MICROSENS-CWDM8-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for MICROSENS-CWDM8-MIB.
113
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
113 total| Object Name |
|---|
microsens OBJECT IDENTIFIER .1.3.6.1.4.1.3181 |
cwdm OBJECT IDENTIFIER .1.3.6.1.4.1.3181.6 |
eightChannelCwdm OBJECT IDENTIFIER .1.3.6.1.4.1.3181.6.4 |
minorAlarmRelayTrapTrap indicating a change in the minor alarm relay status. NOTIFICATION-TYPE .1.3.6.1.4.1.3181.6.4.0.0 |
majorAlarmRelayTrapTrap indicating a change in the major alarm relay status. NOTIFICATION-TYPE .1.3.6.1.4.1.3181.6.4.0.1 |
devicePowerSupplyTrapTrap indicating a change in the power-supply redundancy status. NOTIFICATION-TYPE .1.3.6.1.4.1.3181.6.4.0.2 |
deviceTemperatureAlarmTrapTrap indicating a device temperature alarm event has occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.3181.6.4.0.3 |
deviceTemperatureShutdownTrapTrap indicating a device temperature shutdown event has occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.3181.6.4.0.4 |
fanAlarmTrapTrap indicating a fan alarm in a power supply module. NOTIFICATION-TYPE .1.3.6.1.4.1.3181.6.4.0.5 |
portLocalLinkChangeTrapTrap indicating that a port's local link status has changed. The port is identified by the portId variable. NOTIFICATION-TYPE .1.3.6.1.4.1.3181.6.4.0.6 |
portLineLinkChangeTrapTrap indicating that a port's line link status has changed. The port is identified by the portId variable. NOTIFICATION-TYPE .1.3.6.1.4.1.3181.6.4.0.7 |
deviceTableThis table describes the device-status of the CWDM-system. SEQUENCE OF DeviceList .1.3.6.1.4.1.3181.6.4.1 |
deviceTableEntryAn entry in the port table. DeviceList .1.3.6.1.4.1.3181.6.4.1.1 |
deviceIdThis entry describes the device id.ro INTEGER .1.3.6.1.4.1.3181.6.4.1.1.1 |
deviceArtNoThis entry describes the article number of the device.ro DisplayString .1.3.6.1.4.1.3181.6.4.1.1.2 |
deviceSerNoThis entry describes the serial number of the device.ro DisplayString .1.3.6.1.4.1.3181.6.4.1.1.3 |
deviceDescThis entry provides a detailed description of the device.ro DisplayString .1.3.6.1.4.1.3181.6.4.1.1.4 |
deviceTemperatureThis entry describes the temperature of the device in degree centigrade.ro Enumeration .1.3.6.1.4.1.3181.6.4.1.1.5 |
deviceTempAlarmThresholdThis entry describes the current temperature-alarm threshold value of the device in degree centigrade.ro Enumeration .1.3.6.1.4.1.3181.6.4.1.1.6 |
deviceTempAlarmThis entry describes if a temperature-alarm condition has occurred or not.ro Enumeration .1.3.6.1.4.1.3181.6.4.1.1.7 |
deviceTempShutdownThis entry describes if a temperature-shutdown condition has occurred or not.ro Enumeration .1.3.6.1.4.1.3181.6.4.1.1.8 |
deviceTrPowerFailureAlarmThis entry describes if a transceiver-board power-supply-alarm condition has occurred or not.ro Enumeration .1.3.6.1.4.1.3181.6.4.1.1.9 |
deviceMinorAlarmThis entry describes if a minor-alarm condition has occurred or not.ro Enumeration .1.3.6.1.4.1.3181.6.4.1.1.10 |
deviceMajorAlarmThis entry describes if a major-alarm condition has occurred or not.ro Enumeration .1.3.6.1.4.1.3181.6.4.1.1.11 |
portTableThis table describes the port-status of the CWDM-system. SEQUENCE OF PortList .1.3.6.1.4.1.3181.6.4.2 |
portTableEntryAn entry in the port table. PortList .1.3.6.1.4.1.3181.6.4.2.1 |
portIdThis entry describes the port id.ro INTEGER .1.3.6.1.4.1.3181.6.4.2.1.1 |
portChannelEnabledThis entry describes the channel's status. A value of 1 indicates that the channel is enabled, a value of 0 indicates that the channel is not enabled.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.2 |
portLinkThroughLocalLineThis entry describes the local-line link-through-status of the port.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.3 |
portLinkThroughLineLocalThis entry describes the line-local link-through-status of the port.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.4 |
portLocalModuleInstalledThis entry describes if a local transceiver module is installed or not.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.5 |
