OMNI-gx2dualdrr2x-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for OMNI-gx2dualdrr2x-MIB.
318
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
318 total| Object Name |
|---|
trapdualdrrConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.1 |
trapdualdrrConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.2 |
trapdualdrr12VCurrentAlarmThis trap is issued when the 12V power supply Current
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.3 |
trapdualdrrModuleTempAlarmThis trap is issued when the Internal Module Temperature goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.4 |
trapdualdrrFanSpeedAlarmThis trap is issued when the Fan Speed
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.5 |
trapdualdrrFlashAlarmThis trap is issued when the detects an error during
Flash memory operations. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.6 |
trapdualdrrBankBootAlarmThis trap is issued when the module detects an error while booting
from bank 0 or bank 1. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.7 |
trapdualdrrAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.8 |
trapdualdrrHardwareErrAlarmThis trap is issued when hardware is abnormal. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.9 |
trapdualdrrOpticalSignal1AlarmThis trap is issued when the optical signal 1 is beyond the preset range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.10 |
trapdualdrrOpticalSignal2AlarmThis trap is issued when the optical signal 2 is beyond the preset range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.11 |
trapdualdrrFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.12 |
trapdualdrrResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.13 |
trapdualdrrTripPoint1AlarmThis trap is issued when the Input 1 optical power is lower than the custumer set
trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.14 |
trapdualdrrTripPoint2AlarmThis trap is issued when the Input 2 optical power is lower than the custumer set
trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.15 |
trapdualdrrLink1AlarmThis trap is issued when receiver 1 is out of SYN with transmitter TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.16 |
trapdualdrrLink2AlarmThis trap is issued when receiver 2 is out of SYN with transmitter TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.17 |
trapdualdrrCalibrationDataCRCAlarmThis trap is issued when the Calibration Data CRC is incorrect TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.18 |
trapdualdrrSFP1OptPWRAlarmThis trap is issued when SFP 1's optical power is incorrect TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.19 |
trapdualdrrDRT1Cur24VAlarmThis trap is issued when DRT 1's 24 volt current is incorrect TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.20 |
trapdualdrrDRT1ModTempAarmThis trap is issued when DRT 1's Module telperature is incorrect TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.21 |
trapdualdrrSFP2OptPWRAlarmThis trap is issued when SFP 2's optical power is incorrect TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.22 |
trapdualdrrDRT2Cur24VAlarmThis trap is issued when DRT 2's 24 volt current is incorrect TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.23 |
trapdualdrrDRT2ModTempAarmThis trap is issued when DRT 2's Module telperature is incorrect TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.35.0.24 |
gx2dualdrr2xDescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.35.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.35.1 |
gx2dualdrr2xAnalogTableThis table contains gx2dualdrr2x specific analog parameters with
nominal,limits and current values. SEQUENCE OF Gx2dualdrr2xAnalogEntry .1.3.6.1.4.1.1166.6.1.2.35.2 |
gx2dualdrr2xAnalogEntryThis list contains the analog parameters and descriptions. Gx2dualdrr2xAnalogEntry .1.3.6.1.4.1.1166.6.1.2.35.2.1 |
gx2dualdrr2xAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.2.1.1 |
dualdrr2xlabelRecdOptPwr1The value of this object provides the label of the
Channel 1 Received Opt power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.2 |
dualdrr2xuomRecdOptPwr1The value of this object provides the Unit of Measure of the
Channel 1 Received Opt power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.3 |
dualdrr2xmajorHighRecdOptPwr1This object is not used by this module and always returns the value of the
Channel 1 Received Opt power Major High Alarm Limit Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.4 |
dualdrr2xmajorLowRecdOptPwr1This object is not used by this module and always returns the value of the
Channel 1 Received Opt power Major High Alarm Limit Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.5 |
dualdrr2xminorHighRecdOptPwr1This object is not used by this module and always returns the value
of 10^e10 . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.6 |
dualdrr2xminorLowRecdOptPwr1This object is not used by this module and always returns the value
of 10^e10 . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.7 |
dualdrr2xcurrentValueRecdOptPwr1The value of this object provides the Current value of the
Channel 1 Received Opt power.rw Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.8 |
dualdrr2xstateFlagRecdOptPwr1The value of this object provides the state of the
Channel 1 Received Opt power Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.9 |
dualdrr2xminValueRecdOptPwr1The value of this object provides the minimum value of the
Channel 1 Received Opt power.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.10 |
dualdrr2xmaxValueRecdOptPwr1The value of this object provides the maximum value of the
Channel 1 Received Opt power.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.11 |
dualdrr2xalarmStateRecdOptPwr1The value of this object provides the curent alarm state of the
Channel 1 Received Opt power.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.12 |
dualdrr2xlabelRecdOptPwr2The value of this object provides the label of the
Channel 2 Received Opt power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.13 |
