OMNI-gx2EA1000-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for OMNI-gx2EA1000-MIB.
209
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
209 total| Object Name |
|---|
trapEA1000ConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.1 |
trapEA1000ConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.2 |
trapEA1000RFInputAlarmThis trap is issued when the Laser Modules RF input parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.3 |
trapEA1000RFOverloadAlarmThis trap is issued when the Laser Modules RF overload parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.4 |
trapEA1000RFOffsetAlarmThis trap is issued when the Laser Modules RF Offset parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.5 |
trapEA1000OpticalPowerAlarmThis trap is issued when the Laser Modules Optical Power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.6 |
trapEA1000LaserBiasAlarmThis trap is issued when the Laser Bias parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.7 |
trapEA1000LaserTempAlarmThis trap is issued when the Laser Temperature parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.8 |
trapEA1000TECCurrentAlarmThis trap is issued when the Laser Modules TEC Current parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.9 |
trapEA1000Fan1SpeedAlarmThis trap is issued when the Laser Modules Fan 1 Speed
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.10 |
trapEA1000Fan2SpeedAlarmThis trap is issued when the Laser Modules Fan 2 Speed
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.11 |
trapEA100012vAlarmThis trap is issued when the Laser Modules 12 Volt parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.12 |
trapEA1000ModuleTempAlarmThis trap is issued when the Laser Module Temperature goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.13 |
trapEA1000FlashAlarmThis trap is issued when the Laser Modules detects an error during
Flash memory operations. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.14 |
trapEA1000LaserBiasCntLoopAlarmThis trap is issued when the Laser Modules detects an error in its Laser Bias control loop
operation. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.15 |
trapEA1000BankBootAlarmThis trap is issued when the Laser Modules detects an error while booting
from bank 0 or bank 1. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.16 |
trapEA1000LaserBiasCntLoopInitAlarmThis trap is issued when the Laser Bias Control loop init fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.17 |
trapEA1000RFParamInitAlarmThis trap is issued when the RF parameter Init fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.18 |
trapEA1000TECParamInitAlarmThis trap is issued when the TEC Parameter Init fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.19 |
trapEA1000AttnTableInitAlarmThis trap is issued when the Attenuator Table Init fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.20 |
trapEA1000PowerMeterTableInitAlarmThis trap is issued when the Power Meter Table Init fails. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.21 |
trapEA1000LaserDataCRCAlarmThis trap is issued when the Laser Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.22 |
trapEA1000AlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.23 |
trapEA1000FactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.24 |
trapEA1000UserRFOffAlarmThis trap is issued when the the User RF is turned off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.25 |
trapEA1000UserOpticalOffAlarmThis trap is issued when the User Optical Power is turned off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.26 |
trapEA1000ResetFactoryDefaultAlarmThis trap is issued when the Factory Default Reset occurs. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.33.0.27 |
gx2ea1000Descriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.33.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.33.1 |
gx2ea1000AnalogTableThis table contains gx2Ea1000 specific parameters with
nominal and current values. SEQUENCE OF Gx2ea1000AnalogEntry .1.3.6.1.4.1.1166.6.1.2.33.2 |
gx2ea1000AnalogEntryThis list contains the analog parameters and descriptions. Gx2ea1000AnalogEntry .1.3.6.1.4.1.1166.6.1.2.33.2.1 |
gx2ea1000AnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.2.1.1 |
ea1000labelOffsetNomMonitorThe value of this object provides the label of the
Offset Monitor Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.2 |
ea1000uomOffsetNomMonitorThe value of this object provides the Unit of Measure of the
Offset Monitor Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.3 |
ea1000majorHighOffsetNomMonitorThe value of this object provides the Major High alarm value
of the Offset Monitor Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.4 |
ea1000majorLowOffsetNomMonitorThe value of this object provides the Major Low alarm value
of the Offset Monitor Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.5 |
ea1000minorHighOffsetNomMonitorThe value of this object provides the Minor High alarm value
of the Offset Monitor Analog parameter.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.6 |
ea1000minorLowOffsetNomMonitorThe value of this object provides the Minor Low alarm value
of the Offset Monitor Analog parameter.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.7 |
ea1000currentValueOffsetNomMonitorThe value of this object provides the Current value
of the Offset Monitor Analog parameter.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.8 |
ea1000stateFlagOffsetNomMonitorThe value of this object provides the state
of the Offset Monitor Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable)ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.9 |
ea1000minValueOffsetNomMonitorThe value of this object provides the minimum value
the Offset Monitor Analog parameter can achive.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.10 |
ea1000maxValueOffsetNomMonitorThe value of this object provides the maximum value
the Offset Monitor Analog parameter can achive.
