Home/Catalog/OMNI-gx2EDFA-MIB

OMNI-gx2EDFA-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for OMNI-gx2EDFA-MIB.

272
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

272 total
Object Name
trapEDFAConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.1
trapEDFAConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.2
trapEDFAModuleTemperatureAlarmThis trap is issued when the EDFA Module's Temperature goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.3
trapEDFAOpticalInPowerAlarmThis trap is issued when the input Optical Input Power parameter goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.4
trapEDFAOpticalOutPowerAlarmThis trap is issued when the input Optical Output Power parameter goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.5
trapEDFATECTemperatureAlarmThis trap is issued when the EDFA TEC Temperature goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.6
trapEDFATECCurrentAlarmThis trap is issued when the EDFA TEC Current goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.7
trapEDFALaserCurrentAlarmThis trap is issued when the EDFA Laser Current goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.8
trapEDFALaserPowerAlarmThis trap is issued when the EDFA Laser Power goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.9
trapEDFAPlus12CurrentAlarmThis trap is issued when the EDFA 12 volt current parameter goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.10
trapEDFAPlus37CurrentAlarmThis trap is issued when the EDFA 3.7 volt current parameter goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.11
trapEDFAFanCurrentAlarmThis trap is issued when the EDFA Module's Fan Currrent parameter goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.12
trapEDFAResetFacDefaultThis trap is issued when the EDFA resets to factory defaults
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.13
trapEDFAStandbyModeThis trap is issued when the EDFA is in Standby Mode.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.14
trapEDFAOptInShutdownThis trap is issued when the EDFA is in Optical Input Shutdown.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.15
trapEDFATECTempShutdownThis trap is issued when the EDFA is in TEC Temperature Shutdown.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.16
trapEDFAKeySwitchThis trap is issued when the Key Switch disables the EDFA.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.17
trapEDFAPowerFailThis trap is issued when there is an EDFA Power Supply Failure.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.18
trapEDFALasCurrShutdownThis trap is issued when the EDFA is in Laser Current Shutdown.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.19
trapEDFALasPowerShutdownThis trap is issued when the EDFA is in Laser Power Shutdown.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.20
trapEDFAInvalidModeThis trap is issued when the EDFA is in an invalid mode.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.21
trapEDFAFlashAlarmThis trap is issued when the EDFA Module's boot or flash programming sequence has detected a Flash error.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.22
trapEDFABoot0AlarmThis trap is issued when the EDFA Module's Bank 0 Boot sequence has detected an error.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.23
trapEDFABoot1AlarmThis trap is issued when the EDFA Module's Bank 1 Boot sequence has detected an error.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.24
trapEDFAAlarmDataCRCAlarmThis trap is issued when the EDFA Module detects an error calculating the alarm limit CRC.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.25
trapEDFAFactoryDataCRCAlarmThis trap is issued when the EDFA Module detects an error calculating the Factory data CRC.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.26
trapEDFACalDataCRCAlarmThis trap is issued when the EDFA Module detects an error calculating the Calibration data CRC.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.27
trapEDFAFacCalFloatAlarmThis trap is issued when the EDFA Module detects factory calibration float data alarm.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.28
trapEDFAOptInThreshAlarmThis trap is issued when the EDFA Module Optical Input drops below the user set threshold.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.29
trapEDFAGainErrorAlarmThis trap is issued when the EDFA Module cannot produce the desired user set gain in Constant Gain Set Mode.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.11.0.30
gx2EDFADescriptor
OBJECT IDENTIFIER
.1.3.6.1.4.1.1166.6.1.2.11.1
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1166.6.1.2.11.1
gx2EDFAAnalogTableThis table contains gx2EDFA specific parameters with nominal and current values.