dualdrr2xuomRecdOptPwr2The value of this object provides the Unit of Measure of the
Channel 2 Received Opt power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.14 |
dualdrr2xmajorHighRecdOptPwr2This object is not used by this module and always returns the value of the
Channel 2 Received Opt power Major High Alarm Limit Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.15 |
dualdrr2xmajorLowRecdOptPwr2This object is not used by this module and always returns the value of the
Channel 2 Received Opt power Major High Alarm Limit Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.16 |
dualdrr2xminorHighRecdOptPwr2This object is not used by this module and always returns the value
of 10^e10 . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.17 |
dualdrr2xminorLowRecdOptPwr2This object is not used by this module and always returns the value
of 10^e10 . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.18 |
dualdrr2xcurrentValueRecdOptPwr2The value of this object provides the Current value of the
Channel 2 Received Opt power.rw Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.19 |
dualdrr2xstateFlagRecdOptPwr2The value of this object provides the state of the
Channel 2 Received Opt power Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.20 |
dualdrr2xminValueRecdOptPwr2The value of this object provides the minimum value of the
Channel 2 Received Opt power.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.21 |
dualdrr2xmaxValueRecdOptPwr2The value of this object provides the maximum value of the
Channel 2 Received Opt power.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.22 |
dualdrr2xalarmStateRecdOptPwr2The value of this object provides the curent alarm state of the
Channel 2 Received optical power.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.23 |
dualdrr2xlabelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.24 |
dualdrr2xuomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.25 |
dualdrr2xmajorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.26 |
dualdrr2xmajorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.27 |
dualdrr2xminorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.28 |
dualdrr2xminorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.29 |
dualdrr2xcurrentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.30 |
dualdrr2xstateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.31 |
dualdrr2xminValueModTempThe value of this object provides the minimum value
the Module Temperature Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.32 |
dualdrr2xmaxValueModTempThe value of this object provides the maximum value
the Module Temperature Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.33 |
dualdrr2xalarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.34 |
dualdrr2xlabel12VCurrentThe value of this object provides the label of the
12v power supply Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.35 |
dualdrr2xuom12VCurrentThe value of this object provides the Unit of Measure of the
12v power supply Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.36 |
dualdrr2xmajorHigh12VCurrentThe value of this object provides the Major High alarm value
of the 12v power supply Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.37 |
dualdrr2xmajorLow12VCurrentThe value of this object provides the Major Low alarm value
of the 12v power supply Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.38 |
dualdrr2xminorHigh12VCurrentThe value of this object provides the Minor High alarm value
of the 12v power supply Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.39 |
dualdrr2xminorLow12VCurrentThe value of this object provides the Minor Low alarm value
of the 12v power supply Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.40 |
dualdrr2xcurrentValue12VCurrentThe value of this object provides the Current value
of the 12v power supply Current parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.41 |
dualdrr2xstateFlag12VCurrentThe value of this object provides the state
of the 12v power supply Current Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.42 |
dualdrr2xminValue12VCurrentThe value of this object provides the minimum value
the 12v power supply Current Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.43 |
dualdrr2xmaxValue12VCurrentThe value of this object provides the maximum value
the 12v power supply Current Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.44 |
dualdrr2xalarmState12VCurrentThe value of this object provides the curent alarm state of
the 12v power supply Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.45 |
dualdrr2xlabelFanSpeedThe value of this object provides the label of the
Fan Speed Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.46 |
dualdrr2xuomFanSpeedThe value of this object provides the Unit of Measure of the
Fan Speed Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.47 |
dualdrr2xmajorHighFanSpeedThe value of this object provides the Major High alarm value
of the Fan Speed Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.48 |
dualdrr2xmajorLowFanSpeedThe value of this object provides the Major Low alarm value
of the Fan Speed Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.49 |
dualdrr2xminorHighFanSpeedThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.50 |
dualdrr2xminorLowFanSpeedThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.51 |
dualdrr2xcurrentValueFanSpeedThe value of this object provides the current value
of the Fan Speed Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.52 |
dualdrr2xstateFlagFanSpeedThe value of this object provides the state
of the Fan Speed Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.53 |
dualdrr2xminValueFanSpeedThe value of this object provides the minimum value
the Fan Speed Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.54 |
dualdrr2xmaxValueFanSpeedThe value of this object provides the maximum value
the Fan Speed Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.55 |
dualdrr2xalarmStateFanSpeedThe value of this object provides the curent alarm state of
