OMNI-gx2EDFA-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for OMNI-gx2EDFA-MIB.
272
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
272 total| Object Name |
|---|
trapEDFAConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.1 |
trapEDFAConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.2 |
trapEDFAModuleTemperatureAlarmThis trap is issued when the EDFA Module's Temperature goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.3 |
trapEDFAOpticalInPowerAlarmThis trap is issued when the input Optical Input Power parameter
goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.4 |
trapEDFAOpticalOutPowerAlarmThis trap is issued when the input Optical Output Power parameter
goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.5 |
trapEDFATECTemperatureAlarmThis trap is issued when the EDFA TEC Temperature goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.6 |
trapEDFATECCurrentAlarmThis trap is issued when the EDFA TEC Current goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.7 |
trapEDFALaserCurrentAlarmThis trap is issued when the EDFA Laser Current goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.8 |
trapEDFALaserPowerAlarmThis trap is issued when the EDFA Laser Power goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.9 |
trapEDFAPlus12CurrentAlarmThis trap is issued when the EDFA 12 volt current parameter
goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.10 |
trapEDFAPlus37CurrentAlarmThis trap is issued when the EDFA 3.7 volt current parameter
goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.11 |
trapEDFAFanCurrentAlarmThis trap is issued when the EDFA Module's Fan Currrent parameter
goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.12 |
trapEDFAResetFacDefaultThis trap is issued when the EDFA resets to factory defaults TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.13 |
trapEDFAStandbyModeThis trap is issued when the EDFA is in Standby Mode. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.14 |
trapEDFAOptInShutdownThis trap is issued when the EDFA is in Optical Input Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.15 |
trapEDFATECTempShutdownThis trap is issued when the EDFA is in TEC Temperature Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.16 |
trapEDFAKeySwitchThis trap is issued when the Key Switch disables the EDFA. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.17 |
trapEDFAPowerFailThis trap is issued when there is an EDFA Power Supply Failure. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.18 |
trapEDFALasCurrShutdownThis trap is issued when the EDFA is in Laser Current Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.19 |
trapEDFALasPowerShutdownThis trap is issued when the EDFA is in Laser Power Shutdown. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.20 |
trapEDFAInvalidModeThis trap is issued when the EDFA is in an invalid mode. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.21 |
trapEDFAFlashAlarmThis trap is issued when the EDFA Module's boot or flash programming sequence has
detected a Flash error. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.22 |
trapEDFABoot0AlarmThis trap is issued when the EDFA Module's Bank 0 Boot sequence has detected an error. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.23 |
trapEDFABoot1AlarmThis trap is issued when the EDFA Module's Bank 1 Boot sequence has detected an error. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.24 |
trapEDFAAlarmDataCRCAlarmThis trap is issued when the EDFA Module detects an error calculating the alarm limit CRC. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.25 |
trapEDFAFactoryDataCRCAlarmThis trap is issued when the EDFA Module detects an error calculating the Factory data CRC. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.26 |
trapEDFACalDataCRCAlarmThis trap is issued when the EDFA Module detects an error calculating the Calibration data CRC. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.27 |
trapEDFAFacCalFloatAlarmThis trap is issued when the EDFA Module detects factory calibration float data alarm. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.28 |
trapEDFAOptInThreshAlarmThis trap is issued when the EDFA Module Optical Input drops below the user set threshold. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.29 |
trapEDFAGainErrorAlarmThis trap is issued when the EDFA Module cannot produce the desired user set gain in Constant Gain Set Mode. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.11.0.30 |
gx2EDFADescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.11.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.11.1 |
gx2EDFAAnalogTableThis table contains gx2EDFA specific parameters with
nominal and current values. SEQUENCE OF Gx2EDFAAnalogEntry .1.3.6.1.4.1.1166.6.1.2.11.2 |
gx2EDFAAnalogEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2EDFAAnalogEntry .1.3.6.1.4.1.1166.6.1.2.11.2.1 |
edfagx2EDFAAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.2.1.1 |
edfalabelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.2 |
edfauomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.3 |
edfamajorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.4 |
edfamajorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.5 |
edfaminorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.6 |
edfaminorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.7 |
edfacurrentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.8 |
edfastateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.9 |
edfaminValueModTempThe value of this object provides the minimum value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.10 |
