Home/Catalog/IEEE8021-PE-MIB

IEEE8021-PE-MIB

AI MIB Summary

The IEEE8021-PE-MIB provides management interfaces for monitoring Bridge Port Extension (PE) devices compliant with IEEE 802.1BR-2012, specifically tracking port states, extension link status, and traffic statistics for remote bridge ports. It enables the configuration and observation of PE-specific parameters such as port aggregation, VLAN mapping, and link aggregation group (LAG) membership within the extended bridge domain.

The PE MIB module for managing devices that support Bridge Port Extension. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1BR-2012. Copyright (C) IEEE. This version of this MIB module is part of IEEE 802.1BR-2012; see the specification itself for full legal notices.
Main OID:
ieee8021BridgePEMib.1.3.111.2.802.1.1.25
37
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

37 total
Object Name
ieee8021BridgePEMibThe PE MIB module for managing devices that support Bridge Port Extension. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1BR-2012. Copyright (C) IEEE. This version of this MIB module is part of IEEE 802.1BR-2012; see the specification itself for full legal notices.
MODULE-IDENTITY
.1.3.111.2.802.1.1.25
ieee8021BridgePENotifications
OBJECT IDENTIFIER
.1.3.111.2.802.1.1.25.1
ieee8021BridgePEObjects
OBJECT IDENTIFIER
.1.3.111.2.802.1.1.25.2
ieee8021BridgePEPortTableA table that contains per port information related to Port Extension. A row is created in this table for any port on a Controlling Bridge that is extended using Port Extension, including those ports that provide communication to the Port Extenders themselves.
SEQUENCE OF Ieee8021BridgePEPortEntry
.1.3.111.2.802.1.1.25.2.1
ieee8021BridgePEPortEntryA list of per port Port Extension objects.
Ieee8021BridgePEPortEntry
.1.3.111.2.802.1.1.25.2.1.1
ieee8021BridgePEPortComponentIdThe component identifier is used to distinguish between the multiple virtual bridge instances within a PBB. In simple situations where there is only a single component the default value is 1.
IEEE8021PbbComponentIdentifier (IEEE8021-TC-MIB)
.1.3.111.2.802.1.1.25.2.1.1.1
ieee8021BridgePEPortThe port number of the port for which this entry contains bridge management information.
IEEE8021BridgePortNumber (IEEE8021-TC-MIB)
.1.3.111.2.802.1.1.25.2.1.1.2
ieee8021BridgePEPortTypeThe operational mode of a port participating in Port Exension. The enumerated values are: pepCascade - the port is operating as a Cascade port pepUpstream - the port is operating as an Upstream port pepExtended - the port is operating as an Extended port
Enumeration
.1.3.111.2.802.1.1.25.2.1.1.3
ieee8021BridgePEPortUpstreamCSPAddressThe MAC address used for communication of the PE CSP protocol of the device connected to the upstream port of the Port Extender (which may be the Controlling Bridge or an upstream Port Extender). This provides the hierarchal relationship in a cascade of Port Extendersro
MacAddress (SNMPv2-TC)
.1.3.111.2.802.1.1.25.2.1.1.4
ieee8021BridgePEPortEcidThe default ECID assigend to this port and the port on the Port Extender to which this port corresponds.ro
IEEE802BridgePEEChannelIDTC
.1.3.111.2.802.1.1.25.2.1.1.5
ieee8021BridgePEPortNumberThe Port number on the of the Port on the Port Extender, or zero for the Upstream Port.ro
IEEE8021BridgePortNumberOrZero (IEEE8021-TC-MIB)
.1.3.111.2.802.1.1.25.2.1.1.6
ieee8021BridgePECounterDiscontinuityTimeThe value of sysUpTime on the most recent occasion at which any one or more of the counters in this conceptaul row suffered a discontinuity. The relevant counters are the specific instances associated with this conceptual row of any Counter32 or Counter64 object. If no such discontinuities have occurred since the last re-initialization of the local management subsystem, then this object contains a zero value.ro
TimeStamp (SNMPv2-TC)
.1.3.111.2.802.1.1.25.2.1.1.7
ieee8021BridgePEPortRxrqErrorsBridgeThe number of PE CSP flow control overflow errors that have occured for requests on the Bridge.ro