the Fan Speed Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.56 |
dualdrr2xlabelTx0SFPWaveThe value of this object provides the label of the
Tx 0 SFP Wavelength Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.57 |
dualdrr2xuomTx0SFPWaveThe value of this object provides the Unit of Measure of the
Tx 0 SFP Wavelength Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.58 |
dualdrr2xmajorHighTx0SFPWaveThe value of this object provides the Major High alarm value
of the Tx 0 SFP Wavelength Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.59 |
dualdrr2xmajorLowTx0SFPWaveThe value of this object provides the Major Low alarm value
of the Tx 0 SFP Wavelength Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.60 |
dualdrr2xminorHighTx0SFPWaveThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.61 |
dualdrr2xminorLowTx0SFPWaveThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.62 |
dualdrr2xcurrentValueTx0SFPWaveThe value of this object provides the current value
of the Tx 0 SFP Wavelength Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.63 |
dualdrr2xstateFlagTx0SFPWaveThe value of this object provides the state
of the Tx 0 SFP Wavelength Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.64 |
dualdrr2xminValueTx0SFPWaveThe value of this object provides the minimum value
the Tx 0 SFP Wavelength Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.65 |
dualdrr2xmaxValueTx0SFPWaveThe value of this object provides the maximum value
the Tx 0 SFP Wavelength Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.66 |
dualdrr2xalarmStateTx0SFPWaveThe value of this object provides the curent alarm state of
the Tx 0 SFP Wavelength Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.67 |
dualdrr2xlabelTx0OptPwrThe value of this object provides the label of the
Tx 0 Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.68 |
dualdrr2xuomTx0OptPwrThe value of this object provides the Unit of Measure of the
Tx 0 Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.69 |
dualdrr2xmajorHighTx0OptPwrThe value of this object provides the Major High alarm value
of the Tx 0 Optical Power Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.70 |
dualdrr2xmajorLowTx0OptPwrThe value of this object provides the Major Low alarm value
of the Tx 0 Optical Power Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.71 |
dualdrr2xminorHighTx0OptPwrThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.72 |
dualdrr2xminorLowTx0OptPwrThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.73 |
dualdrr2xcurrentValueTx0OptPwrThe value of this object provides the current value
of the Tx 0 Optical Power Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.74 |
dualdrr2xstateFlagTx0OptPwrThe value of this object provides the state
of the Tx 0 Optical Power Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.75 |
dualdrr2xminValueTx0OptPwrThe value of this object provides the minimum value
the Tx 0 Optical Power Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.76 |
dualdrr2xmaxValueTx0OptPwrThe value of this object provides the maximum value
the Tx 0 Optical Power Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.77 |
dualdrr2xalarmStateTx0OptPwrThe value of this object provides the curent alarm state of
the Tx 0 Optical Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.78 |
dualdrr2xlabelTx024vCurrThe value of this object provides the label of the
Tx 0 24 Volt Current Analog parameter.ro Unknown .1.3.6.1.4.1.1166.6.1.2.35.2.1.79 |
dualdrr2xuomTx024vCurrThe value of this object provides the Unit of Measure of the
Tx 0 24 Volt Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.80 |
dualdrr2xmajorHighTx024vCurrThe value of this object provides the Major High alarm value
of the Tx 0 24 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.81 |
dualdrr2xmajorLowTx024vCurrThe value of this object provides the Major Low alarm value
of the Tx 0 24 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.82 |
dualdrr2xminorHighTx024vCurrThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.83 |
dualdrr2xminorLowTx024vCurrThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.84 |
dualdrr2xcurrentValueTx024vCurrThe value of this object provides the current value
of the Tx 0 24 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.85 |
dualdrr2xstateFlagTx024vCurrThe value of this object provides the state
of the Tx 0 24 Volt Current Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.86 |
dualdrr2xminValueTx024vCurrThe value of this object provides the minimum value
the Tx 0 24 Volt Current Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.87 |
dualdrr2xmaxValueTx024vCurrThe value of this object provides the maximum value
the Tx 0 24 Volt Current Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.88 |
dualdrr2xalarmStateTx024vCurrThe value of this object provides the curent alarm state of
the Tx 0 24 Volt Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.89 |
dualdrr2xlabelTx024VoltThe value of this object provides the label of the
Tx 0 24 Volt supply voltage Analog parameter.ro Unknown .1.3.6.1.4.1.1166.6.1.2.35.2.1.90 |
dualdrr2xuomTx024VoltThe value of this object provides the Unit of Measure of the
Tx 0 24 Volt supply voltage Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.91 |
dualdrr2xmajorHighTx024VoltThe value of this object provides the Major High alarm value
of the Tx 0 24 Volt supply voltage Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.92 |
dualdrr2xmajorLowTx024VoltThe value of this object provides the Major Low alarm value
of the Tx 0 24 Volt supply voltage Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.93 |
dualdrr2xminorHighTx024VoltThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.94 |
dualdrr2xminorLowTx024VoltThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.95 |
dualdrr2xcurrentValueTx024VoltThe value of this object provides the current value
of the Tx 0 24 Volt supply voltage Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.96 |
dualdrr2xstateFlagTx024VoltThe value of this object provides the state
