OMNI-gx2LM-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
212
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
212 total| Object Name |
|---|
trapLMConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.1 |
trapLMConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.2 |
trapLMRFInputAlarmThis trap is issued when the Laser Modules RF input parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.3 |
trapLMRFOverloadAlarmThis trap is issued when the Laser Modules RF overload parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.4 |
trapLMRFOffsetAlarmThis trap is issued when the Laser Modules RF Offset parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.5 |
trapLMOpticalPowerAlarmThis trap is issued when the Laser Modules Optical Power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.6 |
trapLMLaserBiasAlarmThis trap is issued when the Laser Bias parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.7 |
trapLMLaserTempAlarmThis trap is issued when the Laser Temperature parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.8 |
trapLMTECCurrentAlarmThis trap is issued when the Laser Modules TEC Current parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.9 |
trapLMFanCurrentAlarmThis trap is issued when the Laser Modules Fan Current
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.10 |
trapLM12vAlarmThis trap is issued when the Laser Modules 12 Volt parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.11 |
trapLMModuleTempAlarmThis trap is issued when the Laser Module Temperature goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.12 |
trapLMFlashAlarmThis trap is issued when the Laser Modules detects an error during
Flash memory operations. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.13 |
trapLMLaserBiasCntLoopAlarmThis trap is issued when the Laser Modules detects an error in its Laser Bias control loop
operation. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.14 |
trapLMBankBootAlarmThis trap is issued when the Laser Modules detects an error while booting
from bank 0 or bank 1. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.15 |
trapLMLaserBiasCntLoopInitAlarmThis trap is issued when the Laser Bias Control loop init fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.16 |
trapLMRFParamInitAlarmThis trap is issued when the RF parameter Init fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.17 |
trapLMTECParamInitAlarmThis trap is issued when the TEC Parameter Init fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.18 |
trapLMAttnTableInitAlarmThis trap is issued when the Attenuator Table Init fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.19 |
trapLMPowerMeterTableInitAlarmThis trap is issued when the Power Meter Table Init fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.20 |
trapLMLaserDataCRCAlarmThis trap is issued when the Laser Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.21 |
trapLMAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.22 |
trapLMFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.23 |
trapLMUserRFOffAlarmThis trap is issued when the the User RF is turned off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.24 |
trapLMUserOpticalOffAlarmThis trap is issued when the User Optical Power is turned off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.25 |
trapLMResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.4.0.26 |
gx2lmDescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.4.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.4.1 |
gx2lmAnalogTableThis table contains gx2Lm specific parameters with
nominal and current values. SEQUENCE OF Gx2lmAnalogEntry .1.3.6.1.4.1.1166.6.1.2.4.2 |
gx2lmAnalogEntryThis list contains the analog parameters and descriptions. Gx2lmAnalogEntry .1.3.6.1.4.1.1166.6.1.2.4.2.1 |
gx2lmAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.2.1.1 |
labelOffsetNomMonitorThe value of this object provides the label of the
Offset Monitor Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.2 |
uomOffsetNomMonitorThe value of this object provides the Unit of Measure of the
Offset Monitor Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.3 |
majorHighOffsetNomMonitorThe value of this object provides the Major High alarm value
of the Offset Monitor Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.4 |
majorLowOffsetNomMonitorThe value of this object provides the Major Low alarm value
of the Offset Monitor Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.5 |
minorHighOffsetNomMonitorThe value of this object provides the Minor High alarm value
of the Offset Monitor Analog parameter.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.6 |
minorLowOffsetNomMonitorThe value of this object provides the Minor Low alarm value
of the Offset Monitor Analog parameter.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.7 |
currentValueOffsetNomMonitorThe value of this object provides the Current value
of the Offset Monitor Analog parameter.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.8 |
stateFlagOffsetNomMonitorThe value of this object provides the state
of the Offset Monitor Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable)ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.9 |
minValueOffsetNomMonitorThe value of this object provides the minimum value
the Offset Monitor Analog parameter can achive.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.10 |
maxValueOffsetNomMonitorThe value of this object provides the maximum value
the Offset Monitor Analog parameter can achive.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.11 |
alarmStateOffsetNomMonitorThe value of this object provides the curent alarm state of
the Offset Monitor Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.12 |
labelOffsetNomCntThe value of this object provides the label of the
Offset Control Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.13 |
uomOffsetNomCntThe value of this object provides the label of the
Offset Control Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.14 |
majorHighOffsetNomCntThe value of this object provides the Major High alarm value
of the Offset Control Analog parameter.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.15 |
