.105 |
oa100bdminorLowLPSettingThe value of this object provides the Minor Low alarm value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.106 |
oa100bdcurrentValueLPSettingThe value of this object provides the Current value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.107 |
oa100bdstateFlagLPSettingThe value of this object provides the state
of the Laser Power Setting Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.108 |
oa100bdminValueLPSettingThe value of this object provides the minimum value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.109 |
oa100bdmaxValueLPSettingThe value of this object provides the maximum value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.110 |
oa100bdalarmStateLPSettingThe value of this object provides the curent alarm state of
the Laser Power Setting Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.111 |
oa100bdlabelCGSettingThe value of this object provides the label of the
Constant Gain Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.112 |
oa100bduomCGSettingThe value of this object provides the Unit of Measure of the
Constant Gain Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.113 |
oa100bdmajorHighCGSettingThe value of this object provides the Major High alarm value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.114 |
oa100bdmajorLowCGSettingThe value of this object provides the Major Low alarm value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.115 |
oa100bdminorHighCGSettingThe value of this object provides the Minor High alarm value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.116 |
oa100bdminorLowCGSettingThe value of this object provides the Minor Low alarm value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.117 |
oa100bdcurrentValueCGSettingThe value of this object provides the Current value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.118 |
oa100bdstateFlagCGSettingThe value of this object provides the state
of the Constant Gain Setting Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.119 |
oa100bdminValueCGSettingThe value of this object provides the minimum value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.120 |
oa100bdmaxValueCGSettingThe value of this object provides the maximum value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.121 |
oa100bdalarmStateCGSettingThe value of this object provides the curent alarm state of
the Constant Gain Setting Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.122 |
oa100bdlabelOptThresholdThe value of this object provides the label of the
Optical Input Threshold Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.123 |
oa100bduomOptThresholdThe value of this object provides the Unit of Measure of the
Optical Input Threshold Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.2.1.124 |
oa100bdmajorHighOptThresholdThe value of this object provides the Major High alarm value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.125 |
oa100bdmajorLowOptThresholdThe value of this object provides the Major Low alarm value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.126 |
oa100bdminorHighOptThresholdThe value of this object provides the Minor High alarm value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.127 |
oa100bdminorLowOptThresholdThe value of this object provides the Minor Low alarm value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.128 |
oa100bdcurrentValueOptThresholdThe value of this object provides the Current value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.129 |
oa100bdstateFlagOptThresholdThe value of this object provides the state
of the Optical Input Threshold Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.130 |
oa100bdminValueOptThresholdThe value of this object provides the minimum value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.131 |
oa100bdmaxValueOptThresholdThe value of this object provides the maximum value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.17.2.1.132 |
oa100bdalarmStateOptThresholdThe value of this object provides the curent alarm state of
the Optical Input Threshold Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.2.1.133 |
gx2OA100BDDigitalTableThis table contains gx2OA100B specific parameters with
nominal and current values. SEQUENCE OF Gx2OA100BDDigitalEntry .1.3.6.1.4.1.1166.6.1.2.17.3 |
gx2OA100BDDigitalEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2OA100BDDigitalEntry .1.3.6.1.4.1.1166.6.1.2.17.3.2 |
gx2OA100BDDigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.3.2.1 |
oa100bdlabelModeSettingThe value of this object provides the label of the
OA100BD's Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.3.2.2 |
oa100bdenumModeSettingThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.3.2.3 |
oa100bdvalueModeSettingThe value of this object is the current value of the parameter. It is an integer
value from 0 to 5 representing the operation mode of the module.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.17.3.2.4 |
oa100bdstateFlagModeSettingThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.3.2.5 |
oa100bdlabelModuleStateThe value of this object provides the label of the
Module State Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.3.2.6 |
oa100bdenumModuleStateThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.3.2.7 |
oa100bdvalueModuleStateThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.17.3.2.8 |
oa100bdstateFlagModuleStateThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.3.2.9 |
oa100bdlabelFactoryDefaultThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.3.2.10 |
oa100bdenumFactoryDefaultThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.3.2.11 |
oa100bdvalueFactoryDefaultThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.17.3.2.12 |
oa100bdstateFlagFactoryDefaultThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.3.2.13 |
gx2OA100BDStatusTableThis table contains gx2OA100B specific parameters with
nominal and current values. SEQUENCE OF Gx2OA100BDStatusEntry .1.3.6.1.4.1.1166.6.1.2.17.4 |