portLineModuleInstalledThis entry describes if a line transceiver module is installed or not.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.6 |
portLocalLinkThis entry describes the port's local link status.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.7 |
portLineLinkThis entry describes the port's line link status.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.8 |
portLocalTxFaultThis entry describes the port's local-tx-fault status.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.9 |
portLineTxFaultThis entry describes the port's line-tx-fault status.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.10 |
portLocalPowerFaultThis entry describes the port's local-power-fault status.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.11 |
portLinePowerFaultThis entry describes the port's line-power-fault status.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.12 |
portRateSelectThis entry describes the port's local data rate. A value of 1 describes full data rate, a value of 0 describes reduced data rate.ro Enumeration .1.3.6.1.4.1.3181.6.4.2.1.13 |
localModuleTableThis table describes the local module status of the CWDM-system. SEQUENCE OF LocalModuleList .1.3.6.1.4.1.3181.6.4.3 |
localModuleTableEntryAn entry in the local module table. LocalModuleList .1.3.6.1.4.1.3181.6.4.3.1 |
localModuleIdThis entry describes the local module id.ro INTEGER .1.3.6.1.4.1.3181.6.4.3.1.1 |
localModuleConnectorThis entry describes the connector-type of the port.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.2 |
localModuleTrCodeSonetThis entry describes the SONET compliance of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.3 |
localModuleTrCodeGigabitThis entry describes the Gigabit Ethernet compliance of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.4 |
localModuleTrCodeFbLinkLengthThis entry describes the fibre channel link length of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.5 |
localModuleTrCodeFbTrTechThis entry describes the fibre channel transmitter technology of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.6 |
localModuleTrCodeFbTrMediaThis entry describes the fibre channel transmission media of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.7 |
localModuleTrCodeFbSpeedThis entry describes the fibre channel speed of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.8 |
localModuleBrNominalThis entry describes the nominal bit rate, specified in units of 100 Megabits per second.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.9 |
localModuleLength9kmThis entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of kilometers. A value of 255 means that the transceiver supports a link length greater than 254 km. A value of zero means that the transceiver does not support single-mode fibers.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.10 |
localModuleLength9mThis entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of 100 meters. A value of 255 means that the transceiver supports a link length greater than 25.4 km. A value of zero means that the transceiver does not support single-mode fibers.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.11 |
localModuleLength50This entry describes the link length supported by the transceiver using 50 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 50 micron multi-mode fibers.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.12 |
localModuleLength62This entry describes the link length supported by the transceiver using 62.5 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 62.5 micron multi-mode fibers.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.13 |
localModuleLengthCopperThis entry describes the link length supported by the transceiver using copper cables. The value is in units of 1 meter. A value of 255 means that the transceiver supports a link length greater than 254 m. A value of zero means that the transceiver does not support copper cables.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.14 |
localModuleVendorSNThis entry describes the vendor's serial number of the transceiver.ro DisplayString .1.3.6.1.4.1.3181.6.4.3.1.15 |