SEQUENCE OF Gx2EDFAAnalogEntry
.1.3.6.1.4.1.1166.6.1.2.11.2
gx2EDFAAnalogEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2EDFAAnalogEntry
.1.3.6.1.4.1.1166.6.1.2.11.2.1
edfagx2EDFAAnalogTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.2.1.1
edfalabelModTempThe value of this object provides the label of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.2
edfauomModTempThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.3
edfamajorHighModTempThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.4
edfamajorLowModTempThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.5
edfaminorHighModTempThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.6
edfaminorLowModTempThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.7
edfacurrentValueModTempThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.8
edfastateFlagModTempThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.9
edfaminValueModTempThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.10
edfamaxValueModTempThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.11
edfaalarmStateModTempThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.12
edfalabelOptInPowerThe value of this object provides the label of the Optical Input Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.13
edfauomOptInPowerThe value of this object provides the Unit of Measure of the Optical Input Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.14
edfamajorHighOptInPowerThe value of this object provides the Major High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.15
edfamajorLowOptInPowerThe value of this object provides the Major Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.16
edfaminorHighOptInPowerThe value of this object provides the Minor High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.17
edfaminorLowOptInPowerThe value of this object provides the Minor Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.18
edfacurrentValueOptInPowerThe value of this object provides the Current value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.19
edfastateFlagOptInPowerThe value of this object provides the state of the Optical Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.20
edfaminValueOptInPowerThe value of this object provides the minimum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.21
edfamaxValueOptInPowerThe value of this object provides the maximum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.22
edfaalarmStateOptInPowerThe value of this object provides the curent alarm state of the Optical Input Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.23
edfalabelOptOutPowerThe value of this object provides the label of the Optical Output Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.24
edfauomOptOutPowerThe value of this object provides the Unit of Measure of the Optical Output Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.25
edfamajorHighOptOutPowerThe value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.26
edfamajorLowOptOutPowerThe value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.27
edfaminorHighOptOutPowerThe value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.28
edfaminorLowOptOutPowerThe value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.29
edfacurrentValueOptOutPowerThe value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.30
edfastateFlagOptOutPowerThe value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.31
edfaminValueOptOutPowerThe value of this object provides the minimum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.32
edfamaxValueOptOutPowerThe value of this object provides the maximum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.33
edfaalarmStateOptOutPowerThe value of this object provides the curent alarm state of the Optical Output Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.34
edfalabelTECTempThe value of this object provides the label of the TEC Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.35
edfauomTECTempThe value of this object provides the Unit of Measure of the TEC Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.36
edfamajorHighTECTempThe value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.37
edfamajorLowTECTempThe value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.38
edfaminorHighTECTempThe value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.39
edfaminorLowTECTempThe value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.40
edfacurrentValueTECTempThe value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.41
edfastateFlagTECTempThe value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.42
edfaminValueTECTempThe value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.43
edfamaxValueTECTempThe value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.44
edfaalarmStateTECTempThe value of this object provides the curent alarm state of the TEC Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.45
edfalabelTECCurrentThe value of this object provides the label of the TEC Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.46
edfauomTECCurrentThe value of this object provides the Unit of Measure of the TEC Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.47
edfamajorHighTECCurrentThe value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.48
edfamajorLowTECCurrentThe value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.49
edfaminorHighTECCurrentThe value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.50
edfaminorLowTECCurrentThe value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.51
edfacurrentValueTECCurrentThe value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.52
edfastateFlagTECCurrentThe value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.53
edfaminValueTECCurrentThe value of this object provides the minimum value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.54
edfamaxValueTECCurrentThe value of this object provides the maximum value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.55
edfaalarmStateTECCurrentThe value of this object provides the curent alarm state of the TEC Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.56
edfalabelLaserCurrentThe value of this object provides the label of the Laser Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.57
edfauomLaserCurrentThe value of this object provides the Unit of Measure of the Laser Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.58
edfamajorHighLaserCurrentThe value of this object provides the Major High alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.59
edfamajorLowLaserCurrentThe value of this object provides the Major Low alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.60
edfaminorHighLaserCurrentThe value of this object provides the Minor High alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.61
