Home/Catalog/OMNI-gx2Rx085BX4-MIB

OMNI-gx2Rx085BX4-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for OMNI-gx2Rx085BX4-MIB.

265
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

265 total
Object Name
trapRx085BX4ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.1
trapRx085BX4ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.2
trapRx085BX4OpticalPower1AlarmThis trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.3
trapRx085BX4OpticalPower2AlarmThis trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.4
trapRx085BX4OpticalPower3AlarmThis trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.5
trapRx085BX4OpticalPower4AlarmThis trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.6
trapRx085BX4ModuleTemperatureAlarmThis trap is issued when the Rx085BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.7
trapRx085BX4FanCurrentAlarmThis trap is issued when the Rx085BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.8
trapRx085BX4Plus12CurrentAlarmThis trap is issued when the Rx085BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.9
trapRx085BX4Boot0AlarmThis trap is issued when the Rx085BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.10
trapRx085BX4Boot1AlarmThis trap is issued when the Rx085BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.11
trapRx085BX4FlashAlarmThis trap is issued when the Rx085BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.12
trapRx085BX4AlarmDataCRCAlarmThis trap is issued when the Rx085BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.13
trapRx085BX4FactoryDataCRCAlarmThis trap is issued when the Rx085BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.14
trapRx085BX4CalDataCRCAlarmThis trap is issued when the Rx085BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.15
trapRx085BX4DefaultAlarmThis trap is issued when the Rx085BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.16
trapRx085BX4Mode1AlarmThis trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.17
trapRx085BX4Mode2AlarmThis trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.18
trapRx085BX4Mode3AlarmThis trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.19
trapRx085BX4Mode4AlarmThis trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.20
trapRx085BX4Output1SwitchedAlarmThis trap is issued when the Rx085BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.21
trapRx085BX4Output2SwitchedAlarmThis trap is issued when the Rx085BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.22
trapRx085BX4Output3SwitchedAlarmThis trap is issued when the Rx085BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.23
trapRx085BX4Output4SwitchedAlarmThis trap is issued when the Rx085BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.24
trapRx085BX4RX1StatusAlarmThis trap is issued when receiver 1 of the Rx085BX4 Module output is turned on or off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.25
trapRx085BX4RX2StatusAlarmThis trap is issued when receiver 2 of the Rx085BX4 Module output is turned on or off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.26
trapRx085BX4RX3StatusAlarmThis trap is issued when receiver 3 of the Rx085BX4 Module output is turned on or off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.27
trapRx085BX4RX4StatusAlarmThis trap is issued when receiver 4 of the Rx085BX4 Module output is turned on or off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.28
trapRx085BX4BackupCableAlarmThis trap is issued when the slave receiver loses connection to the master receiver.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.29
trapRx085BX4OptPwr1BadAlarmThis trap is issued when the receiver 1 optical power level falls below the user set switching threshold.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.30
trapRx085BX4OptPwr2BadAlarmThis trap is issued when the receiver 2 optical power level falls below the user set switching threshold.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.31
trapRx085BX4OptPwr3BadAlarmThis trap is issued when the receiver 3 optical power level falls below the user set switching threshold.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.32
trapRx085BX4OptPwr4BadAlarmThis trap is issued when the receiver 4 optical power level falls below the user set switching threshold.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.32.0.33
gx2Rx085BX4Descriptor
OBJECT IDENTIFIER
.1.3.6.1.4.1.1166.6.1.2.32.1
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1166.6.1.2.32.1
gx2Rx085BX4AnalogTableThis table contains gx2Rx085BX4 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx085BX4AnalogEntry
.1.3.6.1.4.1.1166.6.1.2.32.2
gx2Rx085BX4AnalogEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx085BX4AnalogEntry
.1.3.6.1.4.1.1166.6.1.2.32.2.1
gx2Rx085BX4AnalogTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.2.1.1
rx085labelOptPowerOneThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.2
rx085uomOptPowerOneThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.3
rx085majorHighOptPowerOneThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.4
rx085majorLowOptPowerOneThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.5
rx085minorHighOptPowerOneThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.6
rx085minorLowOptPowerOneThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.7
rx085currentValueOptPowerOneThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.8
rx085stateFlagOptPowerOneThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.9
rx085minValueOptPowerOneThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.10
rx085maxValueOptPowerOneThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.11
rx085alarmStateOptPowerOneThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.12
rx085labelOptPowerTwoThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.13
rx085uomOptPowerTwoThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.14
rx085majorHighOptPowerTwoThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.15
rx085majorLowOptPowerTwoThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.16
rx085minorHighOptPowerTwoThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.17
rx085minorLowOptPowerTwoThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.18
rx085currentValueOptPowerTwoThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.19
rx085stateFlagOptPowerTwoThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.20
rx085minValueOptPowerTwoThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.21
rx085maxValueOptPowerTwoThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.22
rx085alarmStateOptPowerTwoThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.23
rx085labelOptPowerThreeThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.24
rx085uomOptPowerThreeThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.25
rx085majorHighOptPowerThreeThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.26
rx085majorLowOptPowerThreeThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.27
rx085minorHighOptPowerThreeThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.28
rx085minorLowOptPowerThreeThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.29
rx085currentValueOptPowerThreeThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.30
rx085stateFlagOptPowerThreeThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.31
rx085minValueOptPowerThreeThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.32
rx085maxValueOptPowerThreeThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.33
rx085alarmStateOptPowerThreeThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.34
rx085labelOptPowerFourThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.35
rx085uomOptPowerFourThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.36
rx085majorHighOptPowerFourThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.37
rx085majorLowOptPowerFourThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.38
rx085minorHighOptPowerFourThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.39
rx085minorLowOptPowerFourThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.40
rx085currentValueOptPowerFourThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.41
rx085stateFlagOptPowerFourThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.42
rx085minValueOptPowerFourThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.43
rx085maxValueOptPowerFourThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.44
rx085alarmStateOptPowerFourThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.45
rx085labelModTempThe value of this object provides the label of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.46
rx085uomModTempThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.47
rx085majorHighModTempThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.48
rx085majorLowModTempThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.49
rx085minorHighModTempThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.50
rx085minorLowModTempThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.51
rx085currentValueModTempThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.52
rx085stateFlagModTempThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.53
rx085minValueModTempThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.54
rx085maxValueModTempThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.55
rx085alarmStateModTempThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.56
rx085labelFanCurrentThe value of this object provides the label of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.57
rx085uomFanCurrentThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.58
rx085majorHighFanCurrentThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.59
rx085majorLowFanCurrentThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.60
rx085minorHighFanCurrentThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.61
rx085minorLowFanCurrentThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.62
rx085currentValueFanCurrentThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.63
rx085stateFlagFanCurrentThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.64
rx085minValueFanCurrentThe value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.65
rx085maxValueFanCurrentThe value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.66
rx085alarmStateFanCurrentThe value of this object provides the curent alarm state of the Fan Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.67
rx085label12VoltThe value of this object provides the label of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.68
rx085uom12VoltThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.2.1.69
rx085majorHigh12VoltThe value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.70
rx085majorLow12VoltThe value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.71
rx085minorHigh12VoltThe value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.72
rx085minorLow12VoltThe value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.73
rx085currentValue12VoltThe value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.74
rx085stateFlag12VoltThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.75
rx085minValue12VoltThe value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.76
rx085maxValue12VoltThe value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.32.2.1.77
rx085alarmState12VoltThe value of this object provides the curent alarm state of the 12v Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.2.1.78
gx2Rx085BX4DigitalTableThis table contains gx2Rx085BX4 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx085BX4DigitalEntry
.1.3.6.1.4.1.1166.6.1.2.32.3
gx2Rx085BX4DigitalEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx085BX4DigitalEntry
.1.3.6.1.4.1.1166.6.1.2.32.3.2
gx2Rx085BX4DigitalTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.3.2.1
rx085labelModeOneThe value of this object provides the label of the Rx085BX4's Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.2
rx085enumModeOneThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.3
rx085valueModeOneThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.4
rx085stateFlagModeOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.5
rx085labelWavelengthOneThe value of this object provides the label of the Rx085BX4's Wavelength Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.6
rx085enumWavelengthOneThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.7
rx085valueWavelengthOneThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.8
rx085stateFlagWavelengthOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.9
rx085labelAttnSettingOneThe value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.10
rx085enumAttnSettingOneThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.11
rx085valueAttnSettingOneThe value of this object is the current value of the parameter. It is an integer value from 0 to 60. Each increment represents 1/2 dB of attenuation from 0 to 30 dB. Where 0 = 0db and 60 = 30dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.3.2.12
rx085stateFlagAttnSettingOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.13
