OMNI-gx2Rx200BX4-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
265
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
265 total| Object Name |
|---|
trapRx200BX4ConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.1 |
trapRx200BX4ConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.2 |
trapRx200BX4OpticalPower1AlarmThis trap is issued when the Receiver's channel 1 Optical Power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.3 |
trapRx200BX4OpticalPower2AlarmThis trap is issued when the Receiver's channel 2 Optical Power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.4 |
trapRx200BX4OpticalPower3AlarmThis trap is issued when the Receiver's channel 3 Optical Power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.5 |
trapRx200BX4OpticalPower4AlarmThis trap is issued when the Receiver's channel 4 Optical Power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.6 |
trapRx200BX4ModuleTemperatureAlarmThis trap is issued when the Rx200BX4 Modules Temperature goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.7 |
trapRx200BX4FanCurrentAlarmThis trap is issued when the Rx200BX4 Modules Fan Currrent parameter
goes out of range. trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.8 |
trapRx200BX4Plus12CurrentAlarmThis trap is issued when the Rx200BX4 Modules positive 12 volt current parameter
goes out of range. trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.9 |
trapRx200BX4Boot0AlarmThis trap is issued when the Rx200BX4 Modules Bank 0 Boot sequence has detected an error.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.10 |
trapRx200BX4Boot1AlarmThis trap is issued when the Rx200BX4 Modules Bank 1 Boot sequence has detected an error.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.11 |
trapRx200BX4FlashAlarmThis trap is issued when the Rx200BX4 Modules boot or flash programming sequence has
detected a Flash error. trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.12 |
trapRx200BX4AlarmDataCRCAlarmThis trap is issued when the Rx200BX4 Module detects an error calculating the alarm limit CRC.
trapAdditionalInfoInteger variable contains current reading of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.13 |
trapRx200BX4FactoryDataCRCAlarmThis trap is issued when the Rx200BX4 Module detects an error calculating the Factory data CRC.
trapAdditionalInfoInteger variable contains current reading of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.14 |
trapRx200BX4CalDataCRCAlarmThis trap is issued when the Rx200BX4 Module detects an error calculating the Calibration data CRC.
trapAdditionalInfoInteger variable contains current reading of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.15 |
trapRx200BX4DefaultAlarmThis trap is issued when the Rx200BX4 Module is reset to it's factory default state.
trapAdditionalInfoInteger variable contains current reading of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.16 |
trapRx200BX4Mode1AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back.
trapAdditionalInfoInteger variable contains current reading of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.17 |
trapRx200BX4Mode2AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back.
trapAdditionalInfoInteger variable contains current reading of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.18 |
trapRx200BX4Mode3AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back.
trapAdditionalInfoInteger variable contains current reading of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.19 |
trapRx200BX4Mode4AlarmThis trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back.
trapAdditionalInfoInteger variable contains current reading of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.20 |
trapRx200BX4Output1SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 1 output to the RF Switch Module changes state
from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading
of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.21 |
trapRx200BX4Output2SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 2 output to the RF Switch Module changes state
from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading
of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.22 |
trapRx200BX4Output3SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 3 output to the RF Switch Module changes state
from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading
of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.23 |
trapRx200BX4Output4SwitchedAlarmThis trap is issued when the Rx200BX4 Module's receiver 4 output to the RF Switch Module changes state
from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading
of the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.24 |
trapRx200BX4RX1StatusAlarmThis trap is issued when receiver 1 of the Rx200BX4 Module output is turned on or off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.25 |
trapRx200BX4RX2StatusAlarmThis trap is issued when receiver 2 of the Rx200BX4 Module output is turned on or off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.26 |
trapRx200BX4RX3StatusAlarmThis trap is issued when receiver 3 of the Rx200BX4 Module output is turned on or off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.27 |
trapRx200BX4RX4StatusAlarmThis trap is issued when receiver 4 of the Rx200BX4 Module output is turned on or off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.28 |
trapRx200BX4BackupCableAlarmThis trap is issued when the slave receiver loses connection to the master receiver. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.29 |
trapRx200BX4OptPwr1BadAlarmThis trap is issued when the receiver 1 optical power level falls below the user set switching threshold. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.30 |
trapRx200BX4OptPwr2BadAlarmThis trap is issued when the receiver 2 optical power level falls below the user set switching threshold. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.31 |
trapRx200BX4OptPwr3BadAlarmThis trap is issued when the receiver 3 optical power level falls below the user set switching threshold. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.32 |
trapRx200BX4OptPwr4BadAlarmThis trap is issued when the receiver 4 optical power level falls below the user set switching threshold. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.29.0.33 |
gx2Rx200BX4Descriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.29.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.29.1 |
gx2Rx200BX4AnalogTableThis table contains gx2Rx200BX4 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rx200BX4AnalogEntry .1.3.6.1.4.1.1166.6.1.2.29.2 |