gx2OA100BDStatusEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2OA100BDStatusEntry .1.3.6.1.4.1.1166.6.1.2.17.4.3 |
gx2OA100BDStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.4.3.1 |
oa100bdlabelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.2 |
oa100bdvalueBootThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.3 |
oa100bdstateflagBootThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.4 |
oa100bdlabelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.5 |
oa100bdvalueFlashThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.6 |
oa100bdstateflagFlashThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.7 |
oa100bdlabelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.8 |
oa100bdvalueFactoryDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.9 |
oa100bdstateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.10 |
oa100bdlabelAlarmDataCRCThe value of this object provides the label of the
Alarm Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.11 |
oa100bdvalueAlarmDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.12 |
oa100bdstateflagAlarmDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.13 |
oa100bdlabelCalibrationDataCRCThe value of this object provides the label of the
Calibration Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.14 |
oa100bdvalueCalibrationDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.15 |
oa100bdstateflagCalibrationDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.16 |
oa100bdlabelOptInShutdownThe value of this object provides the label of the
Optical Input Power Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.17 |
oa100bdvalueOptInShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.18 |
oa100bdstateflagOptInShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.19 |
oa100bdlabelMainTECTempShutdownThe value of this object provides the label of the
Main TEC Temperature Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.20 |
oa100bdvalueMainTECTempShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.21 |
oa100bdstateflagMainTECTempShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.22 |
oa100bdlabelAuxTECTempShutdownThe value of this object provides the label of the
Aux TEC Temperature Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.23 |
oa100bdvalueAuxTECTempShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.24 |
oa100bdstateflagAuxTECTempShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.25 |
oa100bdlabelPowerFailThe value of this object provides the label of the
Power Supply Fail Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.26 |
oa100bdvaluePowerFailThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.27 |
oa100bdstateflagPowerFailThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.28 |
oa100bdlabelKeySwitchThe value of this object provides the label of the
Key Switch Setting Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.29 |
oa100bdvalueKeySwitchThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.30 |
oa100bdstateflagKeySwitchThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.31 |
oa100bdlabelMainLaserCurrShutdownThe value of this object provides the label of the
Main Laser Current Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.32 |
oa100bdvalueMainLaserCurrShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.33 |
oa100bdstateflagMainLaserCurrShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.34 |
oa100bdlabelAuxLaserCurrShutdownThe value of this object provides the label of the
AuxLaser Current Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.35 |
oa100bdvalueAuxLaserCurrShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.36 |
oa100bdstateflagAuxLaserCurrShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.37 |
oa100bdlabelMainLaserPowShutdownThe value of this object provides the label of the
Main Laser Power Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.38 |
oa100bdvalueMainLaserPowShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.39 |
oa100bdstateflagMainLaserPowShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.40 |
oa100bdlabelAuxLaserPowShutdownThe value of this object provides the label of the
Aux Laser Power Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.41 |
oa100bdvalueAuxLaserPowShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.42 |
oa100bdstateflagAuxLaserPowShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.43 |
oa100bdlabelADCStatusThe value of this object provides the label of the
ADC Operation Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.44 |
oa100bdvalueADCStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.45 |
oa100bdstateflagADCStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.46 |
oa100bdlabelConstGainStatusThe value of this object provides the label of the
Constant Gain Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.47 |
oa100bdvalueConstGainStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.48 |
oa100bdstateflagConstGainStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.49 |
oa100bdlabelHardwareErrorStatusThe value of this object provides the label of the
Hardware Error Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.50 |
oa100bdvalueHardwareErrorStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.51 |
oa100bdstateflagHardwareErrorStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.52 |
oa100bdlabelStandbyStatusThe value of this object provides the label of the
Standby Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.4.3.53 |
oa100bdvalueStandbyStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.54 |
oa100bdstateflagStandbyStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.17.4.3.55 |
gx2OA100BDFactoryTableThis table contains gx2OA100B specific parameters with
nominal and current values. SEQUENCE OF Gx2OA100BDFactoryEntry .1.3.6.1.4.1.1166.6.1.2.17.5 |
gx2OA100BDFactoryEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2OA100BDFactoryEntry .1.3.6.1.4.1.1166.6.1.2.17.5.4 |
gx2OA100BDFactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.5.4.1 |
oa100bdbootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.