edfaminorLowLaserCurrentThe value of this object provides the Minor Low alarm value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.62
edfacurrentValueLaserCurrentThe value of this object provides the Current value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.63
edfastateFlagLaserCurrentThe value of this object provides the state of the Laser Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.64
edfaminValueLaserCurrentThe value of this object provides the minimum value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.65
edfamaxValueLaserCurrentThe value of this object provides the maximum value of the Laser Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.66
edfaalarmStateLaserCurrentThe value of this object provides the curent alarm state of the Laser Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.67
edfalabelLaserPowerThe value of this object provides the label of the Laser Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.68
edfauomLaserPowerThe value of this object provides the Unit of Measure of the Laser Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.69
edfamajorHighLaserPowerThe value of this object provides the Major High alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.70
edfamajorLowLaserPowerThe value of this object provides the Major Low alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.71
edfaminorHighLaserPowerThe value of this object provides the Minor High alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.72
edfaminorLowLaserPowerThe value of this object provides the Minor Low alarm value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.73
edfacurrentValueLaserPowerThe value of this object provides the Current value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.74
edfastateFlagLaserPowerThe value of this object provides the state of the Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.75
edfaminValueLaserPowerThe value of this object provides the minimum value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.76
edfamaxValueLaserPowerThe value of this object provides the maximum value of the Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.77
edfaalarmStateLaserPowerThe value of this object provides the curent alarm state of the Laser Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.78
edfalabel12VoltThe value of this object provides the label of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.79
edfauom12VoltThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.80
edfamajorHigh12VoltThe value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.81
edfamajorLow12VoltThe value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.82
edfaminorHigh12VoltThe value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.83
edfaminorLow12VoltThe value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.84
edfacurrentValue12VoltThe value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.85
edfastateFlag12VoltThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.86
edfaminValue12VoltThe value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.87
edfamaxValue12VoltThe value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.88
edfaalarmState12VoltThe value of this object provides the curent alarm state of the 12v Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.89
edfalabel37VoltThe value of this object provides the label of the 3.7v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.90
edfauom37VoltThe value of this object provides the Unit of Measure of the 3.7v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.91
edfamajorHigh37VoltThe value of this object provides the Major High alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.92
edfamajorLow37VoltThe value of this object provides the Major Low alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.93
edfaminorHigh37VoltThe value of this object provides the Minor High alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.94
edfaminorLow37VoltThe value of this object provides the Minor Low alarm value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.95
edfacurrentValue37VoltThe value of this object provides the Current value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.96
edfastateFlag37VoltThe value of this object provides the state of the 3.7v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.97
edfaminValue37VoltThe value of this object provides the minimum value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.98
edfamaxValue37VoltThe value of this object provides the maximum value of the 3.7 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.99
edfaalarmState37VoltThe value of this object provides the curent alarm state of the 3.7v Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.100
edfalabelFanCurrentThe value of this object provides the label of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.101
edfauomFanCurrentThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.102
edfamajorHighFanCurrentThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.103
edfamajorLowFanCurrentThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.104
edfaminorHighFanCurrentThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.105
edfaminorLowFanCurrentThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.106
edfacurrentValueFanCurrentThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.107
edfastateFlagFanCurrentThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.108
edfaminValueFanCurrentThe value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.109
edfamaxValueFanCurrentThe value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.110
edfaalarmStateFanCurrentThe value of this object provides the curent alarm state of the Fan Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.111
edfalabelOPSettingThe value of this object provides the label of the Output Power Setting Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.112
edfauomOPSettingThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.113
edfamajorHighOPSettingThe value of this object provides the Major High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.114
edfamajorLowOPSettingThe value of this object provides the Major Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.115
edfaminorHighOPSettingThe value of this object provides the Minor High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.116
edfaminorLowOPSettingThe value of this object provides the Minor Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.117
edfacurrentValueOPSettingThe value of this object provides the Current value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.rw
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.118
edfastateFlagOPSettingThe value of this object provides the state of the Output Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.119