rx085labelSwModeSettingOneThe value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.14
rx085enumSwModeSettingOneThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.15
rx085valueSwModeSettingOneThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.16
rx085stateFlagSwModeSettingOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.17
rx085labelSwModeThresholdOneThe value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.18
rx085enumSwModeThresholdOneThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.19
rx085valueSwModeThresholdOneThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.3.2.20
rx085stateFlagSwModeThresholdOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.21
rx085labelModeTwoThe value of this object provides the label of the Rx085BX4's Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.22
rx085enumModeTwoThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.23
rx085valueModeTwoThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.24
rx085stateFlagModeTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.25
rx085labelWavelengthTwoThe value of this object provides the label of the Rx085BX4's Wavelength Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.26
rx085enumWavelengthTwoThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.27
rx085valueWavelengthTwoThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.28
rx085stateFlagWavelengthTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.29
rx085labelAttnSettingTwoThe value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.30
rx085enumAttnSettingTwoThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.31
rx085valueAttnSettingTwoThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.3.2.32
rx085stateFlagAttnSettingTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.33
rx085labelSwModeSettingTwoThe value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.34
rx085enumSwModeSettingTwoThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.35
rx085valueSwModeSettingTwoThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.36
rx085stateFlagSwModeSettingTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.37
rx085labelSwModeThresholdTwoThe value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.38
rx085enumSwModeThresholdTwoThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.39
rx085valueSwModeThresholdTwoThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.3.2.40
rx085stateFlagSwModeThresholdTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.41
rx085labelModeThreeThe value of this object provides the label of the Rx085BX4's Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.42
rx085enumModeThreeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.43
rx085valueModeThreeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.44
rx085stateFlagModeThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.45
rx085labelWavelengthThreeThe value of this object provides the label of the Rx085BX4's Wavelength Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.46
rx085enumWavelengthThreeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.47
rx085valueWavelengthThreeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.48
rx085stateFlagWavelengthThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.49
rx085labelAttnSettingThreeThe value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.50
rx085enumAttnSettingThreeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.51
rx085valueAttnSettingThreeThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.3.2.52
rx085stateFlagAttnSettingThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.53
rx085labelSwModeSettingThreeThe value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.54
rx085enumSwModeSettingThreeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.55
rx085valueSwModeSettingThreeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.56
rx085stateFlagSwModeSettingThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.57
rx085labelSwModeThresholdThreeThe value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.58
rx085enumSwModeThresholdThreeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.59
rx085valueSwModeThresholdThreeThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.3.2.60
rx085stateFlagSwModeThresholdThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.61
rx085labelModeFourThe value of this object provides the label of the Rx085BX4's Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.62
rx085enumModeFourThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.63
rx085valueModeFourThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.64
rx085stateFlagModeFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.65
rx085labelWavelengthFourThe value of this object provides the label of the Rx085BX4's Wavelength Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.66
rx085enumWavelengthFourThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.67
rx085valueWavelengthFourThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.68
rx085stateFlagWavelengthFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.69
rx085labelAttnSettingFourThe value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.70
rx085enumAttnSettingFourThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.71
rx085valueAttnSettingFourThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.3.2.72
rx085stateFlagAttnSettingFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.73
rx085labelSwModeSettingFourThe value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.74
rx085enumSwModeSettingFourThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.75
rx085valueSwModeSettingFourThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.76
rx085stateFlagSwModeSettingFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.77
rx085labelSwModeThresholdFourThe value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.78
rx085enumSwModeThresholdFourThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.79
rx085valueSwModeThresholdFourThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.3.2.80
rx085stateFlagSwModeThresholdFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.81
rx085labelModuleConfigThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.82
rx085enumModuleConfigThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.83
rx085valueModuleConfigThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.84
rx085stateFlagModuleConfigThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.85
rx085labelRevertTimeThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.86
