OMNI-gx2Lm870C-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for OMNI-gx2Lm870C-MIB.
172
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
172 total| Object Name |
|---|
trapLM870CConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.1 |
trapLMCConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.2 |
trapLMCFanCurrentAlarmThis trap is issued when the Laser Modules Fan Current
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.3 |
trapLMC12vAlarmThis trap is issued when the Laser Modules 12 Volt parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.4 |
trapLMCModuleTempAlarmThis trap is issued when the Laser Module Temperature goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.5 |
trapLMCRFPowerAlarmThis trap is issued when the Laser Modules RF Power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.6 |
trapLMCOPTPowerAlarmThis trap is issued when the Laser Modules Optical Power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.7 |
trapLMCLaserBiasAlarmThis trap is issued when the Laser Bias parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.8 |
trapLMCTECCurrentAlarmThis trap is issued when the Laser Modules TEC Current parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.9 |
trapLMCFlashAlarmThis trap is issued when the Laser Modules detects an error during
Flash memory operations. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.10 |
trapLMCBankBootAlarmThis trap is issued when the Laser Modules detects an error while booting
from bank 0 or bank 1. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.11 |
trapLMCAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.12 |
trapLMCModSetDataCRCAlarmThis trap is issued when the Module Settings CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.13 |
trapLMCFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.14 |
trapLMCResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.15 |
trapLMCOPCalDataCRCAlarmThis trap is issued when the Optical Calibration Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.16 |
trapLMCRFCalDataCRCAlarmThis trap is issued when the RF Calibration Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.17 |
trapLMCRFOverloadAlarmThis trap is issued when the RF Overload alarm occurs. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.18 |
trapLMCOMIoffsetAlarmThis trap is issued when an OMI Offset alarm occurs. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.10.0.19 |
gx2Lm870CDescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.10.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.10.1 |
gx2lm870CAnalogTableThis table contains gx2Lm870C specific parameters with
nominal and current values. SEQUENCE OF Gx2Lm870CAnalogEntry .1.3.6.1.4.1.1166.6.1.2.10.2 |
gx2lm870CAnalogEntryThis list contains the analog parameters and descriptions. Gx2Lm870CAnalogEntry .1.3.6.1.4.1.1166.6.1.2.10.2.1 |
gx2Lm870CAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.2.1.1 |
lm870ClabelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.2 |
lm870CuomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.3 |
lm870CmajorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.4 |
lm870CmajorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.5 |
lm870CminorHighFanCurrentThe value of this object provides the Minor High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.6 |
lm870CminorLowFanCurrentThe value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.7 |
lm870CcurrentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.8 |
lm870CstateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.9 |
lm870CminValueFanCurrentThe value of this object provides the minimum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.10 |
lm870CmaxValueFanCurrentThe value of this object provides the maximum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.11 |
lm870CalarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.12 |
lm870Clabel12VoltThe value of this object provides the label of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.13 |
lm870Cuom12VoltThe value of this object provides the Unit of Measure of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.14 |
lm870CmajorHigh12VoltThe value of this object provides the Major High alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.15 |
lm870CmajorLow12VoltThe value of this object provides the Major Low alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.16 |
lm870CminorHigh12VoltThe value of this object provides the Minor High alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.17 |
lm870CminorLow12VoltThe value of this object provides the Minor Low alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.18 |
lm870CcurrentValue12VoltThe value of this object provides the Current value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.19 |
lm870CstateFlag12VoltThe value of this object provides the state
of the 12v Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.20 |
lm870CminValue12VoltThe value of this object provides the minimum value
the 12v Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.21 |
lm870CmaxValue12VoltThe value of this object provides the maximum value
the 12v Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.22 |
lm870CalarmState12VoltThe value of this object provides the curent alarm state of
the 12v Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.23 |
lm870ClabelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.24 |
lm870CuomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.25 |
lm870CmajorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.26 |
lm870CmajorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.27 |