edfamaxValueModTempThe value of this object provides the maximum value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.11 |
edfaalarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.12 |
edfalabelOptInPowerThe value of this object provides the label of the
Optical Input Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.13 |
edfauomOptInPowerThe value of this object provides the Unit of Measure of the
Optical Input Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.14 |
edfamajorHighOptInPowerThe value of this object provides the Major High alarm value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.15 |
edfamajorLowOptInPowerThe value of this object provides the Major Low alarm value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.16 |
edfaminorHighOptInPowerThe value of this object provides the Minor High alarm value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.17 |
edfaminorLowOptInPowerThe value of this object provides the Minor Low alarm value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.18 |
edfacurrentValueOptInPowerThe value of this object provides the Current value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.19 |
edfastateFlagOptInPowerThe value of this object provides the state
of the Optical Input Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.20 |
edfaminValueOptInPowerThe value of this object provides the minimum value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.21 |
edfamaxValueOptInPowerThe value of this object provides the maximum value
of the Optical Input Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.22 |
edfaalarmStateOptInPowerThe value of this object provides the curent alarm state of
the Optical Input Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.23 |
edfalabelOptOutPowerThe value of this object provides the label of the
Optical Output Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.24 |
edfauomOptOutPowerThe value of this object provides the Unit of Measure of the
Optical Output Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.25 |
edfamajorHighOptOutPowerThe value of this object provides the Major High alarm value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.26 |
edfamajorLowOptOutPowerThe value of this object provides the Major Low alarm value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.27 |
edfaminorHighOptOutPowerThe value of this object provides the Minor High alarm value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.28 |
edfaminorLowOptOutPowerThe value of this object provides the Minor Low alarm value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.29 |
edfacurrentValueOptOutPowerThe value of this object provides the Current value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.30 |
edfastateFlagOptOutPowerThe value of this object provides the state
of the Optical Output Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.31 |
edfaminValueOptOutPowerThe value of this object provides the minimum value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.32 |
edfamaxValueOptOutPowerThe value of this object provides the maximum value
of the Optical Output Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.33 |
edfaalarmStateOptOutPowerThe value of this object provides the curent alarm state of
the Optical Output Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.34 |
edfalabelTECTempThe value of this object provides the label of the
TEC Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.35 |
edfauomTECTempThe value of this object provides the Unit of Measure of the
TEC Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.36 |
edfamajorHighTECTempThe value of this object provides the Major High alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.37 |
edfamajorLowTECTempThe value of this object provides the Major Low alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.38 |
edfaminorHighTECTempThe value of this object provides the Minor High alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.39 |
edfaminorLowTECTempThe value of this object provides the Minor Low alarm value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.40 |
edfacurrentValueTECTempThe value of this object provides the Current value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.41 |
edfastateFlagTECTempThe value of this object provides the state
of the TEC Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.42 |
edfaminValueTECTempThe value of this object provides the minimum value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.43 |
edfamaxValueTECTempThe value of this object provides the maximum value
of the TEC Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.44 |
edfaalarmStateTECTempThe value of this object provides the curent alarm state of
the TEC Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.45 |
edfalabelTECCurrentThe value of this object provides the label of the
TEC Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.46 |
edfauomTECCurrentThe value of this object provides the Unit of Measure of the
TEC Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.47 |
edfamajorHighTECCurrentThe value of this object provides the Major High alarm value
of the TEC Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.48 |
edfamajorLowTECCurrentThe value of this object provides the Major Low alarm value
of the TEC Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.49 |
edfaminorHighTECCurrentThe value of this object provides the Minor High alarm value
of the TEC Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.50 |
edfaminorLowTECCurrentThe value of this object provides the Minor Low alarm value
of the TEC Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.51 |
