EFDATA-SPECTRACAST-DR5000-MIB
Standard SNMP MIB module defining data structures for EFDATA-SPECTRACAST-DR5000-MIB.
Imported Objects
Objects
83 total| Object Name |
|---|
efdata OBJECT IDENTIFIER .1.3.6.1.4.1.6247 |
spectracast OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3 |
dr5000 OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2 |
general OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.1 |
softwareVersionSoftware Version (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.1.1 |
hardwareVersionHardware Version (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.1.2 |
macAddressMAC address (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.1.3 |
multicastRoutingStatusMulticast routing status (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.1.4 |
rfparameters OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.2 |
rf-InputRF Input frequency (MHz) (read-write).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.2.1 |
lnb-FrequencyLNB frequency (GHz) (read-write).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.2.2 |
symbolRateSymbol rate (Msps) (read-write).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.2.3 |
polarityPolarity may take values: Disabled(0), Vertical(14) or Horizontal(18) (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.2.4 |
frequencyRangeFrequency range may take values: Low(0) or High(1) (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.2.5 |
dvbparameters OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.3 |
pids-numberNumber of PIDs in the list (read only).ro INTEGER .1.3.6.1.4.1.6247.3.2.3.1 |
pidTableList of PID entries. The number of entries is given by PIDs-number value. SEQUENCE OF PIDentry .1.3.6.1.4.1.6247.3.2.3.2 |
pidEntryPID entry containing objects for the particular PID. PIDentry .1.3.6.1.4.1.6247.3.2.3.2.1 |
pidindexUnique ID for each PID, ranges between 1 and PIDs-number (read-only).ro INTEGER .1.3.6.1.4.1.6247.3.2.3.2.1.1 |
pidvalueUnique PID value (read-write).rw INTEGER .1.3.6.1.4.1.6247.3.2.3.2.1.2 |
ccuparameters OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.4 |
ccuConnectionModeCCU connection mode, may take values: Manual(0), Duplex(1) or Simplex(2) (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.4.1 |
ccuIpAddressCCU IP Address (read-write).rw IpAddress .1.3.6.1.4.1.6247.3.2.4.2 |
ccuUserNameUser name for connecting to the CCU (write only).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.4.3 |
ccuPasswordPassword for connecting to the CCU (write only).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.4.4 |
encryptedMulticastSet to Enabled in order to receive encrypted multicast.rw Enumeration .1.3.6.1.4.1.6247.3.2.4.5 |
dialupparameters OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.5 |
connectionModeConnection Mode, may take values: Manual(0) or Automatic(1) (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.5.1 |
phoneNumberISP Phone number, accepts only digits (read-write).rw INTEGER .1.3.6.1.4.1.6247.3.2.5.2 |
userNameUser name for dialup connection (write only).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.5.3 |
passwordPassword for dialup connection (write only).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.5.4 |
dialToneDialing mode, may take values: Tone(0)) or Pulse(1) (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.5.5 |
speedModem connection speed, may take values: 9600, 19200, 38400, 57600 or 115200 (read-write).rw INTEGER .1.3.6.1.4.1.6247.3.2.5.7 |
idleTimeOutDial on demand time out in minutes.
Set to 0 in order to disable dial on demand (read-write).rw INTEGER .1.3.6.1.4.1.6247.3.2.5.8 |
authenticationAuthentication mode, may take values: PAP or CHAP (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.5.9 |
status OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.6 |
initializationStatusCard initialization status (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.6.1 |
demodulatorStatusCurrent demodulator status (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.6.2 |
spectralInversionSpectral inversion (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.6.3 |
ber-before-Err-CorrectionBER before error correction (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.6.4 |
fecFEC (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.6.5 |
agcGain value set by AGC (Db) (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.6.6 |
frequencyOffsetFrequency offset (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.6.7 |
eb-N0Eb/N0 (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.6.8 |
ccu-connection-statusCCU connection status, may take values Disconnected(0), Connected(1), Trying to Connect(2),
Waiting for Dialup(3), or Waiting for RF Lock(4) (read only).ro Enumeration .1.3.6.1.4.1.6247.3.2.6.9 |
dialup-connection-statusDialup connection status, may take values Disconnected(0), Connected(1), Trying to Connect(2)
or Idle(10) (read only).ro Enumeration .1.3.6.1.4.1.6247.3.2.6.10 |
flowStatistics OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.7 |
totalThroughputTotal throughput in bytes/sec. (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.7.1 |
unicastThroughputUnicast throughput in bytes/sec. (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.7.2 |
multicastThroughputMulticast throughput in bytes/sec. (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.7.3 |
totalPacketsTotal packets received since reset (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.7.4 |
badPacketsBad RS packets (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.7.5 |
correctedPacketsCorrected RS packets (read only).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.7.6 |
resetFlowStatisticsSet to True in order to reset flow statistics.rw Enumeration .1.3.6.1.4.1.6247.3.2.7.7 |
maintenance OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.8 |
driverRestartSet to True in order to restart the Driver.rw Enumeration .1.3.6.1.4.1.6247.3.2.8.1 |
dialupConnectSet to True in order to dial your ISP.rw Enumeration .1.3.6.1.4.1.6247.3.2.8.2 |
dialupDisconnectSet to true in order to disconnect from your ISP.rw Enumeration .1.3.6.1.4.1.6247.3.2.8.3 |
ccuconnectSet to True in order to connect to the CCU.rw Enumeration .1.3.6.1.4.1.6247.3.2.8.4 |
ccudisconnectSet to True in order to disconnect from the CCU.rw Enumeration .1.3.6.1.4.1.6247.3.2.8.5 |
upgradeSet to the upgrade file name, and upgrade the system.
