Home/Catalog/OMNI-gx2LME-MIB

OMNI-gx2LME-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for OMNI-gx2LME-MIB.

220
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

220 total
Object Name
trapLMEConfigChangeIntegerThis trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.1
trapLMEConfigChangeDisplayStringThis trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.2
trapLMERFInputAlarmThis trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.3
trapLMERFOverloadAlarmThis trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.4
trapLMERFOffsetAlarmThis trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.5
trapLMEOpticalPowerAlarmThis trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.6
trapLMELaserBiasAlarmThis trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.7
trapLMELaserTempAlarmThis trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.8
trapLMETECCurrentAlarmThis trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.9
trapLMEFanCurrentAlarmThis trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.10
trapLME12vAlarmThis trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.11
trapLMEModuleTempAlarmThis trap is issued when the Laser Module Temperature goes out of range.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.12
trapLMEFlashAlarmThis trap is issued when the Laser Modules detects an error during Flash memory operations.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.13
trapLMELaserBiasCntLoopAlarmThis trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.14
trapLMEBankBootAlarmThis trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.15
trapLMELaserBiasCntLoopInitAlarmThis trap is issued when the Laser Bias Control loop init fails.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.16
trapLMERFParamInitAlarmThis trap is issued when the RF parameter Init fails.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.17
trapLMETECParamInitAlarmThis trap is issued when the TEC Parameter Init fails.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.18
trapLMEAttnTableInitAlarmThis trap is issued when the Attenuator Table Init fails.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.19
trapLMEPowerMeterTableInitAlarmThis trap is issued when the Power Meter Table Init fails.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.20
trapLMELaserDataCRCAlarmThis trap is issued when the Laser Data CRC is incorrect.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.21
trapLMEAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.22
trapLMEFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.23
trapLMEUserRFOffAlarmThis trap is issued when the the User RF is turned off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.24
trapLMEUserOpticalOffAlarmThis trap is issued when the User Optical Power is turned off.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.25
trapLMEResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs.
TRAP-TYPE
.1.3.6.1.4.1.1166.6.1.2.27.0.26
gx2lmeDescriptor
OBJECT IDENTIFIER
.1.3.6.1.4.1.1166.6.1.2.27.1
RFC1155-SMI
Unknown
.1.3.6.1.4.1.1166.6.1.2.27.1
gx2lmeAnalogTableThis table contains gx2LmE specific parameters with nominal and current values.
SEQUENCE OF Gx2lmeAnalogEntry
.1.3.6.1.4.1.1166.6.1.2.27.2
gx2lmeAnalogEntryThis list contains the analog parameters and descriptions.
Gx2lmeAnalogEntry
.1.3.6.1.4.1.1166.6.1.2.27.2.1
gx2lmeAnalogTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.2.1.1
lmelabelOffsetNomMonitorThe value of this object provides the label of the Offset Monitor Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.2
lmeuomOffsetNomMonitorThe value of this object provides the Unit of Measure of the Offset Monitor Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.3
lmemajorHighOffsetNomMonitorThe value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.4
lmemajorLowOffsetNomMonitorThe value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.5
lmeminorHighOffsetNomMonitorThe value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.6
lmeminorLowOffsetNomMonitorThe value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.7
lmecurrentValueOffsetNomMonitorThe value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.8
lmestateFlagOffsetNomMonitorThe value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.9
lmeminValueOffsetNomMonitorThe value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.10
lmemaxValueOffsetNomMonitorThe value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.11
lmealarmStateOffsetNomMonitorThe value of this object provides the curent alarm state of the Offset Monitor Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.12
lmelabelOffsetNomCntThe value of this object provides the label of the Offset Control Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.13
lmeuomOffsetNomCntThe value of this object provides the label of the Offset Control Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.14
lmemajorHighOffsetNomCntThe value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.15
lmemajorLowOffsetNomCntThe value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.16
lmeminorHighOffsetNomCntThe value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.17
lmeminorLowOffsetNomCntThe value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.18
lmecurrentValueOffsetNomCntThe value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.rw
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.19
lmestateFlagOffsetNomCntThe value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.20
lmeminValueOffsetNomCntThe value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.21
lmemaxValueOffsetNomCntThe value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.22
lmealarmStateOffsetNomCntThe value of this object provides the curent alarm state of the Offset Control Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.23
lmelabelRelAttenSettingThe value of this object provides the label of the Attenuator Setting Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.24
lmeuomRelAttenSettingThe value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.25
lmemajorHighRelAttenSettingThe value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.26
lmemajorLowRelAttenSettingThe value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.27
lmeminorHighRelAttenSettingThe value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.28
lmeminorLowRelAttenSettingThe value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.29
lmecurrentValueRelAttenSettingThe value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.rw
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.30
lmestateFlagRelAttenSettingThe value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.31
lmeminValueRelAttenSettingThe value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.32
lmemaxValueRelAttenSettingThe value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.33
lmealarmStateRelAttenSettingThe value of this object provides the curent alarm state of the Attenuator Setting Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.34
lmelabelOptPowerThe value of this object provides the label of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.35
lmeuomOptPowerThe value of this object provides the Unit of Measure of the Optical Power Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.36
lmemajorHighOptPowerThe value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.37
lmemajorLowOptPowerThe value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.38