gx2Rx200BX4AnalogEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rx200BX4AnalogEntry .1.3.6.1.4.1.1166.6.1.2.29.2.1 |
gx2Rx200BX4AnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.2.1.1 |
rx4labelOptPowerOneThe value of this object provides the label of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.2 |
rx4uomOptPowerOneThe value of this object provides the Unit of Measure of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.3 |
rx4majorHighOptPowerOneThe value of this object provides the Major High alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.4 |
rx4majorLowOptPowerOneThe value of this object provides the Major Low alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.5 |
rx4minorHighOptPowerOneThe value of this object provides the Minor High alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.6 |
rx4minorLowOptPowerOneThe value of this object provides the Minor Low alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.7 |
rx4currentValueOptPowerOneThe value of this object provides the Current value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.8 |
rx4stateFlagOptPowerOneThe value of this object provides the state
of the Optical Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.9 |
rx4minValueOptPowerOneThe value of this object provides the minimum value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.10 |
rx4maxValueOptPowerOneThe value of this object provides the maximum value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.11 |
rx4alarmStateOptPowerOneThe value of this object provides the curent alarm state of
the Optical Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.12 |
rx4labelOptPowerTwoThe value of this object provides the label of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.13 |
rx4uomOptPowerTwoThe value of this object provides the Unit of Measure of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.14 |
rx4majorHighOptPowerTwoThe value of this object provides the Major High alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.15 |
rx4majorLowOptPowerTwoThe value of this object provides the Major Low alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.16 |
rx4minorHighOptPowerTwoThe value of this object provides the Minor High alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.17 |
rx4minorLowOptPowerTwoThe value of this object provides the Minor Low alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.18 |
rx4currentValueOptPowerTwoThe value of this object provides the Current value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.19 |
rx4stateFlagOptPowerTwoThe value of this object provides the state
of the Optical Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.20 |
rx4minValueOptPowerTwoThe value of this object provides the minimum value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.21 |
rx4maxValueOptPowerTwoThe value of this object provides the maximum value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.22 |
rx4alarmStateOptPowerTwoThe value of this object provides the curent alarm state of
the Optical Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.23 |
rx4labelOptPowerThreeThe value of this object provides the label of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.24 |
rx4uomOptPowerThreeThe value of this object provides the Unit of Measure of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.25 |
rx4majorHighOptPowerThreeThe value of this object provides the Major High alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.26 |
rx4majorLowOptPowerThreeThe value of this object provides the Major Low alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.27 |
rx4minorHighOptPowerThreeThe value of this object provides the Minor High alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.28 |
rx4minorLowOptPowerThreeThe value of this object provides the Minor Low alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.29 |
rx4currentValueOptPowerThreeThe value of this object provides the Current value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.30 |
rx4stateFlagOptPowerThreeThe value of this object provides the state
of the Optical Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.31 |
rx4minValueOptPowerThreeThe value of this object provides the minimum value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.32 |
rx4maxValueOptPowerThreeThe value of this object provides the maximum value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.33 |
rx4alarmStateOptPowerThreeThe value of this object provides the curent alarm state of
the Optical Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.34 |
rx4labelOptPowerFourThe value of this object provides the label of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.35 |
rx4uomOptPowerFourThe value of this object provides the Unit of Measure of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.36 |
rx4majorHighOptPowerFourThe value of this object provides the Major High alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.37 |
rx4majorLowOptPowerFourThe value of this object provides the Major Low alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.38 |
rx4minorHighOptPowerFourThe value of this object provides the Minor High alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.39 |
rx4minorLowOptPowerFourThe value of this object provides the Minor Low alarm value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.40 |
rx4currentValueOptPowerFourThe value of this object provides the Current value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.41 |
rx4stateFlagOptPowerFourThe value of this object provides the state
of the Optical Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.42 |
rx4minValueOptPowerFourThe value of this object provides the minimum value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.43 |
rx4maxValueOptPowerFourThe value of this object provides the maximum value
of the Optical Power Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.44 |
rx4alarmStateOptPowerFourThe value of this object provides the curent alarm state of
the Optical Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.45 |
rx4labelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.46 |
rx4uomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.47 |
rx4majorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.48 |
rx4majorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.49 |
rx4minorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.50 |
rx4minorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.51 |
rx4currentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.52 |
rx4stateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.53 |
