OMNI-gx2Dm870-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
183
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
183 total| Object Name |
|---|
trapDM870ConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.1 |
trapDM870ConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.2 |
trapDM870fanCurrentAlarmThis trap is issued when the Fan Current
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.3 |
trapDM870ModuleTempAlarmThis trap is issued when the Module Temperature parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.4 |
trapDM870omiOffsetAlarmThis trap is issued when the OMI Offset goes out of range. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.5 |
trapDM870tecCurrentAlarmThis trap is issued when the TEC Current parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.6 |
trapDM870LaserCurrentAlarmThis trap is issued when the Laser Current parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.7 |
trapDM870LaserTempAlarmThis trap is issued when the Laser Temp parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.8 |
trapDM870LaserPowerAlarmThis trap is issued when the Laser Power parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.9 |
trapDM870FlashAlarmThis trap is issued when the Laser Modules detects an error during
Flash memory operations. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.10 |
trapDM870BankBootAlarmThis trap is issued when the Laser Modules detects an error while booting
from bank 0 or bank 1. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.11 |
trapDM870AlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.12 |
trapDM870FactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.13 |
trapDM870CalDataCRCAlarmThis trap is issued when the Cal Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.14 |
trapDM870ResetFacDefaultThis trap is issued when the DM870 resets to factory defaults TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.15 |
trapDM870UserRFOffAlarmThis trap is issued when the the User RF is turned off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.16 |
trapDM870UserOpticalOffAlarmThis trap is issued when the User Optical Power is turned off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.17 |
trapDM870UserSBSOffAlarmThis trap is issued when the User SBS is turned off. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.18 |
trapDM870RFInputAlarmThis trap is issued when the Laser Modules RF input parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.19 |
trapDM870RFOverloadAlarmThis trap is issued when the Laser Modules RF overload parameter
goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.16.0.20 |
gx2Dm870Descriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.16.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.16.1 |
gx2Dm870AnalogTableThis table contains gx2Dm870 specific parameters with
nominal and current values. SEQUENCE OF Gx2Dm870AnalogEntry .1.3.6.1.4.1.1166.6.1.2.16.2 |
gx2Dm870AnalogEntryThis list contains the analog parameters and descriptions. Gx2Dm870AnalogEntry .1.3.6.1.4.1.1166.6.1.2.16.2.1 |
gx2Dm870AnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.2.1.1 |
dm870labelOffsetNomMonitorThe value of this object provides the label of the
Offset Monitor Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.2 |
dm870uomOffsetNomMonitorThe value of this object provides the Unit of Measure of the
Offset Monitor Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.3 |
dm870majorHighOffsetNomMonitorThe value of this object provides the Major High alarm value
of the Offset Monitor Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.4 |
dm870majorLowOffsetNomMonitorThe value of this object provides the Major Low alarm value
of the Offset Monitor Power Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.5 |
dm870minorHighOffsetNomMonitorThe value of this object provides the Minor High alarm value
of the Offset Monitor Power Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.6 |
dm870minorLowOffsetNomMonitorThe value of this object provides the Minor Low alarm value
of the Offset Monitor Power Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.7 |
dm870currentValueOffsetNomMonitorThe value of this object provides the Current value
of the Offset Monitor Power Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.8 |
dm870stateFlagOffsetNomMonitorThe value of this object provides the state
of the Offset Monitor Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.9 |
dm870minValueOffsetNomMonitorThe value of this object provides the minimum value
the Offset Monitor Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.10 |
dm870maxValueOffsetNomMonitorThe value of this object provides the maximum value
the Offset Monitor Power Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.11 |
dm870alarmStateOffsetNomMonitorThe value of this object provides the curent alarm state of
the Offset Monitor Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.12 |
dm870labelOffsetNomCntThe value of this object provides the label of the
Offset Control Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.13 |
dm870uomOffsetNomCntThe value of this object provides the Unit of Measure of the
Offset Control Analog parameter..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.14 |
dm870majorHighOffsetNomCntThe value of this object provides the Major High alarm value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.15 |
dm870majorLowOffsetNomCntThe value of this object provides the Major Low alarm value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.16 |
dm870minorHighOffsetNomCntThe value of this object provides the Minor High alarm value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.17 |
dm870minorLowOffsetNomCntThe value of this object provides the Minor Low alarm value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.18 |
dm870currentValueOffsetNomCntThe value of this object provides the Current value
of the Offset Control Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.19 |
dm870stateFlagOffsetNomCntThe value of this object provides the state
of the Offset Control Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.20 |
dm870minValueOffsetNomCntThe value of this object provides the minimum value
the Offset Control Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.21 |
dm870maxValueOffsetNomCntThe value of this object provides the maximum value
the Offset Control Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.22 |
