OMNI-gx2drr4x-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
173
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
173 total| Object Name |
|---|
trapdrrConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.1 |
trapdrrConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.2 |
trapdrr12VCurrentAlarmThis trap is issued when the 12V power supply Current
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.3 |
trapdrrModuleTempAlarmThis trap is issued when the Internal Module Temperature goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.4 |
trapdrrFanCurrentAlarmThis trap is issued when the Fan Current
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.5 |
trapdrrFlashAlarmThis trap is issued when the detects an error during
Flash memory operations. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.6 |
trapdrrBankBootAlarmThis trap is issued when the module detects an error while booting
from bank 0 or bank 1. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.7 |
trapdrrAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.8 |
trapdrrHardwareErrAlarmThis trap is issued when hardware is abnormal. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.9 |
trapdrrOpticalSignalAlarmThis trap is issued when the optical signal is beyond the preset range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.10 |
trapdrrFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.11 |
trapdrrResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.12 |
trapdrrTripPointAlarmThis trap is issued when the Input optical power is lower than the custumer set
trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.13 |
trapdrrLinkAlarmThis trap is issued when receiver is out of SYN with transmitter TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.14 |
trapdrrCalibrationDataCRCAlarmThis trap is issued when the Calibration Data CRC is incorrect TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.14.0.15 |
gx2drr4xDescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.14.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.14.1 |
gx2drr4xAnalogTableThis table contains gx2drr4x specific analog parameters with
nominal,limits and current values. SEQUENCE OF Gx2drr4xAnalogEntry .1.3.6.1.4.1.1166.6.1.2.14.2 |
gx2drr4xAnalogEntryThis list contains the analog parameters and descriptions. Gx2drr4xAnalogEntry .1.3.6.1.4.1.1166.6.1.2.14.2.1 |
gx2drr4xAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.2.1.1 |
drr4xlabelRFAAttenuationThe value of this object provides the label of the
RF Channel A Attenuation Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.2 |
drr4xuomRFAAttenuationThe value of this object provides the Unit of Measure of the
RF Channel A Attenuation Analog parameter. The unit is in dBro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.3 |
drr4xmajorHighRFAAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.4 |
drr4xmajorLowRFAAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.5 |
drr4xminorHighRFAAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.6 |
drr4xminorLowRFAAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.7 |
drr4xcurrentValueRFAAttenuationThe value of this object provides the Current value
of the RF Channel A Attenuation Analog parameter.rw Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.8 |
drr4xstateFlagRFAAttenuationThe value of this object provides the state
of the RF Channel A Attenuation Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.9 |
drr4xminValueRFAAttenuationThe value of this object provides the minimum value
the RF Channel A Attenuation Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.10 |
drr4xmaxValueRFAAttenuationThe value of this object provides the maximum value
the RF Channel A Attenuation Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.11 |
drr4xalarmStateRFAAttenuationThe value of this object provides the curent alarm state of
the RF Channel A Attenuation Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.12 |
drr4xlabelRFBAttenuationThe value of this object provides the label of the
RF Channel B Attenuation Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.13 |
drr4xuomRFBAttenuationThe value of this object provides the Unit of Measure of the
RF Channel B Attenuation Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.14 |
drr4xmajorHighRFBAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.15 |
drr4xmajorLowRFBAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.16 |
drr4xminorHighRFBAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.17 |
drr4xminorLowRFBAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF. It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.18 |
drr4xcurrentValueRFBAttenuationThe value of this object provides the Current value
of the RF Channel B Attenuation Analog parameter. The unit is dBrw Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.19 |
drr4xstateFlagRFBAttenuationThe value of this object provides the state
of the RF Channel B Attenuation Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.20 |
drr4xminValueRFBAttenuationThe value of this object provides the minimum value
the RF Channel B Attenuation Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.21 |
drr4xmaxValueRFBAttenuationThe value of this object provides the maximum value
the RF Channel B Attenuation Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.22 |
drr4xalarmStateRFBAttenuationThe value of this object provides the curent alarm state of
the RF Channel B Attenuation Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.23 |
drr4xlabelRFCAttenuationThe value of this object provides the label of the
RF Channel C Attenuation Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.24 |
drr4xuomRFCAttenuationThe value of this object provides the Unit of Measure of the
RF Channel C Attenuation Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.25 |
drr4xmajorHighRFCAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.26 |
drr4xmajorLowRFCAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.27 |
drr4xminorHighRFCAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.28 |
drr4xminorLowRFCAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF. It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.29 |
drr4xcurrentValueRFCAttenuationThe value of this object provides the Current value
of the RF Channel C Attenuation Analog parameter. The unit is dBrw Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.30 |
drr4xstateFlagRFCAttenuationThe value of this object provides the state
of the RF Channel C Attenuation Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.31 |
drr4xminValueRFCAttenuationThe value of this object provides the minimum value
the RF Channel C Attenuation Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.32 |
drr4xmaxValueRFCAttenuationThe value of this object provides the maximum value
the RF Channel C Attenuation Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.33 |
drr4xalarmStateRFCAttenuationThe value of this object provides the curent alarm state of
the RF Channel C Attenuation Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.34 |
drr4xlabelRFDAttenuationThe value of this object provides the label of the
RF Channel D Attenuation Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.35 |
drr4xuomRFDAttenuationThe value of this object provides the Unit of Measure of the
RF Channel D Attenuation Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.36 |
drr4xmajorHighRFDAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.37 |
drr4xmajorLowRFDAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.38 |
drr4xminorHighRFDAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.39 |
drr4xminorLowRFDAttenuationThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF. It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.40 |
drr4xcurrentValueRFDAttenuationThe value of this object provides the Current value
of the RF Channel D Attenuation Analog parameter. The unit is dBrw Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.41 |
drr4xstateFlagRFDAttenuationThe value of this object provides the state
of the RF Channel D Attenuation Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.42 |
drr4xminValueRFDAttenuationThe value of this object provides the minimum value
the RF Channel B Attenuation Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.43 |
drr4xmaxValueRFDAttenuationThe value of this object provides the maximum value
the RF Channel D Attenuation Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.44 |
drr4xalarmStateRFDAttenuationThe value of this object provides the curent alarm state of
the RF Channel D Attenuation Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.45 |
drr4xlabelTrippointLevelThe value of this object provides the label of the
trip point level Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.46 |
drr4xuomTrippointLevelThe value of this object provides the Unit of Measure of the
trip point level Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.47 |
drr4xmajorHighTrippointLevelThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.48 |
drr4xmajorLowTrippointLevelThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.49 |
drr4xminorHighTrippointLevelThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.50 |
drr4xminorLowTrippointLevelThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.51 |
drr4xcurrentValueTrippointLevelThe value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred
optical input level.
This parameter combined with trippoint mode decides the trippoint alarm and RF channel output impedance.
when optical power level is lower than trip point level(Set by this parameter)
1) When trip point mode is ALARM_SWITCH, trip point alarm will be generated and RF output
impedance will be changed to high impedance.
2) When trippoint mode is ALARM_ONLY, trippoint alarm will be generated but RF output inpedance
remains to be low impedance.
This trip point level value is a floating point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.52 |
drr4xstateFlagTrippointLevelThe value of this object provides the state
of the trip point level Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.53 |
drr4xminValueTrippointLevelThe value of this object provides the minimum value
the trip point level Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.54 |
drr4xmaxValueTrippointLevelThe value of this object provides the maximum value
the trip point level Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.55 |
drr4xalarmStateTrippointLevelThe value of this object provides the curent alarm state of
the trip point level Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.56 |
drr4xlabelOptCurrentThe value of this object provides the label of the
Optical Power Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.57 |
drr4xuomOptCurrentThe value of this object provides the Unit of Measure of the
Optical Power Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.58 |
drr4xmajorHighOptCurrentThe value of this object provides the Major High alarm value
of the Optical Power Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.59 |
drr4xmajorLowOptCurrentThe value of this object provides the Major Low alarm value
of the Optical Power Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.60 |
drr4xminorHighOptCurrentThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.61 |
drr4xminorLowOptCurrentThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.62 |
drr4xcurrentValueOptCurrentThe value of this object provides the Current value
of the Optical Power Current Analog parameter.
The input optical power in lower than min value,
drr4xcurrentValueOptCurrent will report -99dBm
The input optical power in higher than this value,
drr4xcurrentValueOptCurrent will report 99dBmro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.63 |
drr4xstateFlagOptCurrentThe value of this object provides the state
of the Optical Power Current Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.64 |
drr4xminValueOptCurrentThis is recommended min range for display gaugero Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.65 |
drr4xmaxValueOptCurrentThis is recommended max range for display gaugero Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.66 |
drr4xalarmStateOptCurrentThe value of this object provides the curent alarm state of
the Optical Power Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.67 |
drr4xlabel12VCurrentThe value of this object provides the label of the
12v power supply Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.68 |
drr4xuom12VCurrentThe value of this object provides the Unit of Measure of the
12v power supply Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.69 |
drr4xmajorHigh12VCurrentThe value of this object provides the Major High alarm value
of the 12v power supply Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.70 |
drr4xmajorLow12VCurrentThe value of this object provides the Major Low alarm value
of the 12v power supply Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.71 |
drr4xminorHigh12VCurrentThe value of this object provides the Minor High alarm value
of the 12v power supply Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.72 |
drr4xminorLow12VCurrentThe value of this object provides the Minor Low alarm value
of the 12v power supply Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.73 |
drr4xcurrentValue12VCurrentThe value of this object provides the Current value
of the 12v power supply Current parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.74 |
drr4xstateFlag12VCurrentThe value of this object provides the state
of the 12v power supply Current Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.75 |
drr4xminValue12VCurrentThe value of this object provides the minimum value
the 12v power supply Current Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.76 |
drr4xmaxValue12VCurrentThe value of this object provides the maximum value
the 12v power supply Current Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.77 |
drr4xalarmState12VCurrentThe value of this object provides the curent alarm state of
the 12v power supply Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.78 |
drr4xlabelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.79 |
drr4xuomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.80 |
drr4xmajorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.81 |
drr4xmajorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.82 |
drr4xminorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.83 |
drr4xminorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.84 |
drr4xcurrentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.85 |
drr4xstateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.86 |
drr4xminValueModTempThe value of this object provides the minimum value
the Module Temperature Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.87 |
drr4xmaxValueModTempThe value of this object provides the maximum value
the Module Temperature Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.88 |
drr4xalarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.89 |
drr4xlabelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.90 |
drr4xuomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.2.1.91 |
drr4xmajorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.92 |
drr4xmajorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.93 |
drr4xminorHighFanCurrentThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.94 |
drr4xminorLowFanCurrentThis object is not used by this module and always returns invalid float value
of 0xFFFFFFFF . It is kept here for persistence.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.95 |
drr4xcurrentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.96 |
drr4xstateFlagFanCurrentThe value of this object provides the state
of the Module Temperature Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.97 |
drr4xminValueFanCurrentThe value of this object provides the minimum value
the Fan Current Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.98 |
drr4xmaxValueFanCurrentThe value of this object provides the maximum value
the Fan Current Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.14.2.1.99 |
drr4xalarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.2.1.100 |
gx2drr4xDigitalTableThis table contains gx2drr4x specific digital parameters with
nominal and current values. SEQUENCE OF Gx2drr4xDigitalEntry .1.3.6.1.4.1.1166.6.1.2.14.3 |
gx2drr4xDigitalEntryThis list contains individual digital parameters and descriptions. Gx2drr4xDigitalEntry .1.3.6.1.4.1.1166.6.1.2.14.3.2 |
gx2drr4xDigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.3.2.1 |
drr4xlabelTrippointModeThe value of this object provides the label of the
Trip point mode Digital parameter. The trip point mode defines the RF switch
action based on the optical power input to the DRRro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.3.2.2 |
drr4xenumTrippointModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.3.2.3 |
drr4xvalueTrippointModeThe value of this object is the current value of trip point mode.
There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch.
If module input optical power is higher than the preset trippoint value,
no operational difference for these three modes.
If module input optical power is less than the preset trippoint value,
1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance
will stay normal as low.
2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power
lower than the preset trippoint level but RF output impedance will stay normal as low.
3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance
will switch to abnormlrw Enumeration .1.3.6.1.4.1.1166.6.1.2.14.3.2.4 |
drr4xstateflagTrippointModeThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.3.2.5 |
drr4xlabelFactoryDefaultResetThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.3.2.6 |
drr4xenumFactoryDefaultResetThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.3.2.7 |
drr4xvalueFactoryDefaultResetThe read of this value will return a invalid value.
The read will not reflect the actual setting value for this parameterrw Enumeration .1.3.6.1.4.1.1166.6.1.2.14.3.2.8 |
drr4xstateflagFactoryDefaultResetThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.3.2.9 |
gx2drr4xStatusTableThis table contains gx2drr4x specific status parameters with
nominal and current values. SEQUENCE OF Gx2drr4xStatusEntry .1.3.6.1.4.1.1166.6.1.2.14.4 |
gx2drr4xStatusEntryThis list contains Status parameters and descriptions. Gx2drr4xStatusEntry .1.3.6.1.4.1.1166.6.1.2.14.4.3 |
gx2drr4xStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.4.3.1 |
drr4xlabelBootThe value of this object provides the label of the
Boot Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.4.3.2 |
drr4xvalueBootThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.3 |
drr4xstateflagBootThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.4 |
drr4xlabelFlashThe value of this object provides the label of the
Flash Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.4.3.5 |
drr4xvalueFlashThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.6 |
drr4xstateflagFlashThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.7 |
drr4xlabelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.4.3.8 |
drr4xvalueFactoryDataCRCThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.9 |
drr4xstateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.10 |
drr4xlabelAlarmDataCrcThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.4.3.11 |
drr4xvalueAlarmDataCrcThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.12 |
drr4xstateflagAlarmDataCrcThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.13 |
drr4xlabelCalibrationDataCrcThe value of this object provides the label of the
Calibration Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.4.3.14 |
drr4xvalueCalibrationDataCrcThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.15 |
drr4xstateflagCalibrationDataCrcThe value of this object provides the state
of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.16 |
drr4xlabelHardwareStatusThe value of this object provides the label of the
Module Hardware Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.4.3.17 |
drr4xvalueHardwareStatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.18 |
drr4xstateflagHardwareStatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.19 |
drr4xlabelOpticTripPointStatusThe value of this object provides the label of the
Optical Trip Point Status parameter.It indicates whether
the optical power is above(0) or below(1) trip point valuero DisplayString .1.3.6.1.4.1.1166.6.1.2.14.4.3.20 |
drr4xvalueOpticTripPointStatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.21 |
drr4xstateflagOpticTripPointStatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.22 |
drr4xlabelLinkStatusThe value of this object provides the label of the
Link Activity Status parameter. It represents receiver
out of SYN with transmitter or Demux can not detect
the optical signal.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.4.3.23 |
drr4xvalueLinkStatusThe value of this object provides the current state of
the parameter (1-Ok, 2-Undetermined
3-Warning, 4-Minor, 5-Major, 6-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.24 |
drr4xstateflagLinkStatusThe value of this object provides the state
of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.4.3.25 |
gx2drr4xFactoryTableThis table contains gx2drr4x specific factory setting parameters with
nominal and current values. SEQUENCE OF Gx2drr4xFactoryEntry .1.3.6.1.4.1.1166.6.1.2.14.5 |
gx2drr4xFactoryEntryThis list contains Factory setting parameters and descriptions. Gx2drr4xFactoryEntry .1.3.6.1.4.1.1166.6.1.2.14.5.4 |
gx2drr4xFactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.5.4.1 |
drr4xbootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.5.4.2 |
drr4xbootStatusByteThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.5.4.3 |
drr4xbank1CRCThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.5.4.4 |
drr4xbank2CRCThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.5.4.5 |
drr4xprgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.5.4.6 |
drr4xfactoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.5.4.7 |
drr4xcalculateCRCThis object indicates which of the Emnums will have the
CRC calculated (1-factory, 2-alarm, 3-calibration).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.14.5.4.8 |
drr4xhourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.5.4.9 |
drr4xflashPrgCntAThis object provides the number of times Bank 0 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.5.4.10 |
drr4xflashPrgCntBThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.14.5.4.11 |
drr4xflashBankARevThis object provides the revision of flash bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.5.4.12 |
drr4xflashBankBRevThis object provides the revision of flash bank 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.5.4.13 |
drr4xSubAgentRevThis object provides the subagent revision of receiver module.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.14.5.4.14 |