OMNI-gx2RSW1000B-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
168
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
168 total| Object Name |
|---|
trapRSW1000bConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.1 |
trapRSW1000bConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.2 |
trapRSW1000bRFInputAlarmThis trap is issued when the Switch Control signals
go out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.3 |
trapRSW1000bFanCurrentAlarmThis trap is issued when the Fan Current
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.4 |
trapRSW1000bModuleTempAlarmThis trap is issued when the Temperature goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.5 |
trapRSW1000bFlashAlarmThis trap is issued when the detects an error during
Flash memory operations. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.6 |
trapRSW1000bBankBootAlarmThis trap is issued when the detects an error while booting
from bank 0 or bank 1. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.7 |
trapRSW1000bAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.8 |
trapRSW1000bFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.9 |
trapRSW1000bInputSwitchedAlarmThis trap is issued when the RF input switched. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.10 |
trapRSW1000bResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.11 |
trapRSW1000bSecondaryInputActiveAlarmThis trap is issued when the scondary input becomes active. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.12 |
trapRSW1000bCalibrationDataCRCAlarmThis trap is issued when the calibration data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.18.0.13 |
gx2Rsw1000bDescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.18.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.18.1 |
gx2Rsw1000bAnalogTableThis table contains gx2Rsw1000b specific parameters with
nominal and current values. SEQUENCE OF Gx2Rsw1000bAnalogEntry .1.3.6.1.4.1.1166.6.1.2.18.2 |
gx2Rsw1000bAnalogEntryThis list contains the analog parameters and descriptions. Gx2Rsw1000bAnalogEntry .1.3.6.1.4.1.1166.6.1.2.18.2.1 |
gx2Rsw1000bAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.2.1.1 |
rsw1000blabelPriRFInputLvlThe value of this object provides the label of the
Primary RF Input Level Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.2 |
rsw1000buomPriRFInputLvlThe value of this object provides the Unit of Measure of the
Primary RF Input Level Analog parameter.
For all analog objects for this parameter type, the
Unit of Measure is dBmV.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.3 |
rsw1000bmajorHighPriRFInputLvlThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Major High alarm value
of the Primary RF Input Level Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.4 |
rsw1000bmajorLowPriRFInputLvlThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Major Low alarm value
of the Primary RF Input Level Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.5 |
rsw1000bminorHighPriRFInputLvlThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Minor High alarm value
of the Primary RF Input Level Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.6 |
rsw1000bminorLowPriRFInputLvlThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Minor Low alarm value
of the Primary RF Input Level Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.7 |
rsw1000bcurrentValuePriRFInputLvlThe value of this object provides the current value of the
Primary RF Input Level Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.8 |
rsw1000bstateFlagPriRFInputLvlThe value of this object provides the state
of the Primary RF Input Level Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.9 |
rsw1000bminValuePriRFInputLvlThe value of this object represents a gauge minimum
limit for the Primary RF Input Level Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.10 |
rsw1000bmaxValuePriRFInputLvlThe value of this object represents a gauge maximum
limit for the Primary RF Input Level Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.11 |
rsw1000balarmStatePriRFInputLvlThe value of this object provides the curent alarm state of
the Primary RF Input Level Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.12 |
rsw1000blabelSecRFInputLvlThe value of this object provides the label of the
Secondary RF Input Level Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.13 |
rsw1000buomSecRFInputLvlThe value of this object provides the Unit of Measure of the
Secondary RF Input Level Analog parameter.
