265
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

265 total
Object Name
trapRx200BX4ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.1
trapRx200BX4ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.2
trapRx200BX4OpticalPower1AlarmThis trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.3
trapRx200BX4OpticalPower2AlarmThis trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.4
trapRx200BX4OpticalPower3AlarmThis trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.5
trapRx200BX4OpticalPower4AlarmThis trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.6
trapRx200BX4ModuleTemperatureAlarmThis trap is issued when the Rx200BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.7
trapRx200BX4FanCurrentAlarmThis trap is issued when the Rx200BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.8
trapRx200BX4Plus12CurrentAlarmThis trap is issued when the Rx200BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.9
trapRx200BX4Boot0AlarmThis trap is issued when the Rx200BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.10
trapRx200BX4Boot1AlarmThis trap is issued when the Rx200BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.11
trapRx200BX4FlashAlarmThis trap is issued when the Rx200BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.12
trapRx200BX4AlarmDataCRCAlarmThis trap is issued when the Rx200BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.13
trapRx200BX4FactoryDataCRCAlarmThis trap is issued when the Rx200BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.14
trapRx200BX4CalDataCRCAlarmThis trap is issued when the Rx200BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.15
trapRx200BX4DefaultAlarmThis trap is issued when the Rx200BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.16
trapRx200BX4Mode1AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.17
trapRx200BX4Mode2AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.18
trapRx200BX4Mode3AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.19
trapRx200BX4Mode4AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.20
trapRx200BX4Output1SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.21
trapRx200BX4Output2SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.22
trapRx200BX4Output3SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.23
trapRx200BX4Output4SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.24
trapRx200BX4RX1StatusAlarmThis trap is issued when receiver 1 of the Rx200BX4 Module output is turned on or off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.25
trapRx200BX4RX2StatusAlarmThis trap is issued when receiver 2 of the Rx200BX4 Module output is turned on or off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.26
trapRx200BX4RX3StatusAlarmThis trap is issued when receiver 3 of the Rx200BX4 Module output is turned on or off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.27
trapRx200BX4RX4StatusAlarmThis trap is issued when receiver 4 of the Rx200BX4 Module output is turned on or off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.28
trapRx200BX4BackupCableAlarmThis trap is issued when the slave receiver loses connection to the master receiver.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.29
trapRx200BX4OptPwr1BadAlarmThis trap is issued when the receiver 1 optical power level falls below the user set switching threshold.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.30
trapRx200BX4OptPwr2BadAlarmThis trap is issued when the receiver 2 optical power level falls below the user set switching threshold.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.31
trapRx200BX4OptPwr3BadAlarmThis trap is issued when the receiver 3 optical power level falls below the user set switching threshold.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.32
trapRx200BX4OptPwr4BadAlarmThis trap is issued when the receiver 4 optical power level falls below the user set switching threshold.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.29.0.33
gx2Rx200BX4Descriptor
OBJECT IDENTIFIER
.1.3.6.1.4.1.1166.6.1.2.29.1
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1166.6.1.2.29.1
gx2Rx200BX4AnalogTableThis table contains gx2Rx200BX4 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx200BX4AnalogEntry
.1.3.6.1.4.1.1166.6.1.2.29.2
gx2Rx200BX4AnalogEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx200BX4AnalogEntry
.1.3.6.1.4.1.1166.6.1.2.29.2.1
gx2Rx200BX4AnalogTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.2.1.1
rx4labelOptPowerOneThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.2
rx4uomOptPowerOneThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.3
rx4majorHighOptPowerOneThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.4
rx4majorLowOptPowerOneThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.5
rx4minorHighOptPowerOneThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.6
rx4minorLowOptPowerOneThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.7
rx4currentValueOptPowerOneThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.8
rx4stateFlagOptPowerOneThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.9
rx4minValueOptPowerOneThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.10
rx4maxValueOptPowerOneThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.11
rx4alarmStateOptPowerOneThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.12
rx4labelOptPowerTwoThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.13
rx4uomOptPowerTwoThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.14
rx4majorHighOptPowerTwoThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.15
rx4majorLowOptPowerTwoThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.16
rx4minorHighOptPowerTwoThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.17
rx4minorLowOptPowerTwoThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.18
rx4currentValueOptPowerTwoThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.19
rx4stateFlagOptPowerTwoThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.20
rx4minValueOptPowerTwoThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.21
rx4maxValueOptPowerTwoThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.22
rx4alarmStateOptPowerTwoThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.23
