OMNI-gx2litePS-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for OMNI-gx2litePS-MIB.
54
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
54 total| Object Name |
|---|
trapLitepsConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.1 |
trapLitepsConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.2 |
trapLitepsFanCurrent1This trap is issued when Fan 1 is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.3 |
trapLitepsFanCurrent2This trap is issued when Fan 2 is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.4 |
trapLiteps12VoltThis trap is issued when the 12 Volts is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.5 |
trapLiteps5VoltThis trap is issued when the 5.1 Volts is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.6 |
trapLiteps3VoltThis trap is issued when the 3.7 Volts is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.23.0.7 |
gx2LitepsDescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.23.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.23.1 |
gx2LitepsAnalogTableThis table contains gx2Liteps specific parameters with
nominal and current values. SEQUENCE OF Gx2LitepsAnalogEntry .1.3.6.1.4.1.1166.6.1.2.23.2 |
gx2LitepsAnalogEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2LitepsAnalogEntry .1.3.6.1.4.1.1166.6.1.2.23.2.1 |
gx2LitepsAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.23.2.1.1 |
litepslabel12VoltThe value of this object provides the label of the 12 Volt Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.2 |
litepsuom12VoltThe value of this object provides the unit of measure of the 12 Volt
Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.3 |
litepsmajorHigh12VoltThe value of this object provides the Major High alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.4 |
litepsmajorLow12VoltThe value of this object provides the Major Low alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.5 |
litepsminorHigh12VoltThe value of this object provides the Minor High alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.6 |
litepsminorLow12VoltThe value of this object provides the Minor Low alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.7 |
litepscurrentValue12VoltThe value of this object provides the Current value of the 12 Volt Analog
parameter. This value is a floating point number that is represented as an
IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.8 |
litepsstateFlag12VoltThe value of this object provides the state of the 12 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable)ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.9 |
litepsminValue12VoltThe value of this object provides the minimum value the 12 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.10 |
litepsmaxValue12VoltThe value of this object provides the maximum value the 12 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.11 |
litepsalarmState12VoltThe value of this object provides the curent alarm state of the 12 Volt Analog
parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.12 |
litepslabel5VoltThe value of this object provides the label of the Attenuator Setting Analog
parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.13 |
litepsuom5VoltThe value of this object provides the Unit of Measure of the 5 Volt Analog
parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.14 |
litepsmajorHigh5VoltThe value of this object provides the Major High alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.15 |
litepsmajorLow5VoltThe value of this object provides the Major Low alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.16 |
litepsminorHigh5VoltThe value of this object provides the Minor High alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.17 |
litepsminorLow5VoltThe value of this object provides the Minor Low alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.18 |
litepscurrentValue5VoltThe value of this object provides the Current value of the 5 Volt Analog
parameter. This value is a floating point number that is represented as
an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.19 |
litepsstateFlag5VoltThe value of this object provides the state of the 5 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.20 |
litepsminValue5VoltThe value of this object provides the minimum value the 5 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.21 |
litepsmaxValue5VoltThe value of this object provides the maximum value the 5 Volt Analog parameter
can achieve. This value is a floating point number that is represented as an
IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.22 |
litepsalarmState5VoltThe value of this object provides the curent alarm state of the 5 Volt
Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.23 |
litepslabel3VoltThe value of this object provides the label of the
3 Anode Volt Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.24 |
litepsuom3VoltThe value of this object provides the Unit of Measure of the 3.7V anode voltage
analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.2.1.25 |
litepsmajorHigh3VoltThe value of this object provides the Major High alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.26 |
litepsmajorLow3VoltThe value of this object provides the Major Low alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.27 |
litepsminorHigh3VoltThe value of this object provides the Minor High alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.28 |
litepsminorLow3VoltThe value of this object provides the Minor Low alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.29 |
litepscurrentValue3VoltThe value of this object provides the Current value of the 3.7V anode voltage
analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.30 |
litepsstateFlag3VoltThe value of this object provides the state of the 3 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.31 |
litepsminValue3VoltThe value of this object provides the minimum value that the 3.7V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.32 |
litepsmaxValue3VoltThe value of this object provides the maximum value that the 3.7V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.23.2.1.33 |
litepsalarmState3VoltThe value of this object provides the curent alarm state of the 3.7V anode
voltage analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.2.1.34 |
gx2LitepsStatusTableThis table contains gx2Liteps specific parameters with
nominal and current values. SEQUENCE OF Gx2LitepsStatusEntry .1.3.6.1.4.1.1166.6.1.2.23.3 |
gx2LitepsStatusEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2LitepsStatusEntry .1.3.6.1.4.1.1166.6.1.2.23.3.2 |
gx2LitepsStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.23.3.2.1 |
litepslabelFan1StatusThe value of this object provides the label of the
Fan 1 Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.3.2.2 |
litepsvalueFan1StatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.3.2.3 |
litepsstateflagFan1StatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.3.2.4 |
litepslabelFan2StatusThe value of this object provides the label of the
Fan 2 Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.23.3.2.5 |
litepsvalueFan2StatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.3.2.6 |
litepsstateflagFan2StatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.23.3.2.7 |