dm870alarmStateOffsetNomCntThe value of this object provides the curent alarm state of
the Offset Control Analog parameter.roobsolete Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.23 |
dm870labelAttenSettingThe value of this object provides the label of the
Attenuator Setting Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.24 |
dm870uomAttenSettingThe value of this object provides the Unit of Measure of the
Attenuator Setting Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.25 |
dm870majorHighAttenSettingThe value of this object provides the Major High alarm value
of the Attenuator Setting Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.26 |
dm870majorLowAttenSettingThe value of this object provides the Major Low alarm value
of the Attenuator Setting Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.27 |
dm870minorHighAttenSettingThe value of this object provides the Minor High alarm value
of the Attenuator Setting Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.28 |
dm870minorLowAttenSettingThe value of this object provides the Minor Low alarm value
of the Attenuator Setting Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.29 |
dm870currentValueAttenSettingThe value of this object provides the Current value
of the Attenuator Setting Analog parameter.
This value is a floating point number that is represented as an
IEEE 32 bit number.rw Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.30 |
dm870stateFlagAttenSettingThe value of this object provides the state
of the Attenuator Setting Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.31 |
dm870minValueAttenSettingThe value of this object provides the minimum value
the Attenuator Setting Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.32 |
dm870maxValueAttenSettingThe value of this object provides the maximum value
the Attenuator Setting Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.33 |
dm870alarmStateAttenSettingThe value of this object provides the curent alarm state of
the Attenuator Setting Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.34 |
dm870labelLaserPowerThe value of this object provides the label of the
Laser Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.35 |
dm870uomLaserPowerThe value of this object provides the Unit of Measure of the
Laser Optical Power Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.36 |
dm870majorHighLaserPowerThe value of this object provides the Major High alarm value
of the Laser Optical Power Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.37 |
dm870majorLowLaserPowerThe value of this object provides the Major Low alarm value
of the Laser Optical Power Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.38 |
dm870minorHighLaserPowerThe value of this object provides the Minor High alarm value
of the Laser Optical Power Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.39 |
dm870minorLowLaserPowerThe value of this object provides the Minor Low alarm value
of the Laser Optical Power Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.40 |
dm870currentValueLaserPowerThe value of this object provides the Current value
of the Laser Optical Power Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.41 |
dm870stateFlagLaserPowerThe value of this object provides the state
of the Laser Optical Power Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.42 |
dm870minValueLaserPowerThe value of this object provides the minimum value
the Laser Optical Power Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.43 |
dm870maxValueLaserPowerThe value of this object provides the maximum value
the Laser Optical Power Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.44 |
dm870alarmStateLaserPowerThe value of this object provides the curent alarm state of
the Laser Optical Power Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.45 |
dm870labelLaserTempThe value of this object provides the label of the
Laser Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.46 |
dm870uomLaserTempThe value of this object provides the Unit of Measure of the
Laser Temperature Analog parameter..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.47 |
dm870majorHighLaserTempThe value of this object provides the Major High alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.48 |
dm870majorLowLaserTempThe value of this object provides the Major Low alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.49 |
dm870minorHighLaserTempThe value of this object provides the Minor High alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.50 |
dm870minorLowLaserTempThe value of this object provides the Minor Low alarm value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.51 |
dm870currentValueLaserTempThe value of this object provides the Current value
of the Laser Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.52 |
dm870stateFlagLaserTempThe value of this object provides the state
of the Laser Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.53 |
dm870minValueLaserTempThe value of this object provides the minimum value
the Laser Temperature Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.54 |
dm870maxValueLaserTempThe value of this object provides the maximum value
the Laser Temperature Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.55 |
dm870alarmStateLaserTempThe value of this object provides the curent alarm state of
the Laser Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.56 |
dm870labelLaserCurrentThe value of this object provides the label of the
Laser Bias Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.57 |
dm870uomLaserCurrentThe value of this object provides the Unit of Measure of the
Laser Bias Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.58 |
dm870majorHighLaserCurrentThe value of this object provides the Major High alarm value
of the Laser Bias Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.59 |
dm870majorLowLaserCurrentThe value of this object provides the Major Low alarm value
of the Laser Bias Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.60 |
dm870minorHighLaserCurrentThe value of this object provides the Minor High alarm value
of the Laser Bias Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.61 |
dm870minorLowLaserCurrentThe value of this object provides the Minor Low alarm value
of the Laser Bias Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.62 |
dm870currentValueLaserCurrentThe value of this object provides the Current value
of the Laser Bias Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.63 |