rx4labelOptPowerThreeThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.24
rx4uomOptPowerThreeThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.25
rx4majorHighOptPowerThreeThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.26
rx4majorLowOptPowerThreeThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.27
rx4minorHighOptPowerThreeThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.28
rx4minorLowOptPowerThreeThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.29
rx4currentValueOptPowerThreeThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.30
rx4stateFlagOptPowerThreeThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.31
rx4minValueOptPowerThreeThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.32
rx4maxValueOptPowerThreeThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.33
rx4alarmStateOptPowerThreeThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.34
rx4labelOptPowerFourThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.35
rx4uomOptPowerFourThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.36
rx4majorHighOptPowerFourThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.37
rx4majorLowOptPowerFourThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.38
rx4minorHighOptPowerFourThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.39
rx4minorLowOptPowerFourThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.40
rx4currentValueOptPowerFourThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.41
rx4stateFlagOptPowerFourThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.42
rx4minValueOptPowerFourThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.43
rx4maxValueOptPowerFourThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.44
rx4alarmStateOptPowerFourThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.45
rx4labelModTempThe value of this object provides the label of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.46
rx4uomModTempThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.47
rx4majorHighModTempThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.48
rx4majorLowModTempThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.49
rx4minorHighModTempThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.50
rx4minorLowModTempThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.51
rx4currentValueModTempThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.52
rx4stateFlagModTempThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.53
rx4minValueModTempThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.54
rx4maxValueModTempThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.55
rx4alarmStateModTempThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.56
rx4labelFanCurrentThe value of this object provides the label of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.57
rx4uomFanCurrentThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.58
rx4majorHighFanCurrentThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.59
rx4majorLowFanCurrentThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.60
rx4minorHighFanCurrentThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.61
rx4minorLowFanCurrentThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.62
rx4currentValueFanCurrentThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.63
rx4stateFlagFanCurrentThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.64
rx4minValueFanCurrentThe value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.65
rx4maxValueFanCurrentThe value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.66
rx4alarmStateFanCurrentThe value of this object provides the curent alarm state of the Fan Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.67
rx4label12VoltThe value of this object provides the label of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.68
rx4uom12VoltThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.2.1.69
rx4majorHigh12VoltThe value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.70
rx4majorLow12VoltThe value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.71
rx4minorHigh12VoltThe value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.72
rx4minorLow12VoltThe value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.73
rx4currentValue12VoltThe value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.74
rx4stateFlag12VoltThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.75
rx4minValue12VoltThe value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.76
rx4maxValue12VoltThe value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.29.2.1.77
rx4alarmState12VoltThe value of this object provides the curent alarm state of the 12v Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.2.1.78
gx2Rx200BX4DigitalTableThis table contains gx2Rx200BX4 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx200BX4DigitalEntry
.1.3.6.1.4.1.1166.6.1.2.29.3
gx2Rx200BX4DigitalEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx200BX4DigitalEntry
.1.3.6.1.4.1.1166.6.1.2.29.3.2
gx2Rx200BX4DigitalTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.3.2.1
rx4labelModeOneThe value of this object provides the label of the Rx200BX4's Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.2
rx4enumModeOneThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.3
rx4valueModeOneThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.4
rx4stateFlagModeOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.5
rx4labelWavelengthOneThe value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.6
rx4enumWavelengthOneThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.7
rx4valueWavelengthOneThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.8
rx4stateFlagWavelengthOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.9
rx4labelAttnSettingOneThe value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.10
rx4enumAttnSettingOneThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.11
rx4valueAttnSettingOneThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.3.2.12
rx4stateFlagAttnSettingOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.13
rx4labelSwModeSettingOneThe value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.14
rx4enumSwModeSettingOneThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.15
