OMNI-gx2Em870-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
160
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
160 total| Object Name |
|---|
trapEM870ConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.1 |
trapEM870ConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.2 |
trapEM870FanCurrentAlarmThis trap is issued when the Laser Modules Fan Current
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.3 |
trapEM87012vAlarmThis trap is issued when the Laser Modules 12 Volt parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.4 |
trapEM870ModuleTempAlarmThis trap is issued when the Module Temperature goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.5 |
trapEM870OmiOffsetAlarmThis trap is issued when the Laser Modules OMI level parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.6 |
trapEM870OpticalOutputPowerAlarmThis trap is issued when the Laser Modules Optical Output power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.7 |
trapEM870FlashAlarmThis trap is issued when the Laser Modules detects an error during
Flash memory operations. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.8 |
trapEM870BankBootAlarmThis trap is issued when the Laser Modules detects an error while booting
from bank 0 or bank 1. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.9 |
trapEM870AlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.10 |
trapEM870FactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.12.0.11 |
gx2Em870Descriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.12.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.12.1 |
gx2Em870AnalogTableThis table contains gx2Em870 specific parameters with
nominal and current values. SEQUENCE OF Gx2Em870AnalogEntry .1.3.6.1.4.1.1166.6.1.2.12.2 |
gx2Em870AnalogEntryThis list contains the analog parameters and descriptions. Gx2Em870AnalogEntry .1.3.6.1.4.1.1166.6.1.2.12.2.1 |
gx2Em870AnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.2.1.1 |
em870labelOpticalPowerThe value of this object provides the label of the
Optical Output Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.2 |
em870uomOpticalPowerThe value of this object provides the Unit of Measure of the
Optical Output Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.3 |
em870majorHighOpticalPowerThe value of this object provides the Major High alarm value
of the Optical Output Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.4 |
em870majorLowOpticalPowerThe value of this object provides the Major Low alarm value
of the Optical Output Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.5 |
em870minorHighOpticalPowerThe value of this object provides the Minor High alarm value
of the Optical Output Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.6 |
em870minorLowOpticalPowerThe value of this object provides the Minor Low alarm value
of the Optical Output Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.7 |
em870currentValueOpticalPowerThe value of this object provides the Current value
of the Optical Output Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.8 |
em870stateFlagOpticalPowerThe value of this object provides the state
of the Optical Output Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.9 |
em870minValueOpticalPowerThe value of this object provides the minimum value
the Optical Output Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.10 |
em870maxValueOpticalPowerThe value of this object provides the maximum value
the Optical Output Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.11 |
em870alarmStateOpticalPowerThe value of this object provides the curent alarm state of
the Optical Output Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.12 |
em870labelOmiOffsetThe value of this object provides the label of the
RF Input Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.13 |
em870uomOmiOffsetThe value of this object provides the Unit of Measure of the
RF Input Power Analog parameter..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.14 |
em870majorHighOmiOffsetThe value of this object provides the Major High alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.15 |
em870majorLowOmiOffsetThe value of this object provides the Major Low alarm value
of the RF Input Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.16 |
em870minorHighOmiOffsetThe value of this object provides the Minor High alarm value
of the RF Input Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.17 |
em870minorLowOmiOffsetThe value of this object provides the Minor Low alarm value
of the RF Input Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.18 |
em870currentValueOmiOffsetThe value of this object provides the Current value
of the RF Input Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
+99 dB or -99 dB will be reported for this value when outside the min/max operating
range.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.19 |
em870stateFlagOmiOffsetThe value of this object provides the state
of the RF Input Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.20 |
em870minValueOmiOffsetThe value of this object provides the minimum value
the RF Input Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.21 |
em870maxValueOmiOffsetThe value of this object provides the maximum value
the RF Input Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.22 |
em870alarmStateOmiOffsetThe value of this object provides the curent alarm state of
the RF Input Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.23 |
em870labelDFBPowerThe value of this object provides the label of the
DFB Output Power Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.24 |
em870uomDFBPowerThe value of this object provides the Unit of Measure of the
DFB Output Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.25 |
em870majorHighDFBPowerThe value of this object provides the Major High alarm value
of the DFB Output Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.26 |
em870majorLowDFBPowerThe value of this object provides the Major Low alarm value
of the DFB Output Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.27 |
em870minorHighDFBPowerThe value of this object provides the Minor High alarm value
of the DFB Output Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.28 |
em870minorLowDFBPowerThe value of this object provides the Minor Low alarm value
of the DFB Output Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.29 |
em870currentValueDFBPowerThe value of this object provides the Current value
of the DFB Output Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.30 |
em870stateFlagDFBPowerThe value of this object provides the state
of the DFB Output Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.31 |
em870minValueDFBPowerThe value of this object provides the minimum value
the DFB Output Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.32 |
em870maxValueDFBPowerThe value of this object provides the maximum value
the DFB Output Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.33 |
em870alarmStateDFBPowerThe value of this object provides the curent alarm state of
the DFB Output Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.34 |
em870labelLaserBiasThe value of this object provides the label of the
Laser Bias Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.35 |
em870uomLaserBiasThe value of this object provides the Unit of Measure of the
Laser Bias Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.36 |
em870majorHighLaserBiasThe value of this object provides the Major High alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.37 |
em870majorLowLaserBiasThe value of this object provides the Major Low alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.38 |
em870minorHighLaserBiasThe value of this object provides the Minor High alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.39 |
em870minorLowLaserBiasThe value of this object provides the Minor Low alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.40 |
em870currentValueLaserBiasThe value of this object provides the Current value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.41 |