edfaminValueOPSettingThe value of this object provides the minimum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.120
edfamaxValueOPSettingThe value of this object provides the maximum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.121
edfaalarmStateOPSettingThe value of this object provides the curent alarm state of the Output Power Setting Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.122
edfalabelLPSettingThe value of this object provides the label of the Laser Power Setting Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.123
edfauomLPSettingThe value of this object provides the Unit of Measure of the Laser Power Setting Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.124
edfamajorHighLPSettingThe value of this object provides the Major High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.125
edfamajorLowLPSettingThe value of this object provides the Major Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.126
edfaminorHighLPSettingThe value of this object provides the Minor High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.127
edfaminorLowLPSettingThe value of this object provides the Minor Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.128
edfacurrentValueLPSettingThe value of this object provides the Current value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.rw
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.129
edfastateFlagLPSettingThe value of this object provides the state of the Laser Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.130
edfaminValueLPSettingThe value of this object provides the minimum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.131
edfamaxValueLPSettingThe value of this object provides the maximum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.132
edfaalarmStateLPSettingThe value of this object provides the curent alarm state of the Laser Power Setting Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.133
edfalabelCGSettingThe value of this object provides the label of the Constant Gain Setting Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.134
edfauomCGSettingThe value of this object provides the Unit of Measure of the Constant Gain Setting Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.135
edfamajorHighCGSettingThe value of this object provides the Major High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.136
edfamajorLowCGSettingThe value of this object provides the Major Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.137
edfaminorHighCGSettingThe value of this object provides the Minor High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.138
edfaminorLowCGSettingThe value of this object provides the Minor Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.139
edfacurrentValueCGSettingThe value of this object provides the Current value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.rw
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.140
edfastateFlagCGSettingThe value of this object provides the state of the Constant Gain Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.141
edfaminValueCGSettingThe value of this object provides the minimum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.142
edfamaxValueCGSettingThe value of this object provides the maximum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.143
edfaalarmStateCGSettingThe value of this object provides the curent alarm state of the Constant Gain Setting Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.144
edfalabelOptThresholdThe value of this object provides the label of the Optical Input Threshold Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.145
edfauomOptThresholdThe value of this object provides the Unit of Measure of the Optical Input Threshold Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.2.1.146
edfamajorHighOptThresholdThe value of this object provides the Major High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.147
edfamajorLowOptThresholdThe value of this object provides the Major Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.148
edfaminorHighOptThresholdThe value of this object provides the Minor High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.149
edfaminorLowOptThresholdThe value of this object provides the Minor Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.150
edfacurrentValueOptThresholdThe value of this object provides the Current value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.rw
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.151
edfastateFlagOptThresholdThe value of this object provides the state of the Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.152
edfaminValueOptThresholdThe value of this object provides the minimum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.153
edfamaxValueOptThresholdThe value of this object provides the maximum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.11.2.1.154
edfaalarmStateOptThresholdThe value of this object provides the curent alarm state of the Optical Input Threshold Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.2.1.155
gx2EDFADigitalTableThis table contains gx2EDFA specific parameters with nominal and current values.
SEQUENCE OF Gx2EDFADigitalEntry
.1.3.6.1.4.1.1166.6.1.2.11.3
gx2EDFADigitalEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2EDFADigitalEntry
.1.3.6.1.4.1.1166.6.1.2.11.3.2
edfagx2EDFADigitalTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.3.2.1
edfalabelModeSettingThe value of this object provides the label of the EDFA's Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.3.2.2
edfaenumModeSettingThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.3.2.3
edfavalueModeSettingThe value of this object is the current value of the parameter. It is an integer value from 0 to 5 representing the operation mode of the module.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.3.2.4
edfastateFlagModeSettingThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.3.2.5
edfalabelModuleStateThe value of this object provides the label of the Module State Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.3.2.6
edfaenumModuleStateThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.3.2.7
edfavalueModuleStateThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.3.2.8
edfastateFlagModuleStateThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.3.2.9
edfalabelFactoryDefaultThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.3.2.10
edfaenumFactoryDefaultThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.3.2.11
edfavalueFactoryDefaultThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.3.2.12
edfastateFlagFactoryDefaultThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.3.2.13
gx2EDFAStatusTableThis table contains gx2EDFA specific parameters with nominal and current values.
