GUDEADS-EPC2X6-MIB
Standard SNMP MIB module defining data structures for GUDEADS-EPC2X6-MIB.
Imported Objects
Objects
43 total| Object Name |
|---|
gudeads MODULE-IDENTITY .1.3.6.1.4.1.28507 |
events OBJECT IDENTIFIER .1.3.6.1.4.1.28507.0 |
epc2x6witchEvt1Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.1 |
epc2x6witchEvt2Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.2 |
epc2x6witchEvt3Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.3 |
epc2x6witchEvt4Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.4 |
epc2x6witchEvt5Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.5 |
epc2x6witchEvt6Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.6 |
epc2x6witchEvt7Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.7 |
epc2x6witchEvt8Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.8 |
epc2x6witchEvt9Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.9 |
epc2x6witchEvt10Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.10 |
epc2x6witchEvt11Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.11 |
epc2x6witchEvt12Event is triggered when NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.12 |
epc2x6FuseEvt NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.13 |
epc2x6TempEvtchange of temperature NOTIFICATION-TYPE .1.3.6.1.4.1.28507.0.14 |
gadsEPC2x6 OBJECT IDENTIFIER .1.3.6.1.4.1.28507.6 |
epc2x6Objects OBJECT IDENTIFIER .1.3.6.1.4.1.28507.6.1 |
epc2x6SNMPaccess OBJECT IDENTIFIER .1.3.6.1.4.1.28507.6.1.1 |
epc2x6TrapCtrl0 = off 1 = Ver. 1 2 = Ver. 2crw Integer32 .1.3.6.1.4.1.28507.6.1.1.1 |
epc2x6TrapIPTablelist of all Trap receiver SEQUENCE OF Epc2x6TrapIPEntry .1.3.6.1.4.1.28507.6.1.1.2 |
epc2x6TrapIPEntryan entry containing management informations regarding the list of trap receivers Epc2x6TrapIPEntry .1.3.6.1.4.1.28507.6.1.1.2.1 |
epc2x6TrapIPIndexA unique value, greater than zero, for each receiver slot. Integer32 .1.3.6.1.4.1.28507.6.1.1.2.1.1 |
epc2x6TrapIPAddrIP Address specifying one Trap receiver slot. A value of '00000000'H disables this slot.rw IpAddress .1.3.6.1.4.1.28507.6.1.1.2.1.2 |
epc2x6TrapIPPortIP Port specifying one Trap receiver slot. A value of 0 disables this slot.rw Integer32 .1.3.6.1.4.1.28507.6.1.1.2.1.3 |
epc2x6powerports OBJECT IDENTIFIER .1.3.6.1.4.1.28507.6.1.2 |
epc2x6portNumberThe number of PowerPortsro Integer32 .1.3.6.1.4.1.28507.6.1.2.1 |
epc2x6portTablelist of all EPC Powerports SEQUENCE OF Epc2x6portEntry .1.3.6.1.4.1.28507.6.1.2.2 |
epc2x6portEntryAn entry containing management information applicable to a particular powerport. Epc2x6portEntry .1.3.6.1.4.1.28507.6.1.2.2.1 |
epc2x6PortIndexA unique value, greater than zero, for each PowerPort. Integer32 .1.3.6.1.4.1.28507.6.1.2.2.1.1 |
epc2x6PortNameA textual string containing name of a PowerPort.ro OCTET STRING .1.3.6.1.4.1.28507.6.1.2.2.1.2 |
epc2x6PortStatecurrent state a PowerPortrw Enumeration .1.3.6.1.4.1.28507.6.1.2.2.1.3 |
epc2x6PortSwitchCountThe total number of switch actions ocurred on a PowerPort. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here.ro Counter32 .1.3.6.1.4.1.28507.6.1.2.2.1.4 |
epc2x6PortStartupModeset Mode of startup sequence (off, on , remember last state)rw Enumeration .1.3.6.1.4.1.28507.6.1.2.2.1.5 |
epc2x6PortStartupDelayDelay in sec for startup actionrw Integer32 UNITS "seconds" .1.3.6.1.4.1.28507.6.1.2.2.1.6 |
epc2x6PortRepowerTimeDelay in sec for repower port after switching offrw Integer32 .1.3.6.1.4.1.28507.6.1.2.2.1.7 |
epc2x6portFusesBit State of Fuses (Bit 0 = Fuse1, Bit 1 = Fuse2)ro Integer32 .1.3.6.1.4.1.28507.6.1.2.3 |
epc2x6Temperatureactual Temperature, if sensor is not supported '9998', not connected '9999' is given back as resultro Integer32 UNITS "10th of degree Celsius" .1.3.6.1.4.1.28507.6.1.3 |
epc2x6Conf OBJECT IDENTIFIER .1.3.6.1.4.1.28507.6.3 |
epc2x6Groups OBJECT IDENTIFIER .1.3.6.1.4.1.28507.6.3.1 |
epc2x6BasicGroupBasic objects. Unknown .1.3.6.1.4.1.28507.6.3.1.1 |
epc2x6NotificationGroup Unknown .1.3.6.1.4.1.28507.6.3.1.2 |
epc2x6Compls OBJECT IDENTIFIER .1.3.6.1.4.1.28507.6.3.2 |
More MIBs from Gude Analog- und Digitalsysteme GmbH
Browse all Gude Analog- und Digitalsysteme GmbHMIBs →The GUDEADS-ESB7214-MIB module facilitates the monitoring and management of the Expert Power Control 7214 power distribution unit, specifically exposing metrics for input/output voltage, current, power consumption, temperature sensors, and relay status via SNMP.
The GUDEADS-ESB7213-MIB module facilitates SNMP-based monitoring and management of the Expert Power Control 7213 hardware platform, specifically exposing telemetry for power supply status, voltage levels, current draw, and thermal sensor readings. This module enables network administrators to track real-time power consumption metrics and fault conditions on the ESB7213 chassis to ensure electrical stability and prevent hardware failure.
Standard SNMP MIB module defining data structures for GUDEADS-EPC8X-MIB.
Standard SNMP MIB module defining data structures for GUDEADS-PDU8310-MIB.
Standard SNMP MIB module defining data structures for GUDEADS-PDU8110-MIB.
Standard SNMP MIB module defining data structures for GUDEADS-ETS-MIB.