This value is a float and is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.11 |
ea1000alarmStateOffsetNomMonitorThe value of this object provides the curent alarm state of
the Offset Monitor Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.12 |
ea1000labelOffsetNomCntThe value of this object provides the label of the
Offset Control Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.13 |
ea1000uomOffsetNomCntThe value of this object provides the label of the
Offset Control Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.14 |
ea1000majorHighOffsetNomCntThe value of this object provides the Major High alarm value
of the Offset Control Analog parameter.
This value is a float and is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.15 |
ea1000majorLowOffsetNomCntThe value of this object provides the Major Low alarm value
of the Offset Control Analog parameter.
This value is a float and is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.16 |
ea1000minorHighOffsetNomCntThe value of this object provides the Minor High alarm value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.17 |
ea1000minorLowOffsetNomCntThe value of this object provides the Minor Low alarm value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.18 |
ea1000currentValueOffsetNomCntThe value of this object provides the Current value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.19 |
ea1000stateFlagOffsetNomCntThe value of this object provides the state
of the Offset Control Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable)ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.20 |
ea1000minValueOffsetNomCntThe value of this object provides the minimum value
the Offset Control Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.21 |
ea1000maxValueOffsetNomCntThe value of this object provides the maximum value
the Offset Control Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.22 |
ea1000alarmStateOffsetNomCntThe value of this object provides the curent alarm state of
the Offset Control Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.23 |
ea1000labelOptPowerThe value of this object provides the label of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.24 |
ea1000uomOptPowerThe value of this object provides the Unit of Measure of the
Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.25 |
ea1000majorHighOptPowerThe value of this object provides the Major High alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.26 |
ea1000majorLowOptPowerThe value of this object provides the Major Low alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.27 |
ea1000minorHighOptPowerThe value of this object provides the Minor High alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.28 |
ea1000minorLowOptPowerThe value of this object provides the Minor Low alarm value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.29 |
ea1000currentValueOptPowerThe value of this object provides the Current value
of the Optical Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.30 |
ea1000stateFlagOptPowerThe value of this object provides the state
of the Optical Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.31 |
ea1000minValueOptPowerThe value of this object provides the minimum value
the Optical Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.32 |
ea1000maxValueOptPowerThe value of this object provides the maximum value
the Optical Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.33 |
ea1000alarmStateOptPowerThe value of this object provides the curent alarm state of
the Optical Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.34 |
ea1000labelLaserTempThe value of this object provides the label of the
Laser Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.35 |
ea1000uomLaserTempThe value of this object provides the Unit of Measure of the
Laser Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.36 |
ea1000majorHighLaserTempThe value of this object provides the Major High alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.37 |
ea1000majorLowLaserTempThe value of this object provides the Major Low alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.38 |
ea1000minorHighLaserTempThe value of this object provides the Minor High alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.39 |
ea1000minorLowLaserTempThe value of this object provides the Minor Low alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.40 |
ea1000currentValueLaserTempThe value of this object provides the Current value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.41 |
ea1000stateFlagLaserTempThe value of this object provides the state
of the Laser Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.42 |
ea1000minValueLaserTempThe value of this object provides the minimum value
the Laser Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.43 |
ea1000maxValueLaserTempThe value of this object provides the maximum value
the Laser Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.44 |
ea1000alarmStateLaserTempThe value of this object provides the curent alarm state of
the Laser Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.45 |
ea1000labelLaserBiasThe value of this object provides the label of the
Laser Bias Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.46 |
ea1000uomLaserBiasThe value of this object provides the Unit of Measure of the
Laser Bias Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.47 |
ea1000majorHighLaserBiasThe value of this object provides the Major High alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.48 |
ea1000majorLowLaserBiasThe value of this object provides the Major Low alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.49 |
ea1000minorHighLaserBiasThe value of this object provides the Minor High alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.50 |