Boot Control Byte bit definition as follows :
bit 0 : boot bit (0=boot from bank 0, 1=boot from bank 1)
bit 1 : bank 0 status (0=bank is blank/bad, 1=bank is OK)
bit 2 : bank 1 status (0=bank is blank/bad, 1=bank is OK)
bits 3-7 : not usedro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.5.4.2 |
oa100bdbootStatusByteThis object indicates the status of the last boot
Boot Status Byte bit definitions as follows:
bit 0 : bank 0 status (0=bank is OK or not used, 1=bank failed boot)
bit 1 : bank 1 status (0=bank is OK or not used, 1=bank failed boot)
bit 2 : active bank (0=bank 0 active, 1=bank 1 active)
bits 3-7: not usedro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.5.4.3 |
oa100bdbank0CRCThis object provides the CRC code of bank 0.
The value is best displayed in Hex formatro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.5.4.4 |
oa100bdbank1CRCThis object provides the CRC code of bank 1.
The value is best displayed in Hex formatro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.5.4.5 |
oa100bdprgEEPROMByteThis object indicates if the EEPROM has been programmed
programmed EEPROM byte definitions as follows:
0xBB = EEPROM is programmed
0xDB = EEPROM is being restored to factory defaults
0xFF = EEPROM is blank
any other values are assumed to be blank EEPROMro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.5.4.6 |
oa100bdfactoryCRCThis object provides the CRC code for the Factory data.
The value is best displayed in Hex formatro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.5.4.7 |
oa100bdcalculateCRCThis object indicates which of the Emnums will have the CRC calculated.
Calculate CRC command defintions as follows :
0x00 : recalculate factory data CRC
0x01 : recalcualte calibration table CRC
0x02 : recalculate alarm data CRC
other values not definedroobsolete Enumeration .1.3.6.1.4.1.1166.6.1.2.17.5.4.8 |
oa100bdhourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.5.4.9 |
oa100bdflashPrgCntAThis object provides the number of times the flash has been
programmed on side A.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.5.4.10 |
oa100bdflashPrgCntBThis object provides the number of times the flash has been
programmed on side B.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.5.4.11 |
oa100bdfwRev0This object provides the Revision of the firmware stores in bank 0.
This value should be displayed as two ascii characters.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.5.4.12 |
oa100bdfwRev1This object provides the Revision of the firmware stores in bank 1.
This value should be displayed as two ascii characters.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.17.5.4.13 |
gx2OA100BDHoldTimeTableThis table contains gx2OA100BD specific parameters with
nominal and current values. SEQUENCE OF Gx2OA100BDHoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.17.6 |
gx2OA100BDHoldTimeEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2OA100BDHoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.17.6.5 |
gx2OA100BDHoldTimeTableIndexThe value of this object is the index of the data object.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.6.5.1 |
gx2OA100BDHoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.17.6.5.2 |
gx2OA100BDHoldTimeDataThe value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds.rw INTEGER .1.3.6.1.4.1.1166.6.1.2.17.6.5.3 |