lmeminorHighOptPowerThe value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.39
lmeminorLowOptPowerThe value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.40
lmecurrentValueOptPowerThe value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.41
lmestateFlagOptPowerThe value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.42
lmeminValueOptPowerThe value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.43
lmemaxValueOptPowerThe value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.44
lmealarmStateOptPowerThe value of this object provides the curent alarm state of the Optical Power Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.45
lmelabelLaserBiasThe value of this object provides the label of the Laser Bias Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.46
lmeuomLaserBiasThe value of this object provides the Unit of Measure of the Laser Bias Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.47
lmemajorHighLaserBiasThe value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.48
lmemajorLowLaserBiasThe value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.49
lmeminorHighLaserBiasThe value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.50
lmeminorLowLaserBiasThe value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.51
lmecurrentValueLaserBiasThe value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.52
lmestateFlagLaserBiasThe value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.53
lmeminValueLaserBiasThe value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.54
lmemaxValueLaserBiasThe value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.55
lmealarmStateLaserBiasThe value of this object provides the curent alarm state of the Laser Bias Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.56
lmelabelTecCurrentThe value of this object provides the label of the TEC Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.57
lmeuomTecCurrentThe value of this object provides the Unit of Measure of the TEC Current Analog parameter..ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.58
lmemajorHighTecCurrentThe value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.59
lmemajorLowTecCurrentThe value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.60
lmeminorHighTecCurrentThe value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.61
lmeminorLowTecCurrentThe value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.62
lmecurrentValueTecCurrentThe value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.63
lmestateFlagTecCurrentThe value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.64
lmeminValueTecCurrentThe value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.65
lmemaxValueTecCurrentThe value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.66
lmealarmStateTecCurrentThe value of this object provides the curent alarm state of the TEC Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.67
lmelabelLaserTempThe value of this object provides the label of the Laser Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.68
lmeuomLaserTempThe value of this object provides the Unit of Measure of the Laser Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.69
lmemajorHighLaserTempThe value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.70
lmemajorLowLaserTempThe value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.71
lmeminorHighLaserTempThe value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.72
lmeminorLowLaserTempThe value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.73
lmecurrentValueLaserTempThe value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.74
lmestateFlagLaserTempThe value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.75
lmeminValueLaserTempThe value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.76
lmemaxValueLaserTempThe value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.77
lmealarmStateLaserTempThe value of this object provides the curent alarm state of the Laser Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.78
lmelabelModuleTempThe value of this object provides the label of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.79
lmeuomModuleTempThe value of this object provides the Unit of Measure of the Module Temperature Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.80
lmemajorHighModuleTempThe value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.81
lmemajorLowModuleTempThe value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.82
lmeminorHighModuleTempThe value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.83
lmeminorLowModuleTempThe value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.84
lmecurrentValueModuleTempThe value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.85
lmestateFlagModuleTempThe value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.86
lmeminValueModuleTempThe value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.87
lmemaxValueModuleTempThe value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.88
lmealarmStateModuleTempThe value of this object provides the curent alarm state of the Module Temperature Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.89
lmelabelFanCurrentThe value of this object provides the label of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.90
lmeuomFanCurrentThe value of this object provides the Unit of Measure of the Fan Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.91
lmemajorHighFanCurrentThe value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.92
lmemajorLowFanCurrentThe value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.93
lmeminorHighFanCurrentThe value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.94
lmeminorLowFanCurrentThe value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.95
lmecurrentValueFanCurrentThe value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.96
lmestateFlagFanCurrentThe value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.97
lmeminValueFanCurrentThe value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.98
lmemaxValueFanCurrentThe value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.99
lmealarmStateFanCurrentThe value of this object provides the curent alarm state of the Fan Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.100
lmelabel12VoltThe value of this object provides the label of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.101
lmeuom12VoltThe value of this object provides the Unit of Measure of the 12v Current Analog parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.2.1.102
lmemajorHigh12VoltThe value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.103
lmemajorLow12VoltThe value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.104
lmeminorHigh12VoltThe value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.105
lmeminorLow12VoltThe value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.106
lmecurrentValue12VoltThe value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.107
lmestateFlag12VoltThe value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.108
lmeminValue12VoltThe value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.109
lmemaxValue12VoltThe value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.ro
Float
.1.3.6.1.4.1.1166.6.1.2.27.2.1.110
lmealarmState12VoltThe value of this object provides the curent alarm state of the 12v Current Analog parameter.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.2.1.111
gx2lmeDigitalTableThis table contains gx2LmE specific parameters with nominal and current values.
