Home/Catalog/GUDEADS-PDU8110-MIB

GUDEADS-PDU8110-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for GUDEADS-PDU8110-MIB.

Main OID:
gudeads.1.3.6.1.4.1.28507
37
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

37 total
Object Name
gudeads
MODULE-IDENTITY
.1.3.6.1.4.1.28507
gadsPDU8110
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23
events
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.0
pdu8110TempEvtSen1temperature limits exceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.23.0.1
pdu8110TempEvtSen2temperature limits exceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.23.0.2
pdu8110HygroEvtSen1hygro limits exceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.23.0.3
pdu8110HygroEvtSen2hygro limits exceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.23.0.4
pdu8110Objects
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.1
pdu8110CommonConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.1.1
pdu8110SNMPaccess
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.1.1.1
pdu8110TrapCtrl0 = off 1 = Ver. 1 2 = Ver. 2crw
Integer32
.1.3.6.1.4.1.28507.23.1.1.1.1
pdu8110TrapIPTablelist of all Trap receiver
SEQUENCE OF Epc8TrapIPEntry
.1.3.6.1.4.1.28507.23.1.1.1.2
pdu8110TrapIPEntryan entry containing management informations regarding the list of trap receivers
Epc8TrapIPEntry
.1.3.6.1.4.1.28507.23.1.1.1.2.1
pdu8110TrapIPIndexA unique value, greater than zero, for each receiver slot.
Integer32
.1.3.6.1.4.1.28507.23.1.1.1.2.1.1
pdu8110TrapAddrDNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot.rw
OCTET STRING
.1.3.6.1.4.1.28507.23.1.1.1.2.1.2
pdu8110DeviceConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.1.2
pdu8110IntActors
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.1.3
pdu8110ExtActors
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.1.4
pdu8110IntSensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.1.5
pdu8110PowerChan
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.1.5.1
pdu8110ActivePowerChanNumber of suppported Power Channels.ro
Unsigned32
.1.3.6.1.4.1.28507.23.1.5.1.1
pdu8110PowerTableAll available Channel Interfaces.
SEQUENCE OF Enc2102PowerEntry
.1.3.6.1.4.1.28507.23.1.5.1.2
pdu8110PowerEntryAn entry containing management information applicable to a particular Power Channel.
Enc2102PowerEntry
.1.3.6.1.4.1.28507.23.1.5.1.2.1
pdu8110PowerIndexIndex of Power Channel entries
Integer32 (1)
.1.3.6.1.4.1.28507.23.1.5.1.2.1.1
pdu8110ChanStatus0 = data not active, 1 = data validro
Integer32
.1.3.6.1.4.1.28507.23.1.5.1.2.1.2
pdu8110CurrentActual Curent on Power Channel.ro
Unsigned32 UNITS "mA"
.1.3.6.1.4.1.28507.23.1.5.1.2.1.5
pdu8110ExtSensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.1.6
pdu8110SensorTable
SEQUENCE OF Pdu8110SensorEntry
.1.3.6.1.4.1.28507.23.1.6.1
pdu8110SensorEntry
Pdu8110SensorEntry
.1.3.6.1.4.1.28507.23.1.6.1.1
pdu8110SensorIndex
Integer32
.1.3.6.1.4.1.28507.23.1.6.1.1.1
pdu8110TempSensoractual temperature, a value of -9999 indicates that data is not availablero
Integer32 UNITS "0.1 degree Celsius"
.1.3.6.1.4.1.28507.23.1.6.1.1.2
pdu8110HygroSensoractual humidity, a value of -9999 indicates that data is not availablero
Integer32 UNITS "0.1 percent humidity"
.1.3.6.1.4.1.28507.23.1.6.1.1.3
pdu8110Conf
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.2
pdu8110Groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.2.1
pdu8110BasicGroupBasic objects.
Unknown
.1.3.6.1.4.1.28507.23.2.1.1
pdu8110NotificationGroup
Unknown
.1.3.6.1.4.1.28507.23.2.1.2
pdu8110Compls
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.23.2.2
GUDEADS-PDU8110-MIB - SNMP MIB Reference | MIBs Explorer