Home/Catalog/OMNI-gx2drr3x-MIB

OMNI-gx2drr3x-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for OMNI-gx2drr3x-MIB.

161
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

161 total
Object Name
trapdrrConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.1
trapdrrConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.2
trapdrr12VCurrentAlarmThis trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.3
trapdrrModuleTempAlarmThis trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.4
trapdrrFanCurrentAlarmThis trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.5
trapdrrFlashAlarmThis trap is issued when the detects an error during Flash memory operations.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.6
trapdrrBankBootAlarmThis trap is issued when the detects an error while booting from bank 0 or bank 1.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.7
trapdrrAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.8
trapdrrHardwareErrAlarmThis trap is issued when hardware is abnormal.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.9
trapdrrOpticalSignalAlarmThis trap is issued when the optical signal is beyond the reason range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.10
trapdrrFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.11
trapdrrResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.12
trapdrrTripPointAlarmThis trap is issued when the Input optical power is lower than the custumer set trip point.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.13
trapdrrLinkAlarmThis trap is issued when receiver is out of SYN with transmitter
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.13.0.14
gx2drr3xDescriptor
OBJECT IDENTIFIER
.1.3.6.1.4.1.1166.6.1.2.13.1
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1166.6.1.2.13.1
gx2drr3xAnalogTableThis table contains gx2drr3x specific analog parameters with nominal,limits and current values.
SEQUENCE OF Gx2drr3xAnalogEntry
.1.3.6.1.4.1.1166.6.1.2.13.2
gx2drr3xAnalogEntryThis list contains the analog parameters and descriptions.
Gx2drr3xAnalogEntry
.1.3.6.1.4.1.1166.6.1.2.13.2.1
gx2drr3xAnalogTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.2.1.1
drrlabelRFAAttenuationThe value of this object provides the label of the RF Channel A Attenuation Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.2
drruomRFAAttenuationThe value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.3
drrmajorHighRFAAttenuationThe value of this object provides the Major High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.4
drrmajorLowRFAAttenuationThe value of this object provides the Major Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.5
drrminorHighRFAAttenuationThe value of this object provides the Minor High alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.6
drrminorLowRFAAttenuationThe value of this object provides the Minor Low alarm value of the RF Channel A Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.7
drrcurrentValueRFAAttenuationThe value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.rw
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.8
drrstateFlagRFAAttenuationThe value of this object provides the state of the RF Channel A Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.9
drrminValueRFAAttenuationThe value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.10
drrmaxValueRFAAttenuationThe value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.11
drralarmStateRFAAttenuationThe value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.12
drrlabelRFBAttenuationThe value of this object provides the label of the RF Channel B Attenuation Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.13
drruomRFBAttenuationThe value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.14
drrmajorHighRFBAttenuationThe value of this object provides the Major High alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.15
drrmajorLowRFBAttenuationThe value of this object provides the Major Low alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.16
drrminorHighRFBAttenuationThe value of this object provides the Minor High alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.17
drrminorLowRFBAttenuationThe value of this object provides the Minor Low alarm value of the RF Channel B Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.18
drrcurrentValueRFBAttenuationThe value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.rw
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.19
drrstateFlagRFBAttenuationThe value of this object provides the state of the RF Channel B Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.20
drrminValueRFBAttenuationThe value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.21
drrmaxValueRFBAttenuationThe value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.22
drralarmStateRFBAttenuationThe value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.23
drrlabelRFCAttenuationThe value of this object provides the label of the RF Channel C Attenuation Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.24
drruomRFCAttenuationThe value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.25
drrmajorHighRFCAttenuationThe value of this object provides the Major High alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.26
drrmajorLowRFCAttenuationThe value of this object provides the Major Low alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.27
drrminorHighRFCAttenuationThe value of this object provides the Minor High alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.28
drrminorLowRFCAttenuationThe value of this object provides the Minor Low alarm value of the RF Channel C Attenuation Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.29
drrcurrentValueRFCAttenuationThe value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.rw
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.30
drrstateFlagRFCAttenuationThe value of this object provides the state of the RF Channel C Attenuation Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.31
drrminValueRFCAttenuationThe value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.32
drrmaxValueRFCAttenuationThe value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.33
drralarmStateRFCAttenuationThe value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.34
drrlabelTrippointLevelThe value of this object provides the label of the trip point level Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.35
drruomTrippointLevelThe value of this object provides the Unit of Measure of the trip point level Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.36
drrmajorHighTrippointLevelThe value of this object provides the Major High alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.37
drrmajorLowTrippointLevelThe value of this object provides the Major Low alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.38
drrminorHighTrippointLevelThe value of this object provides the Minor High alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.39