lm870CminorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.28 |
lm870CminorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.29 |
lm870CcurrentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.30 |
lm870CstateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.31 |
lm870CminValueModTempThe value of this object provides the minimum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.32 |
lm870CmaxValueModTempThe value of this object provides the maximum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.33 |
lm870CalarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.34 |
lm870ClabelOmiOffsetThe value of this object provides the label of the
OMI Offset Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.35 |
lm870CuomOmiOffsetThe value of this object provides the Unit of Measure of the
OMI Offset Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.36 |
lm870CmajorHighOmiOffsetThe value of this object provides the Major High alarm value
of the OMI Offset Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.37 |
lm870CmajorLowOmiOffsetThe value of this object provides the Major Low alarm value
of the OMI Offset Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.38 |
lm870CminorHighOmiOffsetThe value of this object provides the Minor High alarm value
of the OMI Offset Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.39 |
lm870CminorLowOmiOffsetThe value of this object provides the Minor Low alarm value
of the OMI Offset Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.40 |
lm870CcurrentValueOmiOffsetThe value of this object provides the Current value
of the OMI Offset Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.41 |
lm870CstateFlagOmiOffsetThe value of this object provides the state
of the OMI Offset Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.42 |
lm870CminValueOmiOffsetThe value of this object provides the minimum value
the OMI Offset Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.43 |
lm870CmaxValueOmiOffsetThe value of this object provides the maximum value
the OMI Offset Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.44 |
lm870CalarmStateOmiOffsetThe value of this object provides the curent alarm state of
the OMI Offset Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.45 |
lm870ClabelOPTPowerThe value of this object provides the label of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.46 |
lm870CuomOPTPowerThe value of this object provides the Unit of Measure of the
Optical Power Analog parameter..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.47 |
lm870CmajorHighOPTPowerThe value of this object provides the Major High alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.48 |
lm870CmajorLowOPTPowerThe value of this object provides the Major Low alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.49 |
lm870CminorHighOPTPowerThe value of this object provides the Minor High alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.50 |
lm870CminorLowOPTPowerThe value of this object provides the Minor Low alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.51 |
lm870CcurrentValueOPTPowerThe value of this object provides the Current value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.52 |
lm870CstateFlagOPTPowerThe value of this object provides the state
of the Optical Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.53 |
lm870CminValueOPTPowerThe value of this object provides the minimum value
the Optical Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.54 |
lm870CmaxValueOPTPowerThe value of this object provides the maximum value
the Optical Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.55 |
lm870CalarmStateOPTPowerThe value of this object provides the curent alarm state of
the Optical Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.56 |
lm870ClabelLaserBiasThe value of this object provides the label of the
Laser Bias Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.57 |
lm870CuomLaserBiasThe value of this object provides the Unit of Measure of the
Laser Bias Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.58 |
lm870CmajorHighLaserBiasThe value of this object provides the Major High alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.59 |
lm870CmajorLowLaserBiasThe value of this object provides the Major Low alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.60 |
lm870CminorHighLaserBiasThe value of this object provides the Minor High alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.61 |
lm870CminorLowLaserBiasThe value of this object provides the Minor Low alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.62 |
lm870CcurrentValueLaserBiasThe value of this object provides the Current value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.63 |
lm870CstateFlagLaserBiasThe value of this object provides the state
of the Laser Bias Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.64 |
lm870CminValueLaserBiasThe value of this object provides the minimum value
the Laser Bias Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.65 |
lm870CmaxValueLaserBiasThe value of this object provides the maximum value
the Laser Bias Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.66 |
lm870CalarmStateLaserBiasThe value of this object provides the curent alarm state of
the Laser Bias Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.67 |
lm870ClabelTecCurrentThe value of this object provides the label of the
TEC Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.68 |
lm870CuomTecCurrentThe value of this object provides the Unit of Measure of the
TEC Current Analog parameter..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.69 |