ea1000minorLowLaserBiasThe value of this object provides the Minor Low alarm value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.51 |
ea1000currentValueLaserBiasThe value of this object provides the Current value
of the Laser Bias Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.52 |
ea1000stateFlagLaserBiasThe value of this object provides the state
of the Laser Bias Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.53 |
ea1000minValueLaserBiasThe value of this object provides the minimum value
the Laser Bias Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.54 |
ea1000maxValueLaserBiasThe value of this object provides the maximum value
the Laser Bias Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.55 |
ea1000alarmStateLaserBiasThe value of this object provides the curent alarm state of
the Laser Bias Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.56 |
ea1000labelTecCurrentThe value of this object provides the label of the
TEC Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.57 |
ea1000uomTecCurrentThe value of this object provides the Unit of Measure of the
TEC Current Analog parameter..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.58 |
ea1000majorHighTecCurrentThe value of this object provides the Major High alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.59 |
ea1000majorLowTecCurrentThe value of this object provides the Major Low alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.60 |
ea1000minorHighTecCurrentThe value of this object provides the Minor High alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.61 |
ea1000minorLowTecCurrentThe value of this object provides the Minor Low alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.62 |
ea1000currentValueTecCurrentThe value of this object provides the Current value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.63 |
ea1000stateFlagTecCurrentThe value of this object provides the state
of the TEC Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.64 |
ea1000minValueTecCurrentThe value of this object provides the minimum value
the TEC Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.65 |
ea1000maxValueTecCurrentThe value of this object provides the maximum value
the TEC Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.66 |
ea1000alarmStateTecCurrentThe value of this object provides the curent alarm state of
the TEC Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.67 |
ea1000labelModuleTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.68 |
ea1000uomModuleTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.69 |
ea1000majorHighModuleTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.70 |
ea1000majorLowModuleTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.71 |
ea1000minorHighModuleTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.72 |
ea1000minorLowModuleTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.73 |
ea1000currentValueModuleTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.74 |
ea1000stateFlagModuleTempThe value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.75 |
ea1000minValueModuleTempThe value of this object provides the minimum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.76 |
ea1000maxValueModuleTempThe value of this object provides the maximum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.77 |
ea1000alarmStateModuleTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.78 |
ea1000labelFan1SpeedThe value of this object provides the label of the
Fan 1 Speed Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.79 |
ea1000uomFan1SpeedThe value of this object provides the Unit of Measure of the
Fan 1 Speed Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.80 |
ea1000majorHighFan1SpeedThe value of this object provides the Major High alarm value
of the Fan 1 Speed Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.81 |
ea1000majorLowFan1SpeedThe value of this object provides the Major Low alarm value
of the Fan 1 Speed Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.82 |
ea1000minorHighFan1SpeedThe value of this object provides the Minor High alarm value
of the Fan 1 Speed Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.83 |
ea1000minorLowFan1SpeedThe value of this object provides the Minor Low alarm value
of the Fan 1 Speed Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.84 |
ea1000currentValueFan1SpeedThe value of this object provides the Current value
of the Fan 1 Speed Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.85 |
ea1000stateFlagFan1SpeedThe value of this object provides the state
of the Fan 1 Speed Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.86 |
ea1000minValueFan1SpeedThe value of this object provides the minimum value
the Fan 1 Speed Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.87 |
ea1000maxValueFan1SpeedThe value of this object provides the maximum value
the Fan 1 Speed Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.88 |
ea1000alarmStateFan1SpeedThe value of this object provides the curent alarm state of
the Fan 1 Speed Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.89 |
ea1000labelFan2SpeedThe value of this object provides the label of the
Fan 2 Speed Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.90 |
ea1000uomFan2SpeedThe value of this object provides the Unit of Measure of the
Fan 2 Speed Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.91 |
ea1000majorHighFan2SpeedThe value of this object provides the Major High alarm value
of the Fan 2 Speed Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.92 |
ea1000majorLowFan2SpeedThe value of this object provides the Major Low alarm value
of the Fan 2 Speed Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.93 |
ea1000minorHighFan2SpeedThe value of this object provides the Minor High alarm value
of the Fan 2 Speed Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.
