OMNI-gx2CEB-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
120
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
120 total| Object Name |
|---|
trapCEBConfigChangeIntegerThis trap is issued if configuration of a single variable
with integer type was changed (via ANY interface).
TrapChangedValueInteger variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.20.0.1 |
trapCEBConfigChangeDisplayStringThis trap is issued if configuration of a single variable
with DispalayString type was changed (via ANY interface).
TrapChangedValueDisplayString variable may contain current reading
of that variable.
trapPerceivedSeverity - 'indeterminate' TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.20.0.2 |
trapCEBfanCurrentAlarmThis trap is issued when the Fan Current
parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.20.0.3 |
trapCEBModuleTempAlarmThis trap is issued when the Module Temperature parameter goes out of range.
trapAdditionalInfoInteger variable contains current reading of
the this parameter. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.20.0.4 |
trapCEBFlashAlarmThis trap is issued when the Laser Modules detects an error during
Flash memory operations. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.20.0.5 |
trapCEBBankBootAlarmThis trap is issued when the Laser Modules detects an error while booting
from bank 0 or bank 1. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.20.0.6 |
trapCEBAlarmDataCRCAlarmThis trap is issued when the Alarm Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.20.0.7 |
trapCEBFactoryDataCRCAlarmThis trap is issued when the Factory Data CRC is incorrect. TRAP-TYPE .1.3.6.1.4.1.1166.6.1.2.20.0.8 |
gx2CEBDescriptor OBJECT IDENTIFIER .1.3.6.1.4.1.1166.6.1.2.20.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1166.6.1.2.20.1 |
gx2CEBAnalogTableThis table contains gx2CEB specific parameters with
nominal and current values. SEQUENCE OF Gx2CEBAnalogEntry .1.3.6.1.4.1.1166.6.1.2.20.2 |
gx2CEBAnalogEntryThis list contains the analog parameters and descriptions. Gx2CEBAnalogEntry .1.3.6.1.4.1.1166.6.1.2.20.2.1 |
gx2CEBAnalogTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.2.1.1 |
ceblabelModTempThe value of this object provides the label of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.2 |
cebuomModTempThe value of this object provides the Unit of Measure of the
Module Temperature Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.3 |
cebmajorHighModTempThe value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.4 |
cebmajorLowModTempThe value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.5 |
cebminorHighModTempThe value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.6 |
cebminorLowModTempThe value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.7 |
cebcurrentValueModTempThe value of this object provides the Current value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.8 |
cebstateFlagModTempThe value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.9 |
cebminValueModTempThe value of this object provides the minimum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.10 |
cebmaxValueModTempThe value of this object provides the maximum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.11 |
cebalarmStateModTempThe value of this object provides the curent alarm state of
the Module Temperature Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.12 |
ceblabelFanCurrentThe value of this object provides the label of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.13 |
cebuomFanCurrentThe value of this object provides the Unit of Measure of the
Fan Current Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.14 |
cebmajorHighFanCurrentThe value of this object provides the Major High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.15 |
cebmajorLowFanCurrentThe value of this object provides the Major Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.16 |
cebminorHighFanCurrentThe value of this object provides the Minor High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.17 |
cebminorLowFanCurrentThe value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedroobsolete Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.18 |
cebcurrentValueFanCurrentThe value of this object provides the Current value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.19 |
cebstateFlagFanCurrentThe value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.20 |
cebminValueFanCurrentThe value of this object provides the minimum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.21 |
cebmaxValueFanCurrentThe value of this object provides the maximum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as
an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.22 |
cebalarmStateFanCurrentThe value of this object provides the curent alarm state of
the Fan Current Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.23 |
ceblabelAnalogVoltage01The value of this object provides the label of the
Analog Voltage number 01 Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.24 |
cebuomAnalogVoltage01The value of this object provides the Unit of Measure of the
Analog Voltage number 01 Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.25 |
cebmajorHighAnalogVoltage01The value of this object provides the Major High alarm value
Analog Voltage number 01 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.26 |
cebmajorLowAnalogVoltage01The value of this object provides the Major Low alarm value
Analog Voltage number 01 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.27 |
cebminorHighAnalogVoltage01The value of this object provides the Minor High alarm value
Analog Voltage number 01 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.28 |
cebminorLowAnalogVoltage01The value of this object provides the Minor Low alarm value
Analog Voltage number 01 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.29 |
cebcurrentValueAnalogVoltage01The value of this object provides the Current value
Analog Voltage number 01 Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.30 |
cebstateFlagAnalogVoltage01The value of this object provides the state of the
Analog Voltage number 01 Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.31 |
cebminValueAnalogVoltage01The value of this object provides the minimum value
the Analog Voltage number 01 Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.32 |
cebmaxValueAnalogVoltage01The value of this object provides the maximum value
the Analog Voltage number 01 Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.33 |
cebalarmStateAnalogVoltage01The value of this object provides the curent alarm state of