majorLowOffsetNomCntThe value of this object provides the Major Low alarm value
of the Offset Control Analog parameter.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.16 |
minorHighOffsetNomCntThe value of this object provides the Minor High alarm value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.17 |
minorLowOffsetNomCntThe value of this object provides the Minor Low alarm value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.18 |
currentValueOffsetNomCntThe value of this object provides the Current value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.19 |
stateFlagOffsetNomCntThe value of this object provides the state
of the Offset Control Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable)ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.20 |
minValueOffsetNomCntThe value of this object provides the minimum value
the Offset Control Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.21 |
maxValueOffsetNomCntThe value of this object provides the maximum value
the Offset Control Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.22 |
alarmStateOffsetNomCntThe value of this object provides the curent alarm state of
the Offset Control Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.23 |
labelRelAttenSettingThe value of this object provides the label of the
Attenuator Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.24 |
uomRelAttenSettingThe value of this object provides the Unit of Measure of the
Attenuator Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.25 |
majorHighRelAttenSettingThe value of this object provides the Major High alarm value
of the Attenuator Setting Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.26 |
majorLowRelAttenSettingThe value of this object provides the Major Low alarm value
of the Attenuator Setting Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.27 |
minorHighRelAttenSettingThe value of this object provides the Minor High alarm value
of the Attenuator Setting Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.28 |
minorLowRelAttenSettingThe value of this object provides the Minor Low alarm value
of the Attenuator Setting Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.29 |
currentValueRelAttenSettingThe value of this object provides the Current value
of the Attenuator Setting Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.30 |
stateFlagRelAttenSettingThe value of this object provides the state
of the Attenuator Setting Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.31 |
minValueRelAttenSettingThe value of this object provides the minimum value
the Attenuator Setting Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.32 |
maxValueRelAttenSettingThe value of this object provides the maximum value
the Attenuator Setting Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.33 |
alarmStateRelAttenSettingThe value of this object provides the curent alarm state of
the Attenuator Setting Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.34 |
labelOptPowerThe value of this object provides the label of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.35 |
uomOptPowerThe value of this object provides the Unit of Measure of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.36 |
majorHighOptPowerThe value of this object provides the Major High alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.37 |
majorLowOptPowerThe value of this object provides the Major Low alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.38 |
minorHighOptPowerThe value of this object provides the Minor High alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.39 |
minorLowOptPowerThe value of this object provides the Minor Low alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.40 |
currentValueOptPowerThe value of this object provides the Current value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.41 |
stateFlagOptPowerThe value of this object provides the state
of the Optical Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.42 |
minValueOptPowerThe value of this object provides the minimum value
the Optical Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.43 |
maxValueOptPowerThe value of this object provides the maximum value
the Optical Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.44 |
alarmStateOptPowerThe value of this object provides the curent alarm state of
the Optical Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.45 |
labelLaserBiasThe value of this object provides the label of the
Laser Bias Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.46 |
uomLaserBiasThe value of this object provides the Unit of Measure of the
Laser Bias Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.47 |
majorHighLaserBiasThe value of this object provides the Major High alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.48 |
majorLowLaserBiasThe value of this object provides the Major Low alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.49 |
minorHighLaserBiasThe value of this object provides the Minor High alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.50 |
minorLowLaserBiasThe value of this object provides the Minor Low alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.51 |
currentValueLaserBiasThe value of this object provides the Current value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.52 |
stateFlagLaserBiasThe value of this object provides the state
of the Laser Bias Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.53 |
minValueLaserBiasThe value of this object provides the minimum value
the Laser Bias Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.54 |
maxValueLaserBiasThe value of this object provides the maximum value
the Laser Bias Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.55 |
alarmStateLaserBiasThe value of this object provides the curent alarm state of
the Laser Bias Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.56 |
labelTecCurrentThe value of this object provides the label of the
TEC Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.57 |
uomTecCurrentThe value of this object provides the Unit of Measure of the
TEC Current Analog parameter..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.58 |
majorHighTecCurrentThe value of this object provides the Major High alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.59 |