rx4valueSwModeSettingOneThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.16
rx4stateFlagSwModeSettingOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.17
rx4labelSwModeThresholdOneThe value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.18
rx4enumSwModeThresholdOneThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.19
rx4valueSwModeThresholdOneThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.3.2.20
rx4stateFlagSwModeThresholdOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.21
rx4labelModeTwoThe value of this object provides the label of the Rx200BX4's Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.22
rx4enumModeTwoThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.23
rx4valueModeTwoThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.24
rx4stateFlagModeTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.25
rx4labelWavelengthTwoThe value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.26
rx4enumWavelengthTwoThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.27
rx4valueWavelengthTwoThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.28
rx4stateFlagWavelengthTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.29
rx4labelAttnSettingTwoThe value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.30
rx4enumAttnSettingTwoThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.31
rx4valueAttnSettingTwoThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.3.2.32
rx4stateFlagAttnSettingTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.33
rx4labelSwModeSettingTwoThe value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.34
rx4enumSwModeSettingTwoThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.35
rx4valueSwModeSettingTwoThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.36
rx4stateFlagSwModeSettingTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.37
rx4labelSwModeThresholdTwoThe value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.38
rx4enumSwModeThresholdTwoThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.39
rx4valueSwModeThresholdTwoThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.3.2.40
rx4stateFlagSwModeThresholdTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.41
rx4labelModeThreeThe value of this object provides the label of the Rx200BX4's Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.42
rx4enumModeThreeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.43
rx4valueModeThreeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.44
rx4stateFlagModeThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.45
rx4labelWavelengthThreeThe value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.46
rx4enumWavelengthThreeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.47
rx4valueWavelengthThreeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.48
rx4stateFlagWavelengthThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.49
rx4labelAttnSettingThreeThe value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.50
rx4enumAttnSettingThreeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.51
rx4valueAttnSettingThreeThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.3.2.52
rx4stateFlagAttnSettingThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.53
rx4labelSwModeSettingThreeThe value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.54
rx4enumSwModeSettingThreeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.55
rx4valueSwModeSettingThreeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.56
rx4stateFlagSwModeSettingThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.57
rx4labelSwModeThresholdThreeThe value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.58
rx4enumSwModeThresholdThreeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.59
rx4valueSwModeThresholdThreeThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.3.2.60
rx4stateFlagSwModeThresholdThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.61
rx4labelModeFourThe value of this object provides the label of the Rx200BX4's Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.62
rx4enumModeFourThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.63
rx4valueModeFourThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.64
rx4stateFlagModeFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.65
rx4labelWavelengthFourThe value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.66
rx4enumWavelengthFourThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.67
rx4valueWavelengthFourThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.68
rx4stateFlagWavelengthFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.69
rx4labelAttnSettingFourThe value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.70
rx4enumAttnSettingFourThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.71
rx4valueAttnSettingFourThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.3.2.72
rx4stateFlagAttnSettingFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.73
rx4labelSwModeSettingFourThe value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.74
rx4enumSwModeSettingFourThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.75
rx4valueSwModeSettingFourThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.76
rx4stateFlagSwModeSettingFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.77
rx4labelSwModeThresholdFourThe value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.78
rx4enumSwModeThresholdFourThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.79
rx4valueSwModeThresholdFourThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.3.2.80
rx4stateFlagSwModeThresholdFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.81
rx4labelModuleConfigThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.82
rx4enumModuleConfigThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.83
rx4valueModuleConfigThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.84
rx4stateFlagModuleConfigThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.85
rx4labelRevertTimeThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.86
rx4enumRevertTimeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.87
rx4valueRevertTimeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.88