In this version of the Firmware and MIB this Parameter is not used and is
optional. All reads will return the Unused Parameter (10,000,000)ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.94 |
ea1000minorLowFan2SpeedThe value of this object provides the Minor Low alarm value
of the Fan 2 Speed Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.95 |
ea1000currentValueFan2SpeedThe value of this object provides the Current value
of the Fan 2 Speed Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.96 |
ea1000stateFlagFan2SpeedThe value of this object provides the state
of the Fan 2 Speed Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.97 |
ea1000minValueFan2SpeedThe value of this object provides the minimum value
the Fan 2 Speed Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.98 |
ea1000maxValueFan2SpeedThe value of this object provides the maximum value
the Fan 2 Speed Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.99 |
ea1000alarmStateFan2SpeedThe value of this object provides the curent alarm state of
the Fan 2 Speed Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.100 |
ea1000label12VoltThe value of this object provides the label of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.101 |
ea1000uom12VoltThe value of this object provides the Unit of Measure of the
12v Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.2.1.102 |
ea1000majorHigh12VoltThe value of this object provides the Major High alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.103 |
ea1000majorLow12VoltThe value of this object provides the Major Low alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.104 |
ea1000minorHigh12VoltThe value of this object provides the Minor High alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.105 |
ea1000minorLow12VoltThe value of this object provides the Minor Low alarm value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.106 |
ea1000currentValue12VoltThe value of this object provides the Current value
of the 12v Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.107 |
ea1000stateFlag12VoltThe value of this object provides the state
of the 12v Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.108 |
ea1000minValue12VoltThe value of this object provides the minimum value
the 12v Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.109 |
ea1000maxValue12VoltThe value of this object provides the maximum value
the 12v Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.33.2.1.110 |
ea1000alarmState12VoltThe value of this object provides the curent alarm state of
the 12v Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.2.1.111 |
gx2ea1000DigitalTableThis table contains gx2Ea1000 specific parameters with
nominal and current values. SEQUENCE OF Gx2ea1000DigitalEntry .1.3.6.1.4.1.1166.6.1.2.33.3 |
gx2ea1000DigitalEntryThis list contains digital parameters and descriptions. Gx2ea1000DigitalEntry .1.3.6.1.4.1.1166.6.1.2.33.3.2 |
gx2ea1000DigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.3.2.1 |
ea1000labelRfInputThe value of this object provides the label of the
RF Input Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.2 |
ea1000enumRfInputThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.3 |
ea1000valueRfInputThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.4 |
ea1000stateflagRfInputThe value of this object provides the state
of the RF Input Control Digital parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.5 |
ea1000labelOptOutputThe value of this object provides the label of the
Optical Output Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.6 |
ea1000enumOptOutputThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.7 |
ea1000valueOptOutputThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.8 |
ea1000stateflagOptOutputThe value of this object provides the ea1000state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.9 |
ea1000labelLaserModeThe value of this object provides the label of the
Laser Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.10 |
ea1000enumLaserModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.11 |
ea1000valueLaserModeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.12 |
ea1000stateflagLaserModeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.13 |
ea1000labelAttenSettingThe value of this object provides the label of the
Attenuation Setting Ditital Parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.14 |
ea1000enumAttenSettingThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.15 |
ea1000valueAttenSettingThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.16 |
ea1000stateflagAttenSettingThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.17 |
ea1000labelLaserSecModeThe value of this object provides the label of the
