Home/Catalog/OMNI-gx2RFA1000-MIB

OMNI-gx2RFA1000-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for OMNI-gx2RFA1000-MIB.

107
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

107 total
Object Name
trapRFA1000ConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.1
trapRFA1000ConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.2
trapRFA1000ModuleTemperatureAlarmThis trap is issued when the RFA1000 Module's Temperature goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.3
trapRFA1000FanCurrentAlarmThis trap is issued when the RFA1000 Module's Fan Currrent parameter goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.4
trapRFA1000Plus12CurrentAlarmThis trap is issued when the RFA1000 Module's positive 12 volt current parameter goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.5
trapRFA1000Boot0AlarmThis trap is issued when the RFA1000 Module's Bank 0 Boot sequence has detected an error.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.6
trapRFA1000Boot1AlarmThis trap is issued when the RFA1000 Module's Bank 1 Boot sequence has detected an error.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.7
trapRFA1000FlashAlarmThis trap is issued when the RFA1000 Module's boot or flash programming sequence has detected a Flash error.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.8
trapRFA1000AlarmDataCRCAlarmThis trap is issued when the RFA1000 Module detects an error calculating the alarm limit CRC.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.9
trapRFA1000FactoryDataCRCAlarmThis trap is issued when the RFA1000 Module detects an error calculating the Factory data CRC.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.10
trapRFA1000SlopeCalDataCRCAlarmThis trap is issued when the RFA1000 Module detects an error calculating the Slope Calibration data CRC.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.11
trapRFA1000AttnCalDataCRCAlarmThis trap is issued when the RFA1000 Module detects an Attenuation Calibration Data CRC alarm.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.12
trapRFA1000ResetFacDefaultThis trap is issued when the RFA1000 resets to factory defaults
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.22.0.13
gx2Rfa1000Descriptor
OBJECT IDENTIFIER
.1.3.6.1.4.1.1166.6.1.2.22.1
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1166.6.1.2.22.1
gx2Rfa1000AnalogTableThis table contains gx2Rfa1000 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rfa1000AnalogEntry
.1.3.6.1.4.1.1166.6.1.2.22.2
gx2Rfa1000AnalogEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rfa1000AnalogEntry
.1.3.6.1.4.1.1166.6.1.2.22.2.1
rfagx2Rfa1000AnalogTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.2.1.1
rfalabelModTempThe value of this object provides the label of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.2.1.2
rfauomModTempThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is Degrees Cro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.2.1.3
rfamajorHighModTempThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.4
rfamajorLowModTempThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.5
rfaminorHighModTempThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.6
rfaminorLowModTempThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.7
rfacurrentValueModTempThe value of this object provides the Current value of the Module Temperature Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.8
rfastateFlagModTempThe value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.2.1.9
rfaminValueModTempThe value of this object provides the minimum value of the Module Temperature Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.10
rfamaxValueModTempThe value of this object provides the maximum value of the Module Temperature Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.11
rfaalarmStateModTempThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.2.1.12
rfalabelFanCurrentThe value of this object provides the label of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.2.1.13
rfauomFanCurrentThe value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mAro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.2.1.14
rfamajorHighFanCurrentThe value of this object provides the Major High alarm value of the Fan Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.15
rfamajorLowFanCurrentThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.16
rfaminorHighFanCurrentThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistenceroobsolete
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.17
rfaminorLowFanCurrentThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistenceroobsolete
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.18
rfacurrentValueFanCurrentThe value of this object provides the Current value of the Fan Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.19
rfastateFlagFanCurrentThe value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.2.1.20
rfaminValueFanCurrentThe value of this object provides the minimum value of the Fan Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.21
rfamaxValueFanCurrentThe value of this object provides the maximum value of the Fan Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.22
rfaalarmStateFanCurrentThe value of this object provides the curent alarm state of the Fan Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.2.1.23
rfalabel12VoltThe value of this object provides the label of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.2.1.24
rfauom12VoltThe value of this object provides the Unit of Measure of the 12v Current Analog parameter. The unit of measure for this parameter is mAro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.2.1.25
rfamajorHigh12VoltThe value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.26
rfamajorLow12VoltThe value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.27
rfaminorHigh12VoltThe value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.28
rfaminorLow12VoltThe value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.29
rfacurrentValue12VoltThe value of this object provides the Current value of the 12 Volt Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.30
rfastateFlag12VoltThe value of this object provides the state of the 12v Current Analog parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.2.1.31
rfaminValue12VoltThe value of this object provides the minimum value of the 12 Volt Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.32
rfamaxValue12VoltThe value of this object provides the maximum value of the 12 Volt Current Analog parameter.ro
Float
.1.3.6.1.4.1.1166.6.1.2.22.2.1.33
rfaalarmState12VoltThe value of this object provides the curent alarm state of the 12v Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.2.1.34