of the Tx 0 24 Volt supply voltage Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.97 |
dualdrr2xminValueTx024VoltThe value of this object provides the minimum value
the Tx 0 24 Volt supply voltage Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.98 |
dualdrr2xmaxValueTx024VoltThe value of this object provides the maximum value
the Tx 0 24 Volt supply voltage Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.99 |
dualdrr2xalarmStateTx024VoltThe value of this object provides the curent alarm state of
the Tx 0 24 Volt supply voltage Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.100 |
dualdrr2xlabelTx0ModTempThe value of this object provides the label of the
Tx 0 24 Module Temperature Analog parameter.ro Unknown .1.3.6.1.4.1.1166.6.1.2.35.2.1.101 |
dualdrr2xuomTx0ModTempThe value of this object provides the Unit of Measure of the
Tx 0 Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.102 |
dualdrr2xmajorHighTx0ModTempThe value of this object provides the Major High alarm value
of the Tx 0 Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.103 |
dualdrr2xmajorLowTx0ModTempThe value of this object provides the Major Low alarm value
of the Tx 0 Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.104 |
dualdrr2xminorHighTx0ModTempThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.105 |
dualdrr2xminorLowTx0ModTempThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.106 |
dualdrr2xcurrentValueTx0ModTempThe value of this object provides the current value
of the Tx 0 Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.107 |
dualdrr2xstateFlagTx0ModTempThe value of this object provides the state
of the Tx 0 Module Temperature Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.108 |
dualdrr2xminValueTx0ModTempThe value of this object provides the minimum value
the Tx 0 Module Temperature Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.109 |
dualdrr2xmaxValueTx0ModTempThe value of this object provides the maximum value
the Tx 0 Module Temperature Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.110 |
dualdrr2xalarmStateTx0ModTempThe value of this object provides the curent alarm state of
the Tx 0 Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.111 |
dualdrr2xlabelTx1SFPWaveThe value of this object provides the label of the
Tx 1 SFP Wavelength Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.112 |
dualdrr2xuomTx1SFPWaveThe value of this object provides the Unit of Measure of the
Tx 1 SFP Wavelength Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.113 |
dualdrr2xmajorHighTx1SFPWaveThe value of this object provides the Major High alarm value
of the Tx 1 SFP Wavelength Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.114 |
dualdrr2xmajorLowTx1SFPWaveThe value of this object provides the Major Low alarm value
of the Tx 1 SFP Wavelength Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.115 |
dualdrr2xminorHighTx1SFPWaveThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.116 |
dualdrr2xminorLowTx1SFPWaveThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.117 |
dualdrr2xcurrentValueTx1SFPWaveThe value of this object provides the current value
of the Tx 1 SFP Wavelength Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.118 |
dualdrr2xstateFlagTx1SFPWaveThe value of this object provides the state
of the Tx 1 SFP Wavelength Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.119 |
dualdrr2xminValueTx1SFPWaveThe value of this object provides the minimum value
the Tx 1 SFP Wavelength Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.120 |
dualdrr2xmaxValueTx1SFPWaveThe value of this object provides the maximum value
the Tx 1 SFP Wavelength Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.121 |
dualdrr2xalarmStateTx1SFPWaveThe value of this object provides the curent alarm state of
the Tx 1 SFP Wavelength Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.122 |
dualdrr2xlabelTx1OptPwrThe value of this object provides the label of the
Tx 1 Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.123 |
dualdrr2xuomTx1OptPwrThe value of this object provides the Unit of Measure of the
Tx 1 Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.124 |
dualdrr2xmajorHighTx1OptPwrThe value of this object provides the Major High alarm value
of the Tx 1 Optical Power Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.125 |
dualdrr2xmajorLowTx1OptPwrThe value of this object provides the Major Low alarm value
of the Tx 1 Optical Power Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.126 |
dualdrr2xminorHighTx1OptPwrThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.127 |
dualdrr2xminorLowTx1OptPwrThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.128 |
dualdrr2xcurrentValueTx1OptPwrThe value of this object provides the current value
of the Tx 1 Optical Power Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.129 |
dualdrr2xstateFlagTx1OptPwrThe value of this object provides the state
of the Tx 1 Optical Power Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.130 |
dualdrr2xminValueTx1OptPwrThe value of this object provides the minimum value
the Tx 1 Optical Power Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.131 |
dualdrr2xmaxValueTx1OptPwrThe value of this object provides the maximum value
the Tx 1 Optical Power Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.132 |
dualdrr2xalarmStateTx1OptPwrThe value of this object provides the curent alarm state of
the Tx 1 Optical Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.133 |
dualdrr2xlabelTx124vCurrThe value of this object provides the label of the
Tx 1 24 VoltCurrent Analog parameter.ro Unknown .1.3.6.1.4.1.1166.6.1.2.35.2.1.134 |
dualdrr2xuomTx124vCurrThe value of this object provides the Unit of Measure of the
Tx 1 24 Volt Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.135 |
dualdrr2xmajorHighTx124vCurrThe value of this object provides the Major High alarm value
of the Tx 1 24 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.136 |
dualdrr2xmajorLowTx124vCurrThe value of this object provides the Major Low alarm value
