KST-2000AB
The KST-2000AB MIB module enables SNMP-based monitoring and management of KST-2000A/B optical transceivers, providing access to critical operational metrics such as optical power levels, laser bias currents, temperature, and voltage status. This module facilitates real-time fault detection and performance tracking for these specific transceiver hardware units within network infrastructure.
Imported Objects
Objects
38 total| Object Name |
|---|
kst2000ABModule Identity for KST-2000A/B Transceiver. MODULE-IDENTITY .1.3.6.1.4.1.6247.30 |
kst2000ABObjects OBJECT IDENTIFIER .1.3.6.1.4.1.6247.30.1 |
kstSystemInfo OBJECT IDENTIFIER .1.3.6.1.4.1.6247.30.1.1 |
kstEquipmentTypeKST Equipment Type. (RET?)ro OCTET STRING .1.3.6.1.4.1.6247.30.1.1.1 |
kstSerialNumbersKST-2000A/B Serial Numbers. (SNM?)ro OCTET STRING .1.3.6.1.4.1.6247.30.1.1.2 |
kstAssemblyNumbersKST-2000A/B Assembly Numbers. (ANM?)ro OCTET STRING .1.3.6.1.4.1.6247.30.1.1.3 |
kstFirmwareNumbersKST-2000A/B Firmware Numbers and Versions. (FRM?)ro OCTET STRING .1.3.6.1.4.1.6247.30.1.1.4 |
kstUnitParameters OBJECT IDENTIFIER .1.3.6.1.4.1.6247.30.1.2 |
kstCircuitIDKST-2000A/B Unit Circuit ID. (CID?, CID=)rw OCTET STRING .1.3.6.1.4.1.6247.30.1.2.1 |
kstAgcKST-2000A/B Unit AGC. (AGC?, AGC=)rw Enumeration .1.3.6.1.4.1.6247.30.1.2.2 |
kstRefOscillatorAdjustKST-2000A/B Reference Oscillator Adjust. (REF?, REF=)rw INTEGER .1.3.6.1.4.1.6247.30.1.2.3 |
kstLockModeKST-2000A/B Lock Mode. (LOK?, LOK=)rw Enumeration .1.3.6.1.4.1.6247.30.1.2.4 |
kstTxParameters OBJECT IDENTIFIER .1.3.6.1.4.1.6247.30.1.3 |
kstUpConvFrequencyKST-2000A/B Up Converter Frequency. (UFQ?, UFQ=)rw INTEGER .1.3.6.1.4.1.6247.30.1.3.1 |
kstUpConvAttenuationKST-2000A/B Up Converter Attenuation. (UAT?, UAT=)rw INTEGER .1.3.6.1.4.1.6247.30.1.3.2 |
kstUpConvOutputKST-2000A/B Up Converter Output. (UMU?, UMU=)rw Enumeration .1.3.6.1.4.1.6247.30.1.3.3 |
kstHpaPowerEnableKST-2000A/B HPA Power Enable. (AMP?, AMP=)rw Enumeration .1.3.6.1.4.1.6247.30.1.3.4 |
kstHpaFaultLogicKST-2000A/B HPA Fault Logic. (KFE?, KFE=)rw Enumeration .1.3.6.1.4.1.6247.30.1.3.5 |
kstRxParameters OBJECT IDENTIFIER .1.3.6.1.4.1.6247.30.1.4 |
kstDownConvFrequencyKST-2000A/B Down Converter Frequency. (DFQ?, DFQ=)rw INTEGER .1.3.6.1.4.1.6247.30.1.4.1 |
kstDownConvAttenuationKST-2000A/B Down Converter Attenuation. (DAT?, DAT=)rw INTEGER .1.3.6.1.4.1.6247.30.1.4.2 |
kstReceiveBandKST-2000B Receive Band. (SRB?, SRB=) SRB=x, where x is, A = band 10950 to 11700 MHz B = band 11700 to 12200 MHz C = band 12250 to 12750 MHzrw Enumeration .1.3.6.1.4.1.6247.30.1.4.3 |
kstLnaPowerEnableKST-2000A/B LNA Power Enable. (LCS?, LCS=)rw Enumeration .1.3.6.1.4.1.6247.30.1.4.4 |
kstLnaFaultLogicKST-2000A/B LNA Fault Logic. (LFL?, LFL=)rw Enumeration .1.3.6.1.4.1.6247.30.1.4.5 |
kstUnitStatus OBJECT IDENTIFIER .1.3.6.1.4.1.6247.30.1.5 |
kstUnitFaultStatusKST-2000A/B Unit Fault Status. (CFS?, CFS=) CFS=ABCDEFG, where A = Common Equipment Status, 0=OK, 1=FLT B = Reference Status, 0=OK, 1=FLT C = AGC Status, 0=OK, 1=FLT D = Up Converter Status, 0=OK, 1=FLT E = Down Converter Status, 0=OK, 1=FLT F = HPA Status, 0=OK, 1=FLT G = LNA Status, 0=OK, 1=FLTro OCTET STRING .1.3.6.1.4.1.6247.30.1.5.1 |