gx2Rfa1000DigitalTableThis table contains gx2Rfa1000 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rfa1000DigitalEntry
.1.3.6.1.4.1.1166.6.1.2.22.3
gx2Rfa1000DigitalEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rfa1000DigitalEntry
.1.3.6.1.4.1.1166.6.1.2.22.3.2
rfagx2Rfa1000DigitalTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.3.2.1
rfalabelSlopeSettingThe value of this object provides the label of the RX1000's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.3.2.2
rfaenumSlopeSettingThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.3.2.3
rfavalueSlopeSettingThe value of this object is the current value of the parameter. It is an integer value from 1 to 7. Each increment represents 1/2 dB of slope from 1 to 4 dB. Where 1 = 1db and 7 = 4dbrw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.3.2.4
rfastateFlagSlopeSettingThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.3.2.5
rfalabelAttnSettingThe value of this object provides the label of the RX1000's AttnSetting Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.3.2.6
rfaenumAttnSettingThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.3.2.7
rfavalueAttnSettingThe value of this object is the current value of the parameter. It is an integer value from 1to 21 Each increment represents 1/4 dB of attenuation from 0 to 5 dB. Where 1 = 0db and 21 = 5dbrw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.3.2.8
rfastateFlagAttnSettingThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.3.2.9
rfalabelFactoryDefaultThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.3.2.10
rfaenumFactoryDefaultThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.3.2.11
rfavalueFactoryDefaultThe value of this object is the current value of the parameter.This parameter will always read off(1)rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.3.2.12
rfastateFlagFactoryDefaultThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.3.2.13
gx2Rfa1000StatusTableThis table contains gx2Rfa1000 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rfa1000StatusEntry
.1.3.6.1.4.1.1166.6.1.2.22.4
gx2Rfa1000StatusEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rfa1000StatusEntry
.1.3.6.1.4.1.1166.6.1.2.22.4.3
rfagx2Rfa1000StatusTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.4.3.1
rfalabelBootThe value of this object provides the label of the Boot Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.4.3.2
rfavalueBootThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.3
rfastateflagBootThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.4
rfalabelFlashThe value of this object provides the label of the Flash Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.4.3.5
rfavalueFlashThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.6
rfastateflagFlashThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.7
rfalabelFactoryDataCRCThe value of this object provides the label of the Factory Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.4.3.8
rfavalueFactoryDataCRCThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.9
rfastateflagFactoryDataCRCThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.10
rfalabelAlarmDataCRCThe value of this object provides the label of the Alarm Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.4.3.11
rfavalueAlarmDataCRCThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.12
rfastateflagAlarmDataCRCThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.13
rfalabelSlopeCalDataCRCThe value of this object provides the label of the Calibration Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.4.3.14
rfavalueSlopeCalDataCRCThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.15
rfastateflagSlopeCalDataCRCThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.16
rfalabelAttnCalDataCRCThe value of this object provides the label of the Factor Cal Setting CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.4.3.17
rfavalueAttnCalDataCRCThe value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.18
rfastateflagAttnCalDataCRCThe value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.4.3.19
gx2Rfa1000FactoryTableThis table contains gx2Rfa1000 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rfa1000FactoryEntry
.1.3.6.1.4.1.1166.6.1.2.22.5
gx2Rfa1000FactoryEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rfa1000FactoryEntry
.1.3.6.1.4.1.1166.6.1.2.22.5.4
rfagx2Rfa1000FactoryTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.5.4.1
rfabootControlByteThe value of this object indicates which bank the firmware is currently being boot from.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.5.4.2
rfabootStatusByteThis object indicates the status of the last bootro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.5.4.3
rfabank0CRCThis object provides the CRC code of bank 0.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.5.4.4
rfabank1CRCThis object provides the CRC code of bank 1.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.5.4.5
rfaprgEEPROMByteThis object indicates if the EEPROM has been programmedro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.5.4.6
rfafactoryCRCThis object provides the CRC code for the Factory data.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.5.4.7
rfacalculateCRCThis object indicates which of the Emnums will have the CRC calculated.roobsolete
Enumeration
.1.3.6.1.4.1.1166.6.1.2.22.5.4.8
rfahourMeterThis object provides the hour meter reading of the module.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.5.4.9
rfaflashPrgCntAThis object provides the number of times the flash has been programmed on side A.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.5.4.10
rfaflashPrgCntBThis object provides the number of times the flash has been programmed on side B.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.5.4.11
rfafwRev0This object provides the Revision of the firmware stores in bank 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.5.4.12
rfafwRev1This object provides the Revision of the firmware stores in bank 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.22.5.4.13
gx2Rfa1000HoldTimeTableThis table contains gx2Rfa1000 specific parameters with nominal and current values.
SEQUENCE OF Gx2Rfa1000HoldTimeEntry
.1.3.6.1.4.1.1166.6.1.2.22.6
gx2Rfa1000HoldTimeEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Rfa1000HoldTimeEntry
.1.3.6.1.4.1.1166.6.1.2.22.6.5
gx2Rfa1000HoldTimeTableIndexThe value of this object is the index of the data object.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.6.5.1
gx2Rfa1000HoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.6.5.2
gx2Rfa1000HoldTimeDataThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.rw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.22.6.5.3
OMNI-gx2RFA1000-MIB - SNMP MIB Reference | MIBs Explorer