edfacurrentValueTECCurrentThe value of this object provides the Current value
of the TEC Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.52 |
edfastateFlagTECCurrentThe value of this object provides the state
of the TEC Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.53 |
edfaminValueTECCurrentThe value of this object provides the minimum value
of the TEC Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.54 |
edfamaxValueTECCurrentThe value of this object provides the maximum value
of the TEC Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.55 |
edfaalarmStateTECCurrentThe value of this object provides the curent alarm state of
the TEC Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.56 |
edfalabelLaserCurrentThe value of this object provides the label of the
Laser Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.57 |
edfauomLaserCurrentThe value of this object provides the Unit of Measure of the
Laser Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.58 |
edfamajorHighLaserCurrentThe value of this object provides the Major High alarm value
of the Laser Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.59 |
edfamajorLowLaserCurrentThe value of this object provides the Major Low alarm value
of the Laser Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.60 |
edfaminorHighLaserCurrentThe value of this object provides the Minor High alarm value
of the Laser Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.61 |
edfaminorLowLaserCurrentThe value of this object provides the Minor Low alarm value
of the Laser Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.62 |
edfacurrentValueLaserCurrentThe value of this object provides the Current value
of the Laser Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.63 |
edfastateFlagLaserCurrentThe value of this object provides the state
of the Laser Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.64 |
edfaminValueLaserCurrentThe value of this object provides the minimum value
of the Laser Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.65 |
edfamaxValueLaserCurrentThe value of this object provides the maximum value
of the Laser Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.66 |
edfaalarmStateLaserCurrentThe value of this object provides the curent alarm state of
the Laser Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.67 |
edfalabelLaserPowerThe value of this object provides the label of the
Laser Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.68 |
edfauomLaserPowerThe value of this object provides the Unit of Measure of the
Laser Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.69 |
edfamajorHighLaserPowerThe value of this object provides the Major High alarm value
of the Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.70 |
edfamajorLowLaserPowerThe value of this object provides the Major Low alarm value
of the Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.71 |
edfaminorHighLaserPowerThe value of this object provides the Minor High alarm value
of the Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.72 |
edfaminorLowLaserPowerThe value of this object provides the Minor Low alarm value
of the Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.73 |
edfacurrentValueLaserPowerThe value of this object provides the Current value
of the Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.74 |
edfastateFlagLaserPowerThe value of this object provides the state
of the Laser Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.75 |
edfaminValueLaserPowerThe value of this object provides the minimum value
of the Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.76 |
edfamaxValueLaserPowerThe value of this object provides the maximum value
of the Laser Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.77 |
edfaalarmStateLaserPowerThe value of this object provides the curent alarm state of
the Laser Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.78 |
edfalabel12VoltThe value of this object provides the label of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.79 |
edfauom12VoltThe value of this object provides the Unit of Measure of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.80 |
edfamajorHigh12VoltThe value of this object provides the Major High alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.81 |
edfamajorLow12VoltThe value of this object provides the Major Low alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.82 |
edfaminorHigh12VoltThe value of this object provides the Minor High alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.83 |
edfaminorLow12VoltThe value of this object provides the Minor Low alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.84 |
edfacurrentValue12VoltThe value of this object provides the Current value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.85 |
edfastateFlag12VoltThe value of this object provides the state
of the 12v Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.86 |
edfaminValue12VoltThe value of this object provides the minimum value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.87 |
edfamaxValue12VoltThe value of this object provides the maximum value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.88 |
edfaalarmState12VoltThe value of this object provides the curent alarm state of
the 12v Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.89 |
edfalabel37VoltThe value of this object provides the label of the
3.7v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.90 |
edfauom37VoltThe value of this object provides the Unit of Measure of the
3.7v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.91 |
edfamajorHigh37VoltThe value of this object provides the Major High alarm value
of the 3.7 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.92 |