lm870CmajorHighTecCurrentThe value of this object provides the Major High alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.70 |
lm870CmajorLowTecCurrentThe value of this object provides the Major Low alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.71 |
lm870CminorHighTecCurrentThe value of this object provides the Minor High alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.72 |
lm870CminorLowTecCurrentThe value of this object provides the Minor Low alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.73 |
lm870CcurrentValueTecCurrentThe value of this object provides the Current value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.74 |
lm870CstateFlagTecCurrentThe value of this object provides the state
of the TEC Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.75 |
lm870CminValueTecCurrentThe value of this object provides the minimum value
the TEC Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.76 |
lm870CmaxValueTecCurrentThe value of this object provides the maximum value
the TEC Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.77 |
lm870CalarmStateTecCurrentThe value of this object provides the curent alarm state of
the TEC Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.78 |
lm870ClabelOmiAlarmSetpointThe value of this object provides the label of the
OMI Offset Alarm Setpoint Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.79 |
lm870CuomOmiAlarmSetpointThe value of this object provides the Unit of Measure of the
OMI Offset Alarm Setpoint Analog parameter..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.2.1.80 |
lm870CmajorHighOmiAlarmSetpointThe value of this object provides the Major High alarm value
of the OMI Offset Alarm Setpoint Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.81 |
lm870CmajorLowOmiAlarmSetpointThe value of this object provides the Major Low alarm value
of the OMI Offset Alarm Setpoint Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.82 |
lm870CminorHighOmiAlarmSetpointThe value of this object provides the Minor High alarm value
of the OMI Offset Alarm Setpoint Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.83 |
lm870CminorLowOmiAlarmSetpointThe value of this object provides the Minor Low alarm value
of the OMI Offset Alarm Setpoint Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.84 |
lm870CcurrentValueOmiAlarmSetpointThe value of this object provides the Current value
of the OMI Offset Alarm Setpoint Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.85 |
lm870CstateFlagOmiAlarmSetpointThe value of this object provides the state
of the OMI Offset Alarm Setpoint Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.86 |
lm870CminValueOmiAlarmSetpointThe value of this object provides the minimum value
the OMI Offset Alarm Setpoint Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.87 |
lm870CmaxValueOmiAlarmSetpointThe value of this object provides the maximum value
the OMI Offset Alarm Setpoint Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.10.2.1.88 |
lm870CalarmStateOmiAlarmSetpointThe value of this object provides the curent alarm state of
the OMI Offset Alarm Setpoint Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.2.1.89 |
gx2lm870CDigitalTableThis table contains gx2Lm870C specific parameters with
discrete values. SEQUENCE OF Gx2Lm870CDigitalEntry .1.3.6.1.4.1.1166.6.1.2.10.3 |
gx2lm870CDigitalEntryThis list contains digital parameters and descriptions. Gx2Lm870CDigitalEntry .1.3.6.1.4.1.1166.6.1.2.10.3.2 |
gx2Lm870CDigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.3.2.1 |
lm870ClabelOMIOffsetAlarmsThe value of this object provides the label of the
OMI Offset Alarm mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.3.2.2 |
lm870CenumOMIOffsetAlarmsThe value of this object represents the Enumeration values
possible for the OMI Offset Alarm modeDigital parameter. Each Enumerated
values is separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.3.2.3 |
lm870CvalueOMIOffsetAlarmsThe value of this object is the current value of the parameter. Note that the value to be read
will always be 1 or 2 because the set value (3) is always changed to the on
value (2) by the firmwarerw Enumeration .1.3.6.1.4.1.1166.6.1.2.10.3.2.4 |
lm870CstateFlagOMIOffsetAlarmsThe value of this object provides the state
of the OMI Offset Alarm mode Digital parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.3.2.5 |
lm870ClabelFactoryDefaultThe value of this object provides the label of the
Reset to Factory Default Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.3.2.6 |
lm870CenumFactoryDefaultThe value of this object represents the Enumeration values
possible for the Reste to Factory Default Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.3.2.7 |
lm870CvalueFactoryDefaultThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.10.3.2.8 |
lm870CstateFlagFactoryDefaultThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.3.2.9 |
lm870ClabelOMISetpointThe value of this object provides the label of the
OMI Setpoint Digital parameter.roobsolete DisplayString .1.3.6.1.4.1.1166.6.1.2.10.3.2.10 |
lm870CenumOMISetpointThe value of this object represents the Enumeration values
possible for the OMI Setpoint Digital parameter. Each Enumerated
values is separated by a common. The first value has a enumerated value of 1.roobsolete DisplayString .1.3.6.1.4.1.1166.6.1.2.10.3.2.11 |
lm870CvalueOMISetpointThe value of this object is the current value of the OMI Setpoint parameter.roobsolete INTEGER .1.3.6.1.4.1.1166.6.1.2.10.3.2.12 |
lm870CstateFlagOMISetpointThe value of this object provides the state
of the OMI Setpoint Digital parameter. (0-Hidden