of the Tx 1 24 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.137 |
dualdrr2xminorHighTx124vCurrThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.138 |
dualdrr2xminorLowTx124vCurrThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.139 |
dualdrr2xcurrentValueTx124vCurrThe value of this object provides the current value
of the Tx 1 24 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.140 |
dualdrr2xstateFlagTx124vCurrThe value of this object provides the state
of the Tx 1 24 Volt Current Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.141 |
dualdrr2xminValueTx124vCurrThe value of this object provides the minimum value
the Tx 1 24 Volt Current Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.142 |
dualdrr2xmaxValueTx124vCurrThe value of this object provides the maximum value
the Tx 1 24 Volt Current Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.143 |
dualdrr2xalarmStateTx124vCurrThe value of this object provides the curent alarm state of
the Tx 1 24 Volt Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.144 |
dualdrr2xlabelTx124VoltThe value of this object provides the label of the
Tx 1 24 Volt supply voltage Analog parameter.ro Unknown .1.3.6.1.4.1.1166.6.1.2.35.2.1.145 |
dualdrr2xuomTx124VoltThe value of this object provides the Unit of Measure of the
Tx 1 24 Volt supply voltage Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.146 |
dualdrr2xmajorHighTx124VoltThe value of this object provides the Major High alarm value
of the Tx 1 24 Volt supply voltage Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.147 |
dualdrr2xmajorLowTx124VoltThe value of this object provides the Major Low alarm value
of the Tx 1 24 Volt supply voltage Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.148 |
dualdrr2xminorHighTx124VoltThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.149 |
dualdrr2xminorLowTx124VoltThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.150 |
dualdrr2xcurrentValueTx124VoltThe value of this object provides the current value
of the Tx 1 24 Volt supply voltage Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.151 |
dualdrr2xstateFlagTx124VoltThe value of this object provides the state
of the Tx 1 24 Volt supply voltage Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.152 |
dualdrr2xminValueTx124VoltThe value of this object provides the minimum value
the Tx 1 24 Volt supply voltage Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.153 |
dualdrr2xmaxValueTx124VoltThe value of this object provides the maximum value
the Tx 1 24 Volt supply voltage Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.154 |
dualdrr2xalarmStateTx124VoltThe value of this object provides the curent alarm state of
the Tx 1 24 Volt supply voltage Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.155 |
dualdrr2xlabelTx1ModTempThe value of this object provides the label of the
Tx 1 24 Module Temperature Analog parameter.ro Unknown .1.3.6.1.4.1.1166.6.1.2.35.2.1.156 |
dualdrr2xuomTx1ModTempThe value of this object provides the Unit of Measure of the
Tx 1 Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.2.1.157 |
dualdrr2xmajorHighTx1ModTempThe value of this object provides the Major High alarm value
of the Tx 1 Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.158 |
dualdrr2xmajorLowTx1ModTempThe value of this object provides the Major Low alarm value
of the Tx 1 Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.159 |
dualdrr2xminorHighTx1ModTempThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.160 |
dualdrr2xminorLowTx1ModTempThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.161 |
dualdrr2xcurrentValueTx1ModTempThe value of this object provides the current value
of the Tx 1 Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.162 |
dualdrr2xstateFlagTx1ModTempThe value of this object provides the state
of the Tx 1 Module Temperature Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.163 |
dualdrr2xminValueTx1ModTempThe value of this object provides the minimum value
the Tx 1 Module Temperature Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.164 |
dualdrr2xmaxValueTx1ModTempThe value of this object provides the maximum value
the Tx 1 Module Temperature Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.35.2.1.165 |
dualdrr2xalarmStateTx1ModTempThe value of this object provides the curent alarm state of
the Tx 1 Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.2.1.166 |
gx2dualdrr2xDigitalTableThis table contains gx2dualdrr2x specific digital parameters with
nominal and current values. SEQUENCE OF Gx2dualdrr2xDigitalEntry .1.3.6.1.4.1.1166.6.1.2.35.3 |
gx2dualdrr2xDigitalEntryThis list contains individual digital parameters and descriptions. Gx2dualdrr2xDigitalEntry .1.3.6.1.4.1.1166.6.1.2.35.3.2 |
gx2dualdrr2xDigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.3.2.1 |
dualdrr2xlabelTrippoint1ValueThe value of this object provides the label of the
Trip point Value Digital parameter. The trip point Value defines the RF switch
point based on the optical power input to the DRRro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.2 |
dualdrr2xenumTrippoint1ValueThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.3 |
dualdrr2xvalueTrippoint1ValueThe value of this object reflects the setting of the threshold at
which the Trip point activates. It is in 1 dB increments
ranging from -25 to -5 dB. The user can enter a number from 0 to 20,
where 0 = -5db and 19 = -25dbrw INTEGER .1.3.6.1.4.1.1166.6.1.2.35.3.2.4 |
dualdrr2xstateflagTrippoint1ValueThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.5 |
dualdrr2xlabelTrippoint1ModeThe value of this object provides the label of the
Trip point mode Digital parameter. The trip point mode defines the RF switch
action based on the optical power input to the DRRro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.6 |
dualdrr2xenumTrippoint1ModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.7 |
dualdrr2xvalueTrippoint1ModeThe value of this object is the current value of trip point mode.