the Analog Voltage number 01 Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.34 |
ceblabelAnalogVoltage02The value of this object provides the label of the
Analog Voltage number 02 Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.35 |
cebuomAnalogVoltage02The value of this object provides the Unit of Measure of the
Analog Voltage number 02 Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.36 |
cebmajorHighAnalogVoltage02The value of this object provides the Major High alarm value
Analog Voltage number 02 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.37 |
cebmajorLowAnalogVoltage02The value of this object provides the Major Low alarm value
Analog Voltage number 02 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.38 |
cebminorHighAnalogVoltage02The value of this object provides the Minor High alarm value
Analog Voltage number 02 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.39 |
cebminorLowAnalogVoltage02The value of this object provides the Minor Low alarm value
Analog Voltage number 02 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.40 |
cebcurrentValueAnalogVoltage02The value of this object provides the Current value
Analog Voltage number 02 Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.41 |
cebstateFlagAnalogVoltage02The value of this object provides the state of the
Analog Voltage number 02 Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.42 |
cebminValueAnalogVoltage02The value of this object provides the minimum value
the Analog Voltage number 02 Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.43 |
cebmaxValueAnalogVoltage02The value of this object provides the maximum value
the Analog Voltage number 02 Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.44 |
cebalarmStateAnalogVoltage02The value of this object provides the curent alarm state of
the Analog Voltage number 02 Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.45 |
ceblabelAnalogVoltage03The value of this object provides the label of the
Analog Voltage number 03 Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.46 |
cebuomAnalogVoltage03The value of this object provides the Unit of Measure of the
Analog Voltage number 03 Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.47 |
cebmajorHighAnalogVoltage03The value of this object provides the Major High alarm value
Analog Voltage number 03 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.48 |
cebmajorLowAnalogVoltage03The value of this object provides the Major Low alarm value
Analog Voltage number 03 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.49 |
cebminorHighAnalogVoltage03The value of this object provides the Minor High alarm value
Analog Voltage number 03 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.50 |
cebminorLowAnalogVoltage03The value of this object provides the Minor Low alarm value
Analog Voltage number 03 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.51 |
cebcurrentValueAnalogVoltage03The value of this object provides the Current value
Analog Voltage number 03 Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.52 |
cebstateFlagAnalogVoltage03The value of this object provides the state of the
Analog Voltage number 03 Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.53 |
cebminValueAnalogVoltage03The value of this object provides the minimum value
the Analog Voltage number 03 Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.54 |
cebmaxValueAnalogVoltage03The value of this object provides the maximum value
the Analog Voltage number 03 Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.55 |
cebalarmStateAnalogVoltage03The value of this object provides the curent alarm state of
the Analog Voltage number 03 Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.56 |
ceblabelAnalogVoltage04The value of this object provides the label of the
Analog Voltage number 04 Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.57 |
cebuomAnalogVoltage04The value of this object provides the Unit of Measure of the
Analog Voltage number 04 Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.58 |
cebmajorHighAnalogVoltage04The value of this object provides the Major High alarm value
Analog Voltage number 04 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.59 |
cebmajorLowAnalogVoltage04The value of this object provides the Major Low alarm value
Analog Voltage number 04 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.60 |
cebminorHighAnalogVoltage04The value of this object provides the Minor High alarm value
Analog Voltage number 04 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.61 |
cebminorLowAnalogVoltage04The value of this object provides the Minor Low alarm value
Analog Voltage number 04 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.62 |
cebcurrentValueAnalogVoltage04The value of this object provides the Current value
Analog Voltage number 04 Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.63 |
cebstateFlagAnalogVoltage04The value of this object provides the state of the
Analog Voltage number 04 Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.64 |
cebminValueAnalogVoltage04The value of this object provides the minimum value
the Analog Voltage number 04 Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.65 |
cebmaxValueAnalogVoltage04The value of this object provides the maximum value
the Analog Voltage number 04 Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.66 |
cebalarmStateAnalogVoltage04The value of this object provides the curent alarm state of
the Analog Voltage number 04 Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.67 |
ceblabelAnalogVoltage05The value of this object provides the label of the
Analog Voltage number 05 Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.68 |
cebuomAnalogVoltage05The value of this object provides the Unit of Measure of the
Analog Voltage number 05 Analog parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.2.1.69 |
cebmajorHighAnalogVoltage05The value of this object provides the Major High alarm value
Analog Voltage number 05 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.70 |
cebmajorLowAnalogVoltage05The value of this object provides the Major Low alarm value
Analog Voltage number 05 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.71 |
cebminorHighAnalogVoltage05The value of this object provides the Minor High alarm value
Analog Voltage number 05 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.72 |
cebminorLowAnalogVoltage05The value of this object provides the Minor Low alarm value
Analog Voltage number 05 Analog parameter.