localModuleDateCodeThis entry describes the vendor's date code in the [yymmdd]-format.ro DisplayString .1.3.6.1.4.1.3181.6.4.3.1.16 |
localModuleLaserCurrentThis entry describes the transmitter laser's bias current in milli ampere.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.17 |
localModuleTransmittedPowerThis entry describes the transmitter optical output power in micro watt.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.18 |
localModuleReceivedPowerThis entry describes the transmitter optical received power in micro watt.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.19 |
localModuleLaserTemperatureThis entry describes the laser temperature in degree centigrade.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.20 |
localModuleVoltageThis entry describes the transceiver supply voltage in mV.ro Enumeration .1.3.6.1.4.1.3181.6.4.3.1.21 |
lineModuleTableThis table describes the line module status of the CWDM-system. SEQUENCE OF LineModuleList .1.3.6.1.4.1.3181.6.4.4 |
lineModuleTableEntryAn entry in the line module table. LineModuleList .1.3.6.1.4.1.3181.6.4.4.1 |
lineModuleIdThis entry describes the line module id.ro INTEGER .1.3.6.1.4.1.3181.6.4.4.1.1 |
lineModuleConnectorThis entry describes the connector-type of the port.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.2 |
lineModuleTrCodeSonetThis entry describes the SONET compliance of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.3 |
lineModuleTrCodeGigabitThis entry describes the Gigabit Ethernet compliance of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.4 |
lineModuleTrCodeFbLinkLengthThis entry describes the fibre channel link length of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.5 |
lineModuleTrCodeFbTrTechThis entry describes the fibre channel transmitter technology of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.6 |
lineModuleTrCodeFbTrMediaThis entry describes the fibre channel transmission media of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.7 |
lineModuleTrCodeFbSpeedThis entry describes the fibre channel speed of the transceiver.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.8 |
lineModuleBrNominalThis entry describes the nominal bit rate, specified in units of 100 Megabits per second.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.9 |
lineModuleLength9kmThis entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of kilometers. A value of 255 means that the transceiver supports a link length greater than 254 km. A value of zero means that the transceiver does not support single-mode fibers.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.10 |
lineModuleLength9mThis entry describes the link length supported by the transceiver using single-mode fibers. The value is in units of 100 meters. A value of 255 means that the transceiver supports a link length greater than 25.4 km. A value of zero means that the transceiver does not support single-mode fibers.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.11 |
lineModuleLength50This entry describes the link length supported by the transceiver using 50 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 50 micron multi-mode fibers.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.12 |
lineModuleLength62This entry describes the link length supported by the transceiver using 62.5 micron multi-mode mode fibers. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 62.5 micron multi-mode fibers.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.13 |
lineModuleLengthCopperThis entry describes the link length supported by the transceiver using copper cables. The value is in units of 1 meter. A value of 255 means that the transceiver supports a link length greater than 254 m. A value of zero means that the transceiver does not support copper cables.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.14 |
lineModuleVendorSNThis entry describes the vendor's serial number of the transceiver.ro DisplayString .1.3.6.1.4.1.3181.6.4.4.1.15 |
lineModuleDateCodeThis entry describes the vendor's date code in the [yymmdd]-format.ro DisplayString .1.3.6.1.4.1.3181.6.4.4.1.16 |