dm870stateFlagLaserCurrentThe value of this object provides the state
of the Laser Bias Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.64 |
dm870minValueLaserCurrentThe value of this object provides the minimum value
the Laser Bias Current Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.65 |
dm870maxValueLaserCurrentThe value of this object provides the maximum value
the Laser Bias Current Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.66 |
dm870alarmStateLaserCurrentThe value of this object provides the curent alarm state of
the Laser Bias Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.67 |
dm870labelTecCurrentThe value of this object provides the label of the
TEC Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.68 |
dm870uomTecCurrentThe value of this object provides the Unit of Measure of the
TEC Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.69 |
dm870majorHighTecCurrentThe value of this object provides the Major High alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.70 |
dm870majorLowTecCurrentThe value of this object provides the Major Low alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.71 |
dm870minorHighTecCurrentThe value of this object provides the Minor High alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.72 |
dm870minorLowTecCurrentThe value of this object provides the Minor Low alarm value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.73 |
dm870currentValueTecCurrentThe value of this object provides the Current value
of the TEC Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.74 |
dm870stateFlagTecCurrentThe value of this object provides the state
of the TEC Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.75 |
dm870minValueTecCurrentThe value of this object provides the minimum value
the TEC Current Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.76 |
dm870maxValueTecCurrentThe value of this object provides the maximum value
the TEC Current Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.77 |
dm870alarmStateTecCurrentThe value of this object provides the curent alarm state of
the TEC Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.78 |
dm870labelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.79 |
dm870uomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.80 |
dm870majorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.81 |
dm870majorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.82 |
dm870minorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.83 |
dm870minorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.84 |
dm870currentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.85 |
dm870stateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.86 |
dm870minValueModTempThe value of this object provides the minimum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.87 |
dm870maxValueModTempThe value of this object provides the maximum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.88 |
dm870alarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.89 |
dm870labelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.90 |
dm870uomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.2.1.91 |
dm870majorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.92 |
dm870majorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.93 |
dm870minorHighFanCurrentThe value of this object provides the Minor High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.94 |
dm870minorLowFanCurrentThe value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.95 |
dm870currentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.96 |
dm870stateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.97 |
dm870minValueFanCurrentThe value of this object provides the minimum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.98 |
dm870maxValueFanCurrentThe value of this object provides the maximum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.16.2.1.99 |
dm870alarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.2.1.100 |
gx2Dm870DigitalTableThis table contains gx2Dm870m specific parameters with
nominal and current values. SEQUENCE OF Gx2Dm870DigitalEntry .1.3.6.1.4.1.1166.6.1.2.16.3 |
gx2Dm870DigitalEntryThis list contains digital parameters and descriptions. Gx2Dm870DigitalEntry .1.3.6.1.4.1.1166.6.1.2.16.3.2 |
gx2Dm870DigitalTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.3.2.1 |
dm870labelRfInputThe value of this object provides the label of the
RF Input Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.3.2.2 |
dm870enumRfInputThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.3.2.3 |
dm870valueRfInputThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.16.3.2.4 |
dm870stateflagRfInputThe value of this object provides the state
of the RF Input Control Digital parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.3.2.5 |
dm870labelOptOutputThe value of this object provides the label of the
Optical Output Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.3.2.6 |
dm870enumOptOutputThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.3.2.7 |
dm870valueOptOutputThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.16.3.2.8 |
dm870stateflagOptOutputThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.3.2.9 |
dm870labelSbsControlThe value of this object provides the label of the
SBS Control Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.3.2.10 |
dm870enumSbsControlThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.3.2.11 |
dm870valueSbsControlThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.16.3.2.12 |
dm870stateflagSbsControlThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.3.2.13 |
dm870labelLaserModeThe value of this object provides the label of the
Laser Mode Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.3.2.14 |
dm870enumLaserModeThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.3.2.15 |
dm870valueLaserModeThe value of this object is the current value of the parameter.rw Enumeration .1.3.6.1.4.1.1166.6.1.2.16.3.2.16 |
dm870stateflagLaserModeThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.3.2.17 |
dm870labelFactoryDefaultThe value of this object provides the label of the
Factory Default Digital parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.3.2.18 |
dm870enumFactoryDefaultThe value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value
of 1..ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.3.2.19 |
dm870valueFactoryDefaultThe value of this object is the current value of the parameter.