kstCommonEquipmentStatusKST-2000A/B Common Equipment Status. (CES?, CES=) CES=ABCD, where A = -7V PS Status, 0=OK, 1=FLT B = +7V PS Status, 0=OK, 1=FLT C = +12V PS Status, 0=OK, 1=FLT D = +17V PS Status, 0=OK, 1=FLTro OCTET STRING .1.3.6.1.4.1.6247.30.1.5.2 |
kstReferenceStatusKST-2000A/B Reference Status. (CRS?, CRS=) CRS=ABCDEF, where A = REF Source, 0=INT, 1=EXT B = Oscillator State, 0=COLD, 1=WARM C = 72M Lock Status, 0=OK, 1=FLT D = EXT REF Lock Status, 0=OK, 1=FLT, 2=NA E = EXT REF Phase_N Status, 0=OK, 1=FLT, 2=NA F = EXT REF Range Status, 0=OK, 1=FLT, 2=NAro OCTET STRING .1.3.6.1.4.1.6247.30.1.5.3 |
kstAgcStatusKST-2000A/B AGC Status. (CAS?, CAS=) CAS=ABC, where A = Loop Convergence, 0=OK, 1=FLT B = Excessive Input Power (EIP), 0=OK, 1=FLT C = Insufficient Input Power (IIP), 0=OK, 1=FLTro OCTET STRING .1.3.6.1.4.1.6247.30.1.5.4 |
kstUpConvStatusKST-2000A/B Up Converter Status. (CUS?, CUS=) CUS=ABCD, where A = Overtemperature Status, 0=OK, 1=FLT B = L-Band Synthesizer Lock Status, 0=OK, 1=FLT C = Ku-Band Synthesizer Lock Status, 0=OK, 1=FLT D = Interprocessor Comm. Status, 0=OK, 1=FLTro OCTET STRING .1.3.6.1.4.1.6247.30.1.5.5 |
kstDownConvStatusKST-2000A/B Down Converter Status. (CDS?, CDS=) CDS=ABCD, where A = Overtemperature Status, 0=OK, 1=FLT B = L-Band Synthesizer Lock Status, 0=OK, 1=FLT C = Ku-Band Synthesizer Lock Status, 0=OK, 1=FLT D = Interprocessor Comm. Status, 0=OK, 1=FLTro OCTET STRING .1.3.6.1.4.1.6247.30.1.5.6 |
kstHpaStatusKST-2000A/B HPA Status. (CHS?, CHS=) CHS=ABCDE, where A = Overtemperature Status, 0=OK, 1=FLT, 2=NA B = +9.5V Status, 0=OK, 1=FLT, 2=NA C = -5V Status, 0=OK, 1=FLT, 2=NA D = BIAS Voltage Summary Status, 0=OK, 1=FLT, 2=NA E = Interprocessor Comm. Status, 0=OK, 1=FLT, 2=NAro OCTET STRING .1.3.6.1.4.1.6247.30.1.5.7 |
kstLnaStatusKST-2000A/B LNA Status. 0=OK, 1=FLTro OCTET STRING .1.3.6.1.4.1.6247.30.1.5.8 |
kst2000ABConformance OBJECT IDENTIFIER .1.3.6.1.4.1.6247.30.2 |
kst2000ABGroups OBJECT IDENTIFIER .1.3.6.1.4.1.6247.30.2.1 |
kst2000ABObjectsGroupKST-2000A/B Objects Group. Unknown .1.3.6.1.4.1.6247.30.2.1.1 |
kst2000ABCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.6247.30.2.2 |
kst2000ABComplianceKST-2000A/B Compliance. Unknown .1.3.6.1.4.1.6247.30.2.2.1 |
More MIBs from Comtech EF Data
Browse all Comtech EF DataMIBs →The CDD-564 MIB module enables monitoring and management of CDD-564 satellite demodulator hardware, specifically tracking RF signal parameters, demodulation status, error rates, and link health metrics. This module facilitates the collection of performance counters and alarm states required for maintaining satellite communication link integrity and troubleshooting demodulation failures.
SNMP MIB module
SNMP MIB module
Standard SNMP MIB module defining data structures for EFDATA-MIB.
Standard SNMP MIB module defining data structures for EFDATA-SPECTRACAST-DR5000-MIB.
The CSAT-5060 MIB module provides management interfaces for the Cisco CSAT-5060 Transceiver, enabling monitoring of optical transceiver parameters such as temperature, voltage, bias current, and optical power levels. It facilitates real-time health assessment and fault detection for the physical layer components of the associated Cisco router or switch hardware.