OMNI-gx2RFA1000-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for OMNI-gx2RFA1000-MIB.
107
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
107 total| Object Name |
|---|
trapRFA1000ConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.1 |
trapRFA1000ConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.2 |
trapRFA1000ModuleTemperatureAlarmThis trap is issued when the RFA1000 Module's Temperature goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.3 |
trapRFA1000FanCurrentAlarmThis trap is issued when the RFA1000 Module's Fan Currrent parameter
goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.4 |
trapRFA1000Plus12CurrentAlarmThis trap is issued when the RFA1000 Module's positive 12 volt current parameter
goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.5 |
trapRFA1000Boot0AlarmThis trap is issued when the RFA1000 Module's Bank 0 Boot sequence has detected an error. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.6 |
trapRFA1000Boot1AlarmThis trap is issued when the RFA1000 Module's Bank 1 Boot sequence has detected an error. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.7 |
trapRFA1000FlashAlarmThis trap is issued when the RFA1000 Module's boot or flash programming sequence has
detected a Flash error. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.8 |
trapRFA1000AlarmDataCRCAlarmThis trap is issued when the RFA1000 Module detects an error calculating the alarm limit CRC. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.9 |
trapRFA1000FactoryDataCRCAlarmThis trap is issued when the RFA1000 Module detects an error calculating the Factory data CRC. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.10 |
trapRFA1000SlopeCalDataCRCAlarmThis trap is issued when the RFA1000 Module detects an error calculating the Slope Calibration data CRC. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.11 |
trapRFA1000AttnCalDataCRCAlarmThis trap is issued when the RFA1000 Module detects an Attenuation Calibration Data CRC alarm. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.12 |
trapRFA1000ResetFacDefaultThis trap is issued when the RFA1000 resets to factory defaults TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.22.0.13 |
gx2Rfa1000Descriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.22.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.22.1 |
gx2Rfa1000AnalogTableThis table contains gx2Rfa1000 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rfa1000AnalogEntry .1.3.6.1.4.1.1166.6.1.2.22.2 |
gx2Rfa1000AnalogEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rfa1000AnalogEntry .1.3.6.1.4.1.1166.6.1.2.22.2.1 |
rfagx2Rfa1000AnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.2.1.1 |
rfalabelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.2.1.2 |
rfauomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter. The unit of measure for
this parameter is Degrees Cro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.2.1.3 |
rfamajorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.4 |
rfamajorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.5 |
rfaminorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.6 |
rfaminorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.7 |
rfacurrentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.8 |
rfastateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.2.1.9 |
rfaminValueModTempThe value of this object provides the minimum value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.10 |
rfamaxValueModTempThe value of this object provides the maximum value
of the Module Temperature Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.11 |
rfaalarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.2.1.12 |
rfalabelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.2.1.13 |
rfauomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter. The unit of measure for
this parameter is mAro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.2.1.14 |
rfamajorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.15 |
rfamajorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.16 |
rfaminorHighFanCurrentThe value of this object provides the Minor High alarm value
of the Fan Current Analog parameter. This object is not
used by this module and always returns invalid float
value of 0xFFFFFFFF . This object is kept here for persistenceroobsolete Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.17 |
rfaminorLowFanCurrentThe value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter. This object is not
used by this module and always returns invalid float
value of 0xFFFFFFFF . This object is kept here for persistenceroobsolete Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.18 |
rfacurrentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.19 |
rfastateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.2.1.20 |
rfaminValueFanCurrentThe value of this object provides the minimum value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.21 |
rfamaxValueFanCurrentThe value of this object provides the maximum value
of the Fan Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.22 |
rfaalarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.2.1.23 |
rfalabel12VoltThe value of this object provides the label of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.2.1.24 |
rfauom12VoltThe value of this object provides the Unit of Measure of the
12v Current Analog parameter. The unit of measure for
this parameter is mAro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.2.1.25 |
rfamajorHigh12VoltThe value of this object provides the Major High alarm value
of the 12 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.26 |
rfamajorLow12VoltThe value of this object provides the Major Low alarm value
of the 12 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.27 |
rfaminorHigh12VoltThe value of this object provides the Minor High alarm value
of the 12 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.28 |
rfaminorLow12VoltThe value of this object provides the Minor Low alarm value
of the 12 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.29 |
rfacurrentValue12VoltThe value of this object provides the Current value
of the 12 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.30 |
rfastateFlag12VoltThe value of this object provides the state
of the 12v Current Analog parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.2.1.31 |
rfaminValue12VoltThe value of this object provides the minimum value
of the 12 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.32 |
rfamaxValue12VoltThe value of this object provides the maximum value
of the 12 Volt Current Analog parameter.ro Float .1.3.6.1.4.1.1166.6.1.2.22.2.1.33 |
rfaalarmState12VoltThe value of this object provides the curent alarm state of
the 12v Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.2.1.34 |
gx2Rfa1000DigitalTableThis table contains gx2Rfa1000 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rfa1000DigitalEntry .1.3.6.1.4.1.1166.6.1.2.22.3 |
gx2Rfa1000DigitalEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rfa1000DigitalEntry .1.3.6.1.4.1.1166.6.1.2.22.3.2 |
rfagx2Rfa1000DigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.3.2.1 |
rfalabelSlopeSettingThe value of this object provides the label of the
RX1000's AttnSetting Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.3.2.2 |
rfaenumSlopeSettingThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.3.2.3 |
rfavalueSlopeSettingThe value of this object is the current value of the parameter. It is an integer
value from 1 to 7. Each increment represents 1/2 dB of slope from 1 to 4 dB.
