Home/Catalog/OMNI-gx2RX200-MIB

OMNI-gx2RX200-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

139
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

139 total
Object Name
trapRX200ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.1
trapRX200ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.2
trapRX200OpticalPowerAlarmThis trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.3
trapRX200ModuleTemperatureAlarmThis trap is issued when the RX200 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.4
trapRX200FanCurrentAlarmThis trap is issued when the RX200 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.5
trapRX200Plus12CurrentAlarmThis trap is issued when the RX200 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.6
trapRX200Boot0AlarmThis trap is issued when the RX200 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.7
trapRX200Boot1AlarmThis trap is issued when the RX200 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.8
trapRX200FlashAlarmThis trap is issued when the RX200 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.9
trapRX200AlarmDataCRCAlarmThis trap is issued when the RX200 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.10
trapRX200FactoryDataCRCAlarmThis trap is issued when the RX200 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.11
trapRX200CalDataCRCAlarmThis trap is issued when the RX200 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.12
trapRX200DefaultAlarmThis trap is issued when the RX200 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.13
trapRX200ModeAlarmThis trap is issued when the RX200 Modules mode is changed from normal to off or off to normal. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.14
trapRX200OutputSwitchedAlarmThis trap is issued when the RX200 Module's output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.15
trapRX200SideStatusAlarmThis trap is issued when one of the RX200 Module's outputs are turned on or off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.6.0.16
gx2Rx200Descriptor
OBJECT IDENTIFIER
.1.3.6.1.4.1.1166.6.1.2.6.1
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1166.6.1.2.6.1
gx2Rx200AnalogTableThis table contains gx2Rx200 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx200AnalogEntry
.1.3.6.1.4.1.1166.6.1.2.6.2
gx2Rx200AnalogEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx200AnalogEntry
.1.3.6.1.4.1.1166.6.1.2.6.2.1
rxgx2Rx200AnalogTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.2.1.1
rxlabelModTempThe value of this object provides the label of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.2.1.2
rxuomModTempThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.2.1.3
rxmajorHighModTempThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.4
rxmajorLowModTempThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.5
rxminorHighModTempThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.6
rxminorLowModTempThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.7
rxcurrentValueModTempThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.8
rxstateFlagModTempThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.2.1.9
rxminValueModTempThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.10
rxmaxValueModTempThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.11
rxalarmStateModTempThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.2.1.12
rxlabelFanCurrentThe value of this object provides the label of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.2.1.13
rxuomFanCurrentThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.2.1.14
rxmajorHighFanCurrentThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.15
rxmajorLowFanCurrentThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.16
rxminorHighFanCurrentThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.17
rxminorLowFanCurrentThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.18
rxcurrentValueFanCurrentThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.19
rxstateFlagFanCurrentThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.2.1.20
rxminValueFanCurrentThe value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.21
rxmaxValueFanCurrentThe value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.22
rxalarmStateFanCurrentThe value of this object provides the curent alarm state of the Fan Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.2.1.23
rxlabel12VoltThe value of this object provides the label of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.2.1.24
rxuom12VoltThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.2.1.25
rxmajorHigh12VoltThe value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.26
rxmajorLow12VoltThe value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.27
rxminorHigh12VoltThe value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.28
rxminorLow12VoltThe value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.29
rxcurrentValue12VoltThe value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.30
rxstateFlag12VoltThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.2.1.31
rxminValue12VoltThe value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.32
rxmaxValue12VoltThe value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.33
rxalarmState12VoltThe value of this object provides the curent alarm state of the 12v Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.2.1.34
rxlabelOptPowerThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.2.1.35
rxuomOptPowerThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.2.1.36
rxmajorHighOptPowerThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.37
rxmajorLowOptPowerThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.38
rxminorHighOptPowerThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.39
rxminorLowOptPowerThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.40
rxcurrentValueOptPowerThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.41
rxstateFlagOptPowerThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.2.1.42
rxminValueOptPowerThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.43
rxmaxValueOptPowerThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.6.2.1.44
rxalarmStateOptPowerThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.2.1.45
gx2Rx200DigitalTableThis table contains gx2Rx200 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx200DigitalEntry
.1.3.6.1.4.1.1166.6.1.2.6.3
gx2Rx200DigitalEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx200DigitalEntry
.1.3.6.1.4.1.1166.6.1.2.6.3.2
rxgx2Rx200DigitalTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.3.2.1
rxlabelModeThe value of this object provides the label of the RX200's Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.2
rxenumModeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.3
rxvalueModeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.3.2.4
rxstateFlagModeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.3.2.5
rxlabelWavelengthThe value of this object provides the label of the RX200's Wavelength Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.6
rxenumWavelengthThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.7
rxvalueWavelengthThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.3.2.8
rxstateFlagWavelengthThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.3.2.9
rxlabelAttnSettingThe value of this object provides the label of the RX200's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.10
rxenumAttnSettingThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.11
rxvalueAttnSettingThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.3.2.12
rxstateFlagAttnSettingThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.3.2.13
rxlabelSwModeSettingThe value of this object provides the label of the RX200's Switch Mode Setting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.14
rxenumSwModeSettingThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.15
rxvalueSwModeSettingThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.3.2.16
rxstateFlagSwModeSettingThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.3.2.17
rxlabelSwModeThresholdThe value of this object provides the label of the RX200's Switch Mode Threshold Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.18
rxenumSwModeThresholdThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.19
rxvalueSwModeThresholdThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.3.2.20
rxstateFlagSwModeThresholdThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.3.2.21
rxlabelFactoryDefaultThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.22
rxenumFactoryDefaultThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.3.2.23
rxvalueFactoryDefaultThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.3.2.24
rxstateFlagFactoryDefaultThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.3.2.25
gx2Rx200StatusTableThis table contains gx2Rx200 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx200StatusEntry
.1.3.6.1.4.1.1166.6.1.2.6.4
gx2Rx200StatusEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx200StatusEntry
.1.3.6.1.4.1.1166.6.1.2.6.4.3
rxgx2Rx200StatusTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.4.3.1
rxlabelBootThe value of this object provides the label of the Boot Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.4.3.2
rxvalueBootThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.3
rxstateflagBootThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.4
rxlabelFlashThe value of this object provides the label of the Flash Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.4.3.5
rxvalueFlashThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.6
rxstateflagFlashThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.7
rxlabelFactoryDataCRCThe value of this object provides the label of the Factory Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.4.3.8
rxvalueFactoryDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.9
rxstateflagFactoryDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.10
rxlabelAlarmDataCRCThe value of this object provides the label of the Alarm Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.4.3.11
rxvalueAlarmDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.12
rxstateflagAlarmDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.13
rxlabelCalibrationDataCRCThe value of this object provides the label of the Calibration Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.4.3.14
rxvalueCalibrationDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.15
rxstateflagCalibrationDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.16
rxlabelThermalCompCRCThe value of this object provides the label of the Calibration Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.4.3.17
rxvalueThermalCompCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.18
rxstateflagThermalCompCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.19
rxlabelHWThe value of this object provides the label of the Hardware Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.4.3.20
rxvalueHWThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.21
rxstateflagHWThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.22
rxlabelOptSigThe value of this object provides the label of the Optical Signal Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.4.3.23
rxvalueOptSigThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.24
rxstateflagOptSigThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.4.3.25
gx2Rx200FactoryTableThis table contains gx2Rx200 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx200FactoryEntry
.1.3.6.1.4.1.1166.6.1.2.6.5
gx2Rx200FactoryEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx200FactoryEntry
.1.3.6.1.4.1.1166.6.1.2.6.5.4
rxgx2Rx200FactoryTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.5.4.1
rxbootControlByteThe value of this object indicates which bank the firmware is currently being boot from.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.5.4.2
rxbootStatusByteThis object indicates the status of the last bootro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.5.4.3
rxbank0CRCThis object provides the CRC code of bank 0.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.5.4.4
rxbank1CRCThis object provides the CRC code of bank 1.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.5.4.5
rxprgEEPROMByteThis object indicates if the EEPROM has been programmedro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.5.4.6
rxfactoryCRCThis object provides the CRC code for the Factory data.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.5.4.7
rxcalculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.6.5.4.8
rxhourMeterThis object provides the hour meter reading of the module.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.5.4.9
rxflashPrgCntAThis object provides the number of times the flash has been programmed on side A.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.5.4.10
rxflashPrgCntBThis object provides the number of times the flash has been programmed on side B.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.5.4.11
rxfwRev0This object provides the Revision of the firmware stores in bank 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.5.4.12
rxfwRev1This object provides the Revision of the firmware stores in bank 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.6.5.4.13
gx2Rx200HoldTimeTableThis table contains gx2Rx200 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx200HoldTimeEntry
.1.3.6.1.4.1.1166.6.1.2.6.6
gx2Rx200HoldTimeEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx200HoldTimeEntry
.1.3.6.1.4.1.1166.6.1.2.6.6.5
rxgx2Rx200HoldTimeTableIndexThe value of this object is the index of the data object.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.6.5.1
rxgx2Rx200HoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.6.5.2
rxgx2Rx200HoldTimeDataThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.rw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.6.6.5.3
OMNI-gx2RX200-MIB - SNMP MIB Reference | MIBs Explorer