rx4minValueModTempThe value of this object provides the minimum value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.54 |
rx4maxValueModTempThe value of this object provides the maximum value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.55 |
rx4alarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.56 |
rx4labelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.57 |
rx4uomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.58 |
rx4majorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.59 |
rx4majorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.60 |
rx4minorHighFanCurrentThe value of this object provides the Minor High alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.61 |
rx4minorLowFanCurrentThe value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.62 |
rx4currentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.63 |
rx4stateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.64 |
rx4minValueFanCurrentThe value of this object provides the minimum value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.65 |
rx4maxValueFanCurrentThe value of this object provides the maximum value
of the Fan Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.66 |
rx4alarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.67 |
rx4label12VoltThe value of this object provides the label of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.68 |
rx4uom12VoltThe value of this object provides the Unit of Measure of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.2.1.69 |
rx4majorHigh12VoltThe value of this object provides the Major High alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.70 |
rx4majorLow12VoltThe value of this object provides the Major Low alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.71 |
rx4minorHigh12VoltThe value of this object provides the Minor High alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.72 |
rx4minorLow12VoltThe value of this object provides the Minor Low alarm value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.73 |
rx4currentValue12VoltThe value of this object provides the Current value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.74 |
rx4stateFlag12VoltThe value of this object provides the state
of the 12v Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.75 |
rx4minValue12VoltThe value of this object provides the minimum value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.76 |
rx4maxValue12VoltThe value of this object provides the maximum value
of the 12 Volt Current Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.29.2.1.77 |
rx4alarmState12VoltThe value of this object provides the curent alarm state of
the 12v Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.2.1.78 |
gx2Rx200BX4DigitalTableThis table contains gx2Rx200BX4 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rx200BX4DigitalEntry .1.3.6.1.4.1.1166.6.1.2.29.3 |
gx2Rx200BX4DigitalEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rx200BX4DigitalEntry .1.3.6.1.4.1.1166.6.1.2.29.3.2 |
gx2Rx200BX4DigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.3.2.1 |
rx4labelModeOneThe value of this object provides the label of the
Rx200BX4's Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.2 |
rx4enumModeOneThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.3 |
rx4valueModeOneThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.4 |
rx4stateFlagModeOneThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.5 |
rx4labelWavelengthOneThe value of this object provides the label of the
Rx200BX4's Wavelength Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.6 |
rx4enumWavelengthOneThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.7 |
rx4valueWavelengthOneThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.8 |
rx4stateFlagWavelengthOneThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.9 |
rx4labelAttnSettingOneThe value of this object provides the label of the
Rx200BX4's AttnSetting Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.10 |
rx4enumAttnSettingOneThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.11 |
rx4valueAttnSettingOneThe value of this object is the current value of the parameter. It is an integer
value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB.
Where 0 = 0db and 40 = 20dbrw INTEGER .1.3.6.1.4.1.1166.6.1.2.29.3.2.12 |
rx4stateFlagAttnSettingOneThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.13 |
rx4labelSwModeSettingOneThe value of this object provides the label of the
Rx200BX4's Switch Mode Setting Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.14 |
rx4enumSwModeSettingOneThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.15 |
rx4valueSwModeSettingOneThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.16 |
rx4stateFlagSwModeSettingOneThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.17 |
rx4labelSwModeThresholdOneThe value of this object provides the label of the
Rx200BX4's Switch Mode Threshold Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.18 |
rx4enumSwModeThresholdOneThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.19 |
rx4valueSwModeThresholdOneThe value of this object reflects the setting of the threshold at
which the Optical Input Failed signal is sent. It is in 1 dB increments
ranging from -2 to -17 dB. The user can enter a number from 0 to 15,
where 0 = -2db and 15= -17dbrw INTEGER .1.3.6.1.4.1.1166.6.1.2.29.3.2.20 |
rx4stateFlagSwModeThresholdOneThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.21 |
rx4labelModeTwoThe value of this object provides the label of the
Rx200BX4's Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.22 |
rx4enumModeTwoThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.23 |
rx4valueModeTwoThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.24 |
rx4stateFlagModeTwoThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.25 |
rx4labelWavelengthTwoThe value of this object provides the label of the
Rx200BX4's Wavelength Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.26 |
rx4enumWavelengthTwoThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.27 |
rx4valueWavelengthTwoThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.28 |
rx4stateFlagWavelengthTwoThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.29 |
rx4labelAttnSettingTwoThe value of this object provides the label of the
Rx200BX4's AttnSetting Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.30 |
rx4enumAttnSettingTwoThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.31 |
rx4valueAttnSettingTwoThe value of this object is the current value of the parameter. It is an integer
value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB.