lineModuleLaserCurrentThis entry describes the transmitter laser's bias current in milli ampere.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.17 |
lineModuleTransmittedPowerThis entry describes the transmitter optical output power in micro watt.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.18 |
lineModuleReceivedPowerThis entry describes the transmitter optical received power in micro watt.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.19 |
lineModuleLaserTemperatureThis entry describes the laser temperature in degree centigrade.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.20 |
lineModuleVoltageThis entry describes the transceiver supply voltage in mV.ro Enumeration .1.3.6.1.4.1.3181.6.4.4.1.21 |
powerTableThis table describes the power-supply-status of the CWDM-system. SEQUENCE OF PowerList .1.3.6.1.4.1.3181.6.4.5 |
powerTableEntryAn entry in the power-supply table. PowerList .1.3.6.1.4.1.3181.6.4.5.1 |
powerIdThis entry describes the power-supply module id.ro INTEGER .1.3.6.1.4.1.3181.6.4.5.1.1 |
powerArtNoThis entry describes the article number of the power-supply module.ro DisplayString .1.3.6.1.4.1.3181.6.4.5.1.2 |
powerSerNoThis entry describes the serial number of the power-supply module.ro DisplayString .1.3.6.1.4.1.3181.6.4.5.1.3 |
powerDescThis entry provides a detailed description of the power-supply module.ro DisplayString .1.3.6.1.4.1.3181.6.4.5.1.4 |
powerTemperatureThis entry describes the temperature of the power-supply module.ro Enumeration .1.3.6.1.4.1.3181.6.4.5.1.5 |
powerStatusThis entry describes the operational status of the power-supply module.ro Enumeration .1.3.6.1.4.1.3181.6.4.5.1.6 |
powerSuppliedPowerThis entry describes the power output of the power-supply module in watt.ro Enumeration .1.3.6.1.4.1.3181.6.4.5.1.7 |
powerLoadThis entry describes the load level of the power-supply module in percent.ro Enumeration .1.3.6.1.4.1.3181.6.4.5.1.8 |
powerFanStatusThis entry describes the fan status of the power-supply module.ro Enumeration .1.3.6.1.4.1.3181.6.4.5.1.9 |
lineIfTableThis table describes the line-interface status of the CWDM-system. SEQUENCE OF LineIfList .1.3.6.1.4.1.3181.6.4.6 |
lineIfTableEntryAn entry in the line-interface table. LineIfList .1.3.6.1.4.1.3181.6.4.6.1 |
lineIfIdThis entry describes the power-supply module id.ro INTEGER .1.3.6.1.4.1.3181.6.4.6.1.1 |
lineIfArtNoThis entry describes the article number of the power-supply module.ro DisplayString .1.3.6.1.4.1.3181.6.4.6.1.2 |
lineIfSerNoThis entry describes the serial number of the power-supply module.ro DisplayString .1.3.6.1.4.1.3181.6.4.6.1.3 |
lineIfWestLinkStatusThis entry describes the west-link status of the interface module.ro Enumeration .1.3.6.1.4.1.3181.6.4.6.1.4 |
lineIfEastLinkStatusThis entry describes the east-link status of the interface module.ro Enumeration .1.3.6.1.4.1.3181.6.4.6.1.5 |
lineIfWestChannelStatusThis entry describes the west-channel status of the interface module.ro Enumeration .1.3.6.1.4.1.3181.6.4.6.1.6 |
lineIfEastChannelStatusThis entry describes the east-channel status of the interface module.ro Enumeration .1.3.6.1.4.1.3181.6.4.6.1.7 |
lineIfWestLinkRcvPowerThis entry describes the west-link receive power of the interface module in micro watts.ro Enumeration .1.3.6.1.4.1.3181.6.4.6.1.8 |
lineIfEastLinkRcvPowerThis entry describes the east-link receive power of the interface module in micro watts.ro Enumeration .1.3.6.1.4.1.3181.6.4.6.1.9 |
passiveTableThis table describes the passive optical module status of the CWDM-system. SEQUENCE OF PassiveList .1.3.6.1.4.1.3181.6.4.7 |
passiveTableEntryAn entry in the passive table. PassiveList .1.3.6.1.4.1.3181.6.4.7.1 |
passiveIdThis entry describes the passive optical module id.ro INTEGER .1.3.6.1.4.1.3181.6.4.7.1.1 |
passiveArtNoThis entry describes the article number of the power-supply module.ro DisplayString .1.3.6.1.4.1.3181.6.4.7.1.2 |
passiveSerNoThis entry describes the serial number of the power-supply module.ro DisplayString .1.3.6.1.4.1.3181.6.4.7.1.3 |
channelCountThis entry describes the number of channels in the CWDM-system.ro INTEGER .1.3.6.1.4.1.3181.6.4.100 |