Where 1 = 1db and 7 = 4dbrw Enumeration .1.3.6.1.4.1.1166.6.1.2.22.3.2.4 |
rfastateFlagSlopeSettingThe value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.3.2.5 |
rfalabelAttnSettingThe value of this object provides the label of the
RX1000's AttnSetting Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.3.2.6 |
rfaenumAttnSettingThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.3.2.7 |
rfavalueAttnSettingThe value of this object is the current value of the parameter. It is an integer
value from 1to 21 Each increment represents 1/4 dB of attenuation from 0 to 5 dB.
Where 1 = 0db and 21 = 5dbrw Enumeration .1.3.6.1.4.1.1166.6.1.2.22.3.2.8 |
rfastateFlagAttnSettingThe value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.3.2.9 |
rfalabelFactoryDefaultThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.3.2.10 |
rfaenumFactoryDefaultThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.3.2.11 |
rfavalueFactoryDefaultThe value of this object is the current value of the parameter.This parameter
will always read off(1)rw Enumeration .1.3.6.1.4.1.1166.6.1.2.22.3.2.12 |
rfastateFlagFactoryDefaultThe value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.3.2.13 |
gx2Rfa1000StatusTableThis table contains gx2Rfa1000 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rfa1000StatusEntry .1.3.6.1.4.1.1166.6.1.2.22.4 |
gx2Rfa1000StatusEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rfa1000StatusEntry .1.3.6.1.4.1.1166.6.1.2.22.4.3 |
rfagx2Rfa1000StatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.4.3.1 |
rfalabelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.4.3.2 |
rfavalueBootThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.3 |
rfastateflagBootThe value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.4 |
rfalabelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.4.3.5 |
rfavalueFlashThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.6 |
rfastateflagFlashThe value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.7 |
rfalabelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.4.3.8 |
rfavalueFactoryDataCRCThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.9 |
rfastateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.10 |
rfalabelAlarmDataCRCThe value of this object provides the label of the
Alarm Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.4.3.11 |
rfavalueAlarmDataCRCThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.12 |
rfastateflagAlarmDataCRCThe value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.13 |
rfalabelSlopeCalDataCRCThe value of this object provides the label of the
Calibration Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.4.3.14 |
rfavalueSlopeCalDataCRCThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.15 |
rfastateflagSlopeCalDataCRCThe value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.16 |
rfalabelAttnCalDataCRCThe value of this object provides the label of the
Factor Cal Setting CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.4.3.17 |
rfavalueAttnCalDataCRCThe value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.18 |
rfastateflagAttnCalDataCRCThe value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.22.4.3.19 |
gx2Rfa1000FactoryTableThis table contains gx2Rfa1000 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rfa1000FactoryEntry .1.3.6.1.4.1.1166.6.1.2.22.5 |
gx2Rfa1000FactoryEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rfa1000FactoryEntry .1.3.6.1.4.1.1166.6.1.2.22.5.4 |
rfagx2Rfa1000FactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.5.4.1 |
rfabootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.5.4.2 |
rfabootStatusByteThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.5.4.3 |
rfabank0CRCThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.5.4.4 |
rfabank1CRCThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.5.4.5 |
rfaprgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.5.4.6 |
rfafactoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.5.4.7 |
rfacalculateCRCThis object indicates which of the Emnums will have the CRC calculated.roobsolete Enumeration .1.3.6.1.4.1.1166.6.1.2.22.5.4.8 |
rfahourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.5.4.9 |
rfaflashPrgCntAThis object provides the number of times the flash has been
programmed on side A.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.5.4.10 |
rfaflashPrgCntBThis object provides the number of times the flash has been
programmed on side B.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.5.4.11 |
rfafwRev0This object provides the Revision of the firmware stores in bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.5.4.12 |
rfafwRev1This object provides the Revision of the firmware stores in bank 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.22.5.4.13 |
gx2Rfa1000HoldTimeTableThis table contains gx2Rfa1000 specific parameters with
nominal and current values. SEQUENCE OF Gx2Rfa1000HoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.22.6 |
gx2Rfa1000HoldTimeEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Rfa1000HoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.22.6.5 |
gx2Rfa1000HoldTimeTableIndexThe value of this object is the index of the data object.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.6.5.1 |
gx2Rfa1000HoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.22.6.5.2 |
gx2Rfa1000HoldTimeDataThe value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds.rw INTEGER .1.3.6.1.4.1.1166.6.1.2.22.6.5.3 |