em870stateFlagLaserBiasThe value of this object provides the state
of the Laser Bias Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.42 |
em870minValueLaserBiasThe value of this object provides the minimum value
the Laser Bias Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.43 |
em870maxValueLaserBiasThe value of this object provides the maximum value
the Laser Bias Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.44 |
em870alarmStateLaserBiasThe value of this object provides the curent alarm state of
the Laser Bias Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.45 |
em870labelCoolerCurrentThe value of this object provides the label of the
Cooler Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.46 |
em870uomCoolerCurrentThe value of this object provides the Unit of Measure of the
Cooler Current Analog parameter..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.47 |
em870majorHighCoolerCurrentThe value of this object provides the Major High alarm value
of the Cooler Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.48 |
em870majorLowCoolerCurrentThe value of this object provides the Major Low alarm value
of the Cooler Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.49 |
em870minorHighCoolerCurrentThe value of this object provides the Minor High alarm value
of the Cooler Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.50 |
em870minorLowCoolerCurrentThe value of this object provides the Minor Low alarm value
of the Cooler Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.51 |
em870currentValueCoolerCurrentThe value of this object provides the Current value
of the Cooler Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.52 |
em870stateFlagCoolerCurrentThe value of this object provides the state
of the Cooler Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.53 |
em870minValueCoolerCurrentThe value of this object provides the minimum value
the Cooler Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.54 |
em870maxValueCoolerCurrentThe value of this object provides the maximum value
the Cooler Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.55 |
em870alarmStateCoolerCurrentThe value of this object provides the curent alarm state of
the Cooler Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.56 |
em870labelLaserTempThe value of this object provides the label of the
Laser Temp Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.57 |
em870uomLaserTempThe value of this object provides the Unit of Measure of the
Laser Temp Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.58 |
em870majorHighLaserTempThe value of this object provides the Major High alarm value
of the Laser Temp Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.59 |
em870majorLowLaserTempThe value of this object provides the Major Low alarm value
of the Laser Temp Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.60 |
em870minorHighLaserTempThe value of this object provides the Minor High alarm value
of the Laser Temp Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.61 |
em870minorLowLaserTempThe value of this object provides the Minor Low alarm value
of the Laser Temp Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.62 |
em870currentValueLaserTempThe value of this object provides the Current value
of the Laser Temp Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.63 |
em870stateFlagLaserTempThe value of this object provides the state
of the Laser Temp Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.64 |
em870minValueLaserTempThe value of this object provides the minimum value
the Laser TempAnalog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.65 |
em870maxValueLaserTempThe value of this object provides the maximum value
the Laser Temp Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.66 |
em870alarmStateLaserTempThe value of this object provides the curent alarm state of
the Laser Temp Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.67 |
em870labelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.68 |
em870uomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.69 |
em870majorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.70 |
em870majorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.71 |
em870minorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.72 |
em870minorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.73 |
em870currentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.74 |
em870stateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.75 |
em870minValueModTempThe value of this object provides the minimum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.76 |
em870maxValueModTempThe value of this object provides the maximum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.77 |
em870alarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.78 |
em870labelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.79 |
em870uomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.80 |
em870majorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.81 |
em870majorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.82 |
em870minorHighFanCurrentThe value of this object provides the Minor High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.83 |
em870minorLowFanCurrentThe value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.84 |
em870currentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.85 |
em870stateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.86 |
em870minValueFanCurrentThe value of this object provides the minimum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.87 |
em870maxValueFanCurrentThe value of this object provides the maximum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.88 |
em870alarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.89 |
em870label12VoltThe value of this object provides the label of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.90 |
em870uom12VoltThe value of this object provides the Unit of Measure of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.2.1.91 |
em870majorHigh12VoltThe value of this object provides the Major High alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.92 |
em870majorLow12VoltThe value of this object provides the Major Low alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.93 |
em870minorHigh12VoltThe value of this object provides the Minor High alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.94 |
em870minorLow12VoltThe value of this object provides the Minor Low alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.95 |
em870currentValue12VoltThe value of this object provides the Current value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.96 |
em870stateFlag12VoltThe value of this object provides the state
of the 12v Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.97 |
em870minValue12VoltThe value of this object provides the minimum value
the 12v Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.98 |
em870maxValue12VoltThe value of this object provides the maximum value
the 12v Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.12.2.1.99 |
em870alarmState12VoltThe value of this object provides the curent alarm state of
the 12v Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.2.1.100 |
gx2Em870DigitalTableThis table contains gx2Em870 specific parameters with
nominal and current values. SEQUENCE OF Gx2Em870DigitalEntry .1.3.6.1.4.1.1166.6.1.2.12.3 |
gx2Em870DigitalEntryThis list contains the digital parameters and descriptions. Gx2Em870DigitalEntry .1.3.6.1.4.1.1166.6.1.2.12.3.4 |
gx2Em870DigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.3.4.1 |
em870labelOpticalAlarmSetpointThe value of this object provides the label of the
EM870's Optical Alarm setpoint Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.3.4.2 |
em870enumOpticalAlarmSetpointThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.3.4.3 |
em870valueOpticalAlarmSetpointThe value of this object is the current value of the parameter.