After upgrade finishes the system reboots automatically (write only).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6247.3.2.8.6 |
snmpVariables OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.9 |
enableTrapsSet to True in order to start getting traps.rw Enumeration .1.3.6.1.4.1.6247.3.2.9.1 |
snmpManagerIPIP address of SNMP manager where traps have to be sent to (read-write).rw IpAddress .1.3.6.1.4.1.6247.3.2.9.2 |
trapPeriodTrap sending period in seconds (read-write).rw INTEGER .1.3.6.1.4.1.6247.3.2.9.3 |
trapList OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.9.4 |
multicastDaemon OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.9.4.1 |
multicastTrapEnableUse multicast daemon status trap. A trap message is sent when multicast
daemon goes down (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.9.4.1.1 |
demodulator OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.9.4.2 |
demodulatorTrapEnableUse demodulator status trap. A trap message is sent when the demodulator
loses data lock (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.9.4.2.1 |
ccuConnection OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.9.4.3 |
ccuTrapEnableUse CCU connection status trap. A trap message is sent when CCU status changes from
Connected to any other one (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.9.4.3.1 |
dialup OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.9.4.4 |
dialupTrapEnableUse dialup connection status trap. A trap message is sent when dialup status changes
from Connected to any other one except Idle (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.9.4.4.1 |
berLevel OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.9.4.5 |
berTrapEnableUse BER level trap. A trap message is sent when BER value is greater
then BER trap threshold (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.9.4.5.1 |
berThresholdBER level threshold value (read-write).rw OCTET STRING .1.3.6.1.4.1.6247.3.2.9.4.5.2 |
freqOffset OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.9.4.6 |
freqOffsetTrapEnableUse frequency offset trap. A trap message is sent when absolute frequency offset is greater
then frequency offset trap threshold (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.9.4.6.1 |
freqOffsetThresholdFrequency offset threshold value (read-write).rw OCTET STRING .1.3.6.1.4.1.6247.3.2.9.4.6.2 |
agcLevel OBJECT IDENTIFIER .1.3.6.1.4.1.6247.3.2.9.4.7 |
agcTrapEnableUse AGC level trap. A trap message is sent when gain value is greater
then AGC trap threshold (read-write).rw Enumeration .1.3.6.1.4.1.6247.3.2.9.4.7.1 |
agcThresholdAGC threshold value (read-write)rw OCTET STRING .1.3.6.1.4.1.6247.3.2.9.4.7.2 |
More MIBs from Comtech EF Data
Browse all Comtech EF DataMIBs →The CDD-564 MIB module enables monitoring and management of CDD-564 satellite demodulator hardware, specifically tracking RF signal parameters, demodulation status, error rates, and link health metrics. This module facilitates the collection of performance counters and alarm states required for maintaining satellite communication link integrity and troubleshooting demodulation failures.
SNMP MIB module
Standard SNMP MIB module defining data structures for EFDATA-MIB.
SNMP MIB module
The CSAT-5060 MIB module provides management interfaces for the Cisco CSAT-5060 Transceiver, enabling monitoring of optical transceiver parameters such as temperature, voltage, bias current, and optical power levels. It facilitates real-time health assessment and fault detection for the physical layer components of the associated Cisco router or switch hardware.
The CDM-570L MIB module provides management and monitoring capabilities for CDM-570 L-Band and IF-Band satellite modems, exposing performance metrics such as signal strength, bit error rates, modem status, and interface statistics. This module enables network administrators to track link quality, diagnose transmission errors, and manage configuration parameters specific to these satellite communication devices.