For all analog objects for this parameter type, the
Unit of Measure is dBmV.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.14 |
rsw1000bmajorHighSecRFInputLvlThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Major High alarm value
of the Secondary RF Input Level Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.15 |
rsw1000bmajorLowSecRFInputLvlThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Major Low alarm value
of the Secondary RF Input Level Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.16 |
rsw1000bminorHighSecRFInputLvlThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Minor High alarm value
of the Secondary RF Input Level Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.17 |
rsw1000bminorLowSecRFInputLvlThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Minor Low alarm value
of the Secondary RF Input Level Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.18 |
rsw1000bcurrentValueSecRFInputLvlThe value of this object provides the current value of the
Secondary RF Input Level Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.19 |
rsw1000bstateFlagSecRFInputLvlThe value of this object provides the state
of the Secondary RF Input Level Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.20 |
rsw1000bminValueSecRFInputLvlThe value of this object represents a gauge minimum
limit for the Secondary RF Input Level Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.21 |
rsw1000bmaxValueSecRFInputLvlThe value of this object represents a gauge maximum
limit for the Secondary RF Input Level Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.22 |
rsw1000balarmStateSecRFInputLvlThe value of this object provides the curent alarm state of
the Secondary RF Input Level Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.23 |
rsw1000blabelPriRFThresholdThe value of this object provides the label of the
Primary RF Threshold Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.24 |
rsw1000buomPriRFThresholdThe value of this object provides the Unit of Measure of the
Primary RF Threshold Analog parameter.
For all analog objects for this parameter type, the
Unit of Measure is dBmV.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.25 |
rsw1000bmajorHighPriRFThresholdThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Major High alarm value
of the Primary RF Threshold Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.26 |
rsw1000bmajorLowPriRFThresholdThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Major Low alarm value
of the Primary RF Threshold Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.27 |
rsw1000bminorHighPriRFThresholdThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Minor High alarm value
of the Primary RF Threshold Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.28 |
rsw1000bminorLowPriRFThresholdThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Minor Low alarm value
of the Primary RF Threshold Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.29 |
rsw1000bcurrentValuePriRFThresholdThe value of this object provides the current value of the
Primary RF Threshold Analog parameter.rw Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.30 |
rsw1000bstateFlagPriRFThresholdThe value of this object provides the state
of the Primary RF Threshold Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.31 |
rsw1000bminValuePriRFThresholdThe value of this object represents a gauge minimum
limit for the Primary RF Threshold Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.32 |
rsw1000bmaxValuePriRFThresholdThe value of this object represents a gauge maximum
limit for the Primary RF Threshold Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.33 |
rsw1000balarmStatePriRFThresholdThe value of this object provides the curent alarm state of
the Primary RF Threshold Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.34 |
rsw1000blabelSecRFThresholdThe value of this object provides the label of the
Secondary RF Threshold Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.35 |
rsw1000buomSecRFThresholdThe value of this object provides the Unit of Measure of the
Secondary RF Threshold Analog parameter.
For all analog objects for this parameter type, the
Unit of Measure is dBmV.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.36 |
rsw1000bmajorHighSecRFThresholdThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Major High alarm value
of the Secondary RF Threshold Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.37 |
rsw1000bmajorLowSecRFThresholdThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Major Low alarm value
of the Secondary RF Threshold Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.38 |
rsw1000bminorHighSecRFThresholdThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Minor High alarm value
of the Secondary RF Threshold Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.39 |
rsw1000bminorLowSecRFThresholdThis object is not used by this module and always
returns invalid float value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Minor Low alarm value
of the Secondary RF Threshold Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.40 |
rsw1000bcurrentValueSecRFThresholdThe value of this object provides the current value of the
Secondary RF Threshold Analog parameter.rw Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.41 |
rsw1000bstateFlagSecRFThresholdThe value of this object provides the state
of the Secondary RF Threshold Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.42 |
rsw1000bminValueSecRFThresholdThe value of this object represents a gauge minimum
limit for the Secondary RF Threshold Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.43 |
rsw1000bmaxValueSecRFThresholdThe value of this object represents a gauge maximum
limit for the Secondary RF Threshold Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.44 |
rsw1000balarmStateSecRFThresholdThe value of this object provides the curent alarm state of
the Secondary RF Threshold Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.45 |
rsw1000blabelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.46 |
rsw1000buomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.
For all analog objects for this parameter type, the
Unit of Measure is degrees Celsius.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.47 |
rsw1000bmajorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.48 |
rsw1000bmajorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.49 |
rsw1000bminorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.50 |
rsw1000bminorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.51 |
rsw1000bcurrentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.52 |
rsw1000bstateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.53 |
rsw1000bminValueModTempThe value of this object represents a gauge minimum
limit for the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.54 |
rsw1000bmaxValueModTempThe value of this object represents a gauge maximum
limit for the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.55 |
rsw1000balarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.56 |
rsw1000blabelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.57 |
rsw1000buomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.