drrminorLowTrippointLevelThe value of this object provides the Minor Low alarm value of the trip point level Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.40
drrcurrentValueTrippointLevelThe value of this object provides the Current value of the trippoint level Analog parameter. The trip point level set the custumer preferred optical input level. This parameter combined with trippoint mode(inside digital table) decides the trippoint alarm and RF channel output impedance. when optical power level is lower than trip point level(Set by this parameter) 1) When trip point mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will be changed to high impedance. 2) When trippoint mode is ALARM_ONLY, trippoint alarm will be generated but RF output inpedance remains to be low impedance. This trip point level value is a floating point number that is represented as an IEEE 32 bit number.rw
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.41
drrstateFlagTrippointLevelThe value of this object provides the state of the trip point level Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.42
drrminValueTrippointLevelThe value of this object provides the minimum value the trip point level Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.43
drrmaxValueTrippointLevelThe value of this object provides the maximum value the trip point level Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.44
drralarmStateTrippointLevelThe value of this object provides the curent alarm state of the trip point level Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.45
drrlabelOptCurrentThe value of this object provides the label of the Optical Power Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.46
drruomOptCurrentThe value of this object provides the Unit of Measure of the Optical Power Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.47
drrmajorHighOptCurrentThe value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.48
drrmajorLowOptCurrentThe value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.49
drrminorHighOptCurrentThe value of this object provides the Minor High alarm value of the Optical Power Current Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.50
drrminorLowOptCurrentThe value of this object provides the Minor Low alarm value of the Optical Power Current Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.51
drrcurrentValueOptCurrentThe value of this object provides the Current value of the Optical Power Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.52
drrstateFlagOptCurrentThe value of this object provides the state of the Optical Power Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.53
drrminValueOptCurrentThe value of this object provides the minimum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. The input optical power in lower than this value, drrcurrentValueOptCurrent will report -99dBmro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.54
drrmaxValueOptCurrentThe value of this object provides the maximum value the Optical Power Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. The input optical power in higher than this value, drrcurrentValueOptCurrent will report 99dBmro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.55
drralarmStateOptCurrentThe value of this object provides the curent alarm state of the Optical Power Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.56
drrlabel12VCurrentThe value of this object provides the label of the 12v power supply Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.57
drruom12VCurrentThe value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.58
drrmajorHigh12VCurrentThe value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.59
drrmajorLow12VCurrentThe value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.60
drrminorHigh12VCurrentThe value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.61
drrminorLow12VCurrentThe value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.62
drrcurrentValue12VCurrentThe value of this object provides the Current value of the 12v power supply Current parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.63
drrstateFlag12VCurrentThe value of this object provides the state of the 12v power supply Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.64
drrminValue12VCurrentThe value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.65
drrmaxValue12VCurrentThe value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.66
drralarmState12VCurrentThe value of this object provides the curent alarm state of the 12v power supply Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.67
drrlabelModTempThe value of this object provides the label of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.68
drruomModTempThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.69
drrmajorHighModTempThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.70
drrmajorLowModTempThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.71
drrminorHighModTempThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.72
drrminorLowModTempThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.73
drrcurrentValueModTempThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.74
drrstateFlagModTempThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.75
drrminValueModTempThe value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.76
drrmaxValueModTempThe value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.77
drralarmStateModTempThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.78
drrlabelFanCurrentThe value of this object provides the label of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.79
drruomFanCurrentThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.2.1.80
drrmajorHighFanCurrentThe value of this object provides the Major High alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.81
drrmajorLowFanCurrentThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.82
drrminorHighFanCurrentThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.83
drrminorLowFanCurrentThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This parameter has not been used by the module and set as the invalid float value (0xFFFFFFFF)ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.84
drrcurrentValueFanCurrentThe value of this object provides the Current value of the Fan Current Analog parameter.This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.85
drrstateFlagFanCurrentThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.86
drrminValueFanCurrentThe value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.87
drrmaxValueFanCurrentThe value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.13.2.1.88
drralarmStateFanCurrentThe value of this object provides the curent alarm state of the Fan Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.2.1.89
gx2drr3xDigitalTableThis table contains gx2drr3x specific digital parameters with nominal and current values.