Where 0 = 0db and 40 = 20dbrw INTEGER .1.3.6.1.4.1.1166.6.1.2.29.3.2.32 |
rx4stateFlagAttnSettingTwoThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.33 |
rx4labelSwModeSettingTwoThe value of this object provides the label of the
Rx200BX4's Switch Mode Setting Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.34 |
rx4enumSwModeSettingTwoThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.35 |
rx4valueSwModeSettingTwoThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.36 |
rx4stateFlagSwModeSettingTwoThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.37 |
rx4labelSwModeThresholdTwoThe value of this object provides the label of the
Rx200BX4's Switch Mode Threshold Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.38 |
rx4enumSwModeThresholdTwoThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.39 |
rx4valueSwModeThresholdTwoThe value of this object reflects the setting of the threshold at
which the Optical Input Failed signal is sent. It is in 1 dB increments
ranging from -2 to -17 dB. The user can enter a number from 0 to 15,
where 0 = -2db and 15= -17dbrw INTEGER .1.3.6.1.4.1.1166.6.1.2.29.3.2.40 |
rx4stateFlagSwModeThresholdTwoThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.41 |
rx4labelModeThreeThe value of this object provides the label of the
Rx200BX4's Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.42 |
rx4enumModeThreeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.43 |
rx4valueModeThreeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.44 |
rx4stateFlagModeThreeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.45 |
rx4labelWavelengthThreeThe value of this object provides the label of the
Rx200BX4's Wavelength Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.46 |
rx4enumWavelengthThreeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.47 |
rx4valueWavelengthThreeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.48 |
rx4stateFlagWavelengthThreeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.49 |
rx4labelAttnSettingThreeThe value of this object provides the label of the
Rx200BX4's AttnSetting Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.50 |
rx4enumAttnSettingThreeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.51 |
rx4valueAttnSettingThreeThe value of this object is the current value of the parameter. It is an integer
value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB.
Where 0 = 0db and 40 = 20dbrw INTEGER .1.3.6.1.4.1.1166.6.1.2.29.3.2.52 |
rx4stateFlagAttnSettingThreeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.53 |
rx4labelSwModeSettingThreeThe value of this object provides the label of the
Rx200BX4's Switch Mode Setting Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.54 |
rx4enumSwModeSettingThreeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.55 |
rx4valueSwModeSettingThreeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.56 |
rx4stateFlagSwModeSettingThreeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.57 |
rx4labelSwModeThresholdThreeThe value of this object provides the label of the
Rx200BX4's Switch Mode Threshold Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.58 |
rx4enumSwModeThresholdThreeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.59 |
rx4valueSwModeThresholdThreeThe value of this object reflects the setting of the threshold at
which the Optical Input Failed signal is sent. It is in 1 dB increments
ranging from -2 to -17 dB. The user can enter a number from 0 to 15,
where 0 = -2db and 15= -17dbrw INTEGER .1.3.6.1.4.1.1166.6.1.2.29.3.2.60 |
rx4stateFlagSwModeThresholdThreeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.61 |
rx4labelModeFourThe value of this object provides the label of the
Rx200BX4's Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.62 |
rx4enumModeFourThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.63 |
rx4valueModeFourThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.64 |
rx4stateFlagModeFourThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.65 |
rx4labelWavelengthFourThe value of this object provides the label of the
Rx200BX4's Wavelength Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.66 |
rx4enumWavelengthFourThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.67 |
rx4valueWavelengthFourThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.68 |
rx4stateFlagWavelengthFourThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.69 |
rx4labelAttnSettingFourThe value of this object provides the label of the
Rx200BX4's AttnSetting Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.70 |
rx4enumAttnSettingFourThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.71 |
rx4valueAttnSettingFourThe value of this object is the current value of the parameter. It is an integer
value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB.
