GUDEADS-PDU8110-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for GUDEADS-PDU8110-MIB.
Main OID:
gudeads.1.3.6.1.4.1.28507
37
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
37 total| Object Name |
|---|
gudeads MODULE-IDENTITY .1.3.6.1.4.1.28507 |
gadsPDU8110 OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23 |
events OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.0 |
pdu8110TempEvtSen1temperature limits exceeded NOTIFICATION-TYPE .1.3.6.1.4.1.28507.23.0.1 |
pdu8110TempEvtSen2temperature limits exceeded NOTIFICATION-TYPE .1.3.6.1.4.1.28507.23.0.2 |
pdu8110HygroEvtSen1hygro limits exceeded NOTIFICATION-TYPE .1.3.6.1.4.1.28507.23.0.3 |
pdu8110HygroEvtSen2hygro limits exceeded NOTIFICATION-TYPE .1.3.6.1.4.1.28507.23.0.4 |
pdu8110Objects OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.1 |
pdu8110CommonConfig OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.1.1 |
pdu8110SNMPaccess OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.1.1.1 |
pdu8110TrapCtrl0 = off 1 = Ver. 1 2 = Ver. 2crw Integer32 .1.3.6.1.4.1.28507.23.1.1.1.1 |
pdu8110TrapIPTablelist of all Trap receiver SEQUENCE OF Epc8TrapIPEntry .1.3.6.1.4.1.28507.23.1.1.1.2 |
pdu8110TrapIPEntryan entry containing management informations regarding the list of trap receivers Epc8TrapIPEntry .1.3.6.1.4.1.28507.23.1.1.1.2.1 |
pdu8110TrapIPIndexA unique value, greater than zero, for each receiver slot. Integer32 .1.3.6.1.4.1.28507.23.1.1.1.2.1.1 |
pdu8110TrapAddrDNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot.rw OCTET STRING .1.3.6.1.4.1.28507.23.1.1.1.2.1.2 |
pdu8110DeviceConfig OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.1.2 |
pdu8110IntActors OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.1.3 |
pdu8110ExtActors OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.1.4 |
pdu8110IntSensors OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.1.5 |
pdu8110PowerChan OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.1.5.1 |
pdu8110ActivePowerChanNumber of suppported Power Channels.ro Unsigned32 .1.3.6.1.4.1.28507.23.1.5.1.1 |
pdu8110PowerTableAll available Channel Interfaces. SEQUENCE OF Enc2102PowerEntry .1.3.6.1.4.1.28507.23.1.5.1.2 |
pdu8110PowerEntryAn entry containing management information applicable to a particular Power Channel. Enc2102PowerEntry .1.3.6.1.4.1.28507.23.1.5.1.2.1 |
pdu8110PowerIndexIndex of Power Channel entries Integer32 (1) .1.3.6.1.4.1.28507.23.1.5.1.2.1.1 |
pdu8110ChanStatus0 = data not active, 1 = data validro Integer32 .1.3.6.1.4.1.28507.23.1.5.1.2.1.2 |
pdu8110CurrentActual Curent on Power Channel.ro Unsigned32 UNITS "mA" .1.3.6.1.4.1.28507.23.1.5.1.2.1.5 |
pdu8110ExtSensors OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.1.6 |
pdu8110SensorTable SEQUENCE OF Pdu8110SensorEntry .1.3.6.1.4.1.28507.23.1.6.1 |
pdu8110SensorEntry Pdu8110SensorEntry .1.3.6.1.4.1.28507.23.1.6.1.1 |
pdu8110SensorIndex Integer32 .1.3.6.1.4.1.28507.23.1.6.1.1.1 |
pdu8110TempSensoractual temperature, a value of -9999 indicates that data is not availablero Integer32 UNITS "0.1 degree Celsius" .1.3.6.1.4.1.28507.23.1.6.1.1.2 |
pdu8110HygroSensoractual humidity, a value of -9999 indicates that data is not availablero Integer32 UNITS "0.1 percent humidity" .1.3.6.1.4.1.28507.23.1.6.1.1.3 |
pdu8110Conf OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.2 |
pdu8110Groups OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.2.1 |
pdu8110BasicGroupBasic objects. Unknown .1.3.6.1.4.1.28507.23.2.1.1 |
pdu8110NotificationGroup Unknown .1.3.6.1.4.1.28507.23.2.1.2 |
pdu8110Compls OBJECT IDENTIFIER .1.3.6.1.4.1.28507.23.2.2 |