edfamajorLow37VoltThe value of this object provides the Major Low alarm value
of the 3.7 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.93 |
edfaminorHigh37VoltThe value of this object provides the Minor High alarm value
of the 3.7 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.94 |
edfaminorLow37VoltThe value of this object provides the Minor Low alarm value
of the 3.7 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.95 |
edfacurrentValue37VoltThe value of this object provides the Current value
of the 3.7 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.96 |
edfastateFlag37VoltThe value of this object provides the state
of the 3.7v Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.97 |
edfaminValue37VoltThe value of this object provides the minimum value
of the 3.7 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.98 |
edfamaxValue37VoltThe value of this object provides the maximum value
of the 3.7 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.99 |
edfaalarmState37VoltThe value of this object provides the curent alarm state of
the 3.7v Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.100 |
edfalabelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.101 |
edfauomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.102 |
edfamajorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.103 |
edfamajorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.104 |
edfaminorHighFanCurrentThe value of this object provides the Minor High alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.105 |
edfaminorLowFanCurrentThe value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.106 |
edfacurrentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.107 |
edfastateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.108 |
edfaminValueFanCurrentThe value of this object provides the minimum value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.109 |
edfamaxValueFanCurrentThe value of this object provides the maximum value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.110 |
edfaalarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.111 |
edfalabelOPSettingThe value of this object provides the label of the
Output Power Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.112 |
edfauomOPSettingThe value of this object provides the Unit of Measure of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.113 |
edfamajorHighOPSettingThe value of this object provides the Major High alarm value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.114 |
edfamajorLowOPSettingThe value of this object provides the Major Low alarm value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.115 |
edfaminorHighOPSettingThe value of this object provides the Minor High alarm value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.116 |
edfaminorLowOPSettingThe value of this object provides the Minor Low alarm value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.117 |
edfacurrentValueOPSettingThe value of this object provides the Current value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.118 |
edfastateFlagOPSettingThe value of this object provides the state
of the Output Power Setting Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.119 |
edfaminValueOPSettingThe value of this object provides the minimum value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.120 |
edfamaxValueOPSettingThe value of this object provides the maximum value
of the Output Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.121 |
edfaalarmStateOPSettingThe value of this object provides the curent alarm state of
the Output Power Setting Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.122 |
edfalabelLPSettingThe value of this object provides the label of the
Laser Power Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.123 |
edfauomLPSettingThe value of this object provides the Unit of Measure of the
Laser Power Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.124 |
edfamajorHighLPSettingThe value of this object provides the Major High alarm value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.125 |
edfamajorLowLPSettingThe value of this object provides the Major Low alarm value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.126 |
edfaminorHighLPSettingThe value of this object provides the Minor High alarm value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.127 |
edfaminorLowLPSettingThe value of this object provides the Minor Low alarm value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.128 |
edfacurrentValueLPSettingThe value of this object provides the Current value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.129 |
edfastateFlagLPSettingThe value of this object provides the state
of the Laser Power Setting Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.130 |
edfaminValueLPSettingThe value of this object provides the minimum value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.131 |
edfamaxValueLPSettingThe value of this object provides the maximum value
of the Laser Power Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.132 |
edfaalarmStateLPSettingThe value of this object provides the curent alarm state of
the Laser Power Setting Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.133 |
edfalabelCGSettingThe value of this object provides the label of the
Constant Gain Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.134 |
edfauomCGSettingThe value of this object provides the Unit of Measure of the
Constant Gain Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.135 |
edfamajorHighCGSettingThe value of this object provides the Major High alarm value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.136 |
