MSERIES-ALARM-MIB
AI MIB Summary
The MSERIES-ALARM-MIB module enables SNMP-based monitoring of critical fault conditions and operational alerts on Nokia SmartOptics M-Series optical transport hardware. It specifically tracks alarm states, severity levels, and event triggers to facilitate real-time network fault detection and troubleshooting within the optical layer.
This is the enterprise specific Alarm MIB for SmartOptics M-Series
Main OID:
smartAlarm.1.3.6.1.4.1.30826.1.1
54
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
54 total| Object Name |
|---|
smartAlarmThis is the enterprise specific Alarm MIB for SmartOptics M-Series MODULE-IDENTITY .1.3.6.1.4.1.30826.1.1 |
alarmGeneral OBJECT IDENTIFIER .1.3.6.1.4.1.30826.1.1.1 |
smartAlarmGeneralLastSeqNumberThe sequence number of the last sent notification.ro Counter32 .1.3.6.1.4.1.30826.1.1.1.1 |
smartAlarmGeneralHighestSeverityThe current highest severity of the active alarms.ro AlarmPerceivedSeverity (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.1.2 |
smartAlarmGeneralNumberActiveListThe number of active alarms in the alarmActiveList.ro Unsigned32 .1.3.6.1.4.1.30826.1.1.1.3 |
smartAlarmGeneralNumberLogListThe number of alarms in the alarmLogList.ro Unsigned32 .1.3.6.1.4.1.30826.1.1.1.4 |
alarmActiveList OBJECT IDENTIFIER .1.3.6.1.4.1.30826.1.1.2 |
alarmActiveTableThe active alarm list. SEQUENCE OF AlarmEntry .1.3.6.1.4.1.30826.1.1.2.1 |
alarmEntryAn entry in the active alarm list. AlarmEntry .1.3.6.1.4.1.30826.1.1.2.1.1 |
alarmIndexAn unique index assigned to each alarm.ro Unsigned32 .1.3.6.1.4.1.30826.1.1.2.1.1.1 |
alarmUnitThe alarming unit associated with this alarm. undefined(0), nmb(1), psu1(2), psu2(3), fan(4), system(5), slaveNmb(6), slavePsu1(7), slavePsu2(8), slaveFan(9).ro UnitType (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.2 |
alarmPortThe alarming port associated with this alarm. 1-10 is Line Ports. 11 and higher is Client ports. For non port alarms this value is 0.ro Integer32 .1.3.6.1.4.1.30826.1.1.2.1.1.3 |
alarmTextThe additional text for the alarm.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.4 |
alarmSeverityThe severity of the alarm as defined in ITU-T X.733.ro AlarmPerceivedSeverity (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.5 |
alarmActivationTimeThe time when the alarm was created.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.6 |
alarmCeaseTimeThe time when the alarm was ceased.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.7 |
alarmSeqNumberThe last sequence number used when issuing a notification for this alarm.ro Counter32 .1.3.6.1.4.1.30826.1.1.2.1.1.8 |
alarmHostNameThe hostname.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.9 |
alarmPortNameThe Port Name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.10 |
alarmPortTypeThe Port Type. undefined(0), rx(1), tx(2), biDi(3).ro PortType (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.11 |
alarmTypeThe type of alarm as defined in ITU-T X.733 undefined (0), other (1), communicationsAlarm (2), qualityOfServiceAlarm (3), processingErrorAlarm (4), equipmentAlarm (5), environmental (6), integrityViolation (7), operationalViolation (8), physicalViolation(9), securityServiceOrMechanismViloation (10), timeDomainViolation (11)ro AlarmNotificationType (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.12 |
alarmCauseThe alarm probable cause as defined in ITU-T X.733. undefined (0) adapterError (1) -- Equipment applicationSubsystemFailure (2) -- Processing bandwidthReduced (3) -- Quality of service callEstablishmentError (4) -- Communications communicationsProtocolError (5) -- Communications communicationsSubsystemFailure (6) -- Communications configurationOrCustomizationError (7) -- Processing congestion (8) -- Quality of service corruptData (9) -- Processing cpuCyclesLimitExceeded (10) -- Processing dTEdCEInterfaceError (11) -- Communications datasetOrModemError (12) -- Equipment degradedSignal (13) -- Communications enclosureDoorOpen (14) -- Environmental