OMNI-gx2RX1000-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

147
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

147 total
Object Name
trapRX1000ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.1
trapRX1000ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.2
trapRX1000OpticalPowerAlarmThis trap is issued when the input Optical Power parameter goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.3
trapRX1000ModuleTemperatureAlarmThis trap is issued when the RX1000 Module's Temperature goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.4
trapRX1000HeatSinkTemperatureAlarmThis trap is issued when the RX1000 Heat Sink Temperature goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.5
trapRX1000FanCurrentAlarmThis trap is issued when the RX1000 Module's Fan Currrent parameter goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.6
trapRX1000Plus12CurrentAlarmThis trap is issued when the RX1000 Module's positive 12 volt current parameter goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.7
trapRX1000OpticalSwitchAlarmThis trap is issued when the RX1000 Redundancy signal indicates a low input signal.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.8
trapRX1000Boot0AlarmThis trap is issued when the RX1000 Module's Bank 0 Boot sequence has detected an error.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.9
trapRX1000Boot1AlarmThis trap is issued when the RX1000 Module's Bank 1 Boot sequence has detected an error.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.10
trapRX1000FlashAlarmThis trap is issued when the RX1000 Module's boot or flash programming sequence has detected a Flash error.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.11
trapRX1000AlarmDataCRCAlarmThis trap is issued when the RX1000 Module detects an error calculating the alarm limit CRC.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.12
trapRX1000FactoryDataCRCAlarmThis trap is issued when the RX1000 Module detects an error calculating the Factory data CRC.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.13
trapRX1000CalDataCRCAlarmThis trap is issued when the RX1000 Module detects an error calculating the Calibration data CRC.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.14
trapRX1000ResetFacDefaultThis trap is issued when the RX1000 resets to factory defaults
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.15
trapRX1000FacCalSettingCRCAlarmThis trap is issued when the RX1000 Module detects factory calibration setting CRC alarm.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.9.0.16
gx2Rx1000Descriptor
OBJECT IDENTIFIER
.1.3.6.1.4.1.1166.6.1.2.9.1
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1166.6.1.2.9.1
gx2Rx1000AnalogTableThis table contains gx2Rx1000 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx1000AnalogEntry
.1.3.6.1.4.1.1166.6.1.2.9.2
gx2Rx1000AnalogEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx1000AnalogEntry
.1.3.6.1.4.1.1166.6.1.2.9.2.1
fprgx2Rx1000AnalogTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.2.1.1
fprlabelOptPowerThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.2.1.2
fpruomOptPowerThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.2.1.3
fprmajorHighOptPowerThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.4
fprmajorLowOptPowerThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.5
fprminorHighOptPowerThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.6
fprminorLowOptPowerThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.7
fprcurrentValueOptPowerThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.8
fprstateFlagOptPowerThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.2.1.9
fprminValueOptPowerThe value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.10
fprmaxValueOptPowerThe value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.11
fpralarmStateOptPowerThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.2.1.12
fprlabelModTempThe value of this object provides the label of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.2.1.13
fpruomModTempThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.2.1.14
fprmajorHighModTempThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.15
fprmajorLowModTempThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.16
fprminorHighModTempThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.17
fprminorLowModTempThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.18
fprcurrentValueModTempThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.19
fprstateFlagModTempThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.2.1.20
fprminValueModTempThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.21
fprmaxValueModTempThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.22
fpralarmStateModTempThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.2.1.23
fprlabelSinkTempThe value of this object provides the label of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.2.1.24
fpruomSinkTempThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.2.1.25
fprmajorHighSinkTempThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.26
fprmajorLowSinkTempThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.27
fprminorHighSinkTempThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.28
fprminorLowSinkTempThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.29
fprcurrentValueSinkTempThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.30
fprstateFlagSinkTempThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.2.1.31
fprminValueSinkTempThe value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.32
fprmaxValueSinkTempThe value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.33
fpralarmStateSinkTempThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.2.1.34
fprlabelFanCurrentThe value of this object provides the label of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.2.1.35
fpruomFanCurrentThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.2.1.36
fprmajorHighFanCurrentThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.37
fprmajorLowFanCurrentThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.38
fprminorHighFanCurrentThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.39
fprminorLowFanCurrentThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.40
fprcurrentValueFanCurrentThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.41
fprstateFlagFanCurrentThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.2.1.42
fprminValueFanCurrentThe value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.43
fprmaxValueFanCurrentThe value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.44
fpralarmStateFanCurrentThe value of this object provides the curent alarm state of the Fan Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.2.1.45
fprlabel12VoltThe value of this object provides the label of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.2.1.46
fpruom12VoltThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.2.1.47
fprmajorHigh12VoltThe value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.48
fprmajorLow12VoltThe value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.49
fprminorHigh12VoltThe value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.50
fprminorLow12VoltThe value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.51
fprcurrentValue12VoltThe value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.52
fprstateFlag12VoltThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.2.1.53
fprminValue12VoltThe value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.54
fprmaxValue12VoltThe value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.9.2.1.55
fpralarmState12VoltThe value of this object provides the curent alarm state of the 12v Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.2.1.56
gx2Rx1000DigitalTableThis table contains gx2Rx1000 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx1000DigitalEntry
.1.3.6.1.4.1.1166.6.1.2.9.3
gx2Rx1000DigitalEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx1000DigitalEntry
