Home/Catalog/CDM-570L

CDM-570L

AI MIB Summary

The CDM-570L MIB module provides management and monitoring capabilities for CDM-570 L-Band and IF-Band satellite modems, exposing performance metrics such as signal strength, bit error rates, modem status, and interface statistics. This module enables network administrators to track link quality, diagnose transmission errors, and manage configuration parameters specific to these satellite communication devices.

Module Identity for both CDM-570 L-Band and IF-Band Satellite Modems.
Main OID:
cdm570.1.3.6.1.4.1.6247.24
47
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

47 total
Object Name
cdm570Module Identity for both CDM-570 L-Band and IF-Band Satellite Modems.
MODULE-IDENTITY
.1.3.6.1.4.1.6247.24
cdm570LBUCOptionBUC option, where: 0 = None 1 = 100 watt 2 = 150 wattro
Enumeration
.1.3.6.1.4.1.6247.24.1.1.2.7
cdm570LAlarmMaskBUCBUC alarm mask, where: 0 = Unmasked 1 = Maskedrw
Enumeration
.1.3.6.1.4.1.6247.24.1.2.7.9
cdm570LAlarmMaskLNBLNB alarm mask, where: 0 = Unmasked 1 = Maskedrw
Enumeration
.1.3.6.1.4.1.6247.24.1.2.7.10
cdm570LBUC
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.1.2.8.1
cdm570LBUCDCPowerBUC power control, where: 0 = Disable BUC DC Power 1 = Enable BUC DC Powerrw
Enumeration
.1.3.6.1.4.1.6247.24.1.2.8.1.1
cdm570LBUCFSK
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.1.2.8.1.2
cdm570LBUCCommsEnables or disables communication, via the FSK link, with an externally connected Block Up Converted (BUC), where: 0 = Disabled 1 = Enabledrw
Enumeration
.1.3.6.1.4.1.6247.24.1.2.8.1.2.1
cdm570LBUCAddressIndicates the BUC address, between 1 and 15.rw
INTEGER
.1.3.6.1.4.1.6247.24.1.2.8.1.2.2
cdm570LBUCRFOutputIndicates BUC output enable, where: 0 = Off (output disabled) 1 = On (output enabled)rw
Enumeration
.1.3.6.1.4.1.6247.24.1.2.8.1.2.3
cdm570LBUC10MHzReferenceEnables or disables the 10 MHz frequency reference to the BUC, where: 0 = Disabled 1 = Enabledrw
Enumeration
.1.3.6.1.4.1.6247.24.1.2.8.1.3
cdm570LBUCAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.1.2.8.1.4
cdm570LBUCHighCurrentLimitBUC high current limit, between 500 and 4000 mA.rw
INTEGER
.1.3.6.1.4.1.6247.24.1.2.8.1.4.1
cdm570LBUCLowCurrentLimitBUC low current limit, between 0 and 3000 mA. BUC low current limit must not exceed BUC high current limit.rw
INTEGER
.1.3.6.1.4.1.6247.24.1.2.8.1.4.2
cdm570LBUCLO
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.1.2.8.1.5
cdm570LBUCLOFrequencyBUC transmit LO frequency in the range of 3000 to 65000 MHz. Setting 0 disables this feature. Terminal Frequency = BUC_LO +/- Tx_Frequency (depending on LO mix).rw
INTEGER (0 | 3000..65000) UNITS "MHz"
.1.3.6.1.4.1.6247.24.1.2.8.1.5.1
cdm570LBUCLOMixBUC LO frequency mix, where: 0 = Low-side mix 1 = High-side mixrw
Enumeration
.1.3.6.1.4.1.6247.24.1.2.8.1.5.2
cdm570LLNB
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.1.2.8.2
cdm570LLNBDCPowerLNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltagerw
Enumeration
.1.3.6.1.4.1.6247.24.1.2.8.2.1
cdm570LLNB10MHzReferenceLNB 10MHz frequency reference, where: 0 = Disable LNB 10MHz reference 1 = Enable LNB 10MHz referencerw
Enumeration
.1.3.6.1.4.1.6247.24.1.2.8.2.2
cdm570LLNBAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.1.2.8.2.3
cdm570LLNBHighCurrentLimitLNB upper alarm limit for current, between 50 and 600 mA.rw