rx4stateFlagRevertTimeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.89
rx4labelTestPointSelectThe value of this object provides the label of the Test point Select Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.90
rx4enumTestPointSelectThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.91
rx4valueTestPointSelectThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.92
rx4stateFlagTestPointSelectThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.93
rx4labelFactoryDefaultThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.94
rx4enumFactoryDefaultThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.3.2.95
rx4valueFactoryDefaultThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.96
rx4stateFlagFactoryDefaultThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.3.2.97
gx2Rx200BX4StatusTableThis table contains gx2Rx200BX4 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx200BX4StatusEntry
.1.3.6.1.4.1.1166.6.1.2.29.4
gx2Rx200BX4StatusEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx200BX4StatusEntry
.1.3.6.1.4.1.1166.6.1.2.29.4.3
gx2Rx200BX4StatusTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.4.3.1
rx4labelBootThe value of this object provides the label of the Boot Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.2
rx4valueBootThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.3
rx4stateflagBootThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.4
rx4labelFlashThe value of this object provides the label of the Flash Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.5
rx4valueFlashThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.6
rx4stateflagFlashThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.7
rx4labelFactoryDataCRCThe value of this object provides the label of the Factory Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.8
rx4valueFactoryDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.9
rx4stateflagFactoryDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.10
rx4labelAlarmDataCRCThe value of this object provides the label of the Alarm Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.11
rx4valueAlarmDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.12
rx4stateflagAlarmDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.13
rx4labelCalibrationDataCRCThe value of this object provides the label of the Calibration Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.14
rx4valueCalibrationDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.15
rx4stateflagCalibrationDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.16
rx4labelHWThe value of this object provides the label of the Hardware Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.17
rx4valueHWThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.18
rx4stateflagHWThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.19
rx4labelOptSigOneThe value of this object provides the label of the Optical Signal Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.20
rx4valueOptSigOneThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.21
rx4stateflagOptSigOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.22
rx4labelOptSigTwoThe value of this object provides the label of the Optical Signal Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.23
rx4valueOptSigTwoThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.24
rx4stateflagOptSigTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.25
rx4labelOptSigThreeThe value of this object provides the label of the Optical Signal Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.26
rx4valueOptSigThreeThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.27
rx4stateflagOptSigThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.28
rx4labelOptSigFourThe value of this object provides the label of the Optical Signal Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.29
rx4valueOptSigFourThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.30
rx4stateflagOptSigFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.31
rx4labelBackupCableThe value of this object provides the label of the Backup Cable Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.4.3.32
rx4valueBackupCableThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.33
rx4stateflagBackupCableThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.4.3.34
gx2Rx200BX4FactoryTableThis table contains gx2Rx200BX4 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx200BX4FactoryEntry
.1.3.6.1.4.1.1166.6.1.2.29.5
gx2Rx200BX4FactoryEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx200BX4FactoryEntry
.1.3.6.1.4.1.1166.6.1.2.29.5.4
gx2Rx200BX4FactoryTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.5.4.1
rx4bootControlByteThe value of this object indicates which bank the firmware is currently being boot from.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.5.4.2
rx4bootStatusByteThis object indicates the status of the last bootro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.5.4.3
rx4bank0CRCThis object provides the CRC code of bank 0.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.5.4.4
rx4bank1CRCThis object provides the CRC code of bank 1.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.5.4.5
rx4prgEEPROMByteThis object indicates if the EEPROM has been programmedro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.5.4.6
rx4factoryCRCThis object provides the CRC code for the Factory data.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.5.4.7
rx4calculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.29.5.4.8
rx4hourMeterThis object provides the hour meter reading of the module.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.5.4.9
rx4flashPrgCntAThis object provides the number of times the flash has been programmed on side A.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.5.4.10
rx4flashPrgCntBThis object provides the number of times the flash has been programmed on side B.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.29.5.4.11
rx4fwRev0This object provides the Revision of the firmware stores in bank 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.5.4.12
rx4fwRev1This object provides the Revision of the firmware stores in bank 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.29.5.4.13