trapPSDCConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.1 |
trapPSDCConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.2 |
trapPSDCFanCurrentThis trap is issued when a Fan Current event has occurred. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.3 |
trapPSDC12VoltThis trap is issued when the 12 Volts is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.4 |
trapPSDC5VoltThis trap is issued when the 5 Voltage is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.5 |
trapPSDC3VoltThis trap is issued when the 3.7 Voltage is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.6 |
trapPSDCAmbientTempThis trap is issued when the Ambient Temperature is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.7 |
trapPSDCMainTempThis trap is issued when the Main Temperature is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.8 |
trapPSDC12AnodeVoltThis trap is issued when the 12 Anode Voltage is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.9 |
trapPSDC5AnodeVoltThis trap is issued when the 5 Anode Voltage is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.10 |
trapPSDC3AnodeVoltThis trap is issued when the 3 Anode Voltage is in an alarm condition. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.11 |
trapPSDCEEChksmAlarmThis trap is issued when the Power Supply EEPROM Factory data CRC fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.12 |
trapPSDCFlashAlarmThis trap is issued when the embedded board flash has a problem. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.13 |
trapPSDCBootAlarmThis trap is issued when the Module Boot from either bank fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.14 |
trapPSDCAlarmReportingStatusThis trap is issued when the Alarm reporting is turned off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.15 |
trapPSbrickTypeThis trap is issued when power supply brick type is not a valid type. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.16 |
trapPSsupplyFailureThis trap is issued when power supply fail condition occurs.
(+12V , +5.1V, or _3.7V anode voltage out of spec.) TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.17 |
trapPSDCALARMChksmAlarmThis trap is issued when the Power Supply Alarm Data CRC check fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.7.0.18 |
gx2PsdcDescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.7.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.7.1 |
gx2PsdcAnalogTableThis table contains gx2Psdc specific parameters with
nominal and current values. SEQUENCE OF Gx2PsdcAnalogEntry .1.3.6.1.4.1.1166.6.1.2.7.2 |
gx2PsdcAnalogEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2PsdcAnalogEntry .1.3.6.1.4.1.1166.6.1.2.7.2.1 |
gx2PsdcAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.2.1.1 |
pslabelFanCurrentThe value of this object provides the label of the Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.2 |
psuomFanCurrentThe value of this object provides the Unit of Measure of the Fan Current Analog
parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.3 |
psmajorHighFanCurrentThe value of this object provides the Major High alarm value of the Fan Current
Analog parameter. This value is a floating point number that is represented as
an IEEE 32 Bit numberro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.4 |
psmajorLowFanCurrentThe value of this object provides the Major Low alarm value of the Fan Current
Analog parameter. This value is a floating point number that is represented as
an IEEE 32 Bit numberro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.5 |
psminorHighFanCurrentThe value of this object provides the Minor High alarm value of the Fan Current
Analog parameter. This value is a floating point number that is represented as
an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.6 |
psminorLowFanCurrentThe value of this object provides the Minor Low alarm value of the Fan Current
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.7 |
pscurrentValueFanCurrentThe value of this object provides the Current value of the Fan Current Analog
parameter. This value is a floating point number that is represented as an
IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.8 |
psstateFlagFanCurrentThe value of this object provides the state of the Fan Current Analog
parameter. (0-Hidden 1-Read-Only, 2-Updateable)ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.9 |
psminValueFanCurrentThe value of this object provides the minimum value the Fan Current Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.10 |
psmaxValueFanCurrentThe value of this object provides the maximum value the Fan Current Analog
parameter can achive. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.11 |
psalarmStateFanCurrentThe value of this object provides the curent alarm state of the Fan Current
Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.12 |
pslabel12VoltThe value of this object provides the label of the 12 Volt Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.13 |
psuom12VoltThe value of this object provides the unit of measure of the 12 Volt
Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.14 |
psmajorHigh12VoltThe value of this object provides the Major High alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.15 |
psmajorLow12VoltThe value of this object provides the Major Low alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.16 |
psminorHigh12VoltThe value of this object provides the Minor High alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.17 |
psminorLow12VoltThe value of this object provides the Minor Low alarm value of the 12 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.18 |
pscurrentValue12VoltThe value of this object provides the Current value of the 12 Volt Analog
parameter. This value is a floating point number that is represented as an
IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.19 |
psstateFlag12VoltThe value of this object provides the state of the 12 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable)ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.20 |