equipmentMalfunction (15) -- Equipment excessiveVibration (16) -- Environmental fileError (17) -- Processing fireDetected (18) -- Environmental floodDetected (19) -- Environmental framingError (20) -- Communications heatingOrVentilationOrCoolingSystemProblem (21) -- Environmental humidityUnacceptable (22) -- Environmental inputDeviceError (23) -- Equipment inputOutputDeviceError (24) -- Equipment lANError (25) -- Communications leakDetected (26) -- Environmental localNodeTransmissionError (27) -- Communications lossOfFrame (28) -- Communications lossOfSignal (29) -- Communications materialSupplyExhausted (30) -- Environmental multiplexerProblem (31) -- Equipment outOfMemory (32) -- Processing outputDeviceError (33) -- Equipment performanceDegraded (34) -- Quality of service powerProblem (35) -- Equipment pressureUnacceptable (36) -- Environmental processorProblem (37) -- Equipment pumpFailure (38) -- Environmental queueSizeExceeded (39) -- Quality of service receiveFailure (40) -- Equipment receiverFailure (41) -- Equipment remoteNodeTransmissionError (42) -- Communications resourceAtOrNearingCapacity (43) -- Quality of service responseTimeExcessive (44) -- Quality of service retransmissionRateExcessive (45) -- Quality of service softwareProgramError (46) -- Processing softwareError (47) -- Processing softwareProgramAbnormallyTerminated (48) -- Processing storageCapacityProblem (49) -- Processing temperatureUnacceptable (50) -- Environmental thresholdCrossed (51) -- Quality of service timingProblem (52) -- Equipment toxicLeakDetected (53) -- Environmental transmitFailure (54) -- Equipment transmitterFailure (55) -- Equipment underlyingResourceUnavailable (56) -- Processing versionMismatch (57) -- Processingro AlarmProbableCause (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.13 |
alarmPortAliasThe Port Alias.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.2.1.1.14 |
alarmLogList OBJECT IDENTIFIER .1.3.6.1.4.1.30826.1.1.3 |
alarmLogTableThe active alarm list. SEQUENCE OF AlarmLogEntry .1.3.6.1.4.1.30826.1.1.3.1 |
alarmLogEntryAn entry in the alarm log table. AlarmLogEntry .1.3.6.1.4.1.30826.1.1.3.1.1 |
alarmLogIndexAn unique index assigned to each alarm.ro Unsigned32 .1.3.6.1.4.1.30826.1.1.3.1.1.1 |
alarmLogUnitThe alarming unit associated with this alarm. undefined(0), nmb(1), psu1(2), psu2(3), fan(4), system(5), slaveNmb(6), slavePsu1(7), slavePsu2(8), slaveFan(9).ro UnitType (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.3.1.1.2 |
alarmLogPortThe alarming port associated with this alarm. 1-10 is Line Ports. 11 and higher is Client ports. For non port alarms this value is 0.ro Integer32 .1.3.6.1.4.1.30826.1.1.3.1.1.3 |
alarmLogTextThe additional text for the alarm.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.3.1.1.4 |
alarmLogSeverityThe severity of the alarm as defined in ITU-T X.733.ro AlarmPerceivedSeverity (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.3.1.1.5 |
alarmLogActivationTimeThe time when the alarm was created.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.3.1.1.6 |
alarmLogCeaseTimeThe time when the alarm was ceased.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.3.1.1.7 |
alarmLogSeqNumberThe last sequence number used when issuing a notification for this alarm.ro Counter32 .1.3.6.1.4.1.30826.1.1.3.1.1.8 |
alarmLogHostNameThe hostname.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.3.1.1.9 |
alarmLogPortNameThe Port Name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.30826.1.1.3.1.1.10 |
alarmLogPortTypeThe Port Direction. rx(1), tx(2), biDi(3).ro PortType (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.3.1.1.11 |
alarmLogTypeThe type of alarm as defined in ITU-T X.733 undefined (0), other (1), communicationsAlarm (2), qualityOfServiceAlarm (3), processingErrorAlarm (4), equipmentAlarm (5), environmental (6), integrityViolation (7), operationalViolation (8), physicalViolation(9), securityServiceOrMechanismViloation (10), timeDomainViolation (11)ro AlarmNotificationType (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.3.1.1.12 |
