OMNI-gx2RSW200-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
110
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
110 total| Object Name |
|---|
trapRSW200ConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.1 |
trapRSW200ConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.2 |
trapRSW200RFInputAlarmThis trap is issued when the Switch Control signals
go out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.3 |
trapRSW200FanCurrentAlarmThis trap is issued when the Fan Current
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.4 |
trapRSW200ModuleTempAlarmThis trap is issued when the Temperature goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.5 |
trapRSW200FlashAlarmThis trap is issued when the detects an error during
Flash memory operations. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.6 |
trapRSW200BankBootAlarmThis trap is issued when the detects an error while booting
from bank 0 or bank 1. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.7 |
trapRSW200AlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.8 |
trapRSW200FactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.9 |
trapRSW200InputSwitchedAlarmThis trap is issued when the RF input switched. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.10 |
trapRSW200ResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.11 |
trapRSW200SecondaryInputActiveAlarmThis trap is issued when the scondary input becomes active. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.8.0.12 |
gx2Rsw200Descriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.8.1 |
gx2Rsw200AnalogTableThis table contains gx2Rsw200 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rsw200AnalogEntry .1.3.6.1.4.1.1166.6.1.2.8.2 |
gx2Rsw200AnalogEntryThis list contains the analog parameters and descriptions. Gx2Rsw200AnalogEntry .1.3.6.1.4.1.1166.6.1.2.8.2.1 |
gx2Rsw200AnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.2.1.1 |
rsw200labelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.2.1.2 |
rsw200uomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.2.1.3 |
rsw200majorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.4 |
rsw200majorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.5 |
rsw200minorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.6 |
rsw200minorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.7 |
rsw200currentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.8 |
rsw200stateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.2.1.9 |
rsw200minValueModTempThe value of this object provides the minimum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.10 |
rsw200maxValueModTempThe value of this object provides the maximum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.11 |
rsw200alarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.2.1.12 |
rsw200labelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.2.1.13 |
rsw200uomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.2.1.14 |
rsw200majorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.15 |
rsw200majorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.16 |
rsw200minorHighFanCurrentThe value of this object provides the Minor High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.17 |
rsw200minorLowFanCurrentThe value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.18 |
rsw200currentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.19 |
rsw200stateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.2.1.20 |
rsw200minValueFanCurrentThe value of this object provides the minimum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.21 |
rsw200maxValueFanCurrentThe value of this object provides the maximum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.8.2.1.22 |
rsw200alarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.2.1.23 |
gx2Rsw200DigitalTableThis table contains gx2Rsw200 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rsw200DigitalEntry .1.3.6.1.4.1.1166.6.1.2.8.3 |
gx2Rsw200DigitalEntryThis list contains digital parameters and descriptions. Gx2Rsw200DigitalEntry .1.3.6.1.4.1.1166.6.1.2.8.3.2 |
gx2Rsw200DigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.3.2.1 |
rsw200labelSwitchControlThe value of this object provides the label of the
Switch Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.2 |
rsw200enumSwitchControlThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.3 |
rsw200valueSwitchControlThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.4 |
rsw200stateflagSwitchControlThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.5 |
rsw200labelRevertModeThe value of this object provides the label of the
Revert Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.6 |
rsw200enumRevertModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.7 |
rsw200valueRevertModeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.8 |
rsw200stateflagRevertModeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.9 |
rsw200labelRevertTimeThe value of this object provides the label of the
Revert Time Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.10 |
rsw200enumRevertTimeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.11 |
rsw200valueRevertTimeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.12 |
rsw200stateflagRevertTimeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.13 |
rsw200labelSwitchStateThe value of this object provides the label of the
Switch State Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.14 |
rsw200enumSwitchStateThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.15 |
rsw200valueSwitchStateThe value of this object is the current value of the parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.16 |
rsw200stateflagSwitchStateThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.17 |
rsw200labelPriStatusThe value of this object provides the label of the
Primary Signal Status Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.18 |
rsw200enumPriStatusThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.19 |
rsw200valuePriStatusThe value of this object is the current value of the parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.20 |
rsw200stateflagPriStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.21 |
rsw200labelSecStatusThe value of this object provides the label of the
Secondary Signal Status Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.22 |
rsw200enumSecStatusThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.23 |
rsw200valueSecStatusThe value of this object is the current value of the parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.24 |
rsw200stateflagSecStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.25 |
rsw200labelFactoryDefaultThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.26 |
rsw200enumFactoryDefaultThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.3.2.27 |
rsw200valueFactoryDefaultThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.28 |
rsw200stateflagFactoryDefaultThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.3.2.29 |
gx2Rsw200StatusTableThis table contains gx2Rsw200 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rsw200StatusEntry .1.3.6.1.4.1.1166.6.1.2.8.4 |
gx2Rsw200StatusEntryThis list contains Status parameters and descriptions. Gx2Rsw200StatusEntry .1.3.6.1.4.1.1166.6.1.2.8.4.3 |
gx2Rsw200StatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.4.3.1 |
rsw200labelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.4.3.2 |
rsw200valueBootThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.3 |
rsw200stateflagBootThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.4 |
rsw200labelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.4.3.5 |
rsw200valueFlashThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.6 |
rsw200stateflagFlashThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.7 |
rsw200labelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.4.3.8 |
rsw200valueFactoryDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.9 |
rsw200stateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.10 |
rsw200labelAlarmDataCrcThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.4.3.11 |
rsw200valueAlarmDataCrcThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.12 |
rsw200stateflagAlarmDataCrcThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.13 |
rsw200labelRFSignalStatusThe value of this object provides the label of the
RF Signal Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.4.3.14 |
rsw200valueRFSignalStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.15 |
rsw200stateflagRFSignalStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.16 |
rsw200labelPriActiveStatusThe value of this object provides the label of the
Secondary Active Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.4.3.17 |
rsw200valuePriActiveStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.18 |
rsw200stateflagPriActiveStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.4.3.19 |
gx2Rsw200FactoryTableThis table contains gx2Rsw200 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rsw200FactoryEntry .1.3.6.1.4.1.1166.6.1.2.8.5 |
gx2Rsw200FactoryEntryThis list contains Factory parameters and descriptions. Gx2Rsw200FactoryEntry .1.3.6.1.4.1.1166.6.1.2.8.5.4 |
gx2Rsw200FactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.5.4.1 |
rsw200bootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.5.4.2 |
rsw200bootStatusByteThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.5.4.3 |
rsw200bank1CRCThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.5.4.4 |
rsw200bank2CRCThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.5.4.5 |
rsw200prgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.5.4.6 |
rsw200factoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.5.4.7 |
rsw200calculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.8.5.4.8 |
rsw200hourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.5.4.9 |
rsw200flashPrgCntAThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.5.4.10 |
rsw200flashPrgCntBThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.5.4.11 |
rsw200flashBankARevThis object provides the revision of flash bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.5.4.12 |
rsw200flashBankBRevThis object provides the revision of flash bank 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.8.5.4.13 |
gx2Rsw200bHoldTimeTableThis table contains gx2Rsw200b specific parameters with
nominal and current values. SEQUENCE OF Gx2Rsw200bHoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.8.6 |
gx2Rsw200bHoldTimeEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rsw200bHoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.8.6.5 |
rxgx2Rsw200bHoldTimeTableIndexThe value of this object is the index of the data object.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.6.5.1 |
rxgx2Rsw200bHoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.8.6.5.2 |
rxgx2Rsw200bHoldTimeDataThe value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds.rw INTEGER .1.3.6.1.4.1.1166.6.1.2.8.6.5.3 |