psminValue12VoltThe value of this object provides the minimum value the 12 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.21 |
psmaxValue12VoltThe value of this object provides the maximum value the 12 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.22 |
psalarmState12VoltThe value of this object provides the curent alarm state of the 12 Volt Analog
parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.23 |
pslabel5VoltThe value of this object provides the label of the Attenuator Setting Analog
parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.24 |
psuom5VoltThe value of this object provides the Unit of Measure of the 5 Volt Analog
parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.25 |
psmajorHigh5VoltThe value of this object provides the Major High alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.26 |
psmajorLow5VoltThe value of this object provides the Major Low alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.27 |
psminorHigh5VoltThe value of this object provides the Minor High alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.28 |
psminorLow5VoltThe value of this object provides the Minor Low alarm value of the 5 Volt
Analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.29 |
pscurrentValue5VoltThe value of this object provides the Current value of the 5 Volt Analog
parameter. This value is a floating point number that is represented as
an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.30 |
psstateFlag5VoltThe value of this object provides the state of the 5 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.31 |
psminValue5VoltThe value of this object provides the minimum value the 5 Volt Analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.32 |
psmaxValue5VoltThe value of this object provides the maximum value the 5 Volt Analog parameter
can achieve. This value is a floating point number that is represented as an
IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.33 |
psalarmState5VoltThe value of this object provides the curent alarm state of the 5 Volt
Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.34 |
pslabel3VoltThe value of this object provides the label of the
3 Anode Volt Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.35 |
psuom3VoltThe value of this object provides the Unit of Measure of the 3.7V anode voltage
analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.36 |
psmajorHigh3VoltThe value of this object provides the Major High alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.37 |
psmajorLow3VoltThe value of this object provides the Major Low alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.38 |
psminorHigh3VoltThe value of this object provides the Minor High alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.39 |
psminorLow3VoltThe value of this object provides the Minor Low alarm value of the 3.7V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.40 |
pscurrentValue3VoltThe value of this object provides the Current value of the 3.7V anode voltage
analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.41 |
psstateFlag3VoltThe value of this object provides the state of the 3 Volt Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.42 |
psminValue3VoltThe value of this object provides the minimum value that the 3.7V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.43 |
psmaxValue3VoltThe value of this object provides the maximum value that the 3.7V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.44 |
psalarmState3VoltThe value of this object provides the curent alarm state of the 3.7V anode
voltage analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.45 |
pslabelAmbientTempThe value of this object provides the label of the
Ambient Temperature Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.46 |
psuomAmbientTempThe value of this object provides the Unit of Measure of the
Ambient Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.47 |
psmajorHighAmbientTempThe value of this object provides the Major High alarm value
of the Ambient Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.48 |
psmajorLowAmbientTempThe value of this object provides the Major Low alarm value
of the Ambient Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.49 |
psminorHighAmbientTempThe value of this object provides the Minor High alarm value
of the Ambient Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.50 |
psminorLowAmbientTempThe value of this object provides the Minor Low alarm value
of the Ambient Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.51 |
pscurrentValueAmbientTempThe value of this object provides the Current value
of the Ambient Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.52 |
psstateFlagAmbientTempThe value of this object provides the state
of the Ambient Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.53 |
psminValueAmbientTempThe value of this object provides the minimum value
the Ambient Temperature Analog parameter can achive.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.54 |
psmaxValueAmbientTempThe value of this object provides the maximum value
the Ambient Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.55 |
psalarmStateAmbientTempThe value of this object provides the curent alarm state of
the Ambient Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.56 |
pslabelMainTempThe value of this object provides the label of the
Main Board Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.57 |
psuomMainTempThe value of this object provides the Unit of Measure of the
Main Board Temperature Analog parameter..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.58 |
psmajorHighMainTempThe value of this object provides the Major High alarm value of the Main Board
Temperature Analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.59 |
psmajorLowMainTempThe value of this object provides the Major Low alarm value of the Main Board
Temperature Analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.60 |
psminorHighMainTempThe value of this object provides the Minor High alarm value of the Main Board