There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch.
If module input optical power is higher than the preset trippoint value,
no operational difference for these three modes.
If module input optical power is less than the preset trippoint value,
1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance
will stay normal as low.
2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power
lower than the preset trippoint level but RF output impedance will stay normal as low.
3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance
will switch to abnormlrw Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.8 |
dualdrr2xstateflagTrippoint1ModeThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.9 |
dualdrr2xlabelTrippoint2ValueThe value of this object provides the label of the
Trip point Value Digital parameter. The trip point Value defines the RF switch
point based on the optical power input to the DRRro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.10 |
dualdrr2xenumTrippoint2ValueThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.11 |
dualdrr2xvalueTrippoint2ValueThe value of this object reflects the setting of the threshold at
which the Trip point activates. It is in 1 dB increments
ranging from -25 to -5 dB. The user can enter a number from 0 to 20,
where 0 = -5db and 19 = -25dbrw INTEGER .1.3.6.1.4.1.1166.6.1.2.35.3.2.12 |
dualdrr2xstateflagTrippoint2ValueThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.13 |
dualdrr2xlabelTrippoint2ModeThe value of this object provides the label of the
Trip point mode Digital parameter. The trip point mode defines the RF switch
action based on the optical power input to the DRRro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.14 |
dualdrr2xenumTrippoint2ModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.15 |
dualdrr2xvalueTrippoint2ModeThe value of this object is the current value of trip point mode.
There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch.
If module input optical power is higher than the preset trippoint value,
no operational difference for these three modes.
If module input optical power is less than the preset trippoint value,
1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance
will stay normal as low.
2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power
lower than the preset trippoint level but RF output impedance will stay normal as low.
3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance
will switch to abnormlrw Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.16 |
dualdrr2xstateflagTrippoint2ModeThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.17 |
dualdrr2xlabelGainChannel1AThe value of this object provides the label of the
RF Channel 1A Gain Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.18 |
dualdrr2xenumGainChannel1AThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.19 |
dualdrr2xvalueGainChannel1AThe value of this object reflects the setting of the gain for
RF Channel 1A. It is in 1 dB increments
ranging from 0 to 20dB. The user can enter a number from 0 to 20rw INTEGER .1.3.6.1.4.1.1166.6.1.2.35.3.2.20 |
dualdrr2xstateflagGainChannel1AThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.21 |
dualdrr2xlabelGainChannel1BThe value of this object provides the label of the
RF Channel 1B Gain Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.22 |
dualdrr2xenumGainChannel1BThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.23 |
dualdrr2xvalueGainChannel1BThe value of this object reflects the setting of the gain for
RF Channel 1B. It is in 1 dB increments
ranging from 0 to 20dB. The user can enter a number from 0 to 20rw INTEGER .1.3.6.1.4.1.1166.6.1.2.35.3.2.24 |
dualdrr2xstateflagGainChannel1BThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.25 |
dualdrr2xlabelGainChannel2AThe value of this object provides the label of the
RF Channel 2A Gain Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.26 |
dualdrr2xenumGainChannel2AThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.27 |
dualdrr2xvalueGainChannel2AThe value of this object reflects the setting of the gain for
RF Channel 2A. It is in 1 dB increments
ranging from 0 to 20dB. The user can enter a number from 0 to 20rw INTEGER .1.3.6.1.4.1.1166.6.1.2.35.3.2.28 |
dualdrr2xstateflagGainChannel2AThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.29 |
dualdrr2xlabelGainChannel2BThe value of this object provides the label of the
RF Channel 2B Gain Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.30 |
dualdrr2xenumGainChannel2BThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.31 |
dualdrr2xvalueGainChannel2BThe value of this object reflects the setting of the gain for
RF Channel 2B. It is in 1 dB increments
ranging from 0 to 20dB. The user can enter a number from 0 to 20rw INTEGER .1.3.6.1.4.1.1166.6.1.2.35.3.2.32 |
dualdrr2xstateflagGainChannel2BThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.33 |
dualdrr2xlabelTestpointSelectThe value of this object provides the label of the
Module's test point select Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.34 |
dualdrr2xenumTestpointSelectThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.35 |
dualdrr2xvalueTestpointSelectThe value of this object reflects the setting of the test point selector for
The Module. The user can enter a number from 1 to 4rw Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.36 |
dualdrr2xstateflagTestpointSelectThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.37 |
dualdrr2xlabelOpFrequencyThe value of this object provides the label of the
Module's active channels Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.38 |
dualdrr2xenumOpFrequencyThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.39 |
dualdrr2xvalueOpFrequencyThe value of this object reflects which channels are active for
The Module. The user can enter a number from 1 to 4rw Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.40 |
dualdrr2xstateflagOpFrequencyThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.41 |
dualdrr2xlabelActChanSelectThe value of this object provides the label of the
Module's active channels Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.42 |
dualdrr2xenumActChanSelectThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.43 |
dualdrr2xvalueActChanSelectThe value of this object reflects which channels are active for
The Module. The user can enter a number from 1 to 4rw Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.44 |
dualdrr2xstateflagActChanSelectThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.45 |
dualdrr2xlabelFactoryDefaultResetThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.46 |
dualdrr2xenumFactoryDefaultResetThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.3.2.47 |
dualdrr2xvalueFactoryDefaultResetThe read of this value will return a invalid value.
The read will not reflect the actual setting value for this parameterrw Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.48 |
dualdrr2xstateflagFactoryDefaultResetThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.3.2.49 |
gx2dualdrr2xStatusTableThis table contains gx2dualdrr2x specific status parameters with
nominal and current values. SEQUENCE OF Gx2dualdrr2xStatusEntry .1.3.6.1.4.1.1166.6.1.2.35.4 |
gx2dualdrr2xStatusEntryThis list contains Status parameters and descriptions. Gx2dualdrr2xStatusEntry .1.3.6.1.4.1.1166.6.1.2.35.4.3 |
gx2dualdrr2xStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.4.3.1 |
dualdrr2xlabelBootThe value of this object provides the label of the
Boot Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.2 |
dualdrr2xvalueBootThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.3 |
dualdrr2xstateflagBootThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.4 |
dualdrr2xlabelFlashThe value of this object provides the label of the
Flash Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.5 |
dualdrr2xvalueFlashThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.6 |
dualdrr2xstateflagFlashThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.7 |
dualdrr2xlabelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.8 |
dualdrr2xvalueFactoryDataCRCThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.9 |
dualdrr2xstateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.10 |
dualdrr2xlabelAlarmDataCrcThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.11 |
dualdrr2xvalueAlarmDataCrcThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.12 |
dualdrr2xstateflagAlarmDataCrcThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.13 |
dualdrr2xlabelCalibrationDataCrcThe value of this object provides the label of the
Calibration Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.14 |
dualdrr2xvalueCalibrationDataCrcThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.15 |
dualdrr2xstateflagCalibrationDataCrcThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.16 |
dualdrr2xlabelHardwareStatusThe value of this object provides the label of the
Module Hardware Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.17 |
dualdrr2xvalueHardwareStatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.18 |
dualdrr2xstateflagHardwareStatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.19 |
dualdrr2xlabelCh1TripPointStatusThe value of this object provides the label of the
Optical Trip Point Status parameter.It indicates whether
the optical power is above(0) or below(1) trip point valuero DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.20 |
dualdrr2xvalueCh1TripPointStatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.21 |
dualdrr2xstateflagCh1TripPointStatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.22 |
dualdrr2xlabelLink1StatusThe value of this object provides the label of the
Link Activity Status parameter. It represents receiver
out of SYN with transmitter or Demux can not detect
the optical signal.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.23 |
dualdrr2xvalueLink1StatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.24 |
dualdrr2xstateflagLink1StatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.25 |
dualdrr2xlabelCh2TripPointStatusThe value of this object provides the label of the
Optical Trip Point Status parameter.It indicates whether
the optical power is above(0) or below(1) trip point valuero DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.26 |
dualdrr2xvalueCh2TripPointStatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.27 |
dualdrr2xstateflagCh2TripPointStatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.28 |
dualdrr2xlabelLink2StatusThe value of this object provides the label of the
Link Activity Status parameter. It represents receiver
out of SYN with transmitter or Demux can not detect
the optical signal.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.29 |
dualdrr2xvalueLink2StatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.30 |