alarmLogCauseThe alarm probable cause as defined in ITU-T X.733. undefined (0) adapterError (1) -- Equipment applicationSubsystemFailure (2) -- Processing bandwidthReduced (3) -- Quality of service callEstablishmentError (4) -- Communications communicationsProtocolError (5) -- Communications communicationsSubsystemFailure (6) -- Communications configurationOrCustomizationError (7) -- Processing congestion (8) -- Quality of service corruptData (9) -- Processing cpuCyclesLimitExceeded (10) -- Processing dTEdCEInterfaceError (11) -- Communications datasetOrModemError (12) -- Equipment degradedSignal (13) -- Communications enclosureDoorOpen (14) -- Environmental equipmentMalfunction (15) -- Equipment excessiveVibration (16) -- Environmental fileError (17) -- Processing fireDetected (18) -- Environmental floodDetected (19) -- Environmental framingError (20) -- Communications heatingOrVentilationOrCoolingSystemProblem (21) -- Environmental humidityUnacceptable (22) -- Environmental inputDeviceError (23) -- Equipment inputOutputDeviceError (24) -- Equipment lANError (25) -- Communications leakDetected (26) -- Environmental localNodeTransmissionError (27) -- Communications lossOfFrame (28) -- Communications lossOfSignal (29) -- Communications materialSupplyExhausted (30) -- Environmental multiplexerProblem (31) -- Equipment outOfMemory (32) -- Processing outputDeviceError (33) -- Equipment performanceDegraded (34) -- Quality of service powerProblem (35) -- Equipment pressureUnacceptable (36) -- Environmental processorProblem (37) -- Equipment pumpFailure (38) -- Environmental queueSizeExceeded (39) -- Quality of service receiveFailure (40) -- Equipment receiverFailure (41) -- Equipment remoteNodeTransmissionError (42) -- Communications resourceAtOrNearingCapacity (43) -- Quality of service responseTimeExcessive (44) -- Quality of service retransmissionRateExcessive (45) -- Quality of service softwareProgramError (46) -- Processing softwareError (47) -- Processing softwareProgramAbnormallyTerminated (48) -- Processing storageCapacityProblem (49) -- Processing temperatureUnacceptable (50) -- Environmental thresholdCrossed (51) -- Quality of service timingProblem (52) -- Equipment toxicLeakDetected (53) -- Environmental transmitFailure (54) -- Equipment transmitterFailure (55) -- Equipment underlyingResourceUnavailable (56) -- Processing versionMismatch (57) -- Processingro AlarmProbableCause (MSERIES-TC) .1.3.6.1.4.1.30826.1.1.3.1.1.13 |
alarmNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.30826.1.1.4 |
alarmNotifyPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.30826.1.1.4.0 |
alarmNotificationClearedSent when an alarm is cleared. NOTIFICATION-TYPE .1.3.6.1.4.1.30826.1.1.4.0.1 |
alarmNotificationWarningSent when an alarm with warning severity is activated. NOTIFICATION-TYPE .1.3.6.1.4.1.30826.1.1.4.0.2 |
alarmNotificationMinorSent when an alarm with minor severity is activated. NOTIFICATION-TYPE .1.3.6.1.4.1.30826.1.1.4.0.3 |
alarmNotificationMajorSent when an alarm with major severity is activated.. NOTIFICATION-TYPE .1.3.6.1.4.1.30826.1.1.4.0.4 |
alarmNotificationCriticalSent when an alarm with critical severity is activated. NOTIFICATION-TYPE .1.3.6.1.4.1.30826.1.1.4.0.5 |
smartAlarmMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.30826.1.1.5 |
smartAlarmGroups OBJECT IDENTIFIER .1.3.6.1.4.1.30826.1.1.5.1 |
smartAlarmGeneralGroupV1The general alarm objects V1. Unknown .1.3.6.1.4.1.30826.1.1.5.1.1 |
smartAlarmNotificationGroupV1The alarm notifications V1. Unknown .1.3.6.1.4.1.30826.1.1.5.1.2 |
smartAlarmActiveTableGroupV1The active alarm table objects V1. Unknown .1.3.6.1.4.1.30826.1.1.5.1.3 |
smartAlarmLogTableGroupV1The alarm log table objects V1. Unknown .1.3.6.1.4.1.30826.1.1.5.1.4 |
smartAlarmCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.30826.1.1.5.2 |
smartAlarmBasicComplV1Basic implementation requirements for the alarm MIB V1. Unknown .1.3.6.1.4.1.30826.1.1.5.2.1 |