Temperature Analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.61 |
psminorLowMainTempThe value of this object provides the Minor Low alarm value of the Main Board
Temperature Analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.62 |
pscurrentValueMainTempThe value of this object provides the Current value of the Main Board
Temperature Analog parameter. This value is a floating point number that
is represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.63 |
psstateFlagMainTempThe value of this object provides the state of the Main Board Temperature
Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.64 |
psminValueMainTempThe value of this object provides the minimum value the Main Board Temperature
Analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.65 |
psmaxValueMainTempThe value of this object provides the maximum value the Main Board Temperature
Analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.66 |
psalarmStateMainTempThe value of this object provides the curent alarm state of
the Main Board Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.67 |
pslabel12AnodeVoltThe value of this object provides the label of the
+12 Anode Voltage Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.68 |
psuom12AnodeVoltThe value of this object provides the Unit of Measure of the
+12 Anode Voltage Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.69 |
psmajorHigh12AnodeVoltThe value of this object provides the Major High alarm value of the +12V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.70 |
psmajorLow12AnodeVoltThe value of this object provides the Major Low alarm value of the +12V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.71 |
psminorHigh12AnodeVoltThe value of this object provides the Minor High alarm value of the +12V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.72 |
psminorLow12AnodeVoltThe value of this object provides the Minor Low alarm value of the +12V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.73 |
pscurrentValue12AnodeVoltThe value of this object provides the Current value of the +12V anode voltage
analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.74 |
psstateFlag12AnodeVoltThe value of this object provides the state of the +12V anode voltage
analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.75 |
psminValue12AnodeVoltThe value of this object provides the minimum value the +12V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.76 |
psmaxValue12AnodeVoltThe value of this object provides the maximum value the +12V anode voltage
analog parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.77 |
psalarmState12AnodeVoltThe value of this object provides the curent alarm state of
the +12V anode voltage analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.78 |
pslabel5AnodeVoltThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.79 |
psuom5AnodeVoltThe value of this object provides the Unit of Measure of the
5 Anode Volt Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.80 |
psmajorHigh5AnodeVoltThe value of this object provides the Major High alarm value of the 5V anode
voltage analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.81 |
psmajorLow5AnodeVoltThe value of this object provides the Major Low alarm value of the 5V anode
volt analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.82 |
psminorHigh5AnodeVoltThe value of this object provides the Minor High alarm value of the 5V anode
volt analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.83 |
psminorLow5AnodeVoltThe value of this object provides the Minor Low alarm value of the 5V anode
volt analog parameter. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.84 |
pscurrentValue5AnodeVoltThe value of this object provides the Current value of the 5V anode volt
analog parameter. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.85 |
psstateFlag5AnodeVoltThe value of this object provides the state
of the 5 Anode Volt Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.86 |
psminValue5AnodeVoltThe value of this object provides the minimum value the 5V anode volt analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.87 |
psmaxValue5AnodeVoltThe value of this object provides the maximum value the 5V anode volt analog
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.88 |
psalarmState5AnodeVoltThe value of this object provides the curent alarm state of the 5V anode
voltage analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.89 |
pslabel3AnodeVoltThe value of this object provides the label of the 3.7V anode voltage
parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.90 |
psuom3AnodeVoltThe value of this object provides the Unit of Measure of the 3.7V anode voltage
parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.2.1.91 |
psmajorHigh3AnodeVoltThe value of this object provides the Major High alarm value for the 3.7V anode
voltage parameter. This value is a floating point number that is represented as
an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.92 |
psmajorLow3AnodeVoltThe value of this object provides the Major Low alarm value for the 3.7V anode
voltage parameter. This value is a floating point number that is represented as
an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.93 |
psminorHigh3AnodeVoltThe value of this object provides the Minor High alarm value for the 3.7V anode
voltage parameter. This value is a floating point number that is represented as
an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.94 |
psminorLow3AnodeVoltThe value of this object provides the Minor Low alarm value for the 3.7V anode
voltage parameter. This value is a floating point number that is represented as
an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.95 |
pscurrentValue3AnodeVoltThe value of this object provides the Current value of the 3.7V anode voltage
parameter. This value is a floating point number that is represented as an
IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.96 |
psstateFlag3AnodeVoltThe value of this object provides the state of the 3.7V anode voltage
parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.97 |