SEQUENCE OF Gx2lmeDigitalEntry
.1.3.6.1.4.1.1166.6.1.2.27.3
gx2lmeDigitalEntryThis list contains digital parameters and descriptions.
Gx2lmeDigitalEntry
.1.3.6.1.4.1.1166.6.1.2.27.3.2
gx2lmeDigitalTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.3.2.1
lmelabelRfInputThe value of this object provides the label of the RF Input Control Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.2
lmeenumRfInputThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.3
lmevalueRfInputThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.4
lmestateflagRfInputThe value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.5
lmelabelOptOutputThe value of this object provides the label of the Optical Output Control Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.6
lmeenumOptOutputThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.7
lmevalueOptOutputThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.8
lmestateflagOptOutputThe value of this object provides the lmestate of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.9
lmelabelLaserModeThe value of this object provides the label of the Laser Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.10
lmeenumLaserModeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.11
lmevalueLaserModeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.12
lmestateflagLaserModeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.13
lmelabelLaserSecModeThe value of this object provides the label of the Laser Secondary Mode Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.14
lmeenumLaserSecModeThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.15
lmevalueLaserSecModeThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.16
lmestateflagLaserSecModeThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.17
lmelabelVideoOffsetThe value of this object provides the label of the Video Offset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.18
lmeenumVideoOffsetThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1..ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.19
lmevalueVideoOffsetThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.20
lmestateflagVideoOffsetThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.21
lmelabelFactoryDefaultThe value of this object provides the label of the Factory Default Reset Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.22
lmeenumFactoryDefaultThe value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.23
lmevalueFactoryDefaultThe value of this object is the current value of the parameter.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.24
lmestateflagFactoryDefaultThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.25
lmelabelFiberLengthThis object is only used for the LC1000 device family. The value of this object provides the label for the Fiber Length Digital parameter .ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.26
lmeenumFiberLengthThis object is only used for the LC1000 device family. The value of this object represents the Enumeration values possible for the Digital parameter. The range for fiber length selection is from 6 to 25km, where 6km is represented with a 1 and 25 with a 19.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.27
lmevalueFiberLengthThis object is only used for the LC1000 device family. The value of this object is the current value of the parameter. It is used to set fiber length. The value range for this object is: 0 to 30 Km.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.28
lmestateflagFiberLengthThis object is only used for the LC1000 device family. The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.29
lmelabelConditioningUnitThis object is only used for the LC1000 device family. The value of this object provides the label for the Conditioning Unit Digital parameter .ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.30
lmeenumConditioningUnitThis object is only used for the LC1000 device family. The value of this object represents the Enumeration values possible for the Digital parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.3.2.31
lmevalueConditioningUnitThis object is only used for the LC1000 device family. The value of this object is the current value of the parameter. It is used to normalize the output by -3db when a conditioning unit is being used in the system.rw
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.32
lmestateflagConditioningUnitThis object is only used for the LC1000 device family. The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.3.2.33
gx2lmeStatusTableThis table contains gx2LmE specific parameters with nominal and current values.