SEQUENCE OF Gx2EDFAStatusEntry
.1.3.6.1.4.1.1166.6.1.2.11.4
gx2EDFAStatusEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2EDFAStatusEntry
.1.3.6.1.4.1.1166.6.1.2.11.4.3
edfagx2EDFAStatusTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.4.3.1
edfalabelBootThe value of this object provides the label of the Boot Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.2
edfavalueBootThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.3
edfastateflagBootThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.4
edfalabelFlashThe value of this object provides the label of the Flash Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.5
edfavalueFlashThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.6
edfastateflagFlashThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.7
edfalabelFactoryDataCRCThe value of this object provides the label of the Factory Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.8
edfavalueFactoryDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.9
edfastateflagFactoryDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.10
edfalabelAlarmDataCRCThe value of this object provides the label of the Alarm Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.11
edfavalueAlarmDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.12
edfastateflagAlarmDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.13
edfalabelCalibrationDataCRCThe value of this object provides the label of the Calibration Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.14
edfavalueCalibrationDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.15
edfastateflagCalibrationDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.16
edfalabelOptInShutdownThe value of this object provides the label of the Optical Input Power Shutdown Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.17
edfavalueOptInShutdownThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.18
edfastateflagOptInShutdownThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.19
edfalabelTECTempShutdownThe value of this object provides the label of the TEC Temperature Shutdown Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.20
edfavalueTECTempShutdownThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.21
edfastateflagTECTempShutdownThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.22
edfalabelTECShutOverrideThe value of this object provides the label of the TEC Shutdown Override Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.23
edfavalueTECShutOverrideThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.24
edfastateflagTECShutOverrideThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.25
edfalabelPowerFailThe value of this object provides the label of the Power Supply Fail Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.26
edfavaluePowerFailThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.27
edfastateflagPowerFailThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.28
edfalabelKeySwitchThe value of this object provides the label of the Key Switch Setting Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.29
edfavalueKeySwitchThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.30
edfastateflagKeySwitchThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.31
edfalabelLaserCurrShutdownThe value of this object provides the label of the Laser Current Shutdown Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.32
edfavalueLaserCurrShutdownThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.33
edfastateflagLaserCurrShutdownThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.34
edfalabelLaserPowShutdownThe value of this object provides the label of the Laser Power Shutdown Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.35
edfavalueLaserPowShutdownThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.36
edfastateflagLaserPowShutdownThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.37
edfalabelADCStatusThe value of this object provides the label of the ADC Operation Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.38
edfavalueADCStatusThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.39
edfastateflagADCStatusThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.40
edfalabelConstGainStatusThe value of this object provides the label of the Constant Gain Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.41
edfavalueConstGainStatusThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.42
edfastateflagConstGainStatusThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.43
edfalabelStandbyStatusThe value of this object provides the label of the Standby Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.4.3.44
edfavalueStandbyStatusThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.45
edfastateflagStandbyStatusThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.4.3.46
gx2EDFAFactoryTableThis table contains gx2EDFA specific parameters with nominal and current values.
SEQUENCE OF Gx2EDFAFactoryEntry
.1.3.6.1.4.1.1166.6.1.2.11.5
gx2EDFAFactoryEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2EDFAFactoryEntry
.1.3.6.1.4.1.1166.6.1.2.11.5.4
edfagx2EDFAFactoryTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.5.4.1
edfabootControlByteThe value of this object indicates which bank the firmware is currently being boot from.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.5.4.2
edfabootStatusByteThis object indicates the status of the last bootro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.5.4.3
edfabank0CRCThis object provides the CRC code of bank 0.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.5.4.4
edfabank1CRCThis object provides the CRC code of bank 1.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.5.4.5
edfaprgEEPROMByteThis object indicates if the EEPROM has been programmedro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.5.4.6
edfafactoryCRCThis object provides the CRC code for the Factory data.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.5.4.7
edfacalculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.11.5.4.8
edfahourMeterThis object provides the hour meter reading of the module.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.5.4.9
edfaflashPrgCntAThis object provides the number of times the flash has been programmed on side A.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.5.4.10
edfaflashPrgCntBThis object provides the number of times the flash has been programmed on side B.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.5.4.11
edfafwRev0This object provides the Revision of the firmware stores in bank 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.5.4.12
edfafwRev1This object provides the Revision of the firmware stores in bank 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.11.5.4.13
gx2EDFAHoldTimeTableThis table contains gx2EDFA specific parameters with nominal and current values.
SEQUENCE OF Gx2EDFAHoldTimeEntry
.1.3.6.1.4.1.1166.6.1.2.11.6
gx2EDFAHoldTimeEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2EDFAHoldTimeEntry
.1.3.6.1.4.1.1166.6.1.2.11.6.5
gx2EDFAHoldTimeTableIndexThe value of this object is the index of the data object.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.6.5.1
gx2EDFAHoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.6.5.2
gx2EDFAHoldTimeDataThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.rw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.11.6.5.3
OMNI-gx2EDFA-MIB - SNMP MIB Reference | MIBs Explorer