This value is a floating point number that is represented as
an IEEE 32 bit number. All F's indicate the parameter is unusedro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.73 |
cebcurrentValueAnalogVoltage05The value of this object provides the Current value
Analog Voltage number 05 Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.74 |
cebstateFlagAnalogVoltage05The value of this object provides the state of the
Analog Voltage number 05 Analog parameter.
(0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.75 |
cebminValueAnalogVoltage05The value of this object provides the minimum value
the Analog Voltage number 05 Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.76 |
cebmaxValueAnalogVoltage05The value of this object provides the maximum value
the Analog Voltage number 05 Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number.ro Float .1.3.6.1.4.1.1166.6.1.2.20.2.1.77 |
cebalarmStateAnalogVoltage05The value of this object provides the curent alarm state of
the Analog Voltage number 01 Analog parameter.ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.2.1.78 |
gx2CEBStatusTableThis table contains gx2CEB specific parameters with
nominal and current values. SEQUENCE OF Gx2CEBStatusEntry .1.3.6.1.4.1.1166.6.1.2.20.3 |
gx2CEBStatusEntryThis list contains Status parameters and descriptions. Gx2CEBStatusEntry .1.3.6.1.4.1.1166.6.1.2.20.3.2 |
gx2CEBStatusTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.3.2.1 |
ceblabelBootThe value of this object provides the label of the
Boot Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.3.2.2 |
cebvalueBootThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.3.2.3 |
cebstateflagBootThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.3.2.4 |
ceblabelFlashThe value of this object provides the label of the
Flash Status Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.3.2.5 |
cebvalueFlashThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.3.2.6 |
cebstateflagFlashThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.3.2.7 |
ceblabelFactoryDataCRCThe value of this object provides the label of the
Factory Data CRC Status parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.3.2.8 |
cebvalueFactoryDataCRCThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.3.2.9 |
cebstateflagFactoryDataCRCThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.3.2.10 |
ceblabelAlarmDataCrcThe value of this object provides the label of the
Alarm Data Crc parameter.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.3.2.11 |
cebvalueAlarmDataCrcThe value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.3.2.12 |
cebstateflagAlarmDataCrcThe value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).ro Enumeration .1.3.6.1.4.1.1166.6.1.2.20.3.2.13 |
gx2CEBFactoryTableThis table contains gx2CEB specific parameters with
nominal and current values. SEQUENCE OF Gx2CEBFactoryEntry .1.3.6.1.4.1.1166.6.1.2.20.4 |
gx2CEBFactoryEntryThis list contains Factory parameters and descriptions. Gx2CEBFactoryEntry .1.3.6.1.4.1.1166.6.1.2.20.4.3 |
gx2CEBFactoryTableIndexThe value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.4.3.1 |
cebbootControlByteThe value of this object indicates which bank the firmware
is currently being boot from.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.4.3.2 |
cebbootStatusByteThis object indicates the status of the last boot. Bit 2 =
Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail
and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail)ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.4.3.3 |
cebbank1CRCThis object provides the CRC code of bank 0. The display
formate for the data is Hex.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.4.3.4 |
cebbank2CRCThis object provides the CRC code of bank 1.The display
formate for the data is Hex.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.4.3.5 |
cebprgEEPROMByteThis object indicates if the EEPROM has been programmedro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.4.3.6 |
cebfactoryCRCThis object provides the CRC code for the Factory data.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.4.3.7 |
cebcalculateCRCThis object indicates which of the Enums will have the CRC
calculated.roobsolete Enumeration .1.3.6.1.4.1.1166.6.1.2.20.4.3.8 |
cebhourMeterThis object provides the hour meter reading of the module.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.4.3.9 |
cebflashPrgCntAThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.4.3.10 |
cebflashPrgCntBThis object provides the number of times Bank 1 flash has been
programmed.ro INTEGER .1.3.6.1.4.1.1166.6.1.2.20.4.3.11 |
cebflashBankARevThis object provides the revision of flash bank 0. The rev is
2 characters.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.4.3.12 |
cebflashBankBRevThis object provides the revision of flash bank 1. The rev is
2 characters.ro DisplayString .1.3.6.1.4.1.1166.6.1.2.20.4.3.13 |