INTEGER
.1.3.6.1.4.1.6247.24.1.2.8.2.3.1
cdm570LLNBLowCurrentLimitLNB lower alarm limit for current, between 10 and 400 mA.rw
INTEGER
.1.3.6.1.4.1.6247.24.1.2.8.2.3.2
cdm570LLNBLO
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.1.2.8.2.4
cdm570LLNBLOFrequencyLNB receieve LO frequency, in the range of 3000 to 65000 MHz. Setting a 0 disables the feature. Terminal Frequency = LNB_LO +/- Rx_Frequency (depending on High/Low Mix)rw
INTEGER (0 | 3000..65000) UNITS "MHz"
.1.3.6.1.4.1.6247.24.1.2.8.2.4.1
cdm570LLNBLOMixLO frequency mix, where: 0 = Low-side mix 1 = High-side mixrw
Enumeration
.1.3.6.1.4.1.6247.24.1.2.8.2.4.2
cdm570LODUAlarmsODU Faults Value Description of status parameter 0 No ODU faults 1 BUC PLL 3 BUC current 5 BUC voltage 7 LNB current 9 LNB voltage 11 BUC temperature 13 BUC checksumro
Enumeration
.1.3.6.1.4.1.6247.24.1.3.1.4
cdm570LBUCParams
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.1.3.6.1
cdm570LBUCCurrentIndicates the value of the BUC current, between 0 and 9999 mA. Units = mA.ro
INTEGER
.1.3.6.1.4.1.6247.24.1.3.6.1.1
cdm570LBUCVoltageIndicates the value ofthe BUC voltage, between 0 and 64 volts in 0.1 volts. Units = 0.1 volts.ro
INTEGER
.1.3.6.1.4.1.6247.24.1.3.6.1.2
cdm570LBUCTemperatureIndicates the BUC temperature in degrees Celsius. If not available, response is -99. Note: This query is only valid when FSK and BUC power are turned On.ro
INTEGER (-99..99) UNITS "degrees Celsius"
.1.3.6.1.4.1.6247.24.1.3.6.1.3
cdm570LBUCSoftwareVersionIndicates the BUC software version, between 1 and 15. If not available, response is 0.ro
INTEGER (0 | 1..15)
.1.3.6.1.4.1.6247.24.1.3.6.1.4
cdm570LBUCPLLAlarmBUC PLL lock state, where: 0 = Locked 1 = Unlocked 9 = Unavailablero
Enumeration
.1.3.6.1.4.1.6247.24.1.3.6.1.5
cdm570LBUCPowerLevelBUC output power level in 0.1 watts. Units = 0.1 watts. Returns 0 when FSK and BUC power are not enabled.ro
INTEGER
.1.3.6.1.4.1.6247.24.1.3.6.1.6
cdm570LBUCTerminalTxFrequencyTerminal Tx Frequency = BUC_LO +/- Tx_Frequency (depending on LO mix) Units = 100 Hz Resolution = 100 Hz Returns 0 if BUC LO is zero.ro
INTEGER
.1.3.6.1.4.1.6247.24.1.3.6.1.7
cdm570LLNBParams
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.1.3.6.2
cdm570LLNBCurrentIndicates the value of the LNB current, between 0 and 999 mA.ro
INTEGER
.1.3.6.1.4.1.6247.24.1.3.6.2.1
cdm570LLNBVoltageIndicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0.ro
INTEGER
.1.3.6.1.4.1.6247.24.1.3.6.2.2
cdm570LLNBTerminalRxFrequencyTerminal Rx frequency = LNB LO +/- Rx_Frequency (depending on LO mix) Units = 100 Hz Resolution = 100 Hz Returns 0 if LNB_LO is zero.ro
INTEGER
.1.3.6.1.4.1.6247.24.1.3.6.2.3
cdm570Notifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.2
cdm570NotificationsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.2.0
cdm570LODUAlarmCDM-570L BUC and LNB ODU Alarm Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.6247.24.2.0.4
cdm570LGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.3.3
cdm570LObjectsGroupCDM-570L Objects Group.
Unknown
.1.3.6.1.4.1.6247.24.3.3.1
cdm570LNotificationsGroupCDM-570L Notifications Group.
Unknown
.1.3.6.1.4.1.6247.24.3.3.2
cdm570LCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.6247.24.3.4
cdm570LComplianceCDM-570L Compliance.
Unknown
.1.3.6.1.4.1.6247.24.3.4.1
CDM-570L - SNMP MIB Reference | MIBs Explorer