Return value is meaninglessrw Enumeration .1.3.6.1.4.1.1166.6.1.2.16.3.2.20 |
dm870stateflagFactoryDefaultThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.3.2.21 |
gx2Dm870StatusTableThis table contains gx2Dm870 specific parameters with
nominal and current values. SEQUENCE OF Gx2Dm870StatusEntry .1.3.6.1.4.1.1166.6.1.2.16.4 |
gx2Dm870StatusEntryThis list contains Status parameters and descriptions. Gx2Dm870StatusEntry .1.3.6.1.4.1.1166.6.1.2.16.4.3 |
gx2Dm870StatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.4.3.1 |
dm870labelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.4.3.2 |
dm870valueBootThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.3 |
dm870stateflagBootThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.4 |
dm870labelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.4.3.5 |
dm870valueFlashThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.6 |
dm870stateflagFlashThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.7 |
dm870labelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.4.3.8 |
dm870valueFactoryDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.9 |
dm870stateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.10 |
dm870labelLaserDataCRCThe value of this object provides the label of the
Laser Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.4.3.11 |
dm870valueLaserDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.12 |
dm870stateflagLaserDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.13 |
dm870labelAlarmDataCrcThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.4.3.14 |
dm870valueAlarmDataCrcThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.15 |
dm870stateflagAlarmDataCrcThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.16 |
dm870labelRFInputStatusThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.4.3.17 |
dm870valueRFInputStatusThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.18 |
dm870stateflagRFInputStatusThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.16.4.3.19 |
gx2Dm870FactoryTableThis table contains gx2Dm870 specific parameters with
nominal and current values. SEQUENCE OF Gx2Dm870FactoryEntry .1.3.6.1.4.1.1166.6.1.2.16.5 |
gx2Dm870FactoryEntryThis list contains Factory parameters and descriptions. Gx2Dm870FactoryEntry .1.3.6.1.4.1.1166.6.1.2.16.5.4 |
gx2Dm870FactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.5.4.1 |
dm870bootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.5.4.2 |
dm870bootStatusByteThis object indicates the status of the last boot. Bit 2 =
Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail
and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail)ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.5.4.3 |
dm870bank1CRCThis object provides the CRC code of bank 0. The display
formate for the data is Hex.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.5.4.4 |
dm870bank2CRCThis object provides the CRC code of bank 1.The display
formate for the data is Hex.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.5.4.5 |
dm870prgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.5.4.6 |
dm870factoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.5.4.7 |
dm870calculateCRCThis object indicates which of the Enums will have the CRC
calculated.roobsolete Enumeration .1.3.6.1.4.1.1166.6.1.2.16.5.4.8 |
dm870hourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.5.4.9 |
dm870flashPrgCntAThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.5.4.10 |
dm870flashPrgCntBThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.16.5.4.11 |
dm870flashBankARevThis object provides the revision of flash bank 0. The rev is
2 characters.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.16.5.4.12 |
dm870flashBankBRevThis object provides the revision of flash bank 1. The rev is