Note that reset setting returns the parameter to the off settingrw Enumeration .1.3.6.1.4.1.1166.6.1.2.12.3.4.4 |
em870stateFlagOpticalAlarmSetpointThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.3.4.5 |
gx2Em870StatusTableThis table contains gx2Em870 specific parameters with
nominal and current values. SEQUENCE OF Gx2Em870StatusEntry .1.3.6.1.4.1.1166.6.1.2.12.4 |
gx2Em870StatusEntryThis list contains Status parameters and descriptions. Gx2Em870StatusEntry .1.3.6.1.4.1.1166.6.1.2.12.4.2 |
gx2Em870StatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.4.2.1 |
em870labelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.4.2.2 |
em870valueBootThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.4.2.3 |
em870stateflagBootThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.4.2.4 |
em870labelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.4.2.5 |
em870valueFlashThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.4.2.6 |
em870stateflagFlashThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.4.2.7 |
em870labelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.4.2.8 |
em870valueFactoryDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.4.2.9 |
em870stateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.4.2.10 |
em870labelAlarmDataCrcThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.4.2.11 |
em870valueAlarmDataCrcThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.4.2.12 |
em870stateflagAlarmDataCrcThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.4.2.13 |
em870labelCsoStatusThe value of this object provides the label of the
CSO Status parameter. This parameter is always hiddenro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.4.2.14 |
em870valueCsoStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.4.2.15 |
em870stateflagCsoStatusThe value of this object provides the state
of the the CSO Status parameter. This parameter is always hidden
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.4.2.16 |
gx2Em870FactoryTableThis table contains gx2Em870 specific parameters with
nominal and current values. SEQUENCE OF Gx2Em870FactoryEntry .1.3.6.1.4.1.1166.6.1.2.12.5 |
gx2Em870FactoryEntryThis list contains Factory parameters and descriptions. Gx2Em870FactoryEntry .1.3.6.1.4.1.1166.6.1.2.12.5.3 |
gx2Em870FactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.5.3.1 |
em870bootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.5.3.2 |
em870bootStatusByteThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.5.3.3 |
em870bank1CRCThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.5.3.4 |
em870bank2CRCThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.5.3.5 |
em870prgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.5.3.6 |
em870factoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.5.3.7 |
em870calculateCRCThis object indicates which of the Emnums will have the CRC calculated.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.12.5.3.8 |
em870hourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.5.3.9 |
em870flashPrgCntAThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.5.3.10 |
em870flashPrgCntBThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.5.3.11 |
em870flashBankARevThis object provides the revision of flash bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.5.3.12 |
em870flashBankBRevThis object provides the revision of flash bank 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.12.5.3.13 |
gx2Em870HoldTimeTableThis table contains gx2EM870 specific parameters with
nominal and current values. SEQUENCE OF Gx2Em870HoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.12.6 |
gx2Em870HoldTimeEntryThis list contains digital product class and the
associated RF channel parameters and descriptions. Gx2Em870HoldTimeEntry .1.3.6.1.4.1.1166.6.1.2.12.6.5 |
gx2Em870HoldTimeTableIndexThe value of this object is the index of the data object.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.6.5.1 |
gx2Em870HoldTimeSpecIndexThe value of this object identifies the index of the alarm object to be modified.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.12.6.5.2 |
gx2Em870HoldTimeDataThe value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds.rw INTEGER .1.3.6.1.4.1.1166.6.1.2.12.6.5.3 |