For all analog objects for this parameter type, the
Unit of Measure is mAro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.2.1.58 |
rsw1000bmajorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.59 |
rsw1000bmajorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.60 |
rsw1000bminorHighFanCurrentThis object is not used by this module and always
returns invalid floating point value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Minor High alarm value
of the Fan Current Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.61 |
rsw1000bminorLowFanCurrentThis object is not used by this module and always
returns invalid floating point value of 0xFFFFFFFF. This
object is kept here for persistence.
The value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter.roobsolete Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.62 |
rsw1000bcurrentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.63 |
rsw1000bstateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.64 |
rsw1000bminValueFanCurrentThe value of this object represents a gauge minimum
limit for the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.65 |
rsw1000bmaxValueFanCurrentThe value of this object represents a gauge maximum
limit for the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.18.2.1.66 |
rsw1000balarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.2.1.67 |
gx2Rsw1000bDigitalTableThis table contains gx2Rsw1000b specific parameters with
nominal and current values. SEQUENCE OF Gx2Rsw1000bDigitalEntry .1.3.6.1.4.1.1166.6.1.2.18.3 |
gx2Rsw1000bDigitalEntryThis list contains digital parameters and descriptions. Gx2Rsw1000bDigitalEntry .1.3.6.1.4.1.1166.6.1.2.18.3.2 |
gx2Rsw1000bDigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.3.2.1 |
rsw1000blabelSwitchControlThe value of this object provides the label of the
Switch Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.2 |
rsw1000benumSwitchControlThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.3 |
rsw1000bvalueSwitchControlThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.4 |
rsw1000bstateflagSwitchControlThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.5 |
rsw1000blabelSwitchModeThe value of this object provides the label of the
Revert Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.6 |
rsw1000benumSwitchModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.7 |
rsw1000bvalueSwitchModeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.8 |
rsw1000bstateflagSwitchModeThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.9 |
rsw1000blabelRevertEnableThe value of this object provides the label of the
Revert Enable Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.10 |
rsw1000benumRevertEnableThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.11 |
rsw1000bvalueRevertEnableThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.12 |
rsw1000bstateflagRevertEnableThe value of this object provides the state
of the the parameter. (1-hidden 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.13 |
rsw1000blabelRevertTimeThe value of this object provides the label of the
Revert Time Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.14 |
rsw1000benumRevertTimeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.15 |
rsw1000bvalueRevertTimeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.16 |
rsw1000bstateflagRevertTimeThe value of this object provides the state
of the the parameter. (1-hidden 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.17 |
rsw1000blabelSensorModeThe value of this object provides the label of the
SensorMode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.18 |
rsw1000benumSensorModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.19 |
rsw1000bvalueSensorModeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.20 |
rsw1000bstateflagSensorModeThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.21 |
rsw1000blabelSwitchMonitorThe value of this object provides the label of the
Switch Monitor Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.22 |
rsw1000benumSwitchMonitorThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.23 |
rsw1000bvalueSwitchMonitorThe value of this object is the current value of the parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.24 |
rsw1000bstateflagSwitchMonitorThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.25 |
rsw1000blabelPriStatusSigThe value of this object provides the label of the
Primary Control Signal Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.26 |
rsw1000benumPriStatusSigThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.27 |
rsw1000bvaluePriStatusSigThe value of this object is the current value of the parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.28 |
rsw1000bstateflagPriStatusSigThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.29 |
rsw1000blabelSecStatusSigThe value of this object provides the label of the
Secondary Control Signal Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.30 |
rsw1000benumSecStatusSigThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.31 |
rsw1000bvalueSecStatusSigThe value of this object is the current value of the parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.32 |
rsw1000bstateflagSecStatusSigThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.33 |
rsw1000blabelFactoryDefaultThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.34 |