majorLowTecCurrentThe value of this object provides the Major Low alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.60 |
minorHighTecCurrentThe value of this object provides the Minor High alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.61 |
minorLowTecCurrentThe value of this object provides the Minor Low alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.62 |
currentValueTecCurrentThe value of this object provides the Current value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.63 |
stateFlagTecCurrentThe value of this object provides the state
of the TEC Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.64 |
minValueTecCurrentThe value of this object provides the minimum value
the TEC Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.65 |
maxValueTecCurrentThe value of this object provides the maximum value
the TEC Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.66 |
alarmStateTecCurrentThe value of this object provides the curent alarm state of
the TEC Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.67 |
labelLaserTempThe value of this object provides the label of the
Laser Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.68 |
uomLaserTempThe value of this object provides the Unit of Measure of the
Laser Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.69 |
majorHighLaserTempThe value of this object provides the Major High alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.70 |
majorLowLaserTempThe value of this object provides the Major Low alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.71 |
minorHighLaserTempThe value of this object provides the Minor High alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.72 |
minorLowLaserTempThe value of this object provides the Minor Low alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.73 |
currentValueLaserTempThe value of this object provides the Current value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.74 |
stateFlagLaserTempThe value of this object provides the state
of the Laser Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.75 |
minValueLaserTempThe value of this object provides the minimum value
the Laser Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.76 |
maxValueLaserTempThe value of this object provides the maximum value
the Laser Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.77 |
alarmStateLaserTempThe value of this object provides the curent alarm state of
the Laser Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.78 |
labelModuleTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.79 |
uomModuleTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.80 |
majorHighModuleTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.81 |
majorLowModuleTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.82 |
minorHighModuleTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.83 |
minorLowModuleTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.84 |
currentValueModuleTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.85 |
stateFlagModuleTempThe value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.86 |
minValueModuleTempThe value of this object provides the minimum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.87 |
maxValueModuleTempThe value of this object provides the maximum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.88 |
alarmStateModuleTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.89 |
labelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.90 |
uomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.91 |
majorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.92 |
majorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.93 |
minorHighFanCurrentThe value of this object provides the Minor High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.94 |
minorLowFanCurrentThe value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.95 |
currentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.96 |
stateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.97 |
minValueFanCurrentThe value of this object provides the minimum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.98 |
maxValueFanCurrentThe value of this object provides the maximum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.99 |
alarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.100 |
label12VoltThe value of this object provides the label of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.101 |
uom12VoltThe value of this object provides the Unit of Measure of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.2.1.102 |
majorHigh12VoltThe value of this object provides the Major High alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.103 |
majorLow12VoltThe value of this object provides the Major Low alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.104 |
minorHigh12VoltThe value of this object provides the Minor High alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.105 |
minorLow12VoltThe value of this object provides the Minor Low alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.106 |
currentValue12VoltThe value of this object provides the Current value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.107 |
stateFlag12VoltThe value of this object provides the state
of the 12v Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.108 |
minValue12VoltThe value of this object provides the minimum value
the 12v Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.109 |
maxValue12VoltThe value of this object provides the maximum value
the 12v Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.4.2.1.110 |
alarmState12VoltThe value of this object provides the curent alarm state of
the 12v Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.2.1.111 |
gx2lmDigitalTableThis table contains gx2Lm specific parameters with
nominal and current values. SEQUENCE OF Gx2lmDigitalEntry .1.3.6.1.4.1.1166.6.1.2.4.3 |
gx2lmDigitalEntryThis list contains digital parameters and descriptions. Gx2lmDigitalEntry .1.3.6.1.4.1.1166.6.1.2.4.3.2 |
gx2lmDigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.3.2.1 |
labelRfInputThe value of this object provides the label of the
RF Input Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.2 |
enumRfInputThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.3 |
valueRfInputThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.4 |
stateflagRfInputThe value of this object provides the state
of the RF Input Control Digital parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.5 |
labelOptOutputThe value of this object provides the label of the
Optical Output Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.6 |
enumOptOutputThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.7 |
valueOptOutputThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.8 |
stateflagOptOutputThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.9 |
labelLaserModeThe value of this object provides the label of the
Laser Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.10 |
enumLaserModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.11 |
valueLaserModeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.12 |
stateflagLaserModeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.13 |
labelLaserSecModeThe value of this object provides the label of the
Laser Secondary Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.14 |
enumLaserSecModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.15 |
valueLaserSecModeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.16 |
stateflagLaserSecModeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.17 |
labelVideoOffsetThe value of this object provides the label of the
Video Offset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.18 |
enumVideoOffsetThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.19 |
valueVideoOffsetThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.20 |
stateflagVideoOffsetThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.21 |
labelFactoryDefaultThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.22 |
enumFactoryDefaultThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.3.2.23 |
valueFactoryDefaultThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.24 |
stateflagFactoryDefaultThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.3.2.25 |
gx2lmStatusTableThis table contains gx2Lm specific parameters with
nominal and current values. SEQUENCE OF Gx2lmStatusEntry .1.3.6.1.4.1.1166.6.1.2.4.4 |
gx2lmStatusEntryThis list contains Status parameters and descriptions. Gx2lmStatusEntry .1.3.6.1.4.1.1166.6.1.2.4.4.3 |
gx2lmStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.4.3.1 |
labelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.4.3.2 |
valueBootThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.3 |
stateflagBootThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.4 |
labelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.4.3.5 |
valueFlashThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.6 |
stateflagFlashThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.7 |
labelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.4.3.8 |
valueFactoryDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.9 |
stateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.10 |
labelLaserDataCRCThe value of this object provides the label of the
Laser Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.4.3.11 |
valueLaserDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.12 |
stateflagLaserDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.13 |
labelAlarmDataCrcThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.4.3.14 |
valueAlarmDataCrcThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.15 |
stateflagAlarmDataCrcThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.16 |
labelHWStatusThe value of this object provides the label of the
Laser Drive Level Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.4.3.17 |
valueHWStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.18 |
stateflagHWStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.19 |
labelRFInputStatusThe value of this object provides the label of the
RF Input Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.4.3.20 |
valueRFInputStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.21 |
stateflagRFInputStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.4.3.22 |
gx2lmFactoryTableThis table contains gx2Lm specific parameters with
nominal and current values. SEQUENCE OF Gx2lmFactoryEntry .1.3.6.1.4.1.1166.6.1.2.4.5 |
gx2lmFactoryEntryThis list contains Factory parameters and descriptions. Gx2lmFactoryEntry .1.3.6.1.4.1.1166.6.1.2.4.5.4 |
gx2lmFactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.5.4.1 |
bootControlByteValueThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.5.4.2 |
bootStatusByteValueThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.5.4.3 |
bank1CRCValueThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.5.4.4 |
bank2CRCValueThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.5.4.5 |
prgEEPROMByteValueThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.5.4.6 |
factoryCRCValueThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.5.4.7 |
calculateCRCValueThis object indicates which of the Emnums will have the CRC calculated.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.4.5.4.8 |
hourMeterValueThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.5.4.9 |
flashPrgCntAValueThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.5.4.10 |
flashPrgCntBValueThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.5.4.11 |
flashBankARevValueThis object provides the revision of flash bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.5.4.12 |
flashBankBRevValueThis object provides the revision of flash bank 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.4.5.4.13 |
gx2Lm1000HoldTimeTableThis table contains gx2Lm1000 specific parameters with
nominal and current values. SEQUENCE OF Gx2Lm1000HoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.4.6 |
gx2Lm1000HoldTimeEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Lm1000HoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.4.6.5 |
gx2Lm1000HoldTimeTableIndexThe value of this object is the index of the data object.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.6.5.1 |
gx2Lm1000HoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.4.6.5.2 |
gx2Lm1000HoldTimeDataThe value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds.rw INTEGER .1.3.6.1.4.1.1166.6.1.2.4.6.5.3 |