edfamajorLowCGSettingThe value of this object provides the Major Low alarm value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.137 |
edfaminorHighCGSettingThe value of this object provides the Minor High alarm value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.138 |
edfaminorLowCGSettingThe value of this object provides the Minor Low alarm value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.139 |
edfacurrentValueCGSettingThe value of this object provides the Current value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.140 |
edfastateFlagCGSettingThe value of this object provides the state
of the Constant Gain Setting Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.141 |
edfaminValueCGSettingThe value of this object provides the minimum value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.142 |
edfamaxValueCGSettingThe value of this object provides the maximum value
of the Constant Gain Setting Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.143 |
edfaalarmStateCGSettingThe value of this object provides the curent alarm state of
the Constant Gain Setting Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.144 |
edfalabelOptThresholdThe value of this object provides the label of the
Optical Input Threshold Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.145 |
edfauomOptThresholdThe value of this object provides the Unit of Measure of the
Optical Input Threshold Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.2.1.146 |
edfamajorHighOptThresholdThe value of this object provides the Major High alarm value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.147 |
edfamajorLowOptThresholdThe value of this object provides the Major Low alarm value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.148 |
edfaminorHighOptThresholdThe value of this object provides the Minor High alarm value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.149 |
edfaminorLowOptThresholdThe value of this object provides the Minor Low alarm value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.150 |
edfacurrentValueOptThresholdThe value of this object provides the Current value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.151 |
edfastateFlagOptThresholdThe value of this object provides the state
of the Optical Input Threshold Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.152 |
edfaminValueOptThresholdThe value of this object provides the minimum value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.153 |
edfamaxValueOptThresholdThe value of this object provides the maximum value
of the Optical Input Threshold Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.11.2.1.154 |
edfaalarmStateOptThresholdThe value of this object provides the curent alarm state of
the Optical Input Threshold Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.2.1.155 |
gx2EDFADigitalTableThis table contains gx2EDFA specific parameters with
nominal and current values. SEQUENCE OF Gx2EDFADigitalEntry .1.3.6.1.4.1.1166.6.1.2.11.3 |
gx2EDFADigitalEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2EDFADigitalEntry .1.3.6.1.4.1.1166.6.1.2.11.3.2 |
edfagx2EDFADigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.3.2.1 |
edfalabelModeSettingThe value of this object provides the label of the
EDFA's Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.3.2.2 |
edfaenumModeSettingThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.3.2.3 |
edfavalueModeSettingThe value of this object is the current value of the parameter. It is an integer
value from 0 to 5 representing the operation mode of the module.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.11.3.2.4 |
edfastateFlagModeSettingThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.3.2.5 |
edfalabelModuleStateThe value of this object provides the label of the
Module State Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.3.2.6 |
edfaenumModuleStateThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.3.2.7 |
edfavalueModuleStateThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.11.3.2.8 |
edfastateFlagModuleStateThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.3.2.9 |
edfalabelFactoryDefaultThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.3.2.10 |
edfaenumFactoryDefaultThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.3.2.11 |
edfavalueFactoryDefaultThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.11.3.2.12 |
edfastateFlagFactoryDefaultThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.3.2.13 |
gx2EDFAStatusTableThis table contains gx2EDFA specific parameters with
nominal and current values. SEQUENCE OF Gx2EDFAStatusEntry .1.3.6.1.4.1.1166.6.1.2.11.4 |
gx2EDFAStatusEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2EDFAStatusEntry .1.3.6.1.4.1.1166.6.1.2.11.4.3 |
edfagx2EDFAStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.4.3.1 |
edfalabelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.2 |
edfavalueBootThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.3 |
edfastateflagBootThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.4 |
edfalabelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.5 |
edfavalueFlashThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.6 |
edfastateflagFlashThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.7 |
edfalabelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.8 |
edfavalueFactoryDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.9 |
edfastateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.10 |
edfalabelAlarmDataCRCThe value of this object provides the label of the
Alarm Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.11 |
edfavalueAlarmDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.12 |
edfastateflagAlarmDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.13 |
edfalabelCalibrationDataCRCThe value of this object provides the label of the
Calibration Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.14 |
edfavalueCalibrationDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.15 |
edfastateflagCalibrationDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.16 |
edfalabelOptInShutdownThe value of this object provides the label of the
Optical Input Power Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.17 |
edfavalueOptInShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.18 |
edfastateflagOptInShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.19 |
edfalabelTECTempShutdownThe value of this object provides the label of the
TEC Temperature Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.20 |
edfavalueTECTempShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.21 |
edfastateflagTECTempShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.22 |
edfalabelTECShutOverrideThe value of this object provides the label of the
TEC Shutdown Override Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.23 |
edfavalueTECShutOverrideThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.24 |
edfastateflagTECShutOverrideThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.25 |
edfalabelPowerFailThe value of this object provides the label of the
Power Supply Fail Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.26 |
edfavaluePowerFailThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.27 |
edfastateflagPowerFailThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.28 |
edfalabelKeySwitchThe value of this object provides the label of the
Key Switch Setting Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.29 |
edfavalueKeySwitchThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.30 |
edfastateflagKeySwitchThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.31 |
edfalabelLaserCurrShutdownThe value of this object provides the label of the
Laser Current Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.32 |
edfavalueLaserCurrShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.33 |
edfastateflagLaserCurrShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.34 |
edfalabelLaserPowShutdownThe value of this object provides the label of the
Laser Power Shutdown Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.35 |
edfavalueLaserPowShutdownThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.36 |
edfastateflagLaserPowShutdownThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.37 |
edfalabelADCStatusThe value of this object provides the label of the
ADC Operation Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.38 |
edfavalueADCStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.39 |
edfastateflagADCStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.40 |
edfalabelConstGainStatusThe value of this object provides the label of the
Constant Gain Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.41 |
edfavalueConstGainStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.42 |
edfastateflagConstGainStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.43 |
edfalabelStandbyStatusThe value of this object provides the label of the
Standby Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.4.3.44 |
edfavalueStandbyStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.45 |
edfastateflagStandbyStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.4.3.46 |
gx2EDFAFactoryTableThis table contains gx2EDFA specific parameters with
nominal and current values. SEQUENCE OF Gx2EDFAFactoryEntry .1.3.6.1.4.1.1166.6.1.2.11.5 |
gx2EDFAFactoryEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2EDFAFactoryEntry .1.3.6.1.4.1.1166.6.1.2.11.5.4 |
edfagx2EDFAFactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.5.4.1 |
edfabootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.5.4.2 |
edfabootStatusByteThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.5.4.3 |
edfabank0CRCThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.5.4.4 |
edfabank1CRCThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.5.4.5 |
edfaprgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.5.4.6 |
edfafactoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.5.4.7 |
edfacalculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.11.5.4.8 |
edfahourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.5.4.9 |
edfaflashPrgCntAThis object provides the number of times the flash has been
programmed on side A.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.5.4.10 |
edfaflashPrgCntBThis object provides the number of times the flash has been
programmed on side B.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.5.4.11 |
edfafwRev0This object provides the Revision of the firmware stores in bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.5.4.12 |
edfafwRev1This object provides the Revision of the firmware stores in bank 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.11.5.4.13 |
gx2EDFAHoldTimeTableThis table contains gx2EDFA specific parameters with
nominal and current values. SEQUENCE OF Gx2EDFAHoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.11.6 |
gx2EDFAHoldTimeEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2EDFAHoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.11.6.5 |
gx2EDFAHoldTimeTableIndexThe value of this object is the index of the data object.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.6.5.1 |
gx2EDFAHoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.11.6.5.2 |
gx2EDFAHoldTimeDataThe value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds.rw INTEGER .1.3.6.1.4.1.1166.6.1.2.11.6.5.3 |