rsw1000benumFactoryDefaultThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.3.2.35 |
rsw1000bvalueFactoryDefaultThis is a one-shot control value. A read of this value is
always the value corresponding to off(1). A write of the
value corresponding to on(2) results in effecting the factory
default reset. A write of the value corresponding to off(1)
has no effect.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.36 |
rsw1000bstateflagFactoryDefaultThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.3.2.37 |
gx2Rsw1000bStatusTableThis table contains gx2Rsw1000b specific parameters with
nominal and current values. SEQUENCE OF Gx2Rsw1000bStatusEntry .1.3.6.1.4.1.1166.6.1.2.18.4 |
gx2Rsw1000bStatusEntryThis list contains Status parameters and descriptions. Gx2Rsw1000bStatusEntry .1.3.6.1.4.1.1166.6.1.2.18.4.3 |
gx2Rsw1000bStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.4.3.1 |
rsw1000blabelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.4.3.2 |
rsw1000bvalueBootThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.3 |
rsw1000bstateflagBootThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.4 |
rsw1000blabelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.4.3.5 |
rsw1000bvalueFlashThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.6 |
rsw1000bstateflagFlashThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.7 |
rsw1000blabelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.4.3.8 |
rsw1000bvalueFactoryDataCRCThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.9 |
rsw1000bstateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.10 |
rsw1000blabelRFDataCRCThe value of this object provides the label of the
Radio Frequency Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.4.3.11 |
rsw1000bvalueRFDataCRCThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.12 |
rsw1000bstateflagRFDataCRCThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.13 |
rsw1000blabelAlarmDataCRCThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.4.3.14 |
rsw1000bvalueAlarmDataCRCThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.15 |
rsw1000bstateflagAlarmDataCRCThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.16 |
rsw1000blabelRFSignalStatusThe value of this object provides the label of the
RF Signal Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.4.3.17 |
rsw1000bvalueRFSignalStatusThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.18 |
rsw1000bstateflagRFSignalStatusThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.19 |
rsw1000blabelPriActiveStatusThe value of this object provides the label of the
Secondary Active Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.4.3.20 |
rsw1000bvaluePriActiveStatusThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.21 |
rsw1000bstateflagPriActiveStatusThe value of this object provides the state
of the the parameter. (1-hidden, 2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.4.3.22 |
gx2Rsw1000bFactoryTableThis table contains gx2Rsw1000b specific parameters with
nominal and current values. SEQUENCE OF Gx2Rsw1000bFactoryEntry .1.3.6.1.4.1.1166.6.1.2.18.5 |
gx2Rsw1000bFactoryEntryThis list contains Factory parameters and descriptions. Gx2Rsw1000bFactoryEntry .1.3.6.1.4.1.1166.6.1.2.18.5.4 |
gx2Rsw1000bFactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.5.4.1 |
rsw1000bbootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.5.4.2 |
rsw1000bbootStatusByteThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.5.4.3 |
rsw1000bbank0CRCThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.5.4.4 |
rsw1000bbank1CRCThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.5.4.5 |
rsw1000bprgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.5.4.6 |
rsw1000bfactoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.5.4.7 |
rsw1000bcalculateCRCThis oject indicates which of the Emnums will have the CRC calculated.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.18.5.4.8 |
rsw1000bhourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.5.4.9 |
rsw1000bflashPrgCnt0This object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.5.4.10 |
rsw1000bflashPrgCnt1This object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.5.4.11 |
rsw1000bflashBank0RevThis object provides the revision of flash bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.5.4.12 |
rsw1000bflashBank1RevThis object provides the revision of flash bank 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.5.4.13 |
rsw1000bSubagentRevThis object provides the revision of the subagent.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.18.5.4.14 |
gx2Rsw1000bHoldTimeTableThis table contains gx2Rsw1000b specific parameters with
nominal and current values. SEQUENCE OF Gx2Rsw1000bHoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.18.6 |
gx2Rsw1000bHoldTimeEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rsw1000bHoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.18.6.5 |
rxgx2Rsw1000bHoldTimeTableIndexThe value of this object is the index of the data object.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.6.5.1 |
rxgx2Rsw1000bHoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.18.6.5.2 |
rxgx2Rsw1000bHoldTimeDataThe value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds.rw INTEGER .1.3.6.1.4.1.1166.6.1.2.18.6.5.3 |