G6-SFP-MIB
AI MIB Summary
The G6-SFP-MIB provides vendor-specific SNMP management capabilities for Microsens Generation 6 Ethernet switches, specifically exposing optical transceiver (SFP) parameters such as temperature, voltage, bias current, and transmit/receive optical power levels. This module enables granular monitoring of physical layer health and link integrity for SFP modules installed in these switch platforms.
Microsens private MIB for Generation 6 Ethernet Switches
Main OID:
device.1.3.6.1.4.1.3181.10.6.1
37
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
37 total| Object Name |
|---|
deviceMicrosens private MIB for Generation 6 Ethernet Switches MODULE-IDENTITY .1.3.6.1.4.1.3181.10.6.1 |
sfp OBJECT IDENTIFIER .1.3.6.1.4.1.3181.10.6.1.34 |
configTableThese setting apply to each SFP in the system. SEQUENCE OF ConfigEntry .1.3.6.1.4.1.3181.10.6.1.34.1 |
configEntry ConfigEntry .1.3.6.1.4.1.3181.10.6.1.34.1.1 |
configIndexAutomatically generated INTEGER (0) .1.3.6.1.4.1.3181.10.6.1.34.1.1.1 |
configLossOfSignalEventWhen enabled a loss of optical signal or the return of the signal will create an event.rw Enumeration .1.3.6.1.4.1.3181.10.6.1.34.1.1.2 |
configOpticalDeltaDetectAn optical receive power level change of more than delta_threshold between two successive read cycles generates an event.rw Enumeration .1.3.6.1.4.1.3181.10.6.1.34.1.1.3 |
configDeltaThresholdDefines the dB difference required to trigger an event. Only 1 dB steps are permitted. A value of 0 detects any change. This setting is only for testing. Recommended value: 2.rw Integer32 .1.3.6.1.4.1.3181.10.6.1.34.1.1.4 |
informationTableThis table displays data which are read from the inserted SFPs. SEQUENCE OF InformationEntry .1.3.6.1.4.1.3181.10.6.1.34.100 |
informationEntry InformationEntry .1.3.6.1.4.1.3181.10.6.1.34.100.1 |
informationPortIndexAutomatically generated INTEGER .1.3.6.1.4.1.3181.10.6.1.34.100.1.1 |
informationPortIndicates the physical port in which this SFP is inserted.ro OCTET STRING .1.3.6.1.4.1.3181.10.6.1.34.100.1.2 |
informationLocationTextual description of SFP location.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.3 |
informationStatusShould indicate OK. LOSS_OF_SIGNAL is shown when the optical receive power level is below the critical lower limit.ro Bits .1.3.6.1.4.1.3181.10.6.1.34.100.1.4 |
informationTypeThis parameter shows which type of optics are installedro Enumeration .1.3.6.1.4.1.3181.10.6.1.34.100.1.5 |
informationConnectorShows which connector is used with this SFP.ro Enumeration .1.3.6.1.4.1.3181.10.6.1.34.100.1.6 |
informationWavelengthNominal wavelength if this SFP. May also indicate ITU channel for DWDM optics.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.7 |
informationTxTechnologyDistinguishes between multimode and single mode SFP. For DWDM SFP more details including grid are shown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.8 |
informationRxTechnologyDistinguishes between normal PIN receivers and more sensitive APD receivers.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.9 |
informationNominalBitrateNominal bitrate rounded to nearest 100Mbit. Usually the SFP can be operated at lower speed as well.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.10 |
informationManufacturerShows the manufacturer of this SFP.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.11 |
informationPartNumberShows the part number of this SFP. This will differ from the MICROSENS order code unless also MICROSENS is indicated as manufacturer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.12 |
informationRevisionInternal revision code of this SFP.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.13 |
informationSerialNumberSerial number of the SFP.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.14 |
informationMfgDateCodeManufacturing date code.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.15 |
informationWarningsro Bits .1.3.6.1.4.1.3181.10.6.1.34.100.1.16 |
informationAlarmsro Bits .1.3.6.1.4.1.3181.10.6.1.34.100.1.17 |
informationTxPowerIndicates the optical output in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.18 |
informationRxPowerIndicates the optical input in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.19 |
informationTemperatureDisplays the temperature inside the SFP. This is usually higher than the system temperature.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.20 |
informationMaxLength9UmDisplays nominal maximum reach of this SFP on a standard single mode fiber.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.21 |
informationMaxLength50UmDisplays nominal maximum reach of this SFP on a 50 micro meter multimode fiber.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.22 |
informationMaxLength62UmDisplays nominal maximum reach of this SFP on a 62.5 micro meter multimode fiber.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.23 |
informationMaxLengthCopperDisplays nominal maximum reach of this SFP on a copper cable. Only applies to electrical SFP.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.24 |
informationTuningRangeFor wavelength tunable optics additional details are shown here.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.25 |
informationPowerConsumptionTypical power consumption values are shown if available from the interface.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.26 |
informationAdditionalInformationSome special SFP can supply additional measurement data. For example OTDR reflection data can be listed here.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.27 |