Home/Catalog/GUDEADS-ESB7213-MIB

GUDEADS-ESB7213-MIB

AI MIB Summary

The GUDEADS-ESB7213-MIB module facilitates SNMP-based monitoring and management of the Expert Power Control 7213 hardware platform, specifically exposing telemetry for power supply status, voltage levels, current draw, and thermal sensor readings. This module enables network administrators to track real-time power consumption metrics and fault conditions on the ESB7213 chassis to ensure electrical stability and prevent hardware failure.

Expert Power Control 7213 MIB
Main OID:
gudeads.1.3.6.1.4.1.28507
52
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

52 total
Object Name
gudeadsExpert Power Control 7213 MIB
MODULE-IDENTITY
.1.3.6.1.4.1.28507
gadsESB7213
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66
esb7213Objects
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.1
esb7213CommonConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.1.1
esb7213SNMPaccess
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.1.1.1
esb7213TrapCtrl0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3rw
Integer32
.1.3.6.1.4.1.28507.66.1.1.1.1
esb7213TrapIPTablelist of all Trap receiver
SEQUENCE OF Esb7213TrapIPEntry
.1.3.6.1.4.1.28507.66.1.1.1.2
esb7213TrapIPEntryan entry containing management informations regarding the list of trap receivers
Esb7213TrapIPEntry
.1.3.6.1.4.1.28507.66.1.1.1.2.1
esb7213TrapIPIndexA unique value, greater than zero, for each receiver slot.ro
Integer32
.1.3.6.1.4.1.28507.66.1.1.1.2.1.1
esb7213TrapAddrDNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot.rw
OCTET STRING
.1.3.6.1.4.1.28507.66.1.1.1.2.1.2
esb7213DeviceConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.1.2
esb7213IntActors
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.1.3
esb7213ExtActors
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.1.4
esb7213IntSensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.1.5
esb7213POEsignals POE availabilityro
Integer32
.1.3.6.1.4.1.28507.66.1.5.10
esb7213NTPClient
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.1.5.15
esb7213NTPTimeValidShow if valid Time is receivedro
Enumeration
.1.3.6.1.4.1.28507.66.1.5.15.1
esb7213NTPUnixTimeshow received NTP time as unixtime (secs since 1 January 1970)ro
Unsigned32 UNITS "s"
.1.3.6.1.4.1.28507.66.1.5.15.2
esb7213NTPLastValidTimestampshow seconds since last valid NTP timestamp receivedro
Unsigned32 UNITS "s"
.1.3.6.1.4.1.28507.66.1.5.15.3
esb7213ExtSensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.1.6
esb7213SensorTable
SEQUENCE OF Esb7213SensorEntry
.1.3.6.1.4.1.28507.66.1.6.1
esb7213SensorEntry
Esb7213SensorEntry
.1.3.6.1.4.1.28507.66.1.6.1.1
esb7213SensorIndexro
Integer32
.1.3.6.1.4.1.28507.66.1.6.1.1.1
esb7213TempSensoractual temperaturero
Integer32 UNITS "0.1 degree Celsius"
.1.3.6.1.4.1.28507.66.1.6.1.1.2
esb7213HygroSensoractual humidityro
Integer32 UNITS "0.1 percent humidity"
.1.3.6.1.4.1.28507.66.1.6.1.1.3
esb7213InputSensorlogical state of input sensorro
Enumeration
.1.3.6.1.4.1.28507.66.1.6.1.1.4
esb7213AirPressureactual air pressurero
Integer32 UNITS "1 hPA (hectopascal) ~ 1 milibar"
.1.3.6.1.4.1.28507.66.1.6.1.1.5
esb7213DewPointdew point for actual temperature and humidityro
Integer32 UNITS "0.1 degree Celsius"
.1.3.6.1.4.1.28507.66.1.6.1.1.6
esb7213DewPointDiffdifference between dew point and actual temperature (Temp - DewPoint)ro
Integer32 UNITS "0.1 degree Celsius"
.1.3.6.1.4.1.28507.66.1.6.1.1.7
esb7213ExtSensorNameA textual string containing name of a external Sensorrw
OCTET STRING
.1.3.6.1.4.1.28507.66.1.6.1.1.32
esb7213ExtInputs
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.1.6.2
esb7213ExtActiveInputsNumber of suppported Input Channels.ro
Unsigned32
.1.3.6.1.4.1.28507.66.1.6.2.1
esb7213ExtInputTable
SEQUENCE OF Esb7213ExtInputEntry
.1.3.6.1.4.1.28507.66.1.6.2.2
esb7213ExtInputEntry
Esb7213ExtInputEntry
.1.3.6.1.4.1.28507.66.1.6.2.2.1
esb7213ExtInputIndexro
Unsigned32
.1.3.6.1.4.1.28507.66.1.6.2.2.1.1
esb7213ExtInputInput state of devicero
Enumeration
.1.3.6.1.4.1.28507.66.1.6.2.2.1.2
esb7213ExtInputNameA textual string containing name of the Inputrw
OCTET STRING
.1.3.6.1.4.1.28507.66.1.6.2.2.1.32
esb7213ExtInputPortNumNumber of external Sensor Port when value greater zero, else device built-in Input.ro
Integer32
.1.3.6.1.4.1.28507.66.1.6.2.2.1.33
esb7213ExtInputBlockIndexEither index of device built-in Input, or index of Input in external sensor.ro
Integer32
.1.3.6.1.4.1.28507.66.1.6.2.2.1.34
esb7213Conf
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.2
esb7213Groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.2.1
esb7213BasicGroupBasic objects.
Unknown
.1.3.6.1.4.1.28507.66.2.1.1
esb7213NotificationGroup
Unknown
.1.3.6.1.4.1.28507.66.2.1.2
esb7213Compls
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.2.2
events
OBJECT IDENTIFIER
.1.3.6.1.4.1.28507.66.3
esb7213TempEvtSentemperature limits exceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.66.3.1
esb7213HygroEvtSenhygro limits exceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.66.3.2
esb7213InputEvtSenchange of logical input sensor state
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.66.3.3
esb7213AirPressureEvtSenAir Pressure limits exceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.66.3.4
esb7213DewPtDiffEvtSenDew Point Difference limits exceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.66.3.5
esb7213POEEvtPower over Ethernet changed
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.66.3.6
esb7213ExtInputEvtChange of external sensor input.
NOTIFICATION-TYPE
.1.3.6.1.4.1.28507.66.3.25
GUDEADS-ESB7213-MIB - SNMP MIB Reference | MIBs Explorer