Home/Catalog/G6-SFP-MIB

G6-SFP-MIB

AI MIB Summary

The G6-SFP-MIB provides vendor-specific SNMP management capabilities for Microsens Generation 6 Ethernet switches, specifically exposing optical transceiver (SFP) parameters such as temperature, voltage, bias current, and transmit/receive optical power levels. This module enables granular monitoring of physical layer health and link integrity for SFP modules installed in these switch platforms.

Microsens private MIB for Generation 6 Ethernet Switches
Main OID:
device.1.3.6.1.4.1.3181.10.6.1
37
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

37 total
Object Name
deviceMicrosens private MIB for Generation 6 Ethernet Switches
MODULE-IDENTITY
.1.3.6.1.4.1.3181.10.6.1
sfp
OBJECT IDENTIFIER
.1.3.6.1.4.1.3181.10.6.1.34
configTableThese setting apply to each SFP in the system.
SEQUENCE OF ConfigEntry
.1.3.6.1.4.1.3181.10.6.1.34.1
configEntry
ConfigEntry
.1.3.6.1.4.1.3181.10.6.1.34.1.1
configIndexAutomatically generated
INTEGER (0)
.1.3.6.1.4.1.3181.10.6.1.34.1.1.1
configLossOfSignalEventWhen enabled a loss of optical signal or the return of the signal will create an event.rw
Enumeration
.1.3.6.1.4.1.3181.10.6.1.34.1.1.2
configOpticalDeltaDetectAn optical receive power level change of more than delta_threshold between two successive read cycles generates an event.rw
Enumeration
.1.3.6.1.4.1.3181.10.6.1.34.1.1.3
configDeltaThresholdDefines the dB difference required to trigger an event. Only 1 dB steps are permitted. A value of 0 detects any change. This setting is only for testing. Recommended value: 2.rw
Integer32
.1.3.6.1.4.1.3181.10.6.1.34.1.1.4
informationTableThis table displays data which are read from the inserted SFPs.
SEQUENCE OF InformationEntry
.1.3.6.1.4.1.3181.10.6.1.34.100
informationEntry
InformationEntry
.1.3.6.1.4.1.3181.10.6.1.34.100.1
informationPortIndexAutomatically generated
INTEGER
.1.3.6.1.4.1.3181.10.6.1.34.100.1.1
informationPortIndicates the physical port in which this SFP is inserted.ro
OCTET STRING
.1.3.6.1.4.1.3181.10.6.1.34.100.1.2
informationLocationTextual description of SFP location.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.3
informationStatusShould indicate OK. LOSS_OF_SIGNAL is shown when the optical receive power level is below the critical lower limit.ro
Bits
.1.3.6.1.4.1.3181.10.6.1.34.100.1.4
informationTypeThis parameter shows which type of optics are installedro
Enumeration
.1.3.6.1.4.1.3181.10.6.1.34.100.1.5
informationConnectorShows which connector is used with this SFP.ro
Enumeration
.1.3.6.1.4.1.3181.10.6.1.34.100.1.6
informationWavelengthNominal wavelength if this SFP. May also indicate ITU channel for DWDM optics.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.7
informationTxTechnologyDistinguishes between multimode and single mode SFP. For DWDM SFP more details including grid are shown.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.8
informationRxTechnologyDistinguishes between normal PIN receivers and more sensitive APD receivers.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.9
informationNominalBitrateNominal bitrate rounded to nearest 100Mbit. Usually the SFP can be operated at lower speed as well.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.10
informationManufacturerShows the manufacturer of this SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.11
informationPartNumberShows the part number of this SFP. This will differ from the MICROSENS order code unless also MICROSENS is indicated as manufacturer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.12
informationRevisionInternal revision code of this SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.13
informationSerialNumberSerial number of the SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.14
informationMfgDateCodeManufacturing date code.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.15
informationWarningsro
Bits
.1.3.6.1.4.1.3181.10.6.1.34.100.1.16
informationAlarmsro
Bits
.1.3.6.1.4.1.3181.10.6.1.34.100.1.17
informationTxPowerIndicates the optical output in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.18
informationRxPowerIndicates the optical input in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.19
informationTemperatureDisplays the temperature inside the SFP. This is usually higher than the system temperature.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.20
informationMaxLength9UmDisplays nominal maximum reach of this SFP on a standard single mode fiber.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.21
informationMaxLength50UmDisplays nominal maximum reach of this SFP on a 50 micro meter multimode fiber.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.22
informationMaxLength62UmDisplays nominal maximum reach of this SFP on a 62.5 micro meter multimode fiber.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.23
informationMaxLengthCopperDisplays nominal maximum reach of this SFP on a copper cable. Only applies to electrical SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.24
informationTuningRangeFor wavelength tunable optics additional details are shown here.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.25
informationPowerConsumptionTypical power consumption values are shown if available from the interface.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.26
informationAdditionalInformationSome special SFP can supply additional measurement data. For example OTDR reflection data can be listed here.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3181.10.6.1.34.100.1.27
G6-SFP-MIB - SNMP MIB Reference | MIBs Explorer