Laser Secondary Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.18 |
ea1000enumLaserSecModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.19 |
ea1000valueLaserSecModeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.20 |
ea1000stateflagLaserSecModeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.21 |
ea1000labelVideoOffsetThe value of this object provides the label of the
Video Offset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.22 |
ea1000enumVideoOffsetThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.23 |
ea1000valueVideoOffsetThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.24 |
ea1000stateflagVideoOffsetThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.25 |
ea1000labelFactoryDefaultThe value of this object provides the label of the
Factory Default Reset Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.26 |
ea1000enumFactoryDefaultThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.3.2.27 |
ea1000valueFactoryDefaultThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.28 |
ea1000stateflagFactoryDefaultThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.3.2.29 |
gx2ea1000StatusTableThis table contains gx2Ea1000 specific parameters with
nominal and current values. SEQUENCE OF Gx2ea1000StatusEntry .1.3.6.1.4.1.1166.6.1.2.33.4 |
gx2ea1000StatusEntryThis list contains Status parameters and descriptions. Gx2ea1000StatusEntry .1.3.6.1.4.1.1166.6.1.2.33.4.3 |
gx2ea1000StatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.4.3.1 |
ea1000labelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.4.3.2 |
ea1000valueBootThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.3 |
ea1000stateflagBootThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.4 |
ea1000labelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.4.3.5 |
ea1000valueFlashThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.6 |
ea1000stateflagFlashThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.7 |
ea1000labelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.4.3.8 |
ea1000valueFactoryDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.9 |
ea1000stateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.10 |
ea1000labelLaserDataCRCThe value of this object provides the label of the
Laser Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.4.3.11 |
ea1000valueLaserDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.12 |
ea1000stateflagLaserDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.13 |
ea1000labelAlarmDataCrcThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.4.3.14 |
ea1000valueAlarmDataCrcThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.15 |
ea1000stateflagAlarmDataCrcThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.16 |
ea1000labelRFInputStatusThe value of this object provides the label of the
RF Input Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.4.3.17 |
ea1000valueRFInputStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.18 |
ea1000stateflagRFInputStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.4.3.19 |
gx2ea1000FactoryTableThis table contains gx2Ea1000 specific parameters with
nominal and current values. SEQUENCE OF Gx2ea1000FactoryEntry .1.3.6.1.4.1.1166.6.1.2.33.5 |
gx2ea1000FactoryEntryThis list contains Factory parameters and descriptions. Gx2ea1000FactoryEntry .1.3.6.1.4.1.1166.6.1.2.33.5.4 |
gx2ea1000FactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.5.4.1 |
ea1000bootControlByteValueThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.5.4.2 |
ea1000bootStatusByteValueThis object indicates the status of the last bootro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.5.4.3 |
ea1000bank1CRCValueThis object provides the CRC code of bank 0.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.5.4.4 |
ea1000bank2CRCValueThis object provides the CRC code of bank 1.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.5.4.5 |
ea1000prgEEPROMByteValueThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.5.4.6 |
ea1000factoryCRCValueThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.5.4.7 |
ea1000calculateCRCValueThis object indicates which of the Emnums will have the CRC calculated.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.33.5.4.8 |
ea1000hourMeterValueThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.5.4.9 |
ea1000flashPrgCntAValueThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.5.4.10 |
ea1000flashPrgCntBValueThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.33.5.4.11 |
ea1000flashBankARevValueThis object provides the revision of flash bank 0.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.5.4.12 |
ea1000flashBankBRevValueThis object provides the revision of flash bank 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.33.5.4.13 |