G6-SFP-MIB
The G6-SFP-MIB provides vendor-specific SNMP management capabilities for Microsens Generation 6 Ethernet switches, specifically exposing optical transceiver (SFP) parameters such as temperature, voltage, bias current, and transmit/receive optical power levels. This module enables granular monitoring of physical layer health and link integrity for SFP modules installed in these switch platforms.
Imported Objects
Objects
37 total| Object Name |
|---|
deviceMicrosens private MIB for Generation 6 Ethernet Switches MODULE-IDENTITY .1.3.6.1.4.1.3181.10.6.1 |
sfp OBJECT IDENTIFIER .1.3.6.1.4.1.3181.10.6.1.34 |
configTableThese setting apply to each SFP in the system. SEQUENCE OF ConfigEntry .1.3.6.1.4.1.3181.10.6.1.34.1 |
configEntry ConfigEntry .1.3.6.1.4.1.3181.10.6.1.34.1.1 |
configIndexAutomatically generated INTEGER (0) .1.3.6.1.4.1.3181.10.6.1.34.1.1.1 |
configLossOfSignalEventWhen enabled a loss of optical signal or the return of the signal will create an event.rw Enumeration .1.3.6.1.4.1.3181.10.6.1.34.1.1.2 |
configOpticalDeltaDetectAn optical receive power level change of more than delta_threshold between two successive read cycles generates an event.rw Enumeration .1.3.6.1.4.1.3181.10.6.1.34.1.1.3 |
configDeltaThresholdDefines the dB difference required to trigger an event. Only 1 dB steps are permitted. A value of 0 detects any change. This setting is only for testing. Recommended value: 2.rw Integer32 .1.3.6.1.4.1.3181.10.6.1.34.1.1.4 |
informationTableThis table displays data which are read from the inserted SFPs. SEQUENCE OF InformationEntry .1.3.6.1.4.1.3181.10.6.1.34.100 |
informationEntry InformationEntry .1.3.6.1.4.1.3181.10.6.1.34.100.1 |
informationPortIndexAutomatically generated INTEGER .1.3.6.1.4.1.3181.10.6.1.34.100.1.1 |
informationPortIndicates the physical port in which this SFP is inserted.ro OCTET STRING .1.3.6.1.4.1.3181.10.6.1.34.100.1.2 |
informationLocationTextual description of SFP location.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.3 |
informationStatusShould indicate OK. LOSS_OF_SIGNAL is shown when the optical receive power level is below the critical lower limit.ro Bits .1.3.6.1.4.1.3181.10.6.1.34.100.1.4 |
informationTypeThis parameter shows which type of optics are installedro Enumeration .1.3.6.1.4.1.3181.10.6.1.34.100.1.5 |
informationConnectorShows which connector is used with this SFP.ro Enumeration .1.3.6.1.4.1.3181.10.6.1.34.100.1.6 |
informationWavelengthNominal wavelength if this SFP. May also indicate ITU channel for DWDM optics.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.7 |
informationTxTechnologyDistinguishes between multimode and single mode SFP. For DWDM SFP more details including grid are shown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.8 |
informationRxTechnologyDistinguishes between normal PIN receivers and more sensitive APD receivers.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.9 |
informationNominalBitrateNominal bitrate rounded to nearest 100Mbit. Usually the SFP can be operated at lower speed as well.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.10 |
informationManufacturerShows the manufacturer of this SFP.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.11 |
informationPartNumberShows the part number of this SFP. This will differ from the MICROSENS order code unless also MICROSENS is indicated as manufacturer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.12 |
informationRevisionInternal revision code of this SFP.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.13 |
informationSerialNumberSerial number of the SFP.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.14 |
informationMfgDateCodeManufacturing date code.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.15 |
informationWarningsro Bits .1.3.6.1.4.1.3181.10.6.1.34.100.1.16 |
informationAlarmsro Bits .1.3.6.1.4.1.3181.10.6.1.34.100.1.17 |
informationTxPowerIndicates the optical output in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.18 |
informationRxPowerIndicates the optical input in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.19 |
informationTemperatureDisplays the temperature inside the SFP. This is usually higher than the system temperature.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.20 |
informationMaxLength9UmDisplays nominal maximum reach of this SFP on a standard single mode fiber.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.21 |
informationMaxLength50UmDisplays nominal maximum reach of this SFP on a 50 micro meter multimode fiber.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.22 |
informationMaxLength62UmDisplays nominal maximum reach of this SFP on a 62.5 micro meter multimode fiber.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.23 |
informationMaxLengthCopperDisplays nominal maximum reach of this SFP on a copper cable. Only applies to electrical SFP.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.24 |
informationTuningRangeFor wavelength tunable optics additional details are shown here.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.25 |
informationPowerConsumptionTypical power consumption values are shown if available from the interface.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.26 |
informationAdditionalInformationSome special SFP can supply additional measurement data. For example OTDR reflection data can be listed here.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3181.10.6.1.34.100.1.27 |
More MIBs from Microsens
Browse all MicrosensMIBs →The MS-SWITCH30-MIB module provides SNMP-based management capabilities for Microsoft Switch 30 series hardware, enabling the monitoring of interface status, port statistics, and device operational parameters.
The G6-HARDWARE-MIB provides vendor-specific SNMP access to monitor physical layer telemetry and hardware status indicators, including temperature, fan speeds, and power supply states, for Microsens Generation 6 Ethernet switches. This module enables granular fault detection and environmental monitoring by exposing hardware component health metrics not covered by standard IETF MIBs.
Standard SNMP MIB module defining data structures for MICROSENS-CWDM8-MIB.
The RING-MIB module facilitates the monitoring and management of Coriolis ring network topologies, specifically tracking ring port states, topology changes, and loop prevention mechanisms within Coriolis switching hardware.
The G6-RING-MIB facilitates the monitoring and management of Generation 6 Microsens Ethernet switches, specifically enabling the tracking of ring topology status, port states, and redundancy protocol events to ensure network resilience.
The G6-WIFI-MIB module provides vendor-specific SNMP extensions for Microsens Generation 6 Ethernet Switches to monitor Wi-Fi interface states, client association counts, signal strength metrics, and radio channel utilization. This private MIB enables granular visibility into wireless subsystem performance and connectivity anomalies on Microsens hardware that are not covered by standard IETF MIBs.