Where 0 = 0db and 40 = 20dbrw INTEGER .1.3.6.1.4.1.1166.6.1.2.29.3.2.72 |
rx4stateFlagAttnSettingFourThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.73 |
rx4labelSwModeSettingFourThe value of this object provides the label of the
Rx200BX4's Switch Mode Setting Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.74 |
rx4enumSwModeSettingFourThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.75 |
rx4valueSwModeSettingFourThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.76 |
rx4stateFlagSwModeSettingFourThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.77 |
rx4labelSwModeThresholdFourThe value of this object provides the label of the
Rx200BX4's Switch Mode Threshold Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.78 |
rx4enumSwModeThresholdFourThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.79 |
rx4valueSwModeThresholdFourThe value of this object reflects the setting of the threshold at
which the Optical Input Failed signal is sent. It is in 1 dB increments
ranging from -2 to -17 dB. The user can enter a number from 0 to 15,
where 0 = -2db and 15= -17dbrw INTEGER .1.3.6.1.4.1.1166.6.1.2.29.3.2.80 |
rx4stateFlagSwModeThresholdFourThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.81 |
rx4labelModuleConfigThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.82 |
rx4enumModuleConfigThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.83 |
rx4valueModuleConfigThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.84 |
rx4stateFlagModuleConfigThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.85 |
rx4labelRevertTimeThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.86 |
rx4enumRevertTimeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.87 |
rx4valueRevertTimeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.88 |
rx4stateFlagRevertTimeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.89 |
rx4labelTestPointSelectThe value of this object provides the label of the
Test point Select Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.90 |
rx4enumTestPointSelectThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.91 |
rx4valueTestPointSelectThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.92 |
rx4stateFlagTestPointSelectThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.93 |
rx4labelFactoryDefaultThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.94 |
rx4enumFactoryDefaultThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.3.2.95 |
rx4valueFactoryDefaultThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.96 |
rx4stateFlagFactoryDefaultThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.3.2.97 |
gx2Rx200BX4StatusTableThis table contains gx2Rx200BX4 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rx200BX4StatusEntry .1.3.6.1.4.1.1166.6.1.2.29.4 |
gx2Rx200BX4StatusEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rx200BX4StatusEntry .1.3.6.1.4.1.1166.6.1.2.29.4.3 |
gx2Rx200BX4StatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.4.3.1 |
rx4labelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.2 |
rx4valueBootThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.3 |
rx4stateflagBootThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.4 |
rx4labelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.5 |
rx4valueFlashThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.6 |
rx4stateflagFlashThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.7 |
rx4labelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.8 |
rx4valueFactoryDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.9 |
rx4stateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.10 |
rx4labelAlarmDataCRCThe value of this object provides the label of the
Alarm Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.11 |
rx4valueAlarmDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.12 |
rx4stateflagAlarmDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.13 |
rx4labelCalibrationDataCRCThe value of this object provides the label of the
Calibration Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.14 |
rx4valueCalibrationDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.15 |
rx4stateflagCalibrationDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.16 |
rx4labelHWThe value of this object provides the label of the
Hardware Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.17 |
rx4valueHWThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.18 |
rx4stateflagHWThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.19 |
rx4labelOptSigOneThe value of this object provides the label of the
Optical Signal Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.20 |
rx4valueOptSigOneThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.21 |
rx4stateflagOptSigOneThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.22 |
rx4labelOptSigTwoThe value of this object provides the label of the
Optical Signal Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.23 |
rx4valueOptSigTwoThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.24 |
rx4stateflagOptSigTwoThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.25 |
rx4labelOptSigThreeThe value of this object provides the label of the
Optical Signal Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.26 |
rx4valueOptSigThreeThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.27 |
rx4stateflagOptSigThreeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.28 |
rx4labelOptSigFourThe value of this object provides the label of the
Optical Signal Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.29 |
rx4valueOptSigFourThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.30 |
rx4stateflagOptSigFourThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.31 |
rx4labelBackupCableThe value of this object provides the label of the
Backup Cable Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.4.3.32 |
rx4valueBackupCableThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.33 |
rx4stateflagBackupCableThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.4.3.34 |
gx2Rx200BX4FactoryTableThis table contains gx2Rx200BX4 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rx200BX4FactoryEntry .1.3.6.1.4.1.1166.6.1.2.29.5 |
gx2Rx200BX4FactoryEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rx200BX4FactoryEntry .1.3.6.1.4.1.1166.6.1.2.29.5.4 |
gx2Rx200BX4FactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.5.4.1 |
rx4bootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.5.4.2 |
rx4bootStatusByteThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.5.4.3 |
rx4bank0CRCThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.5.4.4 |
rx4bank1CRCThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.5.4.5 |
rx4prgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.5.4.6 |
rx4factoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.5.4.7 |
rx4calculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.29.5.4.8 |
rx4hourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.5.4.9 |
rx4flashPrgCntAThis object provides the number of times the flash has been
programmed on side A.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.5.4.10 |
rx4flashPrgCntBThis object provides the number of times the flash has been
programmed on side B.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.29.5.4.11 |
rx4fwRev0This object provides the Revision of the firmware stores in bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.5.4.12 |
rx4fwRev1This object provides the Revision of the firmware stores in bank 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.29.5.4.13 |