Home/Catalog/OMNI-gx2litePS-MIB

OMNI-gx2litePS-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for OMNI-gx2litePS-MIB.

54
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

54 total
Object Name
trapLitepsConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.23.0.1
trapLitepsConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.23.0.2
trapLitepsFanCurrent1This trap is issued when Fan 1 is in an alarm condition.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.23.0.3
trapLitepsFanCurrent2This trap is issued when Fan 2 is in an alarm condition.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.23.0.4
trapLiteps12VoltThis trap is issued when the 12 Volts is in an alarm condition.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.23.0.5
trapLiteps5VoltThis trap is issued when the 5.1 Volts is in an alarm condition.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.23.0.6
trapLiteps3VoltThis trap is issued when the 3.7 Volts is in an alarm condition.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.23.0.7
gx2LitepsDescriptor
OBJECT IDENTIFIER
.1.3.6.1.4.1.1166.6.1.2.23.1
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1166.6.1.2.23.1
gx2LitepsAnalogTableThis table contains gx2Liteps specific parameters with nominal and current values.
SEQUENCE OF Gx2LitepsAnalogEntry
.1.3.6.1.4.1.1166.6.1.2.23.2
gx2LitepsAnalogEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2LitepsAnalogEntry
.1.3.6.1.4.1.1166.6.1.2.23.2.1
gx2LitepsAnalogTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.23.2.1.1
litepslabel12VoltThe value of this object provides the label of the 12 Volt Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.23.2.1.2
litepsuom12VoltThe value of this object provides the unit of measure of the 12 Volt Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.23.2.1.3
litepsmajorHigh12VoltThe value of this object provides the Major High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.4
litepsmajorLow12VoltThe value of this object provides the Major Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.5
litepsminorHigh12VoltThe value of this object provides the Minor High alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.6
litepsminorLow12VoltThe value of this object provides the Minor Low alarm value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.7
litepscurrentValue12VoltThe value of this object provides the Current value of the 12 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.8
litepsstateFlag12VoltThe value of this object provides the state of the 12 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.23.2.1.9
litepsminValue12VoltThe value of this object provides the minimum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.10
litepsmaxValue12VoltThe value of this object provides the maximum value the 12 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.11
litepsalarmState12VoltThe value of this object provides the curent alarm state of the 12 Volt Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.23.2.1.12
litepslabel5VoltThe value of this object provides the label of the Attenuator Setting Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.23.2.1.13
litepsuom5VoltThe value of this object provides the Unit of Measure of the 5 Volt Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.23.2.1.14
litepsmajorHigh5VoltThe value of this object provides the Major High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.15
litepsmajorLow5VoltThe value of this object provides the Major Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.16
litepsminorHigh5VoltThe value of this object provides the Minor High alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.17
litepsminorLow5VoltThe value of this object provides the Minor Low alarm value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.18
litepscurrentValue5VoltThe value of this object provides the Current value of the 5 Volt Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.19
litepsstateFlag5VoltThe value of this object provides the state of the 5 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.23.2.1.20
litepsminValue5VoltThe value of this object provides the minimum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.21
litepsmaxValue5VoltThe value of this object provides the maximum value the 5 Volt Analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.22
litepsalarmState5VoltThe value of this object provides the curent alarm state of the 5 Volt Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.23.2.1.23
litepslabel3VoltThe value of this object provides the label of the 3 Anode Volt Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.23.2.1.24
litepsuom3VoltThe value of this object provides the Unit of Measure of the 3.7V anode voltage analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.23.2.1.25
litepsmajorHigh3VoltThe value of this object provides the Major High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.26
litepsmajorLow3VoltThe value of this object provides the Major Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.27
litepsminorHigh3VoltThe value of this object provides the Minor High alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.28
litepsminorLow3VoltThe value of this object provides the Minor Low alarm value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.29
litepscurrentValue3VoltThe value of this object provides the Current value of the 3.7V anode voltage analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.30
litepsstateFlag3VoltThe value of this object provides the state of the 3 Volt Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.23.2.1.31
litepsminValue3VoltThe value of this object provides the minimum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.32
litepsmaxValue3VoltThe value of this object provides the maximum value that the 3.7V anode voltage analog parameter can achieve. This value is a floating point number that is represented as an IEEE 32 Bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.23.2.1.33
litepsalarmState3VoltThe value of this object provides the curent alarm state of the 3.7V anode voltage analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.23.2.1.34
gx2LitepsStatusTableThis table contains gx2Liteps specific parameters with nominal and current values.
SEQUENCE OF Gx2LitepsStatusEntry
.1.3.6.1.4.1.1166.6.1.2.23.3
gx2LitepsStatusEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2LitepsStatusEntry
.1.3.6.1.4.1.1166.6.1.2.23.3.2
gx2LitepsStatusTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.23.3.2.1
litepslabelFan1StatusThe value of this object provides the label of the Fan 1 Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.23.3.2.2
litepsvalueFan1StatusThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.23.3.2.3
litepsstateflagFan1StatusThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.23.3.2.4
litepslabelFan2StatusThe value of this object provides the label of the Fan 2 Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.23.3.2.5
litepsvalueFan2StatusThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.23.3.2.6
litepsstateflagFan2StatusThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.23.3.2.7
OMNI-gx2litePS-MIB - SNMP MIB Reference | MIBs Explorer