.1.3.6.1.4.1.1166.6.1.2.9.3.2
fprgx2Rx1000DigitalTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.3.2.1
fprlabelSlopeSettingThe value of this object provides the label of the RX1000's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.2
fprenumSlopeSettingThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.3
fprvalueSlopeSettingThe value of this object is the current value of the parameter. It is an integer value from 0 to 6. Each increment represents 1/2 dB of slope from 0 to 3 dB. Where 0 = 0db and 6 = 3dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.3.2.4
fprstateFlagSlopeSettingThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.3.2.5
fprlabelAttnSettingThe value of this object provides the label of the RX1000's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.6
fprenumAttnSettingThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.7
fprvalueAttnSettingThe value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/4 dB of attenuation from 0 to 10 dB. Where 0 = 0db and 40 = 10dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.3.2.8
fprstateFlagAttnSettingThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.3.2.9
fprlabelWavelengthThe value of this object provides the label of the RX1000's Wavelength Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.10
fprenumWavelengthThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value has a enumerated value of 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.11
fprvalueWavelengthThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.3.2.12
fprstateFlagWavelengthThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.3.2.13
fprlabelFactoryDefaultThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.14
fprenumFactoryDefaultThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.15
fprvalueFactoryDefaultThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.3.2.16
fprstateFlagFactoryDefaultThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.3.2.17
fprlabelSwModeThresholdThe value of this object provides the label of the RX1000's Switch Mode Threshold Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.18
fprenumSwModeThresholdThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value has a enumerated value of 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.19
fprvalueSwModeThresholdThe value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 0.5 dB increments ranging from -9 to +1 dB. The user can enter a number from 0 to 20, where 0 = -9db and 20= +1dbrw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.3.2.20
fprstateFlagSwModeThresholdThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.3.2.21
fprlabelSwModeSettingThe value of this object provides the label of the RX1000's Switch Mode Setting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.22
fprenumSwModeSettingThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.3.2.23
fprvalueSwModeSettingThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.3.2.24
fprstateFlagSwModeSettingThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.3.2.25
gx2Rx1000StatusTableThis table contains gx2Rx1000 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx1000StatusEntry
.1.3.6.1.4.1.1166.6.1.2.9.4
gx2Rx1000StatusEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx1000StatusEntry
.1.3.6.1.4.1.1166.6.1.2.9.4.3
fprgx2Rx1000StatusTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.4.3.1
fprlabelBootThe value of this object provides the label of the Boot Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.4.3.2
fprvalueBootThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.3
fprstateflagBootThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.4
fprlabelFlashThe value of this object provides the label of the Flash Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.4.3.5
fprvalueFlashThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.6
fprstateflagFlashThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.7
fprlabelFactoryDataCRCThe value of this object provides the label of the Factory Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.4.3.8
fprvalueFactoryDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.9
fprstateflagFactoryDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.10
fprlabelAlarmDataCRCThe value of this object provides the label of the Alarm Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.4.3.11
fprvalueAlarmDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.12
fprstateflagAlarmDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.13
fprlabelCalibrationDataCRCThe value of this object provides the label of the Calibration Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.4.3.14
fprvalueCalibrationDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.15
fprstateflagCalibrationDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.16
fprlabelFacCalSettingCRCThe value of this object provides the label of the Factor Cal Setting CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.4.3.17
fprvalueFacCalSettingCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.18
fprstateflagFacCalSettingCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.19
fprlabelInputSigThe value of this object provides the label of the Input Sig Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.4.3.20
fprvalueInputSigThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.21
fprstateflagInputSigThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.4.3.22
gx2Rx1000FactoryTableThis table contains gx2Rx1000 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx1000FactoryEntry
.1.3.6.1.4.1.1166.6.1.2.9.5
gx2Rx1000FactoryEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx1000FactoryEntry
.1.3.6.1.4.1.1166.6.1.2.9.5.4
fprgx2Rx1000FactoryTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.5.4.1
fprbootControlByteThe value of this object indicates which bank the firmware is currently being boot from.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.5.4.2
fprbootStatusByteThis object indicates the status of the last bootro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.5.4.3
fprbank0CRCThis object provides the CRC code of bank 0.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.5.4.4
fprbank1CRCThis object provides the CRC code of bank 1.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.5.4.5
fprprgEEPROMByteThis object indicates if the EEPROM has been programmedro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.5.4.6
fprfactoryCRCThis object provides the CRC code for the Factory data.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.5.4.7
fprcalculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.9.5.4.8
fprhourMeterThis object provides the hour meter reading of the module.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.5.4.9
fprflashPrgCntAThis object provides the number of times the flash has been programmed on side A.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.5.4.10
fprflashPrgCntBThis object provides the number of times the flash has been programmed on side B.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.5.4.11
fprfwRev0This object provides the Revision of the firmware stores in bank 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.5.4.12
fprfwRev1This object provides the Revision of the firmware stores in bank 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.9.5.4.13
gx2Rx1000HoldTimeTableThis table contains gx2Rx1000 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rx1000HoldTimeEntry
.1.3.6.1.4.1.1166.6.1.2.9.6
gx2Rx1000HoldTimeEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rx1000HoldTimeEntry
.1.3.6.1.4.1.1166.6.1.2.9.6.5
gx2Rx1000HoldTimeTableIndexThe value of this object is the index of the data object.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.6.5.1
gx2Rx1000HoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.6.5.2
gx2Rx1000HoldTimeDataThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.rw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.9.6.5.3