dualdrr2xstateflagLink2StatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.31 |
dualdrr2xlabelDRT1StatusThe value of this object provides the label of the
Link Activity Status parameter. It represents receiver
out of SYN with transmitter or Demux can not detect
the optical signal.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.32 |
dualdrr2xvalueDRT1StatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.33 |
dualdrr2xstateflagDRT1StatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.34 |
dualdrr2xlabelSFP0StatusThe value of this object provides the label of the
Link Activity Status parameter. It represents receiver
out of SYN with transmitter or Demux can not detect
the optical signal.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.35 |
dualdrr2xvalueSFP0StatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.36 |
dualdrr2xstateflagSFP0StatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.37 |
dualdrr2xlabelDRT2StatusThe value of this object provides the label of the
Link Activity Status parameter. It represents receiver
out of SYN with transmitter or Demux can not detect
the optical signal.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.38 |
dualdrr2xvalueDRT2StatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.39 |
dualdrr2xstateflagDRT2StatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.40 |
dualdrr2xlabelSFP1StatusThe value of this object provides the label of the
Link Activity Status parameter. It represents receiver
out of SYN with transmitter or Demux can not detect
the optical signal.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.4.3.41 |
dualdrr2xvalueSFP1StatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.42 |
dualdrr2xstateflagSFP1StatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.4.3.43 |
gx2dualdrr2xFactoryTableThis table contains gx2dualdrr2x specific factory setting parameters with
nominal and current values. SEQUENCE OF Gx2dualdrr2xFactoryEntry .1.3.6.1.4.1.1166.6.1.2.35.5 |
gx2dualdrr2xFactoryEntryThis list contains Factory setting parameters and descriptions. Gx2dualdrr2xFactoryEntry .1.3.6.1.4.1.1166.6.1.2.35.5.4 |
gx2dualdrr2xFactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.5.4.1 |
dualdrr2xbootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.5.4.2 |
dualdrr2xbootStatusByteThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.5.4.3 |
dualdrr2xbank1CRCThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.5.4.4 |
dualdrr2xbank2CRCThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.5.4.5 |
dualdrr2xprgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.5.4.6 |
dualdrr2xfactoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.5.4.7 |
dualdrr2xcalculateCRCThis object indicates which of the Emnums will have the
CRC calculated (1-factory, 2-alarm, 3-calibration).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.35.5.4.8 |
dualdrr2xhourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.5.4.9 |
dualdrr2xflashPrgCntAThis object provides the number of times Bank 0 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.5.4.10 |
dualdrr2xflashPrgCntBThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.35.5.4.11 |
dualdrr2xflashBankARevThis object provides the revision of flash bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.12 |
dualdrr2xflashBankBRevThis object provides the revision of flash bank 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.13 |
dualdrr2xSubAgentRevThis object provides the subagent revision of receiver module.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.14 |
dualdrr2xFPGA0FwRevThis object provides the Firmware revision of the first DRR FPGA.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.15 |
dualdrr2xFPGA1FwRevThis object provides the Firmware revision of the second DRR FPGA.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.16 |
dualdrr2xDRT1SerialNoThis object provides the Serial Number of the DRT attached to channel 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.17 |
dualdrr2xDRT1SFPSerialNoThis object provides the Serial Number of the SFP in the DRT attached to channel 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.18 |
dualdrr2xDRT1SFPPartNoThis object provides the Part number of the SFP in the DRT attached to channel 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.19 |
dualdrr2xDRT1FwRevThis object provides the Firmware revision of the DRT attached to channel 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.20 |
dualdrr2xDRT1FpgaFwRevThis object provides the Firmware revision of the FPGA in the DRT attached to channel 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.21 |
dualdrr2xDRT2SerialNoThis object provides the Serial Number of the DRT attached to channel 2ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.22 |
dualdrr2xDRT2SFPSerialNoThis object provides the Serial Number of the SFP in the DRT attached to channel 2ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.23 |
dualdrr2xDRT2SFPPartNoThis object provides the Part number of the SFP in the DRT attached to channel 2.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.24 |
dualdrr2xDRT2FwRevThis object provides the Firmware revision of the DRT attached to channel 2.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.25 |
dualdrr2xDRT2FpgaFwRevThis object provides the Firmware revision of the FPGA in the DRT attached to channel 2.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.35.5.4.26 |