Counter64 UNITS "frames"
.1.3.111.2.802.1.1.25.2.1.1.8
ieee8021BridgePEPortRxrspErrorsBridgeThe number of PE CSP flow control overflow errors that have occured for responses on the Bridge.ro
Counter64 UNITS "octets"
.1.3.111.2.802.1.1.25.2.1.1.9
ieee8021BridgePEPortRxrqErrorsPEThe number of PE CSP flow control overflow errors that have occured for requests on the Port Extender.ro
Counter64 UNITS "frames"
.1.3.111.2.802.1.1.25.2.1.1.10
ieee8021BridgePEPortRxrspErrorsPEThe number of PE CSP flow control overflow errors that have occured for responses on the Port Extender.ro
Counter64 UNITS "octets"
.1.3.111.2.802.1.1.25.2.1.1.11
ieee8021BridgePEPCPIndicates whether the Port Exender supports modification of the priority code point table (true) or not (false).ro
TruthValue (SNMPv2-TC)
.1.3.111.2.802.1.1.25.2.1.1.12
ieee8021BridgePEROWIndicates whether the Port Extender supports rows in the PCP table in addition to the 8P0D row (true)or not (false).ro
TruthValue (SNMPv2-TC)
.1.3.111.2.802.1.1.25.2.1.1.13
ieee8021BridgePEDEIIndicates whether the Port Extender supports encoding of the Drop Eligible Indicatior (true) or not (false).ro
TruthValue (SNMPv2-TC)
.1.3.111.2.802.1.1.25.2.1.1.14
ieee8021BridgePECNIndicates whether the Port Extender supports Congestion Notification (true) or not (false).ro
TruthValue (SNMPv2-TC)
.1.3.111.2.802.1.1.25.2.1.1.15
ieee8021BridgePEPFCIndicates whether the Port Extender supports Priority-based flow control(true) or not (false).ro
TruthValue (SNMPv2-TC)
.1.3.111.2.802.1.1.25.2.1.1.16
ieee8021BridgePEExtPortEChannelsSupportedIndicates the number of Extended Port E-channels supported by the Port Extender.ro
Unsigned32
.1.3.111.2.802.1.1.25.2.1.1.17
ieee8021BridgePERemoteRepEChannelsSupportedIndicates the number of Remote Replication E-channels supported by the Port Extender.ro
Unsigned32
.1.3.111.2.802.1.1.25.2.1.1.18
ieee8021BridgePETCsSupportedIndicates the number of traffic clasees supported by the Port Extender.ro
Unsigned32
.1.3.111.2.802.1.1.25.2.1.1.19
ieee8021BridgePEUtVLANsSupportedIndicates the number of untagged VLANs supported by the Port Extender.ro
Unsigned32
.1.3.111.2.802.1.1.25.2.1.1.20
ieee8021BridgePERemoteReplicationTableA table that contains one row for each Remote Replication entry in the filtering database.
SEQUENCE OF Ieee8021BridgePERemoteReplicationEntry
.1.3.111.2.802.1.1.25.2.2
ieee8021BridgePERemoteReplicationEntryA list of Remote Replication objects.
Ieee8021BridgePERemoteReplicationEntry
.1.3.111.2.802.1.1.25.2.2.1
ieee8021BridgePERREcidThe ECID assigend to this Remote Replication filtering entry.
IEEE802BridgePEEChannelIDTC
.1.3.111.2.802.1.1.25.2.2.1.1
ieee8021BridgePERRPortMapThe list of ports to which a frame is to be replicated.ro
PortList (Q-BRIDGE-MIB)
.1.3.111.2.802.1.1.25.2.2.1.2
ieee8021BridgePEETSTableA table that contains per port information related to Enhanced Transmission Selection. A row is created in this table for any port on a Controlling Bridge that corresponds to a Cascade Port. These objects refer to the ETS configuration of the attached Upstream Port
SEQUENCE OF Ieee8021BridgePEETSEntry
.1.3.111.2.802.1.1.25.2.3
ieee8021BridgePEETSEntryA list of per Cascade Port ETS objects.
Ieee8021BridgePEETSEntry
.1.3.111.2.802.1.1.25.2.3.1
ieee8021BridgePEETSTrafficClassIndicates the traffic class to which this bandwidth applies
IEEE802BridgePETrafficClassValueTC
.1.3.111.2.802.1.1.25.2.3.1.1
ieee8021BridgePEETSTrafficSelectionAlgorthmInticates the Traffic Selection Algorthm assigned to this traffic classrw
IEEE802BridgePETrafficSelectionAlgorithmTC
.1.3.111.2.802.1.1.25.2.3.1.2
ieee8021BridgePEETSBandwidthIndicates the bandwidth assigned to this traffic class.rw
IEEE802BridgePETrafficClassBandwidthValue
.1.3.111.2.802.1.1.25.2.3.1.3
ieee8021BridgePEConformance
OBJECT IDENTIFIER
.1.3.111.2.802.1.1.25.3
ieee8021BridgePEGroups
OBJECT IDENTIFIER
.1.3.111.2.802.1.1.25.3.1
ieee8021BridgePECompliances
OBJECT IDENTIFIER
.1.3.111.2.802.1.1.25.3.2
IEEE8021-PE-MIB - SNMP MIB Reference | MIBs Explorer