psminValue3AnodeVoltThe value of this object provides the minimum value that 3.7V anode voltage
parameter can achieve. This value is a floating point number that is represented
as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.98 |
psmaxValue3AnodeVoltThe value of this object provides the maximum value that 3.7V anode voltage
parameter can achieve. This value is a floating point number that is
represented as an IEEE 32 Bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.7.2.1.99 |
psalarmState3AnodeVoltThe value of this object provides the curent alarm state of the 3.7V anode
voltage parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.2.1.100 |
gx2PsdcStatusTableThis table contains gx2Psdc specific parameters with
nominal and current values. SEQUENCE OF Gx2PsdcStatusEntry .1.3.6.1.4.1.1166.6.1.2.7.3 |
gx2PsdcStatusEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2PsdcStatusEntry .1.3.6.1.4.1.1166.6.1.2.7.3.2 |
gx2PsdcStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.3.2.1 |
pslabelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.3.2.2 |
psvalueBootThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.3.2.3 |
psstateflagBootThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.3.2.4 |
pslabelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.3.2.5 |
psvalueFlashThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.3.2.6 |
psstateflagFlashThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.3.2.7 |
pslabelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.3.2.8 |
psvalueFactoryDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.3.2.9 |
psstateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.3.2.10 |
pslabelPsdcDataCRCThe value of this object provides the label of the
Laser Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.3.2.11 |
psvaluePsdcDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.3.2.12 |
psstateflagPsdcDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.3.2.13 |
pslabelPsdcHwStatusThe value of this object provides the label of the
Hw Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.3.2.14 |
psvaluePsdcHwStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.3.2.15 |
psstateflagPsdcHwStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.3.2.16 |
gx2PsdcFactoryTableThis table contains gx2Psdc specific parameters with
nominal and current values. SEQUENCE OF Gx2PsdcFactoryEntry .1.3.6.1.4.1.1166.6.1.2.7.4 |
gx2PsdcFactoryEntryThis list contains Factory parameters and descriptions. Gx2PsdcFactoryEntry .1.3.6.1.4.1.1166.6.1.2.7.4.3 |
gx2PsdcFactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.4.3.1 |
psbootControlByteValueThe value of this object indicates which bank the firmware
is currently being boot from.
Boot Control Byte bit definition as follows :
bit 0 : boot bit (0=boot from bank 0, 1=boot from bank 1)
bit 1 : bank 0 status (0=bank is blank/bad, 1=bank is OK)
bit 2 : bank 1 status (0=bank is blank/bad, 1=bank is OK)
bits 3-7 : not usedro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.4.3.2 |
psbootStatusByteValueThis object indicates the status of the last boot
Boot Status Byte bit definitions as follows:
bit 0 : bank 0 status (0=bank is OK or not used, 1=bank failed boot)
bit 1 : bank 1 status (0=bank is OK or not used, 1=bank failed boot)
bit 2 : active bank (0=bank 0 active, 1=bank 1 active)
bits 3-7: not usedro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.4.3.3 |
psbank1CRCValueThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.4.3.4 |
psbank2CRCValueThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.4.3.5 |
psprgEEPROMByteValueThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.4.3.6 |
psfactoryCRCValueThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.4.3.7 |
pscalculateCRCValueThis object indicates which of the Emnums will have the CRC calculated.
Calculate CRC command defintions as follows :
0x00 : recalculate factory data CRC
0x02 : recalculate alarm data CRC
other values not definedro Enumeration .1.3.6.1.4.1.1166.6.1.2.7.4.3.8 |
pshourMeterValueThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.4.3.9 |
psflashPrgCntAValueThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.4.3.10 |
psflashPrgCntBValueThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.4.3.11 |
psflashBankARevValueThis object provides the CRC code of bank 0.
The value is best displayed in Hex formatro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.4.3.12 |
psflashBankBRevValueThis object provides the CRC code of bank 1.
The value is best displayed in Hex formatro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.4.3.13 |
gx2PsdcHoldTimeTableThis table contains gx2Psdc specific parameters with
nominal and current values. SEQUENCE OF Gx2PsdcHoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.7.5 |
gx2PsdcHoldTimeEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2PsdcHoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.7.5.4 |
rxgx2PsdcHoldTimeTableIndexThe value of this object is the index of the data object.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.5.4.1 |
rxgx2PsdcHoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.5.4.2 |
rxgx2PsdcHoldTimeDataThe value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds.rw INTEGER .1.3.6.1.4.1.1166.6.1.2.7.5.4.3 |
gx2PsdcDigitalTableThis table contains gx2Psdc specific parameters with
nominal and current values. SEQUENCE OF Gx2PsdcDigitalEntry .1.3.6.1.4.1.1166.6.1.2.7.6 |
gx2PsdcDigitalEntryThis list contains digital parameters and descriptions. Gx2PsdcDigitalEntry .1.3.6.1.4.1.1166.6.1.2.7.6.5 |
gx2PsdcDigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.7.6.5.1 |
psdclabelNVfanAlrmThe value of this object provides the label of the
RF Input Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.6.5.2 |
psdcenumNVfanAlrmThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.7.6.5.3 |
psdcvalueNVfanAlrmThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.7.6.5.4 |
psdcstateflagNVfanAlrmThe value of this object provides the state
of the RF Input Control Digital parameter. (0-Hidden