1-Read-Only, 2-Updateable).roobsolete Enumeration .1.3.6.1.4.1.1166.6.1.2.10.3.2.13 |
gx2lm870CStatusTableThis table contains gx2Lm870C specific parameters with
current values. SEQUENCE OF Gx2Lm870CStatusEntry .1.3.6.1.4.1.1166.6.1.2.10.4 |
gx2lm870CStatusEntryThis list contains Status parameters and descriptions. Gx2Lm870CStatusEntry .1.3.6.1.4.1.1166.6.1.2.10.4.3 |
gx2Lm870CStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.4.3.1 |
lm870ClabelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.4.3.2 |
lm870CvalueBootThe value of this object provides the current value of
the boot status parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.3 |
lm870CstateflagBootThe value of this object provides the state
of the the boot status parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.4 |
lm870ClabelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.4.3.5 |
lm870CvalueFlashThe value of this object provides the current value of
the Flash Status parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.6 |
lm870CstateflagFlashThe value of this object provides the state current
of the the Flash Status parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.7 |
lm870ClabelRFOverloadThe value of this object provides the label for the
RF Overload Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.4.3.8 |
lm870CvalueRFOverloadThe value of this object provides the current value of
the RF Overload parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.9 |
lm870CstateflagRFOverloadThe value of this object provides the current state
of the RF Overload parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.10 |
lm870ClabelRFPowerThe value of this object provides the label for the
RF Power Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.4.3.11 |
lm870CvalueRFPowerThe value of this object provides the current value of
the RF Power parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.12 |
lm870CstateflagRFPowerThe value of this object provides the current state
of the RF Power parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.13 |
lm870ClabelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.4.3.14 |
lm870CvalueFactoryDataCRCThe value of this object provides the current value of
the Factory Data CRC parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.15 |
lm870CstateflagFactoryDataCRCThe value of this object provides the current state
of the the Factory Data CRC parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.16 |
lm870ClabelAlarmDataCrcThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.4.3.17 |
lm870CvalueAlarmDataCrcThe value of this object provides the current value of
the Alarm Data Crc parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.18 |
lm870CstateflagAlarmDataCrcThe value of this object provides the current state
of the the Alarm Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.19 |
lm870ClabelModSetDataCRCThe value of this object provides the label of the
Module Settings Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.4.3.20 |
lm870CvalueModSetDataCRCThe value of this object provides the current value of
the Module Settings Data Crc parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.21 |
lm870CstateflagModSetDataCRCThe value of this object provides the current state
of the the Module Settings Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.22 |
lm870ClabelOptCalDataCRCThe value of this object provides the label of the
Optical Calibration Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.4.3.23 |
lm870CvalueOptCalDataCRCThe value of this object provides the current value of
the Optical Calibration Data Crc parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.24 |
lm870CstateflagOptCalDataCRCThe value of this object provides the current state
of the the Optical Calibration Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.25 |
lm870ClabelRFCalDataCRCThe value of this object provides the label of the
RF Calibration Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.4.3.26 |
lm870CvalueRFCalDataCRCThe value of this object provides the current value of
the RF Calibration Data Crc parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.27 |
lm870CstateflagRFCalDataCRCThe value of this object provides the current state
of the the RF Calibration Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.4.3.28 |
gx2lm870CFactoryTableThis table contains gx2Lm870C specific parameters with
stored factory values. SEQUENCE OF Gx2Lm870CFactoryEntry .1.3.6.1.4.1.1166.6.1.2.10.5 |
gx2lm870CFactoryEntryThis list contains Factory parameters and descriptions. Gx2Lm870CFactoryEntry .1.3.6.1.4.1.1166.6.1.2.10.5.4 |
gx2Lm870CFactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.5.4.1 |
lm870CbootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.5.4.2 |
lm870CbootStatusByteThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.5.4.3 |
lm870Cbank1CRCThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.5.4.4 |
lm870Cbank2CRCThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.5.4.5 |
lm870CprgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.5.4.6 |
lm870CfactoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.5.4.7 |
lm870CcalculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.10.5.4.8 |
lm870ChourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.5.4.9 |
lm870CflashPrgCntAThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.5.4.10 |
lm870CflashPrgCntBThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.10.5.4.11 |
lm870CflashBankARevThis object provides the revision of flash bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.10.5.4.12 |