OMNI-gx2litePS-MIB
Standard SNMP MIB module defining data structures for OMNI-gx2litePS-MIB.
Imported Objects
Objects
54 total| Object Name |
|---|
trapLitepsConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.1 |
trapLitepsConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.2 |
trapLitepsFanCurrent1This trap is issued when Fan 1 is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.3 |
trapLitepsFanCurrent2This trap is issued when Fan 2 is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.4 |
trapLiteps12VoltThis trap is issued when the 12 Volts is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.5 |
trapLiteps5VoltThis trap is issued when the 5.1 Volts is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.6 |
trapLiteps3VoltThis trap is issued when the 3.7 Volts is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.7 |
gx2LitepsDescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.23.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.23.1 |
gx2LitepsAnalogTableThis table contains gx2Liteps specific parameters with
nominal and current values. SEQUENCE OF Gx2LitepsAnalogEntry .1.3.6.1.4.1.1166.6.1.2.23.2 |
gx2LitepsAnalogEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2LitepsAnalogEntry .1.3.6.1.4.1.1166.6.1.2.23.2.1 |
gx2LitepsAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.23.2.1.1 |
litepslabel12VoltThe value of this object provides the label of the 12 Volt Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.2 |
litepsuom12VoltThe value of this object provides the unit of measure of the 12 Volt
Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.3 |
litepsmajorHigh12VoltThe value of this object provides the Major High alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.4 |
litepsmajorLow12VoltThe value of this object provides the Major Low alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.5 |
litepsminorHigh12VoltThe value of this object provides the Minor High alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.6 |
litepsminorLow12VoltThe value of this object provides the Minor Low alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.7 |
litepscurrentValue12VoltThe value of this object provides the Current value of the 12 Volt Analog
parameter. This value is a floating point number that is represented as an
IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.8 |
litepsstateFlag12VoltThe value of this object provides the state of the 12 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable)ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.9 |
litepsminValue12VoltThe value of this object provides the minimum value the 12 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.10 |
litepsmaxValue12VoltThe value of this object provides the maximum value the 12 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.11 |
litepsalarmState12VoltThe value of this object provides the curent alarm state of the 12 Volt Analog
parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.12 |
litepslabel5VoltThe value of this object provides the label of the Attenuator Setting Analog
parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.13 |
litepsuom5VoltThe value of this object provides the Unit of Measure of the 5 Volt Analog
parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.14 |
litepsmajorHigh5VoltThe value of this object provides the Major High alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.15 |
litepsmajorLow5VoltThe value of this object provides the Major Low alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.16 |
litepsminorHigh5VoltThe value of this object provides the Minor High alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.17 |
litepsminorLow5VoltThe value of this object provides the Minor Low alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.18 |
litepscurrentValue5VoltThe value of this object provides the Current value of the 5 Volt Analog
parameter. This value is a floating point number that is represented as
an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.19 |
litepsstateFlag5VoltThe value of this object provides the state of the 5 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.20 |
litepsminValue5VoltThe value of this object provides the minimum value the 5 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.21 |
litepsmaxValue5VoltThe value of this object provides the maximum value the 5 Volt Analog parameter
can achieve. This value is a floating point number that is represented as an
IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.22 |
litepsalarmState5VoltThe value of this object provides the curent alarm state of the 5 Volt
Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.23 |
litepslabel3VoltThe value of this object provides the label of the
3 Anode Volt Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.24 |
litepsuom3VoltThe value of this object provides the Unit of Measure of the 3.7V anode voltage
analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.25 |
litepsmajorHigh3VoltThe value of this object provides the Major High alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.26 |
litepsmajorLow3VoltThe value of this object provides the Major Low alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.27 |
litepsminorHigh3VoltThe value of this object provides the Minor High alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.28 |
litepsminorLow3VoltThe value of this object provides the Minor Low alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.29 |
litepscurrentValue3VoltThe value of this object provides the Current value of the 3.7V anode voltage
analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.30 |
litepsstateFlag3VoltThe value of this object provides the state of the 3 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.31 |
litepsminValue3VoltThe value of this object provides the minimum value that the 3.7V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.32 |
litepsmaxValue3VoltThe value of this object provides the maximum value that the 3.7V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.33 |
litepsalarmState3VoltThe value of this object provides the curent alarm state of the 3.7V anode
voltage analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.34 |
gx2LitepsStatusTableThis table contains gx2Liteps specific parameters with
nominal and current values. SEQUENCE OF Gx2LitepsStatusEntry .1.3.6.1.4.1.1166.6.1.2.23.3 |
gx2LitepsStatusEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2LitepsStatusEntry .1.3.6.1.4.1.1166.6.1.2.23.3.2 |
gx2LitepsStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.23.3.2.1 |
litepslabelFan1StatusThe value of this object provides the label of the
Fan 1 Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.3.2.2 |
litepsvalueFan1StatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.3.2.3 |
litepsstateflagFan1StatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.3.2.4 |
litepslabelFan2StatusThe value of this object provides the label of the
Fan 2 Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.3.2.5 |
litepsvalueFan2StatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.3.2.6 |
litepsstateflagFan2StatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.3.2.7 |
More MIBs from Gi M I B
Browse all Gi M I BMIBs →The APEX-MIB module facilitates the monitoring and management of Cisco Catalyst 9000 series switches, specifically those utilizing the APEX (Advanced Platform for Enterprise eXchange) architecture, by exposing standardized SNMP objects for interface statistics, system resources, and hardware health. This MIB enables network administrators to track real-time performance metrics, including port throughput, error counters, temperature readings, and power supply status, to ensure operational stability and facilitate troubleshooting within the Cisco enterprise switching environment.
Standard SNMP MIB module defining data structures for OMNI-gx2dualdrr2x-MIB.
SNMP MIB module
Standard SNMP MIB module defining data structures for OMNI-gx2EDFA-MIB.
Standard SNMP MIB module defining data structures for OMNI-gx2Rx085BX4-MIB.
SNMP MIB module