SEQUENCE OF Gx2lmeStatusEntry
.1.3.6.1.4.1.1166.6.1.2.27.4
gx2lmeStatusEntryThis list contains Status parameters and descriptions.
Gx2lmeStatusEntry
.1.3.6.1.4.1.1166.6.1.2.27.4.3
gx2lmeStatusTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.4.3.1
lmelabelBootThe value of this object provides the label of the Boot Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.4.3.2
lmevalueBootThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.3
lmestateflagBootThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.4
lmelabelFlashThe value of this object provides the label of the Flash Status Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.4.3.5
lmevalueFlashThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.6
lmestateflagFlashThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.7
lmelabelFactoryDataCRCThe value of this object provides the label of the Factory Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.4.3.8
lmevalueFactoryDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.9
lmestateflagFactoryDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.10
lmelabelLaserDataCRCThe value of this object provides the label of the Laser Data CRC Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.4.3.11
lmevalueLaserDataCRCThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.12
lmestateflagLaserDataCRCThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.13
lmelabelAlarmDataCrcThe value of this object provides the label of the Alarm Data Crc parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.4.3.14
lmevalueAlarmDataCrcThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.15
lmestateflagAlarmDataCrcThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.16
lmelabelHWStatusThe value of this object provides the label of the Laser Drive Level Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.4.3.17
lmevalueHWStatusThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.18
lmestateflagHWStatusThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.19
lmelabelRFInputStatusThe value of this object provides the label of the RF Input Status parameter.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.4.3.20
lmevalueRFInputStatusThe value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.21
lmestateflagRFInputStatusThe value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.4.3.22
gx2lmeFactoryTableThis table contains gx2LmE specific parameters with nominal and current values.
SEQUENCE OF Gx2lmeFactoryEntry
.1.3.6.1.4.1.1166.6.1.2.27.5
gx2lmeFactoryEntryThis list contains Factory parameters and descriptions.
Gx2lmeFactoryEntry
.1.3.6.1.4.1.1166.6.1.2.27.5.4
gx2lmeFactoryTableIndexThe value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.5.4.1
lmebootControlByteValueThe value of this object indicates which bank the firmware is currently being boot from.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.5.4.2
lmebootStatusByteValueThis object indicates the status of the last bootro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.5.4.3
lmebank1CRCValueThis object provides the CRC code of bank 0.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.5.4.4
lmebank2CRCValueThis object provides the CRC code of bank 1.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.5.4.5
lmeprgEEPROMByteValueThis object indicates if the EEPROM has been programmedro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.5.4.6
lmefactoryCRCValueThis object provides the CRC code for the Factory data.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.5.4.7
lmecalculateCRCValueThis object indicates which of the Emnums will have the CRC calculated.ro
Enumeration
.1.3.6.1.4.1.1166.6.1.2.27.5.4.8
lmehourMeterValueThis object provides the hour meter reading of the module.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.5.4.9
lmeflashPrgCntAValueThis object provides the number of times Bank 1 flash has been programmed.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.5.4.10
lmeflashPrgCntBValueThis object provides the number of times Bank 1 flash has been programmed.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.5.4.11
lmeflashBankARevValueThis object provides the revision of flash bank 0.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.5.4.12
lmeflashBankBRevValueThis object provides the revision of flash bank 1.ro
DisplayString
.1.3.6.1.4.1.1166.6.1.2.27.5.4.13
gx2Lm1000EHoldTimeTableThis table contains gx2Lm1000E specific parameters with nominal and current values.
SEQUENCE OF Gx2Lm1000EHoldTimeEntry
.1.3.6.1.4.1.1166.6.1.2.27.6
gx2Lm1000EHoldTimeEntryThis list contains digital product class and the associated RF channel parameters and descriptions.
Gx2Lm1000EHoldTimeEntry
.1.3.6.1.4.1.1166.6.1.2.27.6.5
gx2Lm1000EHoldTimeTableIndexThe value of this object is the index of the data object.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.6.5.1
gx2Lm1000EHoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.6.5.2
gx2Lm1000EHoldTimeDataThe value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.rw
INTEGER
.1.3.6.1.4.1.1166.6.1.2.27.6.5.3
OMNI-gx2LME-MIB - SNMP MIB Reference | MIBs Explorer