rx085enumRevertTimeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.87
rx085valueRevertTimeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.88
rx085stateFlagRevertTimeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.89
rx085labelTestPointSelectThe value of this object provides the label of the Test point Select Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.90
rx085enumTestPointSelectThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.91
rx085valueTestPointSelectThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.92
rx085stateFlagTestPointSelectThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.93
rx085labelFactoryDefaultThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.94
rx085enumFactoryDefaultThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.3.2.95
rx085valueFactoryDefaultThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.96
rx085stateFlagFactoryDefaultThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.3.2.97
gx2Rx085BX4StatusTableThis table contains gx2Rx085BX4 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx085BX4StatusEntry
.1.3.6.1.4.1.1166.6.1.2.32.4
gx2Rx085BX4StatusEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx085BX4StatusEntry
.1.3.6.1.4.1.1166.6.1.2.32.4.3
gx2Rx085BX4StatusTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.4.3.1
rx085labelBootThe value of this object provides the label of the Boot Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.2
rx085valueBootThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.3
rx085stateflagBootThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.4
rx085labelFlashThe value of this object provides the label of the Flash Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.5
rx085valueFlashThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.6
rx085stateflagFlashThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.7
rx085labelFactoryDataCRCThe value of this object provides the label of the Factory Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.8
rx085valueFactoryDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.9
rx085stateflagFactoryDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.10
rx085labelAlarmDataCRCThe value of this object provides the label of the Alarm Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.11
rx085valueAlarmDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.12
rx085stateflagAlarmDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.13
rx085labelCalibrationDataCRCThe value of this object provides the label of the Calibration Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.14
rx085valueCalibrationDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.15
rx085stateflagCalibrationDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.16
rx085labelHWThe value of this object provides the label of the Hardware Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.17
rx085valueHWThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.18
rx085stateflagHWThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.19
rx085labelOptSigOneThe value of this object provides the label of the Optical Signal Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.20
rx085valueOptSigOneThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.21
rx085stateflagOptSigOneThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.22
rx085labelOptSigTwoThe value of this object provides the label of the Optical Signal Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.23
rx085valueOptSigTwoThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.24
rx085stateflagOptSigTwoThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.25
rx085labelOptSigThreeThe value of this object provides the label of the Optical Signal Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.26
rx085valueOptSigThreeThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.27
rx085stateflagOptSigThreeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.28
rx085labelOptSigFourThe value of this object provides the label of the Optical Signal Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.29
rx085valueOptSigFourThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.30
rx085stateflagOptSigFourThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.31
rx085labelBackupCableThe value of this object provides the label of the Backup Cable Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.4.3.32
rx085valueBackupCableThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.33
rx085stateflagBackupCableThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.4.3.34
gx2Rx085BX4FactoryTableThis table contains gx2Rx085BX4 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx085BX4FactoryEntry
.1.3.6.1.4.1.1166.6.1.2.32.5
gx2Rx085BX4FactoryEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx085BX4FactoryEntry
.1.3.6.1.4.1.1166.6.1.2.32.5.4
gx2Rx085BX4FactoryTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.5.4.1
rx085bootControlByteThe value of this object indicates which bank the firmware is currently being boot from.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.5.4.2
rx085bootStatusByteThis object indicates the status of the last bootro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.5.4.3
rx085bank0CRCThis object provides the CRC code of bank 0.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.5.4.4
rx085bank1CRCThis object provides the CRC code of bank 1.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.5.4.5
rx085prgEEPROMByteThis object indicates if the EEPROM has been programmedro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.5.4.6
rx085factoryCRCThis object provides the CRC code for the Factory data.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.5.4.7
rx085calculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.32.5.4.8
rx085hourMeterThis object provides the hour meter reading of the module.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.5.4.9
rx085flashPrgCntAThis object provides the number of times the flash has been programmed on side A.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.5.4.10
rx085flashPrgCntBThis object provides the number of times the flash has been programmed on side B.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.32.5.4.11
rx085fwRev0This object provides the Revision of the firmware stores in bank 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.5.4.12
rx085fwRev1This object provides the Revision of the firmware stores in bank 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.32.5.4.13