SEQUENCE OF Gx2drr3xDigitalEntry
.1.3.6.1.4.1.1166.6.1.2.13.3
gx2drr3xDigitalEntryThis list contains digital parameters and descriptions.
Gx2drr3xDigitalEntry
.1.3.6.1.4.1.1166.6.1.2.13.3.2
gx2drr3xDigitalTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.3.2.1
drrlabelTrippointModeThe value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR3Xro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.3.2.2
drrenumTrippointModeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.3.2.3
drrvalueTrippointModeThe value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml as high impedancerw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.3.2.4
drrstateflagTrippointModeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.3.2.5
drrlabelFrontPanelTestThe value of this object provides the label of the Front panel test point Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.3.2.6
drrenumFrontPanelTestThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.3.2.7
drrvalueFrontPanelTestThe value of this object is the current value of Front panel RF test point Channel numberrw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.3.2.8
drrstateflagFrontPanelTestThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.3.2.9
drrlabelFactoryDefaultResetThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.3.2.10
drrenumFactoryDefaultResetThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.3.2.11
drrvalueFactoryDefaultResetThe read of this value will return a invalid value. The read will not reflect the actual setting value for this parameterrw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.3.2.12
drrstateflagFactoryDefaultResetThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.3.2.13
gx2drr3xStatusTableThis table contains gx2drr3x specific status parameters with nominal and current values.
SEQUENCE OF Gx2drr3xStatusEntry
.1.3.6.1.4.1.1166.6.1.2.13.4
gx2drr3xStatusEntryThis list contains Status parameters and descriptions.
Gx2drr3xStatusEntry
.1.3.6.1.4.1.1166.6.1.2.13.4.3
gx2drr3xStatusTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.4.3.1
drrlabelBootThe value of this object provides the label of the Boot Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.4.3.2
drrvalueBootThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.3
drrstateflagBootThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.4
drrlabelFlashThe value of this object provides the label of the Flash Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.4.3.5
drrvalueFlashThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.6
drrstateflagFlashThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.7
drrlabelFactoryDataCRCThe value of this object provides the label of the Factory Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.4.3.8
drrvalueFactoryDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.9
drrstateflagFactoryDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.10
drrlabelAlarmDataCrcThe value of this object provides the label of the Alarm Data Crc parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.4.3.11
drrvalueAlarmDataCrcThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.12
drrstateflagAlarmDataCrcThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.13
drrlabelHardwareStatusThe value of this object provides the label of the Module Hardware Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.4.3.14
drrvalueHardwareStatusThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.15
drrstateflagHardwareStatusThe value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.16
drrlabelOpticTripPointStatusThe value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point valuero
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.4.3.17
drrvalueOpticTripPointStatusThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.18
drrstateflagOpticTripPointStatusThe value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.19
drrlabelLinkStatusThe value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.4.3.20
drrvalueLinkStatusThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.21
drrstateflagLinkStatusThe value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.4.3.22
gx2drr3xFactoryTableThis table contains gx2drr3x specific factory setting parameters with nominal and current values.
SEQUENCE OF Gx2drr3xFactoryEntry
.1.3.6.1.4.1.1166.6.1.2.13.5
gx2drr3xFactoryEntryThis list contains Factory setting parameters and descriptions.
Gx2drr3xFactoryEntry
.1.3.6.1.4.1.1166.6.1.2.13.5.4
gx2drr3xFactoryTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.5.4.1
drrbootControlByteThe value of this object indicates which bank the firmware is currently being boot from.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.5.4.2
drrbootStatusByteThis object indicates the status of the last bootro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.5.4.3
drrbank1CRCThis object provides the CRC code of bank 0.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.5.4.4
drrbank2CRCThis object provides the CRC code of bank 1.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.5.4.5
drrprgEEPROMByteThis object indicates if the EEPROM has been programmedro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.5.4.6
drrfactoryCRCThis object provides the CRC code for the Factory data.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.5.4.7
drrcalculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.13.5.4.8
drrhourMeterThis object provides the hour meter reading of the module.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.5.4.9
drrflashPrgCntAThis object provides the number of times Bank 0 flash has been programmed.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.5.4.10
drrflashPrgCntBThis object provides the number of times Bank 1 flash has been programmed.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.13.5.4.11
drrflashBankARevThis object provides the revision of flash bank 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.5.4.12
drrflashBankBRevThis object provides the revision of flash bank 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.13.5.4.13
OMNI-gx2